This document is the Security Unit Price List for Lease Number 36C25024L0017. It outlines the baseline set of security paragraphs and corresponding unit pricing for the security countermeasures identified in the lease. The Lessor must provide unit prices for all security items, which will be subject to further negotiation prior to issuing the Notice to Proceed for the security improvements. Items designated as "SHELL" or "T.I." are included to align with the full security requirements but should not be priced on this document. The related federal contract opportunity is Solicitation Number 36C25024R0061 for the Martinsville Consolidated Clinic, which requires 10,500 ABOA square feet of contiguous space within a specified area of consideration. The Government is seeking pricing for either a 20-year lease with a 15-year firm term, or a 20-year firm term lease.

View the file

Other files

File Type Posted
36C25024R0061 0005.pdf PDF
36C25024R0061 0004.pdf PDF
36C25024R0061 0003.pdf PDF
Exhibit D- Lease Design Narrative and Room Matrix.pdf PDF
36C25024R0061 0002.pdf PDF
36C25024R0061 0001.docx DOCX document
Exhibit H - Tenant Improvement Cost Summary_TICS Table.xlsx XLSX spreadsheet
Exhibit R - Past Performance Survey.pdf PDF
Exhibit P- Seismic Offer Forms.pdf PDF
Exhibit F- VA Secutiry Requirements for FSL II.pdf PDF
Exhibit T -527 Contract Qualifications.pdf PDF
Exhibit A- Lease No 36C25024L0017.docx DOCX document
Exhibit L-GSA Form 1217 Lessor A-Cost Statement.pdf PDF
Exhibit I-3516 Solicitation Provisions.pdf PDF
Exhibit C- Conceptual Layout.pdf PDF
Exhibit M-GSA12000.pdf PDF
Exhibit J- 3517B General Clauses.pdf PDF
Exhibit B-ASR Martinsville Rev02.docx DOCX document
Exhibit D- Lease Design Narrative.docx DOCX document
Exhibit V- Operation and Maintenance Plan_Sample.docx DOCX document
Exhibit Q- Wage Determination.pdf PDF
Exhibit E- HVAC_IT Requirments and Design Guide.pdf PDF
Exhibit N - FAR 52.204-24 Representation Regarding Certain Telecommunications and Video Surveillance Services or Equipment.pdf PDF
Exhibit S-Pre-Proposal Conference Registration Form.docx DOCX document
36C25024R0061- Request for Lease Proposal Martinsville CBOC.docx DOCX document
Exhibit K-Form 1364 Proposal to Lease Space.pdf PDF
Exhibit U- Offering Entity Acknowledgement Form.docx DOCX document
Exhibit O - SF330 A-E Qualifications.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INSTRUCTIONS TO THE LEASING SPECIALISTS: THIS SPREADSHEET REFLECTS THE BASELINE SET OF SECURITY

PARAGRAPHS. EACH PARAGRAPH IN THE SECURITY SECTION WILL HAVE A CORRESPONDING LINE. IF THE SECURITY

SECTION IS ADJUSTED BY ADDING OR DELETING PARAGRAPHS THE SPREADSHEET MUST BE CHANGED

ACCORDINGLY.

SECURITY UNIT PRICE LIST (FSL II)

LEASE NUMBER 36C25024L0017

[INSERT DATE]

[INSERT CLIENT NAME]

[INSERT CITY and STATE]

To be filled out post-award

The Building Specific Amortized Capital (BSAC) amount under the Lease represents an estimate of the possible countermeasures outlined under the Security

Requirements section of the lease. The actual BSAC amount shall be determined after the final design. Using this form, the Lessor shall quote unit prices on all security countermeasures identified in the Lease, as reflected in the final Design Intent Drawings (DIDs) and Construction Documents (CDs). These unit costs shall be subject to further negotiation, prior to issuance of a 'Notice To Proceed' for the security improvements. Refer to 'Security Standards' attachment to the Lease for additional details. Input 'Unit Price' and 'Quantity' figures for BSAC items (light blue) and the total will automatically be calculated for that row. Items designated as

'SHELL' or 'T.I.' are included on this form to align with the full requirements of the 'Security Standards' attachment, but should not be priced on this document. SHELL and T.I. costs should be included on a 'TICS' form if one has been provided by the Government.

Lease Security Standards Section Unit Price Quantity Total

FACILITY ENTRANCES, LOBBY, COMMON AREAS, NON-

I.

PUBLIC, AND UTILITY AREAS

A. FACILITY ENTRANCES AND LOBBY

1. EMPLOYEE ACCESS CONTROL AT ENTRANCES (SHELL) Priced in Shell

B. SCREENING REQUIREMENTS

1. ACCOMODATION OF RETAIL/MIXED USE SPACE (SHELL) Priced in Shell

C. COMMON AREAS, NON-PUBLIC, AND UTILITY AREAS

1. PUBLIC RESTROOM ACCESS (SHELL) Priced in Shell

2. SECURING CRITICAL AREAS (SHELL) Priced in Shell

3. VISITOR ACCESS CONTROL (SHELL) Priced in Shell

PUBLIC SPACE RESTRICTIONS WITH PRIMARY VERTICAL LOAD

4.

MEMBERS

RESTRICT CONTACT FROM PUBLIC AREAS WITH PRIMARY VERTICAL

4a.

LOAD MEMBERS

RESTRICT CONTACT FROM MAIL AREAS WITH PRIMARY VERTICAL LOAD

4b.

MEMBERS

II. INTERIOR (GOVERNMENT SPACE)

A. IDENTITY VERIFICATION (SHELL) Priced in Shell

B FORMAL KEY CONTROL PROGRAM (SHELL) Priced in Shell

III. SITES AND EXTERIOR OF THE BUILDING

A. SIGNAGE

1.

POSTING OF SIGNAGE IDENTIFYING THE SPACE AS GOVERNMENTAL

(SHELL)

Priced in Shell

2. POSTING OF REGULATORY SIGNAGE (SHELL) Priced in Shell

B. LANDSCAPING AND ENTRANCES

1. LANDSCAPING REQUIREMENTS (SHELL) Priced in Shell

Security Unit Price List (Level II)

REV (06 2022)

VHACLEButleD Cross-Out

2. HAZMAT STORAGE (SHELL) Priced in Shell

3. PLACEMENT OF RECEPTACLES, CONTAINERS, AND MAILBOXES (SHELL) Priced in Shell

C. PARKING

1. PUBLIC ACCESS TO GOVERNMENT PARKING AREAS (SHELL) Priced in Shell

IV. SECURITY SYSTEMS

A. SECURITY SYSTEM TESTING & MAINTENANCE CRITERIA $ -

B. VIDEO SURVEILLANCE SYSTEM (VSS)

LESSOR PROVIDED DESIGN, INSTALLATION, AND MAINTENANCE $ -

GOVERNMENT PROVIDED SCOPE, PRODUCT, INSTALLATION, AND

MAINTENANCE

Government Provided

C. INTRUSION DETECTION SYSTEM

LESSOR PROVIDED DESIGN, INSTALLATION, AND MAINTENANCE $ -

GOVERNMENT PROVIDED SCOPE, PRODUCT, INSTALLATION, AND

MAINTENANCE

Government Provided

D. DURESS ALARM

LESSOR PROVIDED DESIGN, INSTALLATION, AND MAINTENANCE $ -

GOVERNMENT PROVIDED SCOPE, PRODUCT, INSTALLATION, AND

MAINTENANCE

Government Provided

E. SECURITY SYSTEMS DESIGN $ -

V. STRUCTURE

A. WINDOWS

LOCK GROUND FLOOR WINDOWS (BSAC- IDS Monitoring) $ -

B. BUILDING SYSTEMS

1. EMERGENCY GENERATOR PROTECTION (T.I.) Priced in Tenant Improvements

2. SECURE AIR INTAKE GRILLES $ -

VI. OPERATIONS AND ADMINISTRATION

A. FACILITY SECURITY COMMITTEE (FSC) - (SHELL *) Priced in Shell

B. ACCESS TO BUILDING INFORMATION (SHELL *) Priced in Shell

C. CONSTRUCTION SECURITY PLAN (SHELL) Priced in Shell

VII. CYBERSECURITY (SHELL *)

CYBERSECURITY REQUIREMENTS OUTLINED IN SECTIONS A-C (SHELL *) Priced in Shell

TOTAL COSTS $ -

Security Unit Price List (Level II)

REV (06 2022)

File details come from the government source that posted it. Updated .