This document appears to be an enclosure related to a federal contract opportunity for the Department of Veterans Affairs (VA) to replace an inpatient pharmacy robot at the VA Palo Alto Health Care System (VAPAHCS) in Palo Alto, CA.

The key details are: The project involves preparing the site in Building 100, Room E1-120 at VAPAHCS for the installation of a new inpatient pharmacy robot to replace an outdated model currently in use. The solicitation is an SDVOSB set-aside, with the contractor required to follow interim life safety, infection control, and egress plans during construction, as well as coordinate utility shutdowns and "hot work" with the Contracting Officer's Representative. The contractor must work to minimize construction impact on VAPAHCS and pharmacy daily operations, with access to the space provided by pharmacy staff. No new power or data outlets are required, as the new All-in-One (AIO) computers will utilize existing infrastructure.

View the file

Other files

Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OPEN

IP

OP

PHAR

E1-120

PRESC

RCVG

E1-112

OFFICE

E1-110

WAIT

E1-100

IV

WKRM

E1-103

INVEST

DRUGS

E1-105

VAULT/SEC

DISP/FLAM

E1-140

STOCK

CLK

E1-142

TEL/DATA

E1-TC4

ELEC

E1-EC4

HAC

E1-144

POISON

E1-146

ANTE

RM

E1-153

STAIR

E1-SC4

MECH

SHAFT

M-3

MECH

SHAFT

M-6

MECH

SHAFT

M-8

CART

LIFT

E1-SC4

LINEN

CHUTE

LC-1

GOWN

RM

E1-154

HAZARDOUS

RECEIVING

RM

E1-151

HAZARDOUS

CHEMO

BUFFER

E1-152

NON

HAZARDOUS

BUFFER

RM

E1-155

7' - 1"

4' - 5" 4' - 5" 2' - 5" 2' - 5" 2' - 2"

3' - 0"

4' - 0"

3' - 6"

4' - 0"2' - 0" 2' - 0" 7' - 5"

2' - 5"

6' - 7"

10' - 6"

1' - 11"

3' - 6"

24' - 0" 23' - 8"

24' - 0"

24' - 0"

10' - 1"

8' - 3"

5' - 8"

12' - 3"

4' - 6"

4' - 6"

12' - 1"5' - 0"

2' - 2"

4' - 7"5' - 3"6' - 8"

10' - 0"

6' - 0"

6' - 0"

2' - 6"

3' - 11"

2' - 9"

1' - 6"

4' - 0"3' - 3"

8' - 3"

5' - 10" 4' - 0" 2' - 3" 6' - 4"

2' - 1"

"1' - 9"

1' - 7"

4' - 10"

1' - 6"

2' - 0"

2' - 0"

1' - 6"

1' - 11"

2' - 10"

" 8' - 4"

0' - 7"

4' - 0"

3' - 2"

3' - 10"

1' - 9"

1' - 10"

2' - 7"

2' - 7"

3' - 6"

4' - 8"

2' - 6"

2' - 8"

3' - 0"

1' - 8"

3' - 4"

2' - 8"

7' - 3"3' - 10"

15' - 8"

2' - 0"

3' - 2" 3' - 1"

"2' - 0"

6' - 9"

2' - 0"

2' - 7" existing pharmacy robot

24' - 0"

11' - 9"

16' - 3"

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

DESIGN DEVELOPMENT

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

DESIGNER OF RECORD

A/E:

STAMPCONSULTANT

7 8 9 10 engineering discipline <EDIT TEXT>:

321 4 5 6

C U s e rs \v h a p a lc h a n c h r\

D e s k to p \P

A D

P H

A R

M A

C Y

\P A

D P

H A

R M

A C

Y E

X

IS

T

IN

G w it h

I n p a ti e n t S e c ti o n .r v t

/1

/2

:4

:2

P

M

A101-F

EXISTING PHARMACY

Revisions: Date:

1/4" = 1'-0"

01 FIRST FLOOR

LEGEND:

INDICATES EXISTING TABLE/ COUNTER. NO NEW TABLE/ COUNTER IS NEEDED. THE AIO COMPUTERS WILL REST ON/ UTILIZE THESE EXISTING TABLES/ COUNTERS. THESE AIO COMPUTERS WILL UTILIZE

EXISTING DATA AND POWER OUTLETS. NO NEW POWER/ DATA OUTLETS NEEDED U.N.O.

INDICATES A NEW 3'-0" x 2'-0" TABLE FOR AIO COMPUTER

INDICATES A NEW POWER/ DATA OUTLET POLE COMING FROM CEILING FOR AIO COMPUTERS

INDICATES PROPOSED LOCATIONS OF THE NEW AIO COMPUTERS (9 TOTAL)

NOTE: OMNICELL WILL INSTALL ALL AIO COMPUTERS INCLUDING THEIR BRACKETS/ SUPPORTS

(E) OMNICELL

CARAOUSEL

(E) OMNICELL

CARAOUSEL

POSSIBLY A NEW

TABLE

PROVIDE:

- (2) (N) ADDITIONAL DATA

JACKS

- (E) POWER AND DATA

PROVIDE:

- (4) (N) DATA JACKS

- (4) (N) POWER JACKS

AIO ATTACHED TO

A BRACKET THAT

IS MOUNTED TO (E)

CAROUSEL

(E) POWER AND

DATA

AIO ATTACHED TO

A BRACKET THAT

IS MOUNTED TO (E)

CAROUSEL

(E) POWER AND

DATA

(E) POWER

AND DATA

(E) POWER

AND DATA

(E) POWER

AND DATA

(E) POWER

AND DATA

PROVIDE:

- (4) (N) DATA JACKS

- (4) (N) POWER JACKS