This is a Limited Asbestos Survey Report prepared by Environmental & Construction Services, Inc. (ERC) for the Texas Workforce Commission (TWC) related to the CCRC Building Cooler/Freezer Project located at 4800 Lamar Boulevard in Austin, Texas. The survey was conducted on March 3, 2020, to identify asbestos-containing building materials (ACBM) in preparation for the installation of new cooler and freezer units in an approximately 1,000 square-foot interior area. The project also required roof sampling due to necessary penetrations through the roof structure. ERC, a licensed environmental and construction services firm, collected a total of 12 bulk material samples from various locations including roofing materials, caulking, concrete decks, and plaster ceilings. All samples were submitted to an approved laboratory (EMSL Analytical, Inc.) for analysis using Polarized Light Microscopy (PLM) in accordance with EPA 600/R-93/116 methodology.
The survey results, completed on March 11, 2020, revealed no asbestos-containing materials in any of the 12 samples analyzed. All samples tested negative (ND) for asbestos content with non-friable (NF) classifications and conditions ranging from good to damaged. The roofing materials, caulking compounds, concrete decks, and plaster ceilings were found to contain only non-asbestos components such as cellulose, synthetic materials, glass, calcium carbonate, and other non-fibrous materials. While the survey did not identify any ACBM, ERC recommended that any inaccessible or unidentified materials exposed during future renovation and demolition activities be sampled and evaluated. The City of Austin Development Services Department was notified of the survey completion on March 10, 2020, in compliance with Senate Bill 509 requirements for asbestos testing prior to issuing renovation or demolition permits.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ENVIRONMENTAL & CONSTRUCTION SERVICES, INC.
H O U S T O N • A U S T I N • D A L L A S www.erc-tx.com
Limited Asbestos Survey Report
Texas Workforce Commission CCRC Building – Freezer/Cooler Project
ERC Project No. 02001024.03.01
ERC Electronic Front Report Cover
© Copyright 1991-2020 by ERC Environmental & Construction Services, Inc. (ERC)
DISCLAIMER
The information contained in this report is confidential, privileged, and only for the information of the CLIENT as identified in the Project Directory. This report may be provided to a third party but must be provided in whole; however, ERC’s liability for the information contained in this report does not extend beyond the CLIENT, unless ERC agrees, in writing to such extension.
The professional opinions expressed in this report are in good faith and while every care has been taken in preparing this document, any decision made based in whole, or in part, on this report should be discussed with ERC prior to implementation. ERC Environmental & Construction Services, Inc., its subsidiaries, the directors, employees, and agents cannot be held liable for decisions made in opposition to the recommendations contained in this report.
SURVEY REPORT
LIMITED ASBESTOS
PROJECT
CCRC Building
Austin, TX
REPORT DATE
March 11, 2020
ERC PROJECT#
02001024.03.01
PREPARED FOR
Texas Workforce Commission
Austin, TX
PREPARED BY
ERC
Houston, TX
TABLE OF CONTENTS
TWC | CCRC Building ERC Project #02001024.03.01
PAGE
SECTION 1: Project Directory 1
SECTION 2: Limited Asbestos Survey Report 2
SECTION 3: Photos 4
SECTION 4: Drawings 2 Pages
SECTION 5: City Permit Letter
APPENDICES:
A) ERC Licenses B) Lab Results C) Asbestos Glossary
SECTION 1
PROJECT DIRECTORY
SECTION 1: PROJECT DIRECTORY
TWC | CCRC Building ERC Project #02001024.03.01 Page 1
PROJECT: CCRC Building New Cooler/Freezer Project
Limited Asbestos Survey Report 4800 Lamar Blvd Austin, TX 78756
ERC PROJECT #: 02001024.03.01
OWNER: Texas Workforce Commission
CONTACT: Mr. John Childress Manager Construction & Facilities Management 101 E 15th St, Rm 109 Austin, TX 78778 Phone #: 512-463-6064 Email Address: john.childress@twc.state.tx.us
CONSULTANT: ERC Environmental & Construction Services, Inc.
10801 Hammerly Boulevard, Suite 100 Houston, TX 77043 Phone: 713-290-9444
CONTACT: Mathew Montazari Field Engineer
DSHS Asbestos Inspector License #602920 Expires: 10/19/2020
Shelly Horan, AIMP Project Coordinator DSHS Asbestos Management Planner License #205750 Expires: July 29, 2021 Email Address: shoran@erc-tx.com
Kommy M. Azarpour, AMC, AIC, CAPM, PE President DSHS Asbestos Consultant License #105238 Expires: April 27, 2021 Email Address: kazarpour@erc-tx.com mailto:john.childress@twc.state.tx.us http://www.erc-tx.com/ mailto:shoran@erc-tx.com
SECTION 2
LIMITED ASBESTOS SURVEY
REPORT
TWC | CCRC Building ERC Project #02001024.03.01 Page 2
LIMITED ASBESTOS SURVEY REPORT
SAMPLE DATE: March 3, 2020
CLIENT: Texas Workforce Commission
PROJECT NAME: CCRC Building – New Cooler/Freezer Project
ERC PROJECT NUMBER: 02001024.03.01
IDENTIFICATION: Asbestos Analysis-Bulk Material Sampling
METHOD OF TEST: PLM / DS EPA 600/R-93/116
On March 3, 2020, a representative of ERC Environmental & Construction Services, Inc.
(ERC), was at the above referenced project to conduct an inspection and limited bulk material sampling. This work was requested and authorized by Mr. Randall Price of Texas Workforce Commission (TWC).
The building consists of multiple connected buildings, ranging from one-story to three-stories. The building of concern is a single-story building. It is ERCs understanding that the purpose of this survey is in preparation for new cooler/freezers to be installed. The interior area of concern, where the new cooler/freezers are to be installed, is approximately 1,000 square feet. Additionally, because new penetrations through the roof of the buildings will be necessary, roof samples were collected. As part of this process, TWC arranged for a roofer to follow our inspector to patch the areas where these samples were collected (see photos).
A total of 12 bulk samples were collected and submitted for analysis by Polarized Light Microscopy (PLM) for asbestos content. Results of analysis are summarized below.
Please see attached laboratory data sheets for detail result analysis.
Results Summary
SAMPLE
NUMBER
TYPE / LOCATION
ASBESTOS
FRIABILITY CONDITION
AB-01
Roofing Material; White & Black / Big Building
ND NF G
AB-02
Roofing Material; White & Black / Small Building
ND NF G
AB-03
Roofing Material; White & Black / Small Building
ND NF G
SECTION 2: LIMITED ASBESTOS SURVEY REPORT
TWC | CCRC Building ERC Project #02001024.03.01 Page 3
SAMPLE
NUMBER
TYPE / LOCATION
ASBESTOS
FRIABILITY CONDITION
AB-04
Roofing Material; Calking; Off- White / by A/C Units on Small Roof Top
ND NF D
AB-05
Roofing Material; Calking; Off- White / by A/C Units on Small Roof Top
ND NF D
AB-06
Roofing Material; Calking; Off- White / by A/C Units on Small Roof Top
ND NF D
AB-07
Concrete Deck / In Small Building
ND NF G
AB-08
Concrete Deck / In Small Building
ND NF G
AB-09
Concrete Deck / In Small Building
ND NF G
AB-10
Plaster Ceiling / In Big Building
ND NF D
AB-11
Plaster Ceiling / In Big Building
ND NF D
AB-12
Plaster Ceiling / In Big Building
ND NF D
LEGEND
D Damaged F Friable G Good
NF Non-Friable ND None Detected
POSITIVE FOR ASBESTOS
Summary of Findings
Our survey did not reveal the presence of Asbestos-Containing Building Material
(ACBM).
Recommendations
While no asbestos-containing materials were found during this survey, it is possible that inaccessible or unidentified materials may be exposed during any renovation and/or demolition activities. Such materials should then be sampled and evaluated.
Please advise should you have any questions about this report or if you need further assistance with this project.
SECTION 3
PHOTOS
SECTION 3: PHOTOS
TWC | CCRC Building ERC Project #02001024.03.01 Page 4
TWC CCRC Building – 4800 North Lamar
Roof Condition
TWC | CCRC Building ERC Project #02001024.03.01 Page 5
Location of Roof Sampling
Roof Sampling
TWC | CCRC Building ERC Project #02001024.03.01 Page 6
Roof Patching
Roof Patching
TWC | CCRC Building ERC Project #02001024.03.01 Page 7
Roofing Material - Caulking
Concrete Deck Sampling
TWC | CCRC Building ERC Project #02001024.03.01 Page 8
Plaster Ceiling Sampling
SECTION 4
DRAWINGS
E n v i r o n m e n t a l
C o n s t r u c t i o n
S e r v i c e s
I n c
SHEET - 1
C C
R
B
U I L
D I N
G
F
I R
S T
F
L O
O
P
L A
N
D
M
O
N
T E
X A
S
W
O R
K F
O R
M
M I S
S I O
N
AB-XX
AB-XX
AB-06
AB-07
AB-08
AB-09
AB-05
AB-04
AB-12
AB-11
AB-10
AutoCAD SHX Text
DRAWING NUMBER:
AutoCAD SHX Text
ERC PROJECT NUMBER:
AutoCAD SHX Text
CONSTRUCTION SERVICES, INC.
AutoCAD SHX Text
ENVIRONMENTAL &
AutoCAD SHX Text
FILE:
AutoCAD SHX Text
SCALE +/-:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
REV BY:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DWG BY:
AutoCAD SHX Text
OF
AutoCAD SHX Text
4800 N LAMAR BLVD., AUSTIN, TX 78756
AutoCAD SHX Text
AUSTIN, TX 78756
AutoCAD SHX Text
2828 FOREST LANE, SUITE 1147
AutoCAD SHX Text
DALLAS, TEXAS 75234
AutoCAD SHX Text
PHONE: 972-243-2177 FAX: 972-243-2179
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NTS
AutoCAD SHX Text
KYL
AutoCAD SHX Text
KA
AutoCAD SHX Text 02001024.03.01
AutoCAD SHX Text
12MAR20
AutoCAD SHX Text
12MAR20
AutoCAD SHX Text 02001024.03.01
AutoCAD SHX Text
INDICATES POSITIVE ASBESTOS SAMPLE LOCATIONS
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
INDICATES NEGATIVE ASBESTOS SAMPLE LOCATIONS
n v i r o n m e n t a l o n s t r u c t i o n
S e r v i c e s
I n c
SHEET - 2
C C
B
U I L
D I N
G
M
P
O
F
P
L A
N
D
E M
O
N
T E
X A
S
W
O R
K F
O R
M
M I S
S I O
N
AB-02
AB-XX
AB-XX
AB-03
AB-01
AutoCAD SHX Text
DRAWING NUMBER:
AutoCAD SHX Text
ERC PROJECT NUMBER:
AutoCAD SHX Text
CONSTRUCTION SERVICES, INC.
AutoCAD SHX Text
ENVIRONMENTAL &
AutoCAD SHX Text
FILE:
AutoCAD SHX Text
SCALE +/-:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
REV BY:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DWG BY:
AutoCAD SHX Text
OF
AutoCAD SHX Text
4800 N LAMAR BLVD., AUSTIN, TX 78756
AutoCAD SHX Text
AUSTIN, TX 78756
AutoCAD SHX Text
2828 FOREST LANE, SUITE 1147
AutoCAD SHX Text
DALLAS, TEXAS 75234
AutoCAD SHX Text
PHONE: 972-243-2177 FAX: 972-243-2179
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NTS
AutoCAD SHX Text
KYL
AutoCAD SHX Text
KA
AutoCAD SHX Text 02001024.03.01
AutoCAD SHX Text
12MAR20
AutoCAD SHX Text
12MAR20
AutoCAD SHX Text 02001024.03.01
AutoCAD SHX Text
INDICATES POSITIVE ASBESTOS SAMPLE LOCATIONS
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
INDICATES NEGATIVE ASBESTOS SAMPLE LOCATIONS
SECTION 5
CITY PERMIT LETTER
March 10, 2020
City of Austin Development Services Department 505 Barton Springs Rd Austin, TX 78704
Re: ERC Project No. 2001024.03.01
Asbestos Survey CCRC Building – Cooler/Freezer Project 4800 N Lamar Blvd Austin, TX 78756
To Whom It May Concern:
On March 2, 2020 a limited building material survey for asbestos-containing material (ACM) was conducted at the above referenced location. The site assessment and material testing addressed all the areas to be impacted by the remodeling and construction work at this location, to comply with Senate bill 509 pertaining to the requirement for asbestos testing prior to the issuance of permits for renovation or demolition by the municipalities. The asbestos survey was conducted by a Texas Department of State Health Services (DSHS) licensed inspector, Mathew Montazari, License No. 602920. Samples were submitted to an approved laboratory (NVLAP) for analysis by Polarized Light Microscopy (PLM). This work was requested and authorized by Mr. Randall Price of Texas Workforce Commission (TWC).
All renovations or demolition activities which could disturb the ACM must be avoided until all asbestos-containing materials have been addressed.
Should you have any questions about this project or this letter, please do not hesitate to call my office at your earliest convenience at 713-290-9444.
Respectfully submitted, ERC
Shelly Horan, AIMP Project Coordinator DSHS Asbestos Management Planner License #205750 Expires: July 29, 2021
APPENDIX A
ERC LICENSES
APPENDIX A: ERC LICENSES
APPENDIX B
LAB RESULTS
EMSL Analytical, Inc.
5950 Fairbanks N. Houston Rd. Houston, TX 77040
Tel/Fax: (713) 686-3635 / (713) 686-3645 http://www.EMSL.com / houstonlab@emsl.com
152001607EMSL Order:
Customer ID: ERC50
Customer PO:
Project ID:
Attention: Phone:Shelly (713) 290-9444
Fax:ERC (713) 290-9441
Received Date:10801 Hammerly Blvd. 03/03/2020 4:15 PM
Analysis Date:Suite 100 03/05/2020 - 03/06/2020
Collected Date:Houston, TX 77043
Project: 02001024.03.01 / 4800 N. Lamar Blvd
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
AB01-Roofing
152001607-0001
None DetectedNon-fibrous (Other)45%Cellulose
Synthetic
Glass
30%
15%
10%
Gray/White/Black
Non-Fibrous
Homogeneous
Roofing Material /
White and Black
AB01-Foam
152001607-0001A
None DetectedNon-fibrous (Other)100%Beige
Non-Fibrous
Homogeneous
Roofing Material /
White and Black
AB02-Roofing
152001607-0002
None DetectedNon-fibrous (Other)45%Cellulose
Synthetic
Glass
30%
15%
10%
Gray/White/Black
Fibrous
Homogeneous
Roofing Material /
White and Black
AB02-Foam
152001607-0002A
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
Roofing Material /
White and Black
AB02-Insulation 1
152001607-0002B
None DetectedNon-fibrous (Other)20%Cellulose80%Beige
Fibrous
Homogeneous
Roofing Material /
White and Black
AB02-Insulation 2
152001607-0002C
None DetectedMica
Non-fibrous (Other)
15%
85%
White
Non-Fibrous
Homogeneous
Roofing Material /
White and Black
AB03-Roofing 1
152001607-0003
None DetectedNon-fibrous (Other)80%Glass20%Black
Fibrous
Homogeneous
Roofing Material /
White and Black
AB03-Roofing 2
152001607-0003A
None DetectedNon-fibrous (Other)80%Cellulose
Glass
10%
10%
Black
Fibrous
Homogeneous
Roofing Material /
White and Black
AB03-Roofing 3
152001607-0003B
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Roofing Material /
White and Black
AB03-Insulation 1
152001607-0003C
None DetectedNon-fibrous (Other)10%Cellulose90%Beige
Fibrous
Homogeneous
Roofing Material /
White and Black
AB03-Foam
152001607-0003D
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Roofing Material /
White and Black
AB03-Felt
152001607-0003E
None DetectedNon-fibrous (Other)30%Cellulose70%Brown
Fibrous
Homogeneous
Roofing Material /
White and Black
AB03-Insulation 2
152001607-0003F
None DetectedCa Carbonate
Matrix
Non-fibrous (Other)
10%
15%
75%
White
Non-Fibrous
Homogeneous
Roofing Material /
White and Black
AB03-Roofing 4
152001607-0003G
None DetectedNon-fibrous (Other)55%Cellulose
Synthetic
30%
15%
Brown/White/Black
Fibrous
Heterogeneous
Roofing Material /
White and Black
AB04
152001607-0004
None DetectedNon-fibrous (Other)100%Gray/Beige
Non-Fibrous
Homogeneous
Roofing Caulking /
Gray - Off White
AB05
152001607-0005
None DetectedNon-fibrous (Other)100%Gray/Beige
Non-Fibrous
Homogeneous
Roofing Caulking /
Gray - Off White
Initial report from: 03/06/2020 12:43:03
Page 1 of 2ASB_PLM_0008_0001 - 1.78 Printed: 3/6/2020 11:43 AM
EMSL Analytical, Inc.
5950 Fairbanks N. Houston Rd. Houston, TX 77040
Tel/Fax: (713) 686-3635 / (713) 686-3645 http://www.EMSL.com / houstonlab@emsl.com
152001607EMSL Order:
Customer ID: ERC50
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
AB06
152001607-0006
None DetectedCa Carbonate
Non-fibrous (Other)
5%
95%
Gray/Beige
Non-Fibrous
Homogeneous
Roofing Caulking /
Gray - Off White
AB07
152001607-0007
None DetectedCa Carbonate
Non-fibrous (Other)
10%
90%
Brown/Gray/Beige
Non-Fibrous
Homogeneous
Concrete Deck Inside
Small Building
AB08
152001607-0008
None DetectedCa Carbonate
Non-fibrous (Other)
10%
90%
Brown/Gray/Beige
Non-Fibrous
Homogeneous
Concrete Deck Inside
Small Building
AB09
152001607-0009
None DetectedCa Carbonate
Non-fibrous (Other)
20%
80%
Gray/Beige
Non-Fibrous
Heterogeneous
Concrete Deck Inside
Small Building
Inseparable paint / coating layer included in analysis
AB10
152001607-0010
None DetectedCa Carbonate
Non-fibrous (Other)
20%
80%
Brown/White/Beige
Non-Fibrous
Heterogeneous
Plaster Ceiling -
Inside Big Building
Inseparable paint / coating layer included in analysis
AB11
152001607-0011
None DetectedCa Carbonate
Non-fibrous (Other)
20%
80%
Brown/White/Beige
Non-Fibrous
Heterogeneous
Plaster Ceiling -
Inside Big Building
Inseparable paint / coating layer included in analysis
AB12
152001607-0012
None DetectedCa Carbonate
Non-fibrous (Other)
20%
80%
White/Beige
Non-Fibrous
Heterogeneous
Plaster Ceiling -
Inside Big Building
Inseparable paint / coating layer included in analysis
Analyst(s)
Jenny Drapela (11)
Wanda Porch (12)
Michelle Leggett, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 "Interim
Method"), but augmented with procedures outlined in the 1993 ("final") version of the method. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . Interpretation and use of test results are the responsibility of the client. All samples received in acceptable condition unless otherwise noted. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. EMSL recommends gravimetric reduction for all non -friable organically bound materials prior to analysis. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. Houston, TX NVLAP Lab Code 102106-0, AZ 0925, CO AL-15355, LA 04126, TX 300159
Initial report from: 03/06/2020 12:43:03
Page 2 of 2ASB_PLM_0008_0001 - 1.78 Printed: 3/6/2020 11:43 AM
APPENDIX C
ASBESTOS GLOSSARY
APPENDIX C: ASBESTOS GLOSSARY
ACBM – Asbestos-Containing Building Materials. Materials containing greater than 1% asbestos, by weight and utilized in building construction. (Measured By PLM.)
ACM – Asbestos-Containing Materials.
AECP – Asbestos Exposure Control Program also referred to as an O & M (Operations and Maintenance) Program.
AHERA – Asbestos Hazard Emergency Response Act signed into law in 1986. The law directs EPA to promulgate regulations for addressing asbestos problems in public and private schools, grades K-12.
Asbestos – Naturally occurring fibrous minerals composed of hydrated silicates, crystalline in structure, occurring as parallel bundles. Two categories: Serpentine (Chrysotile) and Amphibole (Amosite, Anthophylite, Tremolite, Crocidolite, Actinolite).
Friable – Materials that, at present, can be crushed and/or pulverized by hand pressure.
Gypsum Board – A pre-manufactured wall surfacing substrate applied over a wood or metal framing system.
Hazard – A circumstance, mechanism or event that has the potential to create injury.
Hazard Assessment – Analysis and evaluation of physical and exposure factors to determine the need for corrective action.
Homogeneous Area – Areas having materials of the same texture, color, hardness or being of the same property.
Inspection (Survey) – The process of locating and quantifying ACM and assessing its condition.
LEA – Local Education Agency (generally the School Board).
NBS – National Bureau of Standards.
NESHAPS – National Emission Standards for Hazardous Air Pollutants.
NIOSH – National Institute for Occupation Safety and Health.
Non-Friable – Materials that, at present, cannot be crushed and/or pulverized by hand pressure. With appropriate handling techniques, non-friable material will not become friable.
OSHA – Occupational Safety and Health Administration.
APPENDIX C: ASBESTOS GLOSSARY
TWC | CCRC Building ERC Project #02001024.03.01 Page 2
PCM – Phase Contrast Microscopy - Analysis of air samples. NIOSH 7400 method is an optical microscopy fiber counting technique, which does not allow for differentiation between asbestos fibers and other types of fibers.
PEL – Permissible Exposure Limit - Level of exposure to airborne asbestos fibers above which no employee shall be exposed. The PEL is 0.10 fibers per cubic centimeter expressed as an 8-hour time-weighted average (measured by PCM). PEL's are enforced by the Occupational Safety and Health Administration (OSHA).
PLM – Polarized Light Microscopy - Analysis of bulk material samples.
Positive Stop Method – A method used by a certified laboratory. If one material is analyzed to contain asbestos content none of the other samples of that same homogenous area are analyzed.
Renovation – Altering in any way one or more facility components (except demolition).
TEM – Transmission Electron Microscopy - A high-resolution electron microscopy technique that allows for positive identification and classification of asbestos fibers. The counting technique includes only asbestos fibers.
Houston 10801 Hammerly Blvd, Ste 100
Houston, TX 77043 T: 713-290-9444 | F: 713-290-
Dallas/Fort Worth 2828 Forest Ln, Ste 1147
Dallas, TX 75234 T: 972-243-2177 | F: 972-243-
Austin 3300 Bee Cave Rd, Ste 143
Austin, TX 78746 T: 877-290-9444
ERC Electronic Back Report Cover
| 02001024.03.01 - TEXAS WORKFORCE COMMISION - 1-2.pdf |
| Sheets and Views |
| Model |
| 02001024.03.01 - TEXAS WORKFORCE COMMISION - 2-2.pdf |
| Sheets and Views |
| Model |
File details come from the government source that posted it. Updated .