ESBD_384210_1737736316433_CSRFP 2024-25-003 - Addendum 1 E-Rate Cat 2 Equipment Services & Cabling - FINAL.pdf

PDF 215 KB Posted

Attached to
E-RATE CAT 2 EQUIPMENT, SERVICES AND CABLING
Solicitation number
CSRFP2024-25-003
Issued by
Galveston County, Texas

About this file

This is Addendum No. 1 to CSRFP 2024-25-003 for E-Rate Category 2 Equipment, Services, and Cabling issued by Galveston Independent School District (GISD). The addendum provides clarification on technical specifications through a Q&A format addressing network equipment requirements and infrastructure standards.

The addendum specifies that redundant power and stackability are required for all switches, including access layer/IDF switches. The fiber interconnect speed requirement is set at 10GB, and the current fiber optic network uses Single Mode standard. Regarding cabling standards, GISD currently uses Cat 6 throughout most facilities, while the new Ball High School employs a Corning fiber to the edge solution with Cat 6a cabling to endpoints. Questions regarding the procurement can be directed to Ana Escobar, the Purchasing Coordinator, at anaescobar@gisd.org.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ADDENDUM NO. 1

E-Rate Cat 2: Equipment, Services, & Cabling

CSRFP 2024-25-003

The following clarifications, amendments, deletions, additions, revision and/or modifications are made as part of the contract documents and change the original documents only in the manner and to the extent hereinafter stated and shall be incorporated in the contract documents.

The provisions of this addendum shall take precedence over requirements of the original documents released.

PROPOSERS ARE REQUESTED TO ACKNOWLEDGE SAID PROVISIONS IN THEIR SUBMISSION.

Questions:

1. Is redundant power required on ALL switches, including Access Layer / IDF?

• Yes

2. Is stackablility required on access layer / IDF switches?

• Yes

3. Is there a minimum speed requested for Fiber Interconnect, i.e. 1GB, 10GB?

• 10GB

4. What standard is the current fiber optic network i.e. Single Mode, Multi Mode, OM3/4 etc.?

• Single Mode

5. Does the current access point cabling meet mGig standard? i.e. CAT5e for 2.5G, CAT6/6A for 5G, CAT6 up to 55 meters for 10G, CAT6A/7 for 10G.

• Currently Cat 6 is our cabling standard, while at our new Ball High School uses Corning fiber to the edge solution, with Cat 6a cabling to the end point.

End of Addendum

Should you have any additional questions please do not hesitate to contact me via email at anaescobar@gisd.org.

Ana Escobar Ana Escobar Date Purchasing Coordinator

Proposer Date