This is an Asbestos Survey Building Status Report for Building 8401 at GE79D (Smith Barracks) located at Chaffee Road in Germany. The report documents identified asbestos-containing materials (ACM), presumed asbestos-containing materials (PACM), and non-asbestos-detected materials (NAD) throughout the three-story concrete structure totaling 51,958 square feet, with a re-survey date of February 23, 2024, conducted by Baker Environmental.

The building contains seven identified ACM areas requiring priority assessment: cement corrugated roof (4,000 M2, rating 30, re-survey 2028); floor tiles with mastic (3,200 M2, rating 70, re-survey 2026); wallboard plaster (1,500 M2, rating 70, re-survey 2026); floor tile tan (50 M2, rating 65, re-survey 2028); and three PACM areas including roofing materials and safes (12-8 M2, ratings 13-27, re-survey 2028). Multiple NAD areas with friable or non-friable characteristics include pipe insulation (140-260 M), floor sheeting vinyl (67 M2), fire protection doors (29 each), and ceiling tiles. Laboratory results from multiple surveys between 1993 and 2023 confirm chrysotile asbestos detection in floor tiles (4-5%) and roofing materials (up to 15%). The overall building risk score of 70 assigns Priority II urgency status, indicating re-assessment is required every two years. ACM materials are partially removed in some areas, with conditions ranging from poor to fair. The report emphasizes contacting the Environmental Division before initiating any work activities within the building.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Installation

GE79D - SMITH BARRACKS

Building Number

Building Utilization

AAFES

ASBESTOS SURVEY: BUILDING STATUS REPORT

This report may not be complete. It is vital to contact the Environmental Division before work activities start.

Dieser Bericht ist nicht komplett. Es ist wichtig die Umweltabteilung zu kontaktieren, bevor Arbeiten beginnen.

DSN: 531-3113 CIV:06111435313113

Identified Materials

RECENT RE-SURVEY INFORMATION

Removed Materials

PREVIOUS ASBESTOS SURVEY INFORMATION

Homogenous

Area ID

ACM

Status

Material description Quantity Rating Re-Survey required

8401-14 ACM Cement corrugated roof, black 4000 M2 30 2028

8401-06 ACM Floor tile, tan (20cm x 20cm) 50 M2 65 2028

8401-04 ACM Wallboard, plastered, white 1500 M2 70 2026

8401-02 ACM Floor tiles plus mastic, beige, brown adhesive (30cm x 30cm) 3200 M2 70 2026

8401-13 PACM Roofing material - other, green 12 M2 27 2028

8401-10 PACM Safe 3 EACH 13 2028

8401-19 PACM Cement roofing panels, gray (20cm x 50cm) 8 M2 27 2028

8401-28 NAD Dust Not required

8401-011 NAD Wallboard, plastered 2800 M2 Not required

8401-018 NAD Floor sheeting vinyl, beige, brown adhesive 7 M2 Not required

8401-020 NAD Floor sheeting vinyl, grey/white, black adhesive 45 M2 Not required

8401-022 NAD Floor sheeting vinyl 10 M2 Not required

8401-023 NAD Floor sheeting vinyl, brown, black adhesive 5 M2 Not required

8401-024 NAD Pipe insulation 140 M Not required

8401-025 NAD Pipe insulation, white 260 M Not required

8401-026 NAD Pipe insulation 130 M Not required

8401-03 NAD Fire protection door(s) 29 EACH Not required

8401-005 NAD Floor tile plus mastic, brown (30 X 30 cm) 2 M2 Not required

8401-27 NAD Dust Not required

8401-29 NAD Dust Not required

8401-30 NAD Pipe insulation Not required

8401-31 NAD Ceiling tiles, white Not required

8401-15 NAD Roofing material - other, black 40 M2 Not required

Building status ACM Recommendation - Next Re-Survey 2026

8401-32 R-ACM Floor tile, beige NA Not required

8401-09 R-ACM Floor tile plus mastic, green (20cm x 20cm) 20 M2 NA Not required

Last Survey Date(s) Surveyed by Risk Score Urgency Level

3/3/1993 Baker Env. 1993 74 II

3/19/2009 CH2MHILL 2009-2010 67 III

11/20/2013 DPW In-house 2014 75 II

1/7/2015 DPW In-house Jan 2015 75 II

11/14/2017 Amec Foster Wheeler 70 II

9/18/2019 DPW inhouse 70 II

4/21/2023 Aecom International Inc. 70 II

Building Description / Inaccessible Areas / Narrative

Three story concrete building (PX), with masonry /plastered walls, unused attic, no basement: areas of buildings: 8401(47309sqft), 8401C (1311sqft) , 8401D, 8401E and 8401F

Bldg. Area

51958

Location

Chaffee road m² ft²

Date of Re-Survey

2/23/2024

Re-Surveyed by

Baker Env. 1993

8401-08 R-ACM Floor tiles, plus mastic, gray/beige, brown adhesive (80cm x 80cm)

30 M2 NA Not required

8401-07 R-ACM Floor tile plus mastic, white (20cm x 20cm) 0 NA Not required

8401-21 R-PACM Gasket material 0 NA Not required

8401-17 R-PACM Freezer 0 NA Not required

8401-12 R-PACM Cement corrugated roof 0 NA Not required

Homogenous Area Description

Floor tiles plus mastic, beige, brown adhesive (30cm x 30cm)

201, 203, 205-207, 214

1st floor: 101-104, 107, 109, 109B, 118, Entry,108, 109A, 113-117, 119-124, 133; 2nd fl poor condition, present in break room

Asbestos Status of HA

ACM

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Recommendation

Estimated Quantity

3200 M2

Abatement Status

PARTLY REMOVED

Condition

POOR

Material Friability

LOW

Material Type

Other

Disturbance Potential

HIGH

HIGH

Activity Level

EASY

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-02

Recent Survey Date

2/21/2024

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

70 II

DPW inhouse9/18/2019 70 II

Amec Foster Wheeler11/14/2017 70 II

Baker Env. 19933/3/1993 65 III

CH2MHILL 2009-20103/19/2009 62 III

DPW In-house 20146/11/2014 50 III

Sample ID Sampling

Date

Asbestos detected

Laboratory Results in %

8401-002-AQ4 3/3/1993 ACM 4% CHRYSOTILE

8401-002-A14 3/3/1993 ACM 5% CHRYSOTILE

BH-8401-AS-1 4/21/2023 ACM ACM Detected

I - Type of asbestos use

a. Sprayed-on asbestos

b. Asbestos-containing plaster

c. Lightweight asbestos-containing panels

d. Other asbestos-containing products

II

II - Type of asbestos

a. Amphibole asbestos

b. Other asbestos (white)

III - Surface structure of the asbestos product

a. Highly friable fiber structure

b. Non-friable fiber structure without or with insufficient impermeable coating

c. Coated, impermeable surface

IV - Surface conditon of the asbestos product

a. Severe damages

b. Minor damages

c. No damages

V - External impacts of the asbestos product

a. Product is subjected to impacts via direct access (floor level to arm's reach)

b. Product is worked on occasionally

c. Product is subjected to physical impacts

d. Product is subject to vibrations

e. Product is subjected to severe climatic changes

f. Product is located in an area of strong air currents

g. Strong air currents are present in the room in which the asbestos product is located

h. The product may be subject to abrasion

i. Product is not subject to external impacts

VI - Room use

a. Room is used regularly by children, youth, and athletes

b. Room is used constantly or frequently by other persons

c. Room is used occasionally

d. Room is used rarely

VII - Location of the product

a. Directly in the room

b. In the ventilation for the room (in lining or outher wrapping of non-airtight ducts)

c. Behind a non-airtight suspended ceiling or paneling

d. Behind an airtight suspended ceiling or paneling, outside air-tight went ducts

5, 10 or 15

5, 10, 15 or 20

Abatement analysis Priority I

Priority II

Priority III

Sum of the Assessment Points

≥ 80

70-79

≤ 69

Abatement Required Immediately

Re-Assess every <2 Years

Re-Assess every <5 Years

Asbestos presumed or detected in any of the samples?

This material is assessd as Priority:

ACM

2/21/2024Aecom International Inc.

URGENCY OF ASBESTOS ABATEMENT - ASSESSMENT FORM

Building

LOCATION (BUILDING and ROOM NUMBER)

Material located in/at

201, 203, 205-207, 214

Material removed in/at

1st floor: 101-104, 107, 109, 109B, 118, Entry,108, 109A, 113-117, 119-124, 133; 2nd floor: hallA209, 212, 213

HOMOGENOUS AREA IDMATERIAL DESCRIPTION Floor tiles plus mastic, beige, brown adhesive (30cm x 30cm)

8401-02

Items to assess Point values Assessment points

(Signature, Title and Date of survey)

Wallboard, plastered, white

Entire building, all structural walls

Material identified only in room 118

Asbestos Status of HA

ACM

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Recommendation

Estimated Quantity

1500 M2

Abatement Status

NOT ABATED

Condition

POOR

Material Friability

LOW

Material Type

Other

Disturbance Potential

HIGH

LOW

Activity Level

EASY

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-04

Recent Survey Date

2/23/2024

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

70 II

Baker Env. 19933/3/1993 74 II

DPW In-house 20146/11/2014 72 II

DPW inhouse9/18/2019 70 II

Amec Foster Wheeler11/14/2017 70 II

CH2MHILL 2009-20103/19/2009 67 III

Sample ID Sampling

Date

Asbestos detected

Laboratory Results in %

8401-004-A14 3/3/1993 ACM 2% CHRYSOTILE

8401-04-A 3/19/2009 ACM no Asbestos detected

8401-04-B 3/19/2009 ACM no Asbestos detected

b. Asbestos-containing plaster

c. Lightweight asbestos-containing panels

d. Other asbestos-containing products

II

II - Type of asbestos

a. Amphibole asbestos

b. Other asbestos (white)

III - Surface structure of the asbestos product

a. Highly friable fiber structure

b. Non-friable fiber structure without or with insufficient impermeable coating

c. Coated, impermeable surface

IV - Surface conditon of the asbestos product

a. Severe damages

b. Minor damages

c. No damages

V - External impacts of the asbestos product

a. Product is subjected to impacts via direct access (floor level to arm's reach)

b. Product is worked on occasionally

c. Product is subjected to physical impacts

d. Product is subject to vibrations

e. Product is subjected to severe climatic changes

f. Product is located in an area of strong air currents

g. Strong air currents are present in the room in which the asbestos product is located

h. The product may be subject to abrasion

i. Product is not subject to external impacts

VI - Room use

a. Room is used regularly by children, youth, and athletes

b. Room is used constantly or frequently by other persons

c. Room is used occasionally

d. Room is used rarely

VII - Location of the product

a. Directly in the room

b. In the ventilation for the room (in lining or outher wrapping of non-airtight ducts)

c. Behind a non-airtight suspended ceiling or paneling

d. Behind an airtight suspended ceiling or paneling, outside air-tight went ducts

5, 10 or 15

5, 10, 15 or 20

Abatement analysis Priority I

Priority II

Priority III

Sum of the Assessment Points

≥ 80

70-79

≤ 69

Abatement Required Immediately

Re-Assess every <2 Years

Re-Assess every <5 Years

Asbestos presumed or detected in any of the samples?

This material is assessd as Priority:

(Signature, Title and Date of survey)

ACM

2/23/2024Aecom International Inc.

URGENCY OF ASBESTOS ABATEMENT - ASSESSMENT FORM

Building

LOCATION (BUILDING and ROOM NUMBER)

Material located in/at

Entire building, all structural walls

Material removed in/at

HOMOGENOUS AREA IDMATERIAL DESCRIPTION Wallboard, plastered, white 8401-04

Floor tile, tan (20cm x 20cm)

2nd floor: hall A, hall B

1st floor: 101, 103, 104, 102

Floor tiles beige

Asbestos Status of HA

ACM

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Recommendation

Estimated Quantity

50 M2

Abatement Status

PARTLY REMOVED

Condition

POOR

Material Friability

LOW

Material Type

Other

Disturbance Potential

HIGH

MEDIUM

Activity Level

EASY

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-06

Recent Survey Date

4/21/2023

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

65 III

DPW In-house Jan 20151/7/2015 75 II

DPW In-house 20146/11/2014 67 III

Baker Env. 19933/3/1993 65 III

Amec Foster Wheeler5/14/2017 65 III

CH2MHILL 2009-20103/19/2009 62 III

Sample ID Sampling

Date

Asbestos detected

Laboratory Results in %

8401-006-A14 3/3/1993 ACM 3% CHRYSOTILE

b. Asbestos-containing plaster

c. Lightweight asbestos-containing panels

d. Other asbestos-containing products

III

II - Type of asbestos

a. Amphibole asbestos

b. Other asbestos (white)

III - Surface structure of the asbestos product

a. Highly friable fiber structure

b. Non-friable fiber structure without or with insufficient impermeable coating

c. Coated, impermeable surface

IV - Surface conditon of the asbestos product

a. Severe damages

b. Minor damages

c. No damages

V - External impacts of the asbestos product

a. Product is subjected to impacts via direct access (floor level to arm's reach)

b. Product is worked on occasionally

c. Product is subjected to physical impacts

d. Product is subject to vibrations

e. Product is subjected to severe climatic changes

f. Product is located in an area of strong air currents

g. Strong air currents are present in the room in which the asbestos product is located

h. The product may be subject to abrasion

i. Product is not subject to external impacts

VI - Room use

a. Room is used regularly by children, youth, and athletes

b. Room is used constantly or frequently by other persons

c. Room is used occasionally

d. Room is used rarely

VII - Location of the product

a. Directly in the room

b. In the ventilation for the room (in lining or outher wrapping of non-airtight ducts)

c. Behind a non-airtight suspended ceiling or paneling

d. Behind an airtight suspended ceiling or paneling, outside air-tight went ducts

5, 10 or 15

5, 10, 15 or 20

Abatement analysis Priority I

Priority II

Priority III

Sum of the Assessment Points

≥ 80

70-79

≤ 69

Abatement Required Immediately

Re-Assess every <2 Years

Re-Assess every <5 Years

Asbestos presumed or detected in any of the samples?

This material is assessd as Priority:

(Signature, Title and Date of survey)

ACM

4/21/2023Aecom International Inc.

URGENCY OF ASBESTOS ABATEMENT - ASSESSMENT FORM

Building

LOCATION (BUILDING and ROOM NUMBER)

Material located in/at

2nd floor: hall A, hall B

Material removed in/at

1st floor: 101, 103, 104, 102

HOMOGENOUS AREA IDMATERIAL DESCRIPTION Floor tile, tan (20cm x 20cm) 8401-06

Cement corrugated roof, black

Roof of main building

Asbestos Status of HA

ACM

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Recommendation

Estimated Quantity

4000 M2

Abatement Status

NOT ABATED

Condition

FAIR

Material Friability

LOW

Material Type

Other

Disturbance Potential

LOW

LOW

Activity Level

DIFFICULT

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-14

Recent Survey Date

4/21/2023

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

30 III

CH2MHILL 2009-20103/19/2009 55 III

DPW In-house 20146/11/2014 35 III

Amec Foster Wheeler11/14/2017 35 III

Baker Env. 19933/3/1993 23 III

Sample ID Sampling

Date

Asbestos detected

Laboratory Results in %

8401-14-A 3/19/2009 ACM up to 15% Chrysotile-Asbestos detected

8401-14-B 3/19/2009 ACM up to 15% Chrysotile-Asbestos detected

b. Asbestos-containing plaster

c. Lightweight asbestos-containing panels

d. Other asbestos-containing products

III

II - Type of asbestos

a. Amphibole asbestos

b. Other asbestos (white)

III - Surface structure of the asbestos product

a. Highly friable fiber structure

b. Non-friable fiber structure without or with insufficient impermeable coating

c. Coated, impermeable surface

IV - Surface conditon of the asbestos product

a. Severe damages

b. Minor damages

c. No damages

V - External impacts of the asbestos product

a. Product is subjected to impacts via direct access (floor level to arm's reach)

b. Product is worked on occasionally

c. Product is subjected to physical impacts

d. Product is subject to vibrations

e. Product is subjected to severe climatic changes

f. Product is located in an area of strong air currents

g. Strong air currents are present in the room in which the asbestos product is located

h. The product may be subject to abrasion

i. Product is not subject to external impacts

VI - Room use

a. Room is used regularly by children, youth, and athletes

b. Room is used constantly or frequently by other persons

c. Room is used occasionally

d. Room is used rarely

VII - Location of the product

a. Directly in the room

b. In the ventilation for the room (in lining or outher wrapping of non-airtight ducts)

c. Behind a non-airtight suspended ceiling or paneling

d. Behind an airtight suspended ceiling or paneling, outside air-tight went ducts

5, 10 or 15

5, 10, 15 or 20

Abatement analysis Priority I

Priority II

Priority III

Sum of the Assessment Points

≥ 80

70-79

≤ 69

Abatement Required Immediately

Re-Assess every <2 Years

Re-Assess every <5 Years

Asbestos presumed or detected in any of the samples?

This material is assessd as Priority:

(Signature, Title and Date of survey)

ACM

4/21/2023Aecom International Inc.

URGENCY OF ASBESTOS ABATEMENT - ASSESSMENT FORM

Building

LOCATION (BUILDING and ROOM NUMBER)

Material located in/at

Roof of main building

Material removed in/at

HOMOGENOUS AREA IDMATERIAL DESCRIPTION Cement corrugated roof, black 8401-14

Roofing material - other, green

Roof above 105,HD-S 1+2,3A,4

Asbestos Status of HA

PACM

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Recommendation

Estimated Quantity

12 M2

Abatement Status

NOT ABATED

Condition

GOOD

Material Friability

LOW

Material Type

Other

Disturbance Potential

LOW

LOW

Activity Level

DIFFICULT

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-13

Recent Survey Date

4/21/2023

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

27 III

CH2MHILL 2009-20103/19/2009 30 III

Amec Foster Wheeler11/14/2017 27 III

DPW In-house 20146/11/2014 24 III

Baker Env. 19933/3/1993 23 III

b. Asbestos-containing plaster

c. Lightweight asbestos-containing panels

d. Other asbestos-containing products

III

II - Type of asbestos

a. Amphibole asbestos

b. Other asbestos (white)

III - Surface structure of the asbestos product

a. Highly friable fiber structure

b. Non-friable fiber structure without or with insufficient impermeable coating

c. Coated, impermeable surface

IV - Surface conditon of the asbestos product

a. Severe damages

b. Minor damages

c. No damages

V - External impacts of the asbestos product

a. Product is subjected to impacts via direct access (floor level to arm's reach)

b. Product is worked on occasionally

c. Product is subjected to physical impacts

d. Product is subject to vibrations

e. Product is subjected to severe climatic changes

f. Product is located in an area of strong air currents

g. Strong air currents are present in the room in which the asbestos product is located

h. The product may be subject to abrasion

i. Product is not subject to external impacts

VI - Room use

a. Room is used regularly by children, youth, and athletes

b. Room is used constantly or frequently by other persons

c. Room is used occasionally

d. Room is used rarely

VII - Location of the product

a. Directly in the room

b. In the ventilation for the room (in lining or outher wrapping of non-airtight ducts)

c. Behind a non-airtight suspended ceiling or paneling

d. Behind an airtight suspended ceiling or paneling, outside air-tight went ducts

5, 10 or 15

5, 10, 15 or 20

Abatement analysis Priority I

Priority II

Priority III

Sum of the Assessment Points

≥ 80

70-79

≤ 69

Abatement Required Immediately

Re-Assess every <2 Years

Re-Assess every <5 Years

Asbestos presumed or detected in any of the samples?

This material is assessd as Priority:

(Signature, Title and Date of survey)

PACM

4/21/2023Aecom International Inc.

URGENCY OF ASBESTOS ABATEMENT - ASSESSMENT FORM

Building

LOCATION (BUILDING and ROOM NUMBER)

Material located in/at

Roof above 105,HD-S 1+2,3A,4

Material removed in/at

HOMOGENOUS AREA IDMATERIAL DESCRIPTION Roofing material - other, green 8401-13

Cement roofing panels, gray (20cm x 50cm)

Roof chimney panels

Asbestos Status of HA

PACM

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Recommendation

Estimated Quantity

8 M2

Abatement Status

NOT ABATED

Condition

FAIR

Material Friability

LOW

Material Type

Other

Disturbance Potential

LOW

LOW

Activity Level

DIFFICULT

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-19

Recent Survey Date

4/21/2023

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

27 III

CH2MHILL 2009-20103/19/2009 30 III

DPW In-house 20146/11/2014 27 III

Amec Foster Wheeler11/14/2017 27 III

Baker Env. 19933/3/1993 23 III

b. Asbestos-containing plaster

c. Lightweight asbestos-containing panels

d. Other asbestos-containing products

III

II - Type of asbestos

a. Amphibole asbestos

b. Other asbestos (white)

III - Surface structure of the asbestos product

a. Highly friable fiber structure

b. Non-friable fiber structure without or with insufficient impermeable coating

c. Coated, impermeable surface

IV - Surface conditon of the asbestos product

a. Severe damages

b. Minor damages

c. No damages

V - External impacts of the asbestos product

a. Product is subjected to impacts via direct access (floor level to arm's reach)

b. Product is worked on occasionally

c. Product is subjected to physical impacts

d. Product is subject to vibrations

e. Product is subjected to severe climatic changes

f. Product is located in an area of strong air currents

g. Strong air currents are present in the room in which the asbestos product is located

h. The product may be subject to abrasion

i. Product is not subject to external impacts

VI - Room use

a. Room is used regularly by children, youth, and athletes

b. Room is used constantly or frequently by other persons

c. Room is used occasionally

d. Room is used rarely

VII - Location of the product

a. Directly in the room

b. In the ventilation for the room (in lining or outher wrapping of non-airtight ducts)

c. Behind a non-airtight suspended ceiling or paneling

d. Behind an airtight suspended ceiling or paneling, outside air-tight went ducts

5, 10 or 15

5, 10, 15 or 20

Abatement analysis Priority I

Priority II

Priority III

Sum of the Assessment Points

≥ 80

70-79

≤ 69

Abatement Required Immediately

Re-Assess every <2 Years

Re-Assess every <5 Years

Asbestos presumed or detected in any of the samples?

This material is assessd as Priority:

(Signature, Title and Date of survey)

PACM

4/21/2023Aecom International Inc.

URGENCY OF ASBESTOS ABATEMENT - ASSESSMENT FORM

Building

LOCATION (BUILDING and ROOM NUMBER)

Material located in/at

Roof

Material removed in/at

HOMOGENOUS AREA IDMATERIAL DESCRIPTION Cement roofing panels, gray (20cm x 50cm) 8401-19

Safe

2nd floor: 215

102, 126, 209, 109, 125A, interior insulation, metal enclosed

Asbestos Status of HA

PACM

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Recommendation

Estimated Quantity

3 EACH

Abatement Status

PARTLY REMOVED

Condition

FAIR

Material Friability

Material Type

TSI-Other

Disturbance Potential

LOW

MEDIUM

Activity Level

DIFFICULT

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-10

Recent Survey Date

4/21/2023

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

13 III

CH2MHILL 2009-20103/19/2009 60 III

Baker Env. 19933/3/1993 25 III

DPW In-house 20146/11/2014 13 III

Amec Foster Wheeler11/14/2017 13 III

b. Asbestos-containing plaster

c. Lightweight asbestos-containing panels

d. Other asbestos-containing products

III

II - Type of asbestos

a. Amphibole asbestos

b. Other asbestos (white)

III - Surface structure of the asbestos product

a. Highly friable fiber structure

b. Non-friable fiber structure without or with insufficient impermeable coating

c. Coated, impermeable surface

IV - Surface conditon of the asbestos product

a. Severe damages

b. Minor damages

c. No damages

V - External impacts of the asbestos product

a. Product is subjected to impacts via direct access (floor level to arm's reach)

b. Product is worked on occasionally

c. Product is subjected to physical impacts

d. Product is subject to vibrations

e. Product is subjected to severe climatic changes

f. Product is located in an area of strong air currents

g. Strong air currents are present in the room in which the asbestos product is located

h. The product may be subject to abrasion

i. Product is not subject to external impacts

VI - Room use

a. Room is used regularly by children, youth, and athletes

b. Room is used constantly or frequently by other persons

c. Room is used occasionally

d. Room is used rarely

VII - Location of the product

a. Directly in the room

b. In the ventilation for the room (in lining or outher wrapping of non-airtight ducts)

c. Behind a non-airtight suspended ceiling or paneling

d. Behind an airtight suspended ceiling or paneling, outside air-tight went ducts

5, 10 or 15

5, 10, 15 or 20

Abatement analysis Priority I

Priority II

Priority III

Sum of the Assessment Points

≥ 80

70-79

≤ 69

Abatement Required Immediately

Re-Assess every <2 Years

Re-Assess every <5 Years

Asbestos presumed or detected in any of the samples?

This material is assessd as Priority:

(Signature, Title and Date of survey)

PACM

4/21/2023Aecom International Inc.

URGENCY OF ASBESTOS ABATEMENT - ASSESSMENT FORM

Building

LOCATION (BUILDING and ROOM NUMBER)

Material located in/at

2nd floor: 215

Material removed in/at

102, 126, 209, 109, 125A, HOMOGENOUS AREA IDMATERIAL DESCRIPTION Safe 8401-10

Fire protection door(s)

1st and 2nd floor: all doors but office doors

Although the samples of the fire doors have been analyzed to be NAD, it cannot be excluded that another fire door may contain asbestos. Therefore O&M is still recommended.

Asbestos Status of HA

NAD

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Not required

O&M

Recommendation

Estimated Quantity

29 EACH

Abatement Status

NOT ABATED

Condition

FAIR

Material Friability

HIGH

Material Type

TSI-Other

Disturbance Potential

HIGH

HIGH

Activity Level

MEDIUM

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-03

Recent Survey Date

3/19/2009

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

Baker Env. 19933/3/1993 30 III

Sample ID Sampling

Date

Asbestos detected

8401-03-A 3/19/2009 NAD no Asbestos detected

Roofing material - other, black

Roof above 106, east end, VD-S 1-1,1-2,2,3

Asbestos Status of HA

NAD

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Not required

None

Recommendation

Estimated Quantity

40 M2

Abatement Status

NOT ABATED

Condition

FAIR

Material Friability

LOW

Material Type

Other

Disturbance Potential

LOW

LOW

Activity Level

DIFFICULT

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-15

Recent Survey Date

3/19/2009

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

Baker Env. 19933/3/1993 23 III

Sample ID Sampling

Date

Asbestos detected

8401-15-A 3/19/2009 NAD no Asbestos detected

Floor tile plus mastic, brown (30 X 30 cm)

1ST, PX, ROOM 101, 109

USED AS REPLACEMENT IN ROOM 101, 109

Asbestos Status of HA

NAD

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Not required

O&M

Recommendation

Estimated Quantity

2 M2

Abatement Status

Condition

Material Friability

NONFRIABLE

Material Type

Disturbance Potential

Activity Level

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-005

Recent Survey Date

3/3/1993

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

Sample ID Sampling

Date

Asbestos detected

Laboratory Results in %

8401-005-A14 3/3/1993 NAD No Asbestos Detected

8401-005-B14 3/3/1993 NAD No Asbestos Detected

Wallboard, plastered

1ST, PX, ENTIRE BUILDING, ALL NONSTRUCTURAL WALLS AND STRUCTURAL

OF ROOM 113

Asbestos Status of HA

NAD

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Not required

O&M

Recommendation

Estimated Quantity

2800 M2

Abatement Status

Condition

Material Friability

NONFRIABLE

Material Type

Disturbance Potential

Activity Level

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-011

Recent Survey Date

3/3/1993

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

Sample ID Sampling

Date

Asbestos detected

Laboratory Results in %

8401-011-A14 3/3/1993 NAD No Asbestos Detected

8401-011-B14 3/3/1993 NAD No Asbestos Detected

Floor sheeting vinyl, beige, brown adhesive

1ST, VENDING AREA, ROOM 134

Asbestos Status of HA

NAD

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Not required

O&M

Recommendation

Estimated Quantity

7 M2

Abatement Status

Condition

Material Friability

NONFRIABLE

Material Type

Disturbance Potential

Activity Level

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-018

Recent Survey Date

3/3/1993

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

Sample ID Sampling

Date

Asbestos detected

Laboratory Results in %

8401-018-A14 3/3/1993 NAD No Asbestos Detected

8401-018-B14 3/3/1993 NAD No Asbestos Detected

Floor sheeting vinyl, grey/white, black adhesive

2ND, OFFICES, ROOMS 202, 204

Asbestos Status of HA

NAD

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Not required

O&M

Recommendation

Estimated Quantity

45 M2

Abatement Status

Condition

Material Friability

NONFRIABLE

Material Type

Disturbance Potential

Activity Level

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-020

Recent Survey Date

3/3/1993

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

Sample ID Sampling

Date

Asbestos detected

Laboratory Results in %

8401-020-A14 3/3/1993 NAD No Asbestos Detected

8401-020-B14 3/3/1993 NAD No Asbestos Detected

Floor sheeting vinyl

3RD, OFFICE, 301

Asbestos Status of HA

NAD

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Not required

O&M

Recommendation

Estimated Quantity

10 M2

Abatement Status

Condition

Material Friability

NONFRIABLE

Material Type

Disturbance Potential

Activity Level

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-022

Recent Survey Date

3/3/1993

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

Sample ID Sampling

Date

Asbestos detected

Laboratory Results in %

8401-022-A14 3/3/1993 NAD No Asbestos Detected

8401-022-B14 3/3/1993 NAD No Asbestos Detected

Floor sheeting vinyl, brown, black adhesive

3RD, OFFICE, ROOM 301

Asbestos Status of HA

NAD

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Not required

O&M

Recommendation

Estimated Quantity

5 M2

Abatement Status

Condition

Material Friability

NONFRIABLE

Material Type

Disturbance Potential

Activity Level

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-023

Recent Survey Date

3/3/1993

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

Sample ID Sampling

Date

Asbestos detected

Laboratory Results in %

8401-023-A14 3/3/1993 NAD No Asbestos Detected

8401-023-B14 3/3/1993 NAD No Asbestos Detected

Pipe insulation

ATTIC, 1ST, ATTIC, ATTIC AREA, 1ST, 2ND, 3RD

Asbestos Status of HA

NAD

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Not required

REPLACE

Recommendation

Estimated Quantity

140 M

Abatement Status

Condition

Material Friability

FRIABLE

Material Type

Disturbance Potential

Activity Level

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-024

Recent Survey Date

3/3/1993

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

Sample ID Sampling

Date

Asbestos detected

Laboratory Results in %

8401-024-A14 3/3/1993 NAD No Asbestos Detected

8401-024-B14 3/3/1993 NAD No Asbestos Detected

8401-024-C14 3/3/1993 NAD No Asbestos Detected

Pipe insulation, white

1ST, WAREHOUSE/HEATING, HEATING, MECHANICAL HALL, HALL 107, 106

Asbestos Status of HA

NAD

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Not required

REPLACE

Recommendation

Estimated Quantity

260 M

Abatement Status

Condition

Material Friability

FRIABLE

Material Type

Disturbance Potential

Activity Level

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-025

Recent Survey Date

3/3/1993

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

Sample ID Sampling

Date

Asbestos detected

Laboratory Results in %

8401-025-A14 3/3/1993 NAD No Asbestos Detected

8401-025-B14 3/3/1993 NAD No Asbestos Detected

8401-025-C14 3/3/1993 NAD No Asbestos Detected

2ND, PX, AIR HANDLING, ABOVE ROOM 113

Asbestos Status of HA

NAD

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Not required

O&M

Recommendation

Estimated Quantity

130 M

Abatement Status

Condition

Material Friability

NONFRIABLE

Material Type

Disturbance Potential

Activity Level

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-026

Recent Survey Date

3/3/1993

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

Sample ID Sampling

Date

Asbestos detected

Laboratory Results in %

8401-026-A14 3/3/1993 NAD No Asbestos Detected

8401-026-B14 3/3/1993 NAD No Asbestos Detected

8401-026-C14 3/3/1993 NAD No Asbestos Detected

Dust

Dust on stairs in storage

Dust on stair string

Asbestos Status of HA

NAD

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Not required

Recommendation

Estimated Quantity

Abatement Status

Condition

Material Friability

Material Type

Disturbance Potential

Activity Level

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-27

Recent Survey Date

11/20/2013

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

Sample ID Sampling

Date

Asbestos detected

8401-27 11/20/2013 NAD No asbestos detected

Dust on pipes in storage

Dust on heating pipe in storage area

Asbestos Status of HA

NAD

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Not required

Material Friability

Material Type

Disturbance Potential

Activity Level

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-28

Recent Survey Date

11/20/2013

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

Sample ID Sampling

Date

Asbestos detected

8401-28 11/20/2013 NAD No asbestos detected

Floor next to stairs

Dust on floor next to stairs

Asbestos Status of HA

NAD

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Not required

Material Friability

Material Type

Disturbance Potential

Activity Level

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-29

Recent Survey Date

11/20/2013

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

Sample ID Sampling

Date

Asbestos detected

8401-29 11/20/2013 NAD No asbestos detected

Above entrance to storage area

Fibres and cement tested

Asbestos Status of HA

NAD

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Not required

Material Friability

Material Type

Disturbance Potential

Activity Level

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-30

Recent Survey Date

11/20/2013

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

Sample ID Sampling

Date

Asbestos detected

8401-30 11/20/2013 NAD No asbestos detected

Ceiling tiles, white

Storage area, second floor

Asbestos Status of HA

NAD

RECENT HA SURVEY INFORMATION

Comments

Homogenous Area Location present:

removed:

Re-Survey required

Not required

Material Friability

Material Type

Disturbance Potential

Activity Level

Accessibility

ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT

Installation

GE79D - SMITH BARRACKS

Building Number

Homogenous Area

8401-31

Recent Survey Date

11/20/2013

Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level

PREVIOUS HA SURVEY INFORMATION

Laboratory Results

Risk Score / Urgency Level

Sample ID Sampling

Date

Asbestos detected

8401-31 11/20/2013 NAD No asbestos detected