Text version
US Consulat Anlage ( Servicevertrag) Wartungsplan NEA
Monthly test run, 2 hours respectively W1 x
Annual load test run including provision of load bank, assembling, dismantling and cable connection x
G055.050.01 Valve control Check valve clearance W3 x
G083.051.03 Fuel twin filter Replace spin-on filter W3 x
G083.101.15 Clean fuel pre-filter W3 x
G180.000.04 Motor oil Take used oil sample and inspect W3 x
G180.000.05 Change motor oil after 2 years respectively, at the latest after 500 operating hours for oil category 2
W3 x after 1000 operating hours for oil category 3 W3 x
G183.052.03 Replace motor oil filter W3 x together with motor oil change W3 x
G202.000.05 Take motor coolant sample, and inspect W3 x
Replace motor coolant, refer to MTU fuel specifications W3 x
G202.051.01 G202.051.01 Motor coolant pump Check relief opening for consistency
W3 x
G203.000.07 Charge-air coolant Take sample, and inspect W3 x
Change coolant, refer to MTU fuel specifications W3 x
G203.051.01 Charge-air coolant pump Check relief opening for consistency
W3 x
G205.051.01 Motor coolant heat exchanger W3 x
(High temperature cycle) W3 x
Check cooler elements for external fouling W3 x G205.051.03 Motor coolant heat exchanger W3 x
(low temperature cycle) W3 x
Check cooler elements for external fouling W3 x
Electrical inspections Drive motor and tank system
Check deactivation criteria x Check reports and messages x Check controller behavior x Check starter and generator x Check functionality of stopping solenoid x Check fuel pump between tank and aggregate x Check fuel filling pump x Check pre-lubrication, check pre-lubrication and break periods x
Exhaust system Visual inspection x
Cooling system Check thermostat x annuallyItem numbers Maintenance work Maintenance level monthly
Seite 1 von 3 7/15/2022
Check ventilation of engine room, x Check supply and exhaust air louvers for functionality and smooth running x
Check cooling water circulation pump x Check cooling water preheating, adjust if required x Check cooling water level in compensation tank x Check limit value transmitter and filling level monitor x
Measuring devices Check temperature control switch, remote thermometer, x oil pressure gauge and oil pressure sensor x Check display/measuring instruments in the switch cabinet x
Starter battery and charger Check battery charging and density and re-charge if required x
Check connections, clean and grease if required x Check charging state of individual cells x Check all functions of battery charger x Check battery undervoltage and overvoltage detector, adjust if required x
Control of emergency power system Functional check of operating modes x Automatic x Test x Manual with/without load x Check emergency shut-off function x Synchronization: Check automatic/manual x Check-resynchronization x Check network disconnection/protection x Check network/generator voltage monitor, adjust if required x
Execute power failure test x Check start delay time, adjust if required. x Check takeover time of emergency power system, adjust if required x
Check reset delay after power recovery x Execute a test start. If required, connect consumers via push button control x
Start via starter switch x Check horn with disconnection x Check signal lamps x Simulate or stimulate all error messages x Check switch contacts for loss of contact material x Check connections and ground connections x Check remote signaling x Clean active and inactive parts x
Generator Check constant voltage unit, check regulation x Check connections of power cables with torque x Re-lubricate roller bearings in accordance with lubrication regulations x
Check coil for dust deposits and remove dust x by blowing out x Check connections at controller x
General Check the aggregate room x
Seite 2 von 3 7/15/2022
Check groundings x Check labelings and room markings x Check that circuit diagrams are complete x Check completeness of safety resources (fire extinguishers, emergency lighting, flashing light) x
Complete inspection records x
The scope of work specified in the maintenance plan applies for various network systems and need not comply completely with the machine to be serviced in this specific case.