Electrical CTAE Media

2 MB Posted

Attached to
Data Cabling for New Groves K-12 School (ERATE)
Solicitation number
RFP22-28
Issued by
Chatham County, Georgia

About this file

This file consists of electrical construction drawings and site plans for the Electrical CTAE Media Building component of a new K-12 multi-school project undertaken by the Savannah-Chatham County Public School System (SCCPSS) in Georgia. The drawings, prepared by LS3P Associates Ltd. and dated October 9, 2020, with revisions through February 18, 2021, detail the electrical infrastructure requirements for the Media Building/CTAE facility, including site electrical plans (E-002, E-003), first and second floor power plans (E-201, E-202), and enlarged detailed plans (E-500). The project encompasses multiple buildings with varying finished floor elevations: the Fieldhouse (24.20), Multi-Media Building (24.00), K-12 Building (23.00), Baseball Concessions (23.75), and various other concession facilities. The electrical site plan specifies underground conduit routing (minimum 3/4" Schedule 40 PVC), pad-mounted utility company transformers, pull boxes, and comprehensive utility coordination requirements, including provisions for data, security, intercom, and fire alarm connections. The drawings establish specific technical standards such as distance limitations for 120-volt, 20-ampere branch circuits, with conductor sizing requirements for circuit lengths exceeding 70, 115, and 180 feet.

The specifications detail critical electrical infrastructure components including utility transformer pads with minimum clearances of 10 feet from walkways and 14 feet from doors, water-tight in-grade floor boxes rated for vehicle traffic, and extensive telecommunications provisions including main grounding busbars, cable trays, and metallic conduit bonding systems. The project incorporates multiple electrical distribution systems including panel boards (MSB-M, ELM1, ELM2), automatic transfer switches (ATS-EHM1, ATS-ELM1), and fire alarm control panel circuits with dedicated breaker lockouts and red nameplates. Underground utility work requires coordination with the utility company for transformer furnishing and installation, with the contractor responsible for all utility coordination, underground utility verification through the Underground Utility Center, and staking of existing utilities prior to rough-in. The drawings indicate that GA Power is responsible for parking lot lighting supply and installation as well as removal and relocation of existing poles, guy wires, transformers, and associated electrical utility structures, with contractors coordinating all schedules and conflicts.

Text of this file

106 138

154 130

130 114

146154

138130

138 130

178210

106 106

106106

130 130

2955 2955

138138

12 12

36 3636

2 48

FIELDHOUSE

FFE: 24.20

MULTI-MEDIA

BUILDING

FFE: 24.00

K-12

BUILDING

FFE: 23.00

BASEBALL

CONC & REST

CONCESSIONS

FFE: 23.75

CONCESSIONS

FFE:

23.80

CONCESSIONS

FFE:

23.84

D OWN

D OWN

D O W N

D O W N

D O W N

D O W N

2 00 025 0432 422n1 n1

X X

E-003

UTIL CO.

XFMR

GEN-F

STADIUM FIELD HOUSE

AND POLICE ANNEX

BASEBALL

YOUTH BASEBALL

SOFTBALL

MULTI-PURPOSE

COMPETITION FIELD

TENNIS

COURTS

FEILD CONCESSION BUILDING

SOCCER FIELD

MULTI-MEDIA

CTAE BLDG

NEW K-12

MULTI-SCHOOL

GEN-MEDIA

UTILITY CO.

XFMR-MEDIA

MSB-M

CHECKED BY:

DRAWN BY:

DATE:

PROJECT:

REVISIONS:

MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS

A

2 3 4 5 6

B

C

D

E

COPYRIGHT 2019 ALL RIGHTS RESERVED

PRINTED OR ELECTRONIC DRAWINGS AND

DOCUMENTATION MAY NOT BE REPRODUCED

IN ANY FORM WITHOUT WRITTEN PERMISSION

FROM LS3P ASSOCIATES LTD.

WWW.LS3P.COM

SAVANNAH, GEORGIA 31401

TEL. 912.695.2111 FAX 912.298.0206

321 WEST CONGRESS STREET SUITE 301

/1

/2

:5 :2

P

M

B

IM

/S C

C P

S S

N e w

K -1

M u lt i- S c h o o l/ E

L E

C G ro v e s K

C

T A

E v .r v t

5201-192070

10/09/2020

GJC

WOW

ELECTRICAL

SITE PLAN

E-002

NEW K-12

MULTI-SCHOOL

625-0518

CONSTRUCTION SET

SAVANNAH-CHATHAM

COUNTY PUBLIC SCHOOL

SYSTEM

SCALE: 1" = 80'-0"E-002

1 ELECTRICAL SITE PLAN

No. 32283

R T

PROFESSIONAL

OE

G

G I A

NE E

R

IG

N E

SIGE

R

ERE

D

O.

Y

W

E O

L

M

S

M

E

A

W

C K

No. Description Date

MULTI-MEDIA

BUILDING

FFE: 24.00

X

PP

PP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

O H

P

N U F/N

U T

NUF/NUT

NUF/NUT

NUF/NUT

NUF/NUT

NUF/NUT

NUF/NUT

NUF/NUT

NUF/NUT

NUF/NUT

NUF/NUT

N U

P

N U

P

N U

P N

U P

N U

P N

U P

N U

P N

U P

N U

P N

U P

FA

FA

NUS NUSNUS

4"C 4"C4"C

4"C 4"C

MULTI-MEDIA

CTAE BLDG

MEDIA BLDG

DATA ROOM

NOTE 3

NOTE 1

NOTE 2

NOTE 6

NOTE 7NOTE 7

UTILITY CO.

XFMR-MEDIA

MSB-M

GEN-MEDIA

A. SURVEY AND SITE INFORMATION PROVIDED BY OTHERS. VERIFY ALL

CONDITIONS ON SITE AND WITH OFFICIAL SURVEYS AND OTHER TRADES.

B. CONTACT UNDERGROUND UTILITY CENTER AND VERIFY ALL UNDERGROUND

UTILITIES.

C. UNDERGROUND CONDUIT SHALL BE SCHEDULE 40 PVC. PROVIDE GRS ELBOWS

PAINTED WITH BITUMINOUS PAINT TO TRANSITION TO ABOVE GRADE OR SLAB.

D. CONTRACTORS SHALL STAKE-OFF ALL EXISTING UTILITIES PRIOR TO ROUGH-IN.

ALL NEW INSTALLATION SHALL BE COORDINATED WITH EXISTING UTILITY

LOCATIONS.

E. CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL UTILITIES FOR THIS

PROJECT.

F. MINIMUM SIZE OF ALL CONDUITS ON THIS SHEET SHALL BE 3/4 IN.

G. PROVIDE PULL BOXES AS REQUIRED BY NEC FOR UNDERGROUND FEEDERS

SHOWN, SEE PULL BOX DETAIL.

1. UTILITY PAD MOUNTED TRANSFORMER AND METER. TRANSFORMER FURNISHED

AND INSTALLED BY UTILITY COMPANY. REFER TO RISER FOR ADDITIONAL

INFORMATION. SEE ARCHITECTURAL PLAN AND REFER TO UTILITY PAD MOUNTED

TRANSFORMER LOCATION DETAIL FOR LOCATIONS.

2. UNDERGROUND SECONDARY. REFER TO POWER RISER DIAGRAM.

3. PROPOSED ROUTE OF UTILITY PRIMARY. COORDINATE ROUTING WITH SUPPLYING

UTILITY. AVOID CONFLICTS WITH OTHER ITEMS AND POLE LOCATIONS.

4. PROVIDE (2)-4"C, MINIMUM DEPTH 30 INCHES BELOW GRADE. ROUTE TO NEAREST

CONNECTION POINT FOR TELEPHONE AND INTERNET SERVICE CONNECTIONS

COORDINATE CONNECTIONS WITH PROVIDER.

5. PROVIDE 4"C WITH (3) 1-1/4" INNERDUCTS FOR DATA, SECURITY, INTERCOM, AND

FIRE ALARM CONNECTION TO FIELD HOUSE.

6. PROVIDE MONITOR MODULE AT PIV. COORDINATE EXACT LOCATION OF PIV WITH

CIVIL CONTRACTOR.

7. SEE POWER RISER DIAGRAM, 1/E6.11 FOR FEEDER CONDUIT SIZE.

8. PROVIDE EMPTY 4"C UNDER ROADWAY FOR FUTURE USE. CONDUIT SHALL BE 24"

BELOW GRADE CAPPED ON BOTH ENDS. ABOVE EACH END, PROVIDE A 4" SQUARE

BY 24" DEEP CONCRETE MARKER. CONDUIT MARKER SHALL BE PAINTED INDUSTRIAL

YELLOW WHERE EXPOSED ABOVE GRADE.

9. PROVIDE 2#6,#8G PER CIRCUIT IN A 1-1/4"C FOR MONUMENT SIGN. COORDINATE

EXACT LOCATION OF MONUMENT SIGN WITH CIVIL DRAWINGS.

10. (GENERAL) GA POWER TO PROVIDE PARKING LOT LIGHTING.

11. (GENERAL) GA POWER RESPONSIBLE FOR REMOVAL / RELOCATION OF EXISTING

POLES, GUY WIRES, TRANSFORMERS, CABLES AND OTHER ASSOCIATED

ELECTRICAL UTILITY STRUCTURES. CONTRACTOR IS RESPONSIBLE TO COORDINATE

SCHEDULES AND CONFLICTS. SEE CIVIL PLAN FOR ADDITIONANL INFORMATION AND

CONTINUATION.

12. (GENERAL) PROVIDE ALLOWANCE FOR SIDEWALK LIGHTING.

GENERAL NOTES:

NOTES:

OVERHEAD PRIMARY

OVERHEAD SECONDARY

OVERHEAD TELEPHONE

UNDERGROUND FIBER

UNDERGROUND PRIMARY

UNDERGROUND SECONDARY

UNDERGROUND TELEPHONE

UNDERGROUND TELECOMMUNICATIONS

PAD-MOUNTED UTILITY CO. TRANSFORMER

PROVIDE PAD AS DETAILED.

POLE AND SIDEARM MOUNTED LIGHTING

FIXTURE SUPPLIED AND INSTALLED BY

GA POWER.

GENERATOR - SEE RISER DIAGRAM AND

SPECIFICATIONS.

OHP NOHP

OHS NOHS

OHT NOHT

UF NUF

UP NUP

US NUS

UT NUT

UTC NUTC

CONDUIT SLEEVE, SIZE NOTED. SEE NOTE 7.4"C

EXISTING NEW

A

B

C

D

F

E

GROUND COVER ON CONDUITS MAY BE REDUCED AT POINTS

OF CONNECTIONS TO BOXES.

SIZE OF BOXES SHALL CONFORM TO NFPA 70, BASED ON

CONDUITS ENTERING AND LEAVING BOXES. DEPTH OF BOX

AND EXTENSION SHALL BE 30" NOMINAL.

PROVIDE SEPARATE BOXES FOR MEDIUM VOLTAGE AND LOW

VOLTAGE SYSTEMS.

NO ENTRIES WILL BE ALLOWED THROUGH WALL OF EXTENSION.

ALL ENTRIES MUST BE MADE THROUGH MOUSEHOLES OR

ELBOWED FROM UNDERNEATH. ALL TERMINATIONS SHALL HAVE

SOME TYPE OF BUSHING.

SET BOXES FLUSH WITH FINISHED GRADE. LOCATIONS SHALL

BE APPROVED BY THE ARCHITECT.

SPECIFICATIONS:

ANSI TIER 15 RATING. 15,000 LBS VERTICAL DESIGN LOAD RATING.

COVER: HEAVY DUTY LOCKING TYPE WITH LOGO INDICATED.

COLOR: GRAY.

CONSTRUCTION: POLYMER CONCRETE WITH HEAVY-WEAVE

FIBERGLASS REINFORCEMENT.

NOTES:

TO SEAL

GROUT AROUND

ELECTRIC

EXTENSION

(FOR USE UNDER

BOX ONLY)

ELECTRIC

COVER

BOXHOLE

MOUSE

SKID RESISTANT

SURFACE

PULL SLOTS

BOLTS W/WASHERS

3/8"-16NC HEX

ASSEMBLY

MOUSE HOLES

(PULL BOX DETAIL)

SECONDARY OF THE TRANSFORMER SHALL FACE THE BUILDING (SWITCHGEAR).

CURRENT TRANSFORMER (CT) TO BE PROVIDED BY LOCAL POWER COMPANY AND

INSTALLED BY CONTACTOR.

PROVIDE ONE 1 1/4" RIGID GALVANIZED STEEL CONDUIT FROM CT TO ELECTRIC

METER. METER AND PEDISTAL TO BE SUPPLIED BY UTILITY COMPANY AND

INSTALLED BY CONTRACTOR. PEDISTAL SHALL BE BURIED MINIMUM 2'-0" DEEP,

SET IN CONCRETE.

CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION AND ARRANGEMENT WITH

SERVING UTILITY COMPANY FOR SERVICE CONNECTION (INCLUDING PAYMENT OF ALL

COSTS ASSOCIATED WITH THE SERVICE).

H

G

F

E

D

C

B

A

NOTES: (UTILITY PAD MOUNTED TRANSFORMER DETAIL)

EDGE OF TRANSFORMER PAD SHALL BE LOCATED MINIMUM 10'-0" MINIMUM FROM

WALKWAY, BALCONY, OVERHANGS, CANOPIES, AND EXTERIOR WALLS.

EDGE OF TRANSFORMER PAD SHALL BE LOCATED MINIMUM 14'-0" MINIMUM FROM

ANY DOOR.

IF BUILDING HAS AN OVERHANG AND IS 3 OR LESS FLOORS IN HEIGHT ABOVE THE

GROUND, THE 10 FOOT CLEARANCE IS MEASURED FROM A POINT BELOW THE EDGE

OF THE OVERHANG.

FIRE ESCAPES, OUTSIDE STAIRS AND WALKWAYS ATTATCHED TO OR BETWEEN

BUILDINGS SHALL BE CONSIDERED PART OF THE BUILDING.

EX

TE

R

IO

R W

AL

L

'-0

" M

IN

'-0

" M

IN

'-0

" M

IN

METER

10'-0" MIN.

OVERHANG

DOOR WINDOW

ACCESS

DOORS

CHECKED BY:

DRAWN BY:

DATE:

PROJECT:

REVISIONS:

MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS

A

2 3 4 5 6

B

C

D

E

COPYRIGHT 2019 ALL RIGHTS RESERVED

PRINTED OR ELECTRONIC DRAWINGS AND

DOCUMENTATION MAY NOT BE REPRODUCED

IN ANY FORM WITHOUT WRITTEN PERMISSION

FROM LS3P ASSOCIATES LTD.

WWW.LS3P.COM

SAVANNAH, GEORGIA 31401

TEL. 912.695.2111 FAX 912.298.0206

321 WEST CONGRESS STREET SUITE 301

/1

/2

:5 :3

P

M

B

IM

/S C

C P

S S

N e w

K -1

M u lt i- S c h o o l/ E

L E

C G ro v e s K

C

T A

E v .r v t

5201-192070

10/09/2020

GJC

WOW

ELECTRICAL

SITE PLAN -

MEDIA

BUILDING

/CTAE

E-003

NEW K-12

MULTI-SCHOOL

625-0518

CONSTRUCTION SET

SAVANNAH-CHATHAM

COUNTY PUBLIC SCHOOL

SYSTEM

SCALE: 1" = 40'-0"E-003

1 ELECTRICAL SITE PLAN - MEDIA BUILDING /CTAE

SCALE:NOT TO SCALEE-003

2 PULL BOX DETAIL

SCALE:NOT TO SCALEE-003

3 UTILITY PAD MOUNTED TRANSFORMER LOCATION

No. 32283

R T

PROFESSIONAL

OE

G

G I A

NE E

R

IG

N E

SIGE

R

ERE

D

O.

Y

W

E O

L

M

S

M

E

A

W

C

HD

W

AC

A C

AC

AC

A C

AC

A C

R R

R R

R R

R R

IC

IC

IC

AV

OFFICE

GREEN ROOM

DRESSING ROOM

109.1

CONFERENCE

MECH

JAN

ELEV

STUDIO

RISER

SECURE STOR

OFFICE

VESTIBULE

LOBBY

TOILET

TOILET

LOGISTICS

SUPPLY

PROJECT

CORRIDOR

AVIATION

Space

CORRIDOR

MEN

Space

WOMEN

C

C

WP

WP

WP

WP

WP

WP

WP

WP

WP

WP

36"

36"

36"

36"

36"

36"

36"

36"

36"

36"

36"36"

36"

36" 36"

36"

36"

C

LM1A

LM1B

LM1C

33 41

DATA

113.1

1 1

5 5

9 9

15 23

1 1

LM1A-21

LM1D

EHM1

LM1A-1,3,5

LM1A-7,9,11

LM1A-13

LM1A-15,17,19

LM1A-23 LM1B-1,3,5

LM1B-7,9,11

LM1B-13,15,17

LM1B-19,21

LM1C-1,3,5

HM1A

1 3 5

7 9 11

13 15 17

LM1D-1,3,5

LM1D-7,9,11

LM1D-13,15,17

LM1D-14,16,18 LM1D-115,117,119

HM1A-7,9,11

LM1D-8,10,12 LM1D-109,111,113

HM1A-1,3,5

LM1D-26,28,30 LM1D-91,93,95

HM1A-19,21,23

LM1D-56,58,60 LM1D-68,70,72

HM1A-37,39,41

LM1D-44,46,48 LM1D-74,76,78

HM1A-43,45,47

LM1D-50,52,54 LM1D-80,82,84

HM1A-49,51,53

LM1D-38,40,42 LM1D-103,105,107

HM1A-31,33,35

LM1D-20,22,24 LM1D-62,64,66

HM1A-13,15,17

LM1D-32,34,36 LM1D-97,99,101

HM1A-25,27,29

27 25

LM1D-61,63,65

LM1D-86,88,90

HM1A-2,4,6

LM1D-19,21,23

LM1D-2,4,6

LM1D-116,118,120

HM1A-32,34,36

LM1D-67,69,71

LM1D-92,94,96

HM1A-8,10,12

LM1D-79,81,83

LM1D-104,106,108

HM1A-20,22,24

LM1D-85,87,89

LM1D-110,112,114

HM1A-26,28,30

LM1D-73,75,77

LM1D-98,100,102

HM1A-14,16,18

LM1D-25,27,29

E-500

MSB-M

ELM1-1

ELM1

36"

36"

36"

36"

36"

36"

7 LM1C-7,9

LM1C-11,13,15

LM1C-23,25,27

LM1C-17,19,21

LM1C-29,31,33

LM1C-35,37

LM1C-39,41

LM1A-25

LM1B-23,25

23 25

LM1B-27,29

27 29

LM1B-31,33

31 33

LM1B-35,37

35 37

COORDINATE EXACT ELECTRICAL

REQUIREMENTS AND LOCATION

WITH EQUIPMENT BEING

INSTALLED. (TYP.)

MSB-M

TLM1D

TLM1A

TLM1B

TLM1C

ATS-EHM1

ATS-ELM1

ECB-ELM1

TELM1

TV

C

C

PROVIDE WATER-TIGHT, IN-GRADE TYPE

FLOOR BOX RATED FOR VEHICLE TRAFFIC

WITH REMOVABLE LID. BOX SHALL BE

PAINTED GALVANIZED STEEL. (TYPICAL)

GDS-EHM1

GDS-ELM1

CHECKED BY:

DRAWN BY:

DATE:

PROJECT:

REVISIONS:

MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS

A

2 3 4 5 6

B

C

D

E

COPYRIGHT 2019 ALL RIGHTS RESERVED

PRINTED OR ELECTRONIC DRAWINGS AND

DOCUMENTATION MAY NOT BE REPRODUCED

IN ANY FORM WITHOUT WRITTEN PERMISSION

FROM LS3P ASSOCIATES LTD.

WWW.LS3P.COM

SAVANNAH, GEORGIA 31401

TEL. 912.695.2111 FAX 912.298.0206

321 WEST CONGRESS STREET SUITE 301

/1

/2

:5 :5

P

M

B

IM

/S C

C P

S S

N e w

K -1

M u lt i- S c h o o l/ E

L E

C G ro v e s K

C

T A

E v .r v t

5201-192070

10/09/2020

PAA

WOW

1ST FLOOR -

POWER PLAN

E-201

NEW K-12

MULTI-SCHOOL

625-0518

CONSTRUCTION SET

SAVANNAH-CHATHAM

COUNTY PUBLIC SCHOOL

SYSTEM

SCALE: 1/8" = 1'-0"E-201

1 FIRST FLOOR - POWER PLAN

No. 32283

R T

PROFESSIONAL

OE

G

G I A

NE E

R

IG

N E

SIGE

R

ERE

D

O.

Y

W

E O

L

M

S

M

E

A

W

C K

No. Description Date

1 Addendum 3 10-30-20

GENERAL NOTES

A. DISTANCE LIMITATIONS FOR ALL 120 VOLT, 20A BRANCH CIRCUITS:

1. CIRCUIT LENGTHS EXCEEDING 70 FEET SHALL CONSIST OF NO. 10

AWG CIRCUIT CONDUCTORS.

2. CIRCUIT LENGTHS EXCEEDING 115 FEET SHALL CONSIST OF NO. 8

AWG CIRCUIT CONDUCTORS.

3. CIRCUIT LENGTHS EXCEEDING 180 FEET SHALL CONSIST OF NO. 6

AWG CIRCUIT CONDUCTORS.

4. CONDUIT SIZE SHALL BE INCREASED ACCORDINGLY

W

M

IC

IC

IC

IC

IC

A V

A V

AV

CORRIDOR

CONTROL

VEST

OFFICE

EDITING

CONTROL ROOM

DATA

213.1

ELEC

RECORDING

MECH

JAN

ELEV

OFFICE

MEN

WOMEN

TRAINING/ COMP LAB

COMPUTER SCIENCE

COMPUTER SCIENCE

COMPUTER SCIENCE

CORRIDOR

SECURE STOR

STAIR 1

STAIR 2

C

C

C

EDITING

STOR

LM2A

LM2B

1 1

9 9 9

15 17

5 5

25 21

9 9 9 9

355779

19 19 19

151313111119

29 23 25 25

29292929

31 31 33 33

373939

19 19

LM2A-1,3,5

LM2A-7,9,11

LM2A-13,15,17 LM2B-5,7,9

LM2B-1,3

LM2B-11,13,15

LM2B-17,19

LM2B-21,23,25

LM2B-27,29

LM2A-27

LM2A-21,23,25

LM2B-31,33,35

LM2B-37,39,41

LM2B-6,8

EHM2

E-500

MSB-M-7,9,11

ELM1-3,5

E-700

Sim

LM2A-19

ELM1-9

ELM2

TLM2B

ECB-LM2B

TLM2A

HM2A

C

C

ID

ID

ID

SEE 5/E-700

SEE 5/E-700

SEE 5/E-700

CHECKED BY:

DRAWN BY:

DATE:

PROJECT:

REVISIONS:

MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS

A

2 3 4 5 6

B

C

D

E

COPYRIGHT 2019 ALL RIGHTS RESERVED

PRINTED OR ELECTRONIC DRAWINGS AND

DOCUMENTATION MAY NOT BE REPRODUCED

IN ANY FORM WITHOUT WRITTEN PERMISSION

FROM LS3P ASSOCIATES LTD.

WWW.LS3P.COM

SAVANNAH, GEORGIA 31401

TEL. 912.695.2111 FAX 912.298.0206

321 WEST CONGRESS STREET SUITE 301

/1

/2

:5 :0

P

M

B

IM

/S C

C P

S S

N e w

K -1

M u lt i- S c h o o l/ E

L E

C G ro v e s K

C

T A

E v .r v t

5201-192070

10/09/2020

PAA

WOW

2ND FLOOR -

POWER PLAN

E-202

NEW K-12

MULTI-SCHOOL

625-0518

CONSTRUCTION SET

SAVANNAH-CHATHAM

COUNTY PUBLIC SCHOOL

SYSTEM

SCALE: 1/8" = 1'-0"E-202

1 SECOND FLOOR - POWER PLAN

No. 32283

R T

PROFESSIONAL

OE

G

G I A

NE E

R

IG

N E

SIGE

R

ERE

D

O.

Y

W

E O

L

M

S

M

E

A

W

C K

No. Description Date

GENERAL NOTES

A. DISTANCE LIMITATIONS FOR ALL 120 VOLT, 20A BRANCH CIRCUITS:

1. CIRCUIT LENGTHS EXCEEDING 70 FEET SHALL CONSIST OF NO. 10

AWG CIRCUIT CONDUCTORS.

2. CIRCUIT LENGTHS EXCEEDING 115 FEET SHALL CONSIST OF NO. 8

AWG CIRCUIT CONDUCTORS.

3. CIRCUIT LENGTHS EXCEEDING 180 FEET SHALL CONSIST OF NO. 6

AWG CIRCUIT CONDUCTORS.

4. CONDUIT SIZE SHALL BE INCREASED ACCORDINGLY

DATA

113.1

NOTE 3

(TYP.)

NOTE 1

NOTE 7

NOTE 2 NOTE 2 NOTE 2

NOTE 5

SEE 7/T-002

NOTE 9

(TYP.)

FACP

NOTE 4

ELM1-2

NOTE 10

151311

81012

ELM1-11,13,15

ELM1-4,6,8

ELM1-16,18

ELM1-10,12,14

ELM1-17

DATA

213.1

NOTE 3

(TYP.)

NOTE 1

NOTE 2 NOTE 2 NOTE 2

NOTE 6

SEE 8/T-002

NOTE 9

(TYP.)

NOTE 8

AUX

ELM2-25

NOTE 10

171921

ELM2-13,15,17

ELM2-9,11

ELM2-7

ELM2-1,3,5

ELM2-19,21,23

CHECKED BY:

DRAWN BY:

DATE:

PROJECT:

REVISIONS:

MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS

A

2 3 4 5 6

B

C

D

E

COPYRIGHT 2019 ALL RIGHTS RESERVED

PRINTED OR ELECTRONIC DRAWINGS AND

DOCUMENTATION MAY NOT BE REPRODUCED

IN ANY FORM WITHOUT WRITTEN PERMISSION

FROM LS3P ASSOCIATES LTD.

WWW.LS3P.COM

SAVANNAH, GEORGIA 31401

TEL. 912.695.2111 FAX 912.298.0206

321 WEST CONGRESS STREET SUITE 301

/1

/2

:5 :5

P

M

B

IM

/S C

C P

S S

N e w

K -1

M u lt i- S c h o o l/ E

L E

C G ro v e s K

C

T A

E v .r v t

5201-192070

10/09/2020

PAA

WOW

ENLARGED

PLANS

E-500

NEW K-12

MULTI-SCHOOL

625-0518

CONSTRUCTION SET

SAVANNAH-CHATHAM

COUNTY PUBLIC SCHOOL

SYSTEM

SCALE: 1/2" = 1'-0"E-500

1 ENLARGED DATA 113.1

NOTES

1. PROVIDE 4#10 HOMERUN, 3/4" C. FOR FUTURE UPS POWER.

2. RECEPTACLE SHALL BE INSTALLED IN THE TELECOMMUNICATION RACK.

COORDINATE EXACT LOCATION WITH TELECOMMUNICATION RACK INSTALLER.

3. PLYWOOD BACKBOARD: PROVIDE 3*4" THICK, FIRE RETARDANT GRADE A/C

PLYWOOD BACKBOARD, COAT PLYWOOD WITH TWO COATES LIGHT GRAY FIRE

RETARDANT PAINT. FIRE RATING ON PLYWOOD SHALL NOT BE PAINTED OVER SO

AT LEAST ONE MARKING SHALL BE VISIBLE ON EACH PIECE OF PLYWOOD. PROVIDE

3/4" X 3/4" ALUMINUM ANGLE FRAME AFTER PAINTING. PROVIDE OUTLET BOX

EXTENSION RING AS REQUIRED FOR DEVICES INSTALLED IN WALL RECEIVING

PLYWOOD FOR FLUSH MOUNTING WITH WOOD SURFACE.

4. TELEPHONE DEMARC: PROVIDE TELEPHONE CABLE AND 66-BLOCK FOR

FOLLOWING: EMERGENCY 911 BACKUP LINES (2), FIRE ALARM (1), INTRUSION

DETECTION ALARM (1), ELEVATOR (2). COORDINATE WITH ELECTRIC SITE PLAN FOR

ADDITIONAL CONDUIT ROUTING INFORMATION.

5. PROVIDE 12" TELECOMMUNICATIONS MAIN GROUNDING BUSBAR (TMGB). TMGB

SHALL BE MADE OF 1/4" THICK ELECTROLYTIC, TIN-PLATED COPPER AND UL

LISTED.

6. PROVIDE 12" TELECOMMUNICATIONS GROUNDING BUSBAR (TGB). TGB SHALL BE

MADE OF 1/4" THICK ELECTROLYTIC, TIN-PLATED COPPER AND UL LISTED.

7. PROVIDE (2) 4" EMT CONDUIT SLEEVES UP THROUGH CEILING. BOTH ENDS OF

CONDUIT SLEEVES ARE TO BE BUSHED. ALL PENETRATIONS ARE TO BE SEALED IN

ACCORDANCE WITH CONTRACT SPECIFICATIONS. ALL CONDUIT SLEEVES ARE TO

BE BONDED TO THE TELECOMMUNICATIONS GROUNDING AND BONDING SYSTEM

PER TYPICAL TELECOM METALLIC CONDUIT BONDING DETAIL.

8. (2) 4" EMT CONDUIT SLEEVES UP THROUGH FLOOR. BOTH ENDS OF CONDUIT

SLEEVES ARE TO BE BUSHED. ALL PENETRATIONS ARE TO BE SEALED IN

ACCORDANCE WITH CONTRACT SPECIFICATIONS. ALL CONDUIT SLEEVES ARE TO

BE BONDED TO THE TELECOMMUNICATIONS GROUNDING AND BONDING SYSTEM

PER TYPICAL TELECOM METALLIC CONDUIT BONDING DETAIL.

9. PROVIDE 18" WIDE LADDER RACK/CABLE TRAY. CABLE TRAY SHALL BE SECURED

TO WALL OR SECURELY SUSPENDED FROM CEILING STRUCTURE. PROVIDE

LENGTH AND QUANTITY PER PLANS.

10. LABEL BREAKER WITH RED NAMEPLATE “FIRE ALARM CONTROL PANEL”. LABEL

FIRE ALARM CONTROL PANEL WITH CIRCUIT NUMBER SERVING IT. PROVIDE

BREAKER LOCK FOR CIRCUIT BREAKER.

SCALE: 1/2" = 1'-0"E-500

2 ENLARGED DATA 213.1

No. 32283

R T

PROFESSIONAL

OE

G

G I A

NE E

R

IG

N E

SIGE

R

ERE

D

O.

Y

W

E O

L

M

S

M

E

A

W

C

Other files

File Type Posted
RFP 22-28 Sample Contract —
Data Security CTAE Media —
Data Closet Main Bldg —
Award Information —
BACKBONE CABLING —
RFP 22-28 Solicitation Documen —
Data Closets CTAE Media —
RFP 22-28 Addendum 1 —
Technology Design Plan —
HORIZONTAL CABLING —

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file