This document contains construction drawings and plans for the mechanical upgrades at East Leroy Elementary School, located in East Leroy, Michigan. The project is being undertaken by Athens Area Schools, a school district in Calhoun County, Michigan.
The mechanical upgrades include replacing HVAC systems, boilers, piping, and other mechanical equipment throughout the school. The project involves work in three separate building units (Units A, B, and C), with a total finished project area of 33,774 square feet. The project must adhere to various building codes and standards. Bidders will need to review the detailed plans, specifications, and project details provided in the attachments. No specific bid due date or award date is mentioned, but the project is currently in the design and planning phase.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
DESIGN TEAM
ARCHITECT/ENGINEER
EAST LEROY ELEMENTARY MECHANICAL
UPGRADES
ATHENS AREA SCHOOLS
East Leroy, Michigan
CONSTRUCTION DOCUMENTS
C O
V E
R S
H E
E T
.1
G
E A
S T
L E
R O
Y E
L E
M E
N T
A R
Y M
E C
H A
N
IC
A L
U P
G R
A D
E S
E a s t L e ro y M ic h ig a n
A T
H E
N S
A R
E A
S C
H O
O L S
D E
C E
M B
E R
DRAWING INDEX
EAST LEROY ELEMENTARY SCHOOL
4320 K DRIVE SOUTH
EAST LEROY, MI 49051
242 E. KALAMAZOO AVE, SUITE 100
KALAMAZOO, MICHIGAN 49007
PHONE: 269.343.6133
FAX: 269.343.6633
CONSTRUCTION MANAGER
120 EAST PRAIRIE STREET, SUITE C
VICKSBURG, MI 49097
PHONE: 269.349.6133
FAX: 269.349.5936
BUILDING: 2015 MICHIGAN BUILDING CODE AND 2012 NFPA 101 LIFE SAFETY CODE
ENERGY: 2015 MICHIGAN ENERGY CODE
PLUMBING: 2018 MICHIGAN PLUMBING CODE
MECHANICAL: 2015 MICHIGAN MECHANICAL CODE
FUEL GAS: (IFGC) 2015 INTERNATIONAL FUEL GAS CODE
ELECTRICAL: 2017 NATIONAL ELECTRICAL CODE WITH MICHIGAN AMENDMENTS
BARRIER-FREE: 2015 MICHIGAN BUILDING CODE AND 2009 ICC & C A117.1
USE GROUP: E
CONSTRUCTION TYPE: IIB
AUTOMATIC SPRINKLERS: NONE
PROJECT AREA
TOTAL FINISHED PROJECT: 33,774 SQ. FT.
REFERENCED CODES
SITE ADDRESS
GENERAL
G 001 COVER SHEET
G 101 FIRST FLOOR CODE COMPLIANCE PLAN
ARCHITECTURAL GENERAL
AG 001 GENERAL ARCHITECTURAL NOTES, INTERIOR PARTITION TYPES AND
DEVICE ALIGNMENT GUIDELINES
ARCHITECTURAL DEMOLITION
AD 101A FIRST FLOOR DEMOLITION PLAN - UNIT A
AD 101B FIRST FLOOR DEMOLITION PLAN - UNIT B
AD 101C FIRST FLOOR DEMOLITION PLAN - UNIT C
AD 102 OVERALL ROOF DEMOLITION PLAN
ARCHITECTURAL
A 101A FIRST FLOOR PLAN - UNIT A
A 101B FIRST FLOOR PLAN - UNIT B
A 101C FIRST FLOOR PLAN - UNIT C
A 102 OVERALL ROOF PLAN
A 201A FIRST FLOOR REFLECTED CEILING PLAN - UNIT A
A 201B FIRST FLOOR REFLECTED CEILING PLAN - UNIT B
A 201C FIRST FLOOR REFLECTED CEILING PLAN - UNIT C
MECHANICAL & PLUMBING GENERAL
MG 001 MECHANICAL & PLUMBING GENERAL NOTES, ABBREVIATIONS, AND
SYMBOLS
MECHANICAL DEMOLITION
MD 101A FIRST FLOOR MECHANICAL DEMOLITION PLAN - UNIT A
MD 101B/C FIRST FLOOR MECHANICAL DEMOLITION PLAN - UNIT B & C
MECHANICAL
M 101A FIRST FLOOR MECHANICAL PLAN - UNIT A
M 101B/C FIRST FLOOR MECHANICAL PLAN - UNIT B & C
M 401 HVAC PIPING SCHEMATICS
M 501 MECHANICAL SCHEDULES AND DETAILS
M 502 MECHANICAL SCHEDULES AND DETAILS
M 601 MECHANICAL CONTROLS
M 602 MECHANICAL CONTROLS
ELECTRICAL - GENERAL
EG 001 ELECTRICAL SYMBOLS AND GENERAL NOTES
ELECTRICAL DEMOLITION
ED 101A FIRST FLOOR ELECTRICAL DEMOLITION PLAN - UNIT A
ED 101B FIRST FLOOR ELECTRICAL DEMOLITION PLAN - UNIT B
ED 101C FIRST FLOOR ELECTRICAL DEMOLITION PLAN - UNIT C
ELECTRICAL
E 101A FIRST FLOOR POWER PLAN - UNIT A
E 101B FIRST FLOOR POWER PLAN - UNIT B
E 101C FIRST FLOOR POWER PLAN - UNIT C
E 201A FIRST FLOOR LIGHTING PLAN - UNIT A
E 401 ELECTRICAL ONE-LINE DIAGRAM
E 411 ELECTRICAL DETAILS AND CONNECTION SCHEDULES
E 501 ELECTRICAL PANEL LOAD SCHEDULES
ISSUED FOR DATE
DN
EQ
EQ
EQ
EQ
EQ EQ
EQ
EQ
EQ EQ
EQ EQ EQ EQ EQ EQ
EQEQEQ
EQ
EQ
EQ
EQ EQ EQ EQ
EQ EQ
EQ EQ
EQ
EQ
EQ EQ EQEQ
J
J
EQ
EQ
WAPWAP
WAP
WAP WAPWAP
1. ALL PENETRATIONS THROUGH A FIRE OR SMOKE RATED PARTITION SHOULD BE
SEALED WITH AN APPROVED U.L. RATED PRODUCT.
2. THE TOPS OF ALL FIRE RATED PARTITIONS SHALL BE SEALED TO THE
CONTINUOUS STRUCTURE ABOVE WITH A U.L. RATED SYSTEM OR ASSEMBLY.
3. WOOD BLOCKING IN FIRE-RATED PARTITIONS SHALL BE NON-COMBUSTIBLE
TREATED WOOD.
4. REFER TO SPECIFICATION U.L. RATING INFORMATION.
5. FIRE-RATED WALLS ENDING INTO AN ACOUSTICAL DECK MUST HAVE THE FLUTES
FILLED, REFER TO 'TOP OF WALL DETAIL AT ACOUSTIC DECK' SHOWN ON THIS
SHEET.
• FOR MASONRY WALLS THE MASON SHALL FILL VOIDS AND FIRE SPRAY WITH UL LISTED
MATERIAL.
• FOR STUD WALLS USE FIRE SAFING AND FIRE CAULK.
CODE COMPLIANCE KEY
EGRESS SYMBOLS
EGRESS EXIT NUMBER FROM ROOM OR SPACE
MAXIMUM NUMBER OF OCCUPANTS PERMITTED
BY EGRESS WIDTH
ROOM OR SPACE EGRESS IS FROM
TRAVEL DISTANCE : 100'-0"
PERMITTED TRAVEL DISTANCE - 200'-0"
EXISTING TRAVEL DISTANCE
TO EGRESS DOOR
PERMITTED MAXIMUM TRAVEL
DISTANCE PER CONDITION
DIRECTION OF EGRESS
FIRE SAFETY SYMBOLS
FIRE-RATING KEY
XFE
XFEC
FE
FEC
EXISTING FIRE EXTINGUISHER
EXISTING FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
AED
AUTOMATED EXTERNAL DEFIBRILLATOR (AED)
RECESSED CABINET
DESIGNATION RATING PRIORITY
3 HOUR 1
2 HOUR 2
1 HOUR 3
SMOKE RESISTANT 4
COORDINATE ALL REQUIRED DAMPERS WITH MECHANICAL.
EGRESS ROOM
CORRIDOR
VESTIBULE
CLASSROOM
CLASSROOM
CLASSROOM
CUSTODIAN
TOILET
STAFF
CONFERENCE
LIBRARY
DATA
RELATED
ACTIVITIES
COUNSELOR
COMPUTER
LAB
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
HEALTH
TOILET
OFFICE
VAULT
OFFICE
CLASSROOM
CLASSROOM
CLASSROOM
LOBBY
MEN'S
TOILET
WOMEN'S
TOILET
BOILER ROOM
KITCHEN
TOILET
KITCHEN
STORAGE
STORAGE
MULTI-PURPOSE
ROOM
CLASSROOM
TOILET
TOILET
CLASSROOM
CLASSROOM
152CLASSROOM
CLASSROOM
CONFERENCE
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
F
IR
S T
F L O
O R
C O
D E
C O
M P
L
IA
N C
E P
L A
N
.1
G
E A
S T
L E
R O
Y E
L E
M E
N T
A R
Y M
E C
H A
N
IC
A L
U P
G R
A D
E S
E a s t L e ro y M ic h ig a n
A T
H E
N S
A R
E A
S C
H O
O L S
D E
C E
M B
E R
THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN
COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,
IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN
AN ACCURATE DRAWING
3/32" = 1'-0"
FIRST FLOOR CODE COMPLIANCE PLAN
THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN
COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,
IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN
AN ACCURATE DRAWING
EAST LEROY ELEMENTARY
UNIT
A
UNIT B UNIT C
KEY PLAN
SCALE: NO SCALE
HEAD
PLAN
SILL
STRUCTURE /
DECK ABOVE
DEFLECTION TRACK
SEALANT
SOUND BATTS IN
ALL WALLS -
UNLESS NOTED
OTHERWISE
FLOOR CONSTRUCTION
METAL STUDS @ 16" O.C. WITH 5/8"
GYPSUM BOARD BOTH SIDES;
(1 HOUR FIRE) U.L. ASSEMBLY U465
WHERE NOTED ON PLANS
METAL STUD WALL
HEAD
PLAN
SILL
STRUCTURE /
DECK ABOVE
DEFLECTION TRACK
SEALANT
SOUND BATTS (AT CHASE
WALLS ONLY) - UNLESS
NOTED OTHERWISE
FLOOR CONSTRUCTION
METAL STUDS @ 16" O.C. WITH 5/8"
GYPSUM BOARD ON ROOM SIDE - BRACE
WALL @ 4'-0" O.C. MAXIMUM.
METAL STUD CHASE WALL
OR FURRING
HEAD
PLAN
SILL
STRUCTURE /
DECK ABOVE
DEFLECTION TRACK
SEALANT
SOUND BATTS IN
ALL WALLS -
UNLESS NOTED
OTHERWISE
FLOOR CONSTRUCTION
METAL STUDS @ 16" O.C. WITH
5/8" TYPE "X" GYPSUM BOARD BOTH
SIDES TO DECK
STRUCTURAL METAL STUD WALL
HEAD
PLAN
SILL
STRUCTURE /
DECK ABOVE
DEFLECTION TRACK
SEALANT
FLOOR CONSTRUCTION
METAL CH STUDS @ 16" O.C. WITH 5/8"
TYPE "X" GYPSUM BOARD ON ROOM
SIDE AND 1" TYPE "X" GYPSUM BOARD
PANEL ON CHASE SIDE
HEAD
PLAN
SILL
STRUCTURE /
DECK ABOVE
DEFLECTION TRACK
SEALANT
SOUND BATTS IN
ALL WALLS -
UNLESS NOTED
OTHERWISE
FLOOR CONSTRUCTION
METAL STUDS @ 16" O.C. WITH (2)
LAYERS 5/8" TYPE "X" GYPSUM
BOARD BOTH SIDES
HEAD
PLAN
SILL
STRUCTURE /
DECK ABOVE
DEFLECTION TRACK
SEALANT
SOUND BATTS IN ALL
WALLS - UNLESS
NOTED OTHERWISE -
WEAVE IN-BETWEEN
STUDS
FLOOR CONSTRUCTION
6" TOP AND BOTTOM TRACK WITH 3 5/8"
METAL STUD FRAMING @ 16" O.C.
(OFFSET) WITH 5/8" GYPSUM BOARD BOTH
SIDES
HEAD
PLAN
SILL
STRUCTURE /
DECK ABOVE
BOND BEAM
SEALANT
FLOOR CONSTRUCTION
4" CONCRETE MASONRY UNITS
CMU WALL (1 AND 2 HOUR FIRE)
U.L. ASSEMBLY - U905
HEAD
PLAN
SILL
CMU WALL WITH FURRING CMU WALL WITH FURRING BOTH SIDES
C H A S E S
ID
E
R O
O M
S
ID
E
METAL STUD CHASE WALL (1 HOUR FIRE)
U.L. ASSEMBLY U415
METAL STUD WALL (2 HOUR FIRE)
U.L. ASSEMBLY U425
METAL STUD SOUND WALL
6" CONCRETE MASONRY UNITS
8" CONCRETE MASONRY UNITS
10" CONCRETE MASONRY UNITS
STRUCTURE /
DECK ABOVE
BOND BEAM
FLOOR CONSTRUCTION
STRUCTURE /
DECK ABOVE
BOND BEAM
FLOOR CONSTRUCTION
HEAD
PLAN
SILL
4" CONCRETE MASONRY UNITS WITH METAL
FURRING AND 5/8" GYPSUM BOARD
6" CONCRETE MASONRY UNITS METAL FURRING
AND 5/8" GYPSUM BOARD
8" CONCRETE MASONRY UNITS WITH METAL
FURRING AND 5/8" GYPSUM BOARD
10" CONCRETE MASONRY UNITS WITH METAL
FURRING AND 5/8" GYPSUM BOARD
4" CONCRETE MASONRY UNITS WITH METAL FURRING
AND 5/8" GYPSUM BOARD - BOTH SIDES
12" CONCRETE MASONRY UNITS 12" CONCRETE MASONRY UNITS WITH METAL
FURRING AND 5/8" GYPSUM BOARD
1X 2X 4X 5X
HEAD
PLAN
SILL
STRUCTURE /
DECK ABOVE
DEFLECTION TRACK
SEALANT
FLOOR CONSTRUCTION
METAL CH STUDS @ 16" O.C. WITH (2)
LAYERS 5/8" TYPE "X" GYPSUM BOARD
ON ROOM SIDE AND 1" TYPE "X"
GYPSUM BOARD PANEL ON CHASE SIDE
METAL STUD CHASE WALL (2 HOUR FIRE)
U.L. ASSEMBLY U438
6X 7X 8
6" CONCRETE MASONRY UNITS WITH METAL FURRING
AND 5/8" GYPSUM BOARD - BOTH SIDES
8" CONCRETE MASONRY UNITS WITH METAL FURRING
AND 5/8" GYPSUM BOARD - BOTH SIDES
10" CONCRETE MASONRY UNITS WITH METAL
FURRING AND 5/8" GYPSUM BOARD - BOTH SIDES
12" CONCRETE MASONRY UNITS WITH METAL
FURRING AND 5/8" GYPSUM BOARD - BOTH SIDES
9X
10X
11X
12X
13X
9XX
10XX
11XX
12XX
13XX
SEALANT SEALANT
METAL STUDS @ 16" O.C. WITH
1/2" RATED PLYWOOD ONE SIDE
AND 5/8" GYPSUM BOARD ON
BOTH SIDES.
3X
HEAD
PLAN
SILL
STRUCTURE /
DECK ABOVE
DEFLECTION TRACK
SEALANT
1/2" RATED
PLYWOOD
FLOOR CONSTRUCTION
METAL STUD WALL
WITH PLYWOOD BACKING
SOUND BATTS IN
ALL WALLS -
UNLESS NOTED
OTHERWISE
SOUND BATTS IN
ALL WALLS -
UNLESS NOTED
OTHERWISE
HEAD
PLAN
SILL
STRUCTURE /
DECK ABOVE
SEALANT
SOUND BATTS IN
ALL WALLS -
UNLESS NOTED
OTHERWISE
FLOOR CONSTRUCTION
WOOD STUDS @ 16" O.C. WITH 5/8"
GYPSUM BOARD BOTH SIDES;
(1 HOUR FIRE) U.L. ASSEMBLY U305
WHERE NOTED ON PLANS
WOOD STUD WALL
HEAD
PLAN
SILL
STRUCTURE /
DECK ABOVE
SEALANT
SOUND BATTS IN ALL
WALLS - UNLESS
NOTED OTHERWISE
FLOOR CONSTRUCTION
WOOD STUDS @ 16" O.C. WITH 5/8"
GYPSUM BOARD ON ROOM SIDE -
BRACE WALL @ 4'-0" O.C. MAXIMUM.
WOOD STUD CHASE WALL
C H A S E S
ID
E
R O
O M
S
ID
E
14X 15X
HEAD
PLAN
SILL
STRUCTURE /
DECK ABOVE
SEALANT
SOUND BATTS IN
ALL WALLS -
UNLESS NOTED
OTHERWISE
FLOOR CONSTRUCTION
WOOD STUDS @ 16" O.C. WITH (2)
LAYERS 5/8" TYPE "X" GYPSUM
BOARD BOTH SIDES
WOOD STUD WALL (2 HOUR FIRE)
U.L. ASSEMBLY U301
16X
SOUND BATTS IN
ALL WALLS -
UNLESS NOTED
OTHERWISE
INTERSECTION OF NON-RATED AT
1 HOUR RATED PARTITION
INTERSECTION OF NON-RATED AT 2 HOUR
RATED PARTITION - U.L. ASSEMBLY U425
1 HOUR RATED
PARTITION - REFER
TO PLAN
METAL STUD FRAMING
NON-RATED PARTITION - REFER TO PLAN
2 HOUR RATED
PARTITION -
REFER TO PLAN
METAL STUD FRAMING
NON-RATED PARTITION - REFER TO PLAN
INTERSECTION OF NON-RATED AT 2 HOUR
RATED PARTITION - U.L. ASSEMBLY U438
2 HOUR RATED
PARTITION -
REFER TO PLAN
CH STUD FRAMING
NON-RATED PARTITION - REFER TO PLAN
INTERSECTION OF
CONCRETE/MASONRY AT 1 HOUR
RATED PARTITION
CONCRETE OR MASONRY
WALL - REFER TO PLAN
1 HOUR RATED PARTITION -
REFER TO PLAN
METAL FURRING
GYPSUM BOARD CONTROL
JOINT NON-RATED PARTITION
• 1/2" MAXIMUM GAP FOR CONTROL JOINT
• 30'-0" MAX. BETWEEN CONTROL JOINTS
• REFER TO PARTITION TYPES FOR COMPLETE
DESCRIPTION OF COMPONENT PARTS
GYPSUM BOARD
METAL STUD FRAMING
BACKER
ROD AND
SEALANT
CONTROL JOINT
GYPSUM BOARD CONTROL
JOINT 1 HOUR RATED
PARTITION
• 1/2" MAXIMUM GAP FOR CONTROL JOINT
• 30'-0" MAX. BETWEEN CONTROL JOINTS
• REFER TO PARTITION TYPES FOR COMPLETE
DESCRIPTION OF COMPONENT PARTS
GYPSUM BOARD
METAL STUD FRAMING
(2) LAYERS TYPE
"X" GYPSUM
BOARD
CONTROL JOINT
GYPSUM BOARD CONTROL
JOINT 2 HOUR RATED
PARTITION
• 1/2" MAXIMUM GAP FOR CONTROL JOINT
• 30'-0" MAX. BETWEEN CONTROL JOINTS
• REFER TO PARTITION TYPES FOR COMPLETE
DESCRIPTION OF COMPONENT PARTS
METAL STUD FRAMING
(2) LAYERS TYPE "X"
GYPSUM BOARD
CONTROL JOINT
(2) LAYERS TYPE
"X" GYPSUM
BOARD
NOTE:
MOUNT EQUIPMENT AS SHOWN UNLESS SPECIFIED OTHERWISE.
MAX TWO DEVICES IN ONE HIGHER MOUNT
LOCATION AT LATCH SIDE OF DOOR, PROVIDE RFI
IF MORE DEVICES ARE NECESSARY. WHERE THERE
IS ONE DEVICE, CENTER OVER LOWER DEVICE. (TO
BE WITHIN ADA HEIGHT). (IF SWITCH CANNOT BE
LOCATED ON LATCH SIDE, LOCATE ONE DOOR
LEAF AWAY ON HINGE SIDE.)
DOOR
LOW DEVICES
RECEPTACLEVOICE/DATA
MASONRY COURSING
(WHERE APPLICABLE)
LIGHT SWITCH
F.A. AUDIO/VISUAL
ALIGNMENT NOTES
• ALIGN AND LOCATE CLOSE TOGETHER ANY DEVICES INSTALLED WITHIN 6' HORIZONTALLY.
• CENTER ALL DEVICES WHERE INDICATED ON COLUMN WRAP OR BUMP OUT; STACK AND ALIGN VERTICALLY.
• INSTALL DEVICES AT HEIGHTS INDICATED IN SYMBOL LEGEND UNLESS STACKING PER THIS DETAIL.
• WHERE HEIGHT IS SPECIFICALLY NOTED ON FLOOR PLANS, USE THAT MOUNTING HEIGHT
• CENTER ON DOORFRAME OR WHITEBOARDS ANY DEVICES INDICATED ABOVE.
O R L
A N D
IN
G
F R O
M F
LO
O
R
F R O
M F
LO
O
R O
R L
A N D
IN
G
6' - 0" MIN.
4" MAX
CAMERAS, CLOCKS, WALL
OCCUPANCY SENSORS
WHITE BOARD (WHERE APPLICABLE -
VERIFY WITH DETAILS/PLANS PROPER
INSTALL HEIGHT) CENTER ANY SINGLE
DEVICE WITH CENTER OF WHITE BOARD
ANY DEVICES
SHOWN OVER DOOR
TO BE CENTERED.
EQ EQ
EQ EQ
F R O
M F
LO
O
R O
R L
A N D
IN
G
SHORT THROW PROJECTOR
WHERE APPLICABLE
~12"
FA PULL STATION - HINGE SIDE
OF DOOR 1-LEAF AWAY WITHIN
5'-0" OF EXTERIOR OR STAIR
DOORS, WHEN WALL MOUNT
STROBES ARE ON PROJECT,
ALIGN ABOVE.
WHEN DEVICES ARE WITHIN DIMENSION, STACK
HIGH/LOW VERTICALLY AND GROUP DEVICES AT
SAME HEIGHT. UNLESS DEVICES IS PART OF
TECHNOLOGY DETAIL GROUPING OR SERVING A
FURNITURE GROUP.
CASEWORK, COORDINATE DEVICE BOTTOM
TO BE 2" OVER BACKSPLASH OR OVER
COUNTERTOP (IF NO BACKSPLASH). FOR
LARGE FORMAT TILE, ALIGN EDGE OF DEVICE
WITH HORIZONTAL GROUT LINE CLOSEST TO
COUNTERTOP.
COORDINATE OUTLET LOCATIONS WITH
GROUT LINES, EDGE OF DEVICE ON GROUT
LINE IF POSSIBLE. COORDINATE WITH
INTERIOR DESIGN DRAWINGS.
TYPICAL COLUMN
ENCLOSURE, CHASE OR
BUMP-OUT WITH DEVICES
INDICATED IN PLANS.
EQ EQ
EQEQEQEQ
THERMOSTAT,
SENSORS OR AV
CONTROLLER, CARD
READER, ETC.
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
G E
N E
R A
L A
R C
H
IT
E C
T U
R A
L N
O T
E S
IN
T E
R
IO
R P
A R
T
IT
IO
N
T Y
P E
S A
N D
D E
V
IC
E A
L
IG
N M
E N
T G
U
ID
E L
IN
E S
.1
A G
E A
S T
L E
R O
Y E
L E
M E
N T
A R
Y M
E C
H A
N
IC
A L
U P
G R
A D
E S
E a s t L e ro y M ic h ig a n
A T
H E
N S
A R
E A
S C
H O
O L S
D E
C E
M B
E R
GENERAL NOTES - ARCHITECTURAL - NEW CONSTRUCTION
1 THE OWNER RESERVES THE RIGHT TO REMOVE ANY ITEM FROM THE PROJECT PRIOR TO
COMMENCEMENT OF CONTRACTED DEMOLITION WORK.
2 ALL EXISTING CONDITIONS SHOULD BE FIELD VERIFIED BEFORE WORK BEGINS.
3 DIMENSIONS GIVEN ARE ACTUAL AND ARE TO THE FACE OF MASONRY UNITS OR TO THE
FACE OF STUD FRAMING, UNLESS NOTED OTHERWISE.
4 DETAILS SHOWN ILLUSTRATE DESIGN INTENT, NOT ALL POSSIBLE CONDITIONS. FOR
CONDITIONS NOT SHOWN, USE DETAILS CLOSEST TO CONDITION IN QUESTION.
5 EXTEND ALL INTERIOR WALL PARTITIONS FROM FLOOR TO STRUCTURE/DECK ABOVE
UNLESS NOTED OR DETAILED OTHERWISE.
6 WITHIN BUILDING INTERIOR PROVIDE BULLNOSE BLOCK IN CMU WALL ASSEMBLIES AT
ALL EXPOSED OUTSIDE CORNERS, INCLUDING WINDOW AND DOOR JAMBS, UNLESS
NOTES OR DETAILED OTHERWISE. PROVIDE SQUARE CORNERS AT ALL LOCATIONS
FINISHED WITH WALL TILE, REFER TO FINISH PLANS (I100 SHEETS) FOR LOCATIONS.
7 TOOTH-IN MASONRY AT NEW OPENINGS IN EXISTING WALLS.
8 TOOTH-IN NEW MASONRY INFILL INTO EXISTING OPENINGS AT ALL BULLNOSE BLOCK
LOCATIONS.
9 STUD WALLS SPANNING OVER 12'-0" IN HEIGHT SHALL BE A MINIMUM OF 20 GAGE.
10 STUD WALL SUPPORTING WALL CABINETS SHALL BE A MINIMUM OF 20 GAGE.
11 DOORS ARE TO BE 4" FROM CORNER OF ROOM, UNLESS NOTED OR DIMENSIONED
OTHERWISE.
12 FIRESTOP ALL INTERCONNECTIONS BETWEEN VERTICAL AND HORIZONTAL SPACES AND
CONCEALED WALL SPACES AT CEILING, FLOOR AND ROOF LEVELS.
13 FIRESEAL ALL PENETRATIONS, SUCH AS, PIPES, DUCTS, CONDUITS, ETC. THROUGH FIRE
AND/OR SMOKE RATED ASSEMBLIES.
14 FOR CONTROL JOINT (C.J.) LOCATIONS REFER TO EXTERIOR ELEVATIONS AND/OR FLOOR
PLANS.
15 PAINT ALL ELECTRICAL PANEL COVERS AND ACCESS PANELS TO MATCH ADJACENT
FINISHES. USING OIL-BASED PAINT, NOT LATEX WALL PAINT.
16 PROVIDE WOOD BLOCKING IN WALLS THAT REQUIRE WALL MOUNTED EQUIPMENT OR
ACCESSORIES. COORDINATE WITH EQUIPMENT OR ACCESSORY MANUFACTURER.
17 ROVIDE ALL ASSOCIATED CURBS FOR ROOF TOP EQUIPMENT AND MECHANICAL ROOF
TOP UNITS. LARGE VOIDS BELOW THE AIR HANDLING UNITS SHALL BE FILLED WITH
INSULATION AS SPECIFIED FOR NOISE CONTROL.
18 ALL EXISTING ROOF TOP PENETRATIONS BEING REMOVED REQUIRE ROOF PATCHING TO
MATCH EXISTING ADJACENT.
GENERAL NOTES - ARCHITECTURAL - DEMOLITION
1 CONTRACTORS ARE REQUIRED TO INSPECT/REVIEW THE EXISTING BUILDING PRIOR TO
RELATED DEMOLITION WORK. UNLESS NOTED OTHERWISE, REMOVAL OF ANY WALL,
FLOOR OR CEILING INCLUDES ALL GENERAL MECHANICAL AND ELECTRICAL ITEMS WHICH
ARE A PART OF, OR ATTACHED TO IT.
2 CONTRACTOR SHALL VERIFY ALL EXISTING JOB SITE CONDITIONS AND DIMENSIONS AND
BE RESPONSIBLE FOR THE SAME ADVISE CONSTRUCTION MANAGER OF ANY AND ALL
DISCREPANCIES.
3 PATCH FLOORS, WALLS AND CEILINGS DAMAGED DURING CONSTRUCTION AND
DEMOLITION AS REQUIRED. FINISH TO MATCH EXISTING.
4 ACCOMMODATE NEW CONSTRUCTION IF NOT INDICATED.
5 PROTECT ALL EXISTING FINISHES THROUGHOUT PROJECT.
6 REFER TO DEMOLITION ELEVATIONS, SECTIONS AND DETAILS FOR ADDITIONAL
INFORMATION.
7 REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL PLANS FOR
ADDITIONAL DEMOLITION NOTES.
8 SALVAGE ALL UNISTRUT AND PROTECT FOR RE-USE IN NEW CONSTRUCTION, IF
REQUIRED.
9 AT LOCATIONS OF REMOVED WALLS, ALL ASSOCIATED ITEMS ATTACHED TO THE WALL
ARE TO BE REMOVED. SUCH AS: DOORS, WINDOWS, FRAMES, MARKERBOARDS,
TACKBOARDS, TACK STRIPS, ETC.
SCALE: NONE
FIRE RATED WALL PLAN DETAILS
3/4" = 1'-0"
INTERIOR PARTITION TYPES
GENERAL NOTES - ARCHITECTURAL - PARTITIONS
1 NOT ALL WALL TYPES MAY BE USED ON PROJECT.
2 REFER TO CODE COMPLIANCE PLANS FOR LOCATIONS OF SMOKE AND FIRE-RATED
PARTITIONS.
3 ALL PARTITIONS EXTEND TO BOTTOM OF STRUCTURE, UNLESS NOTED OTHERWISE.
4 LINE OF STRUCTURE/DECK AS SHOWN AT THE HEAD CONDITION OF EACH PARTITION
TYPE IS DIAGRAMMATIC ONLY AND DOES NOT INDICATE EXACT CONSTRUCTION
CONDITIONS. TERMINATE RATED PARTITIONS AT UNDERSIDE OF STRUCTURAL DECK TO
MAINTAIN RATING. PROVIDE APPROPRIATE FRAMING AND GYPSUM BOARD TO OFFSET
AROUND STRUCTURE OR OTHER OBSTRUCTIONS, SUCH AS PIPING OR DUCTWORK.
5 PARTITIONS MAY TERMINATE AT STRUCTURAL MEMBERS WITH A RATING GREATER THAN
OR EQUAL THE PARTITION, PROVIDED THAT RATING IS CONTINUOUS TO STRUCTURAL
DECK ABOVE.
6 NON-RATED PARTITIONS THAT EXTEND TO STRUCTURE SHALL TERMINATE AT UNDERSIDE
OF STRUCTURAL DECK TO MAINTAIN A CONTINUOUS PLANE OF GYPSUM BOARD AS A
NOISE, SMOKE OR OTHER TYPE OF BARRIER.
7 ALL PARTITIONS EXTENDING TO STRUCTURE ABOVE SHALL TERMINATE WITH DEFLECTION
TRACK - SEE TYPICAL DETAILS ON THIS SHEET.
8 ALL GYPSUM BOARD PARTITIONS NOT EXTENDING TO THE STRUCTURE MUST BE
BRACED.
9 UL DESIGN NUMBERS REFER TO THE FIRE RESISTANCE DIRECTORY; UNDERWRITERS
LABORATORY, LATEST EDITION.
10 MISCELLANEOUS NON-RATED CHASES TO BE 5/8" GYPSUM BOARD ON 3 5/8" METAL
STUD FRAMING AT 16" O.C., UNLESS NOTED OTHERWISE.
11 MISCELLANEOUS FURRING AROUND COLUMNS TO BE 5/8" GYPSUM BOARD ON 11/2"
STUDS, UNLESS NOTED OTHERWISE.
12 FIRE-RATED PARTITIONS TO HAVE FIRE-STOPPING SEALANTS AT HEAD, SILL JUNCTURE
WITH DISSIMILAR MATERIALS, ETC. AND AROUND ALL PENETRATIONS AND OPENINGS.
13 CONSTRUCT ALL PARTITIONS WITH SOUND ATTENUATION BATTS WITH THE FOLLOWING
SOUND BATT THICKNESS: 2 1/2" OR LESS METAL STUD - 1 1/2" THICKNESS, 3 5/8" OR
LARGER METAL STUD - 3" THICKNESS. UNLESS NOTED OTHERWISE.
PARTITION STUD KEY - METAL, CH, AND WOOD
A GYPSUM BOARD DIRECT APPLIED TO CMU
B 7/8"
C 1 1/2"
D 1 5/8"
E 2 1/2"
F 3 1/2"
G 3 5/8"
H 4
J 5 1/2"
K 6"
L 8"
M 10"
N 12"
P OPEN
Q OPEN
R 2 1/2"
S 4"
T 6"
U 2"x4"
V 2"x6"
W 2"x8"
METAL STUD/FURRING
DESIGNATION SIZE
METAL STUD/FURRING
DESIGNATION SIZE
METAL STUD/FURRING
DESIGNATION SIZE
PARTITION TYPE TAG (REFER TO FLOOR PLANS)
1X
PARTITION TYPE NUMBER STUD SIZE DESIGATION
FIRE RATING, IF REQUIRED
1X
LIST OF ABBREVIATIONS
ACP ACOUSTICAL PANEL CEILING
AFF ABOVE FINISH FLOOR
ALUM ALUMINUM
ANOD ANODIZED
CFMF COLD FORMED METAL FRAMING
CMU CONCRETE MASONRY UNIT
CONC CONCRETE
DCMU DECOTATIVE CONCRETE MASONRY UNIT
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FRT FIRE RESISTANT TREATED
FV FIELD VERIFY
GYP BD GYPSUM BOARD
HM HOLLOW METAL
LVL LAMINATED VENEER LUMBER
MCM METAL COMPOSITE MATERIAL WALL PANEL
OC ON CENTER
PT PRESERVATIVE TREATED
PNT PAINT
SS STAINLESS STEEL
SSM SOLID SURFACE MATERIAL
TYP TYPICAL
VIF VERIFY IN FEILD
WD WOOD
12" = 1'-0"
DEVICE ALIGNMENT GUIDELINES
T
T
T
EQ
EQ
EQ
EQ
EQ EQ EQ
EQ
EQ
OFFICE
LOBBY
MEN'S
TOILET
WOMEN'S
TOILET
BOILER ROOM
KITCHEN
TOILET
KITCHEN
STORAGE
STORAGE
MULTI-PURPOSE
ROOM
CLASSROOM
TOILET
TOILET
CLASSROOM
VIF
7' - 0" 2' - 0"
V
IF
VIF
7' - 0" 2' - 0"
V
IF
/2
UNIT
B
UNIT
A
UNIT A
UNIT C
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
F
IR
S T
F L O
O R
D E
M O
L
IT
IO
N
P L A
N
U N
IT
A 2 .1
A D
A
E A
S T
L E
R O
Y E
L E
M E
N T
A R
Y M
E C
H A
N
IC
A L
U P
G R
A D
E S
E a s t L e ro y M ic h ig a n
A T
H E
N S
A R
E A
S C
H O
O L S
D E
C E
M B
E R
THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN
COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,
IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN
AN ACCURATE DRAWING
KEYED NOTES - ARCHITECTURAL - DEMOLITION
1 REMOVE CEILING TILES AS NEEDED TO ACCOMMODATE NEW MECHANICAL PIPING AND
ELECTRICAL CONDUIT INSTALLATION. REFER TO MEP DRAWINGS FOR MORE
INFORMATION
2 REMOVE AND DISPOSE OF EXISTING DOOR AND FRAME. PREP OPENING FOR NEW
DOOR AND FRAME.
3 REMOVE EXISTING HORIZONTAL UNIT VENT AND PREP FOR NEW. REFER TO
MECHANICAL FOR MORE INFORMATION
4 REMOVE AND DISPOSE OF EXISITNG GLASS TRANSOM OVER DOOR TO ACCOMMODATE
NEW PIPING INSTALLATION. PREP OPENING FOR NEW 1 HOUR RATED INFILL
5 CUT NEW 12" X 24" OPENING IN EXISTING STEEL DECK. REFER TO LONG SPAN DECK
DETAIL 1 ON A 102 AND MECHANICAL FOR MORE INFORMATION
6 REMOVE PORTION OF EXISTING BULLETIN BOARD TO ACCOMMODATE NEW VERTICAL
PIPE ENCLOSURE
7 REMOVE PORTION OF EXISTING BOOKCASE TO ACCOMMODATE NEW CEILING MOUNTED
PIPE ENCLOSURE. REMOVE ONLY ENOUGH TO ACCOMMODATE NEW PIPE COVER
8 REMOVE AND SALVAGE EXISTING PIPE ENCLOSURE TO ACCOMMODATE NEW PIPING
INSTALLATION. REINSTALL AFTER COMPLETION. SEE MECHANICAL FOR MORE
INFORMATION.
9 REMOVE EXISTING HORIZONTAL UNIT VENT AND PREP FOR NEW. REFER TO
MECHANICAL FOR MORE INFORMATION
10 REMOVE PORTION OF EXISTING ROOFING DOWN TO EXISTING DECK TO ACCOMMODATE
NEW RELIEF HOOD INSTALLATION. COORDINATE WITH MECHANICAL FOR SIZE AND
LOCATION. NOTE, AT STRUCTURAL METAL DECK, SEE DETAIL TO ADD STEEL PLATE AND
COORDINATE WITH MECHANICAL FOR INSTALLATION OF NEW RELIEF HOOD CURB.
11 REMOVE PORTION OF EXISTING GYPSUM BOARD FINISH TO ACCOMMODATE NEW
PIPING INSTALLATION WITHIN EXISTNG STUD WALL FOR NEW MECHANICAL UNIT. REFER
TO MECHANICAL AND ELECTRICAL FOR MORE INFORMATION.
12 SHIFT EXISTING TOILET PAPER DISPENSER TO ALLOW INSTALLATION OF NEW HYDRONIC
PIPING AND ENCLOSURE.
13 REMOVE EXISTING ENCLOSURE AT REFRIGERANT LINES. REFRIGERANT LINES TO REMAIN
AND BE ENCLOSED WITHIN NEW VERTICAL ENCLOSURE
14 REMOVE AND SALVAGE EXISTING WINDOW SHADE DEVICE TO ACCOMMODATE PIPE AND
VERTICAL ENCLOSURE INSTALLATION
1/8" = 1'-0"
FIRST FLOOR DEMOLITION - UNIT A
EAST LEROY ELEMENTARY
UNIT
A
UNIT B UNIT C
KEY PLAN
TT
TTT
TT
T
T T
T
T T
T
T
EQ EQ EQ
EQ
EQ EQ
EQ EQ EQ
WAPWAP
WAP
WAP WAPWAP
CORRIDOR
CLASSROOM
CLASSROOM
CLASSROOM
CUSTODIAN
TOILET
STAFF
CONFERENCE
VAULT
OFFICE
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
152CLASSROOM
CLASSROOM
CONFERENCE
3 3
3 3 3
1 1
3 3
5 5
4' - 0" 2' - 0"
V
IF
4' - 0"
2' - 0"
V
IF
/2
4' - 0" 2' - 0"
V
IF
4' - 0" 2' - 0"
V
IF
4' - 0" 2' - 0" 1
V
IF
4' - 0" 2' - 0" 1
V
IF
SEE IMAGE
ONE THIS
SHEET
SEE IMAGE
TWO THIS
SHEET
SEE IMAGE
ONE THIS
SHEET
(SIMILAR)
UNIT B UNIT C
UNIT
B
UNIT
A
UNIT A
UNIT C
CORRIDOR
CORRIDOR
CORRIDOR
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
F
IR
S T
F L O
O R
D E
M O
L
IT
IO
N
P L A
N
U N
IT
B
.1
A D
B
E A
S T
L E
R O
Y E
L E
M E
N T
A R
Y M
E C
H A
N
IC
A L
U P
G R
A D
E S
E a s t L e ro y M ic h ig a n
A T
H E
N S
A R
E A
S C
H O
O L S
D E
C E
M B
E R
1/8" = 1'-0"
FIRST FLOOR DEMOLITION - UNIT B
THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN
COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,
IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN
AN ACCURATE DRAWING
KEYED NOTES - ARCHITECTURAL - DEMOLITION
1 REMOVE CEILING TILES AS NEEDED TO ACCOMMODATE NEW MECHANICAL PIPING AND
ELECTRICAL CONDUIT INSTALLATION. REFER TO MEP DRAWINGS FOR MORE
INFORMATION
2 REMOVE AND DISPOSE OF EXISTING DOOR AND FRAME. PREP OPENING FOR NEW
DOOR AND FRAME.
3 REMOVE EXISTING HORIZONTAL UNIT VENT AND PREP FOR NEW. REFER TO
MECHANICAL FOR MORE INFORMATION
4 REMOVE AND DISPOSE OF EXISITNG GLASS TRANSOM OVER DOOR TO ACCOMMODATE
NEW PIPING INSTALLATION. PREP OPENING FOR NEW 1 HOUR RATED INFILL
5 CUT NEW 12" X 24" OPENING IN EXISTING STEEL DECK. REFER TO LONG SPAN DECK
DETAIL 1 ON A 102 AND MECHANICAL FOR MORE INFORMATION
6 REMOVE PORTION OF EXISTING BULLETIN BOARD TO ACCOMMODATE NEW VERTICAL
PIPE ENCLOSURE
7 REMOVE PORTION OF EXISTING BOOKCASE TO ACCOMMODATE NEW CEILING MOUNTED
PIPE ENCLOSURE. REMOVE ONLY ENOUGH TO ACCOMMODATE NEW PIPE COVER
8 REMOVE AND SALVAGE EXISTING PIPE ENCLOSURE TO ACCOMMODATE NEW PIPING
INSTALLATION. REINSTALL AFTER COMPLETION. SEE MECHANICAL FOR MORE
INFORMATION.
9 REMOVE EXISTING HORIZONTAL UNIT VENT AND PREP FOR NEW. REFER TO
MECHANICAL FOR MORE INFORMATION
10 REMOVE PORTION OF EXISTING ROOFING DOWN TO EXISTING DECK TO ACCOMMODATE
NEW RELIEF HOOD INSTALLATION. COORDINATE WITH MECHANICAL FOR SIZE AND
LOCATION. NOTE, AT STRUCTURAL METAL DECK, SEE DETAIL TO ADD STEEL PLATE AND
COORDINATE WITH MECHANICAL FOR INSTALLATION OF NEW RELIEF HOOD CURB.
11 REMOVE PORTION OF EXISTING GYPSUM BOARD FINISH TO ACCOMMODATE NEW
PIPING INSTALLATION WITHIN EXISTNG STUD WALL FOR NEW MECHANICAL UNIT. REFER
TO MECHANICAL AND ELECTRICAL FOR MORE INFORMATION.
12 SHIFT EXISTING TOILET PAPER DISPENSER TO ALLOW INSTALLATION OF NEW HYDRONIC
PIPING AND ENCLOSURE.
13 REMOVE EXISTING ENCLOSURE AT REFRIGERANT LINES. REFRIGERANT LINES TO REMAIN
AND BE ENCLOSED WITHIN NEW VERTICAL ENCLOSURE
14 REMOVE AND SALVAGE EXISTING WINDOW SHADE DEVICE TO ACCOMMODATE PIPE AND
VERTICAL ENCLOSURE INSTALLATION
EAST LEROY ELEMENTARY
UNIT
A
UNIT B UNIT C
KEY PLAN
SCALE: NO SCALE
IMAGE ONE IMAGE TWO
REMOVE EXISTING GLASS TRANSOM
AND PREP FOR NEW 1-HOUR
ENCLOSURE
REMOVE AND SALVAGE EXISTING
PIPE ENCLOSURE. SAVE FOR RE-
INSTALLATION
T T T
T
T
T
T
T
T
T
T
T
T
T
EQ
EQ EQ EQ EQ
EQEQEQ
CORRIDOR
CUSTODIAN
TOILET
STAFF
CONFERENCE
VAULT
OFFICE
132 VESTIBULE
LIBRARY
DATA
RELATED
ACTIVITIES
COUNSELOR
COMPUTER
LAB
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
HEALTH
TOILET
OFFICE
3 3
3 3 3 3
3 3 3
SEE IMAGE
ONE THIS
SHEET
SEE IMAGE
THREE THIS
SHEET
SEE IMAGE
TWO THIS
SHEET
SEE IMAGE
FOUR THIS
SHEET
SEE IMAGE
FIVE THIS
SHEET
SEE IMAGE
SIX THIS
SHEET
2' - 0" 4' - 0"
V
IF
2' - 0" 4' - 0"
V
IF
6' - 0" 2' - 0"
V
IF
EQ. 2' - 0" EQ.
V
IF
2' - 0" 3' - 4 1/2"
V
IF
2' - 0" 4' - 0"
V
IF
2' - 0" 4' - 0"
V
IF
6' - 0" 2' - 0"
" V
IF
UNIT B UNIT C
UNIT A
UNIT C
SEE IMAGE
SEVEN THIS
SHEET
13 14
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
F
IR
S T
F L O
O R
D E
M O
L
IT
IO
N
P L A
N
U N
IT
C
.1
A D
C
E A
S T
L E
R O
Y E
L E
M E
N T
A R
Y M
E C
H A
N
IC
A L
U P
G R
A D
E S
E a s t L e ro y M ic h ig a n
A T
H E
N S
A R
E A
S C
H O
O L S
D E
C E
M B
E R
1/8" = 1'-0"
FIRST FLOOR DEMOLITION - UNIT C
THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN
COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,
IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN
AN ACCURATE DRAWING
KEYED NOTES - ARCHITECTURAL - DEMOLITION
1 REMOVE CEILING TILES AS NEEDED TO ACCOMMODATE NEW MECHANICAL PIPING AND
ELECTRICAL CONDUIT INSTALLATION. REFER TO MEP DRAWINGS FOR MORE
INFORMATION
2 REMOVE AND DISPOSE OF EXISTING DOOR AND FRAME. PREP OPENING FOR NEW
DOOR AND FRAME.
3 REMOVE EXISTING HORIZONTAL UNIT VENT AND PREP FOR NEW. REFER TO
MECHANICAL FOR MORE INFORMATION
4 REMOVE AND DISPOSE OF EXISITNG GLASS TRANSOM OVER DOOR TO ACCOMMODATE
NEW PIPING INSTALLATION. PREP OPENING FOR NEW 1 HOUR RATED INFILL
5 CUT NEW 12" X 24" OPENING IN EXISTING STEEL DECK. REFER TO LONG SPAN DECK
DETAIL 1 ON A 102 AND MECHANICAL FOR MORE INFORMATION
6 REMOVE PORTION OF EXISTING BULLETIN BOARD TO ACCOMMODATE NEW VERTICAL
PIPE ENCLOSURE
7 REMOVE PORTION OF EXISTING BOOKCASE TO ACCOMMODATE NEW CEILING MOUNTED
PIPE ENCLOSURE. REMOVE ONLY ENOUGH TO ACCOMMODATE NEW PIPE COVER
8 REMOVE AND SALVAGE EXISTING PIPE ENCLOSURE TO ACCOMMODATE NEW PIPING
INSTALLATION. REINSTALL AFTER COMPLETION. SEE MECHANICAL FOR MORE
INFORMATION.
9 REMOVE EXISTING HORIZONTAL UNIT VENT AND PREP FOR NEW. REFER TO
MECHANICAL FOR MORE INFORMATION
10 REMOVE PORTION OF EXISTING ROOFING DOWN TO EXISTING DECK TO ACCOMMODATE
NEW RELIEF HOOD INSTALLATION. COORDINATE WITH MECHANICAL FOR SIZE AND
LOCATION. NOTE, AT STRUCTURAL METAL DECK, SEE DETAIL TO ADD STEEL PLATE AND
COORDINATE WITH MECHANICAL FOR INSTALLATION OF NEW RELIEF HOOD CURB.
11 REMOVE PORTION OF EXISTING GYPSUM BOARD FINISH TO ACCOMMODATE NEW
PIPING INSTALLATION WITHIN EXISTNG STUD WALL FOR NEW MECHANICAL UNIT. REFER
TO MECHANICAL AND ELECTRICAL FOR MORE INFORMATION.
12 SHIFT EXISTING TOILET PAPER DISPENSER TO ALLOW INSTALLATION OF NEW HYDRONIC
PIPING AND ENCLOSURE.
13 REMOVE EXISTING ENCLOSURE AT REFRIGERANT LINES. REFRIGERANT LINES TO REMAIN
AND BE ENCLOSED WITHIN NEW VERTICAL ENCLOSURE
14 REMOVE AND SALVAGE EXISTING WINDOW SHADE DEVICE TO ACCOMMODATE PIPE AND
VERTICAL ENCLOSURE INSTALLATION
EAST LEROY ELEMENTARY
UNIT
A
UNIT B UNIT C
KEY PLAN
SCALE: NO SCALE
IMAGE ONE IMAGE TWO IMAGE THREE
IMAGE FOUR IMAGE FIVE IMAGE SIX
REMOVE SECTION OF BULLETIN
BOARD TO ACCOMMODATE NEW
HYDRONIC PIPING INSTALLATION
AND BENT METAL SHROUD
REMOVE 12" WIDE SECTION
FROM BULLETIN BOARD TO
ACCOMMODATE NEW PIPING AND
SHROUD INSTALLATION
REMOVE PORTION OF EXISTING
SHELVING TO ACCOMMODATE
NEW PIPING INSTALLATION
REMOVE EXISTING ENCLOSURE.
REFRIGERANT LINES TO REMAIN
AND BE CONCEALED WITHIN NEW
VERTICAL ENCLOSURE
COORDINATE W/ NEW PIPING
INSTALLATION
COORDINATE W/ NEW PIPING
AND METAL SHROUD INSTALLATION
IMAGE SEVEN
REMOVE EXISTING SHELVING UNIT
TO ACCOMMODATE NEW VERTICAL
PIPE ENCLOSURE
IMAGE EIGHT
RELOCATE EXISTING SHELVING UNIT
TO ACCOMMODATE NEW VERTICAL
PIPE ENCLOSURE
TT
T
T T
T T T
TTT
T
T
T
T
T
T
T
T
T
T
T T
T
T
T
T
T
EQ EQ EQ
EQ
EQ
EQ EQ
EQ EQ EQ EQ EQ EQ EQ
EQEQEQ
EQ
EQ
EQ
EQ
EQ EQ EQ
EQ
EQ
WAPWAP
WAP
WAP WAPWAP
10 10
10 10
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
O V
E R
A L L R
O O
F D
E M
O L
IT
IO
N
P L A
N
.1
A D
E A
S T
L E
R O
Y E
L E
M E
N T
A R
Y M
E C
H A
N
IC
A L
U P
G R
A D
E S
E a s t L e ro y M ic h ig a n
A T
H E
N S
A R
E A
S C
H O
O L S
D E
C E
M B
E R
THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN
COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,
IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN
AN ACCURATE DRAWING
KEYED NOTES - ARCHITECTURAL - DEMOLITION
1 REMOVE CEILING TILES AS NEEDED TO ACCOMMODATE NEW MECHANICAL PIPING AND
ELECTRICAL CONDUIT INSTALLATION. REFER TO MEP DRAWINGS FOR MORE
INFORMATION
2 REMOVE AND DISPOSE OF EXISTING DOOR AND FRAME. PREP OPENING FOR NEW
DOOR AND FRAME.
3 REMOVE EXISTING HORIZONTAL UNIT VENT AND PREP FOR NEW. REFER TO
MECHANICAL FOR MORE INFORMATION
4 REMOVE AND DISPOSE OF EXISITNG GLASS TRANSOM OVER DOOR TO ACCOMMODATE
NEW PIPING INSTALLATION. PREP OPENING FOR NEW 1 HOUR RATED INFILL
5 CUT NEW 12" X 24" OPENING IN EXISTING STEEL DECK. REFER TO LONG SPAN DECK
DETAIL 1 ON A 102 AND MECHANICAL FOR MORE INFORMATION
6 REMOVE PORTION OF EXISTING BULLETIN BOARD TO ACCOMMODATE NEW VERTICAL
PIPE ENCLOSURE
7 REMOVE PORTION OF EXISTING BOOKCASE TO ACCOMMODATE NEW CEILING MOUNTED
PIPE ENCLOSURE. REMOVE ONLY ENOUGH TO ACCOMMODATE NEW PIPE COVER
8 REMOVE AND SALVAGE EXISTING PIPE ENCLOSURE TO ACCOMMODATE NEW PIPING
INSTALLATION. REINSTALL AFTER COMPLETION. SEE MECHANICAL FOR MORE
INFORMATION.
9 REMOVE EXISTING HORIZONTAL UNIT VENT AND PREP FOR NEW. REFER TO
MECHANICAL FOR MORE INFORMATION
10 REMOVE PORTION OF EXISTING ROOFING DOWN TO EXISTING DECK TO ACCOMMODATE
NEW RELIEF HOOD INSTALLATION. COORDINATE WITH MECHANICAL FOR SIZE AND
LOCATION. NOTE, AT STRUCTURAL METAL DECK, SEE DETAIL TO ADD STEEL PLATE AND
COORDINATE WITH MECHANICAL FOR INSTALLATION OF NEW RELIEF HOOD CURB.
11 REMOVE PORTION OF EXISTING GYPSUM BOARD FINISH TO ACCOMMODATE NEW
PIPING INSTALLATION WITHIN EXISTNG STUD WALL FOR NEW MECHANICAL UNIT. REFER
TO MECHANICAL AND ELECTRICAL FOR MORE INFORMATION.
12 SHIFT EXISTING TOILET PAPER DISPENSER TO ALLOW INSTALLATION OF NEW HYDRONIC
PIPING AND ENCLOSURE.
13 REMOVE EXISTING ENCLOSURE AT REFRIGERANT LINES. REFRIGERANT LINES TO REMAIN
AND BE ENCLOSED WITHIN NEW VERTICAL ENCLOSURE
14 REMOVE AND SALVAGE EXISTING WINDOW SHADE DEVICE TO ACCOMMODATE PIPE AND
VERTICAL ENCLOSURE INSTALLATION
EAST LEROY ELEMENTARY
UNIT
A
UNIT B UNIT C
KEY PLAN
SCALE: NO SCALE
3/32" = 1'-0"
OVERALL ROOF DEMOLITION PLAN
TS
T S
T
T S
EQ
EQ
EQ
EQ
EQ
EQ EQ EQ EQ
EQ EQ
EQ EQ
EQ
EQ
EQ EQ EQEQ
J
J
EQ
EQ
BOILER ROOM
MEN'S
TOILET
WOMEN'S
TOILET
MULTI-PURPOSE
ROOM
CLASSROOM
LOBBY
KITCHEN
TOILET
KITCHEN
STORAGE
STORAGE
CLASSROOM
TOILET
TOILET
A 101A
A 101A
SIM
A 101A
SIM
140A
140B
UNIT
B
UNIT
A
UNIT A
UNIT C
UPPER ROOF 2
108' - 8"
6"
16 GA BREAK METAL
ENCLOSURE W/ NO EXPOSED
FASTENERS. PAINT COLOR
TO MATCH WALL COLOR
PIPE AND INSULATION,
SEE MECHANICAL
CONCEALED FASTENER
CLIP W/ MASONRY
SCREWS
EXISTING CEILING TO
REMAIN, WHERE
APPLICABLE
'-0
A .F
.F
6"
18 GA REMOVABLE BREAK
METAL ENCLOSURE W/ NO
EXPOSED FASTENERS. PAINT
COLOR TO MATCH WALL
COLOR. EXTEND FROM FINISH
FLOOR TO HEIGHT OF 8'-2" AFF.
PIPE AND INSULATION,
SEE MECHANICAL AND
ELECTRICAL
CONCEALED FASTENER
CLIP W/ MASONRY SCREWS
LF
R E F E R T
O S
C H E D
U
LE
SCHED.
REFER TO
R E F E R T
O S
C H E D
U
LE
SCHED.
REFER TO
SCHED.
REFER TO 2"
R E F E R T
O S
C H E D
U
LE
F
IE
LD
V
E R
IF
Y
2"
TO SCHED.
REFER 2"
INSULATED
GLASS
LOWER LEVEL
96' - 0"
6"
18 GA REMOVABLE BREAK
METAL ENCLOSURE W/ NO
EXPOSED FASTENERS. PAINT
COLOR TO MATCH WALL
COLOR
PIPE AND INSULATION,
SEE MECHANICAL AND
ELECTRICAL
CONCEALED FASTENER
CLIP W/ MASONRY
SCREWS
5/8" GYPSUM BOARD,
BOTH SIDES
METAL STUDS AT
16" O.C.
METAL STUD
DOUBLE HEADER
HOLLOW METAL
FRAME - SEE SCHEDULE
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
F
IR
S T
F L O
O R
P L A
N
U N
IT
A
.1
A
A
E A
S T
L E
R O
Y E
L E
M E
N T
A R
Y M
E C
H A
N
IC
A L
U P
G R
A D
E S
E a s t L e ro y M ic h ig a n
A T
H E
N S
A R
E A
S C
H O
O L S
D E
C E
M B
E R
NOTES - ARCHITECTURAL
1 REFER TO CODE COMPLIANCE PLAN FOR WALL RATING LINES.
2 REFER TO FLOOR FINISH PLANS FOR INTERIOR ELEVATION CALLOUTS.
3 REFER TO SHEET A 500's FOR WALL AND CEILING ACCESS PANEL INFORMATION.
EAST LEROY ELEMENTARY
UNIT
A
UNIT B UNIT C
KEY PLAN
SCALE: NO SCALE
1/8" = 1'-0"
FIRST FLOOR PLAN - UNIT A
KEYED NOTES - ARCHITECTURAL - CONSTRUCTION
1 PATCH EXISITNG GYPSUM BOARD VENEER WHERE REMOVED TO ACCOMMODATE NEW
PIPING INSTALLATION. PAINT ENTIRE WALL. COLOR TO BE SELECTED BY OWNER /
ARCHITECT
2 NEW PAINTED METAL VERTICAL PIPE COVER ENCLOSURE, REFER TO DETAIL 2 ON SHEET
A 101A. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW
3 NEW PAINTED METAL PIPE COVER ENCLOSURE, ABOVE. REFER TO DETAIL 1 ON A
101B. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW
4 INFILL DOOR TRANSOM W/ (1) LAYER OF 5/8" TYPE 'X' GYPSUM BOARD ON BOTH SIDES
TO REPLACE RATED GLASS. PAINT TO MATCH EXISTING WALL COLOR.
5 NEW CEILING MOUNTED PAINTED METAL PIPE ENCLOSURE
6 PAINTED STEEL PLATE AT RELIEF OPENING, COLOR TO MATCH EXISTING METAL DECK.
SEE LONG SPAN DECK DETAIL 1 ON SHEET A 102 AND SEE MECHANICAL FOR MORE
INFORMATION
7 REINSTALL EXISTING PIPE ENCLOSURE COVER.
9 NEW ROOF PENETRATION, SEE MECHANICAL AND TYPICAL LONG-SPAN ROOF DECK
PENETRATION WITHOUT SUPPORT FRAMING DETAIL 1 ON SHEET A 102 FOR MORE
INFORMATION. PATCH AND REPAIR ROOFING TO MATCH EXISTING ISULATION AND
MEMBRANE. PROVIDE NEW ROOF CURB FOR RELIEF HOOD. PROVIDE CRICKETS AS
NECESSARY TO DIRECT WATER TO EXISTING DRAINS.
11 NEW MECHANICAL FLU PENETRATION, PATCH AND SEAL ROOF TO MATCH EXISTING.
REFER TO MECHANICAL.
12 PROVIDE NEW 1 HOUR STUD AND GYPSUM BOARD ENCLOSTURE AT TRANSOM ABOVE
DOOR
13 PATCH AND PAINT WALL WHERE WALL MOUNTED UNIT IS REPLACED.
14 NEW WALL MOUNTED HORIZONTAL PAINTED METAL PIPE COVER ENCLOSURE, SEE DETAIL
3 ON A 101A
1 1/2" = 1'-0"A 101A
1 TYP GYM WALL PIPE COVER
1 1/2" = 1'-0"A 101A
2 TYP VERTICAL PIPE COVER
FIRST FLOOR DOOR SCHEDULE
DOOR ROOM
ROOM NAME
FIRE RATING DOOR SIZE FRAME DETAILS
GLASS
ACCESS CONTROLS
HDWR. SET REMARKS
DOOR FRAME TYPE MAT FIN WIDTH HEIGHT ELEV MAT FIN HEAD JAMB SILL A-PHONE
BARRIER-F
REE
CARD
READER
ELEC. LOCK
HDWR. MAG HOLD
140A 140 BOILER ROOM - - F HM P-? 3' - 8" 6' - 8" 2 HM P-? - - - - No No No No No - -
140B 140 BOILER ROOM 45 MIN 45 MIN F HM P-? 3' - 4" 6' - 8" 1 HM P-? H1 - - - No No No No No - -
1/4" = 1'-0"
DOOR ELEVATION LEGEND
1/4" = 1'-0"
FRAME ELEVATION LEGEND
1 1/2" = 1'-0"A 101A
3 TYPICAL HORIZONTAL WALL PIPE COVER
1 1/2" = 1'-0"
H1
UP
TSTS
TSTSTS
TST
S
T
T S
T S
T T
T
T
EQ EQ
EQ
EQ
EQ EQ
EQ EQ
EQ
WAPWAP
WAP
S
WAP WAPWAP
A 101A
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CUSTODIAN
106 STAFF
CONFERENCE
GIRL'S TOILET
VAULT
OFFICE
CLASSROOM
152CLASSROOM
CLASSROOM
CONFERENCE
TOILET
152A
TOILET
153A
TOILET
154A CORRIDOR
CORRIDOR
7 2
UNIT B UNIT C
UNIT
B
UNIT
A
UNIT A
UNIT C
2 2 2
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
F
IR
S T
F L O
O R
P L A
N
U N
IT
B
.1
A
B
E A
S T
L E
R O
Y E
L E
M E
N T
A R
Y M
E C
H A
N
IC
A L
U P
G R
A D
E S
E a s t L e ro y M ic h ig a n
A T
H E
N S
A R
E A
S C
H O
O L S
D E
C E
M B
E R
NOTES - ARCHITECTURAL
1 REFER TO CODE COMPLIANCE PLAN FOR WALL RATING LINES.
2 REFER TO FLOOR FINISH PLANS FOR INTERIOR ELEVATION CALLOUTS.
3 REFER TO SHEET A 500's FOR WALL AND CEILING ACCESS PANEL INFORMATION.
KEYED NOTES - ARCHITECTURAL - CONSTRUCTION
1 PATCH EXISITNG GYPSUM BOARD VENEER WHERE REMOVED TO ACCOMMODATE NEW
PIPING INSTALLATION. PAINT ENTIRE WALL. COLOR TO BE SELECTED BY OWNER /
ARCHITECT
2 NEW PAINTED METAL VERTICAL PIPE COVER ENCLOSURE, REFER TO DETAIL 2 ON SHEET
A 101A. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW
3 NEW PAINTED METAL PIPE COVER ENCLOSURE, ABOVE. REFER TO DETAIL 1 ON A
101B. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW
4 INFILL DOOR TRANSOM W/ (1) LAYER OF 5/8" TYPE 'X' GYPSUM BOARD ON BOTH SIDES
TO REPLACE RATED GLASS. PAINT TO MATCH EXISTING WALL COLOR.
5 NEW CEILING MOUNTED PAINTED METAL PIPE ENCLOSURE
6 PAINTED STEEL PLATE AT RELIEF OPENING, COLOR TO MATCH EXISTING METAL DECK.
SEE LONG SPAN DECK DETAIL 1 ON SHEET A 102 AND SEE MECHANICAL FOR MORE
INFORMATION
7 REINSTALL EXISTING PIPE ENCLOSURE COVER.
9 NEW ROOF PENETRATION, SEE MECHANICAL AND TYPICAL LONG-SPAN ROOF DECK
PENETRATION WITHOUT SUPPORT FRAMING DETAIL 1 ON SHEET A 102 FOR MORE
INFORMATION. PATCH AND REPAIR ROOFING TO MATCH EXISTING ISULATION AND
MEMBRANE. PROVIDE NEW ROOF CURB FOR RELIEF HOOD. PROVIDE CRICKETS AS
NECESSARY TO DIRECT WATER TO EXISTING DRAINS.
11 NEW MECHANICAL FLU PENETRATION, PATCH AND SEAL ROOF TO MATCH EXISTING.
REFER TO MECHANICAL.
12 PROVIDE NEW 1 HOUR STUD AND GYPSUM BOARD ENCLOSTURE AT TRANSOM ABOVE
DOOR
13 PATCH AND PAINT WALL WHERE WALL MOUNTED UNIT IS REPLACED.
14 NEW WALL MOUNTED HORIZONTAL PAINTED METAL PIPE COVER ENCLOSURE, SEE DETAIL
3 ON A 101A
1/8" = 1'-0"
FIRST FLOOR PLAN - UNIT B
EAST LEROY ELEMENTARY
UNIT
A
UNIT B UNIT C
KEY PLAN
UP
TS TS TS
TSTSTS
T
T
T
T
T S
T
T
T S
T
T
EQ EQ EQ EQ
EQEQEQ
EQ
CORRIDOR
VESTIBULE
CUSTODIAN
TOILET
STAFF
CONFERENCE
LIBRARY
DATA
RELATED
ACTIVITIES
COUNSELOR
113 COMPUTER
LAB
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
BOY'S TOILET
HEALTH
TOILET
OFFICE
GIRL'S TOILET
VAULT
OFFICE
OFFICE
WORK ROOM
A 101A
SIM
A 101A
UNIT B UNIT C
UNIT A
UNIT C
2 2
2 2 2
V
IF
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
F
IR
S T
F L O
O R
P L A
N
U N
IT
C
.1
A
C
E A
S T
L E
R O
Y E
L E
M E
N T
A R
Y M
E C
H A
N
IC
A L
U P
G R
A D
E S
E a s t L e ro y M ic h ig a n
A T
H E
N S
A R
E A
S C
H O
O L S
D E
C E
M B
E R
NOTES - ARCHITECTURAL
1 REFER TO CODE COMPLIANCE PLAN FOR WALL RATING LINES.
2 REFER TO FLOOR FINISH PLANS FOR INTERIOR ELEVATION CALLOUTS.
3 REFER TO SHEET A 500's FOR WALL AND CEILING ACCESS PANEL INFORMATION.
KEYED NOTES - ARCHITECTURAL - CONSTRUCTION
1 PATCH EXISITNG GYPSUM BOARD VENEER WHERE REMOVED TO ACCOMMODATE NEW
PIPING INSTALLATION. PAINT ENTIRE WALL. COLOR TO BE SELECTED BY OWNER /
ARCHITECT
2 NEW PAINTED METAL VERTICAL PIPE COVER ENCLOSURE, REFER TO DETAIL 2 ON SHEET
A 101A. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW
3 NEW PAINTED METAL PIPE COVER ENCLOSURE, ABOVE. REFER TO DETAIL 1 ON A
101B. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW
4 INFILL DOOR TRANSOM W/ (1) LAYER OF 5/8" TYPE 'X' GYPSUM BOARD ON BOTH SIDES
TO REPLACE RATED GLASS. PAINT TO MATCH EXISTING WALL COLOR.
5 NEW CEILING MOUNTED PAINTED METAL PIPE ENCLOSURE
6 PAINTED STEEL PLATE AT RELIEF OPENING, COLOR TO MATCH EXISTING METAL DECK.
SEE LONG SPAN DECK DETAIL 1 ON SHEET A 102 AND SEE MECHANICAL FOR MORE
INFORMATION
7 REINSTALL EXISTING PIPE ENCLOSURE COVER.
9 NEW ROOF PENETRATION, SEE MECHANICAL AND TYPICAL LONG-SPAN ROOF DECK
PENETRATION WITHOUT SUPPORT FRAMING DETAIL 1 ON SHEET A 102 FOR MORE
INFORMATION. PATCH AND REPAIR ROOFING TO MATCH EXISTING ISULATION AND
MEMBRANE. PROVIDE NEW ROOF CURB FOR RELIEF HOOD. PROVIDE CRICKETS AS
NECESSARY TO DIRECT WATER TO EXISTING DRAINS.
11 NEW MECHANICAL FLU PENETRATION, PATCH AND SEAL ROOF TO MATCH EXISTING.
REFER TO MECHANICAL.
12 PROVIDE NEW 1 HOUR STUD AND GYPSUM BOARD ENCLOSTURE AT TRANSOM ABOVE
DOOR
13 PATCH AND PAINT WALL WHERE WALL MOUNTED UNIT IS REPLACED.
14 NEW WALL MOUNTED HORIZONTAL PAINTED METAL PIPE COVER ENCLOSURE, SEE DETAIL
3 ON A 101A
EAST LEROY ELEMENTARY
UNIT
A
UNIT B UNIT C
KEY PLAN
SCALE: NO SCALE
1/8" = 1'-0"
A 101C - FIRST FLOOR PLAN - UNIT C
UNIT A
UNIT C
UNIT B UNIT C
UNIT
B
UNIT
A
ROOF DECK
INSULATION
FLASHING
VENT PIPE
SEALANT
ROOFING
CANT STRIP
11/2" RIGID INSULATION
EXISTING ROOF CURB
COUNTER FLASHING WITH
APPROVED SEALING WASHER
AND FASTENER @ 6" O.C.
EXISTING ROOF MOUNTED EQUIPMENT
TREATED 2x4 NAILER, AS REQUIRED
M
IN
LAP SEALANT
MEMBRANE ROOF
EXISTING TREATED NAILER(s)
EXISTING ROOF DECK
EXISTING RIGID
INSULATION TO REAMAIN
ROOF STRUCTURE (SEE
STRUCTURAL)
TREATED NAILER(s) AS REQUIRED
ROOF DECK
CANT STRIP
11/2" RIGID INSULATION
EXISTING ROOF CURB
COUNTER FLASHING WITH
APPROVED SEALING WASHER
AND FASTENER @ 6" O.C.
EXISTING ROOF MOUNTED EQUIPMENT
TREATED 2x4 NAILER, AS REQUIRED
M
IN
LAP SEALANT
MEMBRANE ROOF
EXISTING RIGID
INSULATION TO REAMAIN
NOTE:
FOR TYPICAL INSTANCES BELOW AHU's &
RTU's WHERE ROOF DECK RUNS
CONTINUOUS, PROVIDE NOISE ISOLATION
REQUIREMENTS USING (2) LAYERS OF
5/8" GYPSUM BOARD (TOP & BOTTOM (4
TOTAL)) WITH (2) LAYERS OF 1-1/2"
MINERAL FIBER INSULATION BETWEEN.
PENETRATIONS UP TO 12" WIDE;
REMOVE ENTIRE WIDTH OF ONE SINGLE
DECK PAN FOR A MAX 24" LENGTH.
ADJUST LOCATIONS AS REQUIRED TO
LIMIT TO ONE PAN.
12" MAX
W
2' - 6"
16 GA. SHEET (G60 GALVANIZED)
TYPICAL TOP AND BOTTOM OF
DECK. FASTENING SHOWN IS
TYPICAL TOP AND BOTTOM.
#12 TEK SCREWS
QUANTITY = (W) ROWS OF (3),
WHERE W = (WIDTH OF DECK
OPENING IN INCHES, NOT TO
EXCEED 12")
TY
P
/2
#12 TEK SCREWS @6"
PENETRATIONS NOT PERMITTED IN
(2) ADJACENT DECK PANS
#12 TEK SCREWS
QUANTITY = (W) ROWS OF (3),
WHERE W = (WIDTH OF DECK
OPENING IN INCHES, NOT TO
EXCEED 12")
PLAN VIEW
A A
SECTION A-A
16 GA. SHEET (G60 GALVANIZED).
SEE PLAN VIEW FOR FASTENING
NOTES:
1. 16 GA. SHEET SHOWN IS REQUIRED
ON TOP AND BOTTOM OF DECK.
SCREW FASTENING SHOWN IS TYPICAL
TOP AND BOTTOM.
2. FIELD LOCATE PENETRATIONS TO
ENSURE ONLY ONE DECK PAN IS
REMOVED BY A PENETRATION.
3. DECK MUST BE CLEANLY CUT BY
MECHANICAL METHODS (TORCH
CUTTING NOT PERMITTED).
4. OVERCUTTING BEYOND CORNERS OF
OPENING IS NOT PERMITTED.
3" 3"
M
A X.
/2
MAX.
1' - 0"
NOTE: PAINT EXPOSED STEEL
PLATE AND SCREWS, COLOR
TO MATCH EXISTING ROOF
DECK.
SEE MECHANICAL FOR GRILL
COVER AT OPENING. ATTACH
TO STEEL PLATE WITH
PERIMETER J MOLDING
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
O V
E R
A L L R
O O
F P
L A
N
.1
A
E A
S T
L E
R O
Y E
L E
M E
N T
A R
Y M
E C
H A
N
IC
A L
U P
G R
A D
E S
E a s t L e ro y M ic h ig a n
A T
H E
N S
A R
E A
S C
H O
O L S
D E
C E
M B
E R
3/32" = 1'-0"
OVERALL ROOF PLAN
EAST LEROY ELEMENTARY
UNIT
A
UNIT B UNIT C
KEY PLAN
SCALE: NO SCALE
KEYED NOTES - ARCHITECTURAL - CONSTRUCTION
1 PATCH EXISITNG GYPSUM BOARD VENEER WHERE REMOVED TO ACCOMMODATE NEW
PIPING INSTALLATION. PAINT ENTIRE WALL. COLOR TO BE SELECTED BY OWNER /
ARCHITECT
2 NEW PAINTED METAL VERTICAL PIPE COVER ENCLOSURE, REFER TO DETAIL 2 ON SHEET
A 101A. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW
3 NEW PAINTED METAL PIPE COVER ENCLOSURE, ABOVE. REFER TO DETAIL 1 ON A
101B. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW
4 INFILL DOOR TRANSOM W/ (1) LAYER OF 5/8" TYPE 'X' GYPSUM BOARD ON BOTH SIDES
TO REPLACE RATED GLASS. PAINT TO MATCH EXISTING WALL COLOR.
5 NEW CEILING MOUNTED PAINTED METAL PIPE ENCLOSURE
6 PAINTED STEEL PLATE AT RELIEF OPENING, COLOR TO MATCH EXISTING METAL DECK.
SEE LONG SPAN DECK DETAIL 1 ON SHEET A 102 AND SEE MECHANICAL FOR MORE
INFORMATION
7 REINSTALL EXISTING PIPE ENCLOSURE COVER.
9 NEW ROOF PENETRATION, SEE MECHANICAL AND TYPICAL LONG-SPAN ROOF DECK
PENETRATION WITHOUT SUPPORT FRAMING DETAIL 1 ON SHEET A 102 FOR MORE
INFORMATION. PATCH AND REPAIR ROOFING TO MATCH EXISTING ISULATION AND
MEMBRANE. PROVIDE NEW ROOF CURB FOR RELIEF HOOD. PROVIDE CRICKETS AS
NECESSARY TO DIRECT WATER TO EXISTING DRAINS.
11 NEW MECHANICAL FLU PENETRATION, PATCH AND SEAL ROOF TO MATCH EXISTING.
REFER TO MECHANICAL.
12 PROVIDE NEW 1 HOUR STUD AND GYPSUM BOARD ENCLOSTURE AT TRANSOM ABOVE
DOOR
13 PATCH AND PAINT WALL WHERE WALL MOUNTED UNIT IS REPLACED.
14 NEW WALL MOUNTED HORIZONTAL PAINTED METAL PIPE COVER ENCLOSURE, SEE DETAIL
3 ON A 101A
1 1/2" = 1'-0"
TYPICAL ROOF PENETRATION
1 1/2" = 1'-0"
TYPICAL EXISTING ROOF CURB
1 1/2" = 1'-0"
TYPICAL NEW ROOF CURB
3/4" = 1'-0"A 102
1 LONG-SPAN ROOF DECK PENETRATION WITHOUT SUPPORT FRAMING
LOBBY
MEN'S
TOILET
WOMEN'S
TOILET
BOILER ROOM
KITCHEN
TOILET
KITCHEN
STORAGE
STORAGE
MULTI-PURPOSE
ROOM
CLASSROOM
TOILET
TOILET
CLASSROOM
VESTIBULE
A 101A
A 101A
SIM
A 101A
SIM
UNIT
B
UNIT
A
UNIT A
UNIT C
GYPSUM BOARD
LAY-IN ACOUSTICAL TILE GRID
OR LIGHTING - REFER TO ELECTRICAL LIGHTING PLAN
MECHANICAL - REFER TO MECHANICAL SHEET METAL PLAN
KEY - REFLECTED CEILING
PAINTED BENT METAL ENCLOSURE
EXPOSED CEILING
GENERAL NOTES - REFLECTED CEILINGS
1. WHERE CEILING TILE IS LESS THAN 3" AT PERIMETER OF ROOM PROVIDE A CUT 2x4
TILE IN LIEU OF FULL 2x2 TILE AND SMALL PIECE OF TILE OR DOUBLE GRID - MATCH
2x2 FOR STYLE AND COLOR.
2. AT AREAS OF EXPOSED CEILING PAINT ALL STRUCTURE, DUCTWORK, PIPING, CONDUIT,
HANGERS ETC., COORDINATE WITH MECHANICAL, ELECTRICAL AND PLUMBING
SPECIFICATIONS. REFER TO THE REFLECTED CEILING PLANS FOR PAINT COLORS.
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
F
IR
S T
F L O
O R
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
U N
IT
A
.1
A
A
E A
S T
L E
R O
Y E
L E
M E
N T
A R
Y M
E C
H A
N
IC
A L
U P
G R
A D
E S
E a s t L e ro y M ic h ig a n
A T
H E
N S
A R
E A
S C
H O
O L S
D E
C E
M B
E R
1/8" = 1'-0"
REFLECTED CEILING PLAN - UNIT A
EAST LEROY ELEMENTARY
UNIT
A
UNIT B UNIT C
KEY PLAN
SCALE: NO SCALE
KEYED NOTES - ARCHITECTURAL - CONSTRUCTION
1 PATCH EXISITNG GYPSUM BOARD VENEER WHERE REMOVED TO ACCOMMODATE NEW
PIPING INSTALLATION. PAINT ENTIRE WALL. COLOR TO BE SELECTED BY OWNER /
ARCHITECT
2 NEW PAINTED METAL VERTICAL PIPE COVER ENCLOSURE, REFER TO DETAIL 2 ON SHEET
A 101A. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW
3 NEW PAINTED METAL PIPE COVER ENCLOSURE, ABOVE. REFER TO DETAIL 1 ON A
101B. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW
4 INFILL DOOR TRANSOM W/ (1) LAYER OF 5/8" TYPE 'X' GYPSUM BOARD ON BOTH SIDES
TO REPLACE RATED GLASS. PAINT TO MATCH EXISTING WALL COLOR.
5 NEW CEILING MOUNTED PAINTED METAL PIPE ENCLOSURE
6 PAINTED STEEL PLATE AT RELIEF OPENING, COLOR TO MATCH EXISTING METAL DECK.
SEE LONG SPAN DECK DETAIL 1 ON SHEET A 102 AND SEE MECHANICAL FOR MORE
INFORMATION
7 REINSTALL EXISTING PIPE ENCLOSURE COVER.
9 NEW ROOF PENETRATION, SEE MECHANICAL AND TYPICAL LONG-SPAN ROOF DECK
PENETRATION WITHOUT SUPPORT FRAMING DETAIL 1 ON SHEET A 102 FOR MORE
INFORMATION. PATCH AND REPAIR ROOFING TO MATCH EXISTING ISULATION AND
MEMBRANE. PROVIDE NEW ROOF CURB FOR RELIEF HOOD. PROVIDE CRICKETS AS
NECESSARY TO DIRECT WATER TO EXISTING DRAINS.
11 NEW MECHANICAL FLU PENETRATION, PATCH AND SEAL ROOF TO MATCH EXISTING.
REFER TO MECHANICAL.
12 PROVIDE NEW 1 HOUR STUD AND GYPSUM BOARD ENCLOSTURE AT TRANSOM ABOVE
DOOR
13 PATCH AND PAINT WALL WHERE WALL MOUNTED UNIT IS REPLACED.
14 NEW WALL MOUNTED HORIZONTAL PAINTED METAL PIPE COVER ENCLOSURE, SEE DETAIL
3 ON A 101A
T T
CORRIDOR
CLASSROOM
CLASSROOM
CLASSROOM
CUSTODIAN
TOILET
STAFF
CONFERENCE
GIRL'S TOILET
VAULT
OFFICE
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
152CLASSROOM
CLASSROOM
CONFERENCE
TOILET
152A
TOILET
153A
TOILET
154A CORRIDOR
58"
6 6 6
6 6 6
UNIT B UNIT C
UNIT
B
UNIT
A
UNIT A
UNIT C
2 2
2 2
CORRIDOR
GYPSUM BOARD
LAY-IN ACOUSTICAL TILE GRID
OR LIGHTING - REFER TO ELECTRICAL LIGHTING PLAN
MECHANICAL - REFER TO MECHANICAL SHEET METAL PLAN
KEY - REFLECTED CEILING
PAINTED BENT METAL ENCLOSURE
EXPOSED CEILING
GENERAL NOTES - REFLECTED CEILINGS
1. WHERE CEILING TILE IS LESS THAN 3" AT PERIMETER OF ROOM PROVIDE A CUT 2x4
TILE IN LIEU OF FULL 2x2 TILE AND SMALL PIECE OF TILE OR DOUBLE GRID - MATCH
2x2 FOR STYLE AND COLOR.
2. AT AREAS OF EXPOSED CEILING PAINT ALL STRUCTURE, DUCTWORK, PIPING, CONDUIT,
HANGERS ETC., COORDINATE WITH MECHANICAL, ELECTRICAL AND PLUMBING
SPECIFICATIONS. REFER TO THE REFLECTED CEILING PLANS FOR PAINT COLORS.
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
F
IR
S T
F L O
O R
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
U N
IT
B
.1
A
B
E A
S T
L E
R O
Y E
L E
M E
N T
A R
Y M
E C
H A
N
IC
A L
U P
G R
A D
E S
E a s t L e ro y M ic h ig a n
A T
H E
N S
A R
E A
S C
H O
O L S
D E
C E
M B
E R
1/8" = 1'-0"
REFLECTED CEILING PLAN - UNIT B
EAST LEROY ELEMENTARY
UNIT
A
UNIT B UNIT C
KEY PLAN
SCALE: NO SCALE
KEYED NOTES - ARCHITECTURAL - CONSTRUCTION
1 PATCH EXISITNG GYPSUM BOARD VENEER WHERE REMOVED TO ACCOMMODATE NEW
PIPING INSTALLATION. PAINT ENTIRE WALL. COLOR TO BE SELECTED BY OWNER /
ARCHITECT
2 NEW PAINTED METAL VERTICAL PIPE COVER ENCLOSURE, REFER TO DETAIL 2 ON SHEET
A 101A. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW
3 NEW PAINTED METAL PIPE COVER ENCLOSURE, ABOVE. REFER TO DETAIL 1 ON A
101B. SUBMIT COLORS FOR OWNER / ARCHITECT REVIEW
4 INFILL DOOR TRANSOM W/ (1) LAYER OF 5/8" TYPE 'X' GYPSUM BOARD ON BOTH SIDES
TO REPLACE RATED GLASS. PAINT TO MATCH EXISTING WALL COLOR.
5 NEW CEILING MOUNTED PAINTED METAL PIPE ENCLOSURE
6 PAINTED STEEL PLATE AT RELIEF OPENING, COLOR TO MATCH EXISTING METAL DECK.
SEE LONG SPAN DECK DETAIL 1 ON SHEET A 102 AND SEE MECHANICAL FOR MORE
INFORMATION
7 REINSTALL EXISTING PIPE ENCLOSURE COVER.
9 NEW ROOF PENETRATION, SEE MECHANICAL AND TYPICAL LONG-SPAN ROOF DECK
PENETRATION WITHOUT SUPPORT FRAMING DETAIL 1 ON SHEET A 102 FOR MORE
INFORMATION. PATCH AND REPAIR ROOFING TO MATCH EXISTING ISULATION AND
MEMBRANE. PROVIDE NEW ROOF CURB FOR RELIEF HOOD. PROVIDE CRICKETS AS
NECESSARY TO DIRECT WATER TO EXISTING DRAINS.
11 NEW MECHANICAL FLU PENETRATION, PATCH AND SEAL ROOF TO MATCH EXISTING.
REFER TO MECHANICAL.
12 PROVIDE NEW 1 HOUR STUD AND GYPSUM BOARD ENCLOSTURE AT TRANSOM ABOVE
DOOR
13 PATCH AND PAINT WALL WHERE WALL MOUNTED UNIT IS REPLACED.
14 NEW WALL MOUNTED HORIZONTAL PAINTED METAL PIPE COVER ENCLOSURE, SEE DETAIL
CORRIDOR
CUSTODIAN
TOILET
STAFF
CONFERENCE
GIRL'S TOILET
VAULT
OFFICE
132 VESTIBULE
LIBRARY
DATA
RELATED
ACTIVITIES
COUNSELOR
COMPUTER
LAB
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
BOY'S TOILET
HEALTH
TOILET
OFFICE
OFFICE
WORK ROOM
2 2
UNIT B UNIT C
UNIT
B
UNIT
A
UNIT A
UNIT C
2 2
GYPSUM BOARD
LAY-IN ACOUSTICAL TILE GRID
OR LIGHTING - REFER TO ELECTRICAL LIGHTING PLAN
MECHANICAL - REFER TO MECHANICAL SHEET METAL PLAN
KEY - REFLECTED CEILING
PAINTED BENT METAL ENCLOSURE
EXPOSED CEILING
GENERAL NOTES - REFLECTED CEILINGS
1. WHERE CEILING TILE IS LESS THAN 3" AT PERIMETER OF ROOM PROVIDE A CUT 2x4
TILE IN LIEU OF FULL 2x2 TILE AND SMALL PIECE OF TILE OR DOUBLE GRID - MATCH
2x2 FOR STYLE AND COLOR.
2. AT AREAS OF EXPOSED CEILING PAINT ALL STRUCTURE, DUCTWORK, PIPING, CONDUIT,
HANGERS ETC., COORDINATE WITH MECHANICAL, ELECTRICAL AND PLUMBING
SPECIFICATIONS. REFER TO THE REFLECTED CEILING PLANS FOR PAINT COLORS.
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
F
IR
S T
F L O
O R
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
U N
IT
C
.1
A
C
E A
S T
L E
R O
Y E
L E
M E
N T
A R
Y M
E C
H A
N
IC
A L
U P
G R
A…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .