s1600 Structural Access Cuts.pdf

PDF 13 KB Posted

Attached to
FY2018 DOCKSIDE REPAIRS TO NOAA SHIP GORDON GUNTER
Solicitation number
EA133M18RP0026
Issued by

About this file

REFERENCE DOCUMENT 20 of 29

View the file

Other files

File Type Posted
528-6233903_Plumbing_Drains_Main_Deck_&_Below_(1).pdf PDF
Amendment_0004.pdf PDF
0000214_E_Plumbing_Draing_&_Sewage_Sys_Dia_T-AGOS_1_Class.pdf PDF
528-6233893_Plumbing_Drains_Above_Main_Deck.pdf PDF
CHwiring.pdf PDF
T9593-A6-MMO-010_0_A_Sewage_Lift_Station_Onmipure.pdf PDF
Rixson_Model_0600K_Pull_Side_Mounting_Instruction.pdf PDF
528-6233824_Plumbing_Drains_&_Sewage_System_Diagram.pdf PDF
Amendment_0003,_SF30_1.pdf PDF
Amendment_P002.pdf PDF
Amendment_0001,_SF30.pdf PDF
GU-555-001--.pdf PDF
512-6233797.pdf PDF
GU-436-6233675.pdf PDF
NOAA_Weight_Reporting_Spreadsheet.xlsx XLSX spreadsheet
GU-512-002.pdf PDF
NOAA Ship Gordon Gunter Drawing Index List.xlsx XLSX spreadsheet
573-1C Weight Handling Gear Testing.pdf PDF
573-2, Overhaul-Repair of Hydraulic Cylinders.pdf PDF
ATTACHMENT_J.4_Past_Performance_Questionnaire.doc DOC document
ATTACHMENT_J.5_U_S_DOL_POSTER.pdf PDF
512-6233792.pdf PDF
085-6233560 General Arrangement Main Deck and Below.pdf PDF
634-1B_DECK COVERINGS.pdf PDF
SeaClear - Typical Window Seal.pdf PDF
085-6233567 General Arrangement Fcsle Dk _ Above.pdf PDF
ASHRAE Standard 151 - HVAC Balancing _ Testing.pdf PDF
ATTACHMENT_J.2__Optional_Form_(OF)_17-BidProposal_Envelope_Label.pdf PDF
RFP.pdf PDF
ATTACHMENT_J.1_GU_FY18_DS_Spec.pdf PDF
MOC-631-2D, Coating Systems for Steel Surfaces.pdf PDF
MSD Model 12 M1-1.pdf PDF
s2906 Arc Welding on Waterborne Vessels.pdf PDF
AMC-583-1B General Requirements for Liferaft Inspections.pdf PDF
555-6233815.pdf PDF
ATTACHMENT_J.3_Past_Performance_Information_Form.docx DOCX document
512-6233800.pdf PDF
GU-512-004 Revision A.pdf PDF
GU-512-6233799 Revision B.pdf PDF
GU-512-6233801.pdf PDF
MOC-000-1G General Requirements for Ship Repair Work on NOAA Ships.pdf PDF
GU-085-6233567.pdf PDF
MOC-510-1B,_HVAC_Cleaning_(3_sheets)_(1).pdf PDF
GU-512-003 Revision B.pdf PDF
GU-512-6233802.pdf PDF
Show all 45

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

August, 1994

NOAA Standard Specification - S1600

STRUCTURAL ACCESS CUTS

1. INTENT

1.1 The intent of this item is to provide guidelines for making temporary access cuts in structural members.

2. REFERENCES

2.1 None

3. GOVERNMENT FURNISHED MATERIAL

3.1 None

4. REQUIREMENTS

4.1 Openings cut temporarily in structural members for the

purpose of providing access will be allowed only with prior approval of the COTR. Such cuts will generally be considered only where essential for access to otherwise inaccessible areas or where necessary for the removal or installation of equipment.

However, the following guidance is applicable regardless of the circumstances.

4.2 The Contractor must provide the COTR with documentation of the proposed structural opening in the form of a sketch, dimensioned and to scale, of the proposed access cut, adjacent framing members, nearby penetrations in existence, and scantlings of affected structure. It shall also provide a description of the eventual restoration of the structure to its original configuration, including materials and welding details. A narrative justification for cutting the opening shall also appear on the sketch. (Note that a mere submittal of this sketch does not assure that approval of the cut will be forthcoming. The COTR's return to the Contractor of a signed copy of the sketch constitutes approval of the proposal.)

4.3 All access cuts shall be smooth-edged (such as achieved by flame-cutting with a template), with corner radii no less than one-eighth of the transverse dimension of the opening (cuts in vertical fore-and-aft structure shall have corner radii no less than one-eight of the vertical dimension). Restoration of structure shall utilize full-penetration welding from both sides.

One-side, full penetration welding using backing bars is acceptable where access to both sides of the weld is not possible.

Structural Access Cuts S1600

5. TESTS/REPORTS/INSPECTIONS

5.1 Welds in principal structure (defined as all water-tight

structure, all structural decks and bulkheads, and framing of all these) at or below the "E" deck level shall be dye-penetrant inspected for surface cracks and the test witnessed by the COTR.