DUIS_Bugle Post Treatment.xlsx
XLSX spreadsheet 13 KB Posted
- Solicitation number
- 1149582
- Issued by
-
Department of Agriculture Forest Service
About this file
The file is a detailed unit information sheet for the PCRD Bugle Post Treatment Thinning/Fuels Reduction project, prepared by the Department of Agriculture Forest Service's Prairie City Ranger District. The document outlines 12 specific treatment units (BUGLE TS UNITS 3, 4, 6, 8, 138, 139, 145, 148, 173, 266, 299) ranging from 30 to 317 acres, located in T 16S R 34E with consistent geographic and vegetation characteristics. Each unit requires thinning and/or thinning and pile treatments with specific parameters: 20x20 spacing, 0-50% slope, elevations between 5,400-6,200 feet, and targeting tree species including WP, WL, PP, DF, ES, WF, and LP.
The treatment specifications are uniform across units, with a maximum diameter at breast height (DBH) cut limit of 9", a minimum cut tree height of 12", and a consistent instruction to pull back 6' from any fences. The document includes four optional treatment areas (Units 84, 148, 173, and 299), providing flexibility in the project's scope. The primary treatment methods are thinning and thinning with grapple pile, aimed at managing forest vegetation and reducing fuel loads in the specified geographical area.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| conroycliff_update.pdf | ||
| UnitMapwithRoads_update.pdf | ||
| KTR Solicitation Questions - Answers.docx | DOCX document | |
| DUIS_Bugle Post Treatment_update.xlsx | XLSX spreadsheet | |
| Bugle TS unit 138.pdf | ||
| Bugle TS unit 148.pdf | ||
| Bugle TS unit 266.pdf | ||
| Bugle TS unit 6.pdf | ||
| Bugle TS unit 8.pdf | ||
| Bugle TS Vicinity Map.pdf | ||
| r6_fs_6300_52-FireProtectionSupression.pdf | ||
| Bugle TS unit 173.pdf | ||
| Bugle TS unit 86.pdf | ||
| Bugle TS unit 145.pdf | ||
| Bugle TS Vicinity Map 2.pdf | ||
| 20150413-contractor-representative.doc | DOC document | |
| Bugle TS unit 299.pdf | ||
| A1 Attachment 6 Additional Fire Precautionary Measure 2 Communications.pdf | ||
| 1240BK25Q0088.pdf | ||
| Bugle TS unit 84.pdf | ||
| Bugle TS contract map.pdf | ||
| Bugle TS unit 139.pdf | ||
| Bugle TS unit 3.pdf |
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| DETAILED UNIT INFORMATION SHEET | PCRD Bugle Post Treatment Thinning/Fuels Reduction | |||||||||||||
| Item | Unit Name Number | Acres | Legal | Spacing | Slope% | Aspect | Elevation | Alternate Leave Species Preference 1/ 3/ | Current Species Composition | Max DBH Cut Limit | Min Cut Tree Hgt | Max Cull Tree DBH | Fuels Treatment | Additonal Information from footnotes |
| 1 | BUGLE TS UNIT 3 | 35 | T 16S R 34E | 20X20 +/-5' | 0-30% | E/SE | 6200 | WP, WL, PP, DF, ES, WF, LP | WL,PP,DF,WF,LP,ES | 9" | 12'' | 12" | Thinning | 6' Pull back from any fences |
| 2 | BUGLE TS UNIT 6 | 56 | T 16S R 34E | 20X20 +/-5' | 0-30% | E/SE | 5400 | WP, WL, PP, DF, ES, WF, LP | WL,PP,DF,WF,LP,ES | 9" | 12'' | 12" | Thin& pile | 6' Pull back from any fences |
| 3 | BUGLE TS UNIT 8 | 54 | T 16S R 34E | 20X20 +/-5' | 0-50% | East | 5450 | WP, WL, PP, DF, ES, WF, LP | WL,PP,DF,WF,LP,ES | 9" | 12'' | 12" | Thin& pile | 6' Pull back from any fences |
| 4 | BUGLE TS UNIT 138 | 38 | T 16S R 34E | 20X20 +/-5' | 0-40% | E/SE | 6100 | WP, WL, PP, DF, ES, WF, LP | WL,PP,DF,WF,LP,ES | 9" | 12'' | 12" | Thinning | 6' Pull back from any fences |
| 5 | BUGLE TS UNIT 139 | 60 | T 16S R 34E | 20X20 +/-5' | 0-50% | East | 5900 | WP, WL, PP, DF, ES, WF, LP | WL,PP,DF,WF,LP,ES | 9" | 12'' | 12" | Thinning | 6' Pull back from any fences |
| 6 | BUGLE TS UNIT 145 | 45 | T 16S R 34E | 20X20 +/-5' | 0-30% | East | 5450 | WP, WL, PP, DF, ES, WF, LP | WL,PP,DF,WF,LP,ES | 9" | 12'' | 12" | Thin& pile | 6' Pull back from any fences |
| 7 | BUGLE TS UNIT 266 | 161 | T 16S R 34E | 20X20 +/-5' | 0-50% | East | 5600 | WP, WL, PP, DF, ES, WF, LP | WL,PP,DF,WF,LP,ES | 9" | 12'' | 12" | Thin& pile | 6' Pull back from any fences |
| Option # 1 | ||||||||||||||
| 8 | BUGLE TS UNIT 84 | 317 | T 16S R 34E | 20X20 +/-5' | 0-50% | East | 5900 | WP, WL, PP, DF, ES, WF, LP | WL,PP,DF,WF,LP,ES | 9" | 12'' | 12" | Thin& pile | 6' Pull back from any fences |
| Option # 2 | ||||||||||||||
| 9 | BUGLE TS UNIT 4 | 31 | T 16S R 34E | 20X20 +/-5' | 0-50% | E/SE | 5800 | WP, WL, PP, DF, ES, WF, LP | WL,PP,DF,WF,LP,ES | 9" | 12'' | 12" | Thinning | 6' Pull back from any fences |
| 10 | BUGLE TS UNIT 148 | 30 | T 16S R 34E | 20X20 +/-5' | 0-30% | East | 6150 | WP, WL, PP, DF, ES, WF, LP | WL,PP,DF,WF,LP,ES | 9" | 12'' | 12" | Thinning | 6' Pull back from any fences |
| Option # 3 | ||||||||||||||
| 11 | BUGLE TS UNIT 173 | 237 | T 16S R 34E | 20X20 +/-5' | 0-50% | E/SE | 6000 | WP, WL, PP, DF, ES, WF, LP | WL,PP,DF,WF,LP,ES | 9" | 12" | 12" | Thinning | 6' Pull back from any fences |
| Option # 4 | ||||||||||||||
| 12 | BUGLE TS UNIT 299 | 181 | T 16S R 34E | 20X20 +/-5' | 0-40% | East | 5800 | WP, WL, PP, DF, ES, WF, LP | WL,PP,DF,WF,LP,ES | 9" | 12'' | 12" | Thinning | 6' Pull back from any fences |
File details come from the government source that posted it. Updated .