Electrical CTAE Media
2 MB Posted
- Attached to
- Data Cabling for New Groves K-12 School (ERATE)
- Solicitation number
- RFP22-28
- Issued by
- Chatham County, Georgia
About this file
This file consists of electrical construction drawings and site plans for the Electrical CTAE Media Building component of a new K-12 multi-school project undertaken by the Savannah-Chatham County Public School System (SCCPSS) in Georgia. The drawings, prepared by LS3P Associates Ltd. and dated October 9, 2020, with revisions through February 18, 2021, detail the electrical infrastructure requirements for the Media Building/CTAE facility, including site electrical plans (E-002, E-003), first and second floor power plans (E-201, E-202), and enlarged detailed plans (E-500). The project encompasses multiple buildings with varying finished floor elevations: the Fieldhouse (24.20), Multi-Media Building (24.00), K-12 Building (23.00), Baseball Concessions (23.75), and various other concession facilities. The electrical site plan specifies underground conduit routing (minimum 3/4" Schedule 40 PVC), pad-mounted utility company transformers, pull boxes, and comprehensive utility coordination requirements, including provisions for data, security, intercom, and fire alarm connections. The drawings establish specific technical standards such as distance limitations for 120-volt, 20-ampere branch circuits, with conductor sizing requirements for circuit lengths exceeding 70, 115, and 180 feet.
The specifications detail critical electrical infrastructure components including utility transformer pads with minimum clearances of 10 feet from walkways and 14 feet from doors, water-tight in-grade floor boxes rated for vehicle traffic, and extensive telecommunications provisions including main grounding busbars, cable trays, and metallic conduit bonding systems. The project incorporates multiple electrical distribution systems including panel boards (MSB-M, ELM1, ELM2), automatic transfer switches (ATS-EHM1, ATS-ELM1), and fire alarm control panel circuits with dedicated breaker lockouts and red nameplates. Underground utility work requires coordination with the utility company for transformer furnishing and installation, with the contractor responsible for all utility coordination, underground utility verification through the Underground Utility Center, and staking of existing utilities prior to rough-in. The drawings indicate that GA Power is responsible for parking lot lighting supply and installation as well as removal and relocation of existing poles, guy wires, transformers, and associated electrical utility structures, with contractors coordinating all schedules and conflicts.
Text of this file
106 138
154 130
130 114
146154
138130
138 130
178210
106 106
106106
130 130
2955 2955
138138
12 12
36 3636
2 48
FIELDHOUSE
FFE: 24.20
MULTI-MEDIA
BUILDING
FFE: 24.00
K-12
BUILDING
FFE: 23.00
BASEBALL
CONC & REST
CONCESSIONS
FFE: 23.75
CONCESSIONS
FFE:
23.80
CONCESSIONS
FFE:
23.84
D OWN
D OWN
D O W N
D O W N
D O W N
D O W N
2 00 025 0432 422n1 n1
X X
E-003
UTIL CO.
XFMR
GEN-F
STADIUM FIELD HOUSE
AND POLICE ANNEX
BASEBALL
YOUTH BASEBALL
SOFTBALL
MULTI-PURPOSE
COMPETITION FIELD
TENNIS
COURTS
FEILD CONCESSION BUILDING
SOCCER FIELD
MULTI-MEDIA
CTAE BLDG
NEW K-12
MULTI-SCHOOL
GEN-MEDIA
UTILITY CO.
XFMR-MEDIA
MSB-M
CHECKED BY:
DRAWN BY:
DATE:
PROJECT:
REVISIONS:
MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS
A
2 3 4 5 6
B
C
D
E
COPYRIGHT 2019 ALL RIGHTS RESERVED
PRINTED OR ELECTRONIC DRAWINGS AND
DOCUMENTATION MAY NOT BE REPRODUCED
IN ANY FORM WITHOUT WRITTEN PERMISSION
FROM LS3P ASSOCIATES LTD.
WWW.LS3P.COM
SAVANNAH, GEORGIA 31401
TEL. 912.695.2111 FAX 912.298.0206
321 WEST CONGRESS STREET SUITE 301
/1
/2
:5 :2
P
M
B
IM
/S C
C P
S S
N e w
K -1
M u lt i- S c h o o l/ E
L E
C G ro v e s K
C
T A
E v .r v t
5201-192070
10/09/2020
GJC
WOW
ELECTRICAL
SITE PLAN
E-002
NEW K-12
MULTI-SCHOOL
625-0518
CONSTRUCTION SET
SAVANNAH-CHATHAM
COUNTY PUBLIC SCHOOL
SYSTEM
SCALE: 1" = 80'-0"E-002
1 ELECTRICAL SITE PLAN
No. 32283
R T
PROFESSIONAL
OE
G
G I A
NE E
R
IG
N E
SIGE
R
ERE
D
O.
Y
W
E O
L
M
S
M
E
A
W
C K
No. Description Date
MULTI-MEDIA
BUILDING
FFE: 24.00
X
PP
PP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
O H
P
N U F/N
U T
NUF/NUT
NUF/NUT
NUF/NUT
NUF/NUT
NUF/NUT
NUF/NUT
NUF/NUT
NUF/NUT
NUF/NUT
NUF/NUT
N U
P
N U
P
N U
P N
U P
N U
P N
U P
N U
P N
U P
N U
P N
U P
FA
FA
NUS NUSNUS
4"C 4"C4"C
4"C 4"C
MULTI-MEDIA
CTAE BLDG
MEDIA BLDG
DATA ROOM
NOTE 3
NOTE 1
NOTE 2
NOTE 6
NOTE 7NOTE 7
UTILITY CO.
XFMR-MEDIA
MSB-M
GEN-MEDIA
A. SURVEY AND SITE INFORMATION PROVIDED BY OTHERS. VERIFY ALL
CONDITIONS ON SITE AND WITH OFFICIAL SURVEYS AND OTHER TRADES.
B. CONTACT UNDERGROUND UTILITY CENTER AND VERIFY ALL UNDERGROUND
UTILITIES.
C. UNDERGROUND CONDUIT SHALL BE SCHEDULE 40 PVC. PROVIDE GRS ELBOWS
PAINTED WITH BITUMINOUS PAINT TO TRANSITION TO ABOVE GRADE OR SLAB.
D. CONTRACTORS SHALL STAKE-OFF ALL EXISTING UTILITIES PRIOR TO ROUGH-IN.
ALL NEW INSTALLATION SHALL BE COORDINATED WITH EXISTING UTILITY
LOCATIONS.
E. CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL UTILITIES FOR THIS
PROJECT.
F. MINIMUM SIZE OF ALL CONDUITS ON THIS SHEET SHALL BE 3/4 IN.
G. PROVIDE PULL BOXES AS REQUIRED BY NEC FOR UNDERGROUND FEEDERS
SHOWN, SEE PULL BOX DETAIL.
1. UTILITY PAD MOUNTED TRANSFORMER AND METER. TRANSFORMER FURNISHED
AND INSTALLED BY UTILITY COMPANY. REFER TO RISER FOR ADDITIONAL
INFORMATION. SEE ARCHITECTURAL PLAN AND REFER TO UTILITY PAD MOUNTED
TRANSFORMER LOCATION DETAIL FOR LOCATIONS.
2. UNDERGROUND SECONDARY. REFER TO POWER RISER DIAGRAM.
3. PROPOSED ROUTE OF UTILITY PRIMARY. COORDINATE ROUTING WITH SUPPLYING
UTILITY. AVOID CONFLICTS WITH OTHER ITEMS AND POLE LOCATIONS.
4. PROVIDE (2)-4"C, MINIMUM DEPTH 30 INCHES BELOW GRADE. ROUTE TO NEAREST
CONNECTION POINT FOR TELEPHONE AND INTERNET SERVICE CONNECTIONS
COORDINATE CONNECTIONS WITH PROVIDER.
5. PROVIDE 4"C WITH (3) 1-1/4" INNERDUCTS FOR DATA, SECURITY, INTERCOM, AND
FIRE ALARM CONNECTION TO FIELD HOUSE.
6. PROVIDE MONITOR MODULE AT PIV. COORDINATE EXACT LOCATION OF PIV WITH
CIVIL CONTRACTOR.
7. SEE POWER RISER DIAGRAM, 1/E6.11 FOR FEEDER CONDUIT SIZE.
8. PROVIDE EMPTY 4"C UNDER ROADWAY FOR FUTURE USE. CONDUIT SHALL BE 24"
BELOW GRADE CAPPED ON BOTH ENDS. ABOVE EACH END, PROVIDE A 4" SQUARE
BY 24" DEEP CONCRETE MARKER. CONDUIT MARKER SHALL BE PAINTED INDUSTRIAL
YELLOW WHERE EXPOSED ABOVE GRADE.
9. PROVIDE 2#6,#8G PER CIRCUIT IN A 1-1/4"C FOR MONUMENT SIGN. COORDINATE
EXACT LOCATION OF MONUMENT SIGN WITH CIVIL DRAWINGS.
10. (GENERAL) GA POWER TO PROVIDE PARKING LOT LIGHTING.
11. (GENERAL) GA POWER RESPONSIBLE FOR REMOVAL / RELOCATION OF EXISTING
POLES, GUY WIRES, TRANSFORMERS, CABLES AND OTHER ASSOCIATED
ELECTRICAL UTILITY STRUCTURES. CONTRACTOR IS RESPONSIBLE TO COORDINATE
SCHEDULES AND CONFLICTS. SEE CIVIL PLAN FOR ADDITIONANL INFORMATION AND
CONTINUATION.
12. (GENERAL) PROVIDE ALLOWANCE FOR SIDEWALK LIGHTING.
GENERAL NOTES:
NOTES:
OVERHEAD PRIMARY
OVERHEAD SECONDARY
OVERHEAD TELEPHONE
UNDERGROUND FIBER
UNDERGROUND PRIMARY
UNDERGROUND SECONDARY
UNDERGROUND TELEPHONE
UNDERGROUND TELECOMMUNICATIONS
PAD-MOUNTED UTILITY CO. TRANSFORMER
PROVIDE PAD AS DETAILED.
POLE AND SIDEARM MOUNTED LIGHTING
FIXTURE SUPPLIED AND INSTALLED BY
GA POWER.
GENERATOR - SEE RISER DIAGRAM AND
SPECIFICATIONS.
OHP NOHP
OHS NOHS
OHT NOHT
UF NUF
UP NUP
US NUS
UT NUT
UTC NUTC
CONDUIT SLEEVE, SIZE NOTED. SEE NOTE 7.4"C
EXISTING NEW
A
B
C
D
F
E
GROUND COVER ON CONDUITS MAY BE REDUCED AT POINTS
OF CONNECTIONS TO BOXES.
SIZE OF BOXES SHALL CONFORM TO NFPA 70, BASED ON
CONDUITS ENTERING AND LEAVING BOXES. DEPTH OF BOX
AND EXTENSION SHALL BE 30" NOMINAL.
PROVIDE SEPARATE BOXES FOR MEDIUM VOLTAGE AND LOW
VOLTAGE SYSTEMS.
NO ENTRIES WILL BE ALLOWED THROUGH WALL OF EXTENSION.
ALL ENTRIES MUST BE MADE THROUGH MOUSEHOLES OR
ELBOWED FROM UNDERNEATH. ALL TERMINATIONS SHALL HAVE
SOME TYPE OF BUSHING.
SET BOXES FLUSH WITH FINISHED GRADE. LOCATIONS SHALL
BE APPROVED BY THE ARCHITECT.
SPECIFICATIONS:
ANSI TIER 15 RATING. 15,000 LBS VERTICAL DESIGN LOAD RATING.
COVER: HEAVY DUTY LOCKING TYPE WITH LOGO INDICATED.
COLOR: GRAY.
CONSTRUCTION: POLYMER CONCRETE WITH HEAVY-WEAVE
FIBERGLASS REINFORCEMENT.
NOTES:
TO SEAL
GROUT AROUND
ELECTRIC
EXTENSION
(FOR USE UNDER
BOX ONLY)
ELECTRIC
COVER
BOXHOLE
MOUSE
SKID RESISTANT
SURFACE
PULL SLOTS
BOLTS W/WASHERS
3/8"-16NC HEX
ASSEMBLY
MOUSE HOLES
(PULL BOX DETAIL)
SECONDARY OF THE TRANSFORMER SHALL FACE THE BUILDING (SWITCHGEAR).
CURRENT TRANSFORMER (CT) TO BE PROVIDED BY LOCAL POWER COMPANY AND
INSTALLED BY CONTACTOR.
PROVIDE ONE 1 1/4" RIGID GALVANIZED STEEL CONDUIT FROM CT TO ELECTRIC
METER. METER AND PEDISTAL TO BE SUPPLIED BY UTILITY COMPANY AND
INSTALLED BY CONTRACTOR. PEDISTAL SHALL BE BURIED MINIMUM 2'-0" DEEP,
SET IN CONCRETE.
CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION AND ARRANGEMENT WITH
SERVING UTILITY COMPANY FOR SERVICE CONNECTION (INCLUDING PAYMENT OF ALL
COSTS ASSOCIATED WITH THE SERVICE).
H
G
F
E
D
C
B
A
NOTES: (UTILITY PAD MOUNTED TRANSFORMER DETAIL)
EDGE OF TRANSFORMER PAD SHALL BE LOCATED MINIMUM 10'-0" MINIMUM FROM
WALKWAY, BALCONY, OVERHANGS, CANOPIES, AND EXTERIOR WALLS.
EDGE OF TRANSFORMER PAD SHALL BE LOCATED MINIMUM 14'-0" MINIMUM FROM
ANY DOOR.
IF BUILDING HAS AN OVERHANG AND IS 3 OR LESS FLOORS IN HEIGHT ABOVE THE
GROUND, THE 10 FOOT CLEARANCE IS MEASURED FROM A POINT BELOW THE EDGE
OF THE OVERHANG.
FIRE ESCAPES, OUTSIDE STAIRS AND WALKWAYS ATTATCHED TO OR BETWEEN
BUILDINGS SHALL BE CONSIDERED PART OF THE BUILDING.
EX
TE
R
IO
R W
AL
L
'-0
" M
IN
'-0
" M
IN
'-0
" M
IN
METER
10'-0" MIN.
OVERHANG
DOOR WINDOW
ACCESS
DOORS
CHECKED BY:
DRAWN BY:
DATE:
PROJECT:
REVISIONS:
MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS
A
2 3 4 5 6
B
C
D
E
COPYRIGHT 2019 ALL RIGHTS RESERVED
PRINTED OR ELECTRONIC DRAWINGS AND
DOCUMENTATION MAY NOT BE REPRODUCED
IN ANY FORM WITHOUT WRITTEN PERMISSION
FROM LS3P ASSOCIATES LTD.
WWW.LS3P.COM
SAVANNAH, GEORGIA 31401
TEL. 912.695.2111 FAX 912.298.0206
321 WEST CONGRESS STREET SUITE 301
/1
/2
:5 :3
P
M
B
IM
/S C
C P
S S
N e w
K -1
M u lt i- S c h o o l/ E
L E
C G ro v e s K
C
T A
E v .r v t
5201-192070
10/09/2020
GJC
WOW
ELECTRICAL
SITE PLAN -
MEDIA
BUILDING
/CTAE
E-003
NEW K-12
MULTI-SCHOOL
625-0518
CONSTRUCTION SET
SAVANNAH-CHATHAM
COUNTY PUBLIC SCHOOL
SYSTEM
SCALE: 1" = 40'-0"E-003
1 ELECTRICAL SITE PLAN - MEDIA BUILDING /CTAE
SCALE:NOT TO SCALEE-003
2 PULL BOX DETAIL
SCALE:NOT TO SCALEE-003
3 UTILITY PAD MOUNTED TRANSFORMER LOCATION
No. 32283
R T
PROFESSIONAL
OE
G
G I A
NE E
R
IG
N E
SIGE
R
ERE
D
O.
Y
W
E O
L
M
S
M
E
A
W
C
HD
W
AC
A C
AC
AC
A C
AC
A C
R R
R R
R R
R R
IC
IC
IC
AV
OFFICE
GREEN ROOM
DRESSING ROOM
109.1
CONFERENCE
MECH
JAN
ELEV
STUDIO
RISER
SECURE STOR
OFFICE
VESTIBULE
LOBBY
TOILET
TOILET
LOGISTICS
SUPPLY
PROJECT
CORRIDOR
AVIATION
Space
CORRIDOR
MEN
Space
WOMEN
C
C
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
36"
36"
36"
36"
36"
36"
36"
36"
36"
36"
36"36"
36"
36" 36"
36"
36"
C
LM1A
LM1B
LM1C
33 41
DATA
113.1
1 1
5 5
9 9
15 23
1 1
LM1A-21
LM1D
EHM1
LM1A-1,3,5
LM1A-7,9,11
LM1A-13
LM1A-15,17,19
LM1A-23 LM1B-1,3,5
LM1B-7,9,11
LM1B-13,15,17
LM1B-19,21
LM1C-1,3,5
HM1A
1 3 5
7 9 11
13 15 17
LM1D-1,3,5
LM1D-7,9,11
LM1D-13,15,17
LM1D-14,16,18 LM1D-115,117,119
HM1A-7,9,11
LM1D-8,10,12 LM1D-109,111,113
HM1A-1,3,5
LM1D-26,28,30 LM1D-91,93,95
HM1A-19,21,23
LM1D-56,58,60 LM1D-68,70,72
HM1A-37,39,41
LM1D-44,46,48 LM1D-74,76,78
HM1A-43,45,47
LM1D-50,52,54 LM1D-80,82,84
HM1A-49,51,53
LM1D-38,40,42 LM1D-103,105,107
HM1A-31,33,35
LM1D-20,22,24 LM1D-62,64,66
HM1A-13,15,17
LM1D-32,34,36 LM1D-97,99,101
HM1A-25,27,29
27 25
LM1D-61,63,65
LM1D-86,88,90
HM1A-2,4,6
LM1D-19,21,23
LM1D-2,4,6
LM1D-116,118,120
HM1A-32,34,36
LM1D-67,69,71
LM1D-92,94,96
HM1A-8,10,12
LM1D-79,81,83
LM1D-104,106,108
HM1A-20,22,24
LM1D-85,87,89
LM1D-110,112,114
HM1A-26,28,30
LM1D-73,75,77
LM1D-98,100,102
HM1A-14,16,18
LM1D-25,27,29
E-500
MSB-M
ELM1-1
ELM1
36"
36"
36"
36"
36"
36"
7 LM1C-7,9
LM1C-11,13,15
LM1C-23,25,27
LM1C-17,19,21
LM1C-29,31,33
LM1C-35,37
LM1C-39,41
LM1A-25
LM1B-23,25
23 25
LM1B-27,29
27 29
LM1B-31,33
31 33
LM1B-35,37
35 37
COORDINATE EXACT ELECTRICAL
REQUIREMENTS AND LOCATION
WITH EQUIPMENT BEING
INSTALLED. (TYP.)
MSB-M
TLM1D
TLM1A
TLM1B
TLM1C
ATS-EHM1
ATS-ELM1
ECB-ELM1
TELM1
TV
C
C
PROVIDE WATER-TIGHT, IN-GRADE TYPE
FLOOR BOX RATED FOR VEHICLE TRAFFIC
WITH REMOVABLE LID. BOX SHALL BE
PAINTED GALVANIZED STEEL. (TYPICAL)
GDS-EHM1
GDS-ELM1
CHECKED BY:
DRAWN BY:
DATE:
PROJECT:
REVISIONS:
MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS
A
2 3 4 5 6
B
C
D
E
COPYRIGHT 2019 ALL RIGHTS RESERVED
PRINTED OR ELECTRONIC DRAWINGS AND
DOCUMENTATION MAY NOT BE REPRODUCED
IN ANY FORM WITHOUT WRITTEN PERMISSION
FROM LS3P ASSOCIATES LTD.
WWW.LS3P.COM
SAVANNAH, GEORGIA 31401
TEL. 912.695.2111 FAX 912.298.0206
321 WEST CONGRESS STREET SUITE 301
/1
/2
:5 :5
P
M
B
IM
/S C
C P
S S
N e w
K -1
M u lt i- S c h o o l/ E
L E
C G ro v e s K
C
T A
E v .r v t
5201-192070
10/09/2020
PAA
WOW
1ST FLOOR -
POWER PLAN
E-201
NEW K-12
MULTI-SCHOOL
625-0518
CONSTRUCTION SET
SAVANNAH-CHATHAM
COUNTY PUBLIC SCHOOL
SYSTEM
SCALE: 1/8" = 1'-0"E-201
1 FIRST FLOOR - POWER PLAN
No. 32283
R T
PROFESSIONAL
OE
G
G I A
NE E
R
IG
N E
SIGE
R
ERE
D
O.
Y
W
E O
L
M
S
M
E
A
W
C K
No. Description Date
1 Addendum 3 10-30-20
GENERAL NOTES
A. DISTANCE LIMITATIONS FOR ALL 120 VOLT, 20A BRANCH CIRCUITS:
1. CIRCUIT LENGTHS EXCEEDING 70 FEET SHALL CONSIST OF NO. 10
AWG CIRCUIT CONDUCTORS.
2. CIRCUIT LENGTHS EXCEEDING 115 FEET SHALL CONSIST OF NO. 8
AWG CIRCUIT CONDUCTORS.
3. CIRCUIT LENGTHS EXCEEDING 180 FEET SHALL CONSIST OF NO. 6
AWG CIRCUIT CONDUCTORS.
4. CONDUIT SIZE SHALL BE INCREASED ACCORDINGLY
W
M
IC
IC
IC
IC
IC
A V
A V
AV
CORRIDOR
CONTROL
VEST
OFFICE
EDITING
CONTROL ROOM
DATA
213.1
ELEC
RECORDING
MECH
JAN
ELEV
OFFICE
MEN
WOMEN
TRAINING/ COMP LAB
COMPUTER SCIENCE
COMPUTER SCIENCE
COMPUTER SCIENCE
CORRIDOR
SECURE STOR
STAIR 1
STAIR 2
C
C
C
EDITING
STOR
LM2A
LM2B
1 1
9 9 9
15 17
5 5
25 21
9 9 9 9
355779
19 19 19
151313111119
29 23 25 25
29292929
31 31 33 33
373939
19 19
LM2A-1,3,5
LM2A-7,9,11
LM2A-13,15,17 LM2B-5,7,9
LM2B-1,3
LM2B-11,13,15
LM2B-17,19
LM2B-21,23,25
LM2B-27,29
LM2A-27
LM2A-21,23,25
LM2B-31,33,35
LM2B-37,39,41
LM2B-6,8
EHM2
E-500
MSB-M-7,9,11
ELM1-3,5
E-700
Sim
LM2A-19
ELM1-9
ELM2
TLM2B
ECB-LM2B
TLM2A
HM2A
C
C
ID
ID
ID
SEE 5/E-700
SEE 5/E-700
SEE 5/E-700
CHECKED BY:
DRAWN BY:
DATE:
PROJECT:
REVISIONS:
MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS
A
2 3 4 5 6
B
C
D
E
COPYRIGHT 2019 ALL RIGHTS RESERVED
PRINTED OR ELECTRONIC DRAWINGS AND
DOCUMENTATION MAY NOT BE REPRODUCED
IN ANY FORM WITHOUT WRITTEN PERMISSION
FROM LS3P ASSOCIATES LTD.
WWW.LS3P.COM
SAVANNAH, GEORGIA 31401
TEL. 912.695.2111 FAX 912.298.0206
321 WEST CONGRESS STREET SUITE 301
/1
/2
:5 :0
P
M
B
IM
/S C
C P
S S
N e w
K -1
M u lt i- S c h o o l/ E
L E
C G ro v e s K
C
T A
E v .r v t
5201-192070
10/09/2020
PAA
WOW
2ND FLOOR -
POWER PLAN
E-202
NEW K-12
MULTI-SCHOOL
625-0518
CONSTRUCTION SET
SAVANNAH-CHATHAM
COUNTY PUBLIC SCHOOL
SYSTEM
SCALE: 1/8" = 1'-0"E-202
1 SECOND FLOOR - POWER PLAN
No. 32283
R T
PROFESSIONAL
OE
G
G I A
NE E
R
IG
N E
SIGE
R
ERE
D
O.
Y
W
E O
L
M
S
M
E
A
W
C K
No. Description Date
GENERAL NOTES
A. DISTANCE LIMITATIONS FOR ALL 120 VOLT, 20A BRANCH CIRCUITS:
1. CIRCUIT LENGTHS EXCEEDING 70 FEET SHALL CONSIST OF NO. 10
AWG CIRCUIT CONDUCTORS.
2. CIRCUIT LENGTHS EXCEEDING 115 FEET SHALL CONSIST OF NO. 8
AWG CIRCUIT CONDUCTORS.
3. CIRCUIT LENGTHS EXCEEDING 180 FEET SHALL CONSIST OF NO. 6
AWG CIRCUIT CONDUCTORS.
4. CONDUIT SIZE SHALL BE INCREASED ACCORDINGLY
DATA
113.1
NOTE 3
(TYP.)
NOTE 1
NOTE 7
NOTE 2 NOTE 2 NOTE 2
NOTE 5
SEE 7/T-002
NOTE 9
(TYP.)
FACP
NOTE 4
ELM1-2
NOTE 10
151311
81012
ELM1-11,13,15
ELM1-4,6,8
ELM1-16,18
ELM1-10,12,14
ELM1-17
DATA
213.1
NOTE 3
(TYP.)
NOTE 1
NOTE 2 NOTE 2 NOTE 2
NOTE 6
SEE 8/T-002
NOTE 9
(TYP.)
NOTE 8
AUX
ELM2-25
NOTE 10
171921
ELM2-13,15,17
ELM2-9,11
ELM2-7
ELM2-1,3,5
ELM2-19,21,23
CHECKED BY:
DRAWN BY:
DATE:
PROJECT:
REVISIONS:
MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS
A
2 3 4 5 6
B
C
D
E
COPYRIGHT 2019 ALL RIGHTS RESERVED
PRINTED OR ELECTRONIC DRAWINGS AND
DOCUMENTATION MAY NOT BE REPRODUCED
IN ANY FORM WITHOUT WRITTEN PERMISSION
FROM LS3P ASSOCIATES LTD.
WWW.LS3P.COM
SAVANNAH, GEORGIA 31401
TEL. 912.695.2111 FAX 912.298.0206
321 WEST CONGRESS STREET SUITE 301
/1
/2
:5 :5
P
M
B
IM
/S C
C P
S S
N e w
K -1
M u lt i- S c h o o l/ E
L E
C G ro v e s K
C
T A
E v .r v t
5201-192070
10/09/2020
PAA
WOW
ENLARGED
PLANS
E-500
NEW K-12
MULTI-SCHOOL
625-0518
CONSTRUCTION SET
SAVANNAH-CHATHAM
COUNTY PUBLIC SCHOOL
SYSTEM
SCALE: 1/2" = 1'-0"E-500
1 ENLARGED DATA 113.1
NOTES
1. PROVIDE 4#10 HOMERUN, 3/4" C. FOR FUTURE UPS POWER.
2. RECEPTACLE SHALL BE INSTALLED IN THE TELECOMMUNICATION RACK.
COORDINATE EXACT LOCATION WITH TELECOMMUNICATION RACK INSTALLER.
3. PLYWOOD BACKBOARD: PROVIDE 3*4" THICK, FIRE RETARDANT GRADE A/C
PLYWOOD BACKBOARD, COAT PLYWOOD WITH TWO COATES LIGHT GRAY FIRE
RETARDANT PAINT. FIRE RATING ON PLYWOOD SHALL NOT BE PAINTED OVER SO
AT LEAST ONE MARKING SHALL BE VISIBLE ON EACH PIECE OF PLYWOOD. PROVIDE
3/4" X 3/4" ALUMINUM ANGLE FRAME AFTER PAINTING. PROVIDE OUTLET BOX
EXTENSION RING AS REQUIRED FOR DEVICES INSTALLED IN WALL RECEIVING
PLYWOOD FOR FLUSH MOUNTING WITH WOOD SURFACE.
4. TELEPHONE DEMARC: PROVIDE TELEPHONE CABLE AND 66-BLOCK FOR
FOLLOWING: EMERGENCY 911 BACKUP LINES (2), FIRE ALARM (1), INTRUSION
DETECTION ALARM (1), ELEVATOR (2). COORDINATE WITH ELECTRIC SITE PLAN FOR
ADDITIONAL CONDUIT ROUTING INFORMATION.
5. PROVIDE 12" TELECOMMUNICATIONS MAIN GROUNDING BUSBAR (TMGB). TMGB
SHALL BE MADE OF 1/4" THICK ELECTROLYTIC, TIN-PLATED COPPER AND UL
LISTED.
6. PROVIDE 12" TELECOMMUNICATIONS GROUNDING BUSBAR (TGB). TGB SHALL BE
MADE OF 1/4" THICK ELECTROLYTIC, TIN-PLATED COPPER AND UL LISTED.
7. PROVIDE (2) 4" EMT CONDUIT SLEEVES UP THROUGH CEILING. BOTH ENDS OF
CONDUIT SLEEVES ARE TO BE BUSHED. ALL PENETRATIONS ARE TO BE SEALED IN
ACCORDANCE WITH CONTRACT SPECIFICATIONS. ALL CONDUIT SLEEVES ARE TO
BE BONDED TO THE TELECOMMUNICATIONS GROUNDING AND BONDING SYSTEM
PER TYPICAL TELECOM METALLIC CONDUIT BONDING DETAIL.
8. (2) 4" EMT CONDUIT SLEEVES UP THROUGH FLOOR. BOTH ENDS OF CONDUIT
SLEEVES ARE TO BE BUSHED. ALL PENETRATIONS ARE TO BE SEALED IN
ACCORDANCE WITH CONTRACT SPECIFICATIONS. ALL CONDUIT SLEEVES ARE TO
BE BONDED TO THE TELECOMMUNICATIONS GROUNDING AND BONDING SYSTEM
PER TYPICAL TELECOM METALLIC CONDUIT BONDING DETAIL.
9. PROVIDE 18" WIDE LADDER RACK/CABLE TRAY. CABLE TRAY SHALL BE SECURED
TO WALL OR SECURELY SUSPENDED FROM CEILING STRUCTURE. PROVIDE
LENGTH AND QUANTITY PER PLANS.
10. LABEL BREAKER WITH RED NAMEPLATE “FIRE ALARM CONTROL PANEL”. LABEL
FIRE ALARM CONTROL PANEL WITH CIRCUIT NUMBER SERVING IT. PROVIDE
BREAKER LOCK FOR CIRCUIT BREAKER.
SCALE: 1/2" = 1'-0"E-500
2 ENLARGED DATA 213.1
No. 32283
R T
PROFESSIONAL
OE
G
G I A
NE E
R
IG
N E
SIGE
R
ERE
D
O.
Y
W
E O
L
M
S
M
E
A
W
C
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .