Exhibit 3 - Construction Drawings 12.07.2023.pdf

PDF 4 MB Posted

Attached to
East Leroy Elementary School - Mechanical Improvements
Solicitation number
RFP - ATH - 240000000560
Issued by
Calhoun County, East Jordan City, Michigan

About this file

This document contains construction drawings and plans for the mechanical upgrades at East Leroy Elementary School, located in East Leroy, Michigan. The project is being undertaken by Athens Area Schools, a school district in Calhoun County, Michigan.

The mechanical upgrades include replacing HVAC systems, boilers, piping, and other mechanical equipment throughout the school. The project involves work in three separate building units (Units A, B, and C), with a total finished project area of 33,774 square feet. The project must adhere to various building codes and standards. Bidders will need to review the detailed plans, specifications, and project details provided in the attachments. No specific bid due date or award date is mentioned, but the project is currently in the design and planning phase.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

DESIGN TEAM

ARCHITECT/ENGINEER

EAST LEROY ELEMENTARY MECHANICAL

UPGRADES

ATHENS AREA SCHOOLS

East Leroy, Michigan

CONSTRUCTION DOCUMENTS

C O

V E

R S

H E

E T

.1

G

E A

S T

L E

R O

Y E

L E

M E

N T

A R

Y M

E C

H A

N

IC

A L

U P

G R

A D

E S

E a s t L e ro y M ic h ig a n

A T

H E

N S

A R

E A

S C

H O

O L S

D E

C E

M B

E R

DRAWING INDEX

EAST LEROY ELEMENTARY SCHOOL

4320 K DRIVE SOUTH

EAST LEROY, MI 49051

242 E. KALAMAZOO AVE, SUITE 100

KALAMAZOO, MICHIGAN 49007

PHONE: 269.343.6133

FAX: 269.343.6633

CONSTRUCTION MANAGER

120 EAST PRAIRIE STREET, SUITE C

VICKSBURG, MI 49097

PHONE: 269.349.6133

FAX: 269.349.5936

BUILDING: 2015 MICHIGAN BUILDING CODE AND 2012 NFPA 101 LIFE SAFETY CODE

ENERGY: 2015 MICHIGAN ENERGY CODE

PLUMBING: 2018 MICHIGAN PLUMBING CODE

MECHANICAL: 2015 MICHIGAN MECHANICAL CODE

FUEL GAS: (IFGC) 2015 INTERNATIONAL FUEL GAS CODE

ELECTRICAL: 2017 NATIONAL ELECTRICAL CODE WITH MICHIGAN AMENDMENTS

BARRIER-FREE: 2015 MICHIGAN BUILDING CODE AND 2009 ICC & C A117.1

USE GROUP: E

CONSTRUCTION TYPE: IIB

AUTOMATIC SPRINKLERS: NONE

PROJECT AREA

TOTAL FINISHED PROJECT: 33,774 SQ. FT.

REFERENCED CODES

SITE ADDRESS

GENERAL

G 001 COVER SHEET

G 101 FIRST FLOOR CODE COMPLIANCE PLAN

ARCHITECTURAL GENERAL

AG 001 GENERAL ARCHITECTURAL NOTES, INTERIOR PARTITION TYPES AND

DEVICE ALIGNMENT GUIDELINES

ARCHITECTURAL DEMOLITION

AD 101A FIRST FLOOR DEMOLITION PLAN - UNIT A

AD 101B FIRST FLOOR DEMOLITION PLAN - UNIT B

AD 101C FIRST FLOOR DEMOLITION PLAN - UNIT C

AD 102 OVERALL ROOF DEMOLITION PLAN

ARCHITECTURAL

A 101A FIRST FLOOR PLAN - UNIT A

A 101B FIRST FLOOR PLAN - UNIT B

A 101C FIRST FLOOR PLAN - UNIT C

A 102 OVERALL ROOF PLAN

A 201A FIRST FLOOR REFLECTED CEILING PLAN - UNIT A

A 201B FIRST FLOOR REFLECTED CEILING PLAN - UNIT B

A 201C FIRST FLOOR REFLECTED CEILING PLAN - UNIT C

MECHANICAL & PLUMBING GENERAL

MG 001 MECHANICAL & PLUMBING GENERAL NOTES, ABBREVIATIONS, AND

SYMBOLS

MECHANICAL DEMOLITION

MD 101A FIRST FLOOR MECHANICAL DEMOLITION PLAN - UNIT A

MD 101B/C FIRST FLOOR MECHANICAL DEMOLITION PLAN - UNIT B & C

MECHANICAL

M 101A FIRST FLOOR MECHANICAL PLAN - UNIT A

M 101B/C FIRST FLOOR MECHANICAL PLAN - UNIT B & C

M 401 HVAC PIPING SCHEMATICS

M 501 MECHANICAL SCHEDULES AND DETAILS

M 502 MECHANICAL SCHEDULES AND DETAILS

M 601 MECHANICAL CONTROLS

M 602 MECHANICAL CONTROLS

ELECTRICAL - GENERAL

EG 001 ELECTRICAL SYMBOLS AND GENERAL NOTES

ELECTRICAL DEMOLITION

ED 101A FIRST FLOOR ELECTRICAL DEMOLITION PLAN - UNIT A

ED 101B FIRST FLOOR ELECTRICAL DEMOLITION PLAN - UNIT B

ED 101C FIRST FLOOR ELECTRICAL DEMOLITION PLAN - UNIT C

ELECTRICAL

E 101A FIRST FLOOR POWER PLAN - UNIT A

E 101B FIRST FLOOR POWER PLAN - UNIT B

E 101C FIRST FLOOR POWER PLAN - UNIT C

E 201A FIRST FLOOR LIGHTING PLAN - UNIT A

E 401 ELECTRICAL ONE-LINE DIAGRAM

E 411 ELECTRICAL DETAILS AND CONNECTION SCHEDULES

E 501 ELECTRICAL PANEL LOAD SCHEDULES

ISSUED FOR DATE

DN

EQ

EQ

EQ

EQ

EQ EQ

EQ

EQ

EQ EQ

EQ EQ EQ EQ EQ EQ

EQEQEQ

EQ

EQ

EQ

EQ EQ EQ EQ

EQ EQ

EQ EQ

EQ

EQ

EQ EQ EQEQ

J

J

EQ

EQ

WAPWAP

WAP

WAP WAPWAP

1. ALL PENETRATIONS THROUGH A FIRE OR SMOKE RATED PARTITION SHOULD BE

SEALED WITH AN APPROVED U.L. RATED PRODUCT.

2. THE TOPS OF ALL FIRE RATED PARTITIONS SHALL BE SEALED TO THE

CONTINUOUS STRUCTURE ABOVE WITH A U.L. RATED SYSTEM OR ASSEMBLY.

3. WOOD BLOCKING IN FIRE-RATED PARTITIONS SHALL BE NON-COMBUSTIBLE

TREATED WOOD.

4. REFER TO SPECIFICATION U.L. RATING INFORMATION.

5. FIRE-RATED WALLS ENDING INTO AN ACOUSTICAL DECK MUST HAVE THE FLUTES

FILLED, REFER TO 'TOP OF WALL DETAIL AT ACOUSTIC DECK' SHOWN ON THIS

SHEET.

• FOR MASONRY WALLS THE MASON SHALL FILL VOIDS AND FIRE SPRAY WITH UL LISTED

MATERIAL.

• FOR STUD WALLS USE FIRE SAFING AND FIRE CAULK.

CODE COMPLIANCE KEY

EGRESS SYMBOLS

EGRESS EXIT NUMBER FROM ROOM OR SPACE

MAXIMUM NUMBER OF OCCUPANTS PERMITTED

BY EGRESS WIDTH

ROOM OR SPACE EGRESS IS FROM

TRAVEL DISTANCE : 100'-0"

PERMITTED TRAVEL DISTANCE - 200'-0"

EXISTING TRAVEL DISTANCE

TO EGRESS DOOR

PERMITTED MAXIMUM TRAVEL

DISTANCE PER CONDITION

DIRECTION OF EGRESS

FIRE SAFETY SYMBOLS

FIRE-RATING KEY

XFE

XFEC

FE

FEC

EXISTING FIRE EXTINGUISHER

EXISTING FIRE EXTINGUISHER CABINET

FIRE EXTINGUISHER

FIRE EXTINGUISHER CABINET

AED

AUTOMATED EXTERNAL DEFIBRILLATOR (AED)

RECESSED CABINET

DESIGNATION RATING PRIORITY

3 HOUR 1

2 HOUR 2

1 HOUR 3

SMOKE RESISTANT 4

COORDINATE ALL REQUIRED DAMPERS WITH MECHANICAL.

EGRESS ROOM

CORRIDOR

VESTIBULE

CLASSROOM

CLASSROOM

CLASSROOM

CUSTODIAN

TOILET

STAFF

CONFERENCE

LIBRARY

DATA

RELATED

ACTIVITIES

COUNSELOR

COMPUTER

LAB

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

HEALTH

TOILET

OFFICE

VAULT

OFFICE

CLASSROOM

CLASSROOM

CLASSROOM

LOBBY

MEN'S

TOILET

WOMEN'S

TOILET

BOILER ROOM

KITCHEN

TOILET

KITCHEN

STORAGE

STORAGE

MULTI-PURPOSE

ROOM

CLASSROOM

TOILET

TOILET

CLASSROOM

CLASSROOM

152CLASSROOM

CLASSROOM

CONFERENCE

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

F

IR

S T

F L O

O R

C O

D E

C O

M P

L

IA

N C

E P

L A

N

.1

G

E A

S T

L E

R O

Y E

L E

M E

N T

A R

Y M

E C

H A

N

IC

A L

U P

G R

A D

E S

E a s t L e ro y M ic h ig a n

A T

H E

N S

A R

E A

S C

H O

O L S

D E

C E

M B

E R

THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN

COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,

IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN

AN ACCURATE DRAWING

3/32" = 1'-0"

FIRST FLOOR CODE COMPLIANCE PLAN

THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN

COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,

IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN

AN ACCURATE DRAWING

EAST LEROY ELEMENTARY

UNIT

A

UNIT B UNIT C

KEY PLAN

SCALE: NO SCALE

HEAD

PLAN

SILL

STRUCTURE /

DECK ABOVE

DEFLECTION TRACK

SEALANT

SOUND BATTS IN

ALL WALLS -

UNLESS NOTED

OTHERWISE

FLOOR CONSTRUCTION

METAL STUDS @ 16" O.C. WITH 5/8"

GYPSUM BOARD BOTH SIDES;

(1 HOUR FIRE) U.L. ASSEMBLY U465

WHERE NOTED ON PLANS

METAL STUD WALL

HEAD

PLAN

SILL

STRUCTURE /

DECK ABOVE

DEFLECTION TRACK

SEALANT

SOUND BATTS (AT CHASE

WALLS ONLY) - UNLESS

NOTED OTHERWISE

FLOOR CONSTRUCTION

METAL STUDS @ 16" O.C. WITH 5/8"

GYPSUM BOARD ON ROOM SIDE - BRACE

WALL @ 4'-0" O.C. MAXIMUM.

METAL STUD CHASE WALL

OR FURRING

HEAD

PLAN

SILL

STRUCTURE /

DECK ABOVE

DEFLECTION TRACK

SEALANT

SOUND BATTS IN

ALL WALLS -

UNLESS NOTED

OTHERWISE

FLOOR CONSTRUCTION

METAL STUDS @ 16" O.C. WITH

5/8" TYPE "X" GYPSUM BOARD BOTH

SIDES TO DECK

STRUCTURAL METAL STUD WALL

HEAD

PLAN

SILL

STRUCTURE /

DECK ABOVE

DEFLECTION TRACK

SEALANT

FLOOR CONSTRUCTION

METAL CH STUDS @ 16" O.C. WITH 5/8"

TYPE "X" GYPSUM BOARD ON ROOM

SIDE AND 1" TYPE "X" GYPSUM BOARD

PANEL ON CHASE SIDE

HEAD

PLAN

SILL

STRUCTURE /

DECK ABOVE

DEFLECTION TRACK

SEALANT

SOUND BATTS IN

ALL WALLS -

UNLESS NOTED

OTHERWISE

FLOOR CONSTRUCTION

METAL STUDS @ 16" O.C. WITH (2)

LAYERS 5/8" TYPE "X" GYPSUM

BOARD BOTH SIDES

HEAD

PLAN

SILL

STRUCTURE /

DECK ABOVE

DEFLECTION TRACK

SEALANT

SOUND BATTS IN ALL

WALLS - UNLESS

NOTED OTHERWISE -

WEAVE IN-BETWEEN

STUDS

FLOOR CONSTRUCTION

6" TOP AND BOTTOM TRACK WITH 3 5/8"

METAL STUD FRAMING @ 16" O.C.

(OFFSET) WITH 5/8" GYPSUM BOARD BOTH

SIDES

HEAD

PLAN

SILL

STRUCTURE /

DECK ABOVE

BOND BEAM

SEALANT

FLOOR CONSTRUCTION

4" CONCRETE MASONRY UNITS

CMU WALL (1 AND 2 HOUR FIRE)

U.L. ASSEMBLY - U905

HEAD

PLAN

SILL

CMU WALL WITH FURRING CMU WALL WITH FURRING BOTH SIDES

C H A S E S

ID

E

R O

O M

S

ID

E

METAL STUD CHASE WALL (1 HOUR FIRE)

U.L. ASSEMBLY U415

METAL STUD WALL (2 HOUR FIRE)

U.L. ASSEMBLY U425

METAL STUD SOUND WALL

6" CONCRETE MASONRY UNITS

8" CONCRETE MASONRY UNITS

10" CONCRETE MASONRY UNITS

STRUCTURE /

DECK ABOVE

BOND BEAM

FLOOR CONSTRUCTION

STRUCTURE /

DECK ABOVE

BOND BEAM

FLOOR CONSTRUCTION

HEAD

PLAN

SILL

4" CONCRETE MASONRY UNITS WITH METAL

FURRING AND 5/8" GYPSUM BOARD

6" CONCRETE MASONRY UNITS METAL FURRING

AND 5/8" GYPSUM BOARD

8" CONCRETE MASONRY UNITS WITH METAL

FURRING AND 5/8" GYPSUM BOARD

10" CONCRETE MASONRY UNITS WITH METAL

FURRING AND 5/8" GYPSUM BOARD

4" CONCRETE MASONRY UNITS WITH METAL FURRING

AND 5/8" GYPSUM BOARD - BOTH SIDES

12" CONCRETE MASONRY UNITS 12" CONCRETE MASONRY UNITS WITH METAL

FURRING AND 5/8" GYPSUM BOARD

1X 2X 4X 5X

HEAD

PLAN

SILL

STRUCTURE /

DECK ABOVE

DEFLECTION TRACK

SEALANT

FLOOR CONSTRUCTION

METAL CH STUDS @ 16" O.C. WITH (2)

LAYERS 5/8" TYPE "X" GYPSUM BOARD

ON ROOM SIDE AND 1" TYPE "X"

GYPSUM BOARD PANEL ON CHASE SIDE

METAL STUD CHASE WALL (2 HOUR FIRE)

U.L. ASSEMBLY U438

6X 7X 8

6" CONCRETE MASONRY UNITS WITH METAL FURRING

AND 5/8" GYPSUM BOARD - BOTH SIDES

8" CONCRETE MASONRY UNITS WITH METAL FURRING

AND 5/8" GYPSUM BOARD - BOTH SIDES

10" CONCRETE MASONRY UNITS WITH METAL

FURRING AND 5/8" GYPSUM BOARD - BOTH SIDES

12" CONCRETE MASONRY UNITS WITH METAL

FURRING AND 5/8" GYPSUM BOARD - BOTH SIDES

9X

10X

11X

12X

13X

9XX

10XX

11XX

12XX

13XX

SEALANT SEALANT

METAL STUDS @ 16" O.C. WITH

1/2" RATED PLYWOOD ONE SIDE

AND 5/8" GYPSUM BOARD ON

BOTH SIDES.

3X

HEAD

PLAN

SILL

STRUCTURE /

DECK ABOVE

DEFLECTION TRACK

SEALANT

1/2" RATED

PLYWOOD

FLOOR CONSTRUCTION

METAL STUD WALL

WITH PLYWOOD BACKING

SOUND BATTS IN

ALL WALLS -

UNLESS NOTED

OTHERWISE

SOUND BATTS IN

ALL WALLS -

UNLESS NOTED

OTHERWISE

HEAD

PLAN

SILL

STRUCTURE /

DECK ABOVE

SEALANT

SOUND BATTS IN

ALL WALLS -

UNLESS NOTED

OTHERWISE

FLOOR CONSTRUCTION

WOOD STUDS @ 16" O.C. WITH 5/8"

GYPSUM BOARD BOTH SIDES;

(1 HOUR FIRE) U.L. ASSEMBLY U305

WHERE NOTED ON PLANS

WOOD STUD WALL

HEAD

PLAN

SILL

STRUCTURE /

DECK ABOVE

SEALANT

SOUND BATTS IN ALL

WALLS - UNLESS

NOTED OTHERWISE

FLOOR CONSTRUCTION

WOOD STUDS @ 16" O.C. WITH 5/8"

GYPSUM BOARD ON ROOM SIDE -

BRACE WALL @ 4'-0" O.C. MAXIMUM.

WOOD STUD CHASE WALL

C H A S E S

ID

E

R O

O M

S

ID

E

14X 15X

HEAD

PLAN

SILL

STRUCTURE /

DECK ABOVE

SEALANT

SOUND BATTS IN

ALL WALLS -

UNLESS NOTED

OTHERWISE

FLOOR CONSTRUCTION

WOOD STUDS @ 16" O.C. WITH (2)

LAYERS 5/8" TYPE "X" GYPSUM

BOARD BOTH SIDES

WOOD STUD WALL (2 HOUR FIRE)

U.L. ASSEMBLY U301

16X

SOUND BATTS IN

ALL WALLS -

UNLESS NOTED

OTHERWISE

INTERSECTION OF NON-RATED AT

1 HOUR RATED PARTITION

INTERSECTION OF NON-RATED AT 2 HOUR

RATED PARTITION - U.L. ASSEMBLY U425

1 HOUR RATED

PARTITION - REFER

TO PLAN

METAL STUD FRAMING

NON-RATED PARTITION - REFER TO PLAN

2 HOUR RATED

PARTITION -

REFER TO PLAN

METAL STUD FRAMING

NON-RATED PARTITION - REFER TO PLAN

INTERSECTION OF NON-RATED AT 2 HOUR

RATED PARTITION - U.L. ASSEMBLY U438

2 HOUR RATED

PARTITION -

REFER TO PLAN

CH STUD FRAMING

NON-RATED PARTITION - REFER TO PLAN

INTERSECTION OF

CONCRETE/MASONRY AT 1 HOUR

RATED PARTITION

CONCRETE OR MASONRY

WALL - REFER TO PLAN

1 HOUR RATED PARTITION -

REFER TO PLAN

METAL FURRING

GYPSUM BOARD CONTROL

JOINT NON-RATED PARTITION

• 1/2" MAXIMUM GAP FOR CONTROL JOINT

• 30'-0" MAX. BETWEEN CONTROL JOINTS

• REFER TO PARTITION TYPES FOR COMPLETE

DESCRIPTION OF COMPONENT PARTS

GYPSUM BOARD

METAL STUD FRAMING

BACKER

ROD AND

SEALANT

CONTROL JOINT

GYPSUM BOARD CONTROL

JOINT 1 HOUR RATED

PARTITION

• 1/2" MAXIMUM GAP FOR CONTROL JOINT

• 30'-0" MAX. BETWEEN CONTROL JOINTS

• REFER TO PARTITION TYPES FOR COMPLETE

DESCRIPTION OF COMPONENT PARTS

GYPSUM BOARD

METAL STUD FRAMING

(2) LAYERS TYPE

"X" GYPSUM

BOARD

CONTROL JOINT

GYPSUM BOARD CONTROL

JOINT 2 HOUR RATED

PARTITION

• 1/2" MAXIMUM GAP FOR CONTROL JOINT

• 30'-0" MAX. BETWEEN CONTROL JOINTS

• REFER TO PARTITION TYPES FOR COMPLETE

DESCRIPTION OF COMPONENT PARTS

METAL STUD FRAMING

(2) LAYERS TYPE "X"

GYPSUM BOARD

CONTROL JOINT

(2) LAYERS TYPE

"X" GYPSUM

BOARD

NOTE:

MOUNT EQUIPMENT AS SHOWN UNLESS SPECIFIED OTHERWISE.

MAX TWO DEVICES IN ONE HIGHER MOUNT

LOCATION AT LATCH SIDE OF DOOR, PROVIDE RFI

IF MORE DEVICES ARE NECESSARY. WHERE THERE

IS ONE DEVICE, CENTER OVER LOWER DEVICE. (TO

BE WITHIN ADA HEIGHT). (IF SWITCH CANNOT BE

LOCATED ON LATCH SIDE, LOCATE ONE DOOR

LEAF AWAY ON HINGE SIDE.)

DOOR

LOW DEVICES

RECEPTACLEVOICE/DATA

MASONRY COURSING

(WHERE APPLICABLE)

LIGHT SWITCH

F.A. AUDIO/VISUAL

ALIGNMENT NOTES

• ALIGN AND LOCATE CLOSE TOGETHER ANY DEVICES INSTALLED WITHIN 6' HORIZONTALLY.

• CENTER ALL DEVICES WHERE INDICATED ON COLUMN WRAP OR BUMP OUT; STACK AND ALIGN VERTICALLY.

• INSTALL DEVICES AT HEIGHTS INDICATED IN SYMBOL LEGEND UNLESS STACKING PER THIS DETAIL.

• WHERE HEIGHT IS SPECIFICALLY NOTED ON FLOOR PLANS, USE THAT MOUNTING HEIGHT

• CENTER ON DOORFRAME OR WHITEBOARDS ANY DEVICES INDICATED ABOVE.

O R L

A N D

IN

G

F R O

M F

LO

O

R

F R O

M F

LO

O

R O

R L

A N D

IN

G

6' - 0" MIN.

4" MAX

CAMERAS, CLOCKS, WALL

OCCUPANCY SENSORS

WHITE BOARD (WHERE APPLICABLE -

VERIFY WITH DETAILS/PLANS PROPER

INSTALL HEIGHT) CENTER ANY SINGLE

DEVICE WITH CENTER OF WHITE BOARD

ANY DEVICES

SHOWN OVER DOOR

TO BE CENTERED.

EQ EQ

EQ EQ

F R O

M F

LO

O

R O

R L

A N D

IN

G

SHORT THROW PROJECTOR

WHERE APPLICABLE

~12"

FA PULL STATION - HINGE SIDE

OF DOOR 1-LEAF AWAY WITHIN

5'-0" OF EXTERIOR OR STAIR

DOORS, WHEN WALL MOUNT

STROBES ARE ON PROJECT,

ALIGN ABOVE.

WHEN DEVICES ARE WITHIN DIMENSION, STACK

HIGH/LOW VERTICALLY AND GROUP DEVICES AT

SAME HEIGHT. UNLESS DEVICES IS PART OF

TECHNOLOGY DETAIL GROUPING OR SERVING A

FURNITURE GROUP.

CASEWORK, COORDINATE DEVICE BOTTOM

TO BE 2" OVER BACKSPLASH OR OVER

COUNTERTOP (IF NO BACKSPLASH). FOR

LARGE FORMAT TILE, ALIGN EDGE OF DEVICE

WITH HORIZONTAL GROUT LINE CLOSEST TO

COUNTERTOP.

COORDINATE OUTLET LOCATIONS WITH

GROUT LINES, EDGE OF DEVICE ON GROUT

LINE IF POSSIBLE. COORDINATE WITH

INTERIOR DESIGN DRAWINGS.

TYPICAL COLUMN

ENCLOSURE, CHASE OR

BUMP-OUT WITH DEVICES

INDICATED IN PLANS.

EQ EQ

EQEQEQEQ

THERMOSTAT,

SENSORS OR AV

CONTROLLER, CARD

READER, ETC.

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

G E

N E

R A

L A

R C

H

IT

E C

T U

R A

L N

O T

E S

IN

T E

R

IO

R P

A R

T

IT

IO

N

T Y

P E

S A

N D

D E

V

IC

E A

L

IG

N M

E N

T G

U

ID

E L

IN

E S

.1

A G

E A

S T

L E

R O

Y E

L E

M E

N T

A R

Y M

E C

H A

N

IC

A L

U P

G R

A D

E S

E a s t L e ro y M ic h ig a n

A T

H E

N S

A R

E A

S C

H O

O L S

D E

C E

M B

E R

GENERAL NOTES - ARCHITECTURAL - NEW CONSTRUCTION

1 THE OWNER RESERVES THE RIGHT TO REMOVE ANY ITEM FROM THE PROJECT PRIOR TO

COMMENCEMENT OF CONTRACTED DEMOLITION WORK.

2 ALL EXISTING CONDITIONS SHOULD BE FIELD VERIFIED BEFORE WORK BEGINS.

3 DIMENSIONS GIVEN ARE ACTUAL AND ARE TO THE FACE OF MASONRY UNITS OR TO THE

FACE OF STUD FRAMING, UNLESS NOTED OTHERWISE.

4 DETAILS SHOWN ILLUSTRATE DESIGN INTENT, NOT ALL POSSIBLE CONDITIONS. FOR

CONDITIONS NOT SHOWN, USE DETAILS CLOSEST TO CONDITION IN QUESTION.

5 EXTEND ALL INTERIOR WALL PARTITIONS FROM FLOOR TO STRUCTURE/DECK ABOVE

UNLESS NOTED OR DETAILED OTHERWISE.

6 WITHIN BUILDING INTERIOR PROVIDE BULLNOSE BLOCK IN CMU WALL ASSEMBLIES AT

ALL EXPOSED OUTSIDE CORNERS, INCLUDING WINDOW AND DOOR JAMBS, UNLESS

NOTES OR DETAILED OTHERWISE. PROVIDE SQUARE CORNERS AT ALL LOCATIONS

FINISHED WITH WALL TILE, REFER TO FINISH PLANS (I100 SHEETS) FOR LOCATIONS.

7 TOOTH-IN MASONRY AT NEW OPENINGS IN EXISTING WALLS.

8 TOOTH-IN NEW MASONRY INFILL INTO EXISTING OPENINGS AT ALL BULLNOSE BLOCK

LOCATIONS.

9 STUD WALLS SPANNING OVER 12'-0" IN HEIGHT SHALL BE A MINIMUM OF 20 GAGE.

10 STUD WALL SUPPORTING WALL CABINETS SHALL BE A MINIMUM OF 20 GAGE.

11 DOORS ARE TO BE 4" FROM CORNER OF ROOM, UNLESS NOTED OR DIMENSIONED

OTHERWISE.

12 FIRESTOP ALL INTERCONNECTIONS BETWEEN VERTICAL AND HORIZONTAL SPACES AND

CONCEALED WALL SPACES AT CEILING, FLOOR AND ROOF LEVELS.

13 FIRESEAL ALL PENETRATIONS, SUCH AS, PIPES, DUCTS, CONDUITS, ETC. THROUGH FIRE

AND/OR SMOKE RATED ASSEMBLIES.

14 FOR CONTROL JOINT (C.J.) LOCATIONS REFER TO EXTERIOR ELEVATIONS AND/OR FLOOR

PLANS.

15 PAINT ALL ELECTRICAL PANEL COVERS AND ACCESS PANELS TO MATCH ADJACENT

FINISHES. USING OIL-BASED PAINT, NOT LATEX WALL PAINT.

16 PROVIDE WOOD BLOCKING IN WALLS THAT REQUIRE WALL MOUNTED EQUIPMENT OR

ACCESSORIES. COORDINATE WITH EQUIPMENT OR ACCESSORY MANUFACTURER.

17 ROVIDE ALL ASSOCIATED CURBS FOR ROOF TOP EQUIPMENT AND MECHANICAL ROOF

TOP UNITS. LARGE VOIDS BELOW THE AIR HANDLING UNITS SHALL BE FILLED WITH

INSULATION AS SPECIFIED FOR NOISE CONTROL.

18 ALL EXISTING ROOF TOP PENETRATIONS BEING REMOVED REQUIRE ROOF PATCHING TO

MATCH EXISTING ADJACENT.

GENERAL NOTES - ARCHITECTURAL - DEMOLITION

1 CONTRACTORS ARE REQUIRED TO INSPECT/REVIEW THE EXISTING BUILDING PRIOR TO

RELATED DEMOLITION WORK. UNLESS NOTED OTHERWISE, REMOVAL OF ANY WALL,

FLOOR OR CEILING INCLUDES ALL GENERAL MECHANICAL AND ELECTRICAL ITEMS WHICH

ARE A PART OF, OR ATTACHED TO IT.

2 CONTRACTOR SHALL VERIFY ALL EXISTING JOB SITE CONDITIONS AND DIMENSIONS AND

BE RESPONSIBLE FOR THE SAME ADVISE CONSTRUCTION MANAGER OF ANY AND ALL

DISCREPANCIES.

3 PATCH FLOORS, WALLS AND CEILINGS DAMAGED DURING CONSTRUCTION AND

DEMOLITION AS REQUIRED. FINISH TO MATCH EXISTING.

4 ACCOMMODATE NEW CONSTRUCTION IF NOT INDICATED.

5 PROTECT ALL EXISTING FINISHES THROUGHOUT PROJECT.

6 REFER TO DEMOLITION ELEVATIONS, SECTIONS AND DETAILS FOR ADDITIONAL

INFORMATION.

7 REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL PLANS FOR

ADDITIONAL DEMOLITION NOTES.

8 SALVAGE ALL UNISTRUT AND PROTECT FOR RE-USE IN NEW CONSTRUCTION, IF

REQUIRED.

9 AT LOCATIONS OF REMOVED WALLS, ALL ASSOCIATED ITEMS ATTACHED TO THE WALL

ARE TO BE REMOVED. SUCH AS: DOORS, WINDOWS, FRAMES, MARKERBOARDS,

TACKBOARDS, TACK STRIPS, ETC.

SCALE: NONE

FIRE RATED WALL PLAN DETAILS

3/4" = 1'-0"

INTERIOR PARTITION TYPES

GENERAL NOTES - ARCHITECTURAL - PARTITIONS

1 NOT ALL WALL TYPES MAY BE USED ON PROJECT.

2 REFER TO CODE COMPLIANCE PLANS FOR LOCATIONS OF SMOKE AND FIRE-RATED

PARTITIONS.

3 ALL PARTITIONS EXTEND TO BOTTOM OF STRUCTURE, UNLESS NOTED OTHERWISE.

4 LINE OF STRUCTURE/DECK AS SHOWN AT THE HEAD CONDITION OF EACH PARTITION

TYPE IS DIAGRAMMATIC ONLY AND DOES NOT INDICATE EXACT CONSTRUCTION

CONDITIONS. TERMINATE RATED PARTITIONS AT UNDERSIDE OF STRUCTURAL DECK TO

MAINTAIN RATING. PROVIDE APPROPRIATE FRAMING AND GYPSUM BOARD TO OFFSET

AROUND STRUCTURE OR OTHER OBSTRUCTIONS, SUCH AS PIPING OR DUCTWORK.

5 PARTITIONS MAY TERMINATE AT STRUCTURAL MEMBERS WITH A RATING GREATER THAN

OR EQUAL THE PARTITION, PROVIDED THAT RATING IS CONTINUOUS TO STRUCTURAL

DECK ABOVE.

6 NON-RATED PARTITIONS THAT EXTEND TO STRUCTURE SHALL TERMINATE AT UNDERSIDE

OF STRUCTURAL DECK TO MAINTAIN A CONTINUOUS PLANE OF GYPSUM BOARD AS A

NOISE, SMOKE OR OTHER TYPE OF BARRIER.

7 ALL PARTITIONS EXTENDING TO STRUCTURE ABOVE SHALL TERMINATE WITH DEFLECTION

TRACK - SEE TYPICAL DETAILS ON THIS SHEET.

8 ALL GYPSUM BOARD PARTITIONS NOT EXTENDING TO THE STRUCTURE MUST BE

BRACED.

9 UL DESIGN NUMBERS REFER TO THE FIRE RESISTANCE DIRECTORY; UNDERWRITERS

LABORATORY, LATEST EDITION.

10 MISCELLANEOUS NON-RATED CHASES TO BE 5/8" GYPSUM BOARD ON 3 5/8" METAL

STUD FRAMING AT 16" O.C., UNLESS NOTED OTHERWISE.

11 MISCELLANEOUS FURRING AROUND COLUMNS TO BE 5/8" GYPSUM BOARD ON 11/2"

STUDS, UNLESS NOTED OTHERWISE.

12 FIRE-RATED PARTITIONS TO HAVE FIRE-STOPPING SEALANTS AT HEAD, SILL JUNCTURE

WITH DISSIMILAR MATERIALS, ETC. AND AROUND ALL PENETRATIONS AND OPENINGS.

13 CONSTRUCT ALL PARTITIONS WITH SOUND ATTENUATION BATTS WITH THE FOLLOWING

SOUND BATT THICKNESS: 2 1/2" OR LESS METAL STUD - 1 1/2" THICKNESS, 3 5/8" OR

LARGER METAL STUD - 3" THICKNESS. UNLESS NOTED OTHERWISE.

PARTITION STUD KEY - METAL, CH, AND WOOD

A GYPSUM BOARD DIRECT APPLIED TO CMU

B 7/8"

C 1 1/2"

D 1 5/8"

E 2 1/2"

F 3 1/2"

G 3 5/8"

H 4

J 5 1/2"

K 6"

L 8"

M 10"

N 12"

P OPEN

Q OPEN

R 2 1/2"

S 4"

T 6"

U 2"x4"

V 2"x6"

W 2"x8"

METAL STUD/FURRING

DESIGNATION SIZE

METAL STUD/FURRING

DESIGNATION SIZE

METAL STUD/FURRING

DESIGNATION SIZE

PARTITION TYPE TAG (REFER TO FLOOR PLANS)

1X

PARTITION TYPE NUMBER STUD SIZE DESIGATION

FIRE RATING, IF REQUIRED

1X

LIST OF ABBREVIATIONS

ACP ACOUSTICAL PANEL CEILING

AFF ABOVE FINISH FLOOR

ALUM ALUMINUM

ANOD ANODIZED

CFMF COLD FORMED METAL FRAMING

CMU CONCRETE MASONRY UNIT

CONC CONCRETE

DCMU DECOTATIVE CONCRETE MASONRY UNIT

EIFS EXTERIOR INSULATION AND FINISH SYSTEM

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FRT FIRE RESISTANT TREATED

FV FIELD VERIFY

GYP BD GYPSUM BOARD

HM HOLLOW METAL

LVL LAMINATED VENEER LUMBER

MCM METAL COMPOSITE MATERIAL WALL PANEL

OC ON CENTER

PT PRESERVATIVE TREATED

PNT PAINT

SS STAINLESS STEEL

SSM SOLID SURFACE MATERIAL

TYP TYPICAL

VIF VERIFY IN FEILD

WD WOOD

12" = 1'-0"

DEVICE ALIGNMENT GUIDELINES

T

T

T

EQ

EQ

EQ

EQ

EQ EQ EQ

EQ

EQ

OFFICE

LOBBY

MEN'S

TOILET

WOMEN'S

TOILET

BOILER ROOM

KITCHEN

TOILET

KITCHEN

STORAGE

STORAGE

MULTI-PURPOSE

ROOM

CLASSROOM

TOILET

TOILET

CLASSROOM

VIF

7' - 0" 2' - 0"

V

IF

VIF

7' - 0" 2' - 0"

V

IF

/2

UNIT

B

UNIT

A

UNIT A

UNIT C

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

F

IR

S T

F L O

O R

D E

M O

L

IT

IO

N

P L A

N

U N

IT

A 2 .1

A D

A

E A

S T

L E

R O

Y E

L E

M E

N T

A R

Y M

E C

H A

N

IC

A L

U P

G R

A D

E S

E a s t L e ro y M ic h ig a n

A T

H E

N S

A R

E A

S C

H O

O L S

D E

C E

M B

E R

THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN

COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,

IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN

AN ACCURATE DRAWING

KEYED NOTES - ARCHITECTURAL - DEMOLITION

1 REMOVE CEILING TILES AS NEEDED TO ACCOMMODATE NEW MECHANICAL PIPING AND

ELECTRICAL CONDUIT INSTALLATION. REFER TO MEP DRAWINGS FOR MORE

INFORMATION

2 REMOVE AND DISPOSE OF EXISTING DOOR AND FRAME. PREP OPENING FOR NEW

DOOR AND FRAME.

3 REMOVE EXISTING HORIZONTAL UNIT VENT AND PREP FOR NEW. REFER TO

MECHANICAL FOR MORE INFORMATION

4 REMOVE AND DISPOSE OF EXISITNG GLASS TRANSOM OVER DOOR TO ACCOMMODATE

NEW PIPING INSTALLATION. PREP OPENING FOR NEW 1 HOUR RATED INFILL

5 CUT NEW 12" X 24" OPENING IN EXISTING STEEL DECK. REFER TO LONG SPAN DECK

DETAIL 1 ON A 102 AND MECHANICAL FOR MORE INFORMATION

6 REMOVE PORTION OF EXISTING BULLETIN BOARD TO ACCOMMODATE NEW VERTICAL

PIPE ENCLOSURE

7 REMOVE PORTION OF EXISTING BOOKCASE TO ACCOMMODATE NEW CEILING MOUNTED

PIPE ENCLOSURE. REMOVE ONLY ENOUGH TO ACCOMMODATE NEW PIPE COVER

8 REMOVE AND SALVAGE EXISTING PIPE ENCLOSURE TO ACCOMMODATE NEW PIPING

INSTALLATION. REINSTALL AFTER COMPLETION. SEE MECHANICAL FOR MORE

INFORMATION.

9 REMOVE EXISTING HORIZONTAL UNIT VENT AND PREP FOR NEW. REFER TO

MECHANICAL FOR MORE INFORMATION

10 REMOVE PORTION OF EXISTING ROOFING DOWN TO EXISTING DECK TO ACCOMMODATE

NEW RELIEF HOOD INSTALLATION. COORDINATE WITH MECHANICAL FOR SIZE AND

LOCATION. NOTE, AT STRUCTURAL METAL DECK, SEE DETAIL TO ADD STEEL PLATE AND

COORDINATE WITH MECHANICAL FOR INSTALLATION OF NEW RELIEF HOOD CURB.

11 REMOVE PORTION OF EXISTING GYPSUM BOARD FINISH TO ACCOMMODATE NEW

PIPING INSTALLATION WITHIN EXISTNG STUD WALL FOR NEW MECHANICAL UNIT. REFER

TO MECHANICAL AND ELECTRICAL FOR MORE INFORMATION.

12 SHIFT EXISTING TOILET PAPER DISPENSER TO ALLOW INSTALLATION OF NEW HYDRONIC

PIPING AND ENCLOSURE.

13 REMOVE EXISTING ENCLOSURE AT REFRIGERANT LINES. REFRIGERANT LINES TO REMAIN

AND BE ENCLOSED WITHIN NEW VERTICAL ENCLOSURE

14 REMOVE AND SALVAGE EXISTING WINDOW SHADE DEVICE TO ACCOMMODATE PIPE AND

VERTICAL ENCLOSURE INSTALLATION

1/8" = 1'-0"

FIRST FLOOR DEMOLITION - UNIT A

EAST LEROY ELEMENTARY

UNIT

A

UNIT B UNIT C

KEY PLAN

TT

TTT

TT

T

T T

T

T T

T

T

EQ EQ EQ

EQ

EQ EQ

EQ EQ EQ

WAPWAP

WAP

WAP WAPWAP

CORRIDOR

CLASSROOM

CLASSROOM

CLASSROOM

CUSTODIAN

TOILET

STAFF

CONFERENCE

VAULT

OFFICE

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

152CLASSROOM

CLASSROOM

CONFERENCE

3 3

3 3 3

1 1

3 3

5 5

4' - 0" 2' - 0"

V

IF

4' - 0"

2' - 0"

V

IF

/2

4' - 0" 2' - 0"

V

IF

4' - 0" 2' - 0"

V

IF

4' - 0" 2' - 0" 1

V

IF

4' - 0" 2' - 0" 1

V

IF

SEE IMAGE

ONE THIS

SHEET

SEE IMAGE

TWO THIS

SHEET

SEE IMAGE

ONE THIS

SHEET

(SIMILAR)

UNIT B UNIT C

UNIT

B

UNIT

A

UNIT A

UNIT C

CORRIDOR

CORRIDOR

CORRIDOR

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

F

IR

S T

F L O

O R

D E

M O

L

IT

IO

N

P L A

N

U N

IT

B

.1

A D

B

E A

S T

L E

R O

Y E

L E

M E

N T

A R

Y M

E C

H A

N

IC

A L

U P

G R

A D

E S

E a s t L e ro y M ic h ig a n

A T

H E

N S

A R

E A

S C

H O

O L S

D E

C E

M B

E R

1/8" = 1'-0"

FIRST FLOOR DEMOLITION - UNIT B

THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN

COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,

IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN

AN ACCURATE DRAWING

KEYED NOTES - ARCHITECTURAL - DEMOLITION

1 REMOVE CEILING TILES AS NEEDED TO ACCOMMODATE NEW MECHANICAL PIPING AND

ELECTRICAL CONDUIT INSTALLATION. REFER TO MEP DRAWINGS FOR MORE

INFORMATION

2 REMOVE AND DISPOSE OF EXISTING DOOR AND FRAME. PREP OPENING FOR NEW

DOOR AND FRAME.

3 REMOVE EXISTING HORIZONTAL UNIT VENT AND PREP FOR NEW. REFER TO

MECHANICAL FOR MORE INFORMATION

4 REMOVE AND DISPOSE OF EXISITNG GLASS TRANSOM OVER DOOR TO ACCOMMODATE

NEW PIPING INSTALLATION. PREP OPENING FOR NEW 1 HOUR RATED INFILL

5 CUT NEW 12" X 24" OPENING IN EXISTING STEEL DECK. REFER TO LONG SPAN DECK

DETAIL 1 ON A 102 AND MECHANICAL FOR MORE INFORMATION

6 REMOVE PORTION OF EXISTING BULLETIN BOARD TO ACCOMMODATE NEW VERTICAL

PIPE ENCLOSURE

7 REMOVE PORTION OF EXISTING BOOKCASE TO ACCOMMODATE NEW CEILING MOUNTED

PIPE ENCLOSURE. REMOVE ONLY ENOUGH TO ACCOMMODATE NEW PIPE COVER

8 REMOVE AND SALVAGE EXISTING PIPE ENCLOSURE TO ACCOMMODATE NEW PIPING

INSTALLATION. REINSTALL AFTER COMPLETION. SEE MECHANICAL FOR MORE

INFORMATION.

9 REMOVE EXISTING HORIZONTAL UNIT VENT AND PREP FOR NEW. REFER TO

MECHANICAL FOR MORE INFORMATION

10 REMOVE PORTION OF EXISTING ROOFING DOWN TO EXISTING DECK TO ACCOMMODATE

NEW RELIEF HOOD INSTALLATION. COORDINATE WITH MECHANICAL FOR SIZE AND

LOCATION. NOTE, AT STRUCTURAL METAL DECK, SEE DETAIL TO ADD STEEL PLATE AND

COORDINATE WITH MECHANICAL FOR INSTALLATION OF NEW RELIEF HOOD CURB.

11 REMOVE PORTION OF EXISTING GYPSUM BOARD FINISH TO ACCOMMODATE NEW

PIPING INSTALLATION WITHIN EXISTNG STUD WALL FOR NEW MECHANICAL UNIT. REFER

TO MECHANICAL AND ELECTRICAL FOR MORE INFORMATION.

12 SHIFT EXISTING TOILET PAPER DISPENSER TO ALLOW INSTALLATION OF NEW HYDRONIC

PIPING AND ENCLOSURE.

13 REMOVE EXISTING ENCLOSURE AT REFRIGERANT LINES. REFRIGERANT LINES TO REMAIN

AND BE ENCLOSED WITHIN NEW VERTICAL ENCLOSURE

14 REMOVE AND SALVAGE EXISTING WINDOW SHADE DEVICE TO ACCOMMODATE PIPE AND

VERTICAL ENCLOSURE INSTALLATION

EAST LEROY ELEMENTARY

UNIT

A

UNIT B UNIT C

KEY PLAN

SCALE: NO SCALE

IMAGE ONE IMAGE TWO

REMOVE EXISTING GLASS TRANSOM

AND PREP FOR NEW 1-HOUR

ENCLOSURE

REMOVE AND SALVAGE EXISTING

PIPE ENCLOSURE. SAVE FOR RE-

INSTALLATION

T T T

T

T

T

T

T

T

T

T

T

T

T

EQ

EQ EQ EQ EQ

EQEQEQ

CORRIDOR

CUSTODIAN

TOILET

STAFF

CONFERENCE

VAULT

OFFICE

132 VESTIBULE

LIBRARY

DATA

RELATED

ACTIVITIES

COUNSELOR

COMPUTER

LAB

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

HEALTH

TOILET

OFFICE

3 3

3 3 3 3

3 3 3

SEE IMAGE

ONE THIS

SHEET

SEE IMAGE

THREE THIS

SHEET

SEE IMAGE

TWO THIS

SHEET

SEE IMAGE

FOUR THIS

SHEET

SEE IMAGE

FIVE THIS

SHEET

SEE IMAGE

SIX THIS

SHEET

2' - 0" 4' - 0"

V

IF

2' - 0" 4' - 0"

V

IF

6' - 0" 2' - 0"

V

IF

EQ. 2' - 0" EQ.

V

IF

2' - 0" 3' - 4 1/2"

V

IF

2' - 0" 4' - 0"

V

IF

2' - 0" 4' - 0"

V

IF

6' - 0" 2' - 0"

" V

IF

UNIT B UNIT C

UNIT A

UNIT C

SEE IMAGE

SEVEN THIS

SHEET

13 14

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

F

IR

S T

F L O

O R

D E

M O

L

IT

IO

N

P L A

N

U N

IT

C

.1

A D

C

E A

S T

L E

R O

Y E

L E

M E

N T

A R

Y M

E C

H A

N

IC

A L

U P

G R

A D

E S

E a s t L e ro y M ic h ig a n

A T

H E

N S

A R

E A

S C

H O

O L S

D E

C E

M B

E R

1/8" = 1'-0"

FIRST FLOOR DEMOLITION - UNIT C

THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN

COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,

IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN

AN ACCURATE DRAWING

KEYED NOTES - ARCHITECTURAL - DEMOLITION

1 REMOVE CEILING TILES AS NEEDED TO ACCOMMODATE NEW MECHANICAL PIPING AND

ELECTRICAL CONDUIT INSTALLATION. REFER TO MEP DRAWINGS FOR MORE

INFORMATION

2 REMOVE AND DISPOSE OF EXISTING DOOR AND FRAME. PREP OPENING FOR NEW

DOOR AND FRAME.

3 REMOVE EXISTING HORIZONTAL UNIT VENT AND PREP FOR NEW. REFER TO

MECHANICAL FOR MORE INFORMATION

4 REMOVE AND DISPOSE OF EXISITNG GLASS TRANSOM OVER DOOR TO ACCOMMODATE

NEW PIPING INSTALLATION. PREP OPENING FOR NEW 1 HOUR RATED INFILL

5 CUT NEW 12" X 24" OPENING IN EXISTING STEEL DECK. REFER TO LONG SPAN DECK

DETAIL 1 ON A 102 AND MECHANICAL FOR MORE INFORMATION

6 REMOVE PORTION OF EXISTING BULLETIN BOARD TO ACCOMMODATE NEW VERTICAL

PIPE ENCLOSURE

7 REMOVE PORTION OF EXISTING BOOKCASE TO ACCOMMODATE NEW CEILING MOUNTED

PIPE ENCLOSURE. REMOVE ONLY ENOUGH TO ACCOMMODATE NEW PIPE COVER

8 REMOVE AND SALVAGE EXISTING PIPE ENCLOSURE TO ACCOMMODATE NEW PIPING

INSTALLATION. REINSTALL AFTER COMPLETION. SEE MECHANICAL FOR MORE

INFORMATION.

9 REMOVE EXISTING HORIZONTAL UNIT VENT AND PREP FOR NEW. REFER TO

MECHANICAL FOR MORE INFORMATION

10 REMOVE PORTION OF EXISTING ROOFING DOWN TO EXISTING DECK TO ACCOMMODATE

NEW RELIEF HOOD INSTALLATION. COORDINATE WITH MECHANICAL FOR SIZE AND

LOCATION. NOTE, AT STRUCTURAL METAL DECK, SEE DETAIL TO ADD STEEL PLATE AND

COORDINATE WITH MECHANICAL FOR INSTALLATION OF NEW RELIEF HOOD CURB.

11 REMOVE PORTION OF EXISTING GYPSUM BOARD FINISH TO ACCOMMODATE NEW

PIPING INSTALLATION WITHIN EXISTNG STUD WALL FOR NEW MECHANICAL UNIT. REFER

TO MECHANICAL AND ELECTRICAL FOR MORE INFORMATION.

12 SHIFT EXISTING TOILET PAPER DISPENSER TO ALLOW INSTALLATION OF NEW HYDRONIC

PIPING AND ENCLOSURE.

13 REMOVE EXISTING ENCLOSURE AT REFRIGERANT LINES. REFRIGERANT LINES TO REMAIN

AND BE ENCLOSED WITHIN NEW VERTICAL ENCLOSURE

14 REMOVE AND SALVAGE EXISTING WINDOW SHADE DEVICE TO ACCOMMODATE PIPE AND

VERTICAL ENCLOSURE INSTALLATION

EAST LEROY ELEMENTARY

UNIT

A

UNIT B UNIT C

KEY PLAN

SCALE: NO SCALE

IMAGE ONE IMAGE TWO IMAGE THREE

IMAGE FOUR IMAGE FIVE IMAGE SIX

REMOVE SECTION OF BULLETIN

BOARD TO ACCOMMODATE NEW

HYDRONIC PIPING INSTALLATION

AND BENT METAL SHROUD

REMOVE 12" WIDE SECTION

FROM BULLETIN BOARD TO

ACCOMMODATE NEW PIPING AND

SHROUD INSTALLATION

REMOVE PORTION OF EXISTING

SHELVING TO ACCOMMODATE

NEW PIPING INSTALLATION

REMOVE EXISTING ENCLOSURE.

REFRIGERANT LINES TO REMAIN

AND BE CONCEALED WITHIN NEW

VERTICAL ENCLOSURE

COORDINATE W/ NEW PIPING

INSTALLATION

COORDINATE W/ NEW PIPING

AND METAL SHROUD INSTALLATION

IMAGE SEVEN

REMOVE EXISTING SHELVING UNIT

TO ACCOMMODATE NEW VERTICAL

PIPE ENCLOSURE

IMAGE EIGHT

RELOCATE EXISTING SHELVING UNIT

TO ACCOMMODATE NEW VERTICAL

PIPE ENCLOSURE

TT

T

T T

T T T

TTT

T

T

T

T

T

T

T

T

T

T

T T

T

T

T

T

T

EQ EQ EQ

EQ

EQ

EQ EQ

EQ EQ EQ EQ EQ EQ EQ

EQEQEQ

EQ

EQ

EQ

EQ

EQ EQ EQ

EQ

EQ

WAPWAP

WAP

WAP WAPWAP

10 10

10 10

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

O V

E R

A L L R

O O

F D

E M

O L

IT

IO

N

P L A

N

.1

A D

E A

S T

L E

R O

Y E

L E

M E

N T

A R

Y M

E C

H A

N

IC

A L

U P

G R

A D

E S

E a s t L e ro y M ic h ig a n

A T

H E

N S

A R

E A

S C

H O

O L S

D E

C E

M B

E R

THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN

COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,

IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN

AN ACCURATE DRAWING

KEYED NOTES - ARCHITECTURAL - DEMOLITION

1 REMOVE CEILING TILES AS NEEDED TO ACCOMMODATE NEW MECHANICAL PIPING AND

ELECTRICAL CONDUIT INSTALLATION. REFER TO MEP DRAWINGS FOR MORE

INFORMATION

2 REMOVE AND DISPOSE OF EXISTING DOOR AND FRAME. PREP OPENING FOR NEW

DOOR AND FRAME.

3 REMOVE EXISTING HORIZONTAL UNIT VENT AND PREP FOR NEW. REFER TO

MECHANICAL FOR MORE INFORMATION

4 REMOVE AND DISPOSE OF EXISITNG GLASS TRANSOM OVER DOOR TO ACCOMMODATE

NEW PIPING INSTALLATION. PREP OPENING FOR NEW 1 HOUR RATED INFILL

5 CUT NEW 12" X 24" OPENING IN EXISTING STEEL DECK. REFER TO LONG SPAN DECK

DETAIL 1 ON A 102 AND MECHANICAL FOR MORE INFORMATION

6 REMOVE PORTION OF EXISTING BULLETIN BOARD TO ACCOMMODATE NEW VERTICAL

PIPE ENCLOSURE

7 REMOVE PORTION OF EXISTING BOOKCASE TO ACCOMMODATE NEW CEILING MOUNTED

PIPE ENCLOSURE. REMOVE ONLY ENOUGH TO ACCOMMODATE NEW PIPE COVER

8 REMOVE AND SALVAGE EXISTING PIPE ENCLOSURE TO ACCOMMODATE NEW PIPING

INSTALLATION. REINSTALL AFTER COMPLETION. SEE MECHANICAL FOR MORE

INFORMATION.

9 REMOVE EXISTING HORIZONTAL UNIT VENT AND PREP FOR NEW. REFER TO

MECHANICAL FOR MORE INFORMATION

10 REMOVE PORTION OF EXISTING ROOFING DOWN TO EXISTING DECK TO ACCOMMODATE

NEW RELIEF HOOD INSTALLATION. COORDINATE WITH MECHANICAL FOR SIZE AND

LOCATION. NOTE, AT STRUCTURAL METAL DECK, SEE DETAIL TO ADD STEEL PLATE AND

COORDINATE WITH MECHANICAL FOR INSTALLATION OF NEW RELIEF HOOD CURB.

11 REMOVE PORTION OF EXISTING GYPSUM BOARD FINISH TO ACCOMMODATE NEW

PIPING INSTALLATION WITHIN EXISTNG STUD WALL FOR NEW MECHANICAL UNIT. REFER

TO MECHANICAL AND ELECTRICAL FOR MORE INFORMATION.

12 SHIFT EXISTING TOILET PAPER DISPENSER TO ALLOW INSTALLATION OF NEW HYDRONIC

PIPING AND ENCLOSURE.

13 REMOVE EXISTING ENCLOSURE AT REFRIGERANT LINES. REFRIGERANT LINES TO REMAIN

AND BE ENCLOSED WITHIN NEW VERTICAL ENCLOSURE

14 REMOVE AND SALVAGE EXISTING WINDOW SHADE DEVICE TO ACCOMMODATE PIPE AND

VERTICAL ENCLOSURE INSTALLATION

EAST LEROY ELEMENTARY

UNIT

A

UNIT B UNIT C

KEY PLAN

SCALE: NO SCALE

3/32" = 1'-0"

OVERALL ROOF DEMOLITION PLAN

TS

T S

T

T S

EQ

EQ

EQ

EQ

EQ

EQ EQ EQ EQ

EQ EQ

EQ EQ

EQ

EQ

EQ EQ EQEQ

J

J

EQ

EQ

BOILER ROOM

MEN'S

TOILET

WOMEN'S

TOILET

MULTI-PURPOSE

ROOM

CLASSROOM

LOBBY

KITCHEN

TOILET

KITCHEN

STORAGE

STORAGE

CLASSROOM

TOILET

TOILET

A 101A

A 101A

SIM

A 101A

SIM

140A

140B

UNIT

B

UNIT

A

UNIT A

UNIT C

UPPER ROOF 2

108' - 8"

6"

16 GA BREAK METAL

ENCLOSURE W/ NO EXPOSED

FASTENERS. PAINT COLOR

TO MATCH WALL COLOR

PIPE AND INSULATION,

SEE MECHANICAL

CONCEALED FASTENER

CLIP W/ MASONRY

SCREWS

EXISTING CEILING TO

REMAIN, WHERE

APPLICABLE

'-0

A .F

.F

6"

18 GA REMOVABLE BREAK

METAL ENCLOSURE W/ NO

EXPOSED FASTENERS. PAINT

COLOR TO MATCH WALL

COLOR. EXTEND FROM FINISH

FLOOR TO HEIGHT OF 8'-2" AFF.

PIPE AND INSULATION,

SEE MECHANICAL AND

ELECTRICAL

CONCEALED FASTENER

CLIP W/ MASONRY SCREWS

LF

R E F E R T

O S

C H E D

U

LE

SCHED.

REFER TO

R E F E R T

O S

C H E D

U

LE

SCHED.

REFER TO

SCHED.

REFER TO 2"

R E F E R T

O S

C H E D

U

LE

F

IE

LD

V

E R

IF

Y

2"

TO SCHED.

REFER 2"

INSULATED

GLASS

LOWER LEVEL

96' - 0"

6"

18 GA REMOVABLE BREAK

METAL ENCLOSURE W/ NO

EXPOSED FASTENERS. PAINT

COLOR TO MATCH WALL

COLOR

PIPE AND INSULATION,

SEE MECHANICAL AND

ELECTRICAL

CONCEALED FASTENER

CLIP W/ MASONRY

SCREWS

5/8" GYPSUM BOARD,

BOTH SIDES

METAL STUDS AT

16" O.C.

METAL STUD

DOUBLE HEADER

HOLLOW METAL

FRAME - SEE SCHEDULE

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

F

IR

S T

F L O

O R

P L A

N

U N

IT

A

.1

A

A

E A

S T

L E

R O

Y E

L E

M E

N T

A R

Y M

E C

H A

N

IC

A L

U P

G R

A D

E S

E a s t L e ro y M ic h ig a n

A T

H E

N S

A R

E A

S C

H O

O L S

D E

C E

M B

E R

NOTES - ARCHITECTURAL

1 REFER TO CODE COMPLIANCE PLAN FOR WALL RATING LINES.

2 REFER TO FLOOR FINISH PLANS FOR INTERIOR ELEVATION CALLOUTS.

3 REFER TO SHEET A 500's FOR WALL AND CEILING ACCESS PANEL INFORMATION.

EAST LEROY ELEMENTARY

UNIT

A

UNIT B UNIT C

KEY PLAN

SCALE: NO SCALE

1/8" = 1'-0"

FIRST FLOOR PLAN - UNIT A

KEYED NOTES - ARCHITECTURAL - CONSTRUCTION

1 PATCH EXISITNG GYPSUM BOARD VENEER WHERE REMOVED TO ACCOMMODATE NEW

PIPING INSTALLATION. PAINT ENTIRE WALL. COLOR TO BE SELECTED BY OWNER /

ARCHITECT

2 NEW PAINTED METAL VERTICAL PIPE COVER ENCLOSURE, REFER TO DETAIL 2 ON SHEET

A 101A. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW

3 NEW PAINTED METAL PIPE COVER ENCLOSURE, ABOVE. REFER TO DETAIL 1 ON A

101B. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW

4 INFILL DOOR TRANSOM W/ (1) LAYER OF 5/8" TYPE 'X' GYPSUM BOARD ON BOTH SIDES

TO REPLACE RATED GLASS. PAINT TO MATCH EXISTING WALL COLOR.

5 NEW CEILING MOUNTED PAINTED METAL PIPE ENCLOSURE

6 PAINTED STEEL PLATE AT RELIEF OPENING, COLOR TO MATCH EXISTING METAL DECK.

SEE LONG SPAN DECK DETAIL 1 ON SHEET A 102 AND SEE MECHANICAL FOR MORE

INFORMATION

7 REINSTALL EXISTING PIPE ENCLOSURE COVER.

9 NEW ROOF PENETRATION, SEE MECHANICAL AND TYPICAL LONG-SPAN ROOF DECK

PENETRATION WITHOUT SUPPORT FRAMING DETAIL 1 ON SHEET A 102 FOR MORE

INFORMATION. PATCH AND REPAIR ROOFING TO MATCH EXISTING ISULATION AND

MEMBRANE. PROVIDE NEW ROOF CURB FOR RELIEF HOOD. PROVIDE CRICKETS AS

NECESSARY TO DIRECT WATER TO EXISTING DRAINS.

11 NEW MECHANICAL FLU PENETRATION, PATCH AND SEAL ROOF TO MATCH EXISTING.

REFER TO MECHANICAL.

12 PROVIDE NEW 1 HOUR STUD AND GYPSUM BOARD ENCLOSTURE AT TRANSOM ABOVE

DOOR

13 PATCH AND PAINT WALL WHERE WALL MOUNTED UNIT IS REPLACED.

14 NEW WALL MOUNTED HORIZONTAL PAINTED METAL PIPE COVER ENCLOSURE, SEE DETAIL

3 ON A 101A

1 1/2" = 1'-0"A 101A

1 TYP GYM WALL PIPE COVER

1 1/2" = 1'-0"A 101A

2 TYP VERTICAL PIPE COVER

FIRST FLOOR DOOR SCHEDULE

DOOR ROOM

ROOM NAME

FIRE RATING DOOR SIZE FRAME DETAILS

GLASS

ACCESS CONTROLS

HDWR. SET REMARKS

DOOR FRAME TYPE MAT FIN WIDTH HEIGHT ELEV MAT FIN HEAD JAMB SILL A-PHONE

BARRIER-F

REE

CARD

READER

ELEC. LOCK

HDWR. MAG HOLD

140A 140 BOILER ROOM - - F HM P-? 3' - 8" 6' - 8" 2 HM P-? - - - - No No No No No - -

140B 140 BOILER ROOM 45 MIN 45 MIN F HM P-? 3' - 4" 6' - 8" 1 HM P-? H1 - - - No No No No No - -

1/4" = 1'-0"

DOOR ELEVATION LEGEND

1/4" = 1'-0"

FRAME ELEVATION LEGEND

1 1/2" = 1'-0"A 101A

3 TYPICAL HORIZONTAL WALL PIPE COVER

1 1/2" = 1'-0"

H1

UP

TSTS

TSTSTS

TST

S

T

T S

T S

T T

T

T

EQ EQ

EQ

EQ

EQ EQ

EQ EQ

EQ

WAPWAP

WAP

S

WAP WAPWAP

A 101A

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CUSTODIAN

106 STAFF

CONFERENCE

GIRL'S TOILET

VAULT

OFFICE

CLASSROOM

152CLASSROOM

CLASSROOM

CONFERENCE

TOILET

152A

TOILET

153A

TOILET

154A CORRIDOR

CORRIDOR

7 2

UNIT B UNIT C

UNIT

B

UNIT

A

UNIT A

UNIT C

2 2 2

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

F

IR

S T

F L O

O R

P L A

N

U N

IT

B

.1

A

B

E A

S T

L E

R O

Y E

L E

M E

N T

A R

Y M

E C

H A

N

IC

A L

U P

G R

A D

E S

E a s t L e ro y M ic h ig a n

A T

H E

N S

A R

E A

S C

H O

O L S

D E

C E

M B

E R

NOTES - ARCHITECTURAL

1 REFER TO CODE COMPLIANCE PLAN FOR WALL RATING LINES.

2 REFER TO FLOOR FINISH PLANS FOR INTERIOR ELEVATION CALLOUTS.

3 REFER TO SHEET A 500's FOR WALL AND CEILING ACCESS PANEL INFORMATION.

KEYED NOTES - ARCHITECTURAL - CONSTRUCTION

1 PATCH EXISITNG GYPSUM BOARD VENEER WHERE REMOVED TO ACCOMMODATE NEW

PIPING INSTALLATION. PAINT ENTIRE WALL. COLOR TO BE SELECTED BY OWNER /

ARCHITECT

2 NEW PAINTED METAL VERTICAL PIPE COVER ENCLOSURE, REFER TO DETAIL 2 ON SHEET

A 101A. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW

3 NEW PAINTED METAL PIPE COVER ENCLOSURE, ABOVE. REFER TO DETAIL 1 ON A

101B. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW

4 INFILL DOOR TRANSOM W/ (1) LAYER OF 5/8" TYPE 'X' GYPSUM BOARD ON BOTH SIDES

TO REPLACE RATED GLASS. PAINT TO MATCH EXISTING WALL COLOR.

5 NEW CEILING MOUNTED PAINTED METAL PIPE ENCLOSURE

6 PAINTED STEEL PLATE AT RELIEF OPENING, COLOR TO MATCH EXISTING METAL DECK.

SEE LONG SPAN DECK DETAIL 1 ON SHEET A 102 AND SEE MECHANICAL FOR MORE

INFORMATION

7 REINSTALL EXISTING PIPE ENCLOSURE COVER.

9 NEW ROOF PENETRATION, SEE MECHANICAL AND TYPICAL LONG-SPAN ROOF DECK

PENETRATION WITHOUT SUPPORT FRAMING DETAIL 1 ON SHEET A 102 FOR MORE

INFORMATION. PATCH AND REPAIR ROOFING TO MATCH EXISTING ISULATION AND

MEMBRANE. PROVIDE NEW ROOF CURB FOR RELIEF HOOD. PROVIDE CRICKETS AS

NECESSARY TO DIRECT WATER TO EXISTING DRAINS.

11 NEW MECHANICAL FLU PENETRATION, PATCH AND SEAL ROOF TO MATCH EXISTING.

REFER TO MECHANICAL.

12 PROVIDE NEW 1 HOUR STUD AND GYPSUM BOARD ENCLOSTURE AT TRANSOM ABOVE

DOOR

13 PATCH AND PAINT WALL WHERE WALL MOUNTED UNIT IS REPLACED.

14 NEW WALL MOUNTED HORIZONTAL PAINTED METAL PIPE COVER ENCLOSURE, SEE DETAIL

3 ON A 101A

1/8" = 1'-0"

FIRST FLOOR PLAN - UNIT B

EAST LEROY ELEMENTARY

UNIT

A

UNIT B UNIT C

KEY PLAN

UP

TS TS TS

TSTSTS

T

T

T

T

T S

T

T

T S

T

T

EQ EQ EQ EQ

EQEQEQ

EQ

CORRIDOR

VESTIBULE

CUSTODIAN

TOILET

STAFF

CONFERENCE

LIBRARY

DATA

RELATED

ACTIVITIES

COUNSELOR

113 COMPUTER

LAB

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

BOY'S TOILET

HEALTH

TOILET

OFFICE

GIRL'S TOILET

VAULT

OFFICE

OFFICE

WORK ROOM

A 101A

SIM

A 101A

UNIT B UNIT C

UNIT A

UNIT C

2 2

2 2 2

V

IF

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

F

IR

S T

F L O

O R

P L A

N

U N

IT

C

.1

A

C

E A

S T

L E

R O

Y E

L E

M E

N T

A R

Y M

E C

H A

N

IC

A L

U P

G R

A D

E S

E a s t L e ro y M ic h ig a n

A T

H E

N S

A R

E A

S C

H O

O L S

D E

C E

M B

E R

NOTES - ARCHITECTURAL

1 REFER TO CODE COMPLIANCE PLAN FOR WALL RATING LINES.

2 REFER TO FLOOR FINISH PLANS FOR INTERIOR ELEVATION CALLOUTS.

3 REFER TO SHEET A 500's FOR WALL AND CEILING ACCESS PANEL INFORMATION.

KEYED NOTES - ARCHITECTURAL - CONSTRUCTION

1 PATCH EXISITNG GYPSUM BOARD VENEER WHERE REMOVED TO ACCOMMODATE NEW

PIPING INSTALLATION. PAINT ENTIRE WALL. COLOR TO BE SELECTED BY OWNER /

ARCHITECT

2 NEW PAINTED METAL VERTICAL PIPE COVER ENCLOSURE, REFER TO DETAIL 2 ON SHEET

A 101A. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW

3 NEW PAINTED METAL PIPE COVER ENCLOSURE, ABOVE. REFER TO DETAIL 1 ON A

101B. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW

4 INFILL DOOR TRANSOM W/ (1) LAYER OF 5/8" TYPE 'X' GYPSUM BOARD ON BOTH SIDES

TO REPLACE RATED GLASS. PAINT TO MATCH EXISTING WALL COLOR.

5 NEW CEILING MOUNTED PAINTED METAL PIPE ENCLOSURE

6 PAINTED STEEL PLATE AT RELIEF OPENING, COLOR TO MATCH EXISTING METAL DECK.

SEE LONG SPAN DECK DETAIL 1 ON SHEET A 102 AND SEE MECHANICAL FOR MORE

INFORMATION

7 REINSTALL EXISTING PIPE ENCLOSURE COVER.

9 NEW ROOF PENETRATION, SEE MECHANICAL AND TYPICAL LONG-SPAN ROOF DECK

PENETRATION WITHOUT SUPPORT FRAMING DETAIL 1 ON SHEET A 102 FOR MORE

INFORMATION. PATCH AND REPAIR ROOFING TO MATCH EXISTING ISULATION AND

MEMBRANE. PROVIDE NEW ROOF CURB FOR RELIEF HOOD. PROVIDE CRICKETS AS

NECESSARY TO DIRECT WATER TO EXISTING DRAINS.

11 NEW MECHANICAL FLU PENETRATION, PATCH AND SEAL ROOF TO MATCH EXISTING.

REFER TO MECHANICAL.

12 PROVIDE NEW 1 HOUR STUD AND GYPSUM BOARD ENCLOSTURE AT TRANSOM ABOVE

DOOR

13 PATCH AND PAINT WALL WHERE WALL MOUNTED UNIT IS REPLACED.

14 NEW WALL MOUNTED HORIZONTAL PAINTED METAL PIPE COVER ENCLOSURE, SEE DETAIL

3 ON A 101A

EAST LEROY ELEMENTARY

UNIT

A

UNIT B UNIT C

KEY PLAN

SCALE: NO SCALE

1/8" = 1'-0"

A 101C - FIRST FLOOR PLAN - UNIT C

UNIT A

UNIT C

UNIT B UNIT C

UNIT

B

UNIT

A

ROOF DECK

INSULATION

FLASHING

VENT PIPE

SEALANT

ROOFING

CANT STRIP

11/2" RIGID INSULATION

EXISTING ROOF CURB

COUNTER FLASHING WITH

APPROVED SEALING WASHER

AND FASTENER @ 6" O.C.

EXISTING ROOF MOUNTED EQUIPMENT

TREATED 2x4 NAILER, AS REQUIRED

M

IN

LAP SEALANT

MEMBRANE ROOF

EXISTING TREATED NAILER(s)

EXISTING ROOF DECK

EXISTING RIGID

INSULATION TO REAMAIN

ROOF STRUCTURE (SEE

STRUCTURAL)

TREATED NAILER(s) AS REQUIRED

ROOF DECK

CANT STRIP

11/2" RIGID INSULATION

EXISTING ROOF CURB

COUNTER FLASHING WITH

APPROVED SEALING WASHER

AND FASTENER @ 6" O.C.

EXISTING ROOF MOUNTED EQUIPMENT

TREATED 2x4 NAILER, AS REQUIRED

M

IN

LAP SEALANT

MEMBRANE ROOF

EXISTING RIGID

INSULATION TO REAMAIN

NOTE:

FOR TYPICAL INSTANCES BELOW AHU's &

RTU's WHERE ROOF DECK RUNS

CONTINUOUS, PROVIDE NOISE ISOLATION

REQUIREMENTS USING (2) LAYERS OF

5/8" GYPSUM BOARD (TOP & BOTTOM (4

TOTAL)) WITH (2) LAYERS OF 1-1/2"

MINERAL FIBER INSULATION BETWEEN.

PENETRATIONS UP TO 12" WIDE;

REMOVE ENTIRE WIDTH OF ONE SINGLE

DECK PAN FOR A MAX 24" LENGTH.

ADJUST LOCATIONS AS REQUIRED TO

LIMIT TO ONE PAN.

12" MAX

W

2' - 6"

16 GA. SHEET (G60 GALVANIZED)

TYPICAL TOP AND BOTTOM OF

DECK. FASTENING SHOWN IS

TYPICAL TOP AND BOTTOM.

#12 TEK SCREWS

QUANTITY = (W) ROWS OF (3),

WHERE W = (WIDTH OF DECK

OPENING IN INCHES, NOT TO

EXCEED 12")

TY

P

/2

#12 TEK SCREWS @6"

PENETRATIONS NOT PERMITTED IN

(2) ADJACENT DECK PANS

#12 TEK SCREWS

QUANTITY = (W) ROWS OF (3),

WHERE W = (WIDTH OF DECK

OPENING IN INCHES, NOT TO

EXCEED 12")

PLAN VIEW

A A

SECTION A-A

16 GA. SHEET (G60 GALVANIZED).

SEE PLAN VIEW FOR FASTENING

NOTES:

1. 16 GA. SHEET SHOWN IS REQUIRED

ON TOP AND BOTTOM OF DECK.

SCREW FASTENING SHOWN IS TYPICAL

TOP AND BOTTOM.

2. FIELD LOCATE PENETRATIONS TO

ENSURE ONLY ONE DECK PAN IS

REMOVED BY A PENETRATION.

3. DECK MUST BE CLEANLY CUT BY

MECHANICAL METHODS (TORCH

CUTTING NOT PERMITTED).

4. OVERCUTTING BEYOND CORNERS OF

OPENING IS NOT PERMITTED.

3" 3"

M

A X.

/2

MAX.

1' - 0"

NOTE: PAINT EXPOSED STEEL

PLATE AND SCREWS, COLOR

TO MATCH EXISTING ROOF

DECK.

SEE MECHANICAL FOR GRILL

COVER AT OPENING. ATTACH

TO STEEL PLATE WITH

PERIMETER J MOLDING

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

O V

E R

A L L R

O O

F P

L A

N

.1

A

E A

S T

L E

R O

Y E

L E

M E

N T

A R

Y M

E C

H A

N

IC

A L

U P

G R

A D

E S

E a s t L e ro y M ic h ig a n

A T

H E

N S

A R

E A

S C

H O

O L S

D E

C E

M B

E R

3/32" = 1'-0"

OVERALL ROOF PLAN

EAST LEROY ELEMENTARY

UNIT

A

UNIT B UNIT C

KEY PLAN

SCALE: NO SCALE

KEYED NOTES - ARCHITECTURAL - CONSTRUCTION

1 PATCH EXISITNG GYPSUM BOARD VENEER WHERE REMOVED TO ACCOMMODATE NEW

PIPING INSTALLATION. PAINT ENTIRE WALL. COLOR TO BE SELECTED BY OWNER /

ARCHITECT

2 NEW PAINTED METAL VERTICAL PIPE COVER ENCLOSURE, REFER TO DETAIL 2 ON SHEET

A 101A. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW

3 NEW PAINTED METAL PIPE COVER ENCLOSURE, ABOVE. REFER TO DETAIL 1 ON A

101B. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW

4 INFILL DOOR TRANSOM W/ (1) LAYER OF 5/8" TYPE 'X' GYPSUM BOARD ON BOTH SIDES

TO REPLACE RATED GLASS. PAINT TO MATCH EXISTING WALL COLOR.

5 NEW CEILING MOUNTED PAINTED METAL PIPE ENCLOSURE

6 PAINTED STEEL PLATE AT RELIEF OPENING, COLOR TO MATCH EXISTING METAL DECK.

SEE LONG SPAN DECK DETAIL 1 ON SHEET A 102 AND SEE MECHANICAL FOR MORE

INFORMATION

7 REINSTALL EXISTING PIPE ENCLOSURE COVER.

9 NEW ROOF PENETRATION, SEE MECHANICAL AND TYPICAL LONG-SPAN ROOF DECK

PENETRATION WITHOUT SUPPORT FRAMING DETAIL 1 ON SHEET A 102 FOR MORE

INFORMATION. PATCH AND REPAIR ROOFING TO MATCH EXISTING ISULATION AND

MEMBRANE. PROVIDE NEW ROOF CURB FOR RELIEF HOOD. PROVIDE CRICKETS AS

NECESSARY TO DIRECT WATER TO EXISTING DRAINS.

11 NEW MECHANICAL FLU PENETRATION, PATCH AND SEAL ROOF TO MATCH EXISTING.

REFER TO MECHANICAL.

12 PROVIDE NEW 1 HOUR STUD AND GYPSUM BOARD ENCLOSTURE AT TRANSOM ABOVE

DOOR

13 PATCH AND PAINT WALL WHERE WALL MOUNTED UNIT IS REPLACED.

14 NEW WALL MOUNTED HORIZONTAL PAINTED METAL PIPE COVER ENCLOSURE, SEE DETAIL

3 ON A 101A

1 1/2" = 1'-0"

TYPICAL ROOF PENETRATION

1 1/2" = 1'-0"

TYPICAL EXISTING ROOF CURB

1 1/2" = 1'-0"

TYPICAL NEW ROOF CURB

3/4" = 1'-0"A 102

1 LONG-SPAN ROOF DECK PENETRATION WITHOUT SUPPORT FRAMING

LOBBY

MEN'S

TOILET

WOMEN'S

TOILET

BOILER ROOM

KITCHEN

TOILET

KITCHEN

STORAGE

STORAGE

MULTI-PURPOSE

ROOM

CLASSROOM

TOILET

TOILET

CLASSROOM

VESTIBULE

A 101A

A 101A

SIM

A 101A

SIM

UNIT

B

UNIT

A

UNIT A

UNIT C

GYPSUM BOARD

LAY-IN ACOUSTICAL TILE GRID

OR LIGHTING - REFER TO ELECTRICAL LIGHTING PLAN

MECHANICAL - REFER TO MECHANICAL SHEET METAL PLAN

KEY - REFLECTED CEILING

PAINTED BENT METAL ENCLOSURE

EXPOSED CEILING

GENERAL NOTES - REFLECTED CEILINGS

1. WHERE CEILING TILE IS LESS THAN 3" AT PERIMETER OF ROOM PROVIDE A CUT 2x4

TILE IN LIEU OF FULL 2x2 TILE AND SMALL PIECE OF TILE OR DOUBLE GRID - MATCH

2x2 FOR STYLE AND COLOR.

2. AT AREAS OF EXPOSED CEILING PAINT ALL STRUCTURE, DUCTWORK, PIPING, CONDUIT,

HANGERS ETC., COORDINATE WITH MECHANICAL, ELECTRICAL AND PLUMBING

SPECIFICATIONS. REFER TO THE REFLECTED CEILING PLANS FOR PAINT COLORS.

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

F

IR

S T

F L O

O R

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

U N

IT

A

.1

A

A

E A

S T

L E

R O

Y E

L E

M E

N T

A R

Y M

E C

H A

N

IC

A L

U P

G R

A D

E S

E a s t L e ro y M ic h ig a n

A T

H E

N S

A R

E A

S C

H O

O L S

D E

C E

M B

E R

1/8" = 1'-0"

REFLECTED CEILING PLAN - UNIT A

EAST LEROY ELEMENTARY

UNIT

A

UNIT B UNIT C

KEY PLAN

SCALE: NO SCALE

KEYED NOTES - ARCHITECTURAL - CONSTRUCTION

1 PATCH EXISITNG GYPSUM BOARD VENEER WHERE REMOVED TO ACCOMMODATE NEW

PIPING INSTALLATION. PAINT ENTIRE WALL. COLOR TO BE SELECTED BY OWNER /

ARCHITECT

2 NEW PAINTED METAL VERTICAL PIPE COVER ENCLOSURE, REFER TO DETAIL 2 ON SHEET

A 101A. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW

3 NEW PAINTED METAL PIPE COVER ENCLOSURE, ABOVE. REFER TO DETAIL 1 ON A

101B. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW

4 INFILL DOOR TRANSOM W/ (1) LAYER OF 5/8" TYPE 'X' GYPSUM BOARD ON BOTH SIDES

TO REPLACE RATED GLASS. PAINT TO MATCH EXISTING WALL COLOR.

5 NEW CEILING MOUNTED PAINTED METAL PIPE ENCLOSURE

6 PAINTED STEEL PLATE AT RELIEF OPENING, COLOR TO MATCH EXISTING METAL DECK.

SEE LONG SPAN DECK DETAIL 1 ON SHEET A 102 AND SEE MECHANICAL FOR MORE

INFORMATION

7 REINSTALL EXISTING PIPE ENCLOSURE COVER.

9 NEW ROOF PENETRATION, SEE MECHANICAL AND TYPICAL LONG-SPAN ROOF DECK

PENETRATION WITHOUT SUPPORT FRAMING DETAIL 1 ON SHEET A 102 FOR MORE

INFORMATION. PATCH AND REPAIR ROOFING TO MATCH EXISTING ISULATION AND

MEMBRANE. PROVIDE NEW ROOF CURB FOR RELIEF HOOD. PROVIDE CRICKETS AS

NECESSARY TO DIRECT WATER TO EXISTING DRAINS.

11 NEW MECHANICAL FLU PENETRATION, PATCH AND SEAL ROOF TO MATCH EXISTING.

REFER TO MECHANICAL.

12 PROVIDE NEW 1 HOUR STUD AND GYPSUM BOARD ENCLOSTURE AT TRANSOM ABOVE

DOOR

13 PATCH AND PAINT WALL WHERE WALL MOUNTED UNIT IS REPLACED.

14 NEW WALL MOUNTED HORIZONTAL PAINTED METAL PIPE COVER ENCLOSURE, SEE DETAIL

3 ON A 101A

T T

CORRIDOR

CLASSROOM

CLASSROOM

CLASSROOM

CUSTODIAN

TOILET

STAFF

CONFERENCE

GIRL'S TOILET

VAULT

OFFICE

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

152CLASSROOM

CLASSROOM

CONFERENCE

TOILET

152A

TOILET

153A

TOILET

154A CORRIDOR

58"

6 6 6

6 6 6

UNIT B UNIT C

UNIT

B

UNIT

A

UNIT A

UNIT C

2 2

2 2

CORRIDOR

GYPSUM BOARD

LAY-IN ACOUSTICAL TILE GRID

OR LIGHTING - REFER TO ELECTRICAL LIGHTING PLAN

MECHANICAL - REFER TO MECHANICAL SHEET METAL PLAN

KEY - REFLECTED CEILING

PAINTED BENT METAL ENCLOSURE

EXPOSED CEILING

GENERAL NOTES - REFLECTED CEILINGS

1. WHERE CEILING TILE IS LESS THAN 3" AT PERIMETER OF ROOM PROVIDE A CUT 2x4

TILE IN LIEU OF FULL 2x2 TILE AND SMALL PIECE OF TILE OR DOUBLE GRID - MATCH

2x2 FOR STYLE AND COLOR.

2. AT AREAS OF EXPOSED CEILING PAINT ALL STRUCTURE, DUCTWORK, PIPING, CONDUIT,

HANGERS ETC., COORDINATE WITH MECHANICAL, ELECTRICAL AND PLUMBING

SPECIFICATIONS. REFER TO THE REFLECTED CEILING PLANS FOR PAINT COLORS.

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

F

IR

S T

F L O

O R

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

U N

IT

B

.1

A

B

E A

S T

L E

R O

Y E

L E

M E

N T

A R

Y M

E C

H A

N

IC

A L

U P

G R

A D

E S

E a s t L e ro y M ic h ig a n

A T

H E

N S

A R

E A

S C

H O

O L S

D E

C E

M B

E R

1/8" = 1'-0"

REFLECTED CEILING PLAN - UNIT B

EAST LEROY ELEMENTARY

UNIT

A

UNIT B UNIT C

KEY PLAN

SCALE: NO SCALE

KEYED NOTES - ARCHITECTURAL - CONSTRUCTION

1 PATCH EXISITNG GYPSUM BOARD VENEER WHERE REMOVED TO ACCOMMODATE NEW

PIPING INSTALLATION. PAINT ENTIRE WALL. COLOR TO BE SELECTED BY OWNER /

ARCHITECT

2 NEW PAINTED METAL VERTICAL PIPE COVER ENCLOSURE, REFER TO DETAIL 2 ON SHEET

A 101A. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW

3 NEW PAINTED METAL PIPE COVER ENCLOSURE, ABOVE. REFER TO DETAIL 1 ON A

101B. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW

4 INFILL DOOR TRANSOM W/ (1) LAYER OF 5/8" TYPE 'X' GYPSUM BOARD ON BOTH SIDES

TO REPLACE RATED GLASS. PAINT TO MATCH EXISTING WALL COLOR.

5 NEW CEILING MOUNTED PAINTED METAL PIPE ENCLOSURE

6 PAINTED STEEL PLATE AT RELIEF OPENING, COLOR TO MATCH EXISTING METAL DECK.

SEE LONG SPAN DECK DETAIL 1 ON SHEET A 102 AND SEE MECHANICAL FOR MORE

INFORMATION

7 REINSTALL EXISTING PIPE ENCLOSURE COVER.

9 NEW ROOF PENETRATION, SEE MECHANICAL AND TYPICAL LONG-SPAN ROOF DECK

PENETRATION WITHOUT SUPPORT FRAMING DETAIL 1 ON SHEET A 102 FOR MORE

INFORMATION. PATCH AND REPAIR ROOFING TO MATCH EXISTING ISULATION AND

MEMBRANE. PROVIDE NEW ROOF CURB FOR RELIEF HOOD. PROVIDE CRICKETS AS

NECESSARY TO DIRECT WATER TO EXISTING DRAINS.

11 NEW MECHANICAL FLU PENETRATION, PATCH AND SEAL ROOF TO MATCH EXISTING.

REFER TO MECHANICAL.

12 PROVIDE NEW 1 HOUR STUD AND GYPSUM BOARD ENCLOSTURE AT TRANSOM ABOVE

DOOR

13 PATCH AND PAINT WALL WHERE WALL MOUNTED UNIT IS REPLACED.

14 NEW WALL MOUNTED HORIZONTAL PAINTED METAL PIPE COVER ENCLOSURE, SEE DETAIL

CORRIDOR

CUSTODIAN

TOILET

STAFF

CONFERENCE

GIRL'S TOILET

VAULT

OFFICE

132 VESTIBULE

LIBRARY

DATA

RELATED

ACTIVITIES

COUNSELOR

COMPUTER

LAB

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

BOY'S TOILET

HEALTH

TOILET

OFFICE

OFFICE

WORK ROOM

2 2

UNIT B UNIT C

UNIT

B

UNIT

A

UNIT A

UNIT C

2 2

GYPSUM BOARD

LAY-IN ACOUSTICAL TILE GRID

OR LIGHTING - REFER TO ELECTRICAL LIGHTING PLAN

MECHANICAL - REFER TO MECHANICAL SHEET METAL PLAN

KEY - REFLECTED CEILING

PAINTED BENT METAL ENCLOSURE

EXPOSED CEILING

GENERAL NOTES - REFLECTED CEILINGS

1. WHERE CEILING TILE IS LESS THAN 3" AT PERIMETER OF ROOM PROVIDE A CUT 2x4

TILE IN LIEU OF FULL 2x2 TILE AND SMALL PIECE OF TILE OR DOUBLE GRID - MATCH

2x2 FOR STYLE AND COLOR.

2. AT AREAS OF EXPOSED CEILING PAINT ALL STRUCTURE, DUCTWORK, PIPING, CONDUIT,

HANGERS ETC., COORDINATE WITH MECHANICAL, ELECTRICAL AND PLUMBING

SPECIFICATIONS. REFER TO THE REFLECTED CEILING PLANS FOR PAINT COLORS.

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

F

IR

S T

F L O

O R

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

U N

IT

C

.1

A

C

E A

S T

L E

R O

Y E

L E

M E

N T

A R

Y M

E C

H A

N

IC

A L

U P

G R

A…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .