EXHIBIT 6 - Standard Drawing - RD815.pdf

PDF 346 KB Posted

Attached to
ESB US101 Davis Slough Maintenance Facility Fence Upgrade
Solicitation number
S-73000-00017821
Issued by
Coos County, Oregon

About this file

EXHIBIT 6 - Standard Drawing - RD815

This standard drawing document, prepared for the Oregon Department of Transportation (ODOT), provides technical specifications and construction details for the ESB US101 Davis Slough Maintenance Facility Fence Upgrade project located at US 101, MP 243.2 in Coos County, Oregon. The drawing establishes the standard specifications for the installation of approximately 450 linear feet of agency-supplied chain-link security fencing to replace existing T-post fencing. The document outlines the precise construction methodology, material requirements, and dimensional specifications necessary for contractors to properly execute the fence removal and replacement work, ensuring consistency with Oregon DOT standards and project requirements.

The standard drawing serves as the authoritative reference document for all bidders and contractors undertaking this project, detailing the technical requirements, construction sequencing, and quality standards that must be adhered to during both the removal of the existing fence infrastructure and the installation of the new security fencing system. This drawing is integral to the bid package and contract documentation, as it eliminates ambiguity regarding construction expectations and provides the technical framework within which all work must be performed.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RD815

CHAIN LINK FENCE

R D

.d g n

13-JAN-2020N/A

J U

L

1 1

S T

E E

L m in

" 4

1 1 1 for intermediate end post

Symmetrical about post

D D F

(in) nom.

(in) min.

(in) min.

CL-4

CL-5

include slat wind loading.

NOTE: For CL-6, CL-6R, CL-8, CL-8R, CL-10 & CL-10R, the hardware is minimum and does not bar

Stretcher post or corner

End, gate

Ground line footing

Concrete

Line post

" dia.8

Truss rod

Brace rail

(alternate position)

Brace rail

7 gauge

Tension wire

9" dia. min.

12" dia. min.

6" gate post

20" dia. min. for footing

Concrete 9" dia. min.

m in

10'-0" max. 10'-0" max.

600'-0" max. run f a b r ic m in

10'-0" max.

11 gauge mesh fabric 2"

Chain link

Line post

7 gauge

Tension wire

Ground line footing

Concrete

12" dia. min.

See general note 8

End and Corner Posts.

and install lower brace rail in alternate position at

For runs of fence of 20' or less, omit truss rod

Brace rail

" dia.8

Truss rod

Intermediate end post

Line post

Brace rail

" dia.8

Truss rod

Stretcher bar

9" dia. min.

m in m in

10'-0" max.

10'-0" max.

600'-0" max. run 10'-0" max.

m in m in f a b r ic

See general note 8 end post intermediate corner or

End, gate, Footing

Concrete

Bracing symmetrical intermediate end post about post for

12" dia. min.

6" gate post

20" dia. min. for

(See gen. note 2)

" dia.8

Truss rod

Ground line

Brace rail

Top rail

Stretcher bar

Line post

7 gauge wire

Tension footing

Concrete

9" dia. min.

omit truss rod at end and corner posts.

For runs of fence of 20' or less, Top rail

Line post

11 gauge

2" mesh fabric

Chain link line

Ground

9" dia. min.

m in post or corner

End, gate bar

Stretcher

Brace rail footing

Concrete

9" dia. min.

Line post note 2)

(See gen.

" dia.8

Truss rod

7 gauge

Tension wire footing

Concrete

D D

10'-0" max. 10'-0" max.

600'-0" max. run

6" gate post.

20" dia. min. for

12" dia. min.

Line Post

11 gauge mesh fabric 2"

Chain link

9" dia. min.

"2

" dia.8

Truss rod

D

F a b r ic h e ig h t

F

7 gauge

Tension wire 10'-0" max.

D

Stretcher bar Brace rail

Ground line footing

Concrete

12" dia. min.

See general note 8

9" dia. min.

bar

Stretcher

" dia.8

Truss rod

Brace rail

Intermediate end post

Line post

10'-0" max.

D 4 end post intermediate corner or

End, gate, Top rail

Stretcher bar

Ground line 7 gauge wire

Tension

Line post footing

Concrete

6" gate post

20" dia. min. for

12" dia. min.

9" dia. min. 9" dia. min.

footing

Concrete

11 gauge

2" mesh fabric

Chain link

Line post

Top rail10'-0" max.

600'-0" max. run

10'-0" max.

DD D

F a b r ic h e ig h t

F at end and corner posts.

For runs of fence of 20' or less, omit truss rod

See general note 8

(in) min.

D

(in) min.

D

(in) nom.

F

CL-4R

CL-5R

36 36

24 48

TYPE

in

F e n c e I n d u s tr y in

N o m

D ia in

F e n c e I n d u s tr y in

N o m

D ia in

S iz e l b f t

W t.

in

F e n c e I n d u s tr y in

N o m

D ia

GATE

SINGLE

GATE

DOUBLE

CL-5 & CL-5R

CL-4 & CL-4R

S T

E E

L

TYPE

CL-6 & CL-6R 8

1 4

1 8

2 2 x4

4.10 8

2 2

22.72 x8

(ft)

GATE OPENING

TUBULARH-SECTIONTUBULARTUBULAR

TOP RAILS

AND

BRACE

LINE POSTS

END POST

INTERMEDIATE

END, CORNER &

POSTS

GATE

TUBULAR

in

N o m

D ia in

F e n c e I n d u s tr y

2Up thru 12Up thru 6

7 thru 13

14 thru 18 27 thru 36

13 thru 26 4

Gate post

" dia.8

Truss rod line

Ground post

Gate

" nom. pipe size2

Gate frame

Gate opening

(As shown on plans)

Gate opening

(As shown on plans )

11 gauge

2" mesh

Chain link fabric

Gate post

Stretcher bar

See general note 8

10. Add fence grounding as required.

9. See project plans for details not shown.

" diamond mesh.2

" by 52 gauge wire woven in 3

8. Chain link fabric for the fence to be installed with pickets shall be 9

7. All chain link fabric top and bottom selvage shall be knuckled finish.

6. All concrete shall be commercial grade concrete.

See ODOT's QPL for acceptable alternates.

AASHTO M181 are acceptable alternates.

5. Posts and rails with sections not shown that meet the requirements of

4. For cross sectional dimensions of members, see Table 1.

to be as indicated for a single gate installation of the wider gate width.

double gate installation with unequal width gates, size of both posts

3. Gate posts on each side of a gate opening to be the same size. At a

2. Fittings shown are illustrative of use and not specific as to design.

1. Do not use top rail where fence can be struck by an errant vehicle.

GENERAL NOTES FOR ALL DETAILS ON THIS SHEET:

GATES

TYPES CL-4R & CL-5R

TYPE CL-6

TYPES CL-4 & CL-5

TYPE CL-6R

DOUBLESINGLE

M E M B E R

TYPE

T A B L E 1 the current Oregon Standard Specifications.

All materials shall be in accordance with

DATE REVISION DESCRIPTION

OREGON STANDARD DRAWINGS

DATE

SDR

BOOK NO.

CALC.

Effective Date: December 1, 2025 - May 31, 2026

Professional Engineer.

first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with

Standard Drawing, while

The selection and use of this

HWYE30Y

Line

HWYE30Y

Line

HWYE30Y

Line

HWYE30Y

Line

File details come from the government source that posted it. Updated .