Exhibit 2 - Floorplan for Memphis Cotton Classing Facility.pdf
PDF 256 KB Posted
- Solicitation number
- 12639525Q0124
About this file
This document is a floor plan for the USDA Cotton and Tobacco Program facility located in Memphis, Tennessee, showing a detailed architectural drawing of the existing building conditions. The floor plan depicts multiple specialized rooms and areas including laboratories (Quality Assurance, Classing, Standards Testing), administrative spaces (Division Director and Assistant Director offices), support areas (break rooms, vestibules, storage rooms), and functional zones like shipping/receiving, tool rooms, and air locks. The drawing is dated 01/29/2014 and labeled as an original "Attachment B" drawing from Fanning, Fanning & Associates, documenting the mechanical, plumbing, and electrical systems of the building in their current state. The plan is structured across multiple grid sections (labeled 1-6) and includes specific room numbers and designations for each space within the facility.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INFORMATION
TECHNOLOGY
DIVISION
144B
DATA
CENTER
INFORMATION
TECHNOLOGY
DIVISION
DIVISION
DIRECTOR
DEPUTY
ADMINISTRATOR
CONFERENCE
ROOM
STORAGE
QUALITY
ASSURANCE
DIVISION
QUALITY
ASSURANCE
LABORATORY
MEN
WOMEN
STORAGE
AIR
LOCK
SUPERVISOR
155A
ELECTRICAL
STAIR
QUALITY
ASSURANCE
COORDINATOR
TOOL ROOM
CORRIDOR
VESTIBULE
VESTIBULE
CORRIDOR
BREAK ROOM
UP
AIR LOCK
STORAGE
AIR
COMPRESSORS
BALE PRESS
AIR LOCK
STORAGE
QUALITY ASSURANCE
RECEIVING
ROOM
CLASSING
LABORATORY 1
DIVISION
DIRECTOR
AIR LOCK
CORRIDOR
BUDGET
TECHNICIAN
COMMUNICATIONS
ROOM 2
CORRIDOR
CORRIDOR
CORRIDOR
LOBBY
LOADING
DOCK
MARKET
NEWS
DIVISION
DIVISON
DIRECTOR
COMMUNICATIONS
ROOM 1
SECURITY
143A
ASSISTANT
DIVISION
DIRECTOR
144A
ASSISTANT
DIVISION
DIRECTOR
147A
ASSISTANT
DIVISION
DIRECTOR
162A
INFORMATION
TECHNOLOGY
WORKROOM
144C
DEPUTY
RECEPTION
148A
MARKET
NEWS
REPORTER
147B
CONFERENCE
146A
STORAGE/
FILING
146B
HSPD12
A1
LEVELING FLOOR PLAN
1/8"=1'-0" INCORPORATED MODIFICATIONS (ATTACHMENT 1-6)
MATCHLINE
MATCHLINE
GENERAL NOTES
A. DRAWING INCLUDES ALL FLOOR PLAN MODIFICATIONS TO DATE;
CONTRACTOR SHALL CONDUCT BUILDING SURVEY TO VERIFY ALL SHOWN
MODIFICATIONS & MAKE NOTE OF ANY MODIFICATIONS NOT SHOWN ON
INCLUDED PLANS
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
NORTH
ISSUING OFFICE:
NO DESCRIPTIONDATE
PROJECT NO:
KEY PLAN
654321
654321
A
B
C
D
E
LUBBOCK 9382.13
1 01/29/2014 100% ISSUE
A-101
ATTACHMENT 1: REFERENCE ONLY!
ORIGINAL "ATTACHMENT B" DRAWING FROM FANNING,
FANNING & ASSOCIATES DESCRIBING THE
MECHANICAL PLUMBING AND ELECTRICAL SYSTEMS IN
THE BUILDING AS THEY EXIST CURRENTLY.
BREAK ROOM
MEN
VESTIBULE
WOMEN
VESTIBULE
JANITOR
SHIPPING
RECEIVING
STANDARDS
TESTING
LABORATORY
FOYER
VESTIBULE
BALE PRESS
AIR LOCK
CLASSING OFFICE
RECEIVING
ROOM
STANDARDS
PREPARATION
LABORATORY
STANDARDIZATION
& ENGINEERING
DIVISION
CLASSING
LABORATORY 2
ASSOCIATE
DEPUTY
DIRECTOR
AREA
DIRECTOR
TOOL
ROOM
CLASSING
OFFICE
GRADING
DIVISION
STORAGE
ENGINEERING
STAFF
ASSISTANT
DIVISION
DIRECTOR
CONFERENCE
ROOM
DIVISON
DIRECTOR
ASSISTANT
DIVISON
DIRECTOR
CORRIDOR
DIVISION
DIRECTOR
ASSISTANT
DIVISION
DIRECTOR
138A
ECONOMIST
140A
STORAGE
164A
ASSISTANT
AREA
DIRECTOR
166A
TOOL
ROOM
167A
WAREHOUSE
STORAGE
172 A
ADMINISTRATIVE
STAFF
DIRECTOR
140B
INSTRUMENT
QUALITY
SPECIALIST
138B
FINANCIAL
OFFICER
HSPD 12
A1
LEVELING FLOOR PLAN
1/8"=1'-0"
MATCHLINE
MATCHLINE
M A
T C
H L
I N
E
WAREHOUSE
172 C
M A
T C
H L
I N
E
GENERAL NOTES
A. DRAWING INCLUDES ALL FLOOR PLAN MODIFICATIONS TO DATE;
CONTRACTOR SHALL CONDUCT BUILDING SURVEY TO VERIFY ALL SHOWN
MODIFICATIONS & MAKE NOTE OF ANY MODIFICATIONS NOT SHOWN ON
INCLUDED PLANS
A2
A1
A1
A1
A1
A1
NORTH
ISSUING OFFICE:
NO DESCRIPTIONDATE
PROJECT NO:
KEY PLAN
654321
654321
A
B
C
D
E
LUBBOCK 9382.13
1 01/29/2014 100% ISSUE
A-101A
ATTACHMENT 1: REFERENCE ONLY!
ORIGINAL "ATTACHMENT B" DRAWING FROM FANNING,
FANNING & ASSOCIATES DESCRIBING THE
MECHANICAL PLUMBING AND ELECTRICAL SYSTEMS IN
THE BUILDING AS THEY EXIST CURRENTLY.
File details come from the government source that posted it. Updated .