Exhibit 3 UPDATED.pdf
PDF 428 KB Posted
- Attached to
- D7 Fire Panel - Critical Infrastructure
- Solicitation number
- 24-494DOT-FINAD-B-41692
- Issued by
- Edgar County, Illinois
About this file
This document is an exhibit listing the equipment and quantities required for a fire alarm system upgrade project for critical infrastructure facilities in Illinois. The project covers facilities in Effingham County and includes the replacement of a main fire alarm control panel, cellular communicator, remote annunciators, smoke and heat detectors, pull stations, modules, and audible/visual devices. The document provides estimates for the quantity of each device needed, along with details on the existing wiring infrastructure and power requirements. The project is a state and local contract opportunity identified as "D7 Fire Panel - Critical Infrastructure" for the State of Illinois.
The pricing and contractual terms are not explicitly stated in this document. However, the exhibit suggests this is part of a larger procurement process, and additional information such as funding sources, set-asides, and incumbent providers may be available in the full solicitation package.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Device List
Estimated number of devices based on previous system and may not be a complete list.
**If not listed below, must include necessary devices necessary to have a fully functioning system**
Description Quantity Main Fire Panel – Addressable Fire Releasing 1 Cellular Communicator – To Monitoring Company 1 LCD Remote Annunciator - Red Enclosure 3 Digital Alarm Communicator Technology (DACT) 1 Batteries for Battery Backup for Fire Panel – Assumed 12V 8A 8 Network and Power Expander Panel (Repeater / Extender) 3 Photoelectric Smoke Detector – Photo Detector 155 6” Detector Base 165
Heat Detector 10 Duct Detector w/ Relay 12 Sampling Tube for Addressable Duct Detector 12 Addressable Pull Station 17 Single Input Module 12 Relay Module 6 Selectable Horn/Strobe – Red 75 Selectable Strobe – Red 30
Circuits:
Voltage: 120V 20A
Class: Class 4 Style Y
Currently Installed Wiring:
Device Wire: 14/2 Solid Wire – Red – Fire/Life Safety Control Cable
Network/Phone: CAT5e Cabling
Power/Network Extender Panels:
Extender Panel #1 – Main Building by Main Panel = 4 NAC Branches
Extender Panel #2 – Annex Building = 3 NAC Branches
Extender Panel #3 – OPs/Survey Building = 4 NAC Branches
File details come from the government source that posted it. Updated .