This is a Master Specifications document from the Executive Office for United States Attorneys (EOUSA) that provides detailed technical requirements and standards for construction and renovation of U.S. Attorney office spaces. The 59-page document includes comprehensive specifications for doors, walls, windows, finishes, millwork, HVAC, electrical systems, trial prep spaces, Secure Processing Rooms (SPR), and elevator control systems. Key requirements include specific door types with ballistic ratings, security features like electric strikes and magnetic contacts, STC-rated walls (45-50) for sound attenuation, specialized HVAC controls for computer rooms, and detailed electrical/security infrastructure requirements.
The document details exacting standards for materials and installation, including specific product models and manufacturers for items like locks (Medeco), door hardware (Von Duprin), and ballistic materials (North American Bulletproof). Notable requirements include ballistic-rated doors and windows in waiting areas, RF-protected secure processing rooms, dedicated HVAC systems for computer rooms, and detailed specifications for finish materials like carpet (CRI-rated) and millwork. The specifications emphasize security features throughout, with requirements for access control systems, door contacts, dedicated electrical circuits, and grounding of all metallic components. This appears to be the current version, updated March 10, 2022.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Master Specifications
Executive Office for United States Attorneys Updated: March 10, 2022
Page 1 of 59 LESSOR:______GOVERNMENT:______
EXHIBIT C1
DEPARTMENT OF JUSTICE
175 N. Street NE, Suite 6.200 Washington, DC 20530. 202.252.5940
Facilities, Acquisition and Support Services
Updated: March 10, 2022
Page 2 of 59 LESSOR:______GOVERNMENT:______
INDEX
Door Types 3 Wall Types 29 Windows 36 Finishes 37 Millwork 42
HVAC 43
Electrical 45 Trial Prep 50
SPR 51
Elevator Control 55
This document is intended to serve as a guide for developing design and construction documents for all United States Attorney’s Offices. It is the responsibility of the local Project Architect, Engineer and/or General Contractor to apply the specifications stated herein and to comply with all local codes and construction methods. Interpretation of these specifications is at the sole discretion of EOUSA. Not all information specified herein will necessarily apply to all projects. Substitutions for listed hardware, etc. are not acceptable. DOJ Master Specifications take precedence over and govern all USAO project construction documents.
If any information contained within this document is deemed outdated or inaccurate, please contact Facilities, Management and Support Services (FMSS) at:
3CON
175 N Street NE, 6th Floor Washington, DC 20002 Tel. 202.252.5940 Fax. 202.252.5969
General Note:
All corridors within US Attorney controlled space shall be a minimum of 5’-0” wide.
Useful Websites
US Attorney Website http://www.usdoj.gov/usao/
USAO Design Guide Ask for revised PDF http://www.usdoj.gov/usao/eousa/foia_reading_room/usam/title3/usa00158.htm
Von Duprin Hardware http://www.vonduprin.com/
Simplex Hardware http://www.kaba-ilco.com/
Ballistic Window & Drs http://shotgard.com/ http://www.armortex.com/products.html
Antennas http://www.tripointglobal.com/antennas/data sheets/76-1-12ro.pdf
X-Ray Security Screening System http://www.rapiscansystems.com/en/products/bpi/productsrapiscan_618xr
Walkthrough Metal Detection System http://www.rapiscansystems.com/en/products/ps/productsmetor_6m
Air Purification System http://www.dynamicaqs.com/commercial/
Hirsch Back Boxes http://www.hirsch-identive.com/
In-Duct View Port http://www.mcgillairflow.com/textDocs/accessDoors/ad_hinged.htm
Metal Mesh http://amico-grating.com/regular-expanded-metal.htm http://www.usdoj.gov/usao/ http://www.usdoj.gov/usao/eousa/foia_reading_room/usam/title3/usa00158.htm http://www.vonduprin.com/ http://www.kaba-ilco.com/ http://shotgard.com/ http://shotgard.com/ http://www.armortex.com/products.html http://www.tripointglobal.com/antennas/data%20sheets/76-1-12ro.pdf http://www.rapiscansystems.com/en/products/bpi/productsrapiscan_618xr http://www.rapiscansystems.com/en/products/ps/productsmetor_6m http://www.dynamicaqs.com/commercial/ http://www.hirsch-identive.com/ http://www.mcgillairflow.com/textDocs/accessDoors/ad_hinged.htm http://amico-grating.com/regular-expanded-metal.htm
Updated: March 10, 2022
Page 3 of 59 LESSOR:______GOVERNMENT:______
DOOR TYPES
D-01 Ballistic Perimeter Door (Out-Swinging) @ Waiting Area:
▪ Single ballistic door, UL 752, Level 3 rated, solid core wood w/metal frame manufactured by North American Bulletproof, San Antonio, TX (http://shotgard.com/) 210.225.0982.
door and frame are to be prepped at the factory for the hardware listed below.
▪ Mechanical door closer, LCN 4040 series, installed secure side.
▪ Door Release Device: A security grade emergency door release device with a key over ride. Outside trim is lever action, electric locking. Von Duprin 99-996-(Finish)-(size)-Storeroom/Nightlatch function. Medeco M3 keyway, removable cylinder, key should be factory restricted level 7.
▪ HES 9600 Electric Strike.
▪ Door and Frame to be mortised at the factory to accept magnetic door contacts, GE 2767 high security recessed on non-hinge side of door.
▪ Door contacts to be F&I by Security Contractor with General Contractor F&I ¾” EMT conduit stub up with insulated bushings and pull string to General Contractor F&I 12”x12”x4” J-box above ceiling on secure side.
▪ A single 4”x4” (1900 deep) electrical box with ¾” knock outs. The box shall be equipped with the appropriate sized single gang plaster ring. The size of the plaster ring shall be determined by the finished wall thickness.
▪ The single gang plaster ring shall be flush mounted to the finished wall surface. with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side
▪ Continuous hinge.
▪ (1) Floor mounted stop and (3) door silencers.
See drawing next page.
Updated: March 10, 2022
Page 4 of 59 LESSOR:______GOVERNMENT:______
Page 5 of 59 LESSOR:______GOVERNMENT:______
D-01a
Ballistic Perimeter Door (In-Swinging) @ Waiting Area:
▪ Single ballistic door, UL 752, Level 3 rated (Model# WDR3684-P), solid core wood w/metal frame manufactured by North American Bulletproof, San Antonio, TX (http://shotgard.com/)
210.225.0982. Door and frame are to be prepped at the factory for the hardware listed below.
▪ Mechanical door closer, LCN 4040 series, installed secure side.
▪ Medeco M3 keyway, removable cylinder, key should be factory restricted level 7.
▪ HES 8500 Electric Strike.
▪ Continuous hinge, PEMKO 100 Series
▪ Door and Frame to be mortised at the factory to accept magnetic door contacts, GE 2767 high security recessed on non-hinge side of door, furnished and installed by Security Contractor with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side
▪ (1) Floor mounted stop and (3) door silencers.
▪ A single 4”x4” (1900 deep) electrical box with ¾ “ knock outs. The box shall be equipped with the appropriate sized single gang plaster ring. The size of the plaster ring shall be determined by the finished wall thickness.
▪ The single gang plaster ring shall be flush mounted to the finished wall surface. with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side
D-01B Ballistic Firearms Room Door (In-Swinging) @ Waiting Area:
▪ Single ballistic door, UL Standard 752, Level 3 rated (Model# WDR3684-P), solid core wood w/metal frame manufactured by North American Bulletproof, San Antonio, TX
(http://shotgard.com/) 210.225.0982. Door and frame are to be prepped at the factory for the hardware listed below.
▪ Mechanical door closer, LCN 4040 series, installed secure side.
▪ Medeco M3 keyway, removable cylinder, key should be factory restricted level 7.
▪ HES 8500 Electric Strike.
▪ Continuous hinge, PEMKO 100 Series
▪ Grouted frame…
▪ Door and Frame to be mortised at the factory to accept magnetic door contacts, GE 2767 high security recessed on non-hinge side of door, furnished and installed by Security Contractor with
¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side
▪ (1) Floor mounted stop and (3) door silencers.
▪ A single 4”x4” (1900 deep) electrical box with ¾ “ knock outs. The box shall be equipped with the appropriate sized single gang plaster ring. The size of the plaster ring shall be determined by the finished wall thickness.
▪ The single gang plaster ring shall be flush mounted to the finished wall surface. with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side
Updated: March 10, 2022
Page 6 of 59 LESSOR:______GOVERNMENT:______
D-02 Entry Door from Elevator Lobby to Waiting Area:
▪ Single or double door configuration (min. 3’-0” x 6’-8”) w/metal frame or storefront with optional sidelights. Door and frame are to be prepped at the factory for the hardware listed below.
▪ Medeco Bilevel standard cylinder lockset w/Medeco Maxum deadbolt Model # D-11, w/ push paddle on secure side for egress, classroom function lockset optional.
▪ Mechanical door closer, LCN 4040 series, with manual hold open function for daytime hours.
Installed secure side.
▪ Non-removable pin security hinges.
▪ (1) Floor mounted stop and (3) door silencers.
Note: If double door configuration is used – Install Sargent & Greenleaf SM1881 sliding door bolts on inactive leaf.
D-02a (Out-Swinging) Entry Door Waiting Area
▪ Single door (min. 3’-0” x 6’-8”) w/metal frame. Door and frame are to be prepped at the factory for the hardware listed below.
▪ A store room function ANSI grade 2 (minimum) leverset, with Medeco bilevel lock cylinder
▪ Electric strike, HES 1006CS high security electric strike Fail Secure with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side
▪ Non-removable pin security hinges for out swinging doors.
▪ Latch protector, Don-Jo Mfg. PLP-211 (BP- Brass Plated/SC-Silver Coated) for out-swinging doors.
▪ A single 4”x4” (1900 deep) electrical box with ¾ “ knock outs. The box shall be equipped with the appropriate sized single gang plaster ring. The size of the plaster ring shall be determined by the finished wall thickness.
▪ The single gang plaster ring shall be flush mounted to the finished wall surface. with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side
▪ Floor mounted stop and (3) door silencers.
Updated: March 10, 2022
Page 7 of 59 LESSOR:______GOVERNMENT:______
D-03 Door to Secure Witness Suite - Room from Waiting Area (Threat Side):
▪ 1-3/4” x 3’-0” x 6’-8” min. acoustical single solid wood door w/ metal frame (STC 45). Door and frame are to be prepped at the factory for the hardware listed below.
▪ Medeco bilevel cylinder ANSI grade 2 lockset Store Room Function.
▪ Electric strike, HES 1006CS high security electric strike Fail Secure, with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side.
▪ Non-removable pin security hinges for out swinging doors.
▪ Latch protector, Don-Jo Mfg. PLP-211(BP-Brass Plated/SC-Silver Coated) for out-swinging doors.
▪ Mechanical door closer, LCN 4040 series, installed secure side.
▪ Mechanical door sweep and screw-on continuous sound gasket to achieve an STC 45.
▪ (1) Floor mounted stop.
D-03a Door to Secure Witness Suite - Room from Interior Corridor (Secure Side):
▪ 1-3/4” x 3’-0” x 6’-8” min. acoustical single solid wood door w/ metal frame (STC 45). Door and frame are to be prepped at the factory for the hardware listed below.
▪ Building standard lockset.
D-04 Secondary Suite Perimeter Egress Door - (Outward Swing):
▪ 1-3/4” x 3’-0” x 6’-8” min. acoustical single solid wood or metal clad door (STC 45) with no windows or vents, and a continuously welded metal frame filled with sound deadening material (STC 45). Door and frame are to be prepped at the factory for the hardware listed below.
▪ Mechanical door closer, LCN 4040 series, installed secure side.
▪ Door Release Device: A security grade emergency door release device with a key over ride. Outside trim is lever action. Von Duprin 99-996-(Finish)-(size)-Storeroom/Nightlatch function. Medeco M3 keyway, removable cylinder, key should be factory restricted level 7.
▪ HES 9600 Electric Strike.
▪ Stainless Steel Cam Lift hinges.
▪ Door contacts to be F&I by Security Contractor with General Contractor F&I ¾” EMT conduit stub up with insulated bushings and pull string to General Contractor F&I 12”x12”x4” J-box above ceiling on secure side.
▪ In-door viewing device (DoorScope DS238 Metallic Ultra Wide Angle).
▪ A single 4”x4” (1900 deep) electrical box with ¾” knock outs. The box shall be equipped with the appropriate sized single gang plaster ring. The size of the plaster ring shall be determined by the finished wall thickness.
▪ The single gang plaster ring shall be flush mounted to the finished wall surface. with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side
See drawing below.
Page 8 of 59 LESSOR:______GOVERNMENT:______
Updated: March 10, 2022
Page 9 of 59 LESSOR:______GOVERNMENT:______
D-04b
Secondary Suite Perimeter Door / ADP Room Door - (Inward Swing):
▪ 1-3/4” x 3’-0” x 6’-8” min. acoustical single solid wood or metal clad door (STC 45) with no windows or vents, and a continuously welded metal frame with sound deadening material (STC 45). Door and frame are to be prepped at the factory for the hardware listed below.
▪ Mechanical door closer, LCN 4040 series, installed secure side.
▪ Stainless Steel Cam Lift hinges.
▪ Door contacts to be F&I by Security Contractor with General Contractor F&I ¾” EMT conduit stub up with insulated bushings and pull string to General Contractor F&I 12”x12”x4” J-box above ceiling on secure side.
▪ In-door viewing device (DoorScope DS238 Metallic Ultra Wide Angle)
▪ A single 4”x4” (1900 deep) electrical box with ¾” knock outs. The box shall be equipped with the appropriate sized single gang plaster ring. The size of the plaster ring shall be determined by the finished wall thickness.
▪ The single gang plaster ring shall be flush mounted to the finished wall surface with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side.
▪ Corbin Russwin ML2000 Series Storeroom Function Mortise Lockset (latchbolt by key outside, or grip inside).
▪ HES 8500 Series Electric Strike for mortise locks.
▪ Medeco M3 keyway, removable cylinder, key should be factory restricted level 7.
▪ Mechanical door sweep and screw-on continuous sound gasket to achieve an STC 45.
▪ Floor mounted stop.
▪ (Latch protector, Don-Jo Mfg. PLP-211 (BP-Brass Plated/SC-Silver Coated) for out-swinging ADP room doors.)
Page 10 of 59 LESSOR:______GOVERNMENT:______
Updated: March 10, 2022
Page 11 of 59 LESSOR:______GOVERNMENT:______
D-04c (Fire Ingress Door)
Secondary Suite Perimeter Delayed Door (Inswinging Door in the Path of Egress)
▪ 1-3/4” x 3’-0” x 6’-8” min. acoustical single solid wood or metal clad door (STC 45) with no windows or vents, and a continuously welded metal frame filled w/ sound deadening material (STC 45). Door and frame are to be prepped at the factory for the hardware listed below.
▪ Mechanical door closer, LCN 4040 series, installed secure side.
▪ Medeco M3 keyway, removable cylinder, key should be factory restricted level 7.
▪ Yale 7150 Exit Device with Delayed Egress and Trim Monitor Switch Part # 7150 (F if Fire Rated) x DO x (Door Width) x (Trim) x (Finish) x (Door Hand) Ex. 7150FDO-36 x Trim x Finish x Door Hand. Specify NFPA or BOCA according to local jurisdiction.
▪ Fuse power supply output to 1 AMP.
▪ Continuous hinge w/ a field serviceable, removable center section, ABH model A110HDC(HINGE
LENGTH: 83/85/95/120)TW8R (w/electric wire transfer option, 8 wire min. with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side.
▪ Door contacts to be F&I by Security Contractor with General Contractor F&I ¾” EMT conduit stub up with insulated bushings and pull string to General Contractor F&I 12”x12”x4” J-box above ceiling on secure side.
▪ In-door viewing device (DoorScope DS238 Metallic Ultra Wide Angle) & 3 door silencers.
▪ A single 4”x4” (1900 deep) electrical box with ¾ “ knock outs. The box shall be equipped with the appropriate sized single gang plaster ring. The size of the plaster ring shall be determined by the finished wall thickness.
▪ The single gang plaster ring shall be flush mounted to the finished wall surface. with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side
▪ Signage as noted: “ALARMED EMERGENCY EXIT. PUSH UNTIL ALARM SOUNDS. OPEN
DOOR IN 30 SECONDS. AREA UNDER SURVEILLANCE. SECURITY WILL RESPOND”
Updated: March 10, 2022
Page 12 of 59 LESSOR:______GOVERNMENT:______
D-04d Secondary Suite Single Perimeter ABAAS Egress Door - (Outward Swing):
▪ 1-3/4” x 3’-0” x 6’-8” min. acoustical single solid wood or metal clad door (STC 45) with no windows or vents, and a continuously welded metal frame filled with sound deadening material (STC 45). Door and frame are to be prepped at the factory for the hardware listed below.
▪ ANSI grade 1 lever action lockset, store room function, M3 keyway, removable cylinder, factory restricted key level 7.
▪ Electric strike, HES 9600 high security electric strike Fail Secure, with ¾ ” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” j-box above ceiling on secure side of the door.
▪ Door release device: A security grade emergency door release with key override, Von Duprin XP9975L-NL-F-(Finish)(size)(Handing).
▪ ABAAS approved electronic push style mount automatic door operator installed on secure side of door, with ¾ ” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” j-box above ceiling on secure side of the door.
▪ Example LCN 4640
▪ ABAAS approved DPDT hardwired handicap pushbutton/paddle on secure side of door no higher than 3’-8” on center A.F.F. with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” j-box above ceiling on secure side of the door.
▪ ABAAS approved signage on threat and secure side of door.
▪ 120vAC 20 amp circuit at door for hardwiring of automatic door operator.
▪ Heavy duty 5 knuckle hinges with non-removable pins.
▪ Door contacts to be F&I by Security Contractor with ¾ ” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” j-box above ceiling on secure side of the door.
▪ In-door viewing device (Door Scope brand).
▪ A single 4”x4” (1900 deep) electrical box with ¾” knock outs. The box shall be equipped with the appropriate sized single gang plaster ring. The size of the plaster ring shall be determined by the finished wall thickness.
▪ The single gang plaster ring shall be flush mounted to the finished wall surface. with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side.
▪ (1) Floor mounted stop and (3) door silencers.
Note: If door is existing and needs to be modified, consult EOUSA for direction on how to proceed.
Page 13 of 59 LESSOR:______GOVERNMENT:______
Updated: March 10, 2022
Page 14 of 59 LESSOR:______GOVERNMENT:______
D-05 SPR (Secure Processing Room) Door:
▪ 1-3/4” x 3’-0” x 6’-8” min. Ambico acoustical single solid wood core, wood staved door or metal door with no windows or vents, and a continuously welded metal frame filled with sound deadening material to meet a minimum STC of 51. Door and frame are to be procured as an assembly, prepped at the factory for the hardware listed below and installed per the manufacturer’s recommendations to achieve a minimum STC of 51.
▪ GSA approved 3 position combination deadbolt lock, such as a Kaba Mass X-10 for in-Swing doors with part number CDX-10 (or X-10 High Security Pedestrian Exit Device on out-Swings.)
Must be installed by a Kaba Mass X-10 certified installer, according to the manufacturer’s installation instructions, mounted ‘3-11” (47”) maximum, to the center of the lock.
▪ Mechanical door closer, LCN 4040 series, installed secure side.
▪ Stainless steel cam lift hinges.
▪ Door contacts to be F&I by Security Contractor with General Contractor F&I ¾” EMT conduit stub up with insulated bushings and pull string to General Contractor F&I 12”x12”x4” J-box above ceiling on secure side.
▪ Simplex L1000 (MODEL 1021) w/key override.
▪ Medeco M3 keyway, removable cylinder, key should be factory restricted level 7.
▪ Mechanical door sweep and continuous screw-on metal and rubber sound gasket, around entire door frame, to achieve a minimum STC of 50.
▪ (1) Floor mounted stop.
▪ (1) Threshold.
See Diagram next page and attached enlargements.
Page 15 of 59 LESSOR:______GOVERNMENT:______
D-05a SPR (Secure Processing Room) Door with Electronic Access Control:
▪ 1-3/4” x 3’-0” x 6’-8” min. single solid wood core wood staved door (STC 50) with no windows or vents, and a continuously welded metal frame filled with sound deadening material (STC 50).
Door and frame are to be prepped at the factory for the hardware listed below.
▪ GSA approved 3 position combination deadbolt lock, such as a Kaba Mass X-10 for in-Swing doors with part number CDX-10 (or X-10 High Security Pedestrian Exit Device on out-Swings) X- 10 must be installed by a factory certified installer, according to manufacturer’s installation instructions
▪ Mechanical door closer, LCN 4040 series, installed secure side.
▪ A single 4”x4” (1900 deep) electrical box with ¾ “ knock outs. The box shall be equipped with the appropriate sized single gang plaster ring. The size of the plaster ring shall be determined by the finished wall thickness.
▪ The single gang plaster ring shall be flush mounted to the finished wall surface. with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side.
▪ Medeco M3 keyway, removable cylinder, key should be factory restricted level 7.
▪ Electrified Mortise Lockset, Corbin Russwin ML20905-NSV-630-M92-24D Fail Secure w/VR trim.
▪ Stainless steel camlift hinges.
▪ Door contacts furnished and installed by Security Contractor with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side.
▪ Mechanical door sweep and continuous screw-on metal and rubber sound gasket, around entire door frame, to achieve an STC 50.
Updated: March 10, 2022
Page 16 of 59 LESSOR:______GOVERNMENT:______
D-05b SPR (Secure Processing Room) Door Exit Only:
▪ 1-3/4” x 3’-0” x 6’-8” min. single solid wood core wood staved door (STC 50) with no windows or vents, and a continuously welded metal frame filled with sound deadening material. Door and frame are to be prepped at the factory for the hardware listed below.
▪ GSA approved 3 point locking device (Von Duprin 9857EOF), no hardware on threat side
▪ Mechanical door closer, LCN 4040 series, installed secure side.
▪ Stainless steel cam lift hinges.
▪ Door contacts furnished and installed by Security Contractor with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side.
▪ Mechanical door sweep and continuous screw-on metal and rubber sound gasket, around entire door frame, to achieve an STC 50.
Updated: March 10, 2022
Page 17 of 59 LESSOR:______GOVERNMENT:______
D-05C SPR (Secure Processing Room) Door w/RF Protection:
▪ 1-3/4” x 3’-0” x 6’-8” min. Ambico single galvanneal door with stainless steel edge caps solid (STC 50) with no windows or vents, and a continuously welded metal frame filled with sound deadening material. Door and frame are to be prepped at the factory for the hardware listed below.
▪ RF foam seals around entire door frame
▪ Acoustic and RF bronze seal around entire door frame
▪ GSA approved 3 position combination deadbolt lock, such as a Kaba Mass X-10 for in-Swing doors with part number CDX-10 (or X-10 High Security Pedestrian Exit Device on out-Swings) X- 10 must be installed by a factory certified installer, according to manufacturer’s installation instructions
▪ Mechanical door closer, LCN 4040 series, installed secure side.
▪ Stainless steel cam lift hinges.
▪ Door contacts to be F&I by Security Contractor with General Contractor F&I ¾” EMT conduit stub up with insulated bushings and pull string to General Contractor F&I 12”x12”x4” J-box above ceiling on secure side.
▪ Simplex L1000 (MODEL 1021) w/key override.
▪ Medeco M3 keyway, removable cylinder, key should be factory restricted level 7.
▪ Mechanical door sweep and continuous screw-on metal and rubber sound gasket, around entire door frame, to achieve a minimum STC of 50.
Updated: March 10, 2022
Page 18 of 59 LESSOR:______GOVERNMENT:______
D-06
Typical Single Interior Door for United States Attorneys/Chief’s Office/Conference Room/Trial Prep/Main Copy Room:
▪ 1-3/4” x 3’-0” x 6’-8” min. single solid wood door w/ metal frame (STC 45).
▪ Medeco Bilevel standard cylinder lockset.
▪ Mechanical door sweep and continuous screw-on sound gasket to achieve an STC 45.
▪ (1) Floor mounted stop, (3) silencers, (1) coat hook (as required).
Note: Main Conference Rooms may have a double door configuration as decided by EOUSA on a case-by-case basis.
The Inactive Door Leaf shall have the following additional hardware:
* 1 – ¾” x 3’ – 0” x 6’ – 8” min. single solid wood door leaf as the inactive leaf.
* Building standard latch mortised into inactive leaf.
* Mechanical door sweep and continuous screw-on sound gasket to achieve an STC 45.
* Continues 3/8” x 1’ x 6’ – 8” min. hard-wood astragal, stained to match door finish.
* Building Standard Flush Bolts, top and bottom of inactive door leaf.
D-07 Typical Single Interior Door for Interior Offices, AUSA Offices/Break Rooms/Storage at Interior Suite/Secondary Copy Rooms:
▪ 1-3/4” x 3’-0” x 6’-8” min. single solid wood door w/ metal frame or building standard if equivalent.
▪ Medeco Bilevel standard cylinder lockset.
▪ (1) Floor mounted stop, (3) silencers, and (1) coat hook (as required).
D-08 Typical Single Interior Door for Conference Room at Tenant Shared Unsecured Corridor:
▪ 1-3/4” x 3’-0” x 6’-8” min. single solid wood door w/ metal frame (STC 45).
▪ Mechanical door closer, LCN 4040 series, installed secure side.
▪ Simplex L1000 (MODEL 1021) w/key override.
▪ In-door viewing device (DoorScope DS238 Metallic Ultra Wide Angle).
▪ Mechanical door sweep and continuous screw-on sound gasket to achieve an STC 45.
▪ (1) Floor mounted stop.
Note: This configuration may be used when the conference room is not a part of the main secure perimeter – Only use if there is no access to USAO space through the conference room. Main Conference Rooms may have a double door configuration as decided by EOUSA on a case-by-case basis. The double door configuration shall have separate hardware and requirements. Vertical deadbolts on each inactive leaf/door will be necessary for double door tenant shared corridor.
D-08a Typical Single Interior Door at the corridor for SPR Vestibule:
▪ 1-3/4” x 3’-0” x 6’-8” min. single solid wood door w/ metal frame (STC 45).
▪ Mechanical door closer, LCN 4040 series, installed secure side.
▪ Simplex L1000 (MODEL 1021) w/key override.
▪ Mechanical door sweep and continuous screw-on sound gasket to achieve an STC 45.
D-09 Not Used.
D-10 Typical Single/Double Door for Storage at Unsecured Corridor:
▪ 1-3/4” x 3’-0” x 6’-8” min. single solid wood door(s) w/ metal frame.
▪ Mechanical door closer(s), LCN 4040 series, installed secure side.
▪ Simplex L1000 (MODEL 1021) w/key override.
▪ In-door viewing device (DoorScope DS238 Metallic Ultra Wide Angle).
▪ Floor mounted stop, (3) silencers per door.
Page 19 of 59 LESSOR:______GOVERNMENT:______
D-11 Typical Single Interior Door for Workroom (inside or beside ADP room):
▪ 1-3/4” x 3’-0” x 6’-8” min. single solid wood door w/ metal frame.
▪ Simplex L8148 lock with deadbolt and key override.
▪ Mechanical door closer, LCN 4040 series, installed secure side.
▪ Floor mounted stop.
D-12
Typical Single/Double Closet Doors
▪ Single/Double hollow wood door w/ frame or building standard if equivalent.
▪ Building standard passage set.
▪ Floor mounted stop and (3) silencers per door.
D-13 Typical Single Interior Door for IDF (Independent Distribution Frame) Room:
▪ 1-3/4” x 3’-0” x 6’-8” min. single louvered hollow wood door w/ metal frame.
▪ Simplex L1000 (MODEL 1021) w/key override.
▪ Mechanical door closer, LCN 4040 series.
▪ Floor mounted stop.
D-14 Typical Single Interior Door for Electrical Closet:
▪ 1-3/4” x 3’-0” x 6’-8” min. single solid core door w/ metal frame.
▪ Medeco Bilevel standard cylinder lockset.
▪ (1) Floor mounted stop and (3) door silencers.
D-15 Typical Single Interior Door for Secure Storage:
▪ 1-3/4” x 3’-0” x 6’-8” min. solid wood or metal clad door with no windows or vents, and a continuously welded metal frame. Door and frame are to be prepped at the factory for the hardware listed below.
▪ GSA approved 3 position combination deadbolt lock, such as a Kaba Mass X-10 with 03 Strike KIT001 for in swinging doors (part number CDX-10 w/o3), or model MH Exit Device, Mech High SEC001 for out swinging doors (part number 511037). Must be installed by a Kaba Mass X-10 certified installer, according to the manufacturer’s installation instructions.
▪ ANSI grade 1 storeroom function lever action lockset, with Medeco M3 Keyway. Kew will be factory restricted level 7.
▪ Mechanical door closer, LCN 4040 series, installed secure side.
▪ Door contacts to be F&I by Security Contractor with General Contractor F&I ¾” EMT conduit stub up with insulated bushings and pull string to General Contractor F&I 12”x12”x4” J-box above ceiling on secure side.
▪ (1) Floor mounted stop and (3) door silencers.
Page 20 of 59 LESSOR:______GOVERNMENT:______
D-16 Secondary Suite Perimeter – Double Doors w/ Mullion – Single Ingress/Single Egress:
▪ 1-3/4” x 3’-0” x 6’-8” min. solid wood or metal clad doors with no windows or vents, continuously welded full metal frame (4 sides) and removable central mullion.. Outward swinging from USAO.
Doors and frame are to be prepped at the factory for the hardware listed below.
▪ (2) Mechanical door closers, LCN 4040 series, installed secure side.
▪ Door bolts (S&G SM1881) to be installed top and bottom of inactive door leaf.
▪ Door Release Device: A security grade emergency door release device with a key over ride. Outside trim is lever action, electric locking. This device must remain latched in the fail secure (FSE) condition. Von Duprin RX-XP99-LxE996-(Finish)-(size)-24VDC. Medeco M3 keyway, removable cylinder, key should be factory restricted level 7. Request to exit sensor incorporated into the push-bar from the factory- not as an after- market installation.
▪ Roller Strike for Von Duprin XP 99 Rim Exit: Von Duprin Roller Strike 909.
▪ (2) Continuous hinges, w/ a field serviceable, removable center section, ABH model A110HDC (HINGE
LENGTH: 83/85/95/120)TW8R (w/electric wire transfer option, 8-wire min. with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side.
▪ Door contacts to be F&I by Security Contractor with General Contractor F&I ¾” EMT conduit stub up with insulated bushings and pull string to General Contractor F&I 12”x12”x4” J-box above ceiling on secure side.
▪ (1) Astragal (Active Door Only).
▪ A single 4”x4” (1900 deep) electrical box with ¾ “ knock outs. The box shall be equipped with the appropriate sized single gang plaster ring. The size of the plaster ring shall be determined by the finished wall thickness.
▪ The single gang plaster ring shall be flush mounted to the finished wall surface. with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side.
▪ In-door viewing device (DoorScope DS238 Metallic Ultra Wide Angle).
▪ (3) Silencers per door.
Page 21 of 59 LESSOR:______GOVERNMENT:______
D-17 (similar to D-16 diagram) Secondary Suite Perimeter – Double Doors w/ Mullion – Single Ingress/Double Egress:
▪ 1-3/4” x 3’-0” x 6’-8” min. solid wood or metal clad doors with no windows or vents, continuously welded full metal frame (4 sides) and a removable central mullion. Outward swinging from USAO. Doors and frame are to be prepped at the factory for the hardware listed below.
▪ (2) Mechanical door closers, LCN 4040 series, installed secure side.
▪ (1) Ingress door, Von Duprin Fail Secure (FSE) RX-XP99-LxE996-(Finish)-(Size)-24VDC.
Medeco M3 keyway, key over ride, removable cylinder, Factory restricted key, level 7.
▪ (1) Egress door, Von Duprin RX-XP99-Lx996, Medeco M3 keyway, key over ride, removable cylinder, Factory restricted key, level 7. Request exit sensor to be incorporated into the push-bar from the factory, not as an aftermarket installation. Needs mullion and two VD 909 roller strikes.
▪ (1)Door Loops by SDC or Keedex part no. (SDC) PT-2U or (Keedex) K-DLA. (Active Door only)
▪ (2) Continuous hinges w/ a field serviceable, removable center section, ABH model A110HDC
(HINGE LENGTH: 83/85/95/120)TW4R (w/electric wire transfer option, 4-wire min. with (2) ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side.
▪ Door contacts to be F&I by Security Contractor with General Contractor F&I ¾” EMT conduit stub up with insulated bushings and pull string to General Contractor F&I 12”x12”x4” J-box above ceiling on secure side.
▪ In-door viewing device in both doors (DoorScope DS238 Metallic Ultra Wide Angle).
▪ A single 4”x4” (1900 deep) electrical box with ¾ “ knock outs. The box shall be equipped with the appropriate sized single gang plaster ring. The size of the plaster ring shall be determined by the finished wall thickness.
▪ The single gang plaster ring shall be flush mounted to the finished wall surface with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side.
▪ (3) Silencers per door.
Updated: March 10, 2022
Page 22 of 59 LESSOR:______GOVERNMENT:______
D-18 Typical Fire Stairwell Door Opening into the Stairwell directly from USAO space:
▪ 1-3/4” x 3’-0” x 6’-8” min. (Fire Rated) solid wood or metal clad door with no windows or vents, and a continuously welded metal frame or Building Standard Fire Stairwell door. Outward swinging from USAO. Door and frame are to be prepped at the factory for the hardware listed below.
▪ Mechanical door closer, LCN 4040 series, installed secure side.
▪ Door release device: A security grade emergency door release device with a key over ride.
Outside trim is lever action, electric locking. This device must remain latched in the fail secure (FSE) condition, unless dictated fail safe (FS) by local fire code. Von Duprin RX-XP99-F- LxE996-(Finish)-(size)-24VDC – Medeco M3 keyway, key over ride, removable cylinder, Factory restricted key, level 7.
▪ Roller Strike for Von Duprin XP 99 Rim Exit: Von Duprin Roller Strike 909.
▪ Continuous hinge w/ a field serviceable, removable center section, ABH model A110HDC
(HINGE LENGTH: 83/85/95/120)TW4R (w/electric wire transfer option, 4 wire min. with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side).
▪ Door contacts to be F&I by Security Contractor with General Contractor F&I ¾” EMT conduit stub up with insulated bushings and pull string to General Contractor F&I 12”x12”x4” J-box above ceiling on secure side.
▪ A single 4”x4” (1900 deep) electrical box with ¾ “ knock outs. The box shall be equipped with the appropriate sized single gang plaster ring. The size of the plaster ring shall be determined by the finished wall thickness.
▪ The single gang plaster ring shall be flush mounted to the finished wall surface. with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side.
▪ (3) Door silencers.
See Diagram on next page and attached enlargements.
Page 23 of 59 LESSOR:______GOVERNMENT:______
Updated: March 10, 2022
Page 24 of 59 LESSOR:______GOVERNMENT:______
D-19 Typical Organized Crime Drug Enforcement Task Force (OCDETF) Door:
▪ 1-3/4” x 3’-0” x 6’-8” min. solid wood or metal clad door with no windows or vents, and a continuously welded metal frame. Door and frame are to be prepped at the factory for the hardware listed below.
▪ Mechanical door closer, LCN 4040 series, installed secure side.
▪ Simplex L1000 (MODEL 1021) w/key override.
▪ Continuous screw-on sound gasket and Mechanical Door Sweep.
▪ (1) Floor mounted stop.
D-20 Fire Stairwell Door. Exit Only from USAO space into stairwell:
▪ 1-3/4” x 3’-0” x 6’-8” min. (Fire Rated) solid wood or metal clad door with no windows or vents, and a continuously welded metal frame or Building Standard Fire Stairwell door. Outward swinging from USAO. Door and frame are to be prepped at the factory for the hardware listed below.
▪ Mechanical door closer, LCN 4040 series, installed secure side.
▪ Door release device: A security grade emergency door release, no key over ride. Von Duprin
RX-XP99-F-Lx996L-DT-(Finish)-(size). Request to exit sensor incorporated into the push-bar from the factory, not as an after-market installation.
▪ Continuous hinge w/ a field serviceable, removable center section, ABH model A110HDC(HINGE LENGTH: 83/85/95/120)TW4R (w/electric wire transfer option, 4 wire min. with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side.
▪ Door contacts to be F&I by Security Contractor with General Contractor F&I ¾” EMT conduit stub up with insulated bushings and pull string to General Contractor F&I 12”x12”x4” J-box above ceiling on secure side.
D-21 Fire Stairwell Door. Night Latch - Free Exit / keyed entry from Stairwell into USAO Space:
▪ 1-3/4” x 3’-0” x 6’-8” min. (Fire Rated) solid wood or metal clad door with no windows or vents, and a continuously welded metal frame or Building Standard Fire Stairwell door. Outward swinging from USAO. Door and frame are to be prepped at the factory for the hardware listed below.
▪ Mechanical door closer, LCN 4040 series, installed secure side.
▪ Door release device: A security grade emergency door release with a key over ride. Von Duprin
RX-XP99-F-Lx992L-(Finish)-(size). Medeco M3 keyway, removable cylinder, key should be factory restricted level 7. Request to exit sensor incorporated into the push-bar from the factory, not as an after-market installation.
▪ Continuous hinge w/ a field serviceable, removable center section, ABH model A110HDC (HINGE LENGTH: 83/85/95/120)TW4R (w/electric wire transfer option, 4 wire with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side.
▪ Door contacts to be F&I by Security Contractor with General Contractor F&I ¾” EMT conduit stub up with insulated bushings and pull string to General Contractor F&I 12”x12”x4” J-box above ceiling on secure side.
▪ (3) Door silencers.
D-22 Typical Single Perimeter Door for Unstaffed Office (Trial Prep Space Retained in Courthouse):
▪ 1-3/4” x 3’-0” x 6’-8” min. single solid wood door w/ metal frame (STC 45).
▪ Mechanical door closer, LCN 4040 series, installed secure side.
▪ Simplex L1000 (MODEL 1021) w/key override.
▪ In-door viewing device (DoorScope DS238 Metallic Ultra Wide Angle).
▪ Mechanical door sweep and continuous screw-on sound gasket to achieve an STC 45.
▪ (1) Floor mounted stop
Updated: March 10, 2022
Page 25 of 59 LESSOR:______GOVERNMENT:______
D-23 Secondary Suite Perimeter – Double Door w/o Mullion – Single Delayed Ingress / Single Egress:
▪ 1-3/4” x 3’-0” x 6’-8” min. single solid wood or metal clad doors with no windows or vents w/ continuously welded metal frame. Door and frame are to be prepped at the factory for the hardware listed below.
▪ (2) Mechanical door closers, LCN 4040 series, installed secure side.
▪ Egress (into secure side) devise, Yale 7150(F if Fire Rated)DO (Door Width) x Lever Style 627F x
Finish x Door Hand.
▪ Egress (into threat side) devise, exit only devise, Von Duprin RX9847-WDCEO.
▪ Power supply, Von Duprin PS873BK-FA.
▪ (2) Continuous hinges w/ a field serviceable, removable center section, ABH model A110HDC
(hinge length: 83/85/95/120) TW8R (w/ electric wire transfer option, 8 wire min. with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side.
▪ Door contacts to be F&I by Security Contractor with General Contractor F&I ¾” EMT conduit stub up with insulated bushings and pull string to General Contractor F&I 12”x12”x4” J-box above ceiling on secure side.
▪ In-door viewing device (DoorScope DS238 Metallic Ultra Wide Angle) egress door side only.
▪ A single 4”x4” (1900 deep) electrical box with ¾ “ knock outs. The box shall be equipped with the appropriate sized single gang plaster ring. The size of the plaster ring shall be determined by the finished wall thickness.
▪ The single gang plaster ring shall be flush mounted to the finished wall surface. with ¾” EMT conduit stub up with insulated bushings and pull string to 12”x12”x4” J-box above ceiling on secure side.
▪ (2) Floor mounted stops.
▪ Signage (mounted on ingress door only) as noted: “ALARMED EMERGENCY EXIT. PUSH
UNTIL ALARM SOUNDS. OPEN DOOR IN 30 SECONDS. AREA UNDER SURVEILLANCE.
SECURITY WILL RESPOND”.
Note: See drawing next page for signage layout.
D-24 Fire Stairwell Door. Night Latch - Free Entry /Exit from Secure USAO Stairwell:
▪ 1-3/4” x 3’-0” x 6’-8” min. (Fire Rated) solid wood or metal clad door with no windows or vents, and a continuously welded metal frame or Building Standard Fire Stairwell door. Outward swinging from USAO. Door and frame are to be prepped at the factory for the hardware listed below.
▪ Mechanical door closer, LCN 4040 series, installed secure side.
▪ Door release device: A security grade emergency door release with a key over ride. Von Duprin
XP99-F-99L-BE (Finish)-(size). Medeco M3 keyway, removable cylinder, key should be factory restricted level 7.
Page 26 of 59 LESSOR:______GOVERNMENT:______
ALARMED EMERGENCY
EXIT. PUSH UNTIL ALARM
SOUNDS. OPEN DOOR IN
30 SECONDS. AREA
UNDER SURVEILLANCE.
SECURITY WILL RESPOND.
TWO VERTICAL RODS - DOUBLE EGRESS
EGRESS
SECURE SIDE
EGRESS
THREAT SIDE
Updated: March 10, 2022
Page 27 of 59 LESSOR:______GOVERNMENT:______
ABAAS – Access Control Interface
Page 28 of 59 LESSOR:______GOVERNMENT:______
Updated: March 10, 2022
Page 29 of 59 LESSOR:______GOVERNMENT:______
General Door Notes
1. All hardware shall be installed in accordance with ABA Accessibility Standards. Standard office doors are to have Medeco Bilevel standard cylinders, provided with six-pin, paracentric, compliant with ANSI/BHMAA 156 standards.
2. GC to perform necessary testing, as well as all internal connections and adjustments for all door hardware power connections and request to exit (RX or REX) switches. The GC will also connect these devices to the door side of the wired hinge. The Security contractor will connect to electronic hinge. The GC will supply GSA and FMSS with wiring diagrams, identifying by color and polarity wires for power and Rex connections at the wired hinge 1 week before door hardware installation begins.
Wiring will be done in a uniform manner.
3. Medeco-3 key cylinders can only be purchased by the General Contractor with a letter of permission from the United States Attorney’s office on USAO letterhead. The cylinders must be delivered directly to a representative of the USAO. The representative shall then hand-deliver the cylinders to the GC for installation. USAO must maintain a physical chain of custody by directly supervising the installation of the Medeco-3 key cylinders.
4. All Medeco cylinders must be purchased by an authorized Medeco dealer.
5. All door hardware must be installed by a licensed, qualified locksmith/door hardware installer with a proven track record of installing the type of door hardware we specify. Installations done by anyone or any company that does not meet this requirement will not be accepted.
6. USAO Facilities Lockset finish preference is anodized aluminum. All door hardware finishes to match.
7. Documentation of manufacturer’s factory STC tests, verifying the door assemblies, with hinges and screw-on sound gaskets, etc., meet the minimum STC requirements for STC rated doors STC 45 and
STC 50.
8. USAO Door Finish shall be Stain Grade unless otherwise indicated.
9. “Outward Swing” shall refer to a door which swings out from the USAO secure perimeter/suite.
10. All metal door frames that are designated to be welded shall be done so with continuous welds.
11. If door hardware is Fail Safe, then the General Contractor shall have the Fire Alarm Company provide a relay on the Fire Panel to the door.
12. All door contacts on wood and metal doors that are not ballistic rated shall be surface mounted.
13. All junction boxes and conduit for access control doors must be mounted and ran on the secure side of the door.
14. See link below for Simplex Specifications.
15. All ballistic doors are to be manufactured by North American Bulletproof, San Antonio, TX
(http://shotgard.com/) 210.225.0982.
a. http://www.kaba-ilco.com/access_control/index.aspx http://www.kaba-ilco.com/access_control/index.aspx
Updated: March 10, 2022
Page 30 of 59 LESSOR:______GOVERNMENT:______
WALL TYPES
WT-01
Suite Demising Wall (slab to slab STC 45):
▪ Minimum 3-5/8" 16 gauge Studs
▪ 9 Gauge AMICO 1.5-9F Medium Security
Mesh, attached to studs per manufacturer’s specifications (Not Required in Courthouse Projects, Federal Buildings or along full height Conc. or block walls)
▪ Minimum 5/8" Gypsum Wallboard (both sides)
▪ Sound Attenuation Batt Insulation
WT-01A
Suite Demising Wall (slab to slab STC 45):
▪ Minimum 3-5/8" 16 gauge Studs
▪ 5/8” Plywood (Class C or higher) (Threat Side) glued and screwed to studs with staggered joints (Not required in Courthouse projects, Federal Buildings or along full height concrete or CMU walls)
▪ Minimum 5/8" Gypsum Wallboard (both sides) Stagger Gyp. Bd. to prevent Continuous seams
Page 31 of 59 LESSOR:______GOVERNMENT:______
WT-02
Ballistic Wall @ Waiting Area (slab to slab STC 45):
▪ Minimum 3-5/8" 16 gauge Stud
▪ Level 3 Rated Ballistic Wall Paneling
▪ Minimum 5/8" Gypsum Wallboard (both sides)
▪ Level 3 batten strips over seams
Note: Install UL752, Level 3 rated ballistic wall paneling, material to be mounted slab-to-slab within finished partitions available from North American Bulletproof, San Antonio, TX (http://shotgard.com/) 210.225.0982; or by Safeguard Security Services, Ltd. San Antonio, TX 1- 800-880-8306 or 210-661-8306 (www.armortex.com/products.html) (or approved equal).
WT-02A
Ballistic Wall – Firearms Room @ Waiting Area (Slab to Slab):
• Minimum 3-5/8” 16 gauge stud
• UL Standard 752 Level 3 Rated Ballistic Wall
Paneling – ballistic paneling on the secure side
(all walls, floor, and ceiling)
• Minimum 5/8” Gypsum Wallboard (both sides)
• 3-½” Sound Attenuation Batt Insulation to achieve
STC 45 wall sound level rating. Continuous batts to go full height of the wall
Page 32 of 59 LESSOR:______GOVERNMENT:______
Page 33 of 59 LESSOR:______GOVERNMENT:______
WT-03
USA Office/Chief’s Office/Conference Rooms/Break Rooms/Main Copy Room/Deposition/Interview and Trial Prep Spaces Wall (slab to slab STC 45):
▪ Minimum 3-5/8" 20 gauge Stud
▪ Minimum 5/8" Gypsum Wallboard (both sides)
▪ Sound Attenuation Batt Insulation
▪ For WT-3A:
o 2’-0” clerestory window with 3/8” tempered glass o Hollow metal frame o Trim optional
▪ For WT-3B:
o 3/8” floor to ceiling tempered glass panel o Hollow metal frame
Page 34 of 59 LESSOR:______GOVERNMENT:______
WT-04
ADP/Computer Room Wall (slab to slab
STC45):
▪ Minimum 3-5/8" 20 gauge Stud
▪ Vapor Barrier
▪ Minimum 5/8" Gypsum Wallboard
(threat sides)
▪ 5/8” Plywood painted. Fire rating label unpainted (Class C or higher) (Secure Side)
WT-05
Typical Interior Wall (to underside of ceiling):
▪ Minimum 3-5/8" 20 gauge Stud
▪ Minimum 5/8" Gypsum Wallboard (both sides)
▪ For WT-5A:
o 2’-0” clerestory window with 3/8” tempered glass o Hollow metal frame o Trim optional
▪ For WT-5B:
o 3/8” floor to ceiling tempered glass panel o Hollow metal frame
Page 35 of 59 LESSOR:______GOVERNMENT:______
WT-06
Secure Processing Room Wall/ Secure Storage Room Wall (slab to slab min. STC 50):
▪ Minimum 3-5/8" 16 gauge Studs
▪ 5/8” Plywood (Class C or higher) (Secure
Side) glued & screwed to studs w/ staggered joints
▪ 3 ½” Sound Attenuation Batt Insulation to achieve STC 50 wall sound level rating.
Continuous batts to go full height of the wall.
▪ Minimum 5/8" Gypsum Wallboard (1-Layer of Gyp Bd on Threat side) (1-Layer of Gyp Bd on Secure side Stagger Gyp BD to prevent continuous seams. Use aluminum tape on all aluminum seams and joints of first layer of foil backed gyp. bd. Foil backed gypsum bd. to be installed aluminum face-to-aluminum face.
▪ Foil-Backed Acoustical Ceiling Tiles, unless floors are made of metal deck construction.
WT-06F
Secure Processing Room Wall/ Secure Storage Room Wall W/ RF Protection (slab to slab min. STC 50):
▪ Minimum 3-5/8" 16 gauge Studs
▪ 5/8” Plywood (Class C or higher) (Secure Side) glued & screwed to studs w/ staggered joints
▪ 3 ½” Sound Attenuation Batt Insulation to achieve STC 50 wall sound level rating.
Continuous batts to go full height of the wall.
▪ Minimum 5/8" Gypsum Wallboard (1-Layer of Gyp Bd on Threat side) Stagger Gyp BD and plywood to prevent continuous seams.
▪ 5/8” Quiet Rock 530 RF BD (Foil-Backed) Secure Side.
Use aluminum tape on all aluminum seams.
Apply drywall tape over aluminum tape. Provide level 4 finish.
▪ Foil-Backed Acoustical Ceiling Tiles, unless floors are made of metal deck construction.
Page 36 of 59 LESSOR:______GOVERNMENT:______
WT-07
Locker / Shower Room Wall (slab to slab
STC 45):
▪ Minimum 3-5/8" 20 gauge Stud
▪ Minimum 5/8” Moisture Resistant
Gypsum Wallboard (Locker / Shower Room side)
▪ Minimum 5/8" Gypsum Wallboard (Office side)
WT-07a Shower Area & Toilet Room Wall:
▪ Minimum 3-5/8" 20 gauge Stud
▪ Minimum 5/8” Cementitious Tile
Backer Board (Shower Room side)
▪ 4 ½” x 4 ½” or 6” x 6” Glazed
Ceramic Tile (Up to the ceiling in shower areas, 42” A.F.F. in toilet areas)
▪ Minimum 5/8" Moisture Resistant Gypsum Wallboard
Updated: March 10, 2022
Page 37 of 59 LESSOR:______GOVERNMENT:______
WT-08
Ballistic Secure Perimeter Wall (slab to slab min. STC 45):
▪ Minimum 3-5/8" 14 gauge Studs
▪ Level 8 Ballistic Wall Paneling
(Secure Side) 5/8” Plywood (Class C or higher) (Secure Side) glued and screwed to studs with staggered joints
▪ 3 ½” thick Sound Attenuation Batt Insulation to achieve STC 45 wall sound level rating. continuous batts to go full height of the wall.
▪ Minimum 5/8" Gypsum Wallboard
(1-Layer of Gyp Bd on Threat side) (1-Layer of Gyp Bd on Secure side Stagger Gyp BD to prevent continuous seams)
Page 38 of 59 LESSOR:______GOVERNMENT:______
General Wall Notes
1. All Partitions shall be taped, bedded, and finished to a smooth wall texture, painted with one prime coat and one finish coat.
2. To minimize sound transmission through a wall, outlets should not be placed back to back. Outlets, conduit, and data jacks in SPR’s shall be surface mounted.
3. In SPR’s that require Foil-Backed Gypsum Board for RF protection, that gypsum board shall have the RF Foil factory incorporated into the gypsum board itself.
This is the start of the file's text. The full file is on GovTribe.