Summary: Texas State Capitol North Entrance Door Operator Replacement Project Documents
This is a comprehensive project plan document set for the Texas State Capitol Accessible Entrance Door Operators project located at 1100 Congress Avenue in Austin, Texas, prepared by architect Jacqui Dodson AIA Architecture & Interior Design, Inc., with MEP engineering by B2AEP, LLC. The project involves the replacement of existing hydraulic swing door operators with new Record USA C127X center pivot automatic door operators at the north entrance, including demolition of existing equipment, installation of new operators, modification of existing pivot arms, and associated electrical, plumbing, and structural work. The scope includes removal of existing hydraulic piping and equipment, installation of new bronze thresholds, pressure plates and mats, modification of mounting systems to accommodate new pivot points, installation of new control panels and wiring, and coordination with structural elements including concrete troughs and drain systems. The project incorporates accessibility requirements per 2012 Texas Accessibility Standards (TAS) and includes detailed specifications for demolition procedures, new construction methods, fire protection system compliance, and coordination with existing building systems and adjacent trades.
The architectural and engineering documents establish comprehensive construction standards requiring contractor compliance with all applicable codes including the International Building Code, National Fire Protection Association standards, and local jurisdictional requirements. The contractor bears responsibility for field verification of all existing conditions, submission of shop drawings and product data for review, coordination with all building trades, protection of existing work, and adherence to manufacturer installation instructions. Key requirements include submission of submittals within specified timeframes with penalties for deficient or repeated submissions, maintenance of security and temporary facilities, compliance with Texas accessibility standards for door clearances and mounting heights, coordination with the State Preservation Board regarding historic treatment of brick and stone areas, and provision of final cleaning and as-built documentation. The project documents reference separate electrical, fire protection, and plumbing systems drawings that establish additional technical requirements, while emphasizing that the contractor must conduct a thorough pre-bid review of all documents and coordinate completely with existing building operations to minimize disruption during construction.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. THE CONTRACTOR REPRESENTS THAT HE HAS THOROUGHLY REVIEWED THE DRAWINGS, SPECIFICATIONS AND CONTRACT DOCUMENTS AND THAT THEY ARE SUITABLE FOR SUBMITTING A VALID BID. CONTRACTOR SHALL SUBMIT A WRITTEN DESCRIPTION OF ALL DEFICIENCIES AND AMBIGUITIES IN THE CONTRACT DOCUMENTS TO THE OWNER WITHIN 7 DAYS OF SIGNING THE CONTRACT. CHANGE ORDERS FOR DESIGN DEFICIENCIES OR AMBIGUITIES NOT
INCLUDED IN CONTRACTOR'S DESCRIPTION WILL NOT BE ALLOWED.
2. THE CONTRACTOR ACKNOWLEDGES ITS RESPONSIBILITY TO SUBMIT CORRECT SHOP DRAWINGS AND OTHER REQUIRED SUBMITTALS. INCORRECT SUBMITTALS WILL BE RETURNED TO THE CONTRACTOR WITHIN 3 CALENDAR DAYS NOTING THE DEFICIENCIES. IF THE DEFICIENCIES ARE NOT CORRECTED IN THE NEXT SUBMITTAL, ANY TIME SPENT ON RE-REVIEWS WILL BE CHARGED TO THE CONTRACTOR AND DEDUCTED FROM ITS NEXT PROGRESS PAYMENT.
3. THE CONTRACTOR ACKNOWLEDGES ITS RESPONSIBILITY TO BE FAMILIAR WITH THE CONTRACT DOCUMENTS.
REQUESTS FOR INFORMATION (RFIS) WILL BE RESPONDED TO THE CONTRACTOR WITHIN 3 CALENDAR DAYS OF RECEIPT. TIME SPENT REVIEWING RFIS IN WHICH THE INFORMATION REQUESTED IS CLEARLY INCLUDED IN THE DRAWINGS OR SPECIFICATIONS WILL BE CHARGED TO THE CONTRACTOR AND DEDUCTED FROM ITS NEXT PROGRESS
PAYMENT.
4. ALL WORK SHALL CONFORM TO THE CONTRACT DOCUMENTS WHICH INCLUDE THE OWNER/CONTRACTOR AGREEMENT, THE DRAWINGS AND ALL ADDENDA AND MODIFICATIONS ISSUED BY THE ARCHITECT.
5. THE CONTRACTOR SHALL REVIEW ALL DOCUMENTS AND VERIFY ALL DIMENSIONS AND FIELD CONDITIONS AND SHALL CONFIRM THAT WORK CAN BE CONSTRUCTED AS SHOWN. ANY CONFLICTS OR CLARIFICATIONS, INCLUDING THOSE BETWEEN THE MEP AND ARCHITECTURAL DRAWINGS, SHALL BE IMMEDIATELY REPORTED TO THE ARCHITECT FOR
CLARIFICATION PRIOR TO THE PERFORMANCE OF ANY WORK IN QUESTION.
6. DIMENSIONS ARE TO FACE OF MATERIAL UNLESS NOTED OTHERWISE. WRITTEN DIMENSIONS GOVERN, DO NOT SCALE
DRAWINGS. NOTIFY THE ARCHITECT FOR REQUIRED DIMENSIONS IF NOT NOTED.
7. SUBSTITUTIONS, REVISIONS, OR CHANGES MUST BE SUBMITTED TO ARCHITECT AND CONSTRUCTION MGR. FOR REVIEW
PRIOR TO PURCHASE, FABRICATION OR INSTALLATION.
8. CONTRACTOR TO CONFIRM WITHIN SEVEN (7) DAYS OF ISSUE OF CONTRACT DOCUMENTS ANY LONG LEAD ITEMS, WHICH MAY IMPACT COMPLIANCE WITH THE PROJECT SCHEDULE.
9. "ALIGN" SHALL MEAN TO ACCURATELY LOCATE FINISHED FACES IN THE SAME PLANE.
10. "TYPICAL" OR "TYP" SHALL MEAN THAT THE CONDITION IS REPRESENTATIVE FOR SIMILAR CONDITIONS THROUGHOUT, UNLESS OTHERWISE NOTED.
11. "SIMILAR" MEANS COMPARABLE CHARACTERISTICS FOR THE CONDITIONS NOTED. VERIFY DIMENSIONS AND
ORIENTATION ON DRAWINGS AND ELEVATIONS.
12. ALL WORK NOTED "BY OTHERS" OR "NIC" SHALL BE PROVIDED BY TENANT OR UNDER SEPARATE CONTRACT. INCLUDE SCHEDULE REQUIREMENTS FOR THIS "OTHER" WORK IN CONSTRUCTION PROGRESS SCHEDULE AND COORDINATE AS REQUIRED TO ASSURE ORDERLY SEQUENCE OF INSTALLATION. "OFCI" MEANS ITEMS FURNISHED BY THE OWNER, AND INSTALLED BY THE CONTRACTOR. CONTRACTOR SHOULD INCLUDE INSTALLATION COSTS IN THE BID.
13. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY. WHAT IS SHOWN OR REFERRED TO ON ANY SHALL BE PROVIDED
AS THOUGH SHOWN ON ALL. DO NOT DISASSEMBLE SETS OF DRAWINGS.
14. ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE APPLIED, INSTALLED CONNECTED, ERECTED, CLEANED AND CONDITIONED PER MANUFACTURER'S INSTRUCTIONS. IN CASE OF DIFFERENCE BETWEEN THE MANUFACTURER'S INSTRUCTIONS AND THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT
BEFORE PROCEEDING.
15. THE CONTRACTOR SHALL OBTAIN ALL PERMITS AND INSPECTIONS AND COMPLY WITH ALL CODES, LAWS, ORDINANCES, RULES, AND REGULATIONS OF ALL PUBLIC AUTHORITIES (FEDERAL, STATE, OR LOCAL) GOVERNING THE
WORK. IN CASE OF CONFLICT, THE MOST STRINGENT SHALL APPLY.
16. THE CONTRACTOR, IN COORDINATION WITH THE OWNER, SHALL COORDINATE CONSTRUCTION PERSONNEL PARKING LOCATION AND REQUIREMENTS. DRIVEWAYS AND ENTRANCES SERVING THE PREMISES ARE TO BE CLEAR AND AVAILABLE FOR USE AT ALL TIMES. SCHEDULE DELIVERIES WITH BUILDING OWNER OR CONSTRUCTION MANAGER.
17. WORK AREAS ARE TO REMAIN SECURE AND LOCKABLE DURING CONSTRUCTION. CONTRACTOR SHALL COORDINATE
WITH OWNER TO ENSURE SECURITY.
18. DURING HANDLING AND INSTALLATION OF WORK AT PROJECT, CLEAN AND PROTECT WORK IN PROGRESS AND ADJOINING WORK CONTINUALLY. APPLY SUITABLE PROTECTIVE COVERING ON NEWLY INSTALLED WORK WHERE REASONABLY REQUIRED TO ENSURE FREEDOM FROM DAMAGE OR DETERIORATION AT TIME OF SUBSTANTIAL
COMPLETION.
19. THE CONTRACTOR SHALL ENSURE THAT CAUTION IS TAKEN TO PROTECT THE BUILDING, ELEVATOR, AND ADJACENT FINISHED AREAS FROM BEING DAMAGED. ANY DAMAGE SHALL BE REPAIRED AT THE CONTRACTOR'S COST.
20. CONTRACTOR SHALL COORDINATE WITH THE OWNER THE SCHEDULE ALL POWER OUTAGES.
21. CONTRACTOR SHALL MAINTAIN FOR THE DURATION OF THE WORK ALL EXISTING EXIT LIGHTING, AND FIRE PROTECTIVE DEVICES AND ALARMS IN CONFORMANCE WITH ALL APPLICABLE CODES AND ORDINANCES. CONTRACTOR IS RESPONSIBLE FOR INSTALLING ALL NECESSARY FIRE ALARM DEVICES, TO COMPLY WITH LIFE SAFETY CODE AND TEXAS
ACCESSIBILITY REQUIREMENTS.
22.FIRE PROTECTION SYSTEM DESIGN IS THE RESPONSIBILITY OF THE CONTRACTOR'S FIRE PROTECTION SYSTEM CONTRACTOR. THE FIRE PROTECTION SYSTEM SHALL BE DESIGNED BY A TEXAS PROFESSIONAL ENGINEER WHO IS
LICENSED FOR THIS TYPE OF SYSTEM.
23. CONTRACTOR TO PROVIDE SUFFICIENT TEMPORARY LIGHTING TO ENSURE PROPER WORKMANSHIP EVERYWHERE; BY
COMBINED USE OF DAYLIGHT, GENERAL LIGHTING, AND PORTABLE PLUG-IN TASK.
24. CONTRACTOR TO COORDINATE THE USE OF BUILDING TOILET FACILITIES WITH THE BUILDING OWNER'S REPRESENTATIVE.
25. CONTRACTOR SHALL OPERATE TEMPORARY SERVICES AND FACILITIES IN A SAFE AND EFFICIENT MANNER. DO NOT OVERLOAD TEMPORARY SERVICES OR FACILITIES, AND DO NOT PERMIT THEM TO INTERFERE WITH THE PROGRESS OF
THE WORK.
26. LAYOUT OF EQUIPMENT, ACCESSORIES, AND PIPING SYSTEMS ARE DIAGRAMMATIC, EXCEPT AS SPECIFICALLY DIMENSIONED. COORDINATE THE WORK WITH THE VARIOUS MECHANICAL AND ELECTRICAL TRADES SO AS TO AVOID INTERFERENCE, AND TO SECURE MAXIMUM HEADROOM, CLEAR ACCESS TO PIPES AND DUCTS AND MAXIMUM USABLE
AREA.
27. CONTRACTOR SHALL NOTIFY ARCHITECT AND CONSTRUCTION MANAGER IMMEDIATELY OF ALL UTILITIES DETERMINED IN THE COURSE OF CONSTRUCTION AS BEING NECESSARY TO BE REMOVED WHICH HAVE NOT OTHERWISE BEEN NOTED FOR REMOVAL IN THE CONSTRUCTION DOCUMENTS. CONTRACTOR SHALL REMOVE SUCH UTILITIES ONLY AFTER CONSULTATIONS WITH ARCHITECT AND LANDLORD. WHETHER PREDETERMINED IN THE CONSTRUCTION DOCUMENTS OR DETERMINED LATER IN FIELD, DISCONNECT, CUT BACK TO SOURCE, AND CAP ALL UTILITY SERVICES REMOVED.
SEAL ALL PENETRATIONS CREATED BY REMOVAL OF UTILITIES TO MATCH ADJACENT CONSTRUCTION AND FINISHES.
28. ELECTRICAL PANELS FIRE EXTINGUISHER AND OTHER ITEMS INSTALLED IN WALLS SHALL BE BACKED WITH DRYWALL TO MAINTAIN REQUIRED FIRE RATINGS. CONTRACTOR SHALL COORDINATE AND PROVIDE METAL BACKING PLATES OR SOLID WOOD BLOCKING (FIRE TREATED) IN PARTITIONS FOR ALL MILLWORK AND WALL ATTACHED ITEMS.
29. REQUIRE INSTALLER OF EACH MAJOR UNIT OF WORK TO INSPECT SUBSTRATE TO RECEIVE WORK, AND CONDITIONS UNDER WHICH WORK WILL BE PERFORMED, AND TO REPORT UNSATISFACTORY CONDITIONS. DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED IN A MANNER ACCEPTABLE TO INSTALLER.
30. WHERE INSTALLATIONS INCLUDE MANUFACTURED PRODUCTS, COMPLY WITH MANUFACTURER'S APPLICABLE INSTRUCTIONS AND RECOMMENDATIONS FOR INSTALLATION, TO THE EXTENT THAT THESE ARE MORE EXPLICIT OR MORE
STRINGENT THAN REQUIREMENTS INDICATED IN CONTRACT DOCUMENTS.
31. PROVIDE ATTACHMENT AND CONNECTION DEVICES AND METHODS FOR SECURING WORK PROPERLY AS IT IS INSTALLED; TRUE TO LINE AND LEVEL, AND WITHIN RECOGNIZED INDUSTRY TOLERANCES IF NOT OTHERWISE INDICATED.
ALLOW FOR EXPANSION AND BUILDING MOVEMENTS. PROVIDE UNIFORM JOINT WIDTHS IN EXPOSED WORK, ORGANIZED FOR BEST POSSIBLE VISUAL EFFECT. REFER QUESTIONABLE VISUAL EFFECT CHOICES TO ARCHITECT AND
CONSTR. MGR. FOR FINAL DECISION.
32. CONTRACTOR SHALL KEEP A MARKED UP SET OF CONSTRUCTION DOCUMENTS AS A RECORD COPY OF THE PROJECT.
RECORD DOCUMENTS SHALL BE DELIVERED TO THE OWNER AT PROJECT COMPLETION.
33. ALL ROOM NUMBERS AND AREA NUMBERS ARE SHOWN FOR DRAWING COORDINATION ONLY UNLESS DIRECTED
OTHERWISE BY OWNER.
34. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR SPECIAL SYSTEMS AND MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS (INCLUDING FIRE PROTECTION SYSTEMS) WHEN REQUIRED BY MEP DOCUMENTS.
35. CONTRACTOR SHALL SUBMIT PRODUCT DATA FOR REVIEW BY ARCHITECT AND MEP ENGINEER FOR, AT MINIMUM, THE
FOLLOWING ITEMS: DOORS, FRAMES, HARDWARE.
TE
XA
S
ST
AT
E
C
AP
IT
O
L
AC
C
ES
SI
BL
E
EN
TR
AN
C E
D O
O R
O
PE
R
AT
O R
S
C
O N
G R
ES
S
AV
E
AU
ST
IN
T
X
BYNO. DATE DESCRIPTION
REVISIONS
DATE:
CHECKED:
DRAWN:
PHASE:
JOB NO.:
JGD
08/30/24
2024-01
JGD
CD
These designs / drawings are the sole property of the Architect, Jacqui Dodson AIA Architecture & Interior Design, Inc. These documents may not be reproduced in any form, by any method, for any purpose without previous written consent from the Architect.
JA
CQ
UE
LINEG.DODSON
08/30/24
2105 ARPDALE STREET
A U S T I N, T X 7 8 7 0 4 5 1 2 . 6 9 9 . 9 7 0 8
PLAN
NORTH
O.H.
T.B.D.
SECTION
METAL
PLYWOOD
U.N.O.
O.C. ON CENTER
SHEET
DIAMETER
REFERENCE
SHT.
REF.
DIA.
DWG. DRAWING
ADJUSTABLE
DETAIL
SECT.
ADJ.
DTL.
N.I.C.
AFF
MTL.
CL
ADA
TAS
TDLR
REQUIREDREQ'D.
PLAM.
PLYWD.
X
X/
XX
.X
ROOM NAME
X/XX.X
GENERAL NOTES
A0.0 COVER SHEET
A0.1 ACCESSIBILITY INFO
A0.2 SPECIFICATION SHEET
A1.0 DEMOLITION ENLARGED PLANS
A1.1 NEW CONSTRUCITON ENLARGED PLANS,
ELEVATIONS & DETAILS
A1.2 SECTIONS & DETAILS
INDEX OF DRAWINGS
OPPOSITE HAND
TO BE DETERMINED
AMERICANS WITH DISABILITIES ACT
TEXAS ACCESSIBILITY STANDARDS
TEXAS DEPARTMENT OF LICENSING
PLASTIC LAMINATE
UNLESS NOTED OTHERWISE
CENTER LINE
ABOVE FINISHED FLOOR
NOT IN CONTRACT
& REGULATION
LEGEND PROJECT TEAM CONTACTS
DRAWING REVISION
ELEVATION
SECTION
A0.0
INFORMATION
MIN.
MAX. MAXIMUM
MINIMUM
TEXAS STATE CAPITOL BUILDING
GENERAL
ABBREVIATIONS
ROOM NAME
ENLARGED PLAN/DETAIL
XX/XX.XX
A/1
HW.1
DOOR TYPE / FRAME TYPE
HARDWARE TYPE
EXISTING DOOR TO REMAINE
E1 EXISTING DOOR TO BE RELOCATED
A PARTITION TYPE
1 KEYED NOTE
EXISTING WALL TO REMAIN
EXISTING CONSTRUCTION TO BE REMOVED
NEW PARTITION
NEW PARTITION WITH FIRE RATING (REF WALL TYPE)
ARCHITECTURAL
DUPLEX OUTLET
VOICE/DATA
RECESSED LIGHT FIXTURE
QUAD OUTLET
S SECURITY CAMERA
EXIT SIGN- CEILING MOUNT
EXIT SIGN - WALL MOUNT
2'X4' PARABOLIC LIGHT FIXTURE
HVAC SUPPLY (CLG.)
HVAC RETURN (CLG.)
SWITCH
N = NEW
SPRINKLER HEAD
FIRE EXTINGUISHER / BRACKET MOUNT
2'X4' FLUORESCENT FIXTURE
S SPEAKER (CEILING)
ROOM NUMBER
FEC
NORTH ENTRANCE DOOR OPERATOR REPLACEMENT
*DATA AND PHONE SHOWN FOR DEVICE LOCATIONS ONLY
FOR GENERAL CONTRACTOR'S SCOPE. COORDINATE EXACT
DEVICE WITH TELECOM VENDOR.
EXST. EXISTING
E.T.R. EXISTING TO REMAIN
E = EXISTING
R = RELOCATED
PROPERTY OWNER
ARCHITECT
JDAI
2105 ARPDALE STREET
AUSTIN TX 78704
CONTACT: JACQUI DODSON, 512/699.9708
ELECTRICAL | PLUMBING
MEP ENGINEER
B2AEP
3510 EAGLE WAY
ROUND ROCK, TX 78681
CONTACT: CHAD BLACK 512-925-7418
CHADBLACK@B2AEP.COM
AREA OF WORK
AREA OF WORK
Push Side
Push Side y = 48in minimum if door y = 48in minimum if door has both a latch and closer door has a closer.
y = 54in minimum if
Latch Side Approaches - Swinging Doors
Y m in
NOTE:
Pull Side
NOTE:
has a closer
Hinge Slide Approaches - Doors
24"min
X 24min
Y
"m in x = 36in minimum if y = 60in;
x = 42in minimum if y = 54in
NOTE:
Pull Side
Pull Side
" m in
Front Approaches - Swing Doors y
Y
X 22"min
NOTE:
"m in
"m in
18"min, 12" if door has both
Push Side closer and latch
" M
IN
IM
UM
32" CLEAR
" M
IN
Doors in a Series
1 1/4"
TO 1 1/2" 1 1/2"
HANDRAIL
C
LE
A R
FL
O
O R
TOILET
48" MIN.
" M
A X
" M
A X.
13.5" MIN
" M
A X
6" MAX.
9" M
IN
17"-19"
8" MIN.
" M
IN
30" MIN.
(F
RO
N T)
"M
A X
(S
ID
E)
8"
" M
IN
8" MAX
Light switch Thermostats, Etc.
Convenience Outlets Data, Tel., Etc.
control
18"
SHOWER STALL
SHOWER SEAT DETAIL
48" fu ll d ep th o f s ta ll
15-16"
1 1/2" max 1 1/
2" m ax clear floor space se at w al l back control area area
-1
5"
"M
A X
" M
IN
-3
6"
48" MIN.
19" MAX.
17" MIN.
" M
IN
" M
A X
" M
IN
" M
A X
10" MAX 10" MAX
4" MAX.
" M
IN
" M
IN
ANY AMOUNT
" M
A X.
CLEAR WIDTH
9" M
IN
" M
IN
" M
IN
" M
A X.
" M
A X.
T O
R
EF
LE
C
TIV
E
SU
RF
A C
E
6" MAX.
17" MIN.
8" MIN.
TO
LO
W
ES
T O
PE
RA
BL
E
FU
N
C
TIO
N
Measured to highest point of control
5'-0" MIN
16-18"
SP
A
C E
PAPER
3' -0
" M
IN
36"
MIN
12"
MIN
CL OF FLUSH VALVE
TOP OF RIM AT FRONT OF URINAL
3' -0
X
WHEN X>2'-0"
C
LR
C
LR
4'-0"
CLR
13.5" MIN
4' -8
4' -1
1"
W /W
A
LL
M
TD
. W .C
W /F
LO
O
R M
TD
. W
.C
4' -4
" M
IN
. 1' -0
M A
X
5'-0" MIN
4' -4
" M
IN
1' -0
M A
X
16"-18"
C L
C L
4' -8
4' -1
1"
W /W
A
LL
M
TD
. W .C
W /F
LO
O
R M
TD
. W
.C
4"
MAX
2'-8" MIN
CLR DOOR OPENING
FAUCET W/SINGLE
LEVER OR WRISTBLADE
HANDLE
CLR
FLOOR
SPACE
CENTERED
ON
SINK
CL
CLCL
1' -5
"-1 '-7
T.
O
. S
EA
T
36" clear floor space
" M
IN
60" MIN
16" TO 18"
4' -8
" M
IN
5'-0" MIN
CL 3'-6"
MIN
SP
O
UT
H
EI
G
HT
48"
M
IN
C
LR
MIN CLR
1'
-3
1' -3
" C L
C
LR
C
LR
30X60 SHOWER STALL
control control area area
"M
A X
" M
IN
-3 6"
Clearance at Recessed Doors
WC
"m in
Push Side
15" MAX
CL
SEAT
CL
BARWCBAR 24"
MIN
" m in
18"min, X>8
" m in
X>8
" m in
X>8
12" if door has both closer and latch
3'-0"
X>
X>
5'-0"
3'-0" 2'
-0
3' -0
5'-0"
CLEARANCE AT ALCOVES
T-SHAPED TURN AROUND
1'-0"
1'-0"
" M
IN
CL
ALT DOOR
LOCN
20" MAX >20-25" MAX
" M
A X
" M
A X
" M
A X
10"-24" MAX
" M
A X
" M
IN
IM
UM
32" CLEAR
NON CIRCULAR GRABBARS
SPACING OF GRABBARS
CHECK OUT COUNTERS
NO OBJECTS WITHIN
THE CLEAR FLOOR
SPACE
T .O
. B A
R
"M
IN
6"
M A
X.
TOE CLEARANCE AT STALL
TOE CLEARANCEL
TOE CLEARANCEL
42" MIN12" MAX
" T
.O . B
A R
" M
IN7-9"
TO CL OF ROLL
CL
54" MIN. CL
" M
A X
1/
2"
TP MUST BE
RECESSED IN
THIS AREA
TE
XA
S
ST
AT
E
C
AP
IT
O
L
AC
C
ES
SI
BL
E
EN
TR
AN
C E
D O
O R
O
PE
R
AT
O R
S
C
O N
G R
ES
S
AV
E
AU
ST
IN
T
X
BYNO. DATE DESCRIPTION
REVISIONS
These designs / drawings are the sole property of the Architect, Jacqui Dodson AIA Architecture & Interior Design, Inc. These documents may not be reproduced in any form, by any method, for any purpose without previous written consent from the Architect.
JA
CQ
UE
LINEG.DODSON
08/30/24
2105 ARPDALE STREET
A U S T I N, T X 7 8 7 0 4 5 1 2 . 6 9 9 . 9 7 0 8
PLAN
NORTH
DRINKING FOUNTAINS CLEARANCES AT DOORSSHOWER STALLS TOILET STALLS
TOILET ELEVATIONS
URINALS
END OF ROW STALL
REACH RANGES
DOOR SIGN & MOUNTING HEIGHTS
LAVATORIES
PROTRUDING OBJECTS
MOUNTING HEIGHTS
STALL PLANS
STANDARD STALL
CLR FLOOR SPACE AT WATER CLOSET
HAND RAIL
NOTES
1. THE INFORMATION ON THIS SHEET IS INTENDED TO BE A REFERENCE FOR REQUIREMENTS SET FORTH
IN THE 2012 TEXAS ACCESSIBILITY STANDARDS ISSUED BY THE TEXAS DEPARTMENT OF LICENSING
AND REGULATION. THIS SHEET DOES NOT ADDRESS COMPLIANCE WITH OTHER CODES OR
STANDARDS.
2. IF CONTRACTOR FINDS CONFLICT WITH THIS SHEET AND THE DESIGN INTENT OF THE WORK, NOTIFY
ARCHITECT FOR RESOLUTION.
3. DO NOT SCALE THIS SHEET.
4. DIMENSIONS ARE TO FINISHED FACE OF WALLS.
5. NOT ALL DRAWINGS ON THIS SHEET ARE APPLICABLE TO THIS PROJECT. USE THIS SHEET FOR
REFERENCE ONLY ON ITEMS WITHIN THE SCOPE OF THE WORK.
TOE & KNEE CLEARANCES
MANEUVERING CLEARANCES
CLEARANCES
ARE
MINIMUMS
COUNTERS
TACTILE CHARACTERS HEIGHT TACTILE CHARACTERS LOCATION
A0.1
INFO. SHEET
ACCESSIBILITY
THE OWNER AND THE CONTRACTOR ACKNOWLEDGE THAT ITEMS MOUNTED BY THE OWNER OR
CONTRACTOR THAT ARE NOT SHOWN ON THE PLANS BUT PROVIDED BY THE CONTRACTOR OR
OWNER (SUCH AS SOAP DISPENSERS, PAPER TOWEL DISPENSERS, SANITIZING GEL DISPENSERS, FIRST AID KITS AND FIRE EXTINGUISHERS) ARE ALSO SUBJECT TO TAS REQUIREMENTS AND SHALL
COMPLY WITH TAS 307.2 PROTRUSION LIMITS AND TAS 308.2.1 UNOBSTRUCTED FORWARD REACH.
NOTE REGARDING MOUNTING HEIGHTS AND PROTRUDING OBJECTS
FORCE REQUIRED TO OPEN DOORS SHALL NOT EXCEED 5 POUND FORCE
WASTE / CLEAN UP NOTES
1. Comply with safety standards and governing regulations for cleaning operations. Where extra materials of value remaining after completion of associated Work have become Owner's property, dispose of these to Owner's best advantage.
2. Contractor to provide final cleaning of the Work, at time indicated, consisting of cleaning each surface or unit or Work to normal "clean" conditions. Cleaning shall include but is not limited to:
Remove labels which are not required as permanent labels.
Wipe surfaces of mechanical and electrical equipment clean; remove excess lubrication and other substances.
Where projects have included exterior work or staging:
Clean project site (yard and grounds) of litter and foreign substances.
Sweep paved areas to a broom-clean condition: remove stains, petro-chemical spills and other foreign deposits.
Rake grounds that are neither planted nor paved to a smooth even textured surface.
3. The Contractor shall comply with all applicable provisions of local, state, and federal laws regarding the discharge of wastes into sewers and waterways.
4. All items indicated to be removed which will be of value after removal shall be removed with care as though the item is to be reinstalled in the remodeling Work. Such items not indicated to be reinstalled shall be turned over to the Owner, unless the Owner declines to accept the item whereupon the Contractor shall promptly remove from the site. Where indicated on drawings to be removed and reinstalled, carefully remove indicated items clean and store for reinstallation as specified.
5. Remove debris, rubbish and other materials resulting from demolition operations from building site. Transport and legally dispose of materials off site.
DEMOLITION NOTES
1. Protect from damage existing finish Work that is to remain in place and becomes exposed during demolition operations.
2. Repair demolition performed in excess of that required. Return structures and surfaces to remain to condition existing prior to commencement of selective demolition Work. Repair adjacent construction or surfaces soiled or damaged by selective demolition Work, including but not limited to walls, flooring and ceilings.
3. When demolition is indicated of an assembly, all components of the assembly shall be removed whether hidden within the new Work. Portions of walls above concealed ceilings shall be removed if the wall is indicated to be removed.
4. Where existing ceiling is indicated to be removed, all components of that assembly shall be removed. Ductwork shall remain in place.
5. Before demolition may begin, Contractor shall coordinate with the owner the termination and relocation of all electrical systems, switchgear, equipment, etc.
6. Remove electrical fixtures, wiring, and equipment as required.
Remove conduit and wires servicing electrical equipment to distribution panels unless otherwise approved. Remove abandoned data cabling.
7. Existing utilities to remain are to be kept in service throughout course of the Work. Certain service elements to remain may be located in and through demolished assemblies. The contractor as required shall remove, replace, and reroute these services.
8. If unanticipated mechanical, electrical or structural which conflict with intended function or design are encountered, investigate and measure both nature and extent of the conflict. Submit report to Owner's Representative.
9. Remove telephone fixtures, wiring and equipment as required.
Conduit may remain.
10. Upon completion of demolition Work, remove tools equipment and demolished materials from the site. Remove protection and leave interior areas broom clean.
SECTION 8740
BLASI C127 X CENTER PIVOT IN-GROUND OPERATED SWING DOOR OPERATOR
PART 1-GENERAL
1.01 DESCRIPTION
A. THIS SECTION DESCRIBES THE REQUIREMENTS FOR INSTALLATION OF THE BLASI C127 X
CENTER PIVOT (OR EQUAL) SWING DOOR OPERATOR IN LEFT OR RIGHT HAND
EXECUTION.
1. LOW ENERGY SWING DOOR OPERATORS MEETING ANSI A156.19.
2. HIGH SPEED, HEAVY DUTY SWING DOOR OPERATORS MEETING ANSI A156.10 AND
THAT UTILIZE SAFETY SYSTEMS AND RAILS AS REQUIRED BY THIS ANSI STANDARD.
B. RELATED SECTIONS
1. ELECTRICAL CONNECTIONS (HIGH AND LOW VOLT) AS SPECIFIED IN ELECTRICAL
SPECIFICATIONS
1.02 SUBMITTALS
A. PRODUCT DATA: FURNISH BLASI C127 X CENTER PIVOT (OR EQUAL) PRODUCT DATA
AND STANDARD DETAILS INCLUDING FABRICATION, FINISHING, HARDWARE, OPERATOR,
ACCESSORIES, AND OTHER COMPONENTS OF THE WORK. INCLUDE ROUGH-IN DIAGRAMS,
WIRING DIAGRAMS, AND MAINTENANCE INSTRUCTIONS.
B. SHOP DRAWINGS: FURNISH SHOP DRAWINGS FOR FABRICATION AND INSTALLATION.
SHOW ANCHORS, CEMENT CASINGS, HARDWARE, AND OTHER COMPONENTS NOT SHOWN
IN DOOR OPERATOR'S INSTRUCTIONS.
C. TEMPLATES AND DIAGRAMS: FURNISH TEMPLATES, DIAGRAMS, BLOCK-OUT DIMENSIONS,
AND OTHER DATA TO FABRICATORS AND INSTALLERS OF RELATED WORK FOR
COORDINATION OF OPERATORS WITH DOORS, FRAMES, HARDWARE, ELECTRICAL, AND
OTHER WORK.
1.03 QUALITY ASSURANCE
MANUFACTURER'S QUALIFICATIONS: MANUFACTURER MUST HAVE A MINIMUM OF FIVE (5)
YEARS EXPERIENCE IN THE FABRICATION OF IN-FLOOR AUTOMATIC DRIVE SYSTEMS SIMILAR
TO THOSE SPECIFIED. DOOR PACKAGES SHALL BE WARRANTED AGAINST DEFECT IN
MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM THE DATE OF
INSTALLATION. INSTALLATION SHALL BE APPROVED BY AN AAADM CERTIFIED INSPECTOR.
A. INSTALLER'S QUALIFICATIONS: C127 X (OR EQUAL) SWING DOOR OPERATOR SHALL BE
OBTAINED AND INSTALLED SOLELY THROUGH AND BY AN AUTHORIZED TRAINED AND
FACTORY CERTIFIED AUTOMATIC DOOR PROVIDER. CONSULT MANUFACTURER (BLASI,
RECORD) FOR THE CURRENT LISTING.
PART 2-PRODUCTS
2.01 APPROVED MANUFACTURER
A. BLASI GMBH
CARL-BENZ-STR. 5 -15
77972 MAHLBERG / GERMANY
2.02 IN-GROUND SWING DOOR OPERATOR
A. DRIVE: TOTALLY NOISELESS DRIVE WITH HIGH PERFORMANCE GEAR FOR 90 DEGREE UP
TO 120 DEGREE OPENINGS. FULLY POWERED AUTOMATIC DRIVE WITHOUT HYDRAULICS
OR PNEUMATIC AND OPERATED WITH LOW VOLTAGE DC CHOPPED MOTOR AND SELF
CLOSING SPRING SYSTEM THAT ALLOWS THE DOOR TO CLOSE EVEN IN THE SITUATION
OF LOSS OF POWER.
1. DC LOW VOLTAGE MOTOR WITH HIGH CAPACITY SPECIAL ECCENTRIC GEARING
2. GEAR RATIO 59:1 FOR UP TO 600 KG HEAVY DOOR LEAVES. AUTOMATIC, PUSHES TO
START (POWER ASSIST) OPERATION OR PUSH-BUTTON ACTIVATION ARE POSSIBLE
FUNCTIONS THAT CAN BE OFFERED.
3. FLOOR BOX MANUFACTURED FROM DIE-CASTING ALUMINUM METAL.
4. FULLY TESTED IP RATING 67, 68 AND 69 WITH CERTIFICATE
5. ALL IN ONE DESIGN - NO EXTERNAL CABINET OR SWITCH BOX REQUIRED
6. EXTERNAL OPENING CYCLE ADJUSTMENT
7. DETACHABLE MOUNTING BRACKETS
8. INTERFACE FOR BLUETOOTH CONNECTION FOR SERVICE TABLET ACCESS
9. INCLUDING SUPER STRONG PIVOT ARM ASSEMBLY IN VARIOUS DESIGNS
10.COVER PLATE MADE OF DIE-CASTING ALUMINUM METAL.
11.ELECTRONIC CONTROL WITH FOUR (4) FUNCTIONS.
a) OFF/LOCKED
b) AUTOMATIC
c) ONE WAY
d) HOLD OPEN
12.SPEED AND OPENING TIME FULLY ADJUSTABLE.
13.AUTO-ADJUST POWER SUPPLY UNIT FOR 110V-230V AC, SINGLE PHASE 10 AMPS;
POWER CONSUMPTION 200 WATTS.
14.ELECTROMAGNETIC WIND DAMPENER IN OPERATOR AS STANDARD
a) THE “WIND BRAKE” HOLDS THE DOOR IN POSITION DURING WIND
LOADS. WHILE THE WIND BRAKE IS ENGAGED YOU MAY ONLY OPERATE
THE DOOR VIA PUSH BUTTON OR MOTION DETECTOR ACTIVATION.
15.OPTIONS: CEMENT ENCASING, CUSTOM TRENCH, TERRAZZO COVER PAN, ALL GLASS
DOOR LEAVES, PATCH FITTINGS, INVISIBLE IN-GLASS TITAN PIVOTS AND MORE…
16.DIMENSIONS:
a) LENGTH = 550MM (22'')
b) WIDTH = 280MM (11'')
c) DEPTH = 150MM (6'')
PART 3 - EXECUTION
3.01 INSTALLATION
A. INSTALL OF THE DRIVE SYSTEM IN PREPARED RECESS IN SLAB WHEN ALL CONDUITS AND
WIRES HAVE BEEN PREPARED TO INSTALL LOCATION.
B. CERTIFY THAT DOOR OPERATION COMPLIES WITH ANSI A156.19 OR A156.10 AS
SPECIFIED.
3.02 CLEANING AND PROTECTION
A. CLEAN EXPOSED OPERATING COMPONENTS AS RECOMMENDED BY BLASI GMBH.
B. PROTECT CONVERTER AND AUTOMATIC DOOR OPERATOR EQUIPMENT FROM DAMAGE AND
DETERIORATION DURING CONSTRUCTION.
END OF SECTION
PRESSURE MATS:
ELECTRODE ASSEMBLY
LOW-VOLTAGE (30VAC/VDC OR LESS) NORMALLY-OPEN CONSTANT
CONTACT SWITCH
HIGH-DURABILITY 24-GAUGE STEEL
18-GAUGE, 12-FOOT, 2-WIRE CORDS
HERMETICALLY ENCAPSULATED SWITCH AND LEAD WIRES
DESIGNED TO MEET IP67 AND NEMA 6
WATER-TIGHT AND TOTALLY SUBMERSIBLE
2 OUTER COVERING
PROPRIETARY MOLDED VINYL
SHORE A HARDNESS 72 ± 2
DIELECTRIC STRENGTH - 300 VOLTS/MIL
RIBBED TO PREVENT SLIPPING
COLORS: BLACK OR BROWN (OTHERS AVAILABLE)
MONOGRAM, LOGOS AND LETTERING CAPABILITIES
3 LOAD CAPACITY
3,000 PSI
TEMPERATURE RANGE
-35ºF TO 120ºF
-37ºC TO 49ºC
5 ACTIVATION SENSITIVITY
5-10 LBS. IN NORMAL FOOT TRAFFIC
CHEMICAL RESISTANCE
EXCELLENT RESISTANCE TO:
ICE
SNOW
SALT (CHLORIDES)
MOST FLOOR CLEANERS (INCLUDING WAX)
PETROLEUM SOLVENTS & OILS
FOR A COMPLETE CHEMICAL RESISTANCE CHART, CONTACT ATEK
DIRECTLY.
ACTUATOR BUTTON:
ARCHITECTURAL SPECIFICATION SHEET
AUTOMATIC AND INDUSTRIAL DOOR SOLUTIONS: PUSH PLATE -
(HARDWIRED)
SENSOR SPECIFICATIONS
ROUND PUSH PLATE FOR SLIDING, SWINGING, FOLDING AND
REVOLVING DOORS AS WELL AS INDUSTRIAL DOORS INCLUDING
OVERHEAD, ROLL-UP AND HIGH SPEED. WIRED PUSH PLATE SHALL
UTILIZE A SINGLE
POLE DRY CONTACT SWITCH CAPABLE OF PROVIDING A NORMALLY
OPEN OR NORMALLY CLOSED CONTACT FOR
DOOR ACTIVATION.
1. PUSH PLATE PROVIDED WITH NO EXPOSED FASTENERS ON THE
FACEPLATE AREA.
2. FACEPLATE UTILIZES AN ABRASIVE ETCH LETTERING
AND/OR LOGO. PUSH PLATES MADE OF PLASTIC, OR
HAVING SURFACE APPLIED PAINTED OR DECALED
LETTERING SHALL NOT BE ACCEPTABLE.
3. STAINLESS STEEL VERTICAL CONFIGURATION PUSH PLATE FOR
WALL MOUNT APPLICATIONS (APPROX 4"W X 36"H).
4. SCREWS COME IN MULTIPLE SIZES (#6 & #8) TO FIT BOTH
SINGLE AND DOUBLE GANG MOUNTING BOXES.
5. BEVELED EDGES PROVIDE A TAMPER AND VANDAL RESISTANT
SOLUTION.
6. 'ALL-ACTIVATE' PLATE ACTIVATES WITH ANY "PUSH" LOCATION.
7. WEATHER BOOT PROVIDED BETWEEN PLATE AND PLATE BACK.
8. HANDICAPPED LOGO AND MARKED PUSH TO OPEN, 4.5 INCHES
(11.43 CM) BY 1.25 INCH (3.19 CM)
9. MODEL 10BOX45RNDSM - ABS SURFACE MOUNT BOX
10. MODEL 10ESCUTCHEON45 - STAINLESS STEEL SURFACE
MOUNT ESCUTCHEON
TECHNICAL SPECS:
FACEPLATE MATERIAL 16 GAUGE, 304 2B STAINLESS STEEL
BACKPLATE MATERIAL 1/8 INCH (.31 CM) THICK, ALUMINUM
MOUNTING SCREWS STAINLESS STEEL, 6-32 × 1 IN & 8-32 × 1 IN
ALLEN HEAD SIZE: 5/64
CHERRY SWITCH SINGLE-POLE, 15 A, COM/NO/NC CONTACT
A0.2
SHEET
SPECIFICATION
TE
XA
S
ST
AT
E
C
AP
IT
O
L
AC
C
ES
SI
BL
E
EN
TR
AN
C E
D O
O R
O
PE
R
AT
O R
S
C
O N
G R
ES
S
AV
E
AU
ST
IN
T
X
BYNO. DATE DESCRIPTION
REVISIONS
DATE:
CHECKED:
DRAWN:
PHASE:
JOB NO.:
JGD
08/30/24
2024-01
JGD
CD
These designs / drawings are the sole property of the Architect, Jacqui Dodson AIA Architecture & Interior Design, Inc. These documents may not be reproduced in any form, by any method, for any purpose without previous written consent from the Architect.
JA
CQ
UE
LINEG.DODSON
08/30/24
2105 ARPDALE STREET
A U S T I N, T X 7 8 7 0 4 5 1 2 . 6 9 9 . 9 7 0 8
PLAN
NORTH
SERVICE CORRIDOR
MECHANICAL ROOM
2'-4"
2"
2'-4"
VESTIBULE
VESTIBULE
2'-4"
2"
2'-4"
2'-4"
2" 2'-4"
SCALE :1 LEVEL 0 ENLARGED PLAN
1/4"=1'-0"
A1.0
DEMO PLANS
GENERAL DEMOLITION NOTES
1. PROTECT FROM DAMAGE EXISTING FINISH WORK THAT IS TO REMAIN IN PLACE AND BECOMES EXPOSED DURING DEMOLITION OPERATIONS.
2. MAINTAIN ALL EMERGENCY EXITING AND FIRE PROTECTION SYSTEMS AND DEVICES THROUGHOUT THE DEMOLITION WORK.
3. ALL EXISTING EXTERIOR WALLS AND DOORS ARE TO REMAIN, U.N.O.
4. MINIMIZE DEMOLITION IN EXCESS OF THAT REQUIRED. RETURN STRUCTURES AND SURFACES TO REMAIN TO CONDITION EXISTING PRIOR TO COMMENCEMENT OF
SELECTIVE DEMOLITION WORK. GC SHALL ENDEAVOR TO PREVENT DAMAGE TO ADJACENT CONSTRUCTION OR SURFACES .
5. WHEN DEMOLITION IS INDICATED OF AN ASSEMBLY, ALL COMPONENTS OF THE ASSEMBLY SHALL BE REMOVED WHETHER HIDDEN WITHIN THE NEW WORK
6. BEFORE DEMOLITION MAY BEGIN, CONTRACTOR SHALL COORDINATE THE TERMINATION AND RELOCATION OF ALL ELECTRICAL SYSTEMS, SWITCHGEAR, EQUIPMENT, ETC.
7. REMOVE ELECTRICAL FIXTURES, WIRING, AND EQUIPMENT AS REQUIRED. REMOVE CONDUIT AND WIRES SERVICING ELECTRICAL EQUIPMENT TO DISTRIBUTION
PANELS UNLESS OTHERWISE APPROVED.
8. EXISTING UTILITIES TO REMAIN ARE TO BE KEPT IN SERVICE THROUGHOUT COURSE OF THE WORK. CERTAIN SERVICE ELEMENTS TO REMAIN MAY BE LOCATED IN
AND THROUGH DEMOLISHED ASSEMBLIES. THE CONTRACTOR AS REQUIRED SHALL REMOVE, REPLACE, AND REROUTE THESE SERVICES.
9. IF UNANTICIPATED MECHANICAL, ELECTRICAL OR STRUCTURAL WHICH CONFLICT WITH INTENDED FUNCTION OR DESIGN ARE ENCOUNTERED, INVESTIGATE AND
MEASURE BOTH NATURE AND EXTENT OF THE CONFLICT. SUBMIT REPORT TO OWNER'S REPRESENTATIVE.
10. UPON COMPLETION OF DEMOLITION WORK, REMOVE TOOLS EQUIPMENT AND DEMOLISHED MATERIALS FROM THE SITE. REMOVE PROTECTION AND LEAVE
INTERIOR AREAS BROOM CLEAN.
11. PROVIDE TEMPORARY WALLS AND PROTECTION AS REQUIRED FOR ADJACENT SPACES.
12. PROVIDE FLOOR PROTECTION WHEN MOVING MATERIAL OR DEBRIS AS INSTRUCTED BY STATE PRESERVATION BOARD.
SCALE :2 LEVEL 1 ENLARGED PLAN
1/4"" = 1'-0"
TE
XA
S
ST
AT
E
C
AP
IT
O
L
AC
C
ES
SI
BL
E
EN
TR
AN
C E
D O
O R
O
PE
R
AT
O R
S
C
O N
G R
ES
S
AV
E
AU
ST
IN
T
X
BYNO. DATE DESCRIPTION
REVISIONS
DATE:
CHECKED:
DRAWN:
PHASE:
JOB NO.:
JGD
08/30/24
2024-01
JGD
CD
These designs / drawings are the sole property of the Architect, Jacqui Dodson AIA Architecture & Interior Design, Inc. These documents may not be reproduced in any form, by any method, for any purpose without previous written consent from the Architect.
JA
CQ
UE
LINEG.DODSON
08/30/24
2105 ARPDALE STREET
A U S T I N, T X 7 8 7 0 4 5 1 2 . 6 9 9 . 9 7 0 8
PLAN
NORTH
DEMO FLOOR PLAN KEYED NOTES
EXISTING DOOR OPERATOR TO BE REMOVED
EXISTING BRONZE THRESHOLDS (SHOWN HATCHED) AND PRESSURE
PLATES AND MATS TO BE REMOVED. MATS ARE TO BE MODIFIED /
RE-USED WHERE POSSIBLE, ALL ELECTRONICS ARE TO BE REPLACED.
GC TO PROVIDE LINE ITEM PRICE TO REPLACE ELECTRONICS AND
MATS. NEW THRESHOLDS THROUGHOUT.
EXISTING PIVOT ARMS TO BE RETAINED. MODIFIED AND RE-USED
WHERE APPLICABLE
EXISTING GRANITE THRESHOLD TO REMAIN INTACT. NO CUTTING OR
CHIPPING.
EXISTING TERRAZZO TO BE DEMOLISHED IN PREPARATION FOR NEW
DOOR OPERATOR HOUSINGS. CUTTING SHALL BE LIMITED TO AREA
OF WORK AS REQUIRED TO MINIMIZE DEMOLITION IN EXCESS OF
WHAT IS REQUIRED FOR THE WORK. REF A1.1
EXISTING WIRELESS CONTROLS FOR OPERATORS TO REMAIN
EXISTING HYDRAULIC CONTROLS TO BE REMOVED
EXISTING HYDRAULIC PIPING TO BE REMOVED (RETAIN EXISTING
PATHWAY FOR NEW ELECTRICAL CONDUIT). DEMOLITION AT LOWER
LEVEL SHALL BE COMPLETED WITH MINIMAL DISTURBANCE TO
EXISTING BRICK AND STONE AT HYDRAULIC PIPING AND ELECTRIC
CONDUIT. GC TO FOLLOW HISTORIC TREATMENT SPECIFICATIONS
FOR WORK IN THIS AREA.
EAST
DOORS
WEST
DOORS
1 1
1 1
5 55 5
SCALE :3 ENLARGED DEMOLITION PLAN
1"=1'-0"
APPROXIMATE
EXTENT OF
EXISTING
TRENCHES
2'-4" 2'-4"
2"
APPROXIMATE
EXTENT OF
EXISTING
TRENCHES
8 8
APPROX LOCATION
OF HYDRAULIC LINES
TO BE REMOVED
(TRENCHES TO BE
UTILIZED FOR NEW
ELECTRICAL LINES
THROUGH FLOOR)
APPROX LOCATION OF
HYDRAULIC LINES TO BE
REMOVED (TRENCHES TO BE
UTILIZED FOR NEW ELECTRICAL
LINES THROUGH FLOOR)
7"
PUSH
TO
OPEN
SCALE :1 LEVEL 0 ENLARGED PLAN
1/4"=1'-0"
A1.1
ELEVS & DETLS
SCALE :2 LEVEL 1 ENLARGED PLAN
1/4"" = 1'-0"
TE
XA
S
ST
AT
E
C
AP
IT
O
L
AC
C
ES
SI
BL
E
EN
TR
AN
C E
D O
O R
O
PE
R
AT
O R
S
C
O N
G R
ES
S
AV
E
AU
ST
IN
T
X
BYNO. DATE DESCRIPTION
REVISIONS
DATE:
CHECKED:
DRAWN:
PHASE:
JOB NO.:
JGD
08/30/24
2024-01
JGD
CD
These designs / drawings are the sole property of the Architect, Jacqui Dodson AIA Architecture & Interior Design, Inc. These documents may not be reproduced in any form, by any method, for any purpose without previous written consent from the Architect.
JA
CQ
UE
LINEG.DODSON
08/30/24
2105 ARPDALE STREET
A U S T I N, T X 7 8 7 0 4 5 1 2 . 6 9 9 . 9 7 0 8
PLAN
NORTH
NEW FLOOR PLAN KEYED NOTES
3/A 1.0
EAST
DOORS
WEST
DOORS
3/A 1.0
NEW DOOR OPERATOR, RECORD USA C127X CENTER PIVOT OR
EQUAL
NEW BRONZE THRESHOLD TO MATCH EXISTING
NEW PRESSURE PLATES, REF SPECIFICATIONS AND ELECTRICAL,
EXISTING PRESSURE MATS TO BE RE-USED WHERE POSSIBLE.
(PROVIDE LINE-ITEM PRICE FOR NEW PRESSURE PLATES AND MATS)
EXISTING PIVOT ARMS TO BE MODIFIED AS NECESSARY. EXISTING
DOORS MAY NOT BE ALTERED TO THE POINT OF VISIBILITY.
BUTT NEW OPERATORS TO EXISTING GRANITE THRESHOLDS
PROVIDE GROUT INFILL AROUND ALL SIDES OF NEW OPERATOR
HOUSINGS PER MANUFACTURER REQUIREMENTS, REF STRUCTURAL
NEW ACTUATOR FOR OPERATORS, REF SPECS (LINE ITEM PRICE TO
REPLACE, BASE BID TO RE-USE EXISTING ACTUATOR)
NEW ELECTRIC CONTROLS PANEL
NEW CONDUIT LOCATIONS
4 4
55 6
4 4
55 6
SCALE :3 WOOD ENTRY DOORS
3/8"=1'-0"
ELEVATION / SECTION @
4/A1.1
SCALE :4 WOOD ENTRY DOORS
1"=1'-0"
OPERATOR ARM AT EXISTING IRON BEAMS
BELOW
EXISTING
BRICK
VAULTS
BEYOND
NEW PIVOT ARM
NEW PIVOT ARM SHALL ALIGN
WITH DOOR IN OPEN POSITION
(APPROX 87 DEGREES MAX
OPENING). EXTERIOR VENEER
TO BE REPAIRED / REPLACED TO
MATCH EXISTING AT REMOVAL
OF EXISTING PIVOT ARM.
VENEER SHALL BE 5
16" OAK
VENEER OVER WHITE PINE
CORE. ALL TOUCH UP PAINTING
TO BE PERFORMED WITH
TNEMEC PAINT.
NEW PLANS,
3/A1.13/A1.1(SIM)
IRON BEAMS, REF LOWER
LEVEL CORRIDOR PLAN
FOR APPROX LOCATION
7"
4'-8" 3' -1
1 4"
2' -6
4"
EXISTING PIVOT ARM
SCALE :6 GLASS DOOR OPERATORS
1-1/2"=1'-0"
ENLARGED PLAN
SCALE :5 WOOD DOOR OPERATORS
1-1/2"=1'-0"
ENLARGED PLAN
NEW CENTER PIVOT OPERATORS
RECORD C127X OR EQUAL
BUTT THIS EDGE OF OPERATOR
HOUSING TO EXISTING GRANITE
THRESHOLD
EXISTING DOOR PIVOT POINT
NEW OPERATOR PIVOT POINT
2"
(V
ER
IF
Y)
NEW CENTER PIVOT OPERATORS
RECORD C127X OR EQUAL
NEW
OPERATOR
PIVOT POINT
ALIGNS WITH
EXISTING
PIVOT
GC TO MODIFY PIVOT ARM TO
ACCOMODATE NEW PIVOT POINT
DOORS IN
CLOSED POSITION
DOORS IN OPEN
POSITION
MODIFY MOUNTING TABS IN FIELD AS
REQUIRED FOR PROXIMITY TO
OPPOSING OPERATOR
LINE ITE PRICE FOR NEW ACTUATION BAR,
HARDWIRE TO OPERATOR, REF SPECS AND
ELEC. GC TO SCRIBE BACK SURFACE OF
ACTUATOR HOUSING TO STONE FACE AS
NEEDED FOR AESTHETICS AND TO PREVENT
WATER INFILTRATION
NEW WIREWAY TO
OPERATOR FROM
ACTUATOR, REF ELEC
GC TO COORDINATE /
RELOCATE ANCHOR STUDS
(PROVIDED WITH HOUSING) AS
REQUIRED TO FASTEN SECURELY
TO SUPPORT TROUGH AND
ADJACENT STRUCTURE
BASE STRUCTURAL
DESIGN: CONCRETE
TROUGH, REF
STRUCTURAL, REF
A1.2 FOR ALTERNATE
STRUCTURAL DESIGN
SHEET METAL
"GUTTER" FOR
VISIBLE DRAIN
PAN BOLTED
TO STONE.
PROVIDE
"PLUG" AT END
OF DRAIN PAN
FOR HOSE
CONNECTION,
PAINT TO
MATCH WALL
DRAIN OUTLET
A1.2
STRUCTURAL
TE
XA
S
ST
AT
E
C
AP
IT
O
L
AC
C
ES
SI
BL
E
EN
TR
AN
C E
D O
O R
O
PE
R
AT
O R
S
C
O N
G R
ES
S
AV
E
AU
ST
IN
T
X
BYNO. DATE DESCRIPTION
REVISIONS
DATE:
CHECKED:
DRAWN:
PHASE:
JOB NO.:
JGD
08/30/24
2024-01
JGD
CD
These designs / drawings are the sole property of the Architect, Jacqui Dodson AIA Architecture & Interior Design, Inc. These documents may not be reproduced in any form, by any method, for any purpose without previous written consent from the Architect.
JA
CQ
UE
LINEG.DODSON
08/30/24
2105 ARPDALE STREET
A U S T I N, T X 7 8 7 0 4 5 1 2 . 6 9 9 . 9 7 0 8
PLAN
NORTH
SCALE :2 SECTION AT NEW DOOR OPERATORS
3""=1'-0"
SCALE :1 SECTION AT DOORS
1"=1'-0"
NEW CENTER PIVOT DOOR
OPERATOR, RELOCATED
PIVOT POINT, GC TO
COORDINATE
MODIFICATION OF PIVOT
ARM WITH NEW PIVOT
POINT, REF STRUCTURAL
DETAIL FOR SECURING
OPERATOR, REF
ELECTRICAL FOR WIRING
HIGH POINT OF EXISTING
BRICK VAULT (BEYOND),
REF LONGITUDINAL
SECTION
COLUMN BEYOND
EXISTING WOOD DOOR
NEW CENTER PIVOT DOOR
OPERATOR, PIVOT POINT
ON GLASS DOORS TO
REMAIN AS IS
EXISTING GLASS DOOR
OUTLINE OF
EXISTING
OPERATOR
NEW
OPERATOR
HOUSING
NEW OPERATOR PIVOT ARM
CENTER POINT
EXISTING
PIVOT
CENTER
POINT
112"
7" 6"
DEPTH OF IRON BEAM
SERVICE
CORRIDOR
BELOW
8"
LINE OF
GRANITE
7"
APPROX 5-6"
EXISTING
DRESSED STONE
FACING
DETAILS &
SCALE :3 DETL @ OPERATORS
nts
OPT 1 STRUCTURAL
SCALE :4 DETL @ OPERATORS
nts
OPT 2 STRUCTURAL
BASE DESIGN -
STRUCTURAL
DETAIL OPTION 1
TO BE USED
UNLESS GC
DISCOVERS THIS
WILL NOT BE
POSSIBLE. GC
TO CONTACT
STRUCTURAL
ENGINEER AFTER
DEMOLITION TO
DETERMINE BEST
COURSE OF
ACTION PRIOR
TO
IMPLEMENTATION
ALTERNATE
STRUCTURAL
DETAIL OPTION 2
PROVIDE
ALTERNATE PRICE
IN THE EVENT THAT
DETAIL #1 IS NOT
POSSIBLE
SHEET METAL
"GUTTER" FOR
VISIBLE DRAIN
PAN BOLTED TO
STONE. REF
PLUMBING.
PAINT TO MATCH
WALL.
RUBBLE FILL
BEHIND (3"-8"
LOOSE
LIMESTONE IN
MORTAR)
STUCCO
/PLASTER
FINISHED
SURFACE
ALL SIDES OF
HOUSING TO BE
GROUTED TO
ADJACENT
SUPPORT
OPERATOR DRAIN OUTLET,
REF PLUMBING
P0.0
PLUMBING
COVER SHEET
TE
XA
S
ST
AT
E
C
AP
IT
O
L
AC
C
ES
SI
BL
E
EN
TR
AN
C E
D O
O R
O
PE
R
AT
O R
S
C
O N
G R
ES
S
AV
E
AU
ST
IN
T
X
BYNO. DATE DESCRIPTION
REVISIONS
DATE:
CHECKED:
DRAWN:
PHASE:
JOB NO.:
MCB
08/30/24
2024-01
MCB
CD
These designs / drawings are the sole property of the Architect, Jacqui Dodson AIA Architecture & Interior Design, Inc. These documents may not be reproduced in any form, by any method, for any purpose without previous written consent from the Architect.
2105 ARPDALE STREET
A U S T I N, T X 7 8 7 0 4 5 1 2 . 6 9 9 . 9 7 0 8
B2AEP, LLC
TBPE F-18874
3510 EAGLE WAY
ROUND ROCK, TX 78681
SIGNED DATE: 8/30/2024
PLUMBING DRAWING LIST
DRAWING # DESCRIPTION
P0.0 PLUMBING COVER SHEET
P0.1 PLUMBING SPECIFICATIONS
P0.2 PLUMBING SPECIFICATIONS
P1.0 PLUMBING PLAN - LEVEL 0 - DEMOLITION
P2.0 PLUMBING PLAN - LEVEL 0 - NEW
P5.0 PLUMBING DETAILS
ABBREVIATION DESCRIPTION
A AMPS
ADD AUTOMATIC AIR DAMPER
ABS ABSOLUTE
ACCU AIR COOLED CONDENSING UNIT
A/C AIR CONDITIONING
AD ACCESS DOOR OR AREA DRAIN
ADA AMERICAN DISABILITIES ACT
ADJ ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
AMB AMBIENT
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
AP ACCESS PANEL
APD AIR PRESSURE DROP
~ APPROXIMATELY
ARCH ARCHITECT
AS AIR SEPARATOR
AVG AVERAGE
BDD BACKDRAFT DAMPER
BHP BRAKE HORSEPOWER
BFP BACKFLOW PREVENTOR
CA COMPRESSED AIR
CAV CONSTANT AIR VOLUME
CCW COUNTER CLOCKWISE
CD CONDENSATE DRAIN
CFM CUBIC FEET PER MINUTE
CFOI CONTRACTOR FURNISHED / OWNER INSTALLED
CFS CUBIC FEET PER SECOND
CH CHILLER
CHWM CHILLED WATER MAKE-UP
CHWP CHILLED WATER PUMP
CHWPP CHILLED WATER PRIMARY PUMP
CHWR CHILLED WATER RETURN
CHWS CHILLED WATER SUPPLY
CHWSP CHILLED WATER SECONDARY PUMP
CI CAST IRON
CLG CEILING
CLG HT CEILING HEIGHT
CW CLOCKWISE
CO CLEAN-OUT, CARBON MONOXIDE
CO2 CARBON DIOXIDE
COL COLUMN
CONC CONCRETE
COP COEFFICIENT OF PERFORMANCE (HEATING)
CP CONDENSATE PUMP
CT COOLING TOWER
CU CONDENSING UNIT
CV CONSTANT VOLUME
CW COLD WATER
CWP CONDENSER WATER PUMP
CWR CONDENSER WATER RETURN
CWS CONDENSER WATER SUPPLY
dB DECIBEL(S)
DB DRY BULB TEMPERATURE
DDC DIRECT DIGITAL CONTROL
DEG DEGREE(S)
DF DRINKING FOUNTAIN
DH DUCT HEATER
DIA DIAMETER
DP DEW POINT
DPT DEW POINT TEMPERATURE
D DRAIN
DT DELTA TEMPERATURE
DYCO DOUBLE YARD CLEAN-OUT
EAT ENTERING AIR TEMPERATURE
ECON ECONOMIZER
EDB ENTERING DRY BULB
EDH ELECTRIC DUCT HEATER
EER ENERGY EFFICIENCY RATIO
EF EXHAUST FAN
EFF EFFICIENCY
ELEC ELECTRIC
ENT ENTERING
EQIV FT EQUIVALENT FEET
EQP EQUIPMENT
ESP EXTERNAL STATIC PRESSURE
ET EXPANSION TANK
EUH, EH ELECTRIC (UNIT) HEATER
EVAP EVAPORAT(E), (IVE)
EWB ENTERING WET BULB
EWH ELECTRIC WATER HEATER
EWT ENTERING WATER TEMPERATURE
EXH EXHAUST
EXT EXTERIOR
F FAHRENHEIT
FA FREE AREA
FC FLEXIBLE CONNECTION
FCO FLOOR CLEAN-OUT
FCU FAN COIL UNIT
FD FLOOR DRAIN, FIRE DAMPER
FDC FIRE DEPARTMENT CONNECTION
FF FINAL FILTERS
FHC FIRE HOSE CABINET
FLR FLOOR
FPC FIRE PROTECTION CONTRACTOR
FS FLOOR SINK
FPTU FAN POWERED TERMINAL UNIT
FTLB FOOT POUND
FPM FEET PER MINUTE
FPS FEET PER SECOND
FRP FIBERGLASS REINFORCED PLASTIC
FV FACE VELOCITY
G NATURAL GAS
GA GAGE
GAL GALLON
GC GENERAL CONTRACTOR
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GPS GALLONS PER SECOND
GT GREASE TRAP
H HEIGHT
HB HOSE BIB
HD HEAD
HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)
HOA HAND, OFF, AUTO STATION
HP HORSEPOWER
HR HOUR
HS HAND SINK
HSTAT HUMIDISTAT
HT HEIGHT
HTR HEATER
HVAC HEATING, VENTILATION, AND AIR CONDITIONING
HW HOT WATER
HWC HOT WATER COIL
HWCP HOT WATER CIRCULATING PUMP
HWP HOT WATER PUMP
HWR HOT WATER RETURN
HWS HOT WATER SUPPLY
HWT HOT WATER TANK
HZ FREQUENCY
IAQ INDOOR AIR QUALITY
ID INSIDE DIAMETER
IN WC INCHES, WATER COLUMN
INCL INCLUDE
INSUL INSULAT(E), (ED), (ION)
INT INTERIOR
INV INVERT
I/O INPUT/OUTPUT
IPS INTERNATIONAL PIPE STANDARD
IPT IRON PIPE THREADED
IWH INSTANTANEOUS WATER HEATER
ABBREVIATION DESCRIPTION
JS JANITOR SINK
KEC KITCHEN EQUIPMENT CONTRACTOR
KW KILOWATT
KWH KILOWATT HOUR
LAT LEAVING AIR TEMPERATURE
LAV LAVATORY
LB POUND
LDB LEAVING DRY BULB
L LENGTH
LF LINEAR FEET
LOC LIMITS OF CONSTRUCTION
LP LOW PRESSURE
LWT LEAVING WATER TEMPERATURE
MAT MIXED AIR TEMPERATURE
MAU MAKE UP AIR UNIT
MAX MAXIMUM
MBH BTH/HR X 1,000
MC MECHANICAL CONTRACTOR
MD MOTORIZED DAMPER
MECH MECHANICAL
MIN MINIMUM
MISC MISCELLANEOUS
MPT MALE PIPE THREAD
MTL METAL
MVD MANUAL VOLUME DAMPER
MZ MULTIZONE
NA NOT APPLICABLE
NC NOISE CRITERIA
N.C. NORMALLY CLOSED
NIC NOT IN CONTRACT
N.O. NORMALLY OPEN
NTS NOT TO SCALE
OA OUTSIDE AIR
OAD OUTSIDE AIR DAMPER
OAT OUTSIDE AIR TEMPERATURE
OBD OPPOSED BLADE DAMPER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED / CONTRACTOR INSTALLED
OFD OVERFLOW DRAIN
OFOI OWNER FURNISHED / OWNER INSTALLED
OZ OUNCE
P PUMP
PCT PERCENT
PD PRESSURE DROP/DIFFERENCE
PF PRE-FILTER
PH PHASE
PLBG PLUMBING
POC POINT OF CONNECTION
PPM PARTS PER MILLION
PRS PRESSURE REDUCING STATION
PRV PRESSURE REDUCING VALVE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH, ABSOLUTE
PSIG POUNDS PER SQUARE INCH, GAGE
PTAC PACKAGED TERMINAL AIR CONDITIONER
PVC POLYVINYL CHLORIDE
QT QUART
QTY QUANTITY
RA RETURN AIR
RAF RETURN AIR FAN
RAT RETURN AIR TEMPERATURE
RCP REINFORCED CONCRETE PIPE
RD ROOF DRAIN
REF REFRIGERATOR
RH RELATIVE HUMIDITY
RHC REHEAT COIL
RM ROOM
RPM REVOLUTIONS PER MINUTE
RPS REVOLUTIONS PER SECOND
RTU ROOF TOP UNIT
RV RELIEF VALVE
SA SUPPLY AIR
SAF SUPPLY AIR FAN
SAN SANITARY
SAT SATURATED
SCFM STANDARD CUBIC FEET PER MINUTE
SCFS STANDARD CUBIC FEE PER SECOND
SD SMOKE DAMPER, STORM DRAIN
SEC SECOND(S)
SFD SMOKE/FIRE DAMPER
SH SHOWER
SHT SHEET
SK SINK
SP SUMP PUMP
SPEC SPECIFICATIONS
SS SERVICE SINK, SANITARY SEWER, STORM
SEWER, STAINLESS STEEL
STC SOUND TRANSMISSION CLASS
STD STANDARD
T TEMPERATURE
T&P TEMPERATURE AND PRESSURE VALVE
T/S TUB/SHOWER COMBINATION
TAB TEST ADJUST & BALANCE
TD TEMPERATURE DIFFERENCE
TDH TOTAL DYNAMIC HEAD
TDV TRIPLE DUTY VALVE
TEMP TEMPERATURE
TONS TONS OF REFRIGERATION
TSTAT THERMOSTAT
TYP TYPICAL
U HEAT TRANSFER COEFFICIENT
UC UNDERCUT, UNDER COUNTER
UH UNIT HEATER
UNO UNLESS NOTED OTHERWISE
UR URINAL
UV UNIT VENTILATOR
V VENT, VOLTS
VA VOLT AMPERE
VAC VACUUM
VAV VARIABLE AIR VOLUME
VFD VARIABLE FREQUENCY DRIVE
VRF VARIABLE REFRIGERANT FLOW
VRV VARIABLE REFRIGERANT VOLUME
VEL VELOCITY
VERT VERTICAL
VOL VOLUME
VTR VENT THROUGH THE ROOF
VVT VARIABLE VOLUME TERMINAL
W WASTE, WIDTH
W/ WITH
W/O WITHOUT
WB WET BULB
WC WATER CLOSET
WCO WALL CLEAN-OUT
WH WALL HYDRANT
WHA WATER HAMMER ARRESTOR
WM WATER METER
WT WEIGHT
WTR WATER
YCO YARD CLEAN-OUT
YD YARD
YR YEAR
ZN ZONE
ABBREVIATIONS PLUMBING GENERAL NOTES
A. REFER TO THE PLUMBING PLANS FOR DEMOLITION, NEW WORK, AND ADDITIONAL
INFORMATION.
B. REFER TO THE PLUMBING SPECIFICATIONS, SCHEDULES, RISERS, AND DETAIL
DRAWINGS FOR ADDITIONAL INFORMATION.
C. CONTRACTOR SHALL FIELD VERIFY ACTUAL LOCATIONS OF ALL EQUIPMENT,
DUCTWORK, & PIPING PRIOR TO SUBMITTING A BID. COORDINATE COMPLETELY
WITH ALL OTHER TRADES. RELOCATE TERMINAL UNITS AND PROVIDE
ADDITIONAL DUCTWORK, OFFSETS, FITTINGS, ETC. AS REQUIRED.
D. THE CONTRACTOR SHALL VERIFY THAT ALL EXISTING AND NEW PLUMBING
EQUIPMENT ARE MOUNTED SO THAT ALL REQUIRED CODE AND
MANUFACTURER'S SERVICES CLEARANCES ARE MAINTAINED AT THE BOTTOM
AND SIDES OF EACH UNIT FOR PROPER SERVICING AND MAINTENANCE.
COORDINATE COMPLETELY WITH ALL NEW WALLS TO STRUCTURE, AND
RELOCATE AS REQUIRED TO MAINTAIN PROPER CLEARANCES.
E. REFER TO THE ARCHITECTURAL PLANS AND DETAILS FOR EXACT LOCATIONS
AND MOUNTING HEIGHTS OF ALL PLUMBING FIXTURES, FLOOR DRAINS, FLOOR
SINKS, ETC.
F. ALL SANITARY PIPING SHALL BE SLOPED AS PER CODE BASED UPON PIPE SIZE.
G. THE PLUMBING CONTRACTOR SHALL COORDINATE EXACT ROUTING OF ALL
PIPING WITH THE WORK OF ALL OTHER TRADES. PROVIDE OFFSETS IN PIPING
WHERE REQUIRED BY COORDINATION OF TRADES.
H. THE PLUMBING CONTRACTOR SHALL CLEAN, FLUSH, AND DISINFECT ALL COLD
WATER AND HOT WATER PIPING AND ALL FIXTURES PRIOR TO COMPLETION OF
WORK.
I. INSTALL ALL FLOOR DRAINS AND FLOOR SINKS SUCH THAT GRATING IS FLUSH
WITH ADJACENT FLOORING SURFACE. FLOOR SHALL SLOPE TO DRAINS NOT
FLOOR SINKS. COORDINATE ALL REQUIREMENTS WITH ARCHITECT AND GENERAL
CONTRACTOR PRIOR TO INSTALLATION.
J. VENTS THROUGH ROOF TO BE LOCATED A MINIMUM OF 10'-0" HORIZONTALLY
AWAY FROM OUTSIDE AIR INTAKES.
K. FLOOR DRAINS NOT RECEIVING REGULAR-USE DRAINAGE ARE TO BE TRAP
PRIMERED.
L. PROVIDE BACKFLOW PREVENTION AS REQUIRED BY THE LOCAL CROSS
CONNECTION CONTROL DEPARTMENT STANDARDS WHERE NOT PROVIDED OR
INADEQUATELY PROVIDED, BY EQUIPMENT MANUFACTURER.
M. INSTALL PIPING AS HIGH AS POSSIBLE UNLESS NOTED OTHERWISE.
N. VERIFY DIMENSIONS FROM ARCHITECTURAL DRAWINGS AND FROM ACTUAL
MEASUREMENTS AT JOBSITE.
O. PROVIDE SADDLES AND SHIELDS FOR SUPPORT OF INSULATED PIPING TO
PREVENT CRUSHING.
P. PIPING PENETRATIONS THROUGH PERIMETER BEAMS, FOUNDATION ON GRADE,
AND STRUCTURAL FLOORS SHALL BE SLEEVED. COORDINATE SLEEVE
LOCATIONS AND SIZES WITH STRUCTURAL PRIOR TO POUR.
Q. PROVIDE DIELECTRIC UNIONS AT DISSIMILAR MATERIALS.
R. PROVIDE ESCUTCHEONS AT ALL FINISHED WALL AND CEILING PIPING
PENETRATIONS.
S. ALL PIPING SHALL BE IDENTIFIED AS TO TYPE OF USE, SERVICE, AND DIRECTION
OF FLOW. LOCATE MARKERS AT EACH VALVE, AT ENTRIES TO WALLS, AND ON
20-FOOT CENTERS ON STRAIGHT RUNS OF PIPE. PROVIDE A FLOW ARROW AT
EACH IDENTIFICATION MARKER. PIPE MARKERS SHALL BE SETON "SETMARK" OR
EQUAL.
T. COORDINATE WORK COMPLETELY WITH ALL OTHER TRADES.
U. INSTALL PIPING FREE OF SAGS AND BENDS. PROVIDE NON-METALLIC COATED
HANGERS WHERE IN DIRECT CONTACT WITH COPPER PIPING.
V. PROVIDE ENGINEERED WATER HAMMER ARRESTERS SIZED AND PLACED IN
ACCORDANCE WITH STANDARD PDI-WH 201. AIR CHAMBERS SHALL NOT BE
ALLOWED.
W. PROVIDE FLEXIBLE EXPANSION FITTINGS SUITABLE FOR SANITARY (DWV) AND
RAINWATER PIPING WHERE PIPING ENTERS EXPANSIVE SOILS TO ALLOW FOR
4-IN OF DIFFERENTIAL MOVEMENT.
X. MAKE ALL NECESSARY EXCAVATIONS, CUTTING OF PAVING, CONCRETE, ETC.,
REMOVAL OF UNUSABLE SPOIL MATERIAL, DO ALL BACKFILLING WITH STABILIZED
FILL, AND DO TEMPORARY PATCH PAVING REPAIRS NECESSARY FOR PROPER
EXECUTION OF THE WORK. BACKFILL SHALL BE MECHANICALLY COMPACTED TO
A DENSITY OF 95% OF THE MAXIMUM DRY DENSITY AT OPTIMUM MOISTURE
CONTENT AS DETERMINED BY THE STANDARD PROCTOR COMPACTION TEST.
Y. SADDLE CLAMPS SHALL NOT BE PERMITTED AT 1/4" CW PIPING STUB-OUTS FOR
ICE MAKERS AND COFFEE MAKERS.
Z. PROVIDE MINIMUM 1" AIR GAP OR 2 TIMES THE PIPE DIAMETER, WHICHEVER IS
GREATER, AT DRAIN DISCHARGE FOR ALL INDIRECT WASTE DISCHARGE PIPING.
AA. PROVIDE A MINIMUM 1" AIR GAP OR 2 TIMES THE PIPE DIAMETER, WHICHEVER IS
GREATER, ABOVE THE FLOOD RIM OF A JANITOR SINK FOR ALL INDIRECT WASTE
DISCHARGE PIPING.
AB. DISCHARGE PIPING FROM A DISHWASHER SHALL BE LOOPED UP AND SECURELY
FASTENED TO THE UNDERSIDE OF THE COUNTER OR AN APPROVED
DISHWASHER AIR-GAP FITTING IS REQUIRED.
AC. COMPRESSION TANKS SUPPLIED AT EACH WATER HEATER SHALL BE SECURED
TO A WALL WITH (2) 1" X 14 GA. GALVANIZED STRAPS. PROVIDE LAG BOLTS AND
BLOCKING AS REQUIRED.
AD. AN ATMOSPHERIC VACUUM BREAKER OR OTHER APPROVED BACKFLOW
PREVENTION DEVICE MUST BE INSTALLED ON ALL THREADED HOSE BIBB, WALL
HYDRANT OR THREADED FAUCET CONNECTIONS LOCATED INSIDE OR OUTSIDE
THE BUILDING.
SYMBOL DESCRIPTIONSYMBOL DESCRIPTION
PLUMBING SYMBOLS
days 2 working
CALL 811
COLD WATER SUPPLY
NON-POTABLE WATER
HOT WATER SUPPLY
140°F HOT WATER SUPPLY
HOT WATER RETURN
TRAP PRIMER
COMPRESSED AIR
NATURAL GAS
FIRE MAIN, STANDPIPE
SPRINKLER, DRY OR WET
PLUMBING VENT
PUMP DISCHARGE
SANITARY, ABOVE GRADE
SANITARY, BELOW GRADE
STORM, ABOVE GRADE
STORM, BELOW GRADE
OVERFLOW, ABOVE GRADE
OVERFLOW, BELOW GRADEOD
OD
RD
RD
SS
PD
S
F
G
A
NPW
FLOOR DRAIN
FLOOR SINK
ROOF DRAIN
CLEAN-OUT: WALL, FLOOR, YARD,
DOUBLE
HOSE BIBB, WALL HYDRANT
PIPING AND EQUIPMENT SHOWN
LIGHT AND SOLID ARE FURNISHED
BY OTHERS
EXISTING PIPING AND EQUIPMENT
SHOWN LIGHT LINES
NEW TO EXISTING CONNECTION
LOCATION
DEMOLISH TO THIS POINT
FIRE HOSE VALVE
ALARM VALVE
DRY-PIPE VALVE
POST-INDICATOR VALVE
DETECTOR CHECK VALVE
STANDPIPE BASE VALVE
FIRE DEPARTMENT CONNECTION
RELIEF VALVE
GATE VALVE
OS&Y VALVE
CIRCUIT SETTER
GLOBE VALVE
CIRCUIT SOLVER
BALL VALVE
CHECK VALVE
BUTTERFLY VALVE
PLUG VALVE
PRESSURE REGULATING VALVE
SOLENOID VALVE
STRAINER
SLEEVE
UNION
SHOCK ARRESTER AND SIZE ('X')
WATER CONNECTION, WALL BOX
DWH-1 EQUIPMENT TAG, FIXTURE TAG
EQUIPMENT
P0.1
SPECIFICATIONS
TE
XA
S
ST
AT
E
C
AP
IT
O
L
AC
C
ES
SI
BL
E
EN
TR
AN
C E
D O
O R
O
PE
R
AT
O R
S
C
O N
G R
ES
S
AV
E
AU
ST
IN
T
X
BYNO. DATE DESCRIPTION
REVISIONS
DATE:
CHECKED:
DRAWN:
PHASE:
JOB NO.:
MCB
08/30/24
2024-01
MCB
CD
These designs / drawings are the sole property of the Architect, Jacqui Dodson AIA Architecture & Interior Design, Inc. These documents may not be reproduced in any form, by any method, for any purpose without previous written consent from the Architect.
2105 ARPDALE STREET
A U S T I N, T X 7 8 7 0 4 5 1 2 . 6 9 9 . 9 7 0 8
B2AEP, LLC
TBPE F-18874
3510 EAGLE WAY
ROUND ROCK, TX 78681
SIGNED DATE: 8/30/2024
PART 1 - GENERAL
1.1 SECTION INCLUDES
A. PLUMBING EQUIPMENT, PIPING, FIXTURES, ACCESSORIES, ASSOCIATED TRIM, INSULATION, HANGERS, AND SUPPORTS.
1.2 RELATED SECTIONS
A. SCOPE OF WORK
1. THE CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, SUPPLIES, MATERIALS, TOOLS,
LABOR, ETC...FOR A COMPLETE INSTALLATION.
2. THE CONTRACTOR SHALL COORDINATE ALL OF THE CONSTRUCTION WORK WITH ALL
OTHER TRADES ON THIS PROJECT.
3. THE CONTRACTOR SHALL PROVIDE A COMPLETE PLUMBING SYSTEM AS SHOWN ON THE
DRAWINGS AND SPECIFIED BY NOTES AND/OR THE SPECIFICATIONS.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REVIEWING ALL DRAWINGS AND
SPECIFICATIONS FOR SCOPE OF WORK THAT SHALL BE COMPLETED FOR THIS PROJECT.
5. THE CONTRACTOR SHALL REVIEW SITE CONDITIONS ALONG WITH THE CONTRACT
DOCUMENTS TO ASCERTAIN THE COMPLETE SCOPE OF WORK FOR THE PROJECT.
6. THE CONTRACTOR SHALL FIELD VERIFY ALL SITE MEASUREMENTS WITH REGARDS TO
THE SCOPE OF WORK TO ACCOUNT FOR ALL REQUIRED DIMENSIONAL ADJUSTMENTS. NO
ADDITIONAL COMPENSATION SHALL BE ALLOWED FOR ANY DISCREPANCIES BETWEEN
DIMENSIONS INDICATED ON THE CONTRACT DOCUMENTS AND ACTUAL FIELD
MEASUREMENTS.
1.3 REFERENCES
A. AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME)
B. AMERICAN SOCIETY OF PLUMBING ENGINEERS (ASPE)
C. AMERICAN SOCIETY OF SAFETY ENGINEERS (ASSE)
D. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM)
E. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
F. UNDERWRITERS LABORATORY (UL)
1. LISTED PRODUCTS
1.4 SUBMITTALS
A. THE CONTRACTOR SHALL SUBMIT AN ELECTRONIC COPY OF THE SHOP DRAWINGS,
EQUIPMENT PERFORMANCE SUBMITTALS, AND PRODUCT DATA FOR THE FOLLOWING ITEMS:
1. EQUIPMENT
2. PIPING
3. INSULATION
4. FIXTURES
5. TRIM/ACCESSORIES
6. ALL OTHER INSTALLED PLUMBING ITEMS
B. SHOP DRAWINGS
1. INCLUDE SYSTEM COMPONENTS
2. APPLICABLE DIMENSIONAL DATA
3. DIMENSIONS TO ADJACENT CONSTRUCTION AND/OR OBSTRUCTIONS
4. ALL REQUIRED CLEARANCES AND ACCESS DIMENSIONS FOR SERVICING
C. EQUIPMENT WEIGHTS
1. THE CONTRACTOR SHALL INCLUDE EQUIPMENT WEIGHTS ON ALL SUBMITTALS TO VERIFY
WHICH PIECES OF EQUIPMENT WEIGH 300 POUNDS OR MORE.
D. HAZARDOUS MATERIALS, PRODUCTS, PROCESSES, AND VOC'S
1. IN THE EVENT THAT MATERIALS, PRODUCTS, AND/OR PROCESSES BEING PROPOSED FOR
THIS PROJECT CONTAIN, OR MAY EMIT, ANY VOLATILE ORGANIC COMPOUNDS (VOC),
FORMALDEHYDE FORMULATIONS, OR HAZARDOUS OUT-GASSING, AS DETERMINED BY
THE MANUFACTURER, A MATERIALS SAFETY DATA SHEET SHALL BE SUBMITTED AS PART
OF THE SHOP DRAWING PROCESS FOR REVIEW BY THE ARCHITECT, ENGINEER, AND
OWNER.
E. SUBSTITUTIONS OF EQUIPMENT OR MATERIALS
1. THE CONTRACTOR SHALL NOT SUBSTITUTE EQUIPMENT OR MATERIAL WITHOUT PRIOR
WRITTEN AUTHORIZATION FROM THE ENGINEER OF RECORD AND OWNER.
2. THE DETERMINATION OF WHAT SHALL BE CONSIDERED EQUAL IS AT THE SOLE
DISCRETION OF THE ENGINEER OF RECORD AND OWNER.
3. THE CONTRACTOR SHALL INCLUDE SUFFICIENT DESCRIPTIVE INFORMATION, INCLUDING
BUT NOT LIMITED TO THE MANUFACTURER'S PUBLISHED DATA TO ESTABLISH CONTRACT
COMPLIANCE.
4. THE CONTRACTOR SHALL SUBMIT SAMPLES IF REQUESTED BY THE ARCHITECT OR
ENGINEER OF RECORD.
5. ALL SUBSTITUTIONS SHALL BE SUBMITTED AT LEAST SEVEN (7) DAYS PRIOR TO BID
SUBMISSION FOR REVIEW.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION AND ALL
ASSOCIATED COSTS FOR ALL DIMENSIONAL DIFFERENCES, WEIGHTS, CLEARANCES,
MATERIAL & LABOR FOR…