EXHIBIT_E_-_MOLD_INSPECTION_REPORTCOOK_1_cbf5cb4e_1.pdf

PDF 2 MB Posted

Attached to
Residential Rehabilitation - Cook
Solicitation number
RFQ-CDS/251022
Issued by
Marion County, Orlando City, Florida

About this file

This is a mold assessment report prepared by DK Environmental & Construction Services, Inc. for the City of Ocala, Florida regarding a residential property located at 1560 NW 14th Street, Ocala, FL 34475. The assessment was conducted on April 19, 2024 by licensed Florida Mold Assessor Chris Ritko (MRSA2640) and includes air sampling, surface sampling, thermal imaging inspection, and moisture content analysis. The inspection identified visible microbial growth, elevated spore counts in interior air samples, and elevated moisture content in multiple areas including the kitchen (42.5%), southwest bedroom (94.0% and 88.7%), west bathroom (80.7%), and east bathroom (60.5%). The suspected cause of loss is attributed to plumbing system leaks that have not yet been repaired. Remediation is required in the kitchen, southwest bedroom, west bathroom, east bathroom, laundry room, general living areas, and HVAC systems, with recommendations to follow IICRC S520 mold remediation standards and include negative pressure containment, removal of affected materials, application of EPA-registered mold-resistant coatings, and post-remediation clearance verification by a Florida-licensed mold assessor.

Laboratory analysis conducted by EMSL Analytical, Inc. revealed that interior air samples contained significantly elevated Aspergillus/Penicillium spore counts (2,900 spores/m³ in the kitchen and 870 spores/m³ in the southwest bedroom) compared to the exterior baseline sample (870 spores/m³), indicating conditions unsafe for human occupancy. Surface tape samples from affected areas showed high levels of Aspergillus, Cladosporium, and Scopulariopsis/Microascus species. The report emphasizes that interior air quality must equal or be less than exterior air quality to be safe for occupancy and recommends correcting all moisture conditions prior to remediation, maintaining relative humidity between 30-60%, utilizing Florida-licensed remediators with proper certifications and insurance, and implementing proper containment with HEPA filtration and negative air pressure during all remedial activities. The assessment concludes that all visible mold growth should be remediated regardless of visible square footage due to the potential for hidden damage and cross-contamination risks.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

2024 DK Environmental & Construction Services, Inc. All rights reserved.

MOLD ASSESSMENT REPORT

PREPARED FOR THE FOLLOWING PROPERTY:

Sabrina & Kerry Cook 1560 NW 14th Street

Ocala, FL 34475 352-239-4108

PERFORMED ON:

April 19, 2024

PERFORMED AND PREPARED BY:

Chris Ritko Licensed Florida Mold Assessor

MRSA2640

8786 Sonoma Coast Drive, Winter Garden, FL 34787 (407)614-4572 Office (814)243-1927 Cell dkenvironmental@yahoo.com www.dk-environmental.com

TABLE OF CONTENTS

I. Introduction

II. Scope of Work & Methods

III. Summary of Physical Analysis

IV. Summary of Laboratory Analysis

V. Protocols

1. Summary of Areas Requiring Remediation

2. Remediation Process

VI. General Recommendations

VII. In Closing

VIII. Site Photographs

IX. Site Plan

X. Definitions

XI. References

XII. Licensing

XIII. Laboratory Analysis Report

Confidentiality Notice: This Mold Inspection Report is intended only for the use of the individual or entity addressed, and may contain information that is privileged, confidential, and exempt from disclosure under applicable law. If you are not the intended recipient or responsible for delivering this report to the intended recipient, you are hereby notified that any dissemination, distribution, or copying of this report, in whole or in part, is prohibited. If you have received this report in error, please notify us immediately. Thank you.

I. INTRODUCTION

DK Environmental & Construction Services, Inc. (DKE) conducted a preliminary non-intrusive mold assessment of the accessible living spaces of the Interior inspected area(s) of the property, and has prepared this report summarizing our assessment findings and laboratory results. Air and surface sampling were performed in Interior inspected area(s) of the property, along with one (1) Exterior baseline/control air sample.

The purpose of this assessment was to identify the presence or absence of mold growth and conditions conducive to mold growth, and to determine the Interior air quality as it relates to mold. Information obtained through visual inspection and microscopic analysis of air sampling was used to determine the property�s interior conditions. DKE follows the

Indoor Environmental Standards Organization (IESO) sampling protocols.

The following is a summary of this inspection�s findings:

Visible microbial growth was observed in Interior inspected area(s) of the property.

Interior air sample(s) was/were found to contain elevated spore counts.

Surface sample(s) taken in Interior inspected area(s) of the property was/were found to contain elevated spore counts.

Mold remediation is recommended and outlined in the �Protocols� section of this report.

An explanation of the above-listed summary can be found in this report. If you have any questions after reviewing this report, please call us at 407-614-4572.

II. SCOPE OF WORK & METHODS

Non-Intrusive Visual Inspection:

A visual inspection with the use of a FLIR E6 infrared thermal imaging camera and a FLIR MR77 moisture meter was performed in the Interior inspected area(s) of the property to identify suspect conditions and potential moisture source locations. Digital and infrared photographs were taken as necessary to support inspection findings.

Air Sampling and Analysis:

Air samples were collected in Interior inspected area(s) of the property to determine indoor air quality relating to microbial contamination using Buck BioAire Model B520 Sampling Pumps with Allergenco D Spore Traps. The samples were collected for a five-minute period with a calibrated flow rate of 15 liters per minute for a total sample of 75 liters in accordance with the manufacturer�s recommendations.

The Allergenco D Spore Trap is a sampling device designed for the rapid collection and quantitative analysis of a wide range of airborne aerosols. It collects non-viable particulate such as mold spores, pollen, insect parts, skin cell fragments, fibers (asbestos, fiberglass, cellulose, etc.) and inorganic particles.

The air sampling methodology utilized for this project was designed to quantify the respective airborne presence of fungal spores in the Interior living spaces in relationship to what is naturally occurring outdoors, commonly referred to as normal fungal ecology.

Air sampling was performed in Interior inspected area(s) of the property. One (1) Exterior baseline/control air sample was collected for comparison purposes. After sample collection the cassettes were re-sealed delivered to a third-party independent laboratory for direct microscopic examination. There, a microbiologist examined the slides to identify the type, and determine the airborne concentration of, fungal spores present. Spore identification is to genus level unless otherwise specified.

III. SUMMARY OF PHYSICAL ANALYSIS

Inspection activities performed by DKE indicate the following conditions at the property, as existing at the time and date of sample collection and observations:

Exterior/Interior Temperature and Relative Humidity:

Exterior Weather Conditions Exterior Temperature (F) Exterior Relative Humidity (%) Sunny, mild wind 70.8 63.3

ASHRAE (American Society of Heating, Refrigerating and Air Conditioning Engineers) recommends an indoor temperature of 68.5F - 76.5F, and an indoor relative humidity level of 30% - 60%. The following table lists the relevant conditions observed during the inspection:

Interior Room Name Temperature (F) Relative Humidity (%) Interior Inspected Area(s) 77.0 69.8

Levels that fall outside of recommended parameters are identified in red.

Microbial Airborne Activity:

One (1) Exterior baseline/control air sample was collected in the same manner as Interior air sample(s). As of this writing, no government agencies have determined the amount of mold spores a person can be exposed to before health problems occur.

Interior air quality should be �equal to or less than� the Exterior air quality in order to be safe for human occupancy. Please see the �Summary of Laboratory Analysis� and

�Laboratory Analysis Report� for air sampling results.

PROPERTY INTERIOR

Cause of Loss:

Client-Defined Suspected Cause of Loss Has Been Repaired?

Plumbing system leaks No

Please see the �Site Photographs� section in this report for the specific locations of impacted surfaces and substrates, if any, documented below:

Microbial Surface Activity:

Suspected microbial growth was observed on building components in Interior inspected area(s) of the property. Surface sampling was taken of suspected growth for identification purposes.

Visual Inspection:

Visible water damage was observed on building components in Interior inspected area(s) of the property.

Elevated Moisture Content:

Interior Room Name Drying Standard Location Moisture Content (%) Kitchen >15% South lower wood exposed framing 42.5

Southwest Bedroom >15% Northwest lower drywall wall 94.0 Southwest Bedroom >15% Northwest vinyl flooring 88.7

West Bathroom >15% West upper drywall wall 80.7 East Bathroom >15% West lower drywall wall 60.5

Levels that fall outside of recommended parameters are identified in red.

Note: It is generally accepted that wood rots when it contains 15% or greater moisture content (MC). Therefore, a reading at or above 15% MC in any organic building material indicates a hazardous condition which should be investigated further. Generally, moisture content below 15% inhibits growth of both destructive fungi and surface fungi.

IV. SUMMARY OF LABORATORY ANALYSIS

Airborne Mold Spores by Spore Trap Technique and/or Surface Sampling by Tape/Swab

Sample Number

Location Elevated Fungal Species

Spores/M3*

Aspergillus/Penicillium 870

Allergenco D Spore Trap 5576221

Exterior North Wall Baseline/Control Sample Collected at Breathing Level

Total Spore Count/M3 10490

Aspergillus/Penicillium 2900

5576210

Interior Kitchen Preliminary Sample

Total Spore Count/M3 3570

5576202

Interior Southwest Bedroom Preliminary Sample

Total Spore Count/M3 1350

Aspergillus High

Bio-Tape 1560-1

Interior Kitchen Preliminary Sample Collected from South lower wood wall cavity Total Spore Count/M3 >1000

Aspergillus/Penicillium Low Cladosporium High Scopulariopsis/Microascus Medium Scolecobasidium Low

Bio-Tape 1560-2

Interior Southwest Bedroom Preliminary Sample Collected from Northwest wood baseboard

Total Spore Count/M3 >1000

Aspergillus/Penicillium Low

Bio-Tape 1560-3

Interior East Bathroom Preliminary Sample Collected from Southwest wood baseboard Total Spore Count/M3 11 - 100

*Spores/M3 results listed in red represent levels significantly higher than outside air (Spore Trap), or a �Heavy� or �Very Heavy� spore estimate (Tape or Swab).

Please refer to the �Laboratory Analysis Report� for further interpretation of these results.

Interior air sample(s) was/were found to contain elevated spore counts.

Surface sample(s) taken in Interior inspected area(s) of the property was/were found to contain elevated spore counts.

According to Florida Title XXXII, Part XVI, ss. 468.84-468.8424, mold assessment and remediation need not be performed by Florida-licensed assessors and remediators if the mold-affected area is less than or equal to 10 square feet. However, due to the possibility of identifying additional mold-affected square footage during the remediation process, as well as the potential for cross-contamination due to improper remediation techniques, inadequate containment, etc., DKE recommends the use of Florida-licensed mold assessors and remediators for the assessment, remediation, and post-remediation verification for all mold projects, regardless of visible square footage.

As of this writing, no government agencies have determined the amount of mold spores a person can be exposed to before health problems occur. The indoor air quality should be �equal to or less than� the outside air quality in order to be safe for human occupancy.

Air sample results indicating a non-elevated spore concentration should not be construed as a guarantee or warranty against current or future microbial growth.

Laboratory results are reflective of air quality conditions in Interior inspected area(s) of the property as they specifically relate to airborne fungal spores at the time of sample collection. Air sample collection provides a �snapshot� in time as to what is occurring in the air at the time of sample collection. Any condition that allows for the loss of moisture control, including but not limited to: water intrusion, water vapor condensation, or prolonged elevated indoor humidity (>60%) may result in microbial growth.

V. PROTOCOLS

Please refer to the �General Recommendations� section of this report when implementing these protocols.

The contractor performing this work should develop a detailed remediation plan to implement this protocol.

The following protocol guidelines are guidelines only. They can be modified, with approval of the environmental consultant, if it is believed the modifications will achieve the same or greater levels of worker and environmental protection and expedite remediation. This Protocol is not intended to be a detailed step-by-step outline of how to perform mold remediation. Rather, its purpose is to provide a general outline of how such projects should be handled. Work zones are often expanded based on the extent of �hidden damage" that is exposed when opening wall cavities, removing cabinetry, etc.

The remediation contractor is solely responsible for protection of health, safety, and the environment at the job site. The remediation contractor is solely responsible for all required training and licensure related to any work covered by this Mold Remediation Protocol. The remediation contractor shall re-clean at his expense if the post remediation samples fail or if the final visual inspection fails. This process of re-cleaning shall continue at the contractor's expense until a successful post remediation evaluation is achieved.

This section shall not be applicable if there are special or unusual contamination conditions discovered during the remediation activities that would substantially change or affect the post-remediation evaluation.

1. SUMMARY OF AREAS REQUIRING REMEDIATION/REPAIR

Interior Kitchen

Interior Southwest Bedroom

Interior West Bathroom

Interior East Bathroom

Interior Laundry Room (If Applicable)

Interior Living Areas (General)

HVAC System(s)

2. REMEDIATION PROCESS

Seal off all areas of the property where remediation will occur with 6-mil plastic by use of a negative air pressure containment system. This system should isolate the work area and prevent the migration of contaminants to the unaffected areas of the property.

The Remediation Plan should detail how entry and exit from containment will be accomplished without spreading contaminant.

Isolate the HVAC system from the work area to minimize the risk of cross contamination. Use portable dehumidification as necessary during the remediation process.

Seal and protect contents with 6-mil plastic to prevent cross contamination in the property.

Install an adequate number of HEPA air scrubbers in the affected area to remove airborne spores/particles and to further isolate the environment.

As dust and debris is generated, it should be immediately cleaned up using HEPA vacuums or other appropriate methods.

INTERIOR KITCHEN

Remove, clean, cover, and store countertop, sink, and fixtures for post-remediation reinstallation, if applicable.

Remove all affected lower wood cabinetry components.

Remove all affected drywall. Drywall should be removed to a minimum of two feet (2�) from floor level. This height may increase depending on the scope of affected areas discovered during the remediation process.

Properly bag and dispose of all contaminated waste materials.

Clean, treat, and encapsulate all newly-exposed framing components and wood wall cavity with two coats of an EPA-registered mold resistant coating to prevent mold growth, if applicable. Remove all affected framing components and wood wall cavity that cannot be adequately cleaned/treated.

INTERIOR SOUTHWEST BEDROOM

Remove all affected wood baseboard.

Remove all affected drywall. Drywall should be removed to a minimum of two feet (2�) from floor level. This height may increase depending on the scope of affected areas discovered during the remediation process.

Remove all affected vinyl flooring, if applicable.

Properly bag and dispose of all contaminated waste materials.

Treat and encapsulate all newly-exposed framing components with two coats of an EPA-registered mold resistant coating to prevent mold growth, if applicable.

Treat and encapsulate any newly-exposed sub-flooring with two coats of an EPA-registered mold resistant coating to prevent mold growth, if applicable.

INTERIOR WEST BATRHOOM

Clean/treat all affected drywall ceiling and wall. Remove all affected drywall that cannot be adequately cleaned/treated.

Properly bag and dispose of all contaminated waste materials.

Treat and encapsulate any newly-exposed framing components with two coats of an EPA-registered mold resistant coating to prevent mold growth, if applicable.

Inspection/repair of the plumbing systems by a licensed and insured plumbing contractor is recommended.

INTERIOR EAST BATHROOM

Remove all affected wood baseboard.

Remove all affected drywall. Drywall should be removed to a minimum of two feet (2�) from floor level. This height may increase depending on the scope of affected areas discovered during the remediation process.

Properly bag and dispose of all contaminated waste materials.

Treat and encapsulate all newly-exposed framing components with two coats of an EPA-registered mold resistant coating to prevent mold growth, if applicable.

Inspection/repair of the plumbing systems by a licensed and insured plumbing contractor is recommended.

INTERIOR LAUNDRY ROOM (IF APPLICABLE)

Remove all affected wood baseboard.

Remove all affected drywall. Drywall should be removed to a minimum of two feet (2�) from floor level. This height may increase depending on the scope of affected areas discovered during the remediation process.

Remove all affected vinyl flooring, if applicable.

Properly bag and dispose of all contaminated waste materials.

Treat and encapsulate any newly-exposed framing components with two coats of an EPA-registered mold resistant coating to prevent mold growth, if applicable.

Treat and encapsulate any newly-exposed sub-flooring with two coats of an EPA-registered mold resistant coating to prevent mold growth, if applicable.

INTERIOR LIVING AREAS (GENERAL)

Clean, scrub, and disinfect all affected areas and contents (walls, ceilings, flooring, closets, baseboard, trim, shelving, picture frames, household goods, clothing, furniture, cabinetry, electronics, appliances, ceiling fans/lights, door components, window components, etc.) within the applicable Interior Living Areas, as necessary, with an EPA-registered antimicrobial/antifungal disinfectant. All components/contents that cannot be adequately treated should be removed/disposed of.

HVAC SYSTEM(S)

Inspection and cleaning of the HVAC system(s), including air handler(s), ductwork, vents, filters, exhaust systems, etc., by a licensed and insured HVAC contractor is recommended.

Post-remediation clearance evaluation should be performed by a Florida-licensed Mold Assessor.

Following post-remediation clearance evaluation, disassemble and bag containment materials. Dispose of containment materials according to proper disposal protocol.

End of Section

VI. GENERAL RECOMMENDATIONS

This report only provides an evaluation of the interior substrate conditions and indoor air quality as they relate to mold and moisture. The following recommendations are meant to provide general remediation procedures based on nationally-accepted standards.

These recommendations should not be construed as the only effective methodology for remediation and no warranty is expressed or implied with these recommendations. DKE is independent of any remediation process, and we defer to the qualified remediator for specific repair protocols since the actual remediation process may expose additional areas requiring treatment.

The goal of the remediation process is to correct all existing moisture conditions that promote mold growth, and to physically remove all mold contaminated/non-restorable materials in accordance with the IICRC S520 mold remediation standard.

Prior to any remediation, always correct all conditions that have contributed to excess moisture or humidity at the property. Extract any excess water from the property, and remove excess humidity with a professional-grade dehumdifier. Relative humidity must be maintained between 30% - 60% in the work area.

We recommend Florida-licensed mold remediators with ACAC and/or IICRC certified personnel who are experienced with water damage and microbial remediation solutions perform all remedial activities including intrusive investigation. The remediation company should show proof of licensing/certification, carry mold-specific Errors & Omissions Insurance, General Liability Insurance and Worker�s Compensation.

All remediation workers should be properly licensed/certified. Adequate personal protective equipment (PPE) must be worn when engaging in mold remediation activities.

This PPE should include, but is not limited to, N95 respirators, disposable coveralls, non-vented eye goggles, and rubber gloves that extend to mid-forearm.

Any and all water damaged/mold impacted areas should be in containment. These areas should be sealed off using 6-mil plastic under a negative pressure with the use of negative air machines (NAMs) equipped with high-efficiency particulate air (HEPA) filtration during remedial efforts to prevent potential cross-contamination between the affected and unaffected areas.

The HVAC system should be isolated from the work area to minimize the risk of cross contamination. Portable dehumidification may be necessary during the remediation process to maintain conditions that will not support additional mold growth.

Any and all roofing system inspection and work should be performed by a licensed and insured roofing contractor.

Any and all HVAC system inspection and work should be performed by a licensed and insured HVAC contractor.

All exterior sprinkler system and downspout discharge should be directed away from property walls/foundations.

Intrusive investigation should be performed by qualified persons in areas with water damage and/or elevated moisture content to identify the full extent of areas requiring remedial treatment.

Areas of water damaged and/or stained carpeting that cannot be adequately dried and cleaned should be discarded. Areas of carpet pads that have been wet should always be discarded.

Areas of wet/water-damaged insulation should be removed.

Porous building materials (sheetrock, baseboards, tack strips, etc.) that have been water damaged to the point that drying and cleaning will not restore them to their pre-water exposure condition or have sustained loss of integrity should be removed and discarded, whether or not there is visible evidence of fungal growth.

All non-porous materials and wood surfaces that show visible signs of mold must be cleaned. Sand or use a wire brush on all mold-contaminated surfaces and then wipe the area with disposable wipes. Scrub all mold-contaminated surfaces using a damp cloth and detergent solution until all mold has been removed. Rinse cleaned surfaces with clean water.

Non-removable, contaminated wood structural supports must be sanded down at least 1/16th of an inch to remove mold prior to fungicidal treatment. Contaminated metal studs must be cleaned with a detergent solution and treated with fungicide. If it is not possible to clean and disinfect the structural item, then it must be removed, disposed of and replaced. Structural supporting members may need the consultation of a structural engineer prior to removal and replacement. Sand or wipe away mold from the top, bottom, front, back, and sides of items. This approach to covering all surfaces must also be utilized when applying fungicide.

All visible fungi must be physically removed. Areas that have developed fungal growth should be HEPA vacuumed and cleaned thoroughly with an EPA registered product.

However, if the mold growth is imbedded within the material and cannot be cleaned, removal of the contaminated materials plus an additional three (3) feet of material beyond the affected area(s) should also be removed and disposed of.

Contaminated building materials should be removed carefully in as large a section as possible for bagging or wrapping with 6-mil disposal bags or securely wrapped in 6-mil poly sheeting. Bagged materials should be sealed inside a second bag before moving them outside the containment area (double bagging), if they are going to pass through Condition 1 areas.

All surfaces within the containment should be HEPA vacuumed, damp-wiped with an appropriate EPA registered product, and HEPA vacuumed again.

Post-remediation verification should be performed by a licensed Mold Assessor prior to any build-back of finish materials.

VII. IN CLOSING

In closing, DKE strongly recommends that any and all biological remediation be conducted following guidelines established by the Institute of Inspection Cleaning and Restoration (IICRC). Their document entitled IICRC S520 Standard and Reference Guide for Professional Mold Remediation outlines work practices and equipment to be utilized during the remediation procedure. Also follow recommendations outlined in the US EPA: Mold Remediation in Schools and Commercial Buildings, Publication EPA 402-K-01-001.

It is important to note that our findings relating to physical conditions observed during this assessment were not intended nor do they attempt to identify every possible source of contamination, mold or otherwise, in the structure. The assessor is neither insurer nor guarantor against water problems, mold problems or other defects in the subject property or any of its components.

Any measured results, analysis data and/or physical observations made are valid only for the period in which this inspection was conducted. Any additional degradation of building materials or contamination from new or reactivated sources or areas inaccessible at the time of the inspection is not the responsibility of DKE.

Historical events or ambient air conditions that may have existed prior to this inspection cannot be correlated in any way with the enclosed data. No warranty, real or implied, is made as to what was or is the exact cause or source that may have adversely affected the indoor air quality.

If you have any questions after reviewing this report, please call us at 407-614-4572.

We are happy to help as your good health and comfort is our goal.

Thank You, Debra Koontz, President DK Environmental & Construction Services, Inc.

VIII. SITE PHOTOGRAPHS

Calibration prior to testing Exterior North wall baseline

Interior Kitchen sample Interior Kitchen Lower wood sink cabinetry Visible water damage Visible microbial growth

Interior Kitchen Interior Kitchen South lower wood framing, wall cavity South lower wood framing Visible water damage Elevated moisture content (42.2%)

Interior Southwest Bedroom Interior Southwest Bedroom Northwest lower drywall, wood baseboard Northwest lower drywall Visible water damage, standing water Elevated moisture content (94.0%)

Interior Southwest Bedroom Interior West Bathroom Northwest vinyl flooring West upper drywall wall, ceiling Elevated moisture content (88.7%) Visible microbial growth

Interior West Bathroom Interior East Bathroom West upper drywall wall West lower drywall, wood baseboard Elevated moisture content (80.7%) Visible water damage

Interior East Bathroom West lower drywall Elevated moisture content (60.5%)

IX. SITE PLAN

X. DEFINITIONS

Airborne: supported especially by aerodynamic forces or propelled through the air by force.

Air filtration device (AFD): depending on the mode of use, an AFD that filters (usually HEPA) and recirculates air is referred to as an air scrubber. One that filters air and creates negative pressure is referred to as a negative air machine (NAM).

Allergens: substances that act as antigens producing an allergy.

Assessment: a process performed by an indoor environmental professional (IEP) that includes the evaluation of data obtained from a building history and inspection to formulate an initial hypothesis about the origin, identity, location and extent of amplification of mold contamination. If necessary, a sampling plan is developed, and samples are collected and sent to a qualified laboratory for analysis. The subsequent data is interpreted by the IEP. Then, the IEP, or other qualified individual, may develop a remediation plan.

Condition 1 (normal fungal ecology): an indoor environment that may have settled spores, fungal fragments or traces of actual growth whose identity, location and quantity are reflective of a normal fungal ecology for a similar indoor environment.

Condition 2 (settled spores): an indoor environment which is primarily contaminated with settled spores that were dispersed directly or indirectly from a Condition 3 area, and which may have traces of actual growth.

Condition 3 (actual growth): an indoor environment contaminated with the presence of actual mold growth and associated spores. Actual growth includes growth that is active or dormant, visible or hidden.

Containment: a precaution used to minimize cross-contamination from affected to unaffected areas by traffic or material handling. Containment normally consists of 6-mil polyethylene sheeting, often in combination with negative air pressure, to prevent cross-contamination.

Contaminated (contamination): the presence of indoor mold growth or mold spores, whose identity, location and quantity are not reflective of a normal fungal ecology for similar indoor environments, and which may produce adverse health effects, cause damage to materials or adversely affect the operation or function of building systems.

Cross-contamination: the spread of a source or sources of contamination from an affected area to an unaffected area.

Dew Point Temperature: the temperature at which water vapor begins, or would begin, to condense.

Fungus (plural �fungi�): one of the kingdoms into which living things are categorized.

Fungi have distinct nuclei and include a variety of types, such as molds, yeasts, and mushrooms.

Genus: a taxonomic category ranking below a family and above a species.

HEPA: an acronym for �high efficiency particulate air/arrestance�, which describes an air filter that removes 99.97% of particles at 0.3 microns in diameter.

HVAC: an acronym for Heating, Ventilation, and Air Conditioning.

Indoor Environmental Professional (IEP): an individual who is qualified by knowledge, skill, education, training, certification and experience to perform an assessment of the fungal ecology of structures, systems and contents at a job site, create a sampling strategy, sample the indoor environment and submit to an appropriate laboratory, interpret laboratory data and determine Condition 1, 2, or 3 for the purpose of establishing a scope of work and verifying the return of the job site to Condition 1.

Inspection: the gathering of information regarding the mold and moisture status of the building, system, contents or area in question.

Materially-interested parties: an individual or entity substantially and directly affected by a mold remediation project.

MERV: MERV is an acronym for Minimum Efficiency Reporting Value. The MERV rating is a measure of the minimum efficiency of an air filter when dealing with particulate sizes between 0.3 to 10 microns.

Micron: one-millionth of a meter - also known as a micrometer.

Mold: a group of microscopic organisms that are part of the Fungi Kingdom. They generally reproduce by means of spores and are ubiquitous. Often, the terms mold and fungi are used interchangeably.

MVOC�s: Microbial Volatile Organic Compounds - Some compounds produced by molds are volatile and are released directly into the air.

Mycelium: the vegetative part of a fungus consisting of a mass of branching threadlike structures.

Mycotoxin: Toxic compounds produced by certain fungi. Some mycotoxins cling to the surface of mold spores; others may be found within spores. More than 200 mycotoxins have been identified from common molds, and many more remain to be identified.

Normal fungal ecology (Condition 1): an indoor environment that may have settled spores, fungal fragments or traces of actual growth whose identity, location and quantity are reflective of a normal fungal ecology for a similar indoor environment.

Pathogenic: causing or capable of causing disease.

Personal protective equipment (PPE): safety items designed to prevent exposure to potential hazards. Examples include: respirators, gloves, goggles, protective clothing and tools.

Plenum: an air-filled space in a structure that receives air from a blower for distribution (as in a ventilation system).

Post-remediation verification: an inspection and assessment performed by an IEP after a remediation project, which can include visual inspection, odor detection, analytical testing or environmental sampling methodologies to verify that structure, system or contents have been returned to Condition 1.

Preliminary determination: a conclusion drawn from the collection, analysis and summary of information obtained during an initial inspection and evaluation to identify areas of moisture and actual or potential mold growth.

Quality control: activities performed by a remediator that are designed to assure the effectiveness of the advised or suggested.

Relative Humidity: The ratio of the amount of water in the air at a given temperature to the maximum amount it could hold at that temperature; expressed as a percentage.

Remediate: the process of restoring, repairing; regarding mold damage in buildings.

The process includes removing damaged materials, replacing them with new materials and correcting the problem(s) that caused the damage.

Spores: the reproductive elements of lower organisms, such as fungi.

Threshold Exposure Limits: Threshold exposure limits for fungal air contaminants for individual occupants have not been established, and because of other factors that affect the exposure levels independent of area (proximity, duration), it is impossible to say with certainty how small an area of visible mold growth is small enough to ignore. It is recommended, therefore, that all visible growth be remediated regardless of area.

Toxicity: the degree to which something is poisonous.

Toxinogenic: toxin-producing fungi or bacteria.

Viable: capable of germination and growth.

Volatile Organic Compounds (VOC�s): chemicals which vaporize at room temperature.

XI. REFERENCES

IICRC S520: Standard and Reference Guide for Professional Mold Remediation 3rd Edition. Institution of Inspection, Cleaning and Restoration Certification. Vancouver, WA. 2015

IICRC S500: Standard and Reference Guide for Professional Water Damage Restoration 4th Edition. Institution of Inspection, Cleaning and Restoration Certification.

Vancouver, WA. 2021

Recognition, Evaluation and Control of Indoor Mold. American Industrial Hygiene Association. Fairfax, Va. 2008

Fungal Contamination: A Manual for Investigation, Remediation and Control. Hollace S. Bailey, PE, CIAQP, CIE, CMR. Building Environment Consultants, Inc. Jupiter, FL.

Bioaerosols: Assessment and Control. Janet Macher, ScD., M.P.H. American Conference of Governmental Industrial Hygienists, Cincinnati, OH. 1998

Worldwide Exposure Standards for Mold and Bacteria. 8th Edition. Robert C. Brandys, PhD, MPH, PE, CIH, CSP, CMR and Gail M. Brandys, MS, CSP, CMR, CIEC. OEHCS Publications. Hinsdale, IL. 2010

Post-Remediation Verification and Clearance Testing for Mold and Bacteria � Risk Based Levels of Cleanliness Assurance 5th Edition. Robert C. Brandys, PhD, MPH, PE, CIH, CSP, CMR and Gail M. Brandys, MS, CSP, CMR, CIEC. OEHCS Publications.

Hinsdale, IL.

XII. LICENSING

8786 Sonoma Coast Drive

Winter Garden, FL 34787

Phone:814-243-1927

DK Environmental

Prepared Exclusively For

EXPANDED FUNGAL REPORT TM

AIHA LAP, LLCEMLAP #163563

AIHA LAP, LLC.

Report Date: 4/22/2024

1560 NW 14th Street Ocala, FL 34475Project:

342408195EMSL Order:

This report has been prepared by EMSL Analytical, Inc. at the request of and for the exclusive use of the client named in this report. Completely read the important terms, conditions, and limitations that apply to this report.

© 2006,EMSL Analytical, Inc., All rights reserved. No part of this report may be reproduced or otherwise distributed or used without the express written consent of EMSL.

Test Report EXMold-2.1.0.0 Printed: 4/22/2024 08:41:41AM

EMSL Analytical, Inc.

3303 PARKWAY CENTER COURT Orlando, FL 32808 Phone: (407) 599-5887 Fax: (407) 599-9063 Web: http://www.EMSL.com Email:orlandolab@emsl.com

Attn: Debbie Koontz

DK Environmental

8786 Sonoma Coast Drive

Winter Garden, FL 34787

Proj: 1560 NW 14th Street Ocala, FL 34475

EMSL Order:

Customer ID:

Received:

Analyzed:

Collected:

342408195

DKEN75

4/19/2024 4/20/2024

4/19/2024

1. Description of Analysis

Analytical Laboratory

EMSL Analytical, Inc. (EMSL) is a nationwide, full service, analytical testing laboratory network providing Asbestos, Mold, Indoor Air Qual i ty, Microbiological , Environmental , Chemical , Forensic, Materials, Industrial Hygiene and Mechanical Testing services since 1981. Ranked as the premier independently owned environmental testing laboratory in the nation, EMSL puts analytical quality as its top priority. This quality is recognized by many well-respected federal, state and private accrediting agencies, and assured by our high quality personnel, including many Ph.D. microbiologists and mycologists.

EMSL is an independent laboratory that performed the analysis of these samples. EMSL did not conduct the sampling or site investigation for this report. The samples referenced herein were analyzed under strict quality control procedures using state-of-the-art microbiological methods. The analytical methods used and the data presented are scientifically and legally defensible.

The laboratory data is provided in compliance with ISO-IEC 17025 guidelines for the particular test(s) requested, including any associated limitations for the methods employed. These data are intended for use by professionals having knowledge of the testing methods necessary to interpret them accurately.

This report has been prepared by EMSL Analytical, Inc. at the request of and for the exclusive use of the client named in this report. Completely read the important terms, conditions, and limitations that apply to this report.

© 2006,EMSL Analytical, Inc., All rights reserved. No part of this report may be reproduced or otherwise distributed or used without the express written consent of EMSL.

Phone: (407) 599-5887 Fax: (407) 599-9063 Web: http://www.EMSL.com Email:orlandolab@emsl.com

Attn: Debbie Koontz

DK Environmental

8786 Sonoma Coast Drive

Winter Garden, FL 34787

Proj: 1560 NW 14th Street Ocala, FL 34475

EMSL Order:

Customer ID:

Received:

Analyzed:

Collected:

342408195

DKEN75

4/19/2024 4/20/2024

4/19/2024

Air Samples - Spore traps:

Spore traps are commercially available sampling devices that capture airborne particles on an adhesive slide. Air is pulled through the device using a vacuum pump. Spores, as well as other airborne particles, are impacted on the collection adhesive. Using spore trap collection methods has inherent limitations. These collection methods are biased towards larger spore sizes.

The analysis for total spore counts is a direct microscopic examination and does not include culturing or growing the fungi. Therefore, the results include both viable and non-viable spores .

Some fungal groups produce s imi lar spore types that cannot be d is t ingu ished by d i rect microscopic examination alone (i.e., Aspergillus/Penicillium, and others). Other spore types may lack distinguishing features that aid in their identification. These types are grouped into larger categories such as Ascospores or Basidiospores.

Fungal spores are identified and grouped by morphological characteristics including color, shape, septation, ornamentation, and fruiting structures (if present) which are compared to published mycological identification keys and texts. EMSL reports provide spore counts per cubic meter of air to three significant figures. Please note that each spore category is reported to three significant figures. Due to rounding and the application of three significant figures the sum of the individual spore numbers may not equal the total spore count on the report. EMSL does not maintain responsibility for final volume concentrations (counts/m3) since this volume is provided by the field collector and can not be verified by EMSL.

EMSL analyzes spore traps using phase contrast microscopy. There is a wide choice of collection devices (Air-O-Cell, Micro-5, Burkhard, etc.) on the market. Differences in analytical method may exist between spore trap devices.

Spore trap results are reported in spores per cubic meter of air. Due to the other airborne particles collected with the spores, EMSL reports a background particle density. Background density is an indicat ion of overal l par t icu late mat ter present on the sample ( i .e . dust in the a i r ) . High background concentrations may obscure spores such as the Penicillium/Aspergillus group. The rating system is from 1-5 with 1 = 1 - 25% of the background obscured by material, 2 = 26 - 50% , 3 = 51 - 75%, 4 = 76% - 99%, 5 = 100% or overloaded. A background rating of 4 or higher should be regarded as a minimum count since the actual concentrations may be higher than those reported. EMSL will not be held responsible for overloading of samples. Sample volumes are left to the discretion of the company or persons conducting the fieldwork.

Skin fragment density is the percentage of skin cells making up the total background material, 1 =

1 - 25%, 2 = 26 - 50%, 3 = 51 - 75%, 4 = 76-100%. Skin fragment density is considered an indication of the general cleanliness in the area sampled. It has been estimated that up to 90% of household dust consists of dead skin cells.

This report has been prepared by EMSL Analytical, Inc. at the request of and for the exclusive use of the client named in this report. Completely read the important terms, conditions, and limitations that apply to this report.

© 2006,EMSL Analytical, Inc., All rights reserved. No part of this report may be reproduced or otherwise distributed or used without the express written consent of EMSL.

Phone: (407) 599-5887 Fax: (407) 599-9063 Web: http://www.EMSL.com Email:orlandolab@emsl.com

Attn: Debbie Koontz

DK Environmental

8786 Sonoma Coast Drive

Winter Garden, FL 34787

Proj: 1560 NW 14th Street Ocala, FL 34475

EMSL Order:

Customer ID:

Received:

Analyzed:

Collected:

342408195

DKEN75

4/19/2024 4/20/2024

4/19/2024

2. Analytical Results

See attached data reports and charts.

This report has been prepared by EMSL Analytical, Inc. at the request of and for the exclusive use of the client named in this report. Completely read the important terms, conditions, and limitations that apply to this report.

© 2006,EMSL Analytical, Inc., All rights reserved. No part of this report may be reproduced or otherwise distributed or used without the express written consent of EMSL.

Phone: (407) 599-5887 Fax: (407) 599-9063 Web: http://www.EMSL.com Email:orlandolab@emsl.com

Attn: Debbie Koontz

DK Environmental

8786 Sonoma Coast Drive

Winter Garden, FL 34787

Proj: 1560 NW 14th Street Ocala, FL 34475

EMSL Order:

Customer ID:

Received:

Analyzed:

Collected:

342408195

DKEN75

4/19/2024 4/20/2024

4/19/2024

Test Report: Allergenco-D(™) Analysis of Fungal Spores & Particulates by Optical Microscopy (Methods MICRO-SOP-201, ASTM D7391)

Lab Sample Number:

Client Sample ID:

Volume (L):

Sample Location:

342408195-0001

5576221

342408195-0002

5576210

342408195-0003

5576262

Exterior N Wall B/C Interior Kitchen Interior SW Bedroom

Spore Types Raw Count Count/m³ % of Total Raw Count Count/m³ % of Total Raw Count Count/m³ % of Total

Alternaria (Ulocladium) 1 40 0.4 - - - - - -

Ascospores 18 790 7.5 2 90 2.5 1 40 3

Aspergillus/Penicillium++ 20 870 8.3 66 2900 81.2 20 870 64.4

Basidiospores 183 7990 76.2 4 200 5.6 6 300 22.2

Bipolaris++ - - - - - - - - -

Chaetomium++ - - - - - - - - -

Cladosporium 12 520 5 6 300 8.4 3 100 7.4

Curvularia - - - - - - - - -

Epicoccum - - - - - - - - -

Fusarium++ - - - - - - - - -

Ganoderma 2 90 0.9 - - - - - -

Myxomycetes++ 3 100 1 1 40 1.1 - - -

Pithomyces++ - - - - - - - - -

Rust 2 90 0.9 1 40 1.1 1 40 3

Scopulariopsis/Microascus - - - - - - - - -

Stachybotrys/Memnoniella - - - - - - - - -

Unidentifiable Spores - - - - - - - - -

Zygomycetes - - - - - - - - -

Total Fungi 241 10490 100 80 3570 100 31 1350 100

Hyphal Fragment 2 90 - 1 40 - - - -

Insect Fragment 2 90 - - - - 1* 10* -

Pollen 5 200 - 2 90 - 1 40 -

Analyt. Sensitivity 600x - 44 - - 44 - - 44 -

Analyt. Sensitivity 300x - 13* - - 13* - - 13* -

Skin Fragments (1-4) - 1 - - 2 - - 2 -

Fibrous Particulate (1-4) - 1 - - 2 - - 2 -

Background (1-5) - 2 - - 2 - - 2 -

No discernable field blank was submitted with this group of samples.

Yessica Martinez Seeman, Florida Microbiology

Regional Manager

Initial report from: 04/22/2024 08:41:41

EMSL Analytical, Inc. maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by

EMSL Analytical, Inc. EMSL Analytical, Inc. bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Skin Fragment and Fibrous Particulate ratings are based on the percent of non-fungal material they represent: 1 (1-25%), 2 (26-50%), 3 (51-75%), or 4 (76-100%). Background ratings are based on the total area covered by non-fungal particles: 1 (1-25%), 2 (26-50%), 3 (51-75%), 4 (76-99%), or 5 (100%; overloaded). High levels of background particulate can obscure spores and other particulates, leading to underestimation. Background levels of 5 indicate an overloading of background particulates, prohibiting accurate detection and quantification. Present = Spores detected on overloaded samples. Results are not blank corrected unless otherwise noted. The detection limit is equal to one fungal spore, structure, pollen, fiber particle or insect fragment. "*" Denotes particles found at 300X. "-" Denotes not detected. Due to method stopping rules, raw counts >= 100 are extrapolated based on the percentage analyzed.

++ Includes other spores with similar morphology; see EMSL's fungal glossary for each specific category.

This report has been prepared by EMSL Analytical, Inc. at the request of and for the exclusive use of the client named in this report. Completely read the important terms, conditions, and limitations that apply to this report.

© 2006,EMSL Analytical, Inc., All rights reserved. No part of this report may be reproduced or otherwise distributed or used without the express written consent of EMSL.

Test Report EXMold-2.1.0.0 Printed: 4/22/2024 08:41:41AM

Chris Highlight

Chris Highlight

Chris Highlight

Phone: (407) 599-5887 Fax: (407) 599-9063 Web: http://www.EMSL.com Email:orlandolab@emsl.com

Attn: Debbie Koontz

DK Environmental

8786 Sonoma Coast Drive

Winter Garden, FL 34787

Proj: 1560 NW 14th Street Ocala, FL 34475

EMSL Order:

Customer ID:

Received:

Analyzed:

Collected:

342408195

DKEN75

4/19/2024 4/20/2024

4/19/2024

Test Report: Microscopic Examination of Fungal Spores, Fungal Structures, Hyphae, and Other Particulates from Tape Samples (EMSL Method MICRO-SOP-200)

Lab Sample Number:

Client Sample ID:

Sample Location:

342408195-0004

1560-1

342408195-0005

1560-2

342408195-0006

1560-3

342408195-9901

Dummy

342408195-9902

Dummy

Interior Kitchen S Lower

Wood Wall Cavity

Interior SW Bedroom NW

Wood Baseboard

Interior E Bathroom Wood

Baseboard Dummy Dummy

Spore Types Category Category Category - -

Alternaria (Ulocladium) - - - - -

Ascospores - - - - -

Aspergillus/Penicillium++ - Low Low - -

Basidiospores - - - - -

Bipolaris++ Rare - - - -

Chaetomium++ - Rare - - -

Cladosporium - *High* - - -

Curvularia - - - - -

Epicoccum - - - - -

Fusarium++ - - - - -

Ganoderma - - - - -

Myxomycetes++ Rare - - - -

Pithomyces++ - - - - -

Rust - - - - -

Scopulariopsis/Microascus - Medium Rare - -

Stachybotrys/Memnoniella - - - - -

Unidentifiable Spores - - - - -

Zygomycetes - - - - -

Aspergillus *High* - - - -

Scolecobasidium++ - Low - - -

Hyphal Fragment - - - - -

Insect Fragment Low Medium Rare - -

Pollen - Low Rare - -

Fibrous Particulate - - - - -

Category: Count/per area analyzed

Rare: 1 to 10 Low: 11 to 100 Medium: 101 to 1000 High: >1000

High background particulate: A high level of background particulate can obscure fungal matter and lead to underestimation or failure to detect

++ = Includes other spores with similar morphology; see EMSL's fungal glossary for each specific category.

* = Sample contains fruiting structures and/or hyphae associated with the spores.

- = Not detected.

Yessica Martinez Seeman, Florida

Microbiology Regional Manager

No discernable field blank was submitted with this group of samples.

Samples analyzed by EMSL Analytical, Inc. Orlando, FL AIHA LAP, LLC-EMLAP Accredited #163563

EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.

Initial report from: 04/22/2024 08:41:41

This report has been prepared by EMSL Analytical, Inc. at the request of and for the exclusive use of the client named in this report. Completely read the important terms, conditions, and limitations that apply to this report.

© 2006,EMSL Analytical, Inc., All rights reserved. No part of this report may be reproduced or otherwise distributed or used without the express written consent of EMSL.

Test Report EXMold-2.1.0.0 Printed: 4/22/2024 08:41:41AM

Chris Highlight

Chris Highlight

Chris Highlight

Chris Highlight

Chris Highlight

Chris Highlight

Chris Highlight

Chris Highlight

Chris Highlight

Chris Highlight

Chris Highlight

Phone: (407) 599-5887 Fax: (407) 599-9063 Web: http://www.EMSL.com Email:orlandolab@emsl.com

Attn: Debbie Koontz

DK Environmental

8786 Sonoma Coast Drive

Winter Garden, FL 34787

Proj: 1560 NW 14th Street Ocala, FL 34475

EMSL Order:

Customer ID:

Received:

Analyzed:

Collected:

342408195

DKEN75

4/19/2024 4/20/2024

4/19/2024

EMSL Analytical, Inc. is an independent laboratory, providing unbiased and scientifically valid results. These data represent only a portion of an overall IAQ investigation. Visual information and environmental conditions measured during the site assessment (humidity, moisture readings, etc.) are crucial to any final interpretation of the results. Many factors impact the f inal results; therefore, result interpretat ion should only be conducted by qualif ied individuals. The American Conference of Governmental Industrial Hygienists

(ACGIH) has published a good reference book covering sampling and data interpretation. It is entitled, Bioaerosols: Assessment and Control, 1999.

Fungal spores are found everywhere. Whether or not symptoms develop in people exposed to fungi depends on the nature of the fungal material (e.g., allergenic, toxic, or infectious), the exposure level, and the susceptibility of exposed persons.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .