About this file
This is a Scope of Work document from the Texas Department of Public Safety (TXDPS) for the construction of a 40-foot monopole telecommunications tower at 11612 Scott Simpson Dr. in El Paso, Texas. The project requires construction of a steel tube tower meeting TIA 222-H design standards, with a 93% tower rating and cable port entry/exit at 12 feet height. All feedlines must be inside the pole, and the structure must use hot-dipped galvanized steel construction with specific material requirements including 42 KSI minimum yield HSS round tube. TXDPS will provide the Dragonwave antenna and radio equipment, including a 2-foot 11 GHz antenna and Harmony Enhanced radio. The contractor must coordinate with TXDPS technicians with 7 days notice before beginning work, and TXDPS will coordinate blocking off the office parking lot during construction.
The document includes aerial and ground-level photos showing the installation site at the Scott Simpson Office, including views of the brick building exterior and proposed monopole location. The site photos show a paved area with surrounding landscaping where the monopole will be installed. Contractors must maintain daily cleanup of the work area and properly dispose of all project debris upon completion. The document does not specify pricing terms or set-asides, but includes detailed technical specifications for materials and construction standards, including options for backfill material using either 3000 PSI concrete or crushed aggregate compacted to 95% standard proctor density.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Scott Simpson Office 40’ Monopole
Description:
TXDPS Radio Shop is requiring the construction of a 40 ft monopole located at 11612 Scott Simpson Dr., El Paso Tx 79936 (31 44 41.24 N, 106 17 59.96).
Job Requirements:
• Construction of a 40 ft monopole steel tube tower to industry standards (listed below) with cable port entry/exit on pole at approx. 12 ft height
1. DESIGN MEETS THE REQUIREMENTS OF THE TIA 222-H DESIGN STANDARD.
2. ALL FEEDLINES TO BE INSIDE POLE.
3. HSS ROUND TUBE SHALL BE 42 KSI MINIMUM YIELD (A500-B). PIPE SHALL BE 35 KSI MINIMUM
YIELD (A53-B). PLATE SHALL BE 50 KSI MINIMUM YIELD (A572-50).
4. BOLTS SHALL BE ASTM A325. ALL-THREAD SHALL BE ASTM F1554-105. NUTS SHALL BE ASTM A563
GRADE "DH" OR BETTER. WASHERS SHALL BE ASTM F436.
5. ALL STEEL SHALL BE HOT DIPPED GALVANIZED PER ASTM A123.
6. CONNECTIONS ARE DESIGNED TO SUPPORT THE DESIGN LOAD OF THE MEMBERS.
7. ALL CONNECTIONS (WELDED AND BOLTED) CONFORM TO AISC "MANUAL OF STEEL
CONSTRUCTION" LATEST EDITION.
8. BACKFILL MATERIAL OPTIONS:
1. 3000 PSI CONCRETE
2. CRUSHED AGGREGATE COMPACTED TO 95% STANDARD PROCTOR DENSITY
9. SOIL ASSUMPTION: DIRECT BURY SECTION DESIGNED TO BE USED IN SOILS THAT MEET OR
EXCEED PRESUMPTIVE, CLAY PER TIA 222-H, ANNEX F.
10. TOWER RATING: 93%
• Engineering of 40 ft monopole steel tube tower provided to TXDPS by bidder prior to construction
• Line and antenna/radio installation for – o Dragonwave (T556A11T.06) 2' / 60cm, 11 GHz Antenna, Clip-Mount RFE o DragonWave (T562RH11B01S0.11) Radio, Harmony Enhanced 11 GHz Band 1 TxH
Materials provided by TXDPS Radio Shop:
• Line and antenna for:
o Dragonwave (T556A11T.06) 2' / 60cm, 11 GHz Antenna, Clip-Mount RFE o DragonWave (T562RH11B01S0.11) Radio, Harmony Enhanced 11 GHz Band 1 TxH
• Texas DPS will coordinate the blocking off of the office parking lot during the duration of work
Tony Garcia, the El Paso TXDPS technician, will be on-site during the duration of work at the facility; Cell Phone Contact Number: 915-217-6552. If the listed technician becomes unavailable, an alternate technician will be designated, and will be on-site for all tower work-related tasks. Call the designated TX DPS Radio Technician a minimum of seven (7) calendar days in advance of beginning on-site tower work to ensure the required technician(s) will be available during the scheduled on-site tower work.
Clean up:
The Contractor must clean up all work areas on an ongoing daily basis as work progresses. Upon completion of the work at the site, all staging and debris from the project must be removed and disposed of properly.