About this file
This is a scope of work document from the Texas Department of Public Safety (TXDPS) Radio Shop for the construction of a 40-foot monopole telecommunications tower at 11612 Scott Simpson Dr., El Paso TX 79936. The project requires construction of a steel tube tower meeting TIA 222-H design standards, with engineering plans to be provided by the bidder prior to construction. The tower will support Dragonwave antenna and radio equipment (which will be provided by TXDPS), including a 2-foot/60cm 11 GHz antenna and Harmony Enhanced radio. The installation requires a cable port entry/exit at approximately 12 feet height, with all feedlines to be inside the pole. TXDPS will coordinate parking lot blocking during construction, and a TXDPS technician must be notified 7 days before work begins to ensure on-site availability.
The technical specifications require hot-dipped galvanized steel construction per ASTM A123, with specific material requirements including 42 KSI minimum yield HSS round tube, 35 KSI minimum yield pipe, and 50 KSI minimum yield plate. Foundation options include either 3000 PSI concrete or crushed aggregate compacted to 95% standard proctor density. The tower is designed for clay soil conditions per TIA 222-H Annex F and has a 93% rating. Daily cleanup is required during construction with complete removal of all staging and debris upon project completion. The site location is shown in aerial photographs, depicting the installation area adjacent to a brick building with existing telecommunications infrastructure nearby.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Scott Simpson Office 40’ Monopole
Description:
TXDPS Radio Shop is requiring the construction of a 40 ft monopole located at 11612 Scott Simpson Dr., El Paso Tx 79936 (31 44 41.24 N, 106 17 59.96).
Job Requirements:
• Construction of a 40 ft monopole steel tube tower to industry standards (listed below) with cable port entry/exit on pole at approx. 12 ft height
1. DESIGN MEETS THE REQUIREMENTS OF THE TIA 222-H DESIGN STANDARD.
2. ALL FEEDLINES TO BE INSIDE POLE.
3. HSS ROUND TUBE SHALL BE 42 KSI MINIMUM YIELD (A500-B). PIPE SHALL BE 35 KSI MINIMUM
YIELD (A53-B). PLATE SHALL BE 50 KSI MINIMUM YIELD (A572-50).
4. BOLTS SHALL BE ASTM A325. ALL-THREAD SHALL BE ASTM F1554-105. NUTS SHALL BE ASTM A563
GRADE "DH" OR BETTER. WASHERS SHALL BE ASTM F436.
5. ALL STEEL SHALL BE HOT DIPPED GALVANIZED PER ASTM A123.
6. CONNECTIONS ARE DESIGNED TO SUPPORT THE DESIGN LOAD OF THE MEMBERS.
7. ALL CONNECTIONS (WELDED AND BOLTED) CONFORM TO AISC "MANUAL OF STEEL
CONSTRUCTION" LATEST EDITION.
8. BACKFILL MATERIAL OPTIONS:
1. 3000 PSI CONCRETE
2. CRUSHED AGGREGATE COMPACTED TO 95% STANDARD PROCTOR DENSITY
9. SOIL ASSUMPTION: DIRECT BURY SECTION DESIGNED TO BE USED IN SOILS THAT MEET OR
EXCEED PRESUMPTIVE, CLAY PER TIA 222-H, ANNEX F.
10. TOWER RATING: 93%
• Engineering of 40 ft monopole steel tube tower provided to TXDPS by bidder prior to construction
• Line and antenna/radio installation for – o Dragonwave (T556A11T.06) 2' / 60cm, 11 GHz Antenna, Clip-Mount RFE o DragonWave (T562RH11B01S0.11) Radio, Harmony Enhanced 11 GHz Band 1 TxH
Materials provided by TXDPS Radio Shop:
• Line and antenna for:
o Dragonwave (T556A11T.06) 2' / 60cm, 11 GHz Antenna, Clip-Mount RFE o DragonWave (T562RH11B01S0.11) Radio, Harmony Enhanced 11 GHz Band 1 TxH
• Texas DPS will coordinate the blocking off of the office parking lot during the duration of work
Tony Garcia, the El Paso TXDPS technician, will be on-site during the duration of work at the facility; Cell Phone Contact Number: 915-217-6552. If the listed technician becomes unavailable, an alternate technician will be designated, and will be on-site for all tower work-related tasks. Call the designated TX DPS Radio Technician a minimum of seven (7) calendar days in advance of beginning on-site tower work to ensure the required technician(s) will be available during the scheduled on-site tower work.
Clean up:
The Contractor must clean up all work areas on an ongoing daily basis as work progresses. Upon completion of the work at the site, all staging and debris from the project must be removed and disposed of properly.