Enclosure 4 - Attachment 2 - Painting of New 500K Gallon Water Tower _Tank Drawings.pdf

PDF 852 KB Posted

Attached to
419151 Preparation and Painting of 500k Gallon Water Tower
Solicitation number
419151DH
Issued by

View the file

Other files

File Type Posted
Enclosure 4 - Attachment 10 - BSA General Terms and Conditions for Construction and Labor Hour Agreements Rev. 21.0.pdf PDF
Enclosure 4 - Attachment 11 - BSA Supplemental Terms and Conditions Ensuring Adequate COVID-19 Safety Protocols for Federal Contractors.pdf PDF
Enclosure 4 - Attachment 3 - Painting of New 500K Gallon Water Tower _ Electrical Drawings.pdf PDF
Enclosure 3 - AMS-Form-050 Annual Representations and Certifications.pdf PDF
Enclosure 4 - Attachment 8 - Payment Bond Form No. AMS-Form-025.docx DOCX document
Enclosure 4 - Attachment 7 - Performance Bond Form No. AMS-Form-024.docx DOCX document
419151 Water Tower Invitation for Bid.pdf PDF
Enclosure 4 - 419151 Preparation and Painting of The Upton Road Water Tower Draft Contract.docx DOCX document
Enclosure 2 - Bid Sheet.docx DOCX document
Enclosure 1 - Qualification Criteria.docx DOCX document
Enclosure 4 - Attachment 1 - Painting of New 500K Gallon Water Tower _Contract Specifications.pdf PDF
Enclosure 4 - Attachment 4 - Brookhaven National Laboratory Supplier Quality Assurance Requirements (BNL-QA-101).pdf PDF
Enclosure 4 - Attachment 5 - Construction Wage Rate General Decision No. NY20220012.pdf PDF
Enclosure 4 - Attachment 6 - SF-1444.pdf PDF
Enclosure 4 - Attachment 9 - Final Release of Claim Form No. AMS-Form-022.docx DOCX document
Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

architects engineers

538 Broad Hollow Road, 4th Floor East

Melville, NY 11747

631.756.8000 ▪ www.h2m.com

SHEET No.

SHEET TITLE

"ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED

PROFESSIONAL IS ILLEGAL"

REVIEWED BY:DRAWN BY:DESIGNED BY:

PROJECT No: DATE:

CHECKED BY:

CONSULTANTS:

Q

CONTRACT

CLIENT

STATUS

SCALE:

AS SHOWN

DRAWING No.

OF8

/2

/2

:4 :3

P

M C

U s e rs

\c d e lg a tt o \D o c u m e n ts

\B N

L O

C e n tr a l2

P a in tin g C o n tr a c t_ c d e lg a tt o

.r v t

E 001

FINAL BID DOCUMENT

Painting of New 500,000 Gallon Water Tower

Brookhaven

National Laboratory

CJD

AUGUST 2022BNLO1804

CJD / JEK

Upton Road, Upton, New York 11973

LEGENDS AND SCHEDULES

CONTRACT P - PAINTING

A2.2

A2.2

A2.2

A2.2

SCALE

A2.2

- EXISTING FENCE

- EXISTING NATURAL GAS SERVICE

- EXISTING TELEPHONE SERVICE

- EXISTING PRIMARY ELECTRIC SERVICE

- EXISTING OVERHEAD ELECTRIC LINES

- EXISTING ELECTRIC LINES

- EXISTING SEWER SERVICE

X

O/H

PE

E

S

T

G

W - EXISTING WATER SERVICE

- CURB

(SIZE INDICATED ON PLANS)

TITLE

H

GROUND FAULT INDICATORGFI

TIME CLOCK

CABLE TV. PROVIDE 3/4" E.C. W/ DRAG LINE TO AFC & EMPTY BOX

RECESSED IN WALL W/BLANK COVER.

NEMA 4X STAINLESS STEEL JUNCTION BOX WITH GASKETED COVER

DATA. PROVIDE 3/4" E.C. W/ DRAG LINE TO AFC & EMPTY BOX

RECESSED IN WALL W/BLANK COVER.

CONDUIT GOING UP

CONDUIT GOING DOWN

ELECTRICAL PANEL P1, SURFACE; SEE PANEL SCHEDULES.

ELECTRICAL PANEL P1, RECESSED; SEE PANEL SCHEDULES.

D

TV

T

TELEPHONE. PROVIDE 3/4" E.C. W/ DRAG LINE TO AFC & EMPTY BOX

RECESSED IN WALL W/BLANK COVER.

4X

PULL BOX

P1

P1

DUPLEX RECEPTACLE, 120V, 20A; SUBLETTER "C" INDICATES

CEILING MOUNTED

DISCONNECT SWITCH, DS1; SEE DISCONNECT SWITCH SCHEDULE.

MAGNETIC STARTER, S1 ; SEE STARTER SCHEDULE.

TWIST LOCK RECEPTACLE, 120V, 20A, 3 WIRE; UNLESS OTHERWISE

NOTED

SPECIAL PURPOSE OUTLET, 240V, 40A. VERIFY NEMA

CONFIGURATION W.EQUIPMENT MANUFACTURER

DUPLEX RECEPTACLE, 120V, 20A; SUBLETTER "WP" INDICATES WEATHER PROOF. PROVIDE WEATHER-

PROOF IN USE COVERS FOR ALL RECEPTACLES WITH SUBLETTER "WP".

DUPLEX RECEPTACLE, 120V, 20A; FLOOR MOUNTED.

S1

TL

J JUNCTION BOX.

DS1

WP

GFI

C

SIMPLEX RECEPTACLE, 120V, 20A. COORDINATE MOUNTING HEIGHT WITH

MECHANICAL CONTRACTOR TO CLEAR BASEBOARDS

DEDICATED HOMERUN TO PANEL LP1 FOR CIRCUIT No. 35 ONLY.

3 #12 AWG + #12 AWG GND IN 3/4" E.C. CONCEALED IN OR BELOW SLAB

5 #12 AWG + #12 AWG GND IN 3/4" E.C. CONCEALED IN WALL OR CEILING

2 #12 AWG + #12 AWG GND IN 3/4" E.C. CONCEALED IN WALL OR CEILING

LP1-35

PB

PC

TC

PUSH BUTTON

PHOTOCELL

CONTROL CIRCUIT (MIN. 2 #12 AWG IN 3/4" E.C.)

MULTIPLE BRANCH CIRCUITS AS REQUIRED

18" AFF

TO CL UON

FULL VOLTAGE NON-REVERSING STARTER, NEMA SIZE 6.

TRANSFORMER WITH SIZE, PRIMARY & SECONDARY VOLTAGES

ELECTRIC METER AND METER PAN AS PER PSEG REQUIREMENTS

FUSED DISCONNECT SWITCH DS2, FUSED AT 40 AMPS, 3 POLES

AS NOTED.

MOTOR, NUMBER INDICATES HORSEPOWER

CURRENT TRANSFORMERS

DISCONNECT SWITCH DS1, 100A, 2 POLE

(SEE DISCONNECT SWITCH SCHEDULE)

(SEE DISCONNECT SWITCH SCHEDULE)

FVNR

CTS

FLUSH

FLUSH

M

100/2

DS2

40/3

DS1

UNLESS OTHERWISE NOTED

LINE VOLTAGE THERMOSTAT 120V, 10A

DISTRIBUTION PANEL P1 W/30A, 2 POLE M.C.B.

(SEE DISTRIBUTION PANEL SCHEDULE)

CIRCUIT BREAKER WITH TRIP & POLES AS NOTED

WEATHER PROOF

CENTERLINE

P1

30/2

MCB

T

UON

PSEG

WP

CL

SINGLE POLE SWITCH; "A" INDICATE SWITCH CONTROL

KEYED THREE - WAY SWITCH

SINGLE POLE KEYED SWITCH

THREE - WAY SWITCH

RIGID GALVANIZED STEEL ELECTRICAL CONDUIT

AMERICAN WIRE GUAGE

VOLTS DIRECT CURRENT

VOLTS ALTERNATING CURRENT

MAIN CIRCUIT BREAKER

MAIN LUGS ONLY

VOLT

AMPERE

ABOVE FINISHED GRADE

ABOVE FINISHED CEILING

ABOVE FINISHED FLOOR

TO CL UON

46" AFF

TO CL UON

46" AFF

EC

AWG

VDC

VAC

MCB

MLO

V

46" AFF

TO CL UON

46" AFF

TO CL UON

AMP, A

AFG

AFC

AFF

S

M

GFCI GROUND FAULT CIRCUIT INTERRUPTER

ATS

TRANSFORMERX-FMR

COUNTER TOPCT

UNDER COUNTERUC

PUBLIC SERVICE ELECTRIC AND GAS (LOCAL

ELECTRIC UTILITY)

AUTOMATIC TRANSFER SWITCH (SEE TRANSFER

SWITCH SCHEDULE)

COMBINED DATA AND TELEPHONE. PROVIDE 3/4" E.C. W/ DRAG LINE TO

AFC & EMPTY BOX RECESSED IN WALL WITH BLANK COVER.

FOR MONITOR. J. BOX RECESSED IN WALL W/ BLANK COVER PROVIDE 3/4"

E.C. AND DRAG LINE TO ABOVE FINISHED CEILING.

J. BOX RECESSED IN WALL W/BLANK COVER. PROVIDE 3/4" E.C & DRAG

LINE TO ABOVE FINISHED CEILING. MOUNT 18" AFF, UNLESS OTHERWISE NOTED

FLUSH

FLUSH

FLUSH

FLUSH

QUAD RECEPTACLE, DOUBLE DUPLEX RECEPTACLE, 120V, 20A; COORDINATE MOUNTING

HEIGHT WITH MECHANICAL CONTRACTOR TO CLEAR BASEBOARDS.

DUPLEX RECEPTACLE, 120V, 20A; WITH GROUND FAULT INDICATOR. COORDINATE MOUNTING

HEIGHT WITH MECHANICAL CONTRACTOR TO CLEAR BASEBOARDS.

SECURITY CAMERA BOX. PROVIDE 3/4" E.C. W/ DRAG LINE TO AFC

& EMPTY BOX RECESSED IN WALL W/BLANK COVER.S

TO CL UON

18" AFF

BFC BELOW FINISHED CEILING

SWITCH W/ THERMAL OVERLOAD PROTECTION (CONTRACTOR SHALL COORDINATE

VOLTAGE, PHASE WITH EQUIPMENT)

ELEVATION KEY

DETAIL KEY

ON DWG. #

SEE NOTE #

ROOM DESIGNATION

BUILDING SECTION CUT

WALL SECTION CUT

ELEVATION

REFERENCE

INTERIOR

DRAWING TITLE

COLUMN GRID

ELEVATION LINE

K3

K

T

A

C

SINGLE LINE DIAGRAM LEGEND

SYMBOL DESCRIPTION COMMENTSSYMBOL DESCRIPTION

ELECTRICAL LEGEND

COMMENTS SYMBOL DESCRIPTION COMMENTS

SITE PLAN LEGEND

- NEW ELECTRIC PULL BOX

- NEW PRIMARY ELECTRIC SERVICE

- NEW CABLE SERVICE

- NEW ELECTRIC LINES

PE

E

SYMBOLS LEGEND

S

S

S

S

S

DUPLEX RECEPTACLE, 120V, 20A. COORDINATE MOUNTING HEIGHT WITH

MECHANICAL CONTRACTOR TO CLEAR BASEBOARDS

J

J

J

PS PRESSURE SWITCH

PROPORTIONAL- INTEGRAL-DERIVATIVE SINGLE LOOP

CONTROLLER

TELEPHONE LINE DISCONNECT SWITCH

SOLENOID VALVE

TLDS

PID

LEVEL ELECTRODES

LEVEL TRANSMITTER

LE

LT

MOTOR CONTROLLED VALVE WITH LIMIT SWITCHES

PRESSURE TRANSMITTER

PUMP OR BLOWER MOTOR

FLOW SWITCH

FLOW TRANSMITTER

PT

FT

FS

FLOW METER

LIMIT SWITCH

M

ZS

ELECTRICAL CONTROL LEGEND

SYMBOL DESCRIPTION COMMENTS

HIGH WATER LEVEL SENSORHW

SV

LEAK SWITCHLS

PRESSURE TRANSMITTERZT

DIFFERENTIAL PRESSURE TRANSMITTERDPT

LEVEL FLOATLF

GROUNDGND

DIFFERENTIAL PRESSURE SWITCHDPS

TO CL UON

48" AFF

TO CL UON

48" AFF

TO CL UON

48" AFF

PB NEMA 4X STAINLESS STEEL PUSH BUTTON4X

20A

120V 3W

MCGRAW-EDISON

LUMARK

LIGHTING FIXTURE SCHEDULE

TYPE MFG. VOLTAGE

F1

F2

MODEL

NO.

IST-E02-LED-E1-BL4-BK-P-BBB-120

LDWP-GL-6B-MT

LAMPS

NO. PER

FIXTURE

TYPE WATTS MOUNTING REMARKS

MOUNTING

HEIGHT

LED

LED

UNV

SURFACE

SURFACE

0'-6" ABOVE

DOOR

REFER TO

E 200

LUMARK LDWP-GL-6B-MT-EMLED-CD 1 LED 46 UNV SURFACE

REFER TO

E 200F1A

W/ EMERGENCY BATTERY

PACK

W/ EMERGENCY BATTERY

PACK

PC INTERMATIC K-4221C SURFACE 7'-6" A.F.G

F3 HALCO VPT-20-4K-U 1 LED 20 UNV SURFACE

REFER TO

E 200

WALL MOUNT

MARK DATE DESCRIPTION

LT

FS

T

PS

E 200

E 200

TO NEW RTU

PP1-9

WP

WP

WPGFCI

PP1-3

PP1-3

PP1-3

A

B

A

B

PP1-5

PP1-3

WP

EXISTING STAINLESS

STEEL CHANNEL RACK

NEW RTU PANEL (NOTES

1,2)

NEW TANK LEVEL

TRANSMITTER IN

SAMPLE STATION

NEW HEAT TRACE CABLE

CONTROLLER IN SAMPLE

STATION, NOTE 3

MOUNTED AT 48" A.F.F.,

TYP. FOR 3

EXISTING POWER

PANEL 'PP1'

NOTE 6

0°

90°

180°

270°

E 500T 500

T 500

NEW OVERFLOW FLOW

SWITCH ON FACTORY

INSTALLED TAP ON TEE

TO RTU

T 500

PP1-14

TO NEW RTU

CAT 6 CABLE IN 3/4" E.C.

NEW TANK

TEMPERATURE

TRANSMITTER

TO RTU

PP1-11

PP1-8

PP1-4

PP1-10

PP1-12

NEW TANK PRESSURE

TRANSMITTER IN

SAMPLE STATION

SHIELDED TWISTED

PAIR IN 3/4" E.C.

EXISTING 4" FIBER OPTIC

CONDUIT PENETRATION AND

FIBER OPTIC COIL (NOTE 7)

NETWORK RACK,

NOTE 7 T 100

PP1-6

GFCI

WP

NEW RECEPTACLE. MOUNT TO

EXISTING BRACKET, 1'-6" ABOVE

LOWER PLATFORM.

90° 270°

0°

180°

PP1-6

WP

NEW RECEPTACLE. MOUNT TO

EXISTING BRACKET 1'-6" ABOVE

UPPER PLATFORM.

architects engineers

538 Broad Hollow Road, 4th Floor East

Melville, NY 11747

631.756.8000 ▪ www.h2m.com

SHEET No.

SHEET TITLE

"ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED

PROFESSIONAL IS ILLEGAL"

REVIEWED BY:DRAWN BY:DESIGNED BY:

PROJECT No: DATE:

CHECKED BY:

CONSULTANTS:

Q

CONTRACT

CLIENT

STATUS

SCALE:

AS SHOWN

DRAWING No.

OF8

/2

/2

:4 :3

P

M C

U s e rs

\c d e lg a tt o \D o c u m e n ts

\B N

L O

C e n tr a l2

P a in tin g C o n tr a c t_ c d e lg a tt o

.r v t

E 100

FINAL BID DOCUMENT

Painting of New 500,000 Gallon Water Tower

Brookhaven

National Laboratory

CJD

AUGUST 2022BNLO1804

CJD/MGL/JEK

Upton Road, Upton, New York 11973

TANK ELECTRICAL PLAN

CONTRACT P - PAINTING

SCALE: 1/4" = 1'-0"

Electrical Tank Floor Plan

SCALE: 1/4" = 1'-0"

Electrical Lower Platform Floor Plan

SCALE: 1/4" = 1'-0"

Electrical Upper Platform Floor Plan

ELECTRICAL NOTES:

1. CONTRACTOR SHALL PROVIDE TWO (2) NEW 300W STRIP HEATER (CALORITECH FS SERIES STRIP HEATER OR APPROVED EQUAL) AND A DIN RAIL MOUNTED 120V RATED THERMOSTAT INSIDE THE NEW

RTU ENCLOSURE.

2. CONTRACTOR SHALL PROVIDE ALL HARDWARE AND ACCESSORIES AS REQUIRED TO MOUNT ITEM

INDICATED ON THE EXISTING STAINLESS STEEL CHANNEL RACK.

3. CONTRACTOR SHALL INTERFACE HEAT TRACE CABLE "ON" STATUS WITH NEW RTU.

4. ALL RECEPTACLES INDICATED TO BE ON THE SAME CIRCUIT AS "GFCI" RECEPTACLES SHALL BE

CONNECTED TO LOAD SIDE OF THE "GFCI" RECEPTACLE SO THAT ALL RECEPTACLES ON THE CIRCUIT

ARE PROVIDED WITH GFCI PROTECTION.

5. EXISTING ELECTRICAL MOUNTING BRACKETS AT BASE OF TANK ARE LOCATED APPROXIMATELY 12' - 3" A.F.F.

6. CONTRACTOR SHALL PROVIDE AND INSTALL WIRE AND CONDUIT BETWEEN THE SAMPLING STATION AND THE RTU PANEL FOR EACH FOLLOWING DEVICES INSTALLED WITHIN THE SAMPLING STATION:

A. LEVEL TRANSMITTER (SHIELDED TWISTED PAIR CABLE IN 3/4" E.C.)

B. PRESSURE SWITCH (4 #14 AWG IN 3/4" E.C.)

C. HEAT TRACE (CAT-6 CABLE IN 3/4" E.C.)

D. TEMPERATURE TRANSMITTER (4 #14 AWG IN 3/4" E.C.)

7. CONTRACTOR SHALL PROVIDE ALL HARDWARE AND ACCESSORIES AS REQUIRED TO EXTEND EXISTING 4" CONDUIT PENETRATION INDICATED TO THE NETWORK RACK. CONTRACTOR SHALL THEN ROUTE THE EXISTING FIBER OPTIC CABLE FROM THE FIBER OPTIC CONDUIT PENETRATION, VIA THE NEW 4" CONDUIT, TO THE NETWORK RACK INDICATED. FIBER OPTIC CABLE SHALL BE COILED WITHIN THE

NETWORK RACK WITH 5' OF SLACK.

N

PROJECT

NORTH

N

PROJECT

NORTH

N

PROJECT

NORTH

1 07/2022 BNL Review Revisions

Finished Grade -0' - 6"

Overflow Elevation 127' - 1 13/16"

Low Water Elevation 89' - 7 13/16"

Lower Platform ± 28' - 5 1/4"

Upper Platform ± 74' - 9"

Top of Access Tube Cover 134' - 5 3/4"

LIGHT FIXTURE ABOVE

DOOR, TYP. OF 2 (NOTE 3)

MOUNT PHOTOCELL AT 7'-6"

A.F.G., ON SIDE OF THE

ENTRANCE AND AWAY

FROM THE OUTDOOR LIGHT

FIXTURE

LOCATE APPROXIMATELY 6'-0"

ABOVE UPPER PLATFORM

NEW MOUNT RECEPTACLE.

MOUNT TO EXISTING

BRACKET, 18" BELOW DRY

RISER HATCH

F2

F1

B

F1A

B

F1A

B

F3

B

WP

GFCI

PP1-7

ELEV. 110.13'

ELEV. 199.15'

ELEV. 237.65'

First Floor 0' - 0"

ELEV. 110.63'

Overall Height 137' - 9 1/2"

APPROXIMATE LOCATION OF

LIGHT SWITCHES, REFER TO

DRAWING E 100 FOR

ADDITIONAL INFORMATION

Finished Grade -0' - 6"

Overflow Elevation 127' - 1 13/16"

Low Water Elevation 89' - 7 13/16"

Lower Platform ± 28' - 5 1/4"

Upper Platform ± 74' - 9"

Top of Access Tube Cover 134' - 5 3/4"

FIXTURE LOCATED AT TOP OF

ACCESS TUBE (NOTE 2)

MOUNT FIXTURE TO EXISTING

BRACKET 12'-0" A.F.F., TYP. FOR 4

(TWO (2) F1A WITH BATTERY

BACKUP AND TWO (2) F1

FIXTURES EVENLY SPACED)

F1A A F1A A

F3A

B

F3A

B

NOTE 2

ELEV. 110.13'

ELEV. 199.15'

ELEV. 237.65'

F3A

B

NOTE 2

First Floor 0' - 0"

ELEV. 110.63'

Overall Height 137' - 9 1/2" architects engineers

538 Broad Hollow Road, 4th Floor East

Melville, NY 11747

631.756.8000 ▪ www.h2m.com

SHEET No.

SHEET TITLE

"ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED

PROFESSIONAL IS ILLEGAL"

REVIEWED BY:DRAWN BY:DESIGNED BY:

PROJECT No: DATE:

CHECKED BY:

CONSULTANTS:

Q

CONTRACT

CLIENT

STATUS

SCALE:

AS SHOWN

DRAWING No.

OF8

/2

/2

:4 :3

P

M C

U s e rs

\c d e lg a tt o \D o c u m e n ts

\B N

L O

C e n tr a l2

P a in tin g C o n tr a c t_ c d e lg a tt o

.r v t

E 200

FINAL BID DOCUMENT

Painting of New 500,000 Gallon Water Tower

Brookhaven

National Laboratory

CJD

AUGUST 2022BNLO1804

MGL / JEK

Upton Road, Upton, New York 11973

TANK ELEVATION ELECTRICAL

PLAN

CONTRACT P - PAINTING

SCALE: 1/8" = 1'-0"

Tank Section View 2

SCALE: 1/8" = 1'-0"

Tank Section View 1

ELECTRICAL NOTES:

1. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL REQUIRED MOUNTING BRACKETS FOR

LIGHTING, SWITCHES, RECEPTACLES, AND ASSOCIATED CONDUIT AND WIRING.

2. MOUNT ALL NEW FIXTURES, SWITCHES, RECEPTACLES, ETC. TO EXISTING MOUNTING BRACKETS.

PROVIDE ALL REQUIRED TAPS, HOLES, ETC. FOR ALL REQUIRED MOUNTING PRIOR TO BLASTING AND

PAINTING OPERATIONS.

LIGHTING GENERAL NOTES:

G1. CONTRACTOR SHALL PROVIDE 12" OF FLEXIBLE LIQUID-TIGHT CONDUIT FOR ALL RIGID

GALVANIZED-STEEL CONDUIT RUNS EXCEEDING 30'-0" AND FOR ALL CONNECTIONS TO ALL

DEVICES (NOT LIMITED TO LOCATIONS SHOWN ON DRAWINGS) TO ALLOW FOR NORMAL TANK

DEFLECTION. PROVIDE "DRIP LOOP" OF FLEXIBLE CONDUIT WHERE APPLICABLE, NO

LONGER THAN 36".

G2. PROVIDE ALL REQUIRED WIRING NECESSARY BETWEEN SWITCHES AND LIGHTING FIXTURES

FOR COMPLETE LIGHTING CONTROL. PROVIDE 2 #10 AWG + #10 AWG GND FOR ALL NEW

LIGHTING CIRCUITS.

G3. FIXTURES INDICATED WITH CIRCUIT DESIGNATIONS SHALL BE CONNECTED TO LINE SIDE OF

CIRCUIT.

G4. FIXTURES INDICATED WITH CIRCUIT DESIGNATIONS SHALL BE CONNECTED TO SWITCH WITH

CORRESPONDING LETTER DESIGNATION.

G5. PROVIDE AND INSTALL DEDICATED NEUTRAL FOR EACH CIRCUIT. CONTRACTOR IS NOT

PERMITTED TO USE COMMON NEUTRALS.

G6. PROVIDE BOX AND ACCESSORIES AS PER MANUFACTURER'S RECOMMENDATION FOR ALL

SWITCHES.

G7. VERIFY EXACT LOCATIONS OF FIXTURES IN CONJUNCTION WITH EXISTING MOUNTING

BRACKETS.

G8. WIRING FOR EMERGENCY BALLAST IS NOT SHOWN ON PLANS. FIXTURES WITH EMERGENCY

BALLASTS SHALL BE PROVIDED WITH AN UNSWITCHED POWER FEED FROM CIRCUIT FEEDING

LIGHT FIXTURE.

G9. CONTRACTOR SHALL USE SILICONE WATER PROOF SEALANT TO SEAL TOP, LEFT AND RIGHT

EDGES OF LIGHT FIXTURES TO WALL TO PREVENT MOISTURE FORM ACCUMULATING BEHIND

FIXTURE. BOTTOM EDGE SHALL BE LEFT UNSEALED FOR DRAINAGE. COLOR OF SILICONE

SHALL MATCH EITHER WALL COLOR OR FIXTURE COLOR (TYP. OF ALL WALL MOUNTED

FIXTURES).

G10. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL REQUIRED MOUNTING

BRACKETS AT ALL LOCATIONS IN ORDER TO MOUNT LIGHT FIXTURES PERPENDICULAR TO

THE FINISHED FLOOR.

1 07/2022 BNL Review Revisions

NEW RTU PANEL

EXISTING

PANEL PP1

EXISTING 12 GA. 1-1/2" X

1-7/8" STAINLESS STEEL

CHANNEL (TYP.), NOTE 1

NOTES:

1. NEW CHANNEL SUPPORT FOR NEW RTU PANEL AND PANEL PP1 SHALL BE MOUNTED TO MOUNTING BRACKETS PRE-FABRICATED BY THE TANK MANUFACTURER/INSTALLER. CONTRACTOR SHALL COORDINATE WITH TANK

INSTALLER AND ENGINEER FOR EXACT LOCATION OF MOUNTING BRACKETS.

SCALE:

RTU and Electrical Panel Mounting Detail

2 NTS

EXISTING SWITCH

FOR EXISTING

HELICOPTER

LIGHTING

EXISTING

STAINLESS STEEL

BACKPLATE

EXISTING

RECEPTACLE WITH

WEATHERPROOF

IN-USE COVER AND

BOX

SCALE:

Panel Wiring Schedule

3 NTS

3 WIRES + GROUND PROVIDE

ADDITIONAL WIRES AS NECESSARY

FOR 3-WAY SWITCHING.

LIGHT FIXTURE WITH EMERGENCY

BALLAST

LED DRIVER

EMERGENCY

BALLAST

HOT WIRE (LOAD SIDE OF SWITCH)

HOT WIRE (LINE SIDE OF SWITCH)

LIGHT SWITCH (ES)

TEST SWITCH

LED

N

L

SCALE:

Typical Detail of Light Fixture with Emergency Ballast

1 NTS

E 500.00

ELECTRICAL DETAILS

CJD / AMT MGL / JEK

MARK DATE DESCRIPTION

CLIENT

X:

\B

NL

O

(B ro ok ha ve n N ati on al La

b) \B

NL

O1

4 -

N ew

0K

E lev ate d S tor ag e T an k\0 2-

BI

M-

CA

DD

\C on

-d oc s\e lec

\E

0.d wg

La st

Mo dif ied : A ug

, 2

2 - 5:

pm

P lot ted on

: A ug

, 2

2 -

5:

pm B y c de lga tto

CONSULTANTS:

Brookhaven

National Laboratory

SHEET No.

SHEET TITLE

CONTRACT

STATUS

OF

DESIGNED BY: DRAWN BY:

Q

PROJECT No.:

BNLO1804

DATE:

AUGUST 2022

CHECKED BY: REVIEWED BY:

SCALE:

AS SHOWN

DRAWING No.

Painting of New 500,000 Gallon

Water Tower architects engineers

538 Broad Hollow Road, 4th Floor East

Melville, NY 11747

631.756.8000 ▪ www.h2m.com

"ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL IS ILLEGAL"

CONTRACT P - PAINTING

FINAL BID DOCUMENT

Upton Road, Upton, New York 11973

1 07/2022 BNL Review Revisions2. PROVIDE AND INSTALL A CONVENIENCE DATA JACK AND POWER RECEPTACLE ON THE

FACE OF THE RTU ENCLOSURE.

CONVENIENCE DATA

JACK AND POWER

RECEPTACLE (NOTE 2)

TANK LOW TEMPERATURE

THERMOSTAT

Phase

Options Mains Rating

Panel Wiring Schedule (1-Phase)

Panelboard

Panel Type Manufacturer

NEMA Type Enclosure

Voltage Mains Mounting

PP1

SIEMENS

P1 3R

SURFACE

100A MCB

120/240 10,000

Note

Wire1

125A

AIC Rating

A

BLOAD DESCRIPTION BREAKER

OPTION

TRIP

AMPS

AND

POLES

CONNECTED LOAD

VOLT AMPERES

ØA ØB CI

RC

. N o.

CI

RC

. N o.

VOLT AMPERES

CONNECTED LOADTRIP

AMPS

AND

POLES

TRIP

AMPS

AND

POLES

BREAKER

OPTION LOAD DESCRIPTION

GROUND FLOOR RECEPTACLES

20A/1PFIRST FLOOR LIGHTS

HELICOPTER LIGHTING

TOP OF HATCH RECEPTACLE

HEAT TRACE #1

RTU PANEL HEATER #2

20A/1P 20A/1P 20A/1P 30A/1P 20A/1P

20A/1P 20A/1P 20A/1P 20A/1P

2.2

20A/1P 20A/1P

RTU PANEL

TOWER LIGHTS

UPPER/LOWER PLATFORM RECEPTACLE

NETWORK ENCLOSURE

RTU PANEL HEATER #1

NETWORK ENCLOSURE

(All Phases to be balanced to within 7% using Actual Load Totals.)

ØB

Total

2.3 4.4

Connected Totals: ØA KVA

LO - Handle lock-off device

GFCI - Ground Fault Circuit Interrupter HACR - Heating, A/C & Refrigeration

SF - Subfeed PA - Handle Padlock Attachment

TC - Time Clock Control

AUX - Auxiliary Contacts

ST - Shunt Trip Type

Amperes18.3

Breaker Options:

AS - Powerlink AS Breaker

KVA

KVA

ØA ØB

13 14SPARE 20A/1P 20A/1P SAMPLE STATION CABINET HEATERS_ 200

15 16SPARE 20A/1P 20A/1P SPARE_ _

17 18SPARE 20A/1P 20A/1P SPARE_ _

GFCI

HACR

HACR

NOTE:

1. PROVIDE A TYPED CIRCUIT DIRECTORY IN ACCORDANCE WITH NEC SECTIONS 110.22

AND 408.4. CIRCUITS INCLUDING SPARES SHALL BE LABELED WITH DETAILED

INFORMATION DESCRIBING THE SWITCHES FUNCTION AND EQUIPMENT LOCATION.

3. CONTRACTOR SHALL REMOVE, STORE, PROTECT, REINSTALL, ETC. ALL EXISTING ELECTRICAL

EQUIPMENT AS REQUIRED FOR SPECIFIED SURFACE PREPARATION AND PAINTING.

2 08/2022 BNL Review Revisions 2

3'- 6"

4'- 0"

NOTE:

1. CONCRETE TO ACHIEVE 4000 PSI STRENGTH AT 28 DAYS.

2. BOLLARD SURFACE POWDER COATED BLACK.

4"

CROWN TO

SHED WATER

18"Ø CONC.

FOOTING

COVER PIPE WITH 4.5" YELLOW

BOLLARD COVER BY POSTGUARD

PRODUCTS OR APPROVED EQUAL

(323613.00 H2MX1)-R4

Steel Bollard - 4" Diameter

SCALE: NTS

1" WHITE REFLECTIVE BANDS

FILL PIPE WITH CONCRETE.

CROWN TO SHED WATER

4"Ø GALVANIZED STEEL PIPE

Sheets
E 001 - LEGENDS AND SCHEDULES
E 100 - TANK ELECTRICAL PLAN
E 200 - TANK ELEVATION ELECTRICAL PLAN
E 500 - ELECTRICAL DETAILS

File details come from the government source that posted it. Updated .