Exhibit_D-Florissant_Bid_Dwg_Set.pdf
PDF 8 MB Posted
- Attached to
- Florissant Golf Club Irrigation
- Solicitation number
- 25-0259-PR
- Issued by
- St. Louis County, Missouri
About this file
This document is a bid drawing set (Exhibit D) for the Florissant Golf Club irrigation system installation project in Florissant, Missouri. The project requires the installation of a complete new Rain Bird Integrated Control (IC) irrigation system throughout the golf course property, including HDPE mainline and lateral piping systems, Rain Bird IC sprinkler heads for greens, tees, fairways, and perimeter areas, and associated electrical and communication components. The irrigation system design consists of two control paths: Path 1 contains 310 stations and Path 2 contains 272 stations. The sprinkler head specifications include 227 Rain Bird A-952-IC-80-52 units (80 psi, 83' range, 36.3 gpm), 9 additional A-952-IC-80-52 units, 134 A-702-IC-80-36 units (80 psi, 70' range, 28.3 gpm), 178 A-752-IC-80-36 units (80 psi, 68' range, 24.7 gpm), 30 A-752-IC-80-26 units (80 psi, 51' range, 11.6 gpm), and 578 VIH units for a total of 1,156 irrigation heads. The pump station discharge specifications are 800 gpm at 103 psi with potable static pressure of 85 psi. Piping materials include HDPE 4710 DR13.5 in various sizes (2" through 18") and 1" PVC CL 200 lateral piping, with minimum bend radius requirements specified for all installations.
The contractor is solely responsible for developing accurate material takeoff quantities including normal installation waste and must notify the architect and owner of any significant discrepancies between their takeoff and the CAD-provided counts prior to bid submission. The Integrated Control (IC) electrical system requires 14 AWG communication cable routed along two distinct primary trunk and branch paths, with Integrated Control Surge Devices (ICSD) installed no farther than 500 feet apart or with no more than 15 ICM (Integrated Control Modules) between each ICSD. All ground resistance must be established at 50 ohms or less at each ICSD, with measurements recorded in field notes. The contractor must provide complete compliance with current Rain Bird IC system installation recommendations, include all voltage regulation and surge devices recommended by the manufacturer, coordinate with existing buried utilities on the golf course, and prepare comprehensive as-built documentation including digital long addresses for each ICM, pipe routing, wiring paths, valves, splices, and control component locations. Construction must be sequenced to maintain golf course operations with all but one hole open at any time, with each hole completed before proceeding to the next.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Path 1 = 310 Stations
Path 2 = 272 Stations
G1 G2
G3
G4
P1
P2
P3
P4
F1
F2 F3R1R2
T1
T2
T3
T4
G1
G2
G3
G4
P1
P2 P3
P4
F1
F2F3
F4F5
F6F7 F8
F9 F10
F11
F12
F13
F14
F15 F16
R1 R2
R3
R4
R5
T1
T2
T3
T4
T5
T6
T7
T8
G1
G2
G3
G4 P1
P2 P3
P4
F1F2
F3F4
F5
F6
F7
F8
F9
F10
F11
F12
F13
T1T2
T3T4
T5
G1
G2
G3
G4 P1
P2
P3
P4R1
R2
F1 F2
F3
F4
F5
F6 F7
F8 F9
F10 F11
F12 F13
F14 F15
F16 F17
F18
T1
T2
T3
T4
T5 G1
G2 G3
G4 P1
P2
P3
P4 F1
F2
R1
R2
R3
T1
T2
T3
T4
T5
T6 G1
G2
G3
G4
P1
P2 P3
P4 F1
F2 F3
F4 F5
F6 F7
F8 F9
F10 F11
F12 F13
F14 F15
F16 F17
F18 F19
F20 F21
F22 F23
F24 F25
F26 F27
F28 F29
F30 F31
F32 F33
F34
R1
R2
R3
R4
R5
R6
R7
R8
T1
T2
T3
G1
G2
G3
G4 P1
P2 P3
P4
F1 F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
F13
F14
T1
T2
T3
T4
T5
G1
G2 G3
G4 P1
P2
P3
R1
F1 F2
F3
F4
F5
F6
R2
R3
R4
T1 T2
T3
T4
T5
T6
T7
G1
G2 G3
G4
G5
P1 P2
P3
G1
G2
G3
G4
P1
P2 P3
P4
R1
R2
F1
F2 F3 F4
F5
F6
F7
F8
F9
F10
F11
T1 T2
T3
T4
T5
T6
T7
T8
G1
G2
G3
G4
P1
P2
P3
P4
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
F13
F14
F15
F16
F17
F18
F19
F20
F21
F22
F23 F24
F25
T1T2T3 T4T5T6
G1G2
G3 G4
P1
P2
P3 P4
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
F13
F14
F15
F16
F17
F18
F19
F20
F21
F22
F23
F24
F25
F26
F27
F28
F29
F30 F31 F32
T1
T2
T3 T4 T5
T6 G1
G2
G3
G4
P1
P2 P3
P4
T1
T2
T3
T4
T5
T6 G1
G2
G3G4
P1 P2
P3 P4
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
F13
F14
F15
F16
F17
F18
F19
F20
F21
F22
F23
F24
F25
F26
R1R2 R3T1T2T3T4
G1 G2
G3
G4
P1 P2
P3
P4
F1F2 F3
R1R2
R3 R4
T1
T2
T3
T4
T5 T6
T7
G1
G2
G3
G4 P1
P2P3
P4
F1 F2F3
F4F5
F6F7
F8F9
F10F11
F12
F13
F14
F15
F16
F17
F18
F19
F20
F21
R1
R2
T1
T2T3
T4T5
T6T7
T8
T9
T10
G1
G2
G3 G4
P1P2
P3 P4
F1
F2
F3
F4 F5 F6 F7 F8 F9
T1 T2
T3
T4
T5
T6
G1 G2
G3
G4
P1
P2
P3
P4
R1
F1 F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
F13
T1
T2
T3
T4
T5
T6 T7
T8
G1
G2 G3
G4 P1
P2
P3
P4
F1 F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
F13
F14
F15
F16
R1
R2
R3
T1
T2
T3
T4
T5T6
T7
T8
T9
The Contractor is solely responsible for developing his own material takeoff quantities, including normal installation waste and all other factors that contribute to material requirements and losses.
Quantities shown are software reported with no installation allowances. The Contractor shall notify the Architect and Owner of any perceived significant discrepancies between his takeoff and the CAD Counts prior to submitting his bid proposal.
Pump Station Discharge:
(800 gpm @ 103 psi) (Potable Static 85 psi)
Maintenance Shop
0 100 200
Scale in Feet
AR
AR
AR
AR
PG
Sprinkler Head Legend & Count Units Description
227 Rain Bird A-952-IC-80-52; 80 psi, 83', 36.3 gpm
9 Rain Bird A-952-IC-80-52; 80 psi, 83', 36.3 gpm
134 Rain Bird A-702-IC-80-36; 80 psi', 70', 28.3 gpm
178 Rain Bird A-752-IC-80-36; 80 psi', 68', 24.7 gpm
5 Rain Bird A-752-IC-80-26; 80 psi, 51', 11.6 gpm
25 Rain Bird A-752-IC-80-26; 80 psi, 51', 11.6 gpm
578 VIH Total
0 Rain Bird A-752 B-80-24; 80 psi, 48', 10.2 gpm
0 Rain Bird 5006+PCSAMRSS; 45 psi; 37', 2.51 gpm
0 Block/Commercial Sub-Total
578 Total
Irrigation Legend Quick Coupler Valve as specified
Remote Control Valve as specified
Main Isolation Gate Valve; AWWA; Line Size
Sub-Main Isolation Valve as specified
Pipe; HDPE 4710 DR as specified; Size Noted by color
PVC Lateral Piping (block valve lateral piping)
Air Release Valve; Bermad 1"
Control System Station Tag Assignment
Control System Hole Boundary F12
AR
12"
2"
3"
4"
6"
8"
10"
5'
7.3'
9.4'
26.6'
13.8'
18.0'
22.4'
HDPE Minimum Radius Pipe curvature shall not be allowed within 24" of any fitting, saddle, or service tee.
1" PVC CL 200
2" HDPE 4710 DR13.5
3" HDPE 4710 DR13.5
4" HDPE 4710 DR13.5
6" HDPE 4710 DR13.5
8" HDPE 4710 DR13.5
10" HPDE 4710 DR13.5
12" HDPE 4710 DR13.5
18" HDPE 4710 DR13.5
Pipe Legend & Size
Irrigation System 04/13/26 08:13
04/13/26 08:13 1 of 2 Head and Pipe Layout 1Florissant.dwg
Time:
Drawing:
Golfmapstm
Sheet:
IPD, LLC
Irrigation Planning & Design P.O. Box 2717 Georgetown, Texas 78627 Tel: 512-924-3942LLC
Florissant Golf Club Florissant, Missouri
Path 1 = 310 Stations
Path 2 = 272 Stations
The Contractor is solely responsible for developing his own material takeoff quantities, including normal installation waste and all other factors that contribute to material requirements and losses.
Quantities shown are software reported with no installation allowances. The Contractor shall notify the Architect and Owner of any perceived significant discrepancies between his takeoff and the CAD Counts prior to submitting his bid proposal.
Pump Station Discharge:
(800 gpm @ 103 psi) (Potable Static 85 psi)
Maintenance Shop
0 100 200
Scale in Feet
111 IC Primary Trunk/Branch Path 1; 14 AWG IC Primary Trunk/Branch Path 2; 14 AWG
The Primary Trunk and Branch routing shown does not include the secondary/lateral runs along the lateral pipe routing to the VIH sprinklers or to the remote control valves. The Contractor shall be solely responsible for determining the the proper and necessary lengths of all wire paths.
The Integrated Control Surge Device (ICSD) shall be installed with grounding rods along the primary "Trunk" IC wire path as noted on the drawing. In no case shall ICSD be farther than 500 feet from the adjacent ICSD or for no more than 15 ICM between each ICSD. Grounding shall establish a ground resistance of 50 ohms or less.
Rain Bird communication cable shall be 12/2 or 14/2 MAXI Cable meeting all manufacturing specifications for use with the Rain Bird IC system.
Rain Bird IC Electrical Legend
1. These IC Installation Notes are supplemental and are in addition to the complete specifications and requirements provided in the Bid Document.
2. The Contractor shall exercise special care to assure the proper installation of all wiring for the Integrated Control IC Modules and IC Surge Devices. The IC system shall be installed in complete compliance with the most current recommendations and instructions available from Rain Bird at the time of installation.
3. The Integrated Control Surge Device (ICSD) shall be installed with grounding rods along the primary "Trunk" IC wire path as noted on the drawing. In no case shall ICSD be farther than 500 feet from the adjacent ICSD or for no more than 15 ICM between each ICSD or as instructed by the Manufacturer.
4. The Contractor shall establish ground resistance at each ICSD of 50 ohms or less. The resistance shall be measured at each ICSD and recorded on the as built field notes. The Contractor shall be responsible for all materials and labor necessary to establish satisfactory ground resistance in accordance with all Rain Bird installation recommendations.
5. Each splice shall be constructed with sufficient slack to allow the splice to be raised 18" above the finish grade.
All splices, other than for VIH sprinklers, shall be installed inside a 10" round valve box with a black valve box cover and clearly noted on the construction and as built notes and drawing.
6. Wires to each VIH Integrated Control Module (ICM) shall be neatly folded and buried next to the VIH sprinklers.
7. The contractor shall identify and record the digital long address for each ICM at the time of making the field splice to each ICM. Each address shall be identified as noted on the as-staked installation drawings and provided to the Design Consultant on approved forms with other as built field notes.
8. The IC Trunk, major branch, and all minor branch routings to each ICM shall be clearly indicated on the construction field notes and submitted with the ICM digital address.
9. Each of the 2 primary IC wire paths shall be a distinct and different in color than other primary paths. In addition to the 2 primary trunk and branch path colors, a 3rd color shall be used for all secondary/lateral IC wire paths beginning at the 3-way splice for the lateral routing. This clearly indicates at all 3-way lateral splices location which wires are the primary path and which is the lateral wire run.
10. All 3-way lateral IC wire splices shall be made at the nearest sprinkler to the main line and primary branch routing.
11. The Contractor shall include in their bid all voltage regulation and surge devices recommended by Rain Bird.
12. There are buried utilities on the golf course which may not be indicated on the Contract Drawings. The Contractor shall be responsible to identify and to avoid such utilities. Special care, notification, and cooperation shall be provided in the coordination of all work related to the crossing of buried utilities.
Integrated Control (IC) Installation Notes:
AR
AR
AR
AR
PG
Irrigation System 04/13/26 08:13
04/13/26 08:13 2 of 2
1Florissant.dwg Time:
Drawing:
Golfmapstm
Sheet:
IPD, LLC
Irrigation Planning & Design P.O. Box 2717 Georgetown, Texas 78627 Tel: 512-924-3942LLC
Florissant Golf Club Florissant, Missouri Electrical 2-Wire Routing