Exhibit_B_(2).docx

DOCX document 24 KB Posted

Attached to
Chemical Water Treatment Services for Glenarm Power Plant
Solicitation number
2025-RFP-0311
Issued by
Los Angeles County, Berkeley City, California

About this file

This is a cost calculation exhibit for circulating cooling water treatment services prepared for the City of Pasadena Water & Power Department's Glenarm Power Plant located in Pasadena, California. The exhibit establishes a standardized framework for bidders to calculate annual chemical treatment costs based on four primary chemical categories: scale inhibitor, corrosion inhibitor, oxidizing biocide, and non-oxidizing biocide. Bidders are required to specify their recommended number of concentrations (minimum of two, maximum of one, with an average used for calculations), identify the generic type and product name/number for each chemical, provide the required dosage rates in parts per million or pounds per year, and submit unit costs per pound of chemical. The form requires bidders to calculate annual costs for each chemical category, with oxidizing biocide dosage set at 150 pounds per year and non-oxidizing biocide applications occurring 50 times annually during summer months.

The pricing structure incorporates blowdown costs associated with scale and corrosion inhibitors, calculated per million pounds of blowdown water. Bidders must project total annual blowdown volumes and calculate the combined annual chemical cost by multiplying the blowdown rate by the total cost per million pounds of blowdown. The final deliverable is a total circulating cooling water treatment annual cost, calculated by summing annual expenses for chemical blowdown, oxidizing biocide, and non-oxidizing biocide. The exhibit also requires bidders to specify complete product specifications for each of the four chemical categories, providing transparent pricing visibility for the Water & Power Department's evaluation of qualified chemical consultant proposals.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXHIBIT J

Page 1 of 3
EXHIBIT BPage 2 of 3

GT-3, GT-4 & GT-5 CIRCULATING COOLING WATER TREATMENT COST CALCULATION

RECOMMENDED NUMBER OF CONCENTRATIONS

Maximum Number of Concentrations

--
(1)

Minimum Number of Concentrations

--
(2)

Average Number of Concentrations (Note 1)

--
(3)

Note 1: Calculations for chemical consumption shall be based on your recommended average number of concentrations.

SCALE INHIBITOR

Name/No.

Generic Type

PPM of Chemical Required in the Condenser Water

Lb./1,000,000 Pounds of water
(4)
Cost per Pound of Chemical
$
/lb.
(5)

CORROSION INHIBITOR

Name/No.

Generic Type

PPM of Chemical Required in the Condenser Water

Lb./1,000,000 Pounds of water
(6)
Cost per Pound of Chemical
$
/lb.
(7)

OXIDIZING BIOCIDE

Name/No.

Generic Type

Recommended Dosage Rate
150
Lb. oxidizing biocide/yr.
(8)
Cost per Pound of Chemical
$
/lb.
(9)

NON-OXIDIZING BIOCIDE

Name/No.

Generic Type

Recommended Dosage Rate

Lb./1,000,000 Pounds of water
(10)

Number of Applications per Year (Mainly During Summer Time)

/yr.

(11)

Cost per Pound of Chemical
$
/lb.
(12)

ANNUAL COST FOR CHEMICALS

Scale Inhibitor Cost (4) x (5) =

/1,000,000 Pounds of water
(13)

Corrosion Inhibitor Cost (6) x (7) =

/1,000,000 Pounds of water
(14)

Oxidizing Biocide Cost (8) x (9) =

/yr.

(15)

Non-Oxidizing Biocide Cost Million Pounds of Water, see note 2, x (10) x (11) x (12) =

(16)

Note 2: For annual cost calculation for chemicals, use 0.2 for number of Million Pounds of Water for the above two equations

COST OF BLOWDOWN

Scale Inhibitor Cost per Million Pounds of Blowdown
$
From (13)
--
Corrosion Inhibitor Cost per Million Pounds of Blowdown
$
From (14)
--

Total Cost for Scale & Corrosion Inhibitors

(13) + (14) =

$
/1,000,000 Pounds of Blowdown
(17)
Total Annual Blowdown
$
Million Pounds of Blowdown
(18)
Annual Chemical Cost by Blowdown (17) x (18)
$
/yr.
(19)

CIRCULATING COOLING WATER TREATMENT ANNUAL COSTS

Annual Chemical Cost by Blowdown
$
From (19)
--
Annual Oxidizing Biocide Cost
$
From (15)
--
Annual Non-Oxidizing Biocide Cost
$
From (16)
--

Total Circulating Cooling Water Treatment Annual Cost (19) + (15) + (16) =

(20)

CIRCULATING COOLING WATER SYSTEM PRODUCT SPECIFICATIONS

SCALE INHIBITOR:

CORROSION INHIBITOR:

OXIDIZING BIOCIDE:

NON-OXIDIZING BIOCIDE: