This document is an Exhibit C - Statement of Qualifications Requirements for a Design-Build project by the City of St. Petersburg, Florida, specifically for the NEWRF & NWWRF PCCP Replacement (Project No. 23109-100). The document outlines comprehensive submittal requirements for contractors interested in this water infrastructure replacement project, which involves replacing approximately 7,000 linear feet of 36" Pre-stressed Concrete Cylinder Pipe (PCCP) from the Northeast Water Reclamation Facility and about 15,286 linear feet of 30" PCCP reclaimed water main from the Northwest Water Reclamation Facility. Contractors must prepare a 75-page PDF Statement of Qualifications that addresses multiple sections including project team composition, key personnel details, reference projects, firm qualifications, project approach, technology capabilities, and other required documentation.
The submittal requirements are highly structured, with specific page limitations for each section and detailed instructions for presenting information. Contractors must demonstrate relevant experience through five reference projects each exceeding $15,000,000, provide comprehensive details about their project team and key personnel, and include information about their technological capabilities, network security, and records retention. The document also requires contractors to disclose any prior contractual failures, provide business outreach plan details regarding minority/women/disadvantaged business enterprise certifications, and submit current applicable Florida licenses. The evaluation appears focused on technical competence, experience, and organizational capabilities rather than immediate pricing, with an emphasis on the contractor's ability to successfully execute complex water infrastructure replacement projects.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Rev: 08/09/23 Page 1(A) of 4(A)
Exhibit C - Statement of Qualifications Requirements – Addendum No. 1 Design-Build
NEWRF & NWWRF PCCP Replacement City of St. Petersburg, Florida
Project No. 23109-100
The Request for Qualifications shall include the following information in the order listed. Upload all responses as one PDF labeled “Statement of Qualifications Requirements”. The PDF shall be limited to 75 pages.
A. Submittal Requirements
Section Page Maximum
Transmittal Letter 1 Table of Contents/PDF Bookmarks 1 Project Team 10 Organization Chart 1 Other Firms 5 Key Personnel 10 Reference Projects 10 Firm Specific Qualifications 4 Project Approach 4 References 2 Network Security and Records Retention 4 Technology Capabilities 4 Contractual Failures No Maximum Business Outreach Plan 1 Licenses No Maximum Maximum Number of Pages for SOQ Responses 75*
*Proposals in excess of 75 pages may be deemed non-responsive by the Procurement and Supply Management Director.
B. Transmittal Letter
Contractors must submit a transmittal letter (maximum one page) on the firm’s letterhead. It must be signed by a representative of the Contractor who is authorized to sign such material and to commit the Contractor to the obligations contained in the offer. The transmittal letter must include the name, title, address, phone number and e-mail address for the Contractor’s contact, and must specify the firm’s signatory to any contract documents executed with the City. The transmittal letter may include other information deemed relevant by the Contractor.
C. Table Of Contents/PDF Bookmarks
Include a Table of Contents and Bookmark each section of the PDF.
Rev: 08/09/23 Page 2(A) of 4(A)
D. Project Team
In this section the Contractor must describe the composition, organization and management of the project team including:
1. Identifying all major sub-consultants and their responsibilities,
2. Demonstrating the firm’s ability to work cooperatively with multiple clients and sub-consultants, and
3. Identifying key individuals who would be assigned to the project and their roles and responsibilities.
E. Organization Chart
Provide an organization chart showing:
1. Reporting relationships and responsibilities of the Contractor and any other firms.
2. Reporting relationships and responsibilities of all key personnel (along with their firm affiliations).
F. Other Firms
Identify any other firms (such as subconsultants and subcontractors) included on the project team and describe the scope of work for each firm’s services and responsibilities throughout the project. Describe the firm’s approach to the management of subconsultants and subcontractors.
G. Key Personnel
1. Identify all key personnel (and their firm affiliations) on the project team and describe their specific responsibilities throughout the project.
2. Describe the Contractor’s approach to managing such key personnel.
3. Indicate the commitment of all key personnel in terms of an estimated percentage of available time for each throughout the project.
4. The proposed project manager and the proposed substitute shall each have a minimum of ten (10) years of applicable experience and shall remain with the projects throughout the term of the City’s base agreement. The project manager shall not be replaced or substituted without the prior written approval of the City. The City may request a personal interview with the short-listed firms’ proposed project managers. The key project manager or their approved substitutes shall be available for all meetings. Experience included on the resume must be limited to projects completed within the past ten (10) years.
5. Provide resumes for all key personnel in the SOQ. Limit resumes to one page per individual and include: (a) academic and professional qualifications, (b) professional registration (as applicable), (c) experience as it relates to the project and to the individual’s specified role on the project, (d) number of years with current firm and total number of years of experience, (e) primary office location.
H. Reference Projects
Describe the performance history and experience of the project team on similar projects.
The information should demonstrate the firm’s ability to work cooperatively with multiple clients
Rev: 08/09/23 Page 3(A) of 4(A) and any third-party. Submit five (5) reference projects that demonstrate relevant experience, each project with a cost in excess of $15,000,000. Each project description shall contain the following information:
1. Name of owner.
2. Owner reference and contact information.
3. Role of Contractor.
4. Contract value.
5. Year started and year completed.
6. Description of the project showing relevance to this project.
7. Names of firms and key personnel who participated in similar project (s) and are included in this SOQ, along with a clear description of the roles and responsibilities of each.
8. Provide a summary table to cross reference the project team (firms and key personnel) with participation in the reference projects.
I. Firm Specific Qualifications
The Contractor should identify the key strengths of the firm. Highlight capabilities and areas of specialization provided by the firm.
J. Project Approach
The Contractor should identify the process utilized on other continuing services contracts and the process envisioned for the services identified in this RFQ to ensure task authorizations meet expectations. This should include the process envisioned for interfacing with the City through the project manager. If sub-consultants are part of the team, describe the specific scope of work for each firm’s services and specifically in which types of projects the subconsultants will participate. Describe the firms approach to the management of subconsultants and subcontractors.
K. References
Provide a list of three (3) client contact persons for whom the Contractor has recently provided services similar in nature to the services identified in this RFQ.
L. Network Security and Records Retention
Provide a discussion on the firm’s approach to network security and records retention.
M. Technology Capabilities
Provide your technology capabilities, to include network operating systems, network security, software, your accounting system for tracking interest, electronic transmission of data, storage of payment information, and reporting. Include information related to the methods your firm would utilize to ensure data accuracy and integrity. Note: The City currently uses AutoCAD Civil 3D 2021, ESRI ArcMap 10.8, and ESRI ArcPro Version 3.0. All submitted electronic drawings will need to be compatible with these versions of CADD and GIS.
Rev: 08/09/23 Page 4(A) of 4(A)
N. Contractual Failures
Describe any alleged, significant prior or ongoing contract failures, licensing or permit violations, claims on bonds, any civil or criminal litigation or investigation pending (including wage theft complaints filed) which involves the firm or in which the firm has been judged guilty or liable.
O. Business Outreach Plan
Whether or not the Contractor or any of its subconsultants or subcontractors is a certified Minority Business Enterprise (MBE) as defined by the Florida Small and Minority Business Assistance Act, a Woman Owned Business Enterprise (WBE) a Disadvantaged Business Enterprise (DBE), and/or a Small Business Enterprise (SBE). If the Contractor and/or its subconsultants or subcontractors are a MBE, WBE, DBE, or SBE, provide the name of the firm and the certifying agency.
P. Licenses
Provide copies of Contractor's and individual’s current applicable Florida License.
| A. Submittal Requirements |
| I. Firm Specific Qualifications |
| J. Project Approach |
| K. References |
| L. Network Security and Records Retention |
| M. Technology Capabilities |
| N. Contractual Failures |
| O. Business Outreach Plan |
| P. Licenses |