ESBD_376379_1727725938730_760A1.1 Addendum 1.pdf
PDF 257 KB Posted
- Attached to
- Skid Steer Loaders
- Solicitation number
- 304T-25-760A1.1
- Issued by
- Texas
About this file
This document is an Addendum for Invitation for Bids (IFB) No. 304T-25-760A1.1 issued by the Statewide Procurement Division (SPD), a division of the Texas Comptroller of Public Accounts (CPA), for Skid Steer Loaders. The purpose of this Addendum is to extend the response due date from October 7, 2024 to October 21, 2024, and to make changes to various technical specifications in Attachment G, including adjustments to lift breakout force, transmission and drive, hydraulics, and tires. The Addendum also provides responses to several questions from potential bidders.
The IFB is for a statewide contract, with the Texas Department of Transportation being a major customer for these items. The Addendum outlines the specific changes made to the technical specifications, which appear to be in response to feedback from potential vendors. Pricing terms, set-asides, and funding details are not provided in the Addendum, but can likely be found in the original IFB document.
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statewide Procurement Division
IFB NO. 304T-25-760A1.1 ADDENDUM NO. 1
CONTRACT SPECIALIST: Hadley Lowery, CTCD, CTCM
PURPOSE OF ADDENDUM
The purpose of this Addendum is to extend the response due date, alter Attachment G, and provide a response to questions.
CHANGE RESPONSE DUE DATE:
From: October 7, 2024
To: October 21, 2024
ATTACHMENT G CHANGES:
1. Attachment G, Section B.2, 2.4, Loader, Pneumatic-Tired, Skid Steer Type, Lift Breakout Force:
From:
2.4 Lift Breakout Force: Minimum 7,000 Pounds
To:
2.4 Lift Breakout Force: Minimum 6,300 Pounds
2. Attachment G, Section B.2, 4., Loader, Pneumatic-Tired, Skid Steer Type, Transmission and Drive:
From:
TRANSMISSION AND DRIVE: Unit shall be equipped with a hydrostatic transmission and four-wheel hydrostatic drive.
4.1 Transmission shall prove infinitely variable forward and reverse speeds from:
4.1.1 Maximum Speed in Low Range: Maximum 4.0 mph
4.1.2 Minimum Speed in High Range: Minimum 10.7 mph
To:
TRANSMISSION AND DRIVE: Unit shall be equipped with a hydrostatic transmission and four-wheel hydrostatic drive.
4.1 Transmission shall prove infinitely variable forward and reverse speeds from:
4.1.1 Maximum Speed in Low Range: Maximum 4.0 mph
4.1.2 Minimum Speed in High Range: Minimum 9.6 mph
3. Attachment G, Section B.2, 5., Loader, Pneumatic-Tired, Skid Steer Type, Hydraulics:
5.2 Auxiliary high-flow circuit providing a minimum 36 GPM at rated engine RPM, to power attachments such as cold planers and trenchers.
5.2 Auxiliary high-flow circuit providing a minimum 34 GPM at rated engine RPM, to power
4. Attachment G, Section B.2, 8, Loader, Pneumatic-Tired, Skid Steer Type, Tires:
8. TIRES: 14-17.5 12 PR
8. TIRES: 14-17.5 12 PR or 12 x 16.5 or Customer approved equal
5. Attachment G, Section B.2, 12., Loader, Pneumatic-Tired, Skid Steer Type, Safety and Special
Equipment:
From:
12.10 An auxiliary hydraulic tool circuit that is powered by the unit's central hydraulic system. System shall be located at the front of the unit, complete with all necessary fittings, hoses, and related components to power hydraulic attachments such as a hammer, earth auger, backhoe, and other hydraulically operated attachments. The central hydraulic system shall also have an auxiliary high-flow circuit providing a minimum 36 GPM at rated engine RPM, to power attachments such as cold planers.
To:
12.10 An auxiliary hydraulic tool circuit that is powered by the unit's central hydraulic system. System shall be located at the front of the unit, complete with all necessary fittings, hoses, and related components to power hydraulic attachments such as a hammer, earth auger, backhoe, and other hydraulically operated attachments. The central hydraulic system shall also have an auxiliary high-flow circuit providing a minimum 34 GPM at rated engine RPM, to power attachments such as cold planers.
6. Attachment G, Section B.4, 2., Loader, Tracked, Skid Steer Type, General:
2.1 Rated Operating Capacity (ROC)
@ 50% of Tipping Load: Minimum 5,300 Pounds To:
2.1 Rated Operating Capacity (ROC)
@ 50% of Tipping Load: Minimum 5,275 Pounds
7. Attachment G, Section B.4, 2.4, Loader, Tracked, Skid Steer, Lift Breakout Force:
2.4 Lift Breakout Force: Minimum 7,250 Pounds
2.4 Lift Breakout Force: Minimum 6,420 Pounds
8. Attachment G, Section B.4, 4., Loader, Pneumatic-Tired, Skid Steer Type, Transmission and Drive:
From:
TRANSMISSION AND DRIVE: Unit shall be equipped with a hydrostatic transmission and four-wheel hydrostatic drive.
4.1 Transmission shall prove infinitely variable forward and reverse speeds from:
4.1.1 Maximum Speed in Low Range: Maximum 5.0 mph
4.1.2 Minimum Speed in High Range: Minimum 7.8 mph
To:
TRANSMISSION AND DRIVE: Unit shall be equipped with a hydrostatic transmission and four-wheel hydrostatic drive.
4.1 Transmission shall prove infinitely variable forward and reverse speeds from:
4.1.1 Maximum Speed in Low Range: Maximum 5.0 mph
4.1.2 Minimum Speed in High Range: Minimum 7.8 mph
9. Attachment G, Section B.4, 5., Loader, Tracked, Skid Steer Type, Hydraulics:
5.2 Auxiliary high-flow circuit providing a minimum 36.6 GPM at rated engine RPM, to power attachments such as cold planers and trenchers.
To:
5.2 Auxiliary high-flow circuit providing a minimum 34 GPM at rated engine RPM, to power
10. Attachment G, Section B.4, 12., Loader, Tracked, Skid Steer Type, Safety and Special Equipment:
12.8. An auxiliary hydraulic tool circuit that is powered by the unit's central hydraulic system. System shall be located at the front of the unit, complete with all necessary fittings, hoses, and related components to power hydraulic attachments such as a hammer, earth auger, backhoe, and other hydraulically operated attachments.
The central hydraulic system shall also have an auxiliary high-flow circuit providing a minimum
36.6 GPM at rated engine RPM, to power attachments such as cold planers and trenchers.
Auxiliary/auxiliary high-flow hydraulic tool circuit(s) shall include, but not be limited to, the following:
12.8. An auxiliary hydraulic tool circuit that is powered by the unit's central hydraulic system. System shall be located at the front of the unit, complete with all necessary fittings, hoses, and related components to power hydraulic attachments such as a hammer, earth auger, backhoe, and other hydraulically operated attachments.
The central hydraulic system shall also have an auxiliary high-flow circuit providing a minimum 34 GPM at rated engine RPM, to power attachments such as cold planers and trenchers.
Auxiliary/auxiliary high-flow hydraulic tool circuit(s) shall include, but not be limited to, the following:
QUESTIONS AND ANSWERS: Reference Page 5 of this Addendum
THIS ADDENDUM SHALL BE ATTACHED TO AND FORM A PART OF THE REFERENCED IFB
AND THE CONTRACT.
RESPONDENT MUST ACKNOWLEDGE RECEIPT OF THIS ADDENDUM, BY SIGNING AND
RETURNING WITH RESPONSE. FAILURE TO SUBMIT THE SIGNED ADDENDUM MAY
DISQUALIFY THE RESPONSE.
RESPONDENT COMPANY NAME AUTHORIZED REPRESENTATIVE SIGNATURE
AUTHORIZED REPRESENTATIVE PRINTED
NAME
Questions and Answers IFB No. 304T-25-760A1.1
Question No.
Question Answer
Who, how, where do I demo or propose these units to the state? Our (model name) matches your specs almost perfectly.
There is no demo required to bid the contract. However, unit must meet all stated specifications. Reference Attachment G - Specifications and Requirements.
Reference Part A Sections A.16 and A.17 for more information on the submission process.
Could you please tell me how many skid steers and attachments you are requesting?
Reference Part A Section A.7.4 and the “Pneumatic Skid Steer” and “Tracked Skid Steer” tabs in the Mandatory Price Sheet for more information.
I know these are closed bids, but how would you like them submitted to yourself?
Reference Part A Sections A.16 and A.17 for more information on the submission process.
I would like to request a bid extension till 10/18/24 to gather data and pricing.
Response due date changed to 10/21/2024. Reference addendum 1, page 1.
Under section B.2, 2.1, would an lift breakout force of 6,349 lbs. be acceptable?
B.2.2.4, lift breakout force minimum changed to 6,300. Reference addendum 1, page 1.
Under section B.2, 2.6, I would like to have this spec removed since this is a spec that our manufacturer does not publish.
Denied, this will remain as a specification.
Under section B.2, 4.1.1, would a maximum low range speed of 6.6 mph be acceptable?
This specification has been removed. Reference addendum 1, page 1.
Under section B.2, 4.1.2, would a minimum high range speed of 9.6 mph be acceptable?
B.2.4.1.2, minimum speed in high range changed to 9.6 mph. Reference addendum 1, page 1.
Under section B.2, 5.2 and 12.10, would a minimum of 34 GPM be acceptable?
B.2.5.2 and B.2.12.10, GPM minimum changed to 34 GPM. Reference addendum 1, page 2.
Specifications and Requirements, Page 8, #8 – Tires: Would Heavy or Severe Duty 12X16.5 tires be acceptable, provided the machine meets all performance and operational specifications?
B.2.8, tires changed to 14-17.5 12 PR or 12 x 16.5 or Customer approved equal.
Reference addendum 1, page 2.
Specifications and Requirements, Page 15, 2.1 – Rated Operating Capacity (ROC) @ 50% of Tipping Load: Could the requirement be modified to 5,275 pounds, which reflects 50% of the tipping load (as per ISO 14397-1) of 10,550 pounds? This would be in line with specification 2.2.
B.4.2.1, Rated Operating Capacity minimum changed to 5,275 pounds.
Reference addendum 1, page 2.
Under section B.4, 2.4, would a lift breakout force of 6,422 lbs. be acceptable?
B.4.2.4, lift breakout force minimum changed to 6,420 pounds. Reference addendum 1, page 3.
Under section B.4, 2.4, I would like the have this spec removed since this is a spec that our manufacturer does not publish.
Denied, this will remain as a specification.
Under section B.4, 4.1.1, would a maximum low range speed of 5.2 mph be acceptable?
This specification has been removed. Reference addendum 1, page 3.
Under section B.4, 5.2 and 12.8, would a minimum of 34 GPM be acceptable?
B.4.5.2 and B.4.12.8, GPM minimum changed to 34 GPM. Reference addendum 1, pages 3-4.
Specifications and Requirements, Pages 10 and 18, #13 – LED Warning Light: Would it be permissible to install strobe or beacon lights directly on the ROPS (Roll Over Protection Structure), without the use of brackets?
Denied, this specification will not be changed.
17 What's the certificate holder's address for the Certificate of Insurance Texas Comptroller of Public Accounts, 111 East 17th Street Austin, TX 78774