Exhibit 2 Unit Table and Silvicultural Certification Standards.xlsx

XLSX spreadsheet 14 KB Posted

Attached to
USDA Forest Service LMIR BPA Call for Lolo NF Stocking Surveys AMD 0001
Solicitation number
1284LM26Q0035
Issued by

About this file

This is a silvicultural certification standards and unit table for stocking surveys across the Lolo National Forest in Missoula and Powell Counties, Montana. The spreadsheet details 47 mandatory units and 2 optional units distributed across three blocks (Missoula, Seeley districts), encompassing 2,138 total acres with 1,331 survey plots. Units are identified by polygon ID and unit name, with acreage ranging from 3 to 414 acres. The file specifies planting histories, Tree Per Acre (TPA) targets, species composition requirements (including ponderosa pine, western larch, Douglas fir, lodgepole pine, and aspen), stocking percentages (primarily 70% stocked at 150 TPA), minimum height requirements (ranging from 1 to 2 feet), and performance windows (June 15–November 1 or July 15–November 1 depending on location). Mandatory units total 1,636 acres across 1,036 plots, while optional units total 502 acres across 295 plots. Multiple units include replanting requirements with specific species mixes and plot counts noted for years 2019–2024. Access notes are provided for challenging terrain where direct road access is unavailable, requiring walk-in or alternative approach routes. This unit table establishes the silvicultural standards and plot-based monitoring framework for a BPA Call Order issued under the USDA Forest Service's Land Management Integrated Resources (LMIR) program for stocking survey work on Lolo National Forest.

View the file

Other files

File Type Posted
LMIR BPA Call Order AMD 0001.doc DOC document
SF-30.pdf PDF
Exhibit 6 Stocking Survey CoverSheet.pdf PDF
LMIR BPA Call Order.doc DOC document
Exhibit 7 Stocking Survey Scoring.pdf PDF
Wage Determination Missoula County.pdf PDF
Exhibit 3 Map Package.pdf PDF
Exhibit 5 Plot Survey Form.xlsx XLSX spreadsheet
Exhibit 1 Statement of Work.docx DOCX document
Wage Determination Granite Powell.pdf PDF
Exhibit 4 Regeneration Quick Plot Form.pdf PDF
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

BlockDistrictPolygonUnit NameBid StatusAcres# PlotsPlant vs. NRGPlanted TPACert StandardsAccess NotesUnit-Specific Performance Period
1Missoula011603A080701001000S FORK LOLO 6Mandatory38192019 Plant213 PP, 8 WL150 TPA/70% stocked, 80%WL/PP, 2' HT6/15-11/1
1Missoula011603RA20170003000LOLO PEAK 3Mandatory226226NRG150 TPA/70% stocked, 1' HTWashout on Mormon Crk, access only from NW corner6/15-11/1
1Missoula011603RA20170050002LOLO PEAK 5Mandatory300150NRG150 TPA/70% stocked, 1' HT6/15-11/1
1Missoula011603RA20170108000LOLO PEAK 108Mandatory4343NRG150 TPA/70% stocked, 1' HTWashout on Mormon Crk, walk in from NW corner of Lolo Pk 36/15-11/1
Block 1 - Total -Mandatory607438
1Missoula011603RA20170058000LOLO PEAK 58Optional8888NRG150 TPA/70% stocked, 1' HT6/15-11/1
Block 1 - Optional8888
2Seeley011606A070101003000LIBERTY NEPA UNIT 3Mandatory6666NRG150tpa/70% stocked, 60% WL/LP/ES/PP, 2' HT7/15-11/1
2Seeley011606A070101006002LIBERTY 2 UNIT 12Mandatory33172023 Plant, 2025 Replant251 WL; Replant 261 WL200 TPA/70% stocked, 75% WL/PP, 1' HT7/15-11/1
2Seeley011606A070101007002LIBERTY 2 UNIT 13AMandatory28142023 Plant, 2024 ReplantReplant 251 WL200 TPA/70% stocked, 75% WL/PP, 1' HT7/15-11/1
2Seeley011606RA2017LI08000LIBERTY 8Mandatory2915NRG150 TPA/70% stocked, 1' HT7/15-11/1
2Seeley011606RA2017LI14000LIBERTY 14Mandatory12462NRG150 TPA/70% stocked, 1' HT7/15-11/1
2Seeley011606RA2017LI16000LIBERTY 16Mandatory3216NRG150 TPA/70% stocked, 1' HT7/15-11/1
2Seeley011606RA2017LI29001LIBERTY 29Mandatory12261NRG150 TPA/70% stocked, 1' HT7/15-11/1
Block 2 - Total -Mandatory434251
2Missoula011603RA2017LI07001LIBERTY 7Optional414207NRG150 TPA/70% stocked, 1' HTAccess from South unlikely; probably walk-in from Gold Peak6/15-11/1
Block 2 - Optional414207
3Seeley011606A120301003000RICE CRISPY NEPA UNIT 176Mandatory95NRG150 TPA/70% stocked, 80% WL/LP/PP, 2' HT7/15-11/1
3Seeley011606A120301004000RICE CRISPY NEPA UNIT 165Mandatory44NRG150 TPA/70% stocked, 80%WL/LP, 2' HT7/15-11/1
3Seeley011606A120301008000RICE RIDGE NEPA UNIT 707Mandatory6533NRG150 TPA/70% stocked, >75%WL, 2' HT7/15-11/1
3Seeley011606A230301004000RICE CRISPY NEPA UNIT 75Mandatory168NRG150 TPA/70% stocked, 80%WL/LP, 2' HT7/15-11/1
3Seeley011606A230301006000RICE CRISPY NEPA UNIT 175Mandatory189NRG150 TPA/70% stocked, 80% WL/LP/PP, 2' HT7/15-11/1
3Seeley011606A250200105000RICE CRISPY NEPA UNIT 185Mandatory22222019 Plant, 2023 Replant209 PP, Replant 60 PP150 TPA/70% stocked, 80% WL/LP/PP, 2' HT7/15-11/1
3Seeley011606A250201008000RICE RIDGE 1AMandatory1892023 Plant197 WL, 27 PP150 TPA/70% stocked, >50% WL/LP/aspen, 2' HT7/15-11/1
3Seeley011606A250401004000RICE RIDGE 1BMandatory1582024 Plant197 WL, 27 PP150 TPA/70% stocked, >50% WL/LP/aspen, 2' HT7/15-11/1
3Seeley011606A270201021000RICE RIDGE 2Mandatory1682024 Plant188 PP150 TPA/70% stocked, >50% PP/WL/LP, 2' HT7/15-11/1
3Seeley011606A270401000000LEFT MULE NEPA UNIT 61Mandatory1892022 Plant, 2023 Replant96 PP; Replant 311 PP150 TPA/70% stocked, 70% PP/WL, 1'HT7/15-11/1
3Seeley011606A280101012000LEFT MULE UNIT 61Mandatory1372022 Plant96 PP150 TPA/70% stocked, 70% PP/WL, 1'HT7/15-11/1
3Seeley011606A290100009005LEFT MULE NEPA UNIT 35Mandatory22222022 Plant, 2024 Replant195 WL and 36 PP; 256 PP150 TPA/70% stocked, 70% PP/WL, 1'HT7/15-11/1
3Seeley011606A290100010001LEFT MULE UNIT 42EMandatory2828Plant 2022, Replant 202483PP;Replant 268 PP150 TPA/70% stocked, 70% PP/WL, 1'HT7/15-11/1
3Seeley011606A290101002000LEFT MULE UNIT 42Mandatory95Plant 2022, Replant 2024293 PP; Replant 233 WL150 TPA/70% stocked, 70% PP/WL, 1'HT7/15-11/1
3Seeley011606A290101007000LEFT MULE UNIT 46Mandatory2513Plant 2022, Replant 2024176WL and 128 PP; Replant 141 PP150 TPA/70% stocked, 70% PP/WL, 1'HT7/15-11/1
3Seeley011606A290101010000LEFT MULE UNIT 46AMandatory126Plant 2022, Replant 2024100 PP and 200WL; Replant 100 WL and 150 PP150 TPA/70% stocked, 70% PP/WL, 1'HT7/15-11/1
3Seeley011606A290201007000LEFT MULE NEPA UNIT 32Mandatory3618Plant 2022, Replant 2024100 WL and 170 PP;Replant 150 WL150 TPA/70% stocked, 70% PP/WL, 1'HT7/15-11/1
3Seeley011606A290201008000LEFT MULE NEPA UNIT 31Mandatory116Plant 2022, Replant 2024218 PP and 73 WL; Replant 245 PP150 TPA/70% stocked, 70% PP/WL, 1'HT7/15-11/1
3Seeley011606A290201010002LEFT MULE NEPA UNIT 215Mandatory342022 Plant140 PP150 TPA/70% stocked, 70% PP/WL, 1'HT7/15-11/1
3Seeley011606A290201014000LEFT MULE NEPA UNIT 33Mandatory33172024 Plant176 PP150 TPA/70% stocked, 70% PP/WL, 1'HT7/15-11/1
3Seeley011606A290201017000LEFT MULE UNIT 31AMandatory137Plant 2022, Replant 2024293 PP; Replant 150 PP150 TPA/70% stocked, 70% PP/WL, 1'HT7/15-11/1
3Seeley011606A290201018000LEFT MULE UNIT 31BMandatory189Plant 2022, Replant 2024199 PP and 144 WL; Replant 150 PP150 TPA/70% stocked, 70% PP/WL, 1'HT7/15-11/1
3Seeley011606A290201020001LEFT MULE UNIT 31CMandatory116Plant 2022, Replant 2024349 PP150 TPA/70% stocked, 70% PP/WL, 1'HT7/15-11/1
3Seeley011606A310201001001DARK HORSE NEPA UNIT 24Mandatory3618Plant 202278 PP AND 163 WL150 TPA/70% stocked, PP/WL, 2' HT7/15-11/1
3Seeley011606A310401007002DARK HORSE NEPA UNIT 23Mandatory168Plant280 PP150 TPA/70% stocked, PP/WL, 2' HT7/15-11/1
3Seeley011606A310401008000DARK HORSE NEPA UNIT 27EMandatory5025Plant 2022, Replant 2024176 PP;Replant 24 PP150 TPA/70% stocked, PP/WL/DF/LP, 2' HT7/15-11/1
3Seeley011606A310401016001DARK HORSE NEPA UNIT 22Mandatory952022 Plant249 PP100 TPA/70% stocked, PP/WL, 2' HT7/15-11/1
3Seeley011606A320201000000RICE RIDGE NEPA UNIT 19Mandatory85NRG150 TPA/70% stocked, >50% PP/WL/LP, 2' HT7/15-11/1
3Seeley011606A320201001000DARK HORSE NEPA UNIT 19Mandatory105NRG150 TPA/70% stocked, PP/WL/DF/LP, 2' HT7/15-11/1
3Seeley011606A320201002000DARK HORSE NEPA UNIT 17Mandatory2513NRG150 TPA/70% stocked, PP/WL/DF/LP, 2' HT7/15-11/1
3Seeley011606A320301000000DARK HORSE UNIT 19BMandatory65NRG150 TPA/70% stocked, PP/WL/DF/LP, 2' HT7/15-11/1
Block 3 - Total - Mandatory595347
Total - Mandatory16361036
Total - Optional502295

File details come from the government source that posted it. Updated .