This is an Agency Specific Requirements (ASR) document for a Federal Protective Service (FPS) facility lease in Grand Rapids, Michigan (reference 6MI0310), issued by GSA Public Buildings Service. The ASR outlines detailed space specifications and construction standards that are complementary to and may be more stringent than the base lease requirements.

The facility requires a total of 1,545 assignable square feet (ABOA SF) comprising three categories: office space (293 SF including six cubicles), support space (528 SF including break room, office support, huddle area, K9 bunker, and IT LAN closet), and mission space (724 SF including processing room, ammo/weapons/evidence safe, K9 storage, tactical area, and bulk storage). Construction specifications for open office areas, enclosed rooms, and break room/kitchenette areas detail requirements for flooring (carpet tile), walls, painting, doors, ceilings, lighting, electrical distribution, data/voice telecommunications, and window coverings. Additional specialized requirements include independent HVAC zoning with negative pressure capability for break rooms, specific electrical configurations for appliances, and adherence to FPS Real Property Management Manual standards and Region 5 Grand Rapids Construction Requirements. Security standards are governed by the FPS PACS SOW, IT standards by the Grand Rapids Area Command IT SOW and Gallagher PACS Equipment List, and furniture/fixtures/equipment standards by the TA-50 Brochure and R5 Grand Rapids FF&E specifications. The Lessor is responsible for adapting these requirements to the specific space.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AGENCY SPECIFIC REQUIREMENTS

PAGE 1 LESSOR: ______ GOVERNMENT: ________

6MI0310

Agency Specific Requirements

Federal Protective Service

The Agency Specific Requirements (ASRs) do not reduce the minimum requirements contained within the Lease. These ASRs provides specific agency requirements, which may be complementary, more specific, or more stringent than those of the Lease minimum requirements.

GSA Public Buildings Service

[Type text]

PAGE 2 LESSOR: ______ GOVERNMENT: ________

SECTION 1 ROOM SCHEDULE AND DETAILS

1.01 ROOM SCHEDULE

1.02 SPACE DETAILS

SECTION 2 DESIGN SCHEMATIC LAYOUT

2.01 DESIGN SCHEMATIC

2.02 ADJACENCY DIAGRAMS

SECTION 3 ADDITIONAL SPECIAL REQUIREMENTS AND DETAILS

3.01 ROOM LAYOUTS

3.02 ADDITIONAL CONSTRUCTION DETAILS

SECTION 4 GENERAL REQUIREMENTS

4.01 SECURITY

4.02 INFORMATION TECHNOLOGY

4.03 OTHER

SECTION 1 ROOM SCHEDULE AND DETAILS

1.01 ROOM SCHEDULE

Office Space

Space Type Quantity Space Allocation

(ABOA SF)

Total

Cubicle 6 36 216 Subtotal 216 Circulation Factor 36% 78

TOTAL 293

Support Space

Space Type Quantity Space Allocation

(ABOA SF)

Total

Break Room 1 72 72 Office Support Space 1 72 72 Huddle 1 72 72 K9 Bunker 1 72 72 IT LAN Closet 1 100 100 Subtotal 388 Circulation Factor 36% 140

TOTAL 528

Mission Space

Space Type Quantity Space Allocation

(ABOA SF)

Total

Processing Room 1 72 72 Ammo/Weapons/Evidence Safe 1 120 120 K9 Storage 1 120 120 Tactical 1 100 100 Bulk Storage 1 120 120 Subtotal 532 Circulation Factor 36% 192

TOTAL 724

Office + Support + Mission Space = 1,545 ABOA SF

PAGE 3 LESSOR: ______ GOVERNMENT: ________

1.02 SPACE DETAILS

Please refer to the Lease document for the constructions standards applicable to the interior tenant area build-out. These standards provide a general outline of the interior build-out requirements. For a complete list of requirements refer to the Lease document.

Open Office Area

· Flooring – Carpet tile per Lease paragraph FLOOR COVERINGS AND PERIMETERS

· Walls – Per Lease paragraph PARTITIONS: SUBDIVIDING with finishes according to Lease paragraph PAINTING - TI

· Doors – Per Lease paragraph DOORS: INTERIOR with hardware per Lease paragraph DOORS: HARDWARE

· Ceiling – Per Lease paragraph CEILINGS

· Lighting – Per Lease paragraph LIGHTING: INTERIOR AND PARKING – SHELL and

LIGHTING: INTERIOR AND PARKING- TI

· Electrical, Data, Voice – One duplex electrical receptacles and one combination data/voice jack per 80 ABOA SF on walls per Lease paragraph ELECTRICAL: DISTRIBUTION and TELECOMMUNICATIONS: DISTRIBUTION AND EQUIPMENT

· Window Coverings – Mini-blinds per Lease paragraph WINDOW COVERINGS for all windows

Enclosed Rooms

· Flooring – Carpet tile per Lease paragraph FLOOR COVERINGS AND PERIMETERS

· Walls – Per Lease paragraph PARTITIONS: SUBDIVIDING with finishes according to Lease paragraph PAINTING - TI

· Door – Per Lease paragraph DOORS: INTERIOR with hardware per Lease paragraph DOORS: HARDWARE

· Ceiling – Per Lease paragraph CEILINGS

· Lighting – Per Lease paragraph LIGHTING: INTERIOR AND PARKING

· Electrical, Data, Voice – Four duplex electrical receptacles and two combination data/voice jack on walls per Lease paragraph ELECTRICAL: DISTRIBUTION and TELECOMMUNICATIONS: DISTRIBUTION AND EQUIPMENT

· Window Coverings – Mini-blinds per Lease paragraph WINDOW COVERINGS for all windows

Break Room and Kitchenette Areas – Only applicable if room schedule calls for a break room or kitchenette area

· Flooring – Per FPS Construction requirements

· Walls – Per Lease paragraph PARTITIONS: SUBDIVIDING with finishes according to Lease paragraph PAINTING - TI

· Door – Per Lease paragraph DOORS: INTERIOR with hardware per Lease paragraph DOORS: HARDWARE

· Ceiling – Per Lease paragraph CEILINGS

· Lighting – Per Lease paragraph LIGHTING: INTERIOR AND PARKING

· Electrical, Data, Voice - Provide three duplex electrical receptacles and one wall combination data/voice jack. Provide two dedicated duplex electrical receptacles for refrigerators and two dedicated duplex electrical receptacles for vending machines. Provide two dedicated electrical receptacles for microwave ovens above the counter. Provide two additional duplex electrical receptacles above the counter (GFI as required by code).

· HVAC (Only if enclosed room) - Independent HVAC zone on thermostat in this room and provide means to ensure negative pressure for this room to avoid odors from escaping this room. Provide filters to remove odors from any air being mixed back into the supply air for the remainder of the building or exhaust directly to the outside.

· Window Coverings – Roller shades for all windows

PAGE 4 LESSOR: ______ GOVERNMENT: ________

· Millwork – Per FPS Construction requirements.

PAGE 5 LESSOR: ______ GOVERNMENT: ________

SECTION 2 DESIGN SCHEMATIC LAYOUT

2.01 DESIGN SCHEMATIC

General schematics of specific rooms identified in Section 1.01 can be found in Real Property Management Manual, Appendix C, attached hereto. The Lessor is responsible for using the room schedule in section 1.01 and this layout to adapt the Government’s requirements to the Space. Specific questions regarding the layout should be directed to the Lease Contracting Officer for resolution. The Government shall not be responsible for errors, omissions, or assumptions made by the Lessor in the adaption of the Government’s requirements to the Lessor’s Space.

PAGE 6 LESSOR: ______ GOVERNMENT: ________

SECTION 3 ADDITIONAL SPECIAL REQUIREMENTS AND DETAILS

3.01 ROOM LAYOUTS INTENTIONALLY DELETED

3.02 ADDITIONAL CONSTRUCTION DETAILS

See the below documents, attached herein. These standards may be more stringent than those listed in the Lease document. Where specified, these standards shall take precedence.

• FPS Real Property Management Manual

• Region 5 Grand Rapids Construction Requirements

PAGE 7 LESSOR: ______ GOVERNMENT: ________

SECTION 4 GENERAL REQUIREMENTS

4.01 SECURITY

The following security standards are listed in addition to those listed in the Lease document and the building specific security attachment. See the below document, attached herein

• FPS PACS SOW

4.02 INFORMATION TECHNOLOGY

4.03 The following IT standards are listed in addition to those listed in the Lease document. See the below documents, attached herein

• Grand Rapids Area Command IT SOW

• Gallagher PACS Equipment List

4.04 OTHER – FURNITURE, FIXTURES AND EQUIPMENT

The following FF&E standards are listed in addition to those listed in the Lease document. See the below documents, attached herein

• TA-50 Brochure DASCO

• R5 Grand Rapids FF&E

SECTION 1 room schedule and details
1.01 Room Schedule
1.02 space details
SECTION 2 design schematic layout
2.01 design schematic
SECTION 3 additional special requirements and details
3.01 room layouts INTENTIONALLY DELETED
3.02 additional construction details
SECTION 4 general requirements
4.01 security
4.02 information technology
4.03
4.04 Other – Furniture, Fixtures and Equipment