Plaza Verde Building 3 HVAC Replacement Project - Contract Documents Summary

These are project drawings and contract documents for the Plaza Verde Building 3 HVAC Replacement project at Angelo State University, located at 2010 S Van Buren Street, San Angelo, Texas 76904. The project involves the complete replacement of the heating, ventilation, and air conditioning systems in a 3-story, 36-foot-tall dormitory building containing approximately 33,660 gross square feet (11,280 square feet per floor renovation area). The scope of work includes demolition of existing HVAC equipment, ductwork, refrigerant piping, and condensate systems, along with installation of new fan coil units, mini-split systems, condensing units, and associated mechanical infrastructure. The building is classified as occupancy type Group R-2 (dormitory) with construction type IIB and is sprinklered. The project is subject to the 2021 International Building Code, 2021 International Mechanical Code, 2021 International Energy Conservation Code, and applicable amendments adopted by the City of San Angelo as of May 18, 2026. The contract documents indicate a project number of 2574.02 with a document date of July 24, 2026, prepared by O'Connell Robertson with Engineering Firm Registration No. F-2708.

The drawings include comprehensive architectural, mechanical, electrical, and structural plans detailing the complete demolition and replacement scope. Architectural plans document the removal of existing carpet flooring, wall base, gypsum board ceilings, and shaft walls, along with room finish specifications using paint designations and carpet tiles. Mechanical plans specify the demolition and new installation of approximately 30 fan coil units, two heat recovery units, two mini-split condensing units, new ductwork routing, and exhaust fan systems with balancing requirements. The contractor is responsible for all permits, fees, inspections, protective dust partitions, firestopping of penetrations, maintaining occupied spaces, and coordination with the owner regarding infectious control measures and utility shutdowns requiring 72 hours' advance notice. Support facilities include a structural engineer (SKG Engineering, 811 Barton Springs Road, Suite 900, Austin, Texas 78704) and architectural-engineering team (2601 W Ave N, San Angelo, Texas 76909), with the engineering firm providing structural analysis and roof penetration details to verify equipment weight and footprint compatibility with existing conditions.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Structural Engineer

706 SOUTH ABE ST

SAN ANGELO , TEXAS 76903

SKG ENGINEERING

811 BARTON SPRINGS ROAD, SUITE 900

AUSTIN, TEXAS 78704

Architecture - Engineering - Interiors

2601 W AVE N

SAN ANGELO , TEXAS 76909

ANGELO STATE UNIVERSITY

Revisions:

Engineering Firm:

O'CONNELL ROBERTSON

Firm Registration No. F-2708

A u st in

S a n A n to n io

H o u s to n

B a rt o n

S p ri n g s

R o a d

S u it e

A u st in Te xa s

B ro a d w a y S u it e

S a n A n to n io

Te xa s

F a n n in

S tr e e t, S u it e

H o u st o n Te xa s p

.4

.7 f

.4

.7 p

.2

.6 f

.2

.6 p

.4

.1 f

.4

.1

A u to d e s k D o c s /A n g e lo S ta te

U n iv e rs it y /2

A S

U P la z a V e rd e B ld g

-H V

A C

R p lm n t_

M E

P C e n tr a l.

rv t

/2

/2

:5

:4

P

M

P L

A Z

A V

E R

D E

B L

D G

H

V A

C R

E P

L A

C E

M E

N T

S

S V

A N

B U

R E N

S T, S A

N A

N G

E

LO

TX

A N

G E

LO

S

TA

TE

U

N

IV

E R

S

IT

Y

PLAZA VERDE BLDG 3 HVAC REPLACEMENTS

2010 S VAN BUREN ST, SAN ANGELO, TX 76904

07/24/26

CONTRACT DOCUMENTS

Mission: We believe every project has a mission and strive to design environments that have a purpose that extend far beyond form and function.

07/24/26

Project No. 2574.02

CONTRACT DOCUMENTS

COVER SHEET

G1.0

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

TAS COMPLIANCE NOTE:

THIS PROJECT DOES NOT QUALIFY AS AN ALTERATION

PER TAS 106.5.5.

Drawing Index

Sheet Number Sheet Name

GENERAL

G1.0 COVER SHEET

G1.1 ARCHITECTURAL ABBREVIATIONS AND SYMBOLS

STRUCTURAL

S1.1 ROOF FRAMING PLAN

ARCHITECTURAL

A2.1 DEMOLITION FLOOR PLANS - LEVELS 1 & 2

A2.2 DEMOLITION FLOOR PLANS - LEVEL 3 & ROOF

A2.3 DEMOLITION REFLECTED CEILING PLANS - LEVELS 1 & 2

A2.4 DEMOLITION REFLECTED CEILING PLAN - LEVEL 3

A3.5 ROOF PLAN

A6.1 EXTERIOR DETAILS

A6.2 EXTERIOR DETAILS

A9.1 REFLECTED CEILING PLAN

A9.2 REFLECTED CEILING PLAN

A10.1 ROOM FINISH PLAN

A10.2 ROOM FINISH PLAN

MECHANICAL

M1.1 MECHANICAL NOTES, SYMBOLS AND ABBREVIATIONS

M2.1 FIRST & SECOND FLOOR MECHANICAL DEMOLITION PLANS

M2.2 THIRD FLOOR & ROOF MECHANICAL DEMOLITION PLANS

M3.1 FIRST & SECOND FLOOR MECHANICAL PLANS

M3.2 THIRD FLOOR & ROOF MECHANICAL PLANS

M7.1 MECHANICAL CONTROLS

M8.1 MECHANICAL SCHEDULES

M9.1 MECHANICAL DETAILS

ELECTRICAL

E1.1 ELECTRICAL NOTES, SYMBOLS AND ABBREVIATIONS

E2.1 FIRST & SECOND FLOOR ELECTRICAL DEMOLITION PLANS

E2.2 THIRD FLOOR & ROOF ELECTRICAL DEMOLITION PLANS

E3.1 FIRST & SECOND FLOOR ELECTRICAL POWER PLANS

E3.2 THIRD FLOOR & ROOF ELECTRICAL POWER PLANS

E4.1 FIRST & SECOND FLOOR LIGHTING PLANS

E4.2 THIRD FLOOR LIGHTING PLAN

E6.1 ELECTRICAL ENLARGED PLANS

E7.1 ELECTRICAL ONE-LINE DIAGRAM

E8.1 ELECTRICAL SCHEDULES

E8.2 ELECTRICAL SCHEDULES

E8.3 ELECTRICAL SCHEDULES

E9.1 ELECTRICAL DETAILS

2 RCP DETAILS

NO. DESCRIPTION DATENO. DESCRIPTION DATE

07/24/2026

1. GENERAL NOTES APPLY TO ALL SHEETS.

2. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS,

TOOLS, EQUIPMENT, AND RELATED ITEMS REQUIRED TO

COMPLETE THE DEMOLITION WORK AS INDICATED BY THE

CONTRACT DOCUMENTS.

3. CONTRACTOR TO VERIFY ALL DIMENSIONS.

4. ALL ACCESSIBLE ROUTES (OTHER THAN RAMPS) SHALL NOT

EXCEED A SLOPE OF 1:20, AND CROSS SLOPES SHALL NOT

EXCEED A SLOPE OF 1:50

5. THE DRAWINGS INDICATE BUILDING CONDITIONS PER

EXISTING DRAWINGS AND ACTUAL PROJECT

INVESTIGATION. THE CONTRACTOR SHALL ANTICIPATE

POSSIBLE SLIGHT DEVIATION FROM THESE DRAWINGS.

REFER TO ARCHITECTURAL & MEP DRAWINGS AND DETAILS

FOR EXTENT OF DEMOLITION.

6. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE

WORK, USING THEIR BEST SKILL AND ATTENTION. THEY

SHALL BE SOLELY RESPONSIBLE FOR ALL MEANS,

METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES

AND FOR COORDINATING ALL PORTIONS OF THE WORK

UNDER THE CONTRACT.

7. INSTALL TEMPORARY DUST PARTITIONS WITH DOORS FOR

CONSTRUCTION ACCESS AROUND AREAS OF WORK SO

THAT OPERATIONS IN EXISTING ADJACENT AREAS REMAIN

DUST FREE AND ACCESSIBLE TO BUILDING OCCUPANTS.

MAINTAIN IN PLACE UNTIL COMPLETION OF CONSTRUCTION.

8. REMOVE ALL BUILDING PARTS AND/OR OTHER ITEMS TO

ALLOW FOR THE INSTALLATION AND CONNECTION OF NEW

WORK, COORDINATE THE WORK WITH THE HVAC,

PLUMBING AND ELECTRICAL DEMOLITION DRAWINGS.

9. REMOVAL OF THE BUILDING PARTS SHALL BE PERFORMED

IN A SAFE, ORDERLY AND CAREFUL MANNER, WITH THE

CONSIDERATION AT ALL TIMES FOR THE SAFETY AND

WELFARE OF THE OWNER, BLDG. OCCUPANTS, &

PERSONNEL OF THE CONTRACTOR AND/OR

SUBCONTRACTOR.

10. MAINTAIN THE UTILITIES TO OCCUPIED SPACES AT ALL

TIMES. COORDINATE ANY UTILITY DOWNTIMES W/ OWNER.

PROVIDE 72 HOUR ADVANCE NOTICE TO THE OWNER OF

INTENDED UTILITY SHUT DOWN AND/OR DISRUPTION.

11. ANY QUESTIONS CONCERNING OWNERSHIP OF

SALVAGEABLE MATERIAL SHALL BE ANSWERED BY THE

OWNER, OR OWNER'S REPRESENTATIVE. ALL ITEMS OTHER

THAN FINISH MATERIALS TO BE REMOVED AS PART OF THIS

CONTRACT ARE INDICATED WITH DASHED LINES ON

DEMOLITION SHEETS. DISPOSE OF THESE MATERIALS AND

ITEMS AFTER CHECKING WITH OWNER FOR ITEMS TO BE

SALVAGED. SALVAGE ANY ITEMS REQUIRED TO COMPLETE

NEW WORK.

12. REMOVE ALL MISCELLANEOUS DEVICES AS REQUIRED TO

INSTALL NEW FINISHES, INCLUDING BUT NOT LIMITED TO:

PLUMBING FIXTURES, SIGNAGE, SWITCH PLATES,

TELEVISION BRACKETS, WALL OUTLET COVERS, TOILET

ACCESSORIES, CORNER GUARDS, ETC. SAVE FOR

REINSTALLATION AFTER COMPLETION OF FINISH WORK.

13. PROTECT ALL EXISTING FINISHES, DOOR FRAMES,

EQUIPMENT AND MATERIALS THAT ARE TO REMAIN IN

PLACE. DAMAGE TO EXISTING COMPONENTS BY

CONTRACTOR SHALL BE REPLACED WITH NEW MATERIAL

OF LIKE KIND AND QUALITY THAT MATCH THE EXISTING

STANDARDS. THE CONTRACTOR IS RESPONSIBLE FOR

PREPARING EXISTING SURFACES TO RECEIVE NEW

FINISHES SCHEDULED.

14. PROTECT EXISTING VEGETATION, INCLUDING EXISTING

TREES DURING CONSTRUCTION. REVEGETATE DAMAGED

AREAS ADJACENT TO NEW CONSTRUCTION; CONTRACTOR

SHALL MAINTAIN VEGETATED AREAS FOR 3 WEEKS AFTER

INITIAL PLANTING

15. REFER TO MECHANICAL, PLUMBING AND ELECTRICAL

DRAWINGS FOR OTHER WORK.

16. ELECTRICAL AND MECHANICAL INSTALLATIONS MAY

REQUIRE WORK ABOVE EXISTING CEILINGS BOTH IN THE

AREA OF WORK AND IN ADJACENT AREAS (POSSIBLY ON

OTHER FLOORS). REMOVE AND REINSTALL (OR REPLACE)

CEILING TILES AND GRID AS REQUIRED. REMOVE GYPSUM

BOARD AT WALLS AND CEILINGS AND REPLACE AS

REQUIRED.

17. U.N.O. ALL EXISTING ELECTRICAL OUTLETS & FIXTURES IN

REMODELED AREAS ARE TO BE REMOVED & RETURNED TO

OWNER. SEE ELECTRICAL SHEETS FOR DEVICES &

CIRCUITS TO BE REUSED.

18. ALL ITEMS AND ASSOCIATED CONNECTIONS ARE TO BE

REMOVED AND TERMINATED AT DESIGNATED POINTS.

SERVICE CONNECTIONS SHALL BE SAFELY REMOVED,

CAPPED OR PLUGGED IN CONFORMITY WITH LOCAL LAWS

AND ORDINANCES, REQUIREMENTS OF PUBLIC UTILITY

COMPANIES, AND OF THE NATIONAL BOARD OF FIRE

UNDERWRITERS, AND IN SUCH MANNER AS NOT TO

INTERFERE WITH THE USE OF THE OCCUPIED SPACES IN

THE BUILDING.

19. IF A CONDUIT OR UTILITY LINE IS CUT WHILE SLEEVING OR

CUTTING THE SLAB OR REMOVING A PARTITION, THE

CONTRACTOR IS RESPONSIBLE FOR REPAIRING IT

IMMEDIATELY.

20. ANY EXISTING TO REMAIN FIREPROOFING OR FIRE

ASSEMBLIES DAMAGED DURING CONSTRUCTION ARE TO BE

REPAIRED TO ORIGINAL FIRE PROTECTION REQUIREMENTS.

21. IMMEDIATELY SEAL ALL PENETRATIONS IN EXISTING

STRUCTURE OPENED DURING DEMOLITION WITH

FIRESTOPPING MATERIAL AND/OR WATERPROOFING.

22. SEAL ALL PENETRATIONS, NEW AND EXISTING, ABOVE

CEILINGS AT RATED FIRE WALLS IN AREAS OF WORK.

COUNTER MOUNTED DROP-IN SINK

COUNTER MOUNTED UNDER

MOUNT SINK

COUNTER MOUNTED INTEGRAL

SINK

WALL MOUNTED SINK

FLOOR MOUNTED TOILET

WALL MOUNTED TOILET

FLOOR MOUNTED REAR DISCHARGE

TOILET

ACCESSIBLE LOCATION

USE ON PLANS EXAMPLE

WALL MOUNTED URINAL

ABV ABOVE D DRAIN FRT FIRE RESISTANT TREATED M METER PSF POUNDS PER SQUARE FOOT TB TACK BOARD

ACOUS ACOUSTICAL DBL DOUBLE FT FOOT MAS MASONRY PSI POUNDS PER SQUARE INCH TOC TOP OF CURB

ADJ ADJUSTABLE DEMO DEMOLISH, DEMOLITION FURR FURRING MAX MAXIMUM PT PRESSURE TREATED TOSC TOP OF STRUCTURAL CONCRETE

AFF ABOVE FINISH FLOOR DEPT DEPARTMENT FWC FABRIC WALL COVERING MDF MEDIUM DENSITY FIBER BOARD TEL TELEPHONE

ALUM ALUMINUM DF DRINKING FOUNTAIN MED MEDIUM QT QUARRY TILE THK THICK

ALT ALTERNATE DIA or Ø DIAMETER GA GAUGE MEMB MEMBRANE QTB QUARRY TILE BASE TOB TOP OF BEAM

ANOD ANODIZED DIM DIMENSION GALV GALVANIZED MTL METAL TOP TOP OF PAVEMENT

APPROX APPROXIMATELY DIV DIVISION GB GRAB BAR MFGR MANUFACTURER RI RISER TOM TOP OF MASONRY

AWP ACOUSTICAL WALL PANEL DL DEAD LOAD GC GENERAL CONTRACTOR MH MANHOLE R RADIUS TOS TOP OF STEEL (BOTTOM OF ROOF DECK)

DN DOWN GCLU GLAZED CMU MIN MINIMUM RB RUBBER BASE TP TOILET PARTITION

BD BOARD DS DOWN SPOUT GI GALVANIZED IRON MISC MISCELLANEOUS RCP REFLECTED CEILING PLAN TV TELEVISION

BLDG BUILDING DSP DRY STAND PIPE GL GLASS MM MILLIMETER RD ROOF DRAIN TYP TYPICAL

BOT BOTTOM DTL DETAIL GLB GLASS BLOCK MO MASONRY OPENING REF REFERENCE TZ TERRAZZO

BW BOTH WAYS DWG DRAWING GMT GLASS MOSAIC TILE MOD MODULAR REFR REFRIGERATOR TZB TERRAZZO BASE

BM BENCH MARK GMTW GLASS MOSAIC TILE WALL MTD MOUNT(ED) (ING) REINF REINFORCING

E EAST GR GRADE MUL MULLION REQ REQUIRE(D) (ING) UC UNDERCUT

C CHANNEL EA EACH GYP GYPSUM REV REVISION UNO UNLESS OTHERWISE NOTED

CC CUBICAL CURTAIN EF EPOXY FLOOR GYP BD GYPSUM BOARD N NORTH RH RIGHT HAND USC UNDER SEPARATE CONTRACT

CK CORK EFB EPOXY FLOOR BASE NAT NATURAL RM ROOM(S)

CAB CABINET EJ EXPANSION JOINT HC HOLLOW CORE NIC NOT IN CONTRACT ROW RIGHT OF WAY VAR VARNISH

CB CHALK BOARD EG END GUARD HDR HEADER NO or # NUMBER RVWC RIGID VINYL WALL COVERING VB VAPOR BARRIER

CFCI CONTRACTOR FURNISH CONTRACTOR INSTALL EL ELEVATION HDW HARDWARE NOM NOMINAL VB VINYL BASE

CFOI CONTRACTOR FURNISH OWNER INSTALL ET EPOXY TERRAZZO FLOOR HDWD HARDWOOD NRC NOISE REDUCTION COEFFICIENT S SOUTH VCT VINYL COMPOSITION TILE

CFT CUBIC FOOT ETB EPOXY TERRAZZO BASE HGT HEIGHT NTS NOT TO SCALE SB SPLASH BLOCK VERT VERTICAL

CG CORNER GUARD ELECT ELECTRICAL HM HOLLOW METAL SC SOLID CORE VEST VESTIBULE

CL, CENTER LINE EM ENTRANCE MAT HORIZ HORIZONTAL OC ON CENTER SCHED SCHEDULE VT VINYL TILE

CLG CEILING EMER EMERGENCY HP HIGH POINT OD OUTSIDE DIAMETER SECT SECTION VTR VENT THROUGH ROOF

CI CAST IRON ENCL ENCLOSURE HR HANDRAIL OFD OVERFLOW ROOF DRAIN SHR SHOWER VWC VINYL WALL COVERING

CLO CLOSET EP EPOXY PAINT HVAC HEATING VENTILATION AIR CONDITIONING OFF OFFICE SIM SIMILAR

CLR CLEAR EQ EQUAL OFOI OWNER FURNISH OWNER INSTALL SPECS SPECIFICATION(S) W WEST

CMP CROWN MOLDING PAINTED EQUIP EQUIPMENT ID INSIDE DIAMETER OFCI OWNER FURNISH CONTRACTOR INSTALL SPK SPEAKER W/ WITH

CMS CROWN MOLDING STAINED EWC ELECTRIC WATER COOLER INCL INCLUDING OVH OVERHEAD SQ SQUARE WBP WOOD BASE PAINTED

CMT CERAMIC MOSAIC TILE EXP EXPANSION INSUL INSULATION OH OPPOSITE HAND SS STAINLESS STEEL WBS WOOD BASE STAINED

CMTB CERAMIC MOSAIC TILE BASE EXIST EXISTING INT INTERIOR OPNG OPENING ST STONE WC WATER CLOSET

CMTW CERAMIC MOSAIC TILE WALL EXT EXTERIOR IPS IRON PIPE SIZE OPP OPPOSITE STC STONE COUNTERTOP WD WOOD

CMU CONCRETE MASONRY UNIT STW STONE WALL WDS WOOD STAINED

CO CASED OPENING FA FIRE ALARM J JOIST P PAINT(ED) STB STONE BASE WIN WINDOW

COL COLUMN FBO FURNISHED BY OTHERS JAN JANITOR PARA PARALLEL STC STAINED CONCRETE W/O WITHOUT

CONC CONCRETE FD FLOOR DRAIN JT JOINT PBD PARTICLE BOARD STD STANDARD WP WOOD PANELING PREFINISHED

CONST CONSTRUCTION

FE FIRE EXTINGUISHER PCF POUNDS PER CUBIC FOOT STL STEEL WPP WOOD PANELING PAINTED

CR

FEC FIRE EXTINGUISHER CABINET KIT KITCHEN PERF PERFORATED STO STORAGE WPS WOOD PANELING STAINED

CORR

CHAIR RAIL FFE FINISH FLOOR ELEVATION KO KNOCKOUT PERI PERIMETER STRUCT STRUCTURAL WS WATER STOP

CPT

CORRIDOR FHC FIRE HOSE CABINET PFL POUNDS PER LINEAR FOOT SV SHEET VINYL WSCT WAINSCOT

CPTB

CARPET FHVC FIRE HOSE VALVE CABINET L LENGTH/LONG PL PLATE SVB SHEET VINYL COVED BASE WT WEIGHT

CT

CARPET BASE FE FINISHED END LAB LABORATORY PLAM PLASTIC LAMINATE SYM SYMMETRICAL WWF WELDED WIRE FABRIC

CTB

CERAMIC TILE FLR FLOOR LAM LAMINATE PLAS PLASTER SYS SYSTEM

CTW

CERAMIC TILE BASE FOC FACE OF CONCRETE LH LEFT HAND PLYWD PLYWOOD

CERAMIC TILE WALL FOF FACE OF FINISH LI LINOLEUM PP PORCELAIN PAVER

CTSK COUNTERSINK FOM FACE OF MASONRY LIB LINOLEUM COVED BASE PPB PORCELAIN PAVER BASE

CYD CUBIC YARD FOS FACE OF STUDS LIT LINOLEUM TILE PPW PORCELAIN PAVER WALL

FPRF FIREPROOFING LL LIVE LOAD PR PAIR

CONT CONTINUOUS

NEW CONSTRUCTION

EXISTING CONSTRUCTION

DEMOLITION

HIDDEN LINE

FIRE/SMOKE BARRIERS

1 HOUR FIRE BARRIER

SMOKE/FIRE BARRIER

2 HOUR FIRE BARRIER

FIRE/SMOKE PARTITIONS

1 HOUR FIRE PARTITION

30 MIN. FIRE PARTITION

FIRE WALLS

2 HOURS

1FB

1SB

2FB

1FP

0.5FP

2FW

BRICK

CONCRETE

CONCRETE BLOCK

EARTH

INSULATION, BATT

INSULATION, RIGID

METAL

PLYWOOD

FINISH GRADE

HARDWOOD

WOOD FRAMING

THROUGH MEMBER

WOOD FRAMING

INTERRUPTED MEMBER

PARTITION TYPES

DOOR NUMBER

KEY NOTE (NEW)

KEY NOTE (DEMO)

EQUIPMENT / ACCESSORY

WINDOW TAG

COLUMN GRID

CEILING ELEVATION A.F.F.

REVISION

INTERIOR

ELEVATION

SECTION

NORTH

ROOM NAME

N

A###

NAME

ROOM NUMBER

REFER TO ROOM NUMBER

FOR TYPICAL INFORMATION

1t

SIM

MATCHLINE

EXTERIOR

ELEVATION

EXTERIOR WALL TYPES-

A.F.F.

0'-0"

ELEVATION HEIGHT

HR#-IP RAILING TAG

ALIGN

Revisions:

A u st in

S a n A n to n io

H o u s to n

B a rt o n

S p ri n g s

R o a d

S u it e

A u st in Te xa s

B ro a d w a y S u it e

S a n A n to n io

Te xa s

F a n n in

S tr e e t, S u it e

H o u st o n Te xa s p

.4

.7 f

.4

.7 p

.2

.6 f

.2

.6 p

.4

.1 f

.4

.1

A u to d e s k D o c s /A n g e lo S ta te

U n iv e rs it y /2

A

S U

P la z a V e rd e B ld g

-H

V A

C R p lm n t_

A R

C H

C e n tr a l.

rv t

/2

/2

:2

:2

A

M

P L

A Z

A V

E R

D E

B L

D G

H

V A

C R

E P

L A

C E

M E

N T

S

S V

A N

B U

R E N

S T, S A

N A

N G

E

LO

TX

A N

G E

LO

S

TA

TE

U

N

IV

E R

S

IT

Y

07/24/2026

Project No. 2574.02

CONTRACT DOCUMENTS

ARCHITECTURAL

ABBREVIATIONS AND

SYMBOLS

G1.1

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

GENERAL PROJECT

NOTES

TEXAS MAP VICINITY MAP LOCATION MAP

PLUMBING FIXTURES

ARCHITECTURAL ABBREVIATIONS

ARCHITECTURAL

LINETYPES

ARCHITECTURAL

MATERIALS

ARCHITECTURAL

SYMBOLS

Renovation Area 11,280 SF

Building Height 3 Stories, 36 Feet

Gross Square Footage Per Floor 11,220 SF

Total Gross Square Footage 33,660 SF

Building Construction Type IIB, Sprinklered

PROJECT SUMMARY

Existing Building Code 2021 International Existing Building Code

Accessibility Codes 2012 Texas Accessibilities Standards

City of San Angelo Accepted Amendments May 18, 2026

Energy Conservation Code 2021 International Energy Conservation Code

City of San Angelo Accepted Amendments May 18, 2026

Fuel Code 2021 Fuel Gas Code

City of San Angelo Accepted Amendments May 18, 2026

Fire Code 2021 International Fire Code

City of San Angelo Accepted Amendments May 18, 2026

Mechanical Code 2021 International Mechanical Code

City of San Angelo Accepted Amendments May 18, 2026

Plumbing Code 2021 International Plumbing Code

State: 2023 National Electrical Code

City of San Angelo Accepted Amendments May 18, 2026

Electrical Code City: 2020 National Electrical Code

City of San Angelo Accepted Amendments May 18, 2026

Building Code 2021 International Building Code

APPLICABLE CODES AND STANDARDS

JURISDICTION: City of San Angelo TX

LOCATION: 2010 S Van Buren St, San Angelo, TX 76904

PROJECT: Plaza Verde Building 3 HVAC Replacements

OR PROJECT NUMBER: 2574.02

OWNER: Angelo State University

BUILDING CODE ANALYSIS

TOM GREEN COUNTY

PROJECT

LOCATION

PROJECT

LOCATION

Roof Insulation above Deck=R-25 CI T C301.1

Climate Zone 3B T C301.1

2024 IECC ENERGY CODE ANALYSIS

Occupancy Types: Residential Group R-2 (Dormitory) 310.3

CHAPTER 3: USE & OCCUPANCY CLASSIFICATION

IBC

Secondary drains or scuppers Where roof drains are required, secondary (emergency overflow) roof drains or scuppers shall be provided where the roof perimeter extends above the roof in such a manner that water will be entrapped if the primary drains allow buildup for any reason.

1502.2

CHAPTER 15: ROOF ASSEMBLIES & ROOFTOP

STRUCTURES

Fire-resistance rating Shaft enclosures shall have a fire-resistance rating of not less than 2 hours where connecting four stories or more, and not less than 1 hour where connecting less than four stories. The number of stories connected by the shaft enclosure shall include any basements but not any mezzanines. Shaft enclosures shall have a fire-resistance not less than the floor assembly penetrated, but need not exceed 2 hours. Shaft enclosures shall...

713.4

Construction Shaft enclosures shall be constructed as fire barriers in accordance with Section 707 or horizontal assemblies in accordance with Section 711, or both.

713.2

CHAPTER 7: FIRE & SMOKE PROTECTION SYSTEMS

NO. DESCRIPTION DATE

UP

DN

UP

1. THE CONTRACTOR SHALL FURNISH ALL LABOR,

MATERIALS, TOOLS, EQUIPMENT AND RELATED ITEMS

REQUIRED TO COMPLETE THE DEMOLITION WORK AS

INDICATED BY THE CONTRACT DOCUMENTS

2. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE

WORK, USING THEIR BEST SKILL AND ATTENTION. THEY

SHALL BE SOLELY RESPONSIBLE FOR ALL DEMOLITION

MEANS, METHODS, TECHNIQUES, SEQUENCES AND

PROCEDURES. AND FOR COORDINATING ALL PORTIONS

OF THE WORK UNDER THE CONTRACT.

3. THE CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES

AND INSPECTIONS REQUIRED FOR THE EXECUTION OF

THE WORK

4. SERVICE CONNECTIONS SHALL BE SAFELY REMOVED,

CAPPED OR PLUGGED IN CONFORMITY WITH LOCAL

LAWS AND ORDINANCES, REQUIREMENTS OF LOCAL

UTILITY COMPANIES, AND THE NATIONAL BOARD OF

FIRE UNDERWRITERS, AND IN SUCH MANNER AS TO

NOT TO INTERFERE WITH USE OF THE OCCUPIED

SPACES IN THE BUILDING

5. REMOVE ALL MISCELLANEOUS DEVICES AS REQUIRED

TO INSTALL NEW FINISHES, INCLUDED BUT NOT LIMITED

TO PLUMBING FIXTURES, SIGNAGE, SWITCH PLATES,

TELEVISION BRACKETS, WALL OUTLET COVERS, ETC.

SAVE FOR REINSTALLATION AFTER COMPLETION OF

FINISH WORK AT EXISTING LOCATIONS.

6. CONTRACTOR TO COORDINATE WITH OWNER'S

REPRESENTATIVE FOR INFECTIOUS CONTROL

MEASURES DURING CONSTRUCTION

7. DASHED LINES INDICATE WALLS, DOORS, FIXTURES,

CASEWORK, ETC. TO BE REMOVED IN THEIR ENTIRETY,

U.N.O.

8. ANY QUESTIONS CONCERNING OWNERSHIP OF

SALVAGEABLE MATERIAL SHALL BE ANSWERED BY THE

OWNER, OR THE OWNER'S REPRESENTATIVE

9. INSTALL TEMPORARY DUST PARTITIONS WITH DOORS

FOR CONSTRUCTION ACCESS AROUND AREAS OF

WORK SO THAT OPERATIONS IN EXISTING ADJACENT

AREAS REMAIN DUST FREE. MAINTAIN IN PLACE UNTIL

COMPLETION OF CONSTRUCTION

10. IMMEDIATELY SEAL ALL PENETRATIONS IN EXISTING

SLAB OPEN DURING DEMOLITION WITH FIRESTOPPING

MATERIAL AND WATERPROOFING

11. SEAL ALL PENETRATIONS, NEW AND EXISTING, ABOVE

CEILING AT FIRE RATED AND SMOKE PARTITIONS IN

AREAS OF WORK AS REQUIRED TO MAINTAIN RATING

12. PATCH EXISTING PARTITIONS AFFECTED BY

DEMOLITION AND PREPARE FOR NEW FINISHES.

13. PREPARE FLOORS FOR NEW FINISHES AT DEMOLISHED

FLOOR FINISHES.

14. REFER TO FLOOR PLANS FOR EXACT

LOCATION/DIMENSIONS OF NEW OPENINGS ON

EXISTING WALLS.

N

TRUE NORTH

N

PLAN NORTH

GATHERING

GATHERING

GATHERING

2 BED UNIT

2 BED UNIT

2 BED UNIT

ACCESSIBLE

UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

TEAM ROOM

LAUNDRY

ACCESSIBLE

UNIT

2 BED UNIT

2 BED UNIT

RA UNIT

31102 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

CORRIDOR

CORRIDOR

CORRIDOR

275 275 275

2 BED UNIT

2 BED UNIT

3207 2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

RA UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

CORRIDOR

GATHERING

GATHERING

GATHERING

CORRIDOR

CORRIDOR

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

275 275 275

SHAFT SIDE ROOM SIDE

FLOOR FINISH

BASE

C-H STUD, TO MATCH

EXISTING SIZE AND

GAUGE

GYPSUM LINER

PANEL

CEILING AS

SCHEDULED

GYPSUM WALLBOARD -

ONE LAYER @ 1 HOUR

PARTITION

BOTTOM OF

STRUCTURE

Revisions:

A u st in

S a n A n to n io

H o u s to n

B a rt o n

S p ri n g s

R o a d

S u it e

A u st in Te xa s

B ro a d w a y S u it e

S a n A n to n io

Te xa s

F a n n in

S tr e e t, S u it e

H o u st o n Te xa s p

.4

.7 f

.4

.7 p

.2

.6 f

.2

.6 p

.4

.1 f

.4

.1

A u to d e s k D o c s /A n g e lo S ta te

U n iv e rs it y /2

A

S U

P la z a V e rd e B ld g

-H

V A

C R p lm n t_

A R

C H

C e n tr a l.

rv t

/2

/2

:2

:2

A

M

P L

A Z

A V

E R

D E

B L

D G

H

V A

C R

E P

L A

C E

M E

N T

S

S V

A N

B U

R E N

S T, S A

N A

N G

E

LO

TX

A N

G E

LO

S

TA

TE

U

N

IV

E R

S

IT

Y

07/24/2026

Project No. 2574.02

CONTRACT DOCUMENTS

DEMOLITION FLOOR

PLANS - LEVELS 1 & 2

A2.1

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

GENERAL

DEMOLITION NOTES

KEYNOTE LEGEND

270 REMOVE ENTIRE WIDTH OF SHAFT WALL FROM FLOOR

TO 7'-6" A.F.F. FOR MECHANICAL UPGRADES. AFTER

WORKS ARE FINALIZED, FILL IN OPENING WITH 1-HR

FIRE BARRIER PARTITION TO MATCH AND ALIGN WITH

EXISTING. SEE PARTITION DETAIL FOR REFERENCE.

275 REMOVE EXISTING CARPET FLOORING AND WALL

BASE IN ITS ENTIRETY

SCALE: 1/8" = 1'-0"

DEMOLITION FLOOR PLAN - LEVEL 1

SCALE: 1/8" = 1'-0"

DEMOLITION FLOOR PLAN - LEVEL 2

2 SCALE: 1/2" = 1'-0"

SHAFT WALL PARTITION

1. THE CONTRACTOR SHALL FURNISH ALL LABOR,

MATERIALS, TOOLS, EQUIPMENT AND RELATED ITEMS

REQUIRED TO COMPLETE THE DEMOLITION WORK AS

INDICATED BY THE CONTRACT DOCUMENTS

2. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE

WORK, USING THEIR BEST SKILL AND ATTENTION. THEY

SHALL BE SOLELY RESPONSIBLE FOR ALL DEMOLITION

MEANS, METHODS, TECHNIQUES, SEQUENCES AND

PROCEDURES. AND FOR COORDINATING ALL PORTIONS

OF THE WORK UNDER THE CONTRACT.

3. THE CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES

AND INSPECTIONS REQUIRED FOR THE EXECUTION OF

THE WORK

4. SERVICE CONNECTIONS SHALL BE SAFELY REMOVED,

CAPPED OR PLUGGED IN CONFORMITY WITH LOCAL

LAWS AND ORDINANCES, REQUIREMENTS OF LOCAL

UTILITY COMPANIES, AND THE NATIONAL BOARD OF

FIRE UNDERWRITERS, AND IN SUCH MANNER AS TO

NOT TO INTERFERE WITH USE OF THE OCCUPIED

SPACES IN THE BUILDING

5. REMOVE ALL MISCELLANEOUS DEVICES AS REQUIRED

TO INSTALL NEW FINISHES, INCLUDED BUT NOT LIMITED

TO PLUMBING FIXTURES, SIGNAGE, SWITCH PLATES,

TELEVISION BRACKETS, WALL OUTLET COVERS, ETC.

SAVE FOR REINSTALLATION AFTER COMPLETION OF

FINISH WORK AT EXISTING LOCATIONS.

6. CONTRACTOR TO COORDINATE WITH OWNER'S

REPRESENTATIVE FOR INFECTIOUS CONTROL

MEASURES DURING CONSTRUCTION

7. DASHED LINES INDICATE WALLS, DOORS, FIXTURES,

CASEWORK, ETC. TO BE REMOVED IN THEIR ENTIRETY,

U.N.O.

8. ANY QUESTIONS CONCERNING OWNERSHIP OF

SALVAGEABLE MATERIAL SHALL BE ANSWERED BY THE

OWNER, OR THE OWNER'S REPRESENTATIVE

9. INSTALL TEMPORARY DUST PARTITIONS WITH DOORS

FOR CONSTRUCTION ACCESS AROUND AREAS OF

WORK SO THAT OPERATIONS IN EXISTING ADJACENT

AREAS REMAIN DUST FREE. MAINTAIN IN PLACE UNTIL

COMPLETION OF CONSTRUCTION

10. IMMEDIATELY SEAL ALL PENETRATIONS IN EXISTING

SLAB OPEN DURING DEMOLITION WITH FIRESTOPPING

MATERIAL AND WATERPROOFING

11. SEAL ALL PENETRATIONS, NEW AND EXISTING, ABOVE

CEILING AT FIRE RATED AND SMOKE PARTITIONS IN

AREAS OF WORK AS REQUIRED TO MAINTAIN RATING

12. PATCH EXISTING PARTITIONS AFFECTED BY

DEMOLITION AND PREPARE FOR NEW FINISHES.

13. PREPARE FLOORS FOR NEW FINISHES AT DEMOLISHED

FLOOR FINISHES.

14. REFER TO FLOOR PLANS FOR EXACT

LOCATION/DIMENSIONS OF NEW OPENINGS ON

EXISTING WALLS.

N

TRUE NORTH

N

PLAN NORTH

272NOT IN SCOPE

277 277

277277

277 277

274 274

274 274

2 BED UNIT

2 BED UNIT

3307 2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

GATHERING

GATHERING

GATHERING

CORRIDOR

2 BED UNIT

2 BED UNIT

RA UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

CORRIDOR

CORRIDOR

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

275 275 275

SCALE: 1/8" = 1'-0"

DEMOLITION ROOF PLAN

Revisions:

A u st in

S a n A n to n io

H o u s to n

B a rt o n

S p ri n g s

R o a d

S u it e

A u st in Te xa s

B ro a d w a y S u it e

S a n A n to n io

Te xa s

F a n n in

S tr e e t, S u it e

H o u st o n Te xa s p

.4

.7 f

.4

.7 p

.2

.6 f

.2

.6 p

.4

.1 f

.4

.1

A u to d e s k D o c s /A n g e lo S ta te

U n iv e rs it y /2

A

S U

P la z a V e rd e B ld g

-H

V A

C R p lm n t_

A R

C H

C e n tr a l.

rv t

/2

/2

:2

:2

A

M

P L

A Z

A V

E R

D E

B L

D G

H

V A

C R

E P

L A

C E

M E

N T

S

S V

A N

B U

R E N

S T, S A

N A

N G

E

LO

TX

A N

G E

LO

S

TA

TE

U

N

IV

E R

S

IT

Y

07/24/2026

Project No. 2574.02

CONTRACT DOCUMENTS

DEMOLITION FLOOR

PLANS - LEVEL 3 & ROOF

A2.2

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

GENERAL

DEMOLITION NOTES

KEYNOTE LEGEND

270 REMOVE ENTIRE WIDTH OF SHAFT WALL FROM FLOOR

TO 7'-6" A.F.F. FOR MECHANICAL UPGRADES. AFTER

WORKS ARE FINALIZED, FILL IN OPENING WITH 1-HR

FIRE BARRIER PARTITION TO MATCH AND ALIGN WITH

EXISTING. SEE PARTITION DETAIL FOR REFERENCE.

272 REMOVE AND DEMOLISH EXISTING ROOFING SYSTEM

INCLUDING MEMBRANE, INSULATION AND ROOFING

CURBS DOWN TO EXISTING DECK

273 REMOVE AND DEMOLISH EXISTING METAL PARAPET

COPING IN ITS ENTIRETY

274 PATCH AND SEAL EXISTING ROOF OPENINGS SERVING

EXISTING REFRIGERANT PIPE RISERS THROUGH

ROOF, REF. STRUCTURAL

275 REMOVE EXISTING CARPET FLOORING AND WALL

BASE IN ITS ENTIRETY

276 ALL EXISTING VENTS THROUGH ROOF TO REMAIN

277 DEMOLISH OPENING IN EXISTING PARAPET FOR 8" H X

12" W SECONDARY OVERFLOW SCUPPER, REF. 4/A6.2

279 EXISTING ELEVATOR SHAFT TO REMAIN. REMOVE AND

DEMOLISH EXISTING ROOFING SYSTEM ABOVE

EXISTING DECK

280 EXISTING MECHANICAL EQUIPMENT TO BE

DEMOLISHED, TYP. REF. MECHANICAL

649 EXISTING ROOF CRICKET

650 EXISTING ROOF HATCH TO REMAIN

651 EXISTING ROOF PENETRATION FOR CONDENSATE

PIPE RISER TO REMAIN

652 EXISTING WATER HEATER FLUES TO REMAIN

SCALE: 1/8" = 1'-0"

DEMOLITION FLOOR PLAN - LEVEL 3

MATERIALS, TOOLS, EQUIPMENT AND RELATED ITEMS

REQUIRED TO COMPLETE THE DEMOLITION WORK AS

INDICATED BY THE CONTRACT DOCUMENTS

2. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE

WORK, USING THEIR BEST SKILL AND ATTENTION. THEY

SHALL BE SOLELY RESPONSIBLE FOR ALL DEMOLITION

MEANS, METHODS, TECHNIQUES, SEQUENCES AND

PROCEDURES. AND FOR COORDINATING ALL PORTIONS

OF THE WORK UNDER THE CONTRACT.

3. THE CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES

AND INSPECTIONS REQUIRED FOR THE EXECUTION OF

THE WORK

4. SERVICE CONNECTIONS SHALL BE SAFELY REMOVED,

CAPPED OR PLUGGED IN CONFORMITY WITH LOCAL

LAWS AND ORDINANCES, REQUIREMENTS OF LOCAL

UTILITY COMPANIES, AND THE NATIONAL BOARD OF

FIRE UNDERWRITERS, AND IN SUCH MANNER AS TO

NOT TO INTERFERE WITH USE OF THE OCCUPIED

SPACES IN THE BUILDING

5. REMOVE ALL MISCELLANEOUS DEVICES AS REQUIRED

TO INSTALL NEW FINISHES, INCLUDED BUT NOT LIMITED

TO PLUMBING FIXTURES, SIGNAGE, SWITCH PLATES,

TELEVISION BRACKETS, WALL OUTLET COVERS, ETC.

SAVE FOR REINSTALLATION AFTER COMPLETION OF

FINISH WORK AT EXISTING LOCATIONS.

6. CONTRACTOR TO COORDINATE WITH OWNER'S

REPRESENTATIVE FOR INFECTIOUS CONTROL

MEASURES DURING CONSTRUCTION

7. DASHED LINES INDICATE WALLS, DOORS, FIXTURES,

CASEWORK, ETC. TO BE REMOVED IN THEIR ENTIRETY,

U.N.O.

8. ANY QUESTIONS CONCERNING OWNERSHIP OF

SALVAGEABLE MATERIAL SHALL BE ANSWERED BY THE

OWNER, OR THE OWNER'S REPRESENTATIVE

9. INSTALL TEMPORARY DUST PARTITIONS WITH DOORS

FOR CONSTRUCTION ACCESS AROUND AREAS OF

WORK SO THAT OPERATIONS IN EXISTING ADJACENT

AREAS REMAIN DUST FREE. MAINTAIN IN PLACE UNTIL

COMPLETION OF CONSTRUCTION

10. IMMEDIATELY SEAL ALL PENETRATIONS IN EXISTING

SLAB OPEN DURING DEMOLITION WITH FIRESTOPPING

MATERIAL AND WATERPROOFING

11. SEAL ALL PENETRATIONS, NEW AND EXISTING, ABOVE

CEILING AT FIRE RATED AND SMOKE PARTITIONS IN

AREAS OF WORK AS REQUIRED TO MAINTAIN RATING

12. PATCH EXISTING PARTITIONS AFFECTED BY

DEMOLITION AND PREPARE FOR NEW FINISHES.

13. PREPARE FLOORS FOR NEW FINISHES AT DEMOLISHED

FLOOR FINISHES.

14. REFER TO FLOOR PLANS FOR EXACT

LOCATION/DIMENSIONS OF NEW OPENINGS ON

EXISTING WALLS.

N

TRUE NORTH

N

PLAN NORTH

271 271 271

271 271

271271

271 271

271 271

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

RA UNIT

2 BED UNIT

3112 2 BED UNIT

ACCESSIBLE

UNIT

2 BED UNIT

ACCESSIBLE

UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

LAUNDRY

TEAM ROOM

271271

271 271

271271

271 271

271 271

271 271

271 271

271 271

271 271

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

RA UNIT

2 BED UNIT

3212 2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

32132 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

A

.1

Revisions:

A u st in

S a n A n to n io

H o u s to n

B a rt o n

S p ri n g s

R o a d

S u it e

A u st in Te xa s

B ro a d w a y S u it e

S a n A n to n io

Te xa s

F a n n in

S tr e e t, S u it e

H o u st o n Te xa s p

.4

.7 f

.4

.7 p

.2

.6 f

.2

.6 p

.4

.1 f

.4

.1

A u to d e s k D o c s /A n g e lo S ta te

U n iv e rs it y /2

A

S U

P la z a V e rd e B ld g

-H

V A

C R p lm n t_

A R

C H

C e n tr a l.

rv t

/2

/2

:2

:2

A

M

P L

A Z

A V

E R

D E

B L

D G

H

V A

C R

E P

L A

C E

M E

N T

S

S V

A N

B U

R E N

S T, S A

N A

N G

E

LO

TX

A N

G E

LO

S

TA

TE

U

N

IV

E R

S

IT

Y

07/24/2026

Project No. 2574.02

CONTRACT DOCUMENTS

DEMOLITION REFLECTED

CEILING PLANS - LEVELS

1 & 2

A2.3

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

GENERAL

DEMOLITION NOTES

KEYNOTE LEGEND

271 REMOVE AND DEMOLISH EXISTING GYP BOARD

CEILING IN ITS ENTIRETY

278 REMOVE, SALVAGE AND REINSTALL CEILING AS

NEEDED FOR MECHANICAL SCOPE

SCALE: 1/8" = 1'-0"

DEMOLITION REFLECTED CEILING PLAN - LEVEL 1

SCALE: 1/8" = 1'-0"

DEMOLITION REFLECTED CEILING PLAN - LEVEL 2

MATERIALS, TOOLS, EQUIPMENT AND RELATED ITEMS

REQUIRED TO COMPLETE THE DEMOLITION WORK AS

INDICATED BY THE CONTRACT DOCUMENTS

2. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE

WORK, USING THEIR BEST SKILL AND ATTENTION. THEY

SHALL BE SOLELY RESPONSIBLE FOR ALL DEMOLITION

MEANS, METHODS, TECHNIQUES, SEQUENCES AND

PROCEDURES. AND FOR COORDINATING ALL PORTIONS

OF THE WORK UNDER THE CONTRACT.

3. THE CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES

AND INSPECTIONS REQUIRED FOR THE EXECUTION OF

THE WORK

4. SERVICE CONNECTIONS SHALL BE SAFELY REMOVED,

CAPPED OR PLUGGED IN CONFORMITY WITH LOCAL

LAWS AND ORDINANCES, REQUIREMENTS OF LOCAL

UTILITY COMPANIES, AND THE NATIONAL BOARD OF

FIRE UNDERWRITERS, AND IN SUCH MANNER AS TO

NOT TO INTERFERE WITH USE OF THE OCCUPIED

SPACES IN THE BUILDING

5. REMOVE ALL MISCELLANEOUS DEVICES AS REQUIRED

TO INSTALL NEW FINISHES, INCLUDED BUT NOT LIMITED

TO PLUMBING FIXTURES, SIGNAGE, SWITCH PLATES,

TELEVISION BRACKETS, WALL OUTLET COVERS, ETC.

SAVE FOR REINSTALLATION AFTER COMPLETION OF

FINISH WORK AT EXISTING LOCATIONS.

6. CONTRACTOR TO COORDINATE WITH OWNER'S

REPRESENTATIVE FOR INFECTIOUS CONTROL

MEASURES DURING CONSTRUCTION

7. DASHED LINES INDICATE WALLS, DOORS, FIXTURES,

CASEWORK, ETC. TO BE REMOVED IN THEIR ENTIRETY,

U.N.O.

8. ANY QUESTIONS CONCERNING OWNERSHIP OF

SALVAGEABLE MATERIAL SHALL BE ANSWERED BY THE

OWNER, OR THE OWNER'S REPRESENTATIVE

9. INSTALL TEMPORARY DUST PARTITIONS WITH DOORS

FOR CONSTRUCTION ACCESS AROUND AREAS OF

WORK SO THAT OPERATIONS IN EXISTING ADJACENT

AREAS REMAIN DUST FREE. MAINTAIN IN PLACE UNTIL

COMPLETION OF CONSTRUCTION

10. IMMEDIATELY SEAL ALL PENETRATIONS IN EXISTING

SLAB OPEN DURING DEMOLITION WITH FIRESTOPPING

MATERIAL AND WATERPROOFING

11. SEAL ALL PENETRATIONS, NEW AND EXISTING, ABOVE

CEILING AT FIRE RATED AND SMOKE PARTITIONS IN

AREAS OF WORK AS REQUIRED TO MAINTAIN RATING

12. PATCH EXISTING PARTITIONS AFFECTED BY

DEMOLITION AND PREPARE FOR NEW FINISHES.

13. PREPARE FLOORS FOR NEW FINISHES AT DEMOLISHED

FLOOR FINISHES.

14. REFER TO FLOOR PLANS FOR EXACT

LOCATION/DIMENSIONS OF NEW OPENINGS ON

EXISTING WALLS.

N

TRUE NORTH

N

PLAN NORTH

271 271

271271

271 271

271271

271 271

271271

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

RA UNIT

2 BED UNIT

3312 2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

Revisions:

A u st in

S a n A n to n io

H o u s to n

B a rt o n

S p ri n g s

R o a d

S u it e

A u st in Te xa s

B ro a d w a y S u it e

S a n A n to n io

Te xa s

F a n n in

S tr e e t, S u it e

H o u st o n Te xa s p

.4

.7 f

.4

.7 p

.2

.6 f

.2

.6 p

.4

.1 f

.4

.1

A u to d e s k D o c s /A n g e lo S ta te

U n iv e rs it y /2

A

S U

P la z a V e rd e B ld g

-H

V A

C R p lm n t_

A R

C H

C e n tr a l.

rv t

/2

/2

:2

:3

A

M

P L

A Z

A V

E R

D E

B L

D G

H

V A

C R

E P

L A

C E

M E

N T

S

S V

A N

B U

R E N

S T, S A

N A

N G

E

LO

TX

A N

G E

LO

S

TA

TE

U

N

IV

E R

S

IT

Y

07/24/2026

Project No. 2574.02

CONTRACT DOCUMENTS

DEMOLITION REFLECTED

CEILING PLAN - LEVEL 3

A2.4

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

GENERAL

DEMOLITION NOTES

KEYNOTE LEGEND

271 REMOVE AND DEMOLISH EXISTING GYP BOARD

CEILING IN ITS ENTIRETY

278 REMOVE, SALVAGE AND REINSTALL CEILING AS

NEEDED FOR MECHANICAL SCOPE

SCALE: 1/8" = 1'-0"

DEMOLITION REFLECTED CEILING PLAN - LEVEL 3

1. REFER TO SHEET A6.X FOR TYPICAL ROOF

DETAILS

2. NOT ALL ROOF PENETRATIONS ARE SHOWN

ON THE ARCHITECTURAL ROOF PLANS.

3. ALL ROOFING AREAS ARE MODIFIED

BITUMINOUS UNLESS NOTED OTHERWISE.

4. MINIMUM SLOPE FOR ROOF IS 1/4" PER 1'-0"

UNLESS NOTED OTHERWISE.

5. ALL SADDLES OR CRICKETS ARE FORMED

WITH TAPERED INSULATION UNLESS NOTED

OTHERWISE.

GENERAL ROOF NOTES

N

TRUE NORTH

N

PLAN NORTH

A.1 A.2 A.3 A.4 A.5 A.6 A.7 A.8 A.9

A.A

A.B

A.C

A.D

A.E

A.F

A.G

A.11A.10

/4

/4

/4

/4

/4

/4

/4

/4

" 630

RIDGE LINE

NOT IN SCOPE

617617

A6.2

A6.2

A6.2

A6.2

A6.2

A6.2

A6.2

A6.2

A6.2

__________3

A6.2

A6.2

A6.2

A6.2

TYP

/4

Revisions:

A u st in

S a n A n to n io

H o u s to n

B a rt o n

S p ri n g s

R o a d

S u it e

A u st in Te xa s

B ro a d w a y S u it e

S a n A n to n io

Te xa s

F a n n in

S tr e e t, S u it e

H o u st o n Te xa s p

.4

.7 f

.4

.7 p

.2

.6 f

.2

.6 p

.4

.1 f

.4

.1

A u to d e s k D o c s /A n g e lo S ta te

U n iv e rs it y /2

A

S U

P la z a V e rd e B ld g

-H

V A

C R p lm n t_

A R

C H

C e n tr a l.

rv t

/2

/2

:2

:3

A

M

P L

A Z

A V

E R

D E

B L

D G

H

V A

C R

E P

L A

C E

M E

N T

S

S V

A N

B U

R E N

S T, S A

N A

N G

E

LO

TX

A N

G E

LO

S

TA

TE

U

N

IV

E R

S

IT

Y

07/24/2026

Project No. 2574.02

CONTRACT DOCUMENTS

ROOF PLAN

A3.5

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

KEYNOTE LEGEND

616 LOCATION OF NEW OVERFLOW SCUPPER

617 PREFINISHED METAL COPING, SLOPED TO DRAIN

630 ROOF CRICKET

650 EXISTING ROOF HATCH TO REMAIN

655 MECHANICAL EQUIPMENT, TYP. REF. MECHANICAL

SCALE: 1/8" = 1'-0"

ROOF PLAN

5/8" COVER BOARD

STEEL ROOF DECK

SEPARATION SHEET. SINGLE PLY

ROOF MEMBRANE

P.T. WOOD NAILERS - 7 1/4" WIDE BY

DEPTH OF INSULATION. SECURE TO

DECK @ 12" O.C. STAGGERED

CAP SHEET

EQUIPMENT CURB

24 GA GALV CAP

SECURED W/ NEOPRENE

HEAD SCREWS @ 24" O.C.

4" 2"

FASTENERS AT 8" O.C.

NAIL WITH WASHER HEAD

TO SECURE MEMBRANE3

R13 BATT INSULATION, MIN. 4" HIGH

3 1/2"

ROOF INSULATION

P.T. PLYWOOD

SINGLE PLY ROOF MEMBRANE

BASE FLASHING

CUT-EDGE SEALANT

BONDING ADHESIVE

5/8" COVER BOARD

ROOF INSULATION

SINGLE-PLY ROOFING MEMBRANE

TOS

VARIES

EXISTING STEEL ROOF DECK

/8

S P

E C

IF

IE

D

A S

PLUMBING VENT STACK

5/8" COVER BOARD

ROOF INSULATION

STEEL ROOF DECKNOTE:

1. VENT STACKS AND OTHER PIPES SHALL

HAVE A MINIMUM OF 12 INCHES OF

CLEARANCE ON ALL SIDES FROM WALLS,

CURBS AND OTHER PROJECTIONS TO

FACILITATE PROPER FLASHING.

SINGLE PLY ROOF

MEMBRANE

PIPE SHALL BE BRACED BACK TO

THE STRUCTURAL FRAME

DIRECTLY BELOW THE ROOF DECK

THERMOPLASTIC PRE-MOLDED

PIPE FLASHING

STAINLESS STEEL

CLAMPING RING

SINGLE PLY ROOF MEMBRANE

ROOF INSULATION

STEEL ROOF DECK

SEPARATION SHEET. SINGLE PLY ROOF MEMBRANE

P.T. WOOD NAILERS - 5 1/2" WIDE BY

DEPTH OF INSULATION. SECURE TO

DECK @ 12" O.C. STAGGERED

1/2" P.T. PLYWOOD

SINGLE PLY ROOF MEMBRANE BASE FLASHING

EXHAUST FAN OR VENT

NEOPRENE HEAD SCREWS

@ 16" O.C., MIN 2 EACH SIDE

PREFAB METAL CURB. THYCURB TC-3, OR APPROVED

EQUAL (18 GA GALV. STEEL SHELL AND BASE PLATE, 1

1/2" 3LB DENSITY INSULATION & FACTORY INSTALLED

2X2 NAILER) ANCHOR TO WOOD NAILERS @ 6" O.C.

M

IN

FASTENERS @ 8" O.C. TO

SECURE MEMBRANE

NOTES:

1. ON UPSLOPE OF UNIT,

PROVIDE TAPERED CRICKET

1/2" COVER BOARD

CUT-EDGE SEALANT

BONDING ADHESIVE

1"

MIN 4"

SINGLE PLY ROOF

MEMBRANE BASE

FLASHING

4" MIN. FLANGE - PRIME, SET

IN MASTIC AND FASTEN.

RADIUS CORNERS OF

FLANGE

SINGLE PLY ROOF

MEMBRANE

5/8" COVER BOARD

P.T. WOOD NAILERS 5 1/2" WIDE

BY DEPTH OF INSULATION

SEPARATION SHEET.

SINGLE PLY ROOF

MEMBRANE

METAL ROOF DECK

FILL VOID WITH

COMPRESSIBLE INSULATION

1/4" ANNULAR SPACE

AROUND PENETRATION

SEALANT

STAINLESS STEEL DRAWBAND

24 GA. GALV. SHEET METAL

RAIN COLLAR, SOLDER ALL

JOINTS

24 GA. GALV. SHEET METAL

PITCH PAN, SOLDER/WELD

NON-SHRINK GROUT

1/ 4"

PIPE/CONDUIT

POURABLE SEALANT

THERMOPLASTIC PRE-

FABRICATED SEALANT POCKET

ROOF INSULATION (DEPTH AS SPECIFIED)

EXISTING STEEL ROOF DECK

EXISTING P.T. WOOD NAILERS

EXISTING CURB COUNTER FLASHING

NOTES:

1. ON UPSLOPE OF UNIT, PROVIDE TAPERED CRICKET

EXISTING RIGID

INSULATION

EXISTING CONT.

STEEL ANGLE

SINGLE PLY ROOF MEMBRANE

CONT. FIBER CANT

COVER BOARD

CUT-EDGE SEALANT

1/2" P.T. PLYWOOD

Revisions:

A u st in

S a n A n to n io

H o u s to n

B a rt o n

S p ri n g s

R o a d

S u it e

A u st in Te xa s

B ro a d w a y S u it e

S a n A n to n io

Te xa s

F a n n in

S tr e e t, S u it e

H o u st o n Te xa s p

.4

.7 f

.4

.7 p

.2

.6 f

.2

.6 p

.4

.1 f

.4

.1

A u to d e s k D o c s /A n g e lo S ta te

U n iv e rs it y /2

A

S U

P la z a V e rd e B ld g

-H

V A

C R p lm n t_

A R

C H

C e n tr a l.

rv t

/2

/2

:2

:3

A

M

P L

A Z

A V

E R

D E

B L

D G

H

V A

C R

E P

L A

C E

M E

N T

S

S V

A N

B U

R E N

S T, S A

N A

N G

E

LO

TX

A N

G E

LO

S

TA

TE

U

N

IV

E R

S

IT

Y

07/24/2026

Project No. 2574.02

CONTRACT DOCUMENTS

EXTERIOR DETAILS

A6.1

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

SCALE: 3" = 1'-0"

EQUIPMENT CURB DETAIL

2 SCALE: 3" = 1'-0"

EXHAUST FAN CURB DETAIL

SCALE: 3" = 1'-0"

PIPE/CONDUIT PENETRATION POCKET

4 SCALE: 3" = 1'-0"

VENT THRU ROOF (VTR)

SCALE: 3" = 1'-0"

R1 SINGLE PLY ROOF ASSEMBLY

SCALE: 3" = 1'-0"

ROOF HATCH DETAIL

EXISTING PRE-FORMED CORNICE TRIM

EXISTING EIFS ACRYLIC COATING SYSTEM

EXISTING PLYWOOD SHEATHING

SINGLE PLY ROOFING MEMBRANE

EXISTING INSULATED CONCRETE

WALL SYSTEM

1/2" COVER BOARD

CONT. P.T. 1/2" VENEER

CORE PLYWOOD

ROOF NAILING

CONT. P.T. 2x8 TAPERED

WOOD NAILER

CONT. CLEAT

/2

CONT. CLEAT

CONT. METAL COPING W/1"

STANDING SEAM JOINTS

EXISTING CORNICE

BACKER ROD AND

FLEXIBLE SEALANT AS

REQUIRED AT LOCATIONS

PRESENTING A GAP

LARGER THAN 1/4"

BETWEEN EXISTING WALL

AND NEW COPING

EXISTING PRE-FORMED CORNICE TRIM

EXISTING EIFS ACRYLIC COATING SYSTEM

EXISTING PLYWOOD SHEATHING

SINGLE PLY ROOFING MEMBRANE

CONT. P.T. 1/2" VENEER

CORE PLYWOOD

EXISTING INSULATED CONCRETE

WALL SYSTEM

5/8" COVERBOARD

EXISTING ACRYLIC COATING

ROOF NAILING

EXISTING CORNICE

CONT. P.T. 2x6 TAPERED

WOOD NAILER

CONT. CLEAT

/2

CONT. CLEAT

CONT. METAL COPING W/1"

STANDING SEAM JOINTS

BACKER ROD AND

FLEXIBLE SEALANT AS

REQUIRED AT LOCATIONS

PRESENTING A GAP

LARGER THAN 1/4"

BETWEEN EXISTING WALL

AND NEW COPING

SINGLE-PLY ROOFING MEMBRANE

EXISTING INSULATED CONCRETE

WALL SYSTEM

5/8" COVER BOARD

ROOF INSULATION (DEPTH AS SPECIFIED)

5/8" COVER BOARD

SINGLE-PLY ROOFING MEMBRANE

EXISTING STEEL ROOF DECK

EXISTING STRUCTURAL JOIST

E X

IS

T

IN

G

O P

E N

IN

G

EXISTING STEEL LINTEL (ONLY AT BRICK)

EXISTING THROUGH-WALL FLASHING

STAINLESS STEEL SCUPPER LINER

5/8" ROOF COVERBOARD

2X P.T. NAILERS

EXISTING METAL ROOF DECK

EXISTING STRUCTURAL JOIST

SINGLE-PLY ROOFING MEMBRANE

SEALANT

SINGLE-PLY ROOFING MEMBRANE

SEAL EDGES OF MEMBRANE

TO SCUPPER LINER

CONT. SEPARATION MEMBRANE

O P

E N

IN

G

STEEL LINTEL (ONLY AT BRICK)

PRE-FINISHED METAL COVER

STAINLESS STEEL SCUPPER LINER

5/8" ROOF COVERBOARD

P.T. WOOD BLOCKING TO ALIGN WITH

CANT. 2" ABOVE SCUPPER OUTLET

EXISTING METAL ROOF DECK

EXISTING STRUCTURAL JOIST

SINGLE-PLY ROOFING MEMBRANE

SEALANT

SINGLE-PLY ROOFING MEMBRANE

SEAL EDGES OF MEMBRANE

TO SCUPPER LINER

CONT. SEPARATION MEMBRANE

CONT. SEALANT

CONT. SEALANT

PRE-FINISHED METAL COVER

SCALE: 3" = 1'-0"

ROOF CORNICE AT BRICK

SCALE: 3" = 1'-0"

ROOF CORNICE AT ACRYLIC COATING

SCALE: 3" = 1'-0"

ROOF PARAPET BASE

Revisions:

A u st in

S a n A n to n io

H o u s to n

B a rt o n

S p ri n g s

R o a d

S u it e

A u st in Te xa s

B ro a d w a y S u it e

S a n A n to n io

Te xa s

F a n n in

S tr e e t, S u it e

H o u st o n Te xa s p

.4

.7 f

.4

.7 p

.2

.6 f

.2

.6 p

.4

.1 f

.4

.1

A u to d e s k D o c s /A n g e lo S ta te

U n iv e rs it y /2

A

S U

P la z a V e rd e B ld g

-H

V A

C R p lm n t_

A R

C H

C e n tr a l.

rv t

/2

/2

:2

:3

A

M

P L

A Z

A V

E R

D E

B L

D G

H

V A

C R

E P

L A

C E

M E

N T

S

S V

A N

B U

R E N

S T, S A

N A

N G

E

LO

TX

A N

G E

LO

S

TA

TE

U

N

IV

E R

S

IT

Y

07/24/2026

Project No. 2574.02

CONTRACT DOCUMENTS

EXTERIOR DETAILS

A6.2

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

SCALE: 3" = 1'-0"

ROOF SCUPPER

SCALE: 3" = 1'-0"

OVERFLOW SCUPPER

N

TRUE NORTH

N

PLAN NORTH

EXISTING ACT CEILING

PAINTED GYPSUM WALL BOARD

OUT OF SCOPE

EXISTING PAINTED GYPSUM WALL BOARD

1. ALIGN NEW CEILINGS TO MATCH EXISTING HEIGHT.

CONTRACTOR TO VERIFY HEIGHT IN FIELD.

2. PAINT DESIGNATIONS AT GYP CEILINGS AND FURR

DOWNS APPLY TO ALL EXPOSED GYP U.N.O. GYP

CEILINGS AND FURR DOWNS TO BE PT2 U.N.O.

3. NOT ALL CEILING DEVICES ARE SHOWN ON THE

ARCHITECTURAL REFLECTED CEILING PLAN.

4. ROOMS OPEN TO STRUCTURE (WITH EXCEPTION

OF MEP ROOMS, UTILITY ROOMS, UTILITY CLOSETS,

AND STORAGE AREAS) PAINT -PT2 - ALL EXPOSED

STRUCTURE, DUCTWORK, CONDUITS, AND MEP

PIPING UNLESS NOTED OTHERWISE.

CORRIDOR

CORRIDOR

CORRIDOR

GATHERING

GATHERING

GATHERING

2 BED UNIT

2 BED UNIT

3107 2 BED UNIT

2 BED UNIT

2 BED UNIT

ACCESSIBLE

UNIT

2 BED UNIT

ACCESSIBLE

UNIT

2 BED UNIT

2 BED UNIT

RA UNIT

31102 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

TEAM ROOM

3118 LAUNDRY

RR

RR

38 RR

RR

RR

41 RR

RR

RR

RR

RR

RR

47RR

RR

RR

RR

RR

RR

VANITY

VANITY

55 VANITY

VANITY

VANITY

58 VANITY

VANITY

VANITY

61VANITY

VANITY

65VANITY

VANITY

VANITY

VANITY

VANITY

VANITY

JAN/ELEC

MECH

ELEC

ELEC

STAIRS

ELEV. MACH.

RM.

3120A

SPRINKLER RM

3120C

800 800

A

.1

A

.1

A

.1

TYP

2'-3"

T Y

P

DRYER PLENUM

3120B

EXISTING CROWN MOLDING

EXISTING

GYP BOARD

BOTTOM OF FURRDOWN

SCHEDULED SURFACE

MOUNTED LIGHT FIXTURE

Revisions:

A u st in

S a n A n to n io

H o u s to n

B a rt o n

S p ri n g s

R o a d

S u it e

A u st in Te xa s

B ro a d w a y S u it e

S a n A n to n io

Te xa s

F a n n in

S tr e e t, S u it e

H o u st o n Te xa s p

.4

.7 f

.4

.7 p

.2

.6 f

.2

.6 p

.4

.1 f

.4

.1

A u to d e s k D o c s /A n g e lo S ta te

U n iv e rs it y /2

A

S U

P la z a V e rd e B ld g

-H

V A

C R p lm n t_

A R

C H

C e n tr a l.

rv t

/2

/2

:2

:3

A

M

P L

A Z

A V

E R

D E

B L

D G

H

V A

C R

E P

L A

C E

M E

N T

S

S V

A N

B U

R E N

S T, S A

N A

N G

E

LO

TX

A N

G E

LO

S

TA

TE

U

N

IV

E R

S

IT

Y

07/24/2026

Project No. 2574.02

CONTRACT DOCUMENTS

REFLECTED CEILING

PLAN

A9.1

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

RCP LEGEND

GENERAL RCP NOTES

SCALE: 1/8" = 1'-0"

REFLECTED CEILING PLAN - LEVEL 1

KEYNOTE LEGEND

800 REFINISH EXISTING CROWN MOLDING IN PT4.

SCALE: 3" = 1'-0"

LIGHT COVE DETAIL

N

TRUE NORTH

N

PLAN NORTH

EXISTING ACT CEILING

PAINTED GYPSUM WALL BOARD

OUT OF SCOPE

EXISTING PAINTED GYPSUM WALL BOARD

1. ALIGN NEW CEILINGS TO MATCH EXISTING HEIGHT.

CONTRACTOR TO VERIFY HEIGHT IN FIELD.

2. PAINT DESIGNATIONS AT GYP CEILINGS AND FURR

DOWNS APPLY TO ALL EXPOSED GYP U.N.O. GYP

CEILINGS AND FURR DOWNS TO BE PT2 U.N.O.

3. NOT ALL CEILING DEVICES ARE SHOWN ON THE

ARCHITECTURAL REFLECTED CEILING PLAN.

4. ROOMS OPEN TO STRUCTURE (WITH EXCEPTION

OF MEP ROOMS, UTILITY ROOMS, UTILITY CLOSETS,

AND STORAGE AREAS) PAINT -PT2 - ALL EXPOSED

STRUCTURE, DUCTWORK, CONDUITS, AND MEP

PIPING UNLESS NOTED OTHERWISE.

2 BED UNIT

2 BED UNIT

VANITY

VANITY

2 BED UNIT

2 BED UNIT

VANITY

VANITY

2 BED UNIT

2 BED UNIT

VANITY

VANITY

2 BED UNIT

2 BED UNIT

VANITY

VANITY

2 BED UNIT

VANITY

RR

2 BED UNIT

2 BED UNIT

VANITY

RR

RR

VANITY

VANITY

2 BED UNIT

2 BED UNIT

VANITY

VANITY

2 BED UNIT

RA UNIT

VANITY

2 BED UNIT

2 BED UNIT

VANITY

2 BED UNIT

2 BED UNIT

VANITY

VANITY

CORRIDOR

CORRIDOR

CORRIDOR

GATHERING

GATHERING

GATHERING

STAIRS

ELEC

IDF

JAN/ELEC

MECH

RR

RR

82 RR

RR

RR

RR

RR

RR

RR

115RR

RR

RR

RR

RR

RR

RR

A

.1

800 800

A

.1

A

.1

2 BED UNIT

2 BED UNIT

VANITY

VANITY

VANITY

VANITY

143 VANITY

VANITY

VANITY

VANITY

2 BED UNIT

2 BED UNIT

3307 2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

2 BED UNIT

VANITY

2 BED UNIT

2 BED UNIT

VANITY

VANITY

2 BED UNIT

2 BED UNIT

VANITY

VANITY

2 BED UNIT

VANITY

RA UNIT

2 BED UNIT

2 BED UNIT

VANITY

VANITY

2 BED UNIT

2 BED UNIT

VANITY

VANITY

CORRIDOR

CORRIDOR

GATHERING

GATHERING

GATHERING

CORRIDOR

ELEC

RECYCLING

JAN

ELEC

STAIRS

RR

RR

RR

RR

RR

142 RR

RR

RR

RR

RR

RR

RR

176RR

RR

RR

RR

RR

RR

RR

800 800

A

.1

A

.1

A

.1

Revisions:

A u st in

S a n A n to n io

H o u s to n

B a rt o n

S p ri n g s

R o a d

S u it e

A u st in Te xa s

B ro a d w a y S u it e

S a n A n to n io

Te xa s

F a n n in

S tr e e t, S u it e

H o u st o n Te xa s p

.4

.7 f

.4

.7 p

.2

.6 f

.2

.6 p

.4

.1 f

.4

.1

A u to d e s k D o c s /A n g e lo S ta te

U n iv e rs it y /2

A

S U

P la z a V e rd e B ld g

-H

V A

C R p lm n t_

A R

C H

C e n tr a l.

rv t

/2

/2

:2

:3

A

M

P L

A Z

A V

E R

D E

B L

D G

H

V A

C R

E P

L A

C E

M E

N T

S

S V

A N

B U

R E N

S T, S A

N A

N G

E

LO

TX

A N

G E

LO

S

TA

TE

U

N

IV

E R

S

IT

Y

07/24/2026

Project No. 2574.02

CONTRACT DOCUMENTS

REFLECTED CEILING

PLAN

A9.2

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

KEYNOTE LEGEND

800 REFINISH EXISTING CROWN MOLDING IN PT4.

RCP LEGEND

GENERAL RCP NOTES

SCALE: 1/8" = 1'-0"

REFLECTED CEILING PLAN - LEVEL 2

SCALE: 1/8" = 1'-0"

REFLECTED CEILING PLAN - LEVEL 3

1. REFER TO THE LIST OF FINISHES FOR ALL

FINISH DESIGNATIONS. FINISH PLANS TO BE

USED WHEN MORE THAN ONE FINISH IS USED

IN A ROOM.

2. PT1 AT ALL WALLS U.N.O.

3. RE-FINISH EXISTING CRASH RAILS IN PT4.

XX EXTENTS OF FINISH

ROOM NAME

ROOM #

WALL FINISH

XXX

CHANGE IN FLOORING TYPE -

TRANSITION NEEDED

EXISTING FLOORING

CP1

NOTE: HATCHES SHOWN ON PLANS ARE

REPRESENTATIONAL AND ONLY SIGNIFY EXTENT OF

FINISH UNLESS STARTING POINT IS SHOWN.

OUT OF SCOPE

GRAIN DIRECTION

N

TRUE NORTH

N

PLAN NORTH

CORRIDOR

PT1

CORRIDOR

PT1

CORRIDOR

PT1

GATHERING

GATHERING

GATHERING

2 BED UNIT

PT1

2 BED UNIT

PT1

2 BED UNIT

PT1

2 BED UNIT

PT1

2 BED UNIT

PT1

ACCESSIBLE

UNIT

PT1

2 BED UNIT

PT1

ACCESSIBLE

UNIT

PT1

2 BED UNIT

PT1

2 BED UNIT

PT1

RA UNIT

PT13108

2 BED UNIT

PT1

2 BED UNIT

PT1

2 BED UNIT

PT1

2 BED UNIT

PT1

2 BED UNIT

PT1

2 BED UNIT

PT1

TEAM ROOM

PT1

LAUNDRY

PT1

RR

PT1

RR

PT1 39

RR

PT1

RR

PT1

RR

PT1

RR

PT1

RR

PT1

RR

PT1

RR

PT1

RR

PT1

RR

PT1

RR

PT1

RR

PT1

RR

PT1

RR

PT1

RR

PT1

RR

PT1

VANITY

PT1

VANITY

PT1 56

VANITY

PT1

VANITY

PT1

VANITY

PT1

VANITY

PT1

VANITY

PT1

VANITY

PT164

VANITY

PT1

VANITY

PT166

VANITY

PT1

VANITY

PT1

VANITY

PT1

VANITY

PT1

VANITY

PT1

VANITY

PT1

A10.1

A10.1

3 OH

A10.1

3 OH

A10.1

3 OH

A10.1

3 A10.1

A10.1

A10.1

3 OH

A10.1

A10.1

A10.1

A10.1

3 OH

A10.1

3 OH A10.1

3 OH

A10.1

3 OH3 OH 3

3120A

ELEV. MACH.

RM.

PT1

3120C

SPRINKLER RM

PT1

STAIRS

PT1

MECH

PT1

JAN/ELEC

PT1

ELEC

PT1

ELEC

PT1

PT4 PT4 PT4 PT4

A10.1 4 A10.14

900900 900

RB1 RB1

RB1

RB1 RB1

RB1

RB1 RB1

RB1

RB1

RB1

PT4

1'-0"

A L

IG

N

EXISTING

SIGNAGE

EXISTING

CRASH RAIL

LIFT AND RE-ADHERE

EXISTING RESILIENT

FLOORING

METAL EDGE TRIM BY TARKETT

CARPET AS SPECIFIED

EQ EQ

EXISTING

T.V.

DIMENSIONAL ACRYLIC SIGNAGE

BY FAST SIGNS.

CONTACT:

ALEX CRUZ

FASTSIGNS.177@FASTSIGNS.COM

512-445-4220

E Q

E Q 3

Revisions:

A u st in

S a n A n to n io

H o u s to n

B a rt o n

S p ri n g s

R o a d

S u it e

A u st in Te xa s

B ro a d w a y S u it e

S a n A n to n io

Te xa s

F a n n in

S tr e e t, S u it e

H o u st o n Te xa s p

.4

.7 f

.4

.7 p

.2

.6 f

.2

.6 p

.4

.1 f

.4

.1

A u to d e s k D o c s /A n g e lo S ta te

U n iv e rs it y /2

A

S U

P la z a V e rd e B ld g

-H

V A

C R p lm n t_

A R

C H

C e n tr a l.

rv t

/2

/2

:2

:3

A

M

P L

A Z

A V

E R

D E

B L

D G

H

V A

C R

E P

L A

C E

M E

N T

S

S V

A N

B U

R E N

S T, S A

N A

N G

E

LO

TX

A N

G E

LO

S

TA

TE

U

N

IV

E R

S

IT

Y

07/24/2026

Project No. 2574.02

CONTRACT DOCUMENTS

ROOM FINISH PLAN

A10.1

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

GENERAL FINISH

PLAN NOTES

INTERIOR FINISH LEGEND

SCALE: 1/8" = 1'-0"

FINISH PLAN - LEVEL 1

LIST OF FINISHES

DESIGNATION DESCRIPTION MANUFACTURER/PRODUCT COLOR/NAME INSTALLATION/PATTERN STYLE REMARKS

PAINT

PT1 PAINT - FIELD COLOR SHERWIN WILLIAMS AGREEABLE GRAY 7029 N/A GENERAL FIELD COLOR

PT2 PAINT SHERWIN WILLIAMS HIGH REFLECTIVE WHITE 7757 N/A GYP CEILING U.N.O.

PT3 PAINT SHERWIN WILLIAMS MANOR HOUSE 7505 N/A DOORS U.N.O.

PT4 PAINT SHERWIN WILLIAMS OR SIMILAR MATCH WAVY NAVY BY KELLY MOORE N/A HM DOOR FRAME COLOR AND

ACCENT U.N.O.

BASE

RB1 4" BASE MATCH EXISTING MATCH EXISTING N/A

CARPET

CP1 18"X36" CARPET TILE TARKETT NIGHTSIDE 52601, EARTHBOUND VERTICAL ASHLAR INSTALL METHOD

SCALE: 1/2" = 1'-0"

TYP. STUDENT DOOR ACCENT

3SCALE: 12" = 1'-0"2

FLOORING TRANSITION -

CARPET TO RESILIENT

SCALE: 1/2" = 1'-0"

TYP. DISPLAY WALL

KEYNOTE LEGEND

900 NEW CARPET AND BASE TO BE INSTALLED WITHIN THE

EXISTING EXTENTS OF DEMOLISHED FLOOR FINISH.

UP

DN

N

TRUE NORTH

N

PLAN NORTH

2 BED UNIT

PT1

2 BED UNIT

PT1

VANITY

PT1

RR

PT1

RR

PT1

VANITY

PT1

2 BED UNIT

PT1

2 BED UNIT

PT1

VANITY

PT1

RR

PT1

RR

PT1

VANITY

PT1

2 BED UNIT

PT1

2 BED UNIT

PT1

VANITY

PT1

RR

PT1

RR

PT1

VANITY

PT1

2 BED UNIT

PT1

2 BED UNIT

PT1

VANITY

PT1

RR

PT1

RR

PT1

VANITY

PT1

2 BED UNIT

PT1

VANITY

PT1

RR

PT1

2 BED UNIT

PT1

2 BED UNIT

PT1

VANITY

PT1

RR

PT1

RR

PT1

VANITY

PT1

VANITY

PT1

RR

PT1

2 BED UNIT

PT1

2 BED UNIT

PT1

RR

PT1

VANITY

PT1

VANITY

PT1

RR

PT1

2 BED UNIT

PT1

RA UNIT

PT1

RR

PT1

VANITY

PT1

RR

PT1

RR

PT1

2 BED UNIT

PT1

2 BED UNIT

PT1

VANITY

PT1

2 BED UNIT

PT1

2 BED UNIT

PT1

VANITY

PT1

RR

PT1

RR

PT1

VANITY

PT1

CORRIDOR

PT1

CORRIDOR

PT1

CORRIDOR

PT1

GATHERING

GATHERING

GATHERING

A10.1

A10.1

3 A10.1

A10.1

A10.1

A10.1

3 OH

A10.1

3 OH

A10.1

3 OH A10.1

3 OH

A10.1

3 OH

A10.1

33 OH 3 OH

A10.1

3 OH

A10.1

3 OH A10.1

3 OH

A10.1

3 A10.1

STAIRS

PT1

ELEC

PT1

IDF

PT1

JAN/ELEC

PT1

MECH

PT1

PT4 PT4PT4 PT4

RB1 RB1

A10.1 4 A10.14 A10.1 4 A10.14

900900 900

RB1

RB1

RB1

RB1

RB1

RB1

RB1

RB1

RB1

RB1

OH

OH

OH

OH

OH

OH OH

OH

OH

OH

A10.1

A10.1

3 A10.1

A10.1

A10.1

A10.1

A10.1

A10.1

3 A10.1

A10.1

A10.1

33 3

A10.1

A10.1

3 A10.1

A10.1

3 A10.1

2 BED UNIT

PT1

2 BED UNIT

PT1

VANITY

PT1

RR

PT1

RR

PT1

VANITY

PT1

2 BED UNIT

PT1

2 BED UNIT

PT1

VANITY

PT1

RR

PT1

RR

PT1

VANITY

PT1

2 BED UNIT

PT1

2 BED UNIT

PT1

VANITY

PT1

RR

PT1

RR

PT1

VANITY

PT1

2 BED UNIT

PT1

2 BED UNIT

PT1

VANITY

PT1

RR

PT1

RR

PT1

VANITY

PT1

2 BED UNIT

PT1

VANITY

PT1

RR

PT1

2 BED UNIT

PT1

2 BED UNIT

PT1

VANITY

PT1

RR

PT1

RR

PT1

VANITY

PT1

VANITY

PT1

RR

PT1

2 BED UNIT

PT1

2 BED UNIT

PT1

RR

PT1

VANITY

PT1

VANITY

PT1

RR

PT1

2 BED UNIT

PT1

RA UNIT

PT1

RR

PT1

VANITY

PT1

RR

PT1

RR

PT1

2 BED UNIT

PT1

2 BED UNIT

PT1

VANITY

PT1

2 BED UNIT

PT1

2 BED UNIT

PT1

VANITY

PT1

RR

PT1

RR

PT1

VANITY

PT1

CORRIDOR

PT1

CORRIDOR

PT1

CORRIDOR

PT1

GATHERING

GATHERING

GATHERING

STAIRS

PT1

ELEC

PT1

RECYCLING

PT1

JAN

PT1

ELEC

PT1

PT4 PT4 PT4 PT4

RB1 RB1

A10.1 4 A10.14 A10.1 4 A10.14

900900 900

RB1

RB1

RB1

RB1

RB1

RB1

RB1

RB1

RB1

RB1

1. REFER TO THE LIST OF FINISHES FOR ALL

FINISH DESIGNATIONS. FINISH PLANS TO BE

USED WHEN MORE THAN ONE FINISH IS USED

IN A ROOM.

2. PT1 AT ALL WALLS U.N.O.

3. RE-FINISH EXISTING CRASH RAILS IN PT4.

XX EXTENTS OF FINISH

ROOM NAME

ROOM #

WALL FINISH

XXX

CHANGE IN FLOORING TYPE -

TRANSITION NEEDED

EXISTING FLOORING

CP1

NOTE: HATCHES SHOWN ON PLANS ARE

REPRESENTATIONAL AND ONLY SIGNIFY EXTENT OF

FINISH UNLESS STARTING POINT IS SHOWN.

OUT OF SCOPE

GRAIN DIRECTION

Revisions:

A u st in

S a n A n to n io

H o u s to n

B a rt o n

S p ri n g s

R o a d

S u it e

A u st in Te xa s

B ro a d w a y S u it e

S a n A n to n io

Te xa s

F a n n in

S tr e e t, S u it e

H o u st o n Te xa s p

.4

.7 f

.4

.7 p

.2

.6 f

.2

.6 p

.4

.1 f

.4

.1

A u to d e s k D o c s /A n g e lo S ta te

U n iv e rs it y /2

A

S U

P la z a V e rd e B ld g

-H

V A

C R p lm n t_

A R

C H

C e n tr a l.

rv t

/2

/2

:2

:4

A

M

P L

A Z

A V

E R

D E

B L

D G

H

V A

C R

E P

L A

C E

M E

N T

S

S V

A N

B U

R E N

S T, S A

N A

N G

E

LO

TX

A N

G E

LO

S

TA

TE

U

N

IV

E R

S

IT

Y

07/24/2026

Project No. 2574.02

CONTRACT DOCUMENTS

ROOM FINISH PLAN

A10.2

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

O

'C O

N N

E

LL

R O

B E R

TS

O

N

IN

C

SCALE: 1/8" = 1'-0"

FINISH PLAN - LEVEL 2

SCALE: 1/8" = 1'-0"

FINISH PLAN - LEVEL 3

GENERAL FINISH

PLAN NOTES

INTERIOR FINISH LEGEND

KEYNOTE LEGEND

900 NEW CARPET AND BASE TO BE INSTALLED WITHIN THE

EXISTING EXTENTS OF DEMOLISHED FLOOR FINISH.

A.E

A.D

A.G

A.C

A.F

A.B

A.A

9' -1

'-1

3/ 8"

9' -1

'-1

1/

8"

1' -4

2'

-2

/2

5' -7

'-2

/4

1' -4

182'-1 1/4"

'-2

12K3

16K3 14K3

16K3

9' -1

'-1

3/ 8"

9' -1

16K4 10 K1

K1

K4

HSS 10X4X1/4

HSS 10X4X1/4

H

SS

0X

4X 1/

H

SS

0X

4X 1/

W12X16W14X22 W12X14 W14X22

W12X16 W14X22

W12X16 W14X22 W

X1

W

X1

W

X1

W

X1

W

X1

W

X1

W

X1

W12X16W14X22

W

X1

W

X1

W

X1

W

X1

W

X1

W

X1

W

X1

W12X14 W14X22

W14X22 W12X16 RIDGE LINE

12K3

4 EQ. SPA.

SL

O

PE

SL

O

PE

12K3

RIDGE LINE

CU-3101

12K3 12K3

HRU-1

WEIGHT AND

FOOTPRINT TO

MATCH EXISTING

16K4

HRU-2

WEIGHT AND

FOOTPRINT TO

MATCH EXISTING

10K1

CU-3103

CU-3130

CU-3129

CU-3102

CU-3104

CU-3201

CU-3203

CU-3229

CU-3230

CU-3329

CU-3202

CU-3330CU-3204

CU-3303

CU-3301

CU-3304

CU-3302

CU-3305

CU-3227

CU-3105

CU-3207

CU-3307

CU-3306

CU-3206

CU-3308

CU-3208

CU-3205

CU-3107

CU-3127

CU-3327

CU-3106 CU-3108

CU-3209

CU-3109

CU-3111

CU-3211

CU-3324

CU-3310

CU-3210

CU-3312

CU-3212

CU-3110

CU-3124

CU-3112

CU-3224

CU-3309 CU-3311

CU-3316

CU-3314

CU-3116CU-3114

CU-3216

CU-3214

CU-3213

CU-3113 CU-3115

CU-3222 CU-3322

CU-3313

CU-3315CU-3215CU-3122

CU-3317

CU-3117

CU-3131

CU-3132

CU-3118

CU-3120

CU-3231

CU-3331

CU-3219

CU-3332

CU-3318

CU-3320

CU-3217

CU-3220

CU-3232

CU-3319

CU-3119

A.11 A.1 A.2 A.3 A.4 A.5 A.6 A.7 A.8 A.9A.10

CU-3218

CU-3120-A

18'-6" 19'-11 5/8" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 19'-0 5/8"

'-0

/8

2' -2

/2

35'-10 1/2" 38'-4 1/4" 33'-7 3/4" 38'-4 1/4" 35'-10 1/2"

12K3

12K3

12K3

NOTES:

1.

2.

3.

4.

THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO CONSTRUCTION.

THE ROOF FRAMING SHOWN ON THIS PLAN IS EXISTING WITH LAYOUT AND MEMBER SIZES PER THE DRAWINGS

PROVIDED TO US.

REFER TO ARCHITECTURAL AND MEP DRAWINGS FOR INFORMATION NOT SHOWN ON THIS PLAN.

IF NEW HEAT RECOVERY UNITS AND/OR CONDENSING UNITS ARE PROCURED THAT ARE HEAVIER THAN SHOWN ON

THIS PLAN, CONTACT SKG ENGINEERING FOR VERIFICATION PRIOR TO INSTALLATION.

APPROX. (FIELD VERIFY)

2'-0" SQ.

6" LAP 6" LAP EXST. 1 1/2" 20GA TYPE B

ROOF DECK

PROVIDE NEW

1 1/2" 20GA, TYPE B

ROOF DECK INFILL

SCREW END LAPS TO

EXISTING B/W EACH RIB

AND SIDE LAPS @ 6" OC

USING #10 TEKS.

INSULATE AND ROOF PER

ARCHITECTURE.

EXISTING FRAMING

(5) LOCATIONS AT EXISTING ROOF PENETRATIONS

FOR EXISTING…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .