ESBD_533035_1782845702577_Attachment 7 - Asbestos Report.pdf

PDF 2 MB Posted

Attached to
CCRC Kitchen Cooler Remediation
Solicitation number
3202600220
Issued by
Travis County, Austin City, Texas

About this file

This is a Limited Asbestos Survey Report prepared by Environmental & Construction Services, Inc. (ERC) for the Texas Workforce Commission (TWC) related to the CCRC Building Cooler/Freezer Project located at 4800 Lamar Boulevard in Austin, Texas. The survey was conducted on March 3, 2020, to identify asbestos-containing building materials (ACBM) in preparation for the installation of new cooler and freezer units in an approximately 1,000 square-foot interior area. The project also required roof sampling due to necessary penetrations through the roof structure. ERC, a licensed environmental and construction services firm, collected a total of 12 bulk material samples from various locations including roofing materials, caulking, concrete decks, and plaster ceilings. All samples were submitted to an approved laboratory (EMSL Analytical, Inc.) for analysis using Polarized Light Microscopy (PLM) in accordance with EPA 600/R-93/116 methodology.

The survey results, completed on March 11, 2020, revealed no asbestos-containing materials in any of the 12 samples analyzed. All samples tested negative (ND) for asbestos content with non-friable (NF) classifications and conditions ranging from good to damaged. The roofing materials, caulking compounds, concrete decks, and plaster ceilings were found to contain only non-asbestos components such as cellulose, synthetic materials, glass, calcium carbonate, and other non-fibrous materials. While the survey did not identify any ACBM, ERC recommended that any inaccessible or unidentified materials exposed during future renovation and demolition activities be sampled and evaluated. The City of Austin Development Services Department was notified of the survey completion on March 10, 2020, in compliance with Senate Bill 509 requirements for asbestos testing prior to issuing renovation or demolition permits.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ENVIRONMENTAL & CONSTRUCTION SERVICES, INC.

H O U S T O N • A U S T I N • D A L L A S www.erc-tx.com

Limited Asbestos Survey Report

Texas Workforce Commission CCRC Building – Freezer/Cooler Project

ERC Project No. 02001024.03.01

ERC Electronic Front Report Cover

© Copyright 1991-2020 by ERC Environmental & Construction Services, Inc. (ERC)

DISCLAIMER

The information contained in this report is confidential, privileged, and only for the information of the CLIENT as identified in the Project Directory. This report may be provided to a third party but must be provided in whole; however, ERC’s liability for the information contained in this report does not extend beyond the CLIENT, unless ERC agrees, in writing to such extension.

The professional opinions expressed in this report are in good faith and while every care has been taken in preparing this document, any decision made based in whole, or in part, on this report should be discussed with ERC prior to implementation. ERC Environmental & Construction Services, Inc., its subsidiaries, the directors, employees, and agents cannot be held liable for decisions made in opposition to the recommendations contained in this report.

SURVEY REPORT

LIMITED ASBESTOS

PROJECT

CCRC Building

Austin, TX

REPORT DATE

March 11, 2020

ERC PROJECT#

02001024.03.01

PREPARED FOR

Texas Workforce Commission

Austin, TX

PREPARED BY

ERC

Houston, TX

TABLE OF CONTENTS

TWC | CCRC Building ERC Project #02001024.03.01

PAGE

SECTION 1: Project Directory 1

SECTION 2: Limited Asbestos Survey Report 2

SECTION 3: Photos 4

SECTION 4: Drawings 2 Pages

SECTION 5: City Permit Letter

APPENDICES:

A) ERC Licenses B) Lab Results C) Asbestos Glossary

SECTION 1

PROJECT DIRECTORY

SECTION 1: PROJECT DIRECTORY

TWC | CCRC Building ERC Project #02001024.03.01 Page 1

PROJECT: CCRC Building New Cooler/Freezer Project

Limited Asbestos Survey Report 4800 Lamar Blvd Austin, TX 78756

ERC PROJECT #: 02001024.03.01

OWNER: Texas Workforce Commission

CONTACT: Mr. John Childress Manager Construction & Facilities Management 101 E 15th St, Rm 109 Austin, TX 78778 Phone #: 512-463-6064 Email Address: john.childress@twc.state.tx.us

CONSULTANT: ERC Environmental & Construction Services, Inc.

10801 Hammerly Boulevard, Suite 100 Houston, TX 77043 Phone: 713-290-9444

CONTACT: Mathew Montazari Field Engineer

DSHS Asbestos Inspector License #602920 Expires: 10/19/2020

Shelly Horan, AIMP Project Coordinator DSHS Asbestos Management Planner License #205750 Expires: July 29, 2021 Email Address: shoran@erc-tx.com

Kommy M. Azarpour, AMC, AIC, CAPM, PE President DSHS Asbestos Consultant License #105238 Expires: April 27, 2021 Email Address: kazarpour@erc-tx.com mailto:john.childress@twc.state.tx.us http://www.erc-tx.com/ mailto:shoran@erc-tx.com

SECTION 2

LIMITED ASBESTOS SURVEY

REPORT

TWC | CCRC Building ERC Project #02001024.03.01 Page 2

LIMITED ASBESTOS SURVEY REPORT

SAMPLE DATE: March 3, 2020

CLIENT: Texas Workforce Commission

PROJECT NAME: CCRC Building – New Cooler/Freezer Project

ERC PROJECT NUMBER: 02001024.03.01

IDENTIFICATION: Asbestos Analysis-Bulk Material Sampling

METHOD OF TEST: PLM / DS EPA 600/R-93/116

On March 3, 2020, a representative of ERC Environmental & Construction Services, Inc.

(ERC), was at the above referenced project to conduct an inspection and limited bulk material sampling. This work was requested and authorized by Mr. Randall Price of Texas Workforce Commission (TWC).

The building consists of multiple connected buildings, ranging from one-story to three-stories. The building of concern is a single-story building. It is ERCs understanding that the purpose of this survey is in preparation for new cooler/freezers to be installed. The interior area of concern, where the new cooler/freezers are to be installed, is approximately 1,000 square feet. Additionally, because new penetrations through the roof of the buildings will be necessary, roof samples were collected. As part of this process, TWC arranged for a roofer to follow our inspector to patch the areas where these samples were collected (see photos).

A total of 12 bulk samples were collected and submitted for analysis by Polarized Light Microscopy (PLM) for asbestos content. Results of analysis are summarized below.

Please see attached laboratory data sheets for detail result analysis.

Results Summary

SAMPLE

NUMBER

TYPE / LOCATION

ASBESTOS

FRIABILITY CONDITION

AB-01

Roofing Material; White & Black / Big Building

ND NF G

AB-02

Roofing Material; White & Black / Small Building

ND NF G

AB-03

Roofing Material; White & Black / Small Building

ND NF G

SECTION 2: LIMITED ASBESTOS SURVEY REPORT

TWC | CCRC Building ERC Project #02001024.03.01 Page 3

SAMPLE

NUMBER

TYPE / LOCATION

ASBESTOS

FRIABILITY CONDITION

AB-04

Roofing Material; Calking; Off- White / by A/C Units on Small Roof Top

ND NF D

AB-05

Roofing Material; Calking; Off- White / by A/C Units on Small Roof Top

ND NF D

AB-06

Roofing Material; Calking; Off- White / by A/C Units on Small Roof Top

ND NF D

AB-07

Concrete Deck / In Small Building

ND NF G

AB-08

Concrete Deck / In Small Building

ND NF G

AB-09

Concrete Deck / In Small Building

ND NF G

AB-10

Plaster Ceiling / In Big Building

ND NF D

AB-11

Plaster Ceiling / In Big Building

ND NF D

AB-12

Plaster Ceiling / In Big Building

ND NF D

LEGEND

D Damaged F Friable G Good

NF Non-Friable ND None Detected

POSITIVE FOR ASBESTOS

Summary of Findings

Our survey did not reveal the presence of Asbestos-Containing Building Material

(ACBM).

Recommendations

While no asbestos-containing materials were found during this survey, it is possible that inaccessible or unidentified materials may be exposed during any renovation and/or demolition activities. Such materials should then be sampled and evaluated.

Please advise should you have any questions about this report or if you need further assistance with this project.

SECTION 3

PHOTOS

SECTION 3: PHOTOS

TWC | CCRC Building ERC Project #02001024.03.01 Page 4

TWC CCRC Building – 4800 North Lamar

Roof Condition

TWC | CCRC Building ERC Project #02001024.03.01 Page 5

Location of Roof Sampling

Roof Sampling

TWC | CCRC Building ERC Project #02001024.03.01 Page 6

Roof Patching

Roof Patching

TWC | CCRC Building ERC Project #02001024.03.01 Page 7

Roofing Material - Caulking

Concrete Deck Sampling

TWC | CCRC Building ERC Project #02001024.03.01 Page 8

Plaster Ceiling Sampling

SECTION 4

DRAWINGS

E n v i r o n m e n t a l

C o n s t r u c t i o n

S e r v i c e s

I n c

SHEET - 1

C C

R

B

U I L

D I N

G

F

I R

S T

F

L O

O

P

L A

N

D

M

O

N

T E

X A

S

W

O R

K F

O R

M

M I S

S I O

N

AB-XX

AB-XX

AB-06

AB-07

AB-08

AB-09

AB-05

AB-04

AB-12

AB-11

AB-10

AutoCAD SHX Text

DRAWING NUMBER:

AutoCAD SHX Text

ERC PROJECT NUMBER:

AutoCAD SHX Text

CONSTRUCTION SERVICES, INC.

AutoCAD SHX Text

ENVIRONMENTAL &

AutoCAD SHX Text

FILE:

AutoCAD SHX Text

SCALE +/-:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

REV BY:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DWG BY:

AutoCAD SHX Text

OF

AutoCAD SHX Text

4800 N LAMAR BLVD., AUSTIN, TX 78756

AutoCAD SHX Text

AUSTIN, TX 78756

AutoCAD SHX Text

2828 FOREST LANE, SUITE 1147

AutoCAD SHX Text

DALLAS, TEXAS 75234

AutoCAD SHX Text

PHONE: 972-243-2177 FAX: 972-243-2179

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

KYL

AutoCAD SHX Text

KA

AutoCAD SHX Text 02001024.03.01

AutoCAD SHX Text

12MAR20

AutoCAD SHX Text

12MAR20

AutoCAD SHX Text 02001024.03.01

AutoCAD SHX Text

INDICATES POSITIVE ASBESTOS SAMPLE LOCATIONS

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text

INDICATES NEGATIVE ASBESTOS SAMPLE LOCATIONS

n v i r o n m e n t a l o n s t r u c t i o n

S e r v i c e s

I n c

SHEET - 2

C C

B

U I L

D I N

G

M

P

O

F

P

L A

N

D

E M

O

N

T E

X A

S

W

O R

K F

O R

M

M I S

S I O

N

AB-02

AB-XX

AB-XX

AB-03

AB-01

AutoCAD SHX Text

DRAWING NUMBER:

AutoCAD SHX Text

ERC PROJECT NUMBER:

AutoCAD SHX Text

CONSTRUCTION SERVICES, INC.

AutoCAD SHX Text

ENVIRONMENTAL &

AutoCAD SHX Text

FILE:

AutoCAD SHX Text

SCALE +/-:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

REV BY:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DWG BY:

AutoCAD SHX Text

OF

AutoCAD SHX Text

4800 N LAMAR BLVD., AUSTIN, TX 78756

AutoCAD SHX Text

AUSTIN, TX 78756

AutoCAD SHX Text

2828 FOREST LANE, SUITE 1147

AutoCAD SHX Text

DALLAS, TEXAS 75234

AutoCAD SHX Text

PHONE: 972-243-2177 FAX: 972-243-2179

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

KYL

AutoCAD SHX Text

KA

AutoCAD SHX Text 02001024.03.01

AutoCAD SHX Text

12MAR20

AutoCAD SHX Text

12MAR20

AutoCAD SHX Text 02001024.03.01

AutoCAD SHX Text

INDICATES POSITIVE ASBESTOS SAMPLE LOCATIONS

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text

INDICATES NEGATIVE ASBESTOS SAMPLE LOCATIONS

SECTION 5

CITY PERMIT LETTER

March 10, 2020

City of Austin Development Services Department 505 Barton Springs Rd Austin, TX 78704

Re: ERC Project No. 2001024.03.01

Asbestos Survey CCRC Building – Cooler/Freezer Project 4800 N Lamar Blvd Austin, TX 78756

To Whom It May Concern:

On March 2, 2020 a limited building material survey for asbestos-containing material (ACM) was conducted at the above referenced location. The site assessment and material testing addressed all the areas to be impacted by the remodeling and construction work at this location, to comply with Senate bill 509 pertaining to the requirement for asbestos testing prior to the issuance of permits for renovation or demolition by the municipalities. The asbestos survey was conducted by a Texas Department of State Health Services (DSHS) licensed inspector, Mathew Montazari, License No. 602920. Samples were submitted to an approved laboratory (NVLAP) for analysis by Polarized Light Microscopy (PLM). This work was requested and authorized by Mr. Randall Price of Texas Workforce Commission (TWC).

All renovations or demolition activities which could disturb the ACM must be avoided until all asbestos-containing materials have been addressed.

Should you have any questions about this project or this letter, please do not hesitate to call my office at your earliest convenience at 713-290-9444.

Respectfully submitted, ERC

Shelly Horan, AIMP Project Coordinator DSHS Asbestos Management Planner License #205750 Expires: July 29, 2021

APPENDIX A

ERC LICENSES

APPENDIX A: ERC LICENSES

APPENDIX B

LAB RESULTS

EMSL Analytical, Inc.

5950 Fairbanks N. Houston Rd. Houston, TX 77040

Tel/Fax: (713) 686-3635 / (713) 686-3645 http://www.EMSL.com / houstonlab@emsl.com

152001607EMSL Order:

Customer ID: ERC50

Customer PO:

Project ID:

Attention: Phone:Shelly (713) 290-9444

Fax:ERC (713) 290-9441

Received Date:10801 Hammerly Blvd. 03/03/2020 4:15 PM

Analysis Date:Suite 100 03/05/2020 - 03/06/2020

Collected Date:Houston, TX 77043

Project: 02001024.03.01 / 4800 N. Lamar Blvd

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

AB01-Roofing

152001607-0001

None DetectedNon-fibrous (Other)45%Cellulose

Synthetic

Glass

30%

15%

10%

Gray/White/Black

Non-Fibrous

Homogeneous

Roofing Material /

White and Black

AB01-Foam

152001607-0001A

None DetectedNon-fibrous (Other)100%Beige

Non-Fibrous

Homogeneous

Roofing Material /

White and Black

AB02-Roofing

152001607-0002

None DetectedNon-fibrous (Other)45%Cellulose

Synthetic

Glass

30%

15%

10%

Gray/White/Black

Fibrous

Homogeneous

Roofing Material /

White and Black

AB02-Foam

152001607-0002A

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Roofing Material /

White and Black

AB02-Insulation 1

152001607-0002B

None DetectedNon-fibrous (Other)20%Cellulose80%Beige

Fibrous

Homogeneous

Roofing Material /

White and Black

AB02-Insulation 2

152001607-0002C

None DetectedMica

Non-fibrous (Other)

15%

85%

White

Non-Fibrous

Homogeneous

Roofing Material /

White and Black

AB03-Roofing 1

152001607-0003

None DetectedNon-fibrous (Other)80%Glass20%Black

Fibrous

Homogeneous

Roofing Material /

White and Black

AB03-Roofing 2

152001607-0003A

None DetectedNon-fibrous (Other)80%Cellulose

Glass

10%

10%

Black

Fibrous

Homogeneous

Roofing Material /

White and Black

AB03-Roofing 3

152001607-0003B

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Roofing Material /

White and Black

AB03-Insulation 1

152001607-0003C

None DetectedNon-fibrous (Other)10%Cellulose90%Beige

Fibrous

Homogeneous

Roofing Material /

White and Black

AB03-Foam

152001607-0003D

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Roofing Material /

White and Black

AB03-Felt

152001607-0003E

None DetectedNon-fibrous (Other)30%Cellulose70%Brown

Fibrous

Homogeneous

Roofing Material /

White and Black

AB03-Insulation 2

152001607-0003F

None DetectedCa Carbonate

Matrix

Non-fibrous (Other)

10%

15%

75%

White

Non-Fibrous

Homogeneous

Roofing Material /

White and Black

AB03-Roofing 4

152001607-0003G

None DetectedNon-fibrous (Other)55%Cellulose

Synthetic

30%

15%

Brown/White/Black

Fibrous

Heterogeneous

Roofing Material /

White and Black

AB04

152001607-0004

None DetectedNon-fibrous (Other)100%Gray/Beige

Non-Fibrous

Homogeneous

Roofing Caulking /

Gray - Off White

AB05

152001607-0005

None DetectedNon-fibrous (Other)100%Gray/Beige

Non-Fibrous

Homogeneous

Roofing Caulking /

Gray - Off White

Initial report from: 03/06/2020 12:43:03

Page 1 of 2ASB_PLM_0008_0001 - 1.78 Printed: 3/6/2020 11:43 AM

EMSL Analytical, Inc.

5950 Fairbanks N. Houston Rd. Houston, TX 77040

Tel/Fax: (713) 686-3635 / (713) 686-3645 http://www.EMSL.com / houstonlab@emsl.com

152001607EMSL Order:

Customer ID: ERC50

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

AB06

152001607-0006

None DetectedCa Carbonate

Non-fibrous (Other)

5%

95%

Gray/Beige

Non-Fibrous

Homogeneous

Roofing Caulking /

Gray - Off White

AB07

152001607-0007

None DetectedCa Carbonate

Non-fibrous (Other)

10%

90%

Brown/Gray/Beige

Non-Fibrous

Homogeneous

Concrete Deck Inside

Small Building

AB08

152001607-0008

None DetectedCa Carbonate

Non-fibrous (Other)

10%

90%

Brown/Gray/Beige

Non-Fibrous

Homogeneous

Concrete Deck Inside

Small Building

AB09

152001607-0009

None DetectedCa Carbonate

Non-fibrous (Other)

20%

80%

Gray/Beige

Non-Fibrous

Heterogeneous

Concrete Deck Inside

Small Building

Inseparable paint / coating layer included in analysis

AB10

152001607-0010

None DetectedCa Carbonate

Non-fibrous (Other)

20%

80%

Brown/White/Beige

Non-Fibrous

Heterogeneous

Plaster Ceiling -

Inside Big Building

Inseparable paint / coating layer included in analysis

AB11

152001607-0011

None DetectedCa Carbonate

Non-fibrous (Other)

20%

80%

Brown/White/Beige

Non-Fibrous

Heterogeneous

Plaster Ceiling -

Inside Big Building

Inseparable paint / coating layer included in analysis

AB12

152001607-0012

None DetectedCa Carbonate

Non-fibrous (Other)

20%

80%

White/Beige

Non-Fibrous

Heterogeneous

Plaster Ceiling -

Inside Big Building

Inseparable paint / coating layer included in analysis

Analyst(s)

Jenny Drapela (11)

Wanda Porch (12)

Michelle Leggett, Laboratory Manager or Other Approved Signatory

EMSL maintains liability limited to cost of analysis . The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 "Interim

Method"), but augmented with procedures outlined in the 1993 ("final") version of the method. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . Interpretation and use of test results are the responsibility of the client. All samples received in acceptable condition unless otherwise noted. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. EMSL recommends gravimetric reduction for all non -friable organically bound materials prior to analysis. Estimation of uncertainty is available on request.

Samples analyzed by EMSL Analytical, Inc. Houston, TX NVLAP Lab Code 102106-0, AZ 0925, CO AL-15355, LA 04126, TX 300159

Initial report from: 03/06/2020 12:43:03

Page 2 of 2ASB_PLM_0008_0001 - 1.78 Printed: 3/6/2020 11:43 AM

APPENDIX C

ASBESTOS GLOSSARY

APPENDIX C: ASBESTOS GLOSSARY

ACBM – Asbestos-Containing Building Materials. Materials containing greater than 1% asbestos, by weight and utilized in building construction. (Measured By PLM.)

ACM – Asbestos-Containing Materials.

AECP – Asbestos Exposure Control Program also referred to as an O & M (Operations and Maintenance) Program.

AHERA – Asbestos Hazard Emergency Response Act signed into law in 1986. The law directs EPA to promulgate regulations for addressing asbestos problems in public and private schools, grades K-12.

Asbestos – Naturally occurring fibrous minerals composed of hydrated silicates, crystalline in structure, occurring as parallel bundles. Two categories: Serpentine (Chrysotile) and Amphibole (Amosite, Anthophylite, Tremolite, Crocidolite, Actinolite).

Friable – Materials that, at present, can be crushed and/or pulverized by hand pressure.

Gypsum Board – A pre-manufactured wall surfacing substrate applied over a wood or metal framing system.

Hazard – A circumstance, mechanism or event that has the potential to create injury.

Hazard Assessment – Analysis and evaluation of physical and exposure factors to determine the need for corrective action.

Homogeneous Area – Areas having materials of the same texture, color, hardness or being of the same property.

Inspection (Survey) – The process of locating and quantifying ACM and assessing its condition.

LEA – Local Education Agency (generally the School Board).

NBS – National Bureau of Standards.

NESHAPS – National Emission Standards for Hazardous Air Pollutants.

NIOSH – National Institute for Occupation Safety and Health.

Non-Friable – Materials that, at present, cannot be crushed and/or pulverized by hand pressure. With appropriate handling techniques, non-friable material will not become friable.

OSHA – Occupational Safety and Health Administration.

APPENDIX C: ASBESTOS GLOSSARY

TWC | CCRC Building ERC Project #02001024.03.01 Page 2

PCM – Phase Contrast Microscopy - Analysis of air samples. NIOSH 7400 method is an optical microscopy fiber counting technique, which does not allow for differentiation between asbestos fibers and other types of fibers.

PEL – Permissible Exposure Limit - Level of exposure to airborne asbestos fibers above which no employee shall be exposed. The PEL is 0.10 fibers per cubic centimeter expressed as an 8-hour time-weighted average (measured by PCM). PEL's are enforced by the Occupational Safety and Health Administration (OSHA).

PLM – Polarized Light Microscopy - Analysis of bulk material samples.

Positive Stop Method – A method used by a certified laboratory. If one material is analyzed to contain asbestos content none of the other samples of that same homogenous area are analyzed.

Renovation – Altering in any way one or more facility components (except demolition).

TEM – Transmission Electron Microscopy - A high-resolution electron microscopy technique that allows for positive identification and classification of asbestos fibers. The counting technique includes only asbestos fibers.

Houston 10801 Hammerly Blvd, Ste 100

Houston, TX 77043 T: 713-290-9444 | F: 713-290-

Dallas/Fort Worth 2828 Forest Ln, Ste 1147

Dallas, TX 75234 T: 972-243-2177 | F: 972-243-

Austin 3300 Bee Cave Rd, Ste 143

Austin, TX 78746 T: 877-290-9444

ERC Electronic Back Report Cover