Exh 6.3_Plan Sheet RD820.pdf

PDF 153 KB Posted

Attached to
ESB I5 Albany ROW Fencing
Solicitation number
S-73000-00018261
Issued by
Oregon

About this file

This file is a technical plan sheet (RD820) from Oregon Standard Drawings used by the Oregon Department of Transportation (ODOT) for fence gate specifications. The document provides detailed engineering specifications and dimensional requirements for both single and double gate installations designed for use with specific fence types (Types 1, 1-5W, and 2). The plan sheet, effective as of the date shown and revised through July 20, 2020, establishes material requirements including Schedule 40 galvanized steel pipe for frames and braces, woven wire fabric or chain link fabric options, and truss rod specifications. Gate opening dimensions range from a maximum of 20 feet for single gates to 40 feet for double gates. The specifications include detailed tables indicating rod numbers, nominal diameters, minimum weights, and brace configurations, with all materials required to comply with current Oregon Standard Specifications and designs prepared in accordance with generally accepted engineering principles under the responsibility of a Registered Professional Engineer.

The technical specifications mandate that gate posts on each side of a gate opening be uniform in size, with maximum taper of one inch in four feet, and reference additional details from Standard Drawing RD810 for end posts, setting, and bracing. The document is associated with the ESB I5 Albany ROW Fencing project, an Oregon state and local contract opportunity requiring an Emerging Small Business certification to submit a bid. This certification requirement represents a set-aside for emerging small businesses in Oregon, positioning the project as restricted to contractors holding this specific qualification for the right-of-way fencing removal, replacement, installation, and new access gate installation work.

View the file

Other files

File Type Posted
Exh 6.2_Plan Sheet RD810.pdf PDF
Exh 5_Specifications~1.docx DOCX document
Att A Form A-2_Bid Pricing Form.xlsx XLSX spreadsheet
00018261_RFCQ.docx DOCX document
Exh 6.1_D4 I5 Albany Refencing location.kml KML file
00018261_Att B_Sample Contract.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RD820

FENCE GATES

R D

.d g n

13-JAN-2020N/A

J U

L

RODS

NUMBERDOUBLE GATESINGLE GATE

Min. Avg.(in)

NOM. DIA.

(in)

NOM. DIA.

DIA. OF SMALL END (in)

(in)

NOM. SIZE

(in)

NOM. DIA.

(lb/ft)

MIN. WT.

(lb/ft)

MIN. WT.

(lb/ft)

MIN. WT.

Max.Min.

17 thru 20

12 thru 16

7 thru 11

UP thru 6

33 thru 40

23 thru 32

13 thru 22

UP thru 12

3.65

2.72

2.27

1.68

2.27

2.27

1.68

10x10

8x8

6x6

6x6

18.97

18.97

9.11

5.79

1 2

Brace(s) to be equally spaced when required (See Table)

Schedule 40 galv. steel pipe brace (Typ.)

(See Table) steel pipe frame

Schedule 40 galv.

two are required)

Truss rod (Where

(See Table)

Gate post

(See Table)

" dia.8

Truss rod, or chain link fabric

Woven wire fabric

(See Table)

Gate post

Finish grade

Gate opening (as shown on plans)

20' single gate

Max. opening 40' double gate

For length, setting and bracing details see end posts, Std. Dwg. RD810.

to be as indicated for single gate installation of the wider gate width.

At a double gate installation with unequal width gates, size of both posts

Gate posts on each side of a gate opening to be the same size.

Max. taper 1" in 4'

4. Add fence grounding as required.

3. See project plans for details not shown.

2. See Std. Dwg. RD810 for details not shown.

1. Gates shown are for use with Fence Types 1, 1-5W and 2.

GENERAL NOTES FOR ALL DETAILS ON THIS SHEET:

GATE POSTS

GATE COMPONENTS

WOOD STEEL

STEEL PIPE BRACE

SCHEDULE 40 GALV.

STEEL PIPE FRAME

SCHEDULE 40 GALV.

(ft)

GATE OPENING ROUND SQUARE

STEEL PIPE

SCHEDULE 40 GALV.

TRUSS

the current Oregon Standard Specifications.

All materials shall be in accordance with

DATE REVISION DESCRIPTION

OREGON STANDARD DRAWINGS

DATE

SDR

BOOK NO.

CALC.

Effective Date: December 1, 2026 - May 31, 2027

Professional Engineer.

first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with

Standard Drawing, while

The selection and use of this

File details come from the government source that posted it. Updated .