Owner Architect
Set Number _________
7/15/2014
CARSR / BEACON 5 & 6 RELOCATION
PROJECT
FEDERAL AVIATION ADMINISTRATION
7900 W McLUCAS ST OKLAHOMA CITY, OKLAHOMA
VOLUME 1
FEDERAL AVIATION
ADMINISTRATION
A&E DIVISION, AMP-400
(405) 954-0313
LWPB ARCHITECTURE
5909 NW EXPRESSWAY, STE 600
OKLAHOMA CITY, OK 73132
(405) 722-7270 Job Number: 13-1248-G192B
Date: JULY 15, 2014
ELECTRICAL ENGINEER
STRUCTURAL ENGINEER
CIVIL ENGINEER
PAULSGROVE ENGINEERING
2510 NW 31ST STREET
NEWCASTLE, OK 73065
(405) 830-4788
KFC ENGINEERING
205 NW 63RD ST, STE 390
OKLAHOMA CITY, OK 73116
(405) 528-4596
ALVINE ENGINEERING
13431 BROADWAY EXT, STE 101
OKLAHOMA CITY, OK 73114
(405) 936-3480
MACARTHUR ASSOCIATED CONSULTANTS
3033 NW 63RD ST, STE 250E
OKLAHOMA CITY, OK 73116
(405) 848-2471
MECHANICAL ENGINEER
RCDD
MATERIALS LEGEND SYMBOLS LEGEND ABBREVIATIONS
COMPLETE LISTING OF MATERIALS ON THE JOB.
STANDARD AND ARE NOT INTENDED AS A
NOTE: ABOVE MATERIAL INDICATIONS ARE
( DISCONTINUOUS MEMBER )
( CONTINUOUS MEMBER )
MISCELLANEOUS METAL
RIGID INSULATION BOARD
EARTH FILL
BATT INSULATION
ALUMINUM
FINISH WOOD
WOOD BLOCKING
WOOD FRAMING
INSULATED PANEL
PLYWOOD
LARGER SCALE DETAIL MARK
WALL SECTION CUT MARK
BUILDING SECTION CUT MARK
STRUCTURAL GRID COORDINATES
DOOR NUMBER
SQUARE CONCRETE COLUMN
WIDE FLANGE STEEL COLUMN
SQUARE STEEL COLUMN
ROUND STEEL COLUMN
SOUND TREATED PARTITION
FRAME PARTITION ( METAL STUD )
CONCRETE BLOCK
FOR PLANS AND DETAILS
GYPSUM BOARD
CONCRETE
FACE BRICK
EXISTING BUILDING TO BE MODIFIED
EXISTING BUILDING TO BE REMOVED
EXISTING BUILDING TO REMAIN
BENCHMARK / SPOT
ELEVATION
FINISH GRADE CONTOUR
EXISTING TREE TO BE PROTECTED
EXISTING GRADE CONTOUR
EXISTING TREE TO BE REMOVED
PROPERTY LINE
PAVING ( CONCRETE )
PAVING ( ASPHALT )
CONCRETE WALK
TEST HOLE
NEW BUILDING
FENCEXX
15' OAK
18' ELM
EXISTING SPOT ELEVATION
FINISH SPOT ELEVATION
100.25
X
FRAME ELEVATION
PARTITION TYPE
ROOM NAME AND NUMBER
INTERIOR
ELEVATION REF.
SIM
A102A108
SIM
A102A108
1 SIM
A102 A103
DETAIL SECTION CUT MARK1 SIM
A102A108
Room name
1t
NORTH ARROW SYMBOLS
PLAN
NORTH
TRUE
NORTH
FOR DETAILS
SHEET WHERE
ELEV IS DRAWN
ELEV INDICATED
A5.1
EXTERIOR
ELEVATION REF.SHEET WHERE
ELEV IS DRAWN
ELEV INDICATED
A5.1
REF.
CASEWORK
SECTION
SHEETS
CASEWORK
SECTION
IDENTIFICATION
NUMBER512
1i
AB ABOVE
ADJ ADJUSTABLE
AFF ABOVE FINISH FLOOR
ALUM ALUMINUM
APPROX, APPAPPROXIMATELY
ATFP, AT/FP ANTI-TERRORISM/FORCE PROTECTION
AWC ACOUSTICAL WALL COVERING
BLDG BUILDING
BM BENCH MARK
BRG BEARING
BTM BOTTOM
C CENTERLINE
CJ CONTROL JOINT
CLG CEILING
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DN DOWN
DTL DETAIL
DWR DRAWER
EJ, EXP JT EXPANSION JOINT
ELEC ELECTRICAL
ELEV ELEVATION
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXT EXTERIOR
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEB FIRE EXTINGUISHER BRACKET
FEC FIRE EXTINGUISHER CABINET
FF, FIN FLR FINISH FLOOR
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIO FOR INFORMATION ONLY
F FLOW LINE
GA GAUGE
GI GALVANIZED IRON
GWB, GYP BD GYPSUM BOARD
HC, HDCP HANDICAPPED (ACCESSIBLE)
HD HEAD
HDWR HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HT HEIGHT
INSUL INSULATION
INT INTERIOR
JST JOIST
JT JOINT
LAM LAMINATE
LAV LAVATORY
LP LIGHT POLE
MATL MATERIAL
MAX MAXIMUM
MB MARKER BOARD
MECH MECHANICAL
MFR, MFG MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
NIC NOT IN CONTRACT
NO NUMBER
NTS NOT TO SCALE
OC ON CENTER
OPNG OPENING
OPP OPPOSITE
PL PLATE
PLYWD PLYWOOD
R RADIUS OR RISER
RE:, REF REFER
REINF REINFORCING / REINFORCED
REQD REQUIRED
RI ROUGH IN
RM ROOM
RO ROUGH OPENING
SB SMART BOARD
SC SOLID CORE
SCHED SCHEDULE / SCHEDULED
SIM SIMILAR
SJ SCORED JOINT
SPECS SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
SSCG STAINLESS STEEL CORNER GUARD
STL STEEL
STRUCT STRUCTURAL
T TREAD
TB TACK BOARD
TOC TOP OF CURB
TOM TOP OF MASONRY
TOS TOP OF STEEL
TOW TOP OF WALL
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
WC WATER CLOSET
WD WOOD
ADDITIONAL SYMBOLS/ABBREVIATIONS NOT SHOWN OR
DEFINED WITHIN THIS SHEET MAY OCCUR AND ARE
DEFINED ON OTHER DRAWINGS.
L
SIM
A102A108
SHEET WHERE DETAIL
IS DRAWN
DETAIL INDICATED
SHEET WHERE DETAIL
IS FIRST REFERENCED
EXISTING WALL (NOT USED)
GYPSUM SHEATHING
DRAWING INDEX
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT SCALE:
DRAWING NO. AMP-400-E-
LO
C
A L
FI
LE
P
LO
T D
A
TE
LW
P B
J O
B N
O
C E
N
TR
A L
FI
LE
A
B
C
D
E
F
G
A
B
C
D
E
F
G
TE
M
P
LA
T E
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S.
government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
ISSUED BY
OFFICE OF:
FACILITY MANAGEMENT
AMP-400
PROJECT MANAGER:
CYNTHIA HURD, AMP-400
WORK REQUEST NO:
CARSR / ASR 1/2 TRAINING CENTER
7/15/2014
12" = 1'-0"
C :\U se rs
\b w in te rs ch ei d t\D oc um en ts \F
A A
C A
R S
R R
A D
A R
C E
N
TE
R A
R C
H
IT
E C
TU
R
A L_
B W in te rs ch ei d t.r vt
8/
/2
5:
:1
P
M
CARSR / BEACON 5 & 6 RELOCATION PROJECT
7900 W McLUCAS ST OKLAHOMA CITY, OKLAHOMA
DRAWING INDEX, SYMBOLS, AND
ABBREVIATIONS
G1.1ERIC SILER
WINTERSCHEIDT
2013-007862
-1
8-
G
2B
\\l w p b
-f ile sr vr
\F ed er al
FA
A \F
A A
ID
IQ
\T
O
Ty p e B s er vi ce
C A
R S
R \0
D w g s\
FA
A C
A R
S R
R A
D A
R C
E N
TE
R
A R
C H
IT
E
C
TU
R A
L.
rv t
LW
P
B
3.
0 4
U p d at ed to .0
JULY 15, 2014
CYNTHIA HURD, AMP-400
2013-007862
NUMBER NAME
E2.1 POWER PLAN
E2.2 ROOF POWER PLAN
E2.3 ENLARGED POWER PLAN - NE
AREA AND STORAGE BUILDING
E2.4 ENLARGED PLANS AND
ELEVATIONS - BREAKROOM
E2.5 POWER DETAILS
E3.1 LIGHTING PLAN
E3.2 LIGHTING DETAILS
E4.1 GROUNDING PLAN - CARSR
TRAINING FACILITY
E4.2 GROUNDING PLAN - RADAR
TOWER
E4.3 ENLARGED GROUNDING PLAN -
NE AREA
E4.4 GROUNDING SYSTEM DIAGRAM
AND DETAILS
E4.5 GROUNDING DETAILS
E4.6 GROUNDING DETAILS
E5.1 LIGHTNING PROTECTION PLAN
E5.2 LIGHTNING PROTECTION
DETAILS
E5.3 LIGHTNING PROTECTION
DETAILS
E5.4 LIGHTNING PROTECTION
DETAILS
E6.1 MEDIUM VOLTAGE SINGLE-LINE
DIAGRAMS
E6.2 SINGLE-LINE DIAGRAM
E6.3 PANELBOARD SCHEDULES
E6.4 PANELBOARD SCHEDULES
E6.5 PANELBOARD SCHEDULES
E6.6 ELECTRICAL SCHEDULES
E6.7 LIGHTING SCHEDULES
FIRE ALARM
FA0.0 FIRE ALARM LEGEND,
ABBREVIATION AND GENERAL
REQUIREMENTS
FA1.0 FIRE ALARM PLAN
FA1.1 FIRE ALARM DETAILS
TELECOMMUNICATIONS
T0.0 TELECOM SYMBOLS AND
ABBREVIATIONS
T0.1 TELECOM SCHEMATICS
T0.2 TELECOM SITE PLAN
T1.1 FLOOR PLAN - TELECOM
T2.1 TELECOM ENLARGED PLAN
T4.1 TELECOM DETAILS
T4.2 TELECOM SITE DETAILS
T4.3 TELECOM SITE DETAILS
PA1.1 FLOOR PLAN - PUBLIC ADDRESS
SECURITY
SC1.1 FLOOR PLAN - SECURITY
SC2.1 SECURITY DETAILS
NUMBER NAME
A9.3 VERTICAL DETAILS
A9.4 VERTICAL DETAILS
A9.5 CEILING DETAILS
A9.6 TYPICAL ROOF DETAILS
STRUCTURAL
S1.1 GENERAL NOTES
S1.2 GENERAL NOTES
S1.3 TYPICAL FOUNDATION DETAILS
S1.4 TYPICAL CMU DETAILS
S1.5 TYPICAL STEEL DETAILS
S1.6 TYPICAL STEEL JOIST DETAILS
S2.1 FOUNDATION PLAN
S2.2 STORAGE PLANS AND SECTIONS
S2.3 CANOPY PLANS AND SECTIONS
S3.1 ROOF FRAMING PLAN
S3.2 SHELTER FRAMING
S4.1 FRAMING ELEVATIONS
S4.2 FRAMING ELEVATIONS
S5.1 FOUNDATION SECTIONS
S5.2 FOUNDATION SECTIONS
S6.1 FRAMING SECTIONS
S6.2 FRAMING SECTIONS
FIRE PROTECTION
FP1.1 FLOOR PLAN - FIRE PROTECTION
MECHANICAL
M0.0 MECHANICAL SYMBOLS
M0.1 MECHANICAL SITE PLAN
M1.1 FLOOR PLAN - HVAC
M2.1 FLOOR PLAN - HVAC PIPING
M3.1 MECHANICAL DETAILS
M3.2 MECHANICAL DETAILS
M3.3 MECHANICAL DIAGRAM
M4.1 MECHANICAL SCHEDULES
PLUMBING
P1.1 UNDERFLOOR PLAN - PLUMBING
P1.2 FLOOR PLAN - PLUMBING
P1.3 ROOF PLAN - PLUMBING
P2.1 PLUMBING ENLARGED PLAN
P3.1 PLUMBING DETAILS
P4.1 PLUMBING SCHEDULES
ELECTRICAL
E0.0 LEGEND, ABBREVIATIONS AND
GENERAL REQUIREMENTS
E1.0 ELECTRICAL SITE PLAN
E1.1 ENLARGED SITE PLANS
E1.2 ENLARGED SITE PLAN - CARSR
BUILDING
E1.3 ELECTRICAL SITE DETAILS
E1.4 ELECTRICAL SITE DETAILS
E1.5 ELECTRICAL SITE DETAILS
E1.6 ELECTRICAL SITE DETAILS
E1.7 ELECTRICAL SITE LIGHTING
DETAILS
NUMBER NAME
GENERAL
G0.0 COVER SHEET
G1.1 DRAWING INDEX, SYMBOLS, AND
ABBREVIATIONS
G1.2 GENERAL NOTES
G1.3 MOUNTING HEIGHTS, LOCATIONS
AND CONFIGURATIONS
G1.4 ACCESSIBILITY REQUIREMENTS
G1.5 BUILDING CODE CRITERIA
SUMMARY
G2.1 TORNADO SHELTER PLAN
CIVIL
C1.0 GENERAL NOTES & CIVIL LEGEND
C2.1 GENERAL LAYOUT PLAN
C2.2 SITE LAYOUT PLAN
C2.3 SITE UTILITY PLAN
C2.4 GRADING PLAN
C2.5 ELEVATION CONTROL PLAN
C2.6 JOINT LAYOUT PLAN
C2.7 SIDEWALK JOINT LAYOUT PLAN
C2.8 ROADWAY PLAN & PROFILE
C2.9 EROSION CONTROL PLAN
C3.1 TYP. PAVEMENT SECTION &
MISC. DETAILS
C3.2 PAVING JOINT DETAILS
C3.3 MISCELLANEOUS DETAILS I
C3.4 MISCELLANEOUS DETAILS II
C3.5 MISCELLANEOUS DETAILS III
C3.6 MISCELLANEOUS DETAILS IV
C3.7 EROSION CONTROL DETAILS
ARCHITECTURAL
A1.1 ARCHITECTURAL SITE ELEMENTS
A1.2 ARCHITECTURAL SITE DETAILS
A2.1 FLOOR PLAN
A2.2 ENLARGED PLANS
A2.3 NOT USED
A2.4 DOOR SCHEDULE AND DOOR
ELEVATIONS
A2.5 FRAME ELEVATIONS
A2.6 AIR BARRIER PLAN
A2.7 AIR BARRIER DETAILS
A2.8 FINISH MATERIAL COLOR
SCHEDULE
A2.9 ROOM FINISH SCHEDULE
A2.10 INTERIOR FINISH PLAN
A2.11 FFE COORDINATION PLAN
A2.12 FURNITURE PLANS - BY AREA
A2.13 SIGNAGE PLAN
A2.14 SIGNAGE SCHEDULE AND
DETAILS
A3.1 REFLECTED CEILING PLAN
A3.2 REFLECTED CEILING PLANS AND
DETAILS
A4.1 ROOF PLAN
A4.2 ROOF PLAN
A5.1 BUILDING ELEVATIONS
A5.2 BUILDING ELEVATIONS
A6.1 INTERIOR PARTITION TYPE
DIAGRAMS
A6.2 INTERIOR PARTITION TYPE
SCHEDULE AND DETAILS
A6.3 BUILDING SECTIONS
A6.4 BUILDING SECTIONS
A6.5 WALL SECTIONS
A6.6 WALL SECTIONS
A6.7 WALL SECTIONS
A6.8 WALL SECTIONS
A7.1 INTERIOR ELEVATIONS
A7.2 INTERIOR ELEVATIONS
A7.3 INTERIOR ELEVATIONS
A7.4 INTERIOR ELEVATIONS
A7.5 CASEWORK SECTIONS
A7.6 MISCELLANEOUS INTERIOR
DETAILS
A7.7 MISCELLANEOUS INTERIOR
DETAILS
A8.1 PLAN DETAILS
A8.2 PLAN DETAILS
A8.3 PLAN DETAILS
A9.1 VERTICAL DETAILS
A9.2 VERTICAL DETAILS
SYMBOL DESCRIPTION DATE APPR
1. TOPOGRAPHIC SURVEY BY MACARTHUR ENGINEERING CONSULTANTS, INC. REFER
TO CIVIL DRAWINGS.
2. AN ATTEMPT HAS BEEN MADE TO LOCATE AND SHOW ON THE DRAWINGS
EXISTING UNDERGROUND UTILITIES AND OTHER EXISTING SITE CONDITIONS,
HOWEVER, THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSPECTING THE SITE AND
VERIFYING ALL EXISTING UTILITIES AND CONDITIONS AT THE SITE PRIOR TO THE START
OF CONSTRUCTION, AND SHALL REPORT ANY DISCREPANCIES TO THE ARCHITECT FOR
CLARIFICATION BEFORE PROCEEDING WITH THE WORK.
3. CONSTRUCTION STAGING AREA & VEHICLE ACCESS SHALL BE CONFIRMED WITH
OWNER, AND CONSTRUCTION MANAGER IF APPLICABLE, PRIOR TO CONSTRUCTION.
4. FINISH GRADE AT BUILDING PERIMETERS SHALL BE 6" BELOW FINISH FLOOR
UNLESS SPECIFICALLY NOTED OTHERWISE ON CIVIL DRAWINGS. DEVELOP POSITIVE
DRAINAGE AWAY FROM NEW AND/OR EXISTING BUILDING(S).
5. ALL AREAS OF THIS SITE, WHICH ARE NOT IN THE SCOPE OF THE PROJECT AND
ARE DISTURBED BY CONSTRUCTION, SHALL BE RETURNED TO ORIGINAL CONDITION.
6. ALL GRID LINES IDENTIFIED BY A LETTER OR NUMBER ARE PARALLEL AND
ORTHOGONAL UNLESS OTHERWISE NOTED.
7. CONTRACTOR SHALL VERIFY ALL COLUMN COORDINATES AND CHECK THEM
AGAINST DIMENSIONS SHOW ON PLANS AND DETAILS. NOTIFY ARCHITECT OF ANY
DISCREPENCY DURING STAKING.
8. SIZES OF HOUSEKEEPING PADS AND BASES FOR MECHANICAL EQUIPMENT ARE
APPROXIMATE. CONTRACTOR SHALL VERIFY EXACT LOCATION AND REQUIRED SIZE OF
ALL CONCRETE PADS AND BASES WITH EQUIPMENT MANUFACTURERS BEFORE
POURING. ALL PADS TO BE PROVIDED BY THE CONTRACTOR.
9. CONTRACTOR SHALL COORDINATE THE INSTALLATION OF THE VARIOUS TRADE
ITEMS WITHIN THE SPACE ABOVE THE CEILINGS (INCLUDING, BUT NOT LIMITED TO
STRUCTURAL MEMBERS AND SPRAY-ON INSULATION OR FIREPROOFING, MECHANICAL
DUCTS AND BATT INSULATION, CONDUITS, RACEWAY, SPRINKLER SYSTEMS, LIGHT
FIXTURES, CEILING SYSTEMS, AND ANY SPECIAL STRUCTURAL SUPPORTS REQUIRED)
AND SHALL BE RESPONSIBLE FOR MAINTAINING THE FINISH CEILING HEIGHT ABOVE
THE FINISH FLOOR INDICATED IN THE DRAWINGS AND FINISH SCHEDULE.
10. ALL METAL STUD WALLS WHERE PLUMBING OCCURS OR STRUCTURAL COLUMNS
ARE LOCATED SHALL BE MINIMUM 6" METAL STUDS. NOTIFY ARCHITECT OF ANY
DISCREPANCIES OR CONFLICTS.
11. PROVIDE AND INSTALL ACCESS PANELS, WHERE REQUIRED BY BUILDING CODE OR
FOR THE PROPER OPERATION OF MECHANICAL OR ELECTRICAL EQUIPMENT, AND AS
SHOWN ON THE DRAWINGS. CONTRACTOR SHALL COORDINATE SIZE, LOCATION, AND
TYPE OF ACCESS PANEL WITH OTHER CONTRACTORS' WORK AND RECEIVE APPROVAL
OF THE ARCHITECT. ACCESS PANEL SHALL BE AS SPECIFIED.
12. 3/4" FIRE-RETARDANT TREATED PLYWOOD BACKING 8'-0" HIGH SHALL BE PROVIDED
AND INSTALLED ON ALL WALLS OF TELEPHONE AND ELECTRICAL ROOMS AS REQUIRED
UNLESS SPECIFICALLY SHOWN OTHERWISE ON ELECTRICAL DRAWINGS.
13. ALL WOOD WITHIN THIS PROJECT (I.E. PLYWOOD, BLOCKING, ETC.) SHALL BE FIRE-
RETARDANT TREATED.
14. THE ARCHITECTURAL FLOOR PLANS, REFLECTED CEILING PLANS, SECTIONS, AND
ELEVATIONS SHOW THE EXACT LOCATION OF MANY, BUT NOT ALL, EXPOSED PARTS OF
THE WORK. FOR TYPICAL DIMENSIONING CONVENTIONS, INCLUDING RULES FOR
LOCATING DOORS AND OTHER ITEMS NOT WHICH HAVE NOT BEEN DIMENSIONED OR
LOCATED EXACTLY, APPLY THE RULES INDICATED BY THE "RULES AND CONVENTIONS"
SHEET TO DETERMINE THE EXACT LOCATION OF EACH EXPOSED PART OF THE WORK.
15. FOR ILLUSTRATION AND DEFINITION OF TYPICAL SYMBOLS USED ON THE
ARCHITECTURAL DRAWINGS, SEE “ARCHITECTURAL DIMENSIONING CONVENTIONS” ON
THIS SHEET. ADDITIONAL SYMBOLS NOT SHOWN OR DEFINED THERE MAY OCCUR AND
ARE DEFINED ON OTHER DRAWINGS.
16. DO NOT SCALE THE DRAWINGS TO OBTAIN DIMENSIONS.
17. REFER TO SPECIFICATIONS FOR ADDITIONAL PAINT ITEMS NOT SHOWN ON ROOM
FINISH SCHEDULE.
18. HAZARDOUS MATERIALS INCLUDING, BUT NOT LIMITED TO, ASBESTOS, MATERIALS
CONTAINING ASBESTOS, POLYCHLORINATED BIPHENYL (PCB) OR OTHER TOXIC
SUBSTANCES SHALL NOT BE CONTAINED IN MATERIALS AND/OR PRODUCTS USED IN
THE CONSTRUCTION OF THIS PROJECT.
19. IN THE CASE OF A CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONS, THE
MORE RESTRICTIVE OF THE TWO SHALL GOVERN. CONTRACTOR SHALL NOTIFY THE
ARCHITECT OF ANY CONFLICT BEFORE PROCEEDING WITH THE WORK.
20. EVERY EFFORT HAS BEEN MADE TO COORDINATE THE DRAWINGS AND
SPECIFICATIONS, AND TO ELIMINATE DISCREPANCIES BETWEEN THEM. IT SHALL BE
THE CONTRACTOR'S RESPONSIBILITY TO BRING ANY DISCREPANCIES OR CONFLICTS
TO THE ARCHITECT'S ATTENTION FOR CLARIFICATION. IMPROPERLY INSTALLED WORK
SHALL BE CORRECTED BY THE CONTRACTOR AT NO EXPENSE TO THE ARCHITECT, HIS
CONSULTANTS, OR THE OWNER.
GENERAL NOTES: ARCHITECTURAL DIMENSIONING CONVENTIONS
1. EXCEPT WHERE DIRECTED TO PLACE ITEMS OF THE
WORK AT THE "APPROXIMATE LOCATION SHOWN," DO
NOT SCALE THE DRAWINGS FOR DIMENSIONAL
INFORMATION.
2. ALL ELEMENTS OF THE DRAWINGS MAY NOT BE DRAWN
TO EXACT SCALE. ALL DIMENSIONS REQUIRED ARE
SHOWN (OR MAY BE DERIVED FROM THOSE SHOWN OR
NOTED) ONT HE FLOOR PLANS, DETAIL PLANS,
ELEVATIONS, SECTIONS, SCHEDULES, CONFIGURATION
DETAILS AND SPECIFICATIONS. SEE THE NOTES BELOW
AND "SYMBOLS AND ABBREVIATIONS" SHEET FOR
DIMENSIONING, GRAPHIC AND OTHER TYPICAL
CONVENTIONS USED ON THIS PROJECT.
3. EXCEPT WHERE SPECIFICALLY NOTED TO THE
CONTRARY, ALL DIMENSIONS SHOWN ON THE
ARCHITECTURAL DRAWINGS CONFORM TO THE
FOLLOWING CONVENTIONS:
A. GENERALLY, DIMENSIONS ARE MEASURED TO:
• STRUCTURAL OR DIMENSIONAL GRID LINES.
• CENTERLINE OF STUD (EXCLUSIVE OF GWB,
AND ANY APPLIED FINISHES HAVING
THICKNESS WHICH MAY BE ADDED TO SUCH
WALLS) AT PARTITIONS FRAMED WITH METAL
STUDS. REFER TO "PARTITION TYPES"
SCHEDULE TO DETERMINE THICKNESS OF
EACH PARTITION TYPE.
• FACE OF CONCRETE OR MASONRY WALL
(EXCLUSIVE OF ANY FURRING OR APPLIED
FINISHES HAVING THICKNESS WHICH MAY BE
ADDED TO SUCH WALLS) AT WALLS WITH
CONCRETE OR MASONRY COMPONENTS.
REFER TO STRUCTURAL DRAWINGS AND
"PARTITION TYPES" SCHEDULE TO DETERMINE
THICKNESS OF EACH PARTITION TYPE.
• FACE OF APPLIED FINISH IF NOTED AS A "FACE
OF FINISH" OR "CLEAR" DIMENSION. SEE NOTE
'B' BELOW.
• OUTSIDE EDGE OF HOLLOW METAL DOOR
AND WINDOW FRAMES. REFER TO THE
"DOOR SCHEDULE" AND "FRAME ELEVATIONS"
FOR ADDITIONAL DIMENSIONAL INFORMATION.
• INSIDE EDGE OF FINISHED WALL OPENING AT
OTHER DOORS, WINDOWS AND CURTAIN
WALLS. REFER TO THE "DOOR SCHEDULE"
AND "FRAME ELEVATIONS" FOR ADDITIONAL
DIMENSIONAL INFORMATION.
• DIMENSION OR WORK POINTS AS INDICATED
ON RELATED ARCH DETAIL, PLAN, SECTION,
ELEVATION, LAYOUT OR CONFIGURATION
DETAIL, OR CONSTRUCTION DETAIL.
B. WHERE "FACE OF FINISH" OR "CLEAR"
DIMENSIONS ARE SPECIFICALLY NOTED, THE
DIM IS MEASURED TO:
• FINISH FACES AT THE MOST NARROW OR
CONSTRICTED POINT OF SECTION WHERE
DIMENSION IS SHOWN, WHEN THE DIMENSION
OCCURS ACROSS AN OPEN SPACE. IN THIS
CASE, A "FACE OF FINISH" DIMENSION IS
EQUIVALENT TO A "CLEAR" DIMENSION.
• FINISH FACES AT THE WIDEST OR MOST
EXPANSIVE POINTS OF THE SECTION THE
DIMENSION IS SHOWN WHEN THE DIMENSION
OCCURS ACROSS AN OBJECT OR GROUP OF
OBJECTS.
C. WHERE "EQUAL" DIMENSIONS ARE USED:
• IN CASEWORK AND OTHER SUCH ELEMENTS,
"EQUAL" DIMENSIONS ARE NOT INTENDED TO
REQUIRE CUSTOM COMPONENTS. SUCH
"EQUAL" ELEMENTS SHALL BE THE SAME SIZE,
AT THE STANDARD SIZE INCREMENT THAT MOST
NEARLY EQUALS THE DESIGNED OVERALL
DIMENSION. IN THESE CONDITIONS, EQUAL SIZE
FILLER PANELS ARE INTENDED AND REQUIRED
AT EACH END OF THE RUN.
D. WHERE "EQUAL" DIMENSIONS ARE USED ON
REFLECTED CEILING PLANS TO LOCATE CEILING
GRID WORK POINTS, MEASURE DIMENSIONS TO:
• EDGE OF THE INDICATED CEILING AT THE FACE
OF THE ADJACENT APPLIED FINISH, MEASURED
AT THE PLANE OF THE CEILING.
• CAUTION: DUE TO THE POSSIBLE APPLICATION
OF APPLIED FINISHES (THE THICKNESS OF
WHICH MAY VARY BETWEEN FLOOR AND CEILING
AND IS NOT ACCOUNTED FOR BY THE
DIMENSIONS SHOWN ON THE FLOOR PLANS,
EXCEPT AS INDICATED BY "FACE OF FINISH" OR
"CLEAR"), THE CONTRACTOR MUST ADJUST, AS
NECESSARY, THE FLOOR PLAN DIMENSIONS TO
REFLECT THE ACTUAL DIMENSIONS FOUND AT
THE PLANE OF THE CEILING.
4. WHERE WALLS AND/OR PARTITIONS OF UNEQUAL
THICKNESS ABUT, ALIGN EXPOSED FACES, UNLESS
OTHERWISE NOTED.
5. WHERE DIMENSIONS ARE NOT PROVIDED ON FLOOR
PLANS TO LOCATE DOOR OPENINGS, APPLY THE
FOLLOWING RULES IN ORDER, TO DETERMINE THE
LOCATION OF DOOR OPENINGS:
A. DOOR OPENINGS MAY BE DIMENSIONED ON
DRAWINGS OTHER THAN THE FLOOR PLANS.
REFER TO THE SECTIONS, ELEVATIONS, DETAILS
AND DOOR SCHEDULE NOTES FOR ADDITIONAL
DIMENSIONAL INFORMATION.
B. WHERE THE HINGE-SIDE OF A DOOR IS SHOWN
ADJACENT TO A WALL, OR WALLS,
PERPENDICULAR TO THE WALL IN WHICH THE
DOOR OPENING OCCURS:
• AT DOORS OCCURRING IN METAL FRAMED
GYPSUM BOARD PARTITIONS, LOCATE THE
HINGE-SIDE OF THE DOOR FINISHED OPENING
4 INCHES FROM THE FACE (EXCLUSIVE OF
APPLIED FINISHES) OF THE CLOSEST
PERPENDICULAR WALL OR PARTITION
ASSEMBLY.
• AT DOORS OCCURRING IN WALLS OF CONCRETE
OR CONCRETE MASONRY CONSTRUCTION,
LOCATE THE HINGE-SIDE OF THE DOOR FINISHED
OPENING 10 INCHES FROM THE FACE (EXCLUSIVE
OF APPLIED FINISHES) OF THE CLOSEST
PERPENDICULAR WALL OR PARTITION
ASSEMBLY.
• IF SPACE ALLOWS, CENTER DOOR IN WALL
SHOWN ON THE DRAWINGS SO THAT
EITHER "DIM A" EQUALS "DIM C", OR
"DIM B" EQUALS "DIM D".
D. IF "DIM E" IN DIAGRAMS BELOW IS LESS THAN THE
SUM OF 2 TIMES THE DOOR WIDTH PLUS 20 INCHES,
LOCATE DOOR SO THAT MINIMUMS STATED BY
NOTE 4C ABOVE FOR "DIM A", "DIM B", AND "DIM D"
ARE MET, MAXIMIZING "DIM A" AND MINIMIZING
"DIM D" TO THE EXTENT POSSIBLE.
MEASURED AT CLG PLANE
"EQUAL" DIM AT CEILING
MEASURED TO FACE OF PTN
TYP. DIM ON CEILING PLAN
4".
4".
A E
C G
B D
F
H
E A
B D
E A D
B
ALIGN
10".
10".
21. ALL ITEMS WITHIN THESE PROJECT DOCUMENTS ARE PART OF THE BASE
BID UNLESS OTHERWISE NOTED.
22. THE ARCHITECTURAL DRAWINGS ARE A PART OF A LARGER SET OF
DRAWINGS WHICH, WHEN COMPLETE, CONSISTS OF ALL DRAWINGS LISTED BY
THE INDEX OF DRAWINGS. THE WORK DESCRIBED BY THE DRAWINGS OF ANY
ONE DISCIPLINE MAY BE AFFECTED BY THE WORK DESCRIBED ON DRAWINGS
OF ANOTHER DISCIPLINE AND MAY REQUIRE REFERENCE TO DRAWINGS OF
ANOTHER DISCIPLINE. PARTIAL SETS OF DRAWINGS SHALL NOT BE
DISTRIBUTED AND UTILIZED BY THE CONTRACTOR. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO REVIEW AND COORDINATE THE WORK OF ALL
SUBCONTRACTORS, TRADES, AND SUPPLIERS WITH THE REQUIREMENTS OF
THE CONTRACT BEFORE COMMENCING CONSTRUCTION AND TO ASSURE THAT
ALL PARTIES ARE AWARE OF ALL REQUIREMENTS, REGARDLESS OF WHERE
THE REQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS.
23. THE ARCHITECTURAL DRAWINGS ESTABLISH AND COORDINATE THE
FINISHED APPEARANCE AND EXACT LOCATIONS OF ALL EXPOSED ELEMENTS
OF THE WORK, INCLUDING THAT WORK WHICH IS ILLUSTRATED PRIMARILY ON
DRAWINGS OF OTHER DISCIPLINES. LOCATIONS SHOWN ON OTHER DRAWINGS
ARE SCHEMATIC, UNLESS OTHERWISE NOTED ON THE ARCHITECTURAL
DRAWINGS. THE ARCHITECTURAL DRAWINGS TAKE PRECEDENCE FOR THE
FINISHED APPEARANCE AND EXACT LOCATION OF ALL PARTS OF THE WORK.
[EXCEPTIONS: DIMENSIONED LOCATIONS SHOWN ON DRAWINGS OF OTHER
DISCIPLINES SHALL GOVERN ONLY WHERE: (A) SPECIFICALLY AND INDIVIDUALLY
INDICATED BY SYMBOL, KEYED NOTE, OR NOTATION ON THE ARCHITECTURAL
DRAWINGS. (B) OCCURRING WITHIN A ROOM OR OTHER IDENTIFIED SPACE FOR
WHICH ARCHITECTURAL SHEET OR SCHEDULE NOTES INDICATE THAT
DIMENSIONS PROVIDED ELSEWHERE SHALL GOVERN.]
24. PROVIDE FIRE EXTINGUISHERS WITH A RATING OF NOT LESS THAN 2A
WITHIN 75 FOOT TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING.
PROVIDE PORTABLE FIRE EXTINGUISHERS AS THE BUILDING IS CONSTRUCTED.
25. CONTRACTOR TO PROVIDE CONSTRUCTION WASTE MANAGEMENT PLAN
WITHIN 15 DAYS AFTER CONTRACT AWARD. REFER TO SIR, PART II, SECTION I,
CONTRACT CLAUSES FOR SPECIFIC REQUIREMENTS.
C. WHERE DOOR OCCURS NOT ADJACENT TO A
PERPENDICULAR WALL, AND EITHER "DIM E"
OR "DIM F" IS 16'-0" OR LESS, LOCATE DOOR
UTILIZING THE FOLLOWING MINIMUM
DIMENSIONS:
• DIMENSION A = 18 INCHES MIN
• DIMENSION B = 12 INCHES MIN
• DIMENSIONS C = DOOR WIDTH + 2 INCHES
MINIMUM
• DIMENSION D = 4 INCHES MIN AT METAL
FRAMED GYP BD PARTITIONS
• DIMENSIONS E AND F = AS SHOWN ON
PLANS
• DIMENSION G = 36 INCHES MIN
• DIMENSION H = 60 INCHES MIN
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT SCALE:
DRAWING NO. AMP-400-E-
LO
C
A L
FI
LE
P
LO
T D
A
TE
LW
P B
J O
B N
O
C E
N
TR
A L
FI
LE
A
B
C
D
E
F
G
A
B
C
D
E
F
G
TE
M
P
LA
T E
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S.
government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
ISSUED BY
OFFICE OF:
FACILITY MANAGEMENT
AMP-400
PROJECT MANAGER:
CYNTHIA HURD, AMP-400
WORK REQUEST NO:
CARSR / ASR 1/2 TRAINING CENTER
7/15/2014
12" = 1'-0"
C :\U se rs
\b w in te rs ch ei d t\D oc um en ts \F
A A
C A
R S
R R
A D
A R
C E
N
TE
R A
R C
H
IT
E C
TU
R
A L_
B W in te rs ch ei d t.r vt
7/
/2
:1 6:
P
M
CARSR / BEACON 5 & 6 RELOCATION PROJECT
7900 W McLUCAS ST OKLAHOMA CITY, OKLAHOMA
GENERAL NOTES
G1.2ETS
BMW
2013-007862
-1
8-
G
2B
\\l w p b
-f ile sr vr
\F ed er al
FA
A \F
A A
ID
IQ
\T
O
Ty p e B s er vi ce
C A
R S
R \0
D w g s\
FA
A C
A R
S R
R A
D A
R C
E N
TE
R
A R
C H
IT
E
C
TU
R A
L.
rv t
LW
P
B
3.
0 4
U p d at ed to .0
JULY 15, 2014
CYNTHIA HURD, AMP-400
2013-007862
10'-6"
TYPICAL RULES FOR DETERMINING MOUNTING HEIGHTS, LOCATIONS AND CONFIGURATIONS
GRID
C
C
RULE 1
RULE 3
RULE 7
RULE 2
RULE 5 RULE 6
RULE 4
RULE 8
WHEN COMPLETELY DIMENSIONED ON PLANS
NOT DIMENSIONED AND LOCATED ON COLUMN OR PILASTER
NOT DIMENSIONED AND LOCATED ADJ TO DOOR
AND ON WALL AGAINST WHICH DOOR SWINGS
NOT DIMENSIONED AND LOCATED ON COLUMN OR PILASTER
NOT DIMENSIONED AND LOCATED ADJ TO MIN STRIKE-SIDE OF DOOR NOT DIMENSIONED AND LOCATED ADJACENT TO DOOR (OR WINDOW)
NOT DIMENSIONED AND LOCATED ON COLUMN OR PILASTER
WHEN NOT DIMENSIONED AND LOCATED
ADJACENT TO CHANGE IN WALL DIRECTION
LOCATE ITEMS AS INDICATED WHEN SHOWN DIMENSIONED
(BOTH HORIZ AND VERT) BY A PLAN OR DETAIL PLAN.
OVER TYPICAL MOUNTING HEIGHTS AND LOCATION RULES.
SHOWN BY PLANS AND DETAIL PLANS TAKE PRECEDENCE
ELEVATIONS, OR DETAIL ELEVATIONS AND SPECIFIC HORIZ DIM
SPECIFIC VERT DIMENSIONS SHOWN BY ELEVATIONS, SECTIONAL
(AS SHOWN), BY KEYED NOTE, OR BY NOTATION ON PLANS.
NON-TYPICAL MOUNTING HEIGHTS MAY BE INDICATED BY SYMBOL
APPLIES: HORIZ CENTER GROUP OF SIMILAR ITEMS HAVING THE
WHEN APPLICABLE, COMBINE THIS RULE WITH RULE 2 (PREVIOUS)
PILASTER, AND WHEN NO OTHER TYPICAL CONFIGURATION DIAGRAM
TO SYMMETRICALLY ARRANGE GROUPS OF ITEMS HAVING BOTH
WHEN NOT DIMENSIONED AND SHOWN LOCATED ON A COLUMN OR
SAME MOUNTING HEIGHT(S) ABOUT THE CENTERLINE OF THE
APPLIES: MOUNT ITEMS IN RELATION TO SWING USING TYP OFFSET
ON SIDE OPPOSITE FRAME AS ILLUSTRATED BY THIS DIAGRAM.
DOOR, AND WHEN NO OTHER TYPICAL CONFIGURATION DIAGRAM
WHEN NOT DIMENSIONED AND SHOWN LOCATED ADJACENT TO
WHEN MULTIPLE ITEMS HAVING THE SAME TYP MOUNTING HEIGHT ARE
DIMENSION. VERTICALLY ALIGN CENTERS OF ITEMS MOUNTED AT
INDICATED, MOUNT FIRST ITEM IN RELATION TO SWING USING TYP
OFFSET DIMENSION AND PLACE REMAINING ITEMS ADJACENT TO FIRST
APPROX. LOCATED WITHIN 4 FEET OF OPEN DOOR
FOR PURPOSES OF THESE RULES, ITEMS SHOWN
ARE CONSIDERED TO BE ADJACENT TO DOOR.
AGAINST WALL OR RESTRICTION.
BY THIS DIAGRAM. DO NOT CROWD MULTIPLE ITEMS
ADJ TO FIRST ON SIDE OPP FRAME AS ILLUSTRATED
TO FRAME USING TYP OFFSET DIM AND PLACE REMAINING
HGT ARE INDICATED, MOUNT FIRST ITEM IN RELATION
WHEN MULTIPLE ITEMS HAVING THE SAME TYP MTG
DOOR, AND WHEN STRIKE-SIDE CLEARANCE IS BETWEEN 12 INCHES AND
APPLIES: MOUNT ITEMS IN RELATION TO FRAME USING TYP OFFSET
DIMENSION. VERTICALLY ALIGN CENTERS OF ITEMS MOUNTED AT
WHEN NOT DIMENSIONED AND SHOWN LOCATED ADJ TO STRIKE SIDE OF
LINE OF WALL OR OTHER
RESTRICTION ON STRIKE-SIDE
OF DOOR.
18 INCHES, AND WHEN NO OTHER TYPICAL CONFIGURATION DIAGRAM
STRIKE-SIDE OF DOOR.
DIFFERENT HEIGHTS. WHEN MULTIPLE ITEMS HAVING THE SAME TYP MOUNTING HEIGHT ARE
INDICATED, MOUNT FIRST ITEM IN RELATION TO FRAME USING TYP
OFFSET DIMENSION AND PLACE REMAINING ITEMS ADJACENT TO FIRST
DIMENSION. VERTICALLY ALIGN CENTERS OF ITEMS MOUNTED AT
APPLIES: MOUNT ITEMS IN RELATION TO FRAME USING TYP OFFSET
BE ADJACENT TO DOOR (OR WINDOW).
LOCATED WITHIN 4 FEET OF DOOR ARE CONSIDERED TO
FOR PURPOSES OF THESE RULES, ITEMS SHOWN APPROX
SIMILAR RULE APPLIES WHEN ADJACENT TO WINDOW.
WHEN PROVIDED, UTILIZE
TYP MOUNTING
DIAGRAMS TO
DETERMINE DIMENSIONS
ON SIDE OPPOSITE FRAME AS ILLUSTRATED BY THIS DIAGRAM.
MULTIPLE ITEMS AT SAME HEIGHT
WHEN NOT DIMENSIONED AND SHOWN LOCATED ADJACENT TO
DOOR, AND WHEN NO OTHER TYPICAL CONFIGURATION DIAGRAM
DIFFERENT HEIGHTS.
MULTIPLE ITEMS AT SAME HEIGHT
DOOR WHEN SWUNG AGAINST WALL
DIFFERENT HEIGHTS.
WHEN MULTIPLE ITEMS HAVING THE SAME TYP MOUNTING HEIGHT ARE
WHEN NOT DIMENSIONED AND SHOWN LOCATED ON A COLUMN OR
HORIZONTALLY CENTER ITEM ON FACE OF COLUMN OR PILASTER.
ALIGN VERTICALLY CENTERS OF MULTIPLE ITEMS HAVING DIFFERING
INDICATED, HORIZONTALLY CENTER GROUP OF ITEMS ON FACE OF COLUMN
PILASTER, AND WHEN NO OTHER TYPICAL CONFIGURATION DIAGRAM APPLIES:
OR PILASTER (SEE RULE 3).
ON PLANS, ITEMS TO BE
VERTICALLY ALIGNED MAY
BE SHOWN ADJACENT.
TYPICAL MOUNTING HEIGHTS.
ARRANGE ITEMS AT SAME
HEIGHT SYMMETRICALLY
ABOUT CENTERLINE
DIFFERING AND SIMILAR MOUNTING HEIGHTS.
COLUMN OR PILASTER.
LOCATED WITHIN 4 FEET OF PLANE CHANGE ARE CONSIDERED
TO BE ADJACENT TO CHANGE IN PLANE.
MULTIPLE SIMILAR ITEMS AT SAME HEIGHT
FOR PURPOSES OF THESE RULES, ITEMS SHOWN APPROX
APPLIES: MOUNT ITEMS IN RELATION TO PLANE CHANGE USING TYP
OFFSET DIMENSION AND PLACE REMAINING ITEMS ADJACENT TO FIRST
WHEN MULTIPLE SIMILAR ITEMS HAVING THE SAME TYP MTG HEIGHT ARE
INDICATED, MOUNT FIRST ITEM IN RELATION TO PLANE CHANGE USING TYP
OFFSET DIM. VERTICALLY ALIGN CENTERS OF ITEMS MOUNTED AT
WHEN NOT DIMENSIONED AND SHOWN LOCATED ADJ TO CHANGE IN
PLANE OF WALL, AND WHEN NO OTHER TYP CONFIGURATION DIAGRAM
ON SIDE OPPOSITE PLANE CHANGE AS ILLUSTRATED BY THIS DIAGRAM.
DIFFERENT HEIGHTS.
CONFLICTING MOUNTING HEIGHT(S) ABOUT THE CENTERLINE OF
HORIZONTALLY CENTER GROUP OF DISSIMILAR ITEMS HAVING
DIFFERING, SIMILAR, AND CONFLICTING MOUNTING HEIGHTS.
THE COLUMN OR PILASTER.
(PREVIOUS) TO SYMMETRICALLY ARRANGE GROUPS OF ITEMS HAVING
WHEN APPLICABLE, COMBINE THIS RULE WITH RULE 2 AND/OR RULE 3
WHEN NOT DIMENSIONED AND SHOWN LOCATED ON A COLUMN OR
PILASTER, AND WHEN NO OTHER TYPICAL CONFIGURATION DIAGRAM APPLIES:
GRID
ARRANGE ITEMS AT
CONFLICTING HEIGHTS
SYMMETRICALLY ABOUT
CENTERLINE
GRID
GRID
DIMENSION ON PLANS
EQ EQ EQ EQ
6".
EQ EQ
EQEQ
18" MIN. SWING SIDE
12" MIN. OPP. SWING SIDE
3" MIN.
8" TYP. 8" TYP.
4'-0".
4'-0". DOOR SWING
8" TYP.
8" TYP.
4'-0".
EQ EQ
EQEQEQEQ
EQEQ
TYPICAL HANDICAP ACCESSIBLE MOUNTING HEIGHTS ABOVE FINISH FLOOR
DIMENSION
NAME ELEMENT
ADULTS
MOUNTING HEIGHT
CODE
REQUIREMENT
ACTUAL
DESIGNED
DRINKING FOUNTAIN (STANDING) 602.4 38" - 43" 40" SPOUT HT.M1
MOUNTING HEIGHT
REFERENCE ABOVE F.F. ADDITIONAL COMMENTS
602.4 36" MAX 35-1/2" SPOUT HT.M2
GRAB BAR AT TOILET - 18" VERTICAL 604.5 39" - 41" 40" TO BOTTOM OF RAILM3
GRAB BARS AT TOILET - HORIZONTAL 604.9 & 609.4 33" - 36" 34" TO TOP SURFACE OF RAILM4
HANDRAILS 505.4 34" - 38" 36" TO TOP SURFACE OF RAILM5A & M5B
M5A = ADULT DIMENSION, M5B = CHILDREN
DIMENSION OF SECOND HANDRAIL TO F.F.
LAVATORY 606.3 34" MAX 34"
TO HIGHEST POINT OF LAVATORY RIM
OR COUNTERM6
ONLY PRE-K AND KINDERGARTEN (IF PARALLEL APPROCH
PROVIDED) CAN HAVE SPACE BELOW LAVATORY ENCLOSED
MIRROR 606.3 35" MAX 12"M7
MIRROR ABOVE LAVATORY 606.3 40" MAX 40"M8
TOILET PAPER DISPENSOR 604.7 & 604.10 15" MIN 16" TO BOTTOM OF DISPENSERM9
URINAL 605 17" MAX 17" TO RIM, 13-1/2" MIN PROJECTIONM10
URINAL FLUSH CONTROLS 605.4 & 309 44" MAX 42" TO TOP OF CONTROLM11
WATER CLOSET HEIGHT 604.4 17" - 19" 18" TO TOP OF SEATM12
WATER CLOSET FLUSH CONTROLS 604.6 36" MAX 24" LOCATED ON OPEN SIDEM13
DRINKING FOUNTAIN (WHEELCHAIR)
ANSI A117.1
GUIDELINE
REFERENCE
TO BOTTOM EDGE OF REFLECTING SURFACE
TO BOTTOM EDGE OF REFLECTING SURFACE
WATER CLOSET FROM WALL 604.2 16" - 18" 17" WALL TO CENTERLINE OF WATER CLOSETP1
FIRE EXTINGUISHER 308 48" MAX 48" TO RELEASE CLAMP
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT SCALE:
DRAWING NO. AMP-400-E-
LO
C
A L
FI
LE
P
LO
T D
A
TE
LW
P B
J O
B N
O
C E
N
TR
A L
FI
LE
A
B
C
D
E
F
G
A
B
C
D
E
F
G
TE
M
P
LA
T E
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S.
government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
ISSUED BY
OFFICE OF:
FACILITY MANAGEMENT
AMP-400
PROJECT MANAGER:
CYNTHIA HURD, AMP-400
WORK REQUEST NO:
CARSR / ASR 1/2 TRAINING CENTER
7/15/2014
As indicated
C :\U se rs
\b w in te rs ch ei d t\D oc um en ts \F
A A
C A
R S
R R
A D
A R
C E
N
TE
R A
R C
H
IT
E C
TU
R
A L_
B W in te rs ch ei d t.r vt
7/
/2
:1 6:
P
M
CARSR / BEACON 5 & 6 RELOCATION PROJECT
7900 W McLUCAS ST OKLAHOMA CITY, OKLAHOMA
MOUNTING HEIGHTS,
LOCATIONS AND
CONFIGURATIONS
G1.3ETS
BMW
2013-007862
-1
8-
G
2B
\\l w p b
-f ile sr vr
\F ed er al
FA
A \F
A A
ID
IQ
\T
O
Ty p e B s er vi ce
C A
R S
R \0
D w g s\
FA
A C
A R
S R
R A
D A
R C
E N
TE
R
A R
C H
IT
E
C
TU
R A
L.
rv t
LW
P
B
3.
0 4
U p d at ed to .0
JULY 15, 2014
CYNTHIA HURD, AMP-400
2013-007862
7"-9" M
M
" M
IN
M
IN
1/ 2"
3'-4"
TOILET
ACCESSORY
MOUNTING
LOCATION
M
M
M
M
STAIRS
(a)
RAMPS
(b)
WALKING
SURFACES
(c)
M 5A
M
5AM
5A
M 5B
M 5B
SECOND HANDRAIL
M 5B
M
IN
1'
3"
M
IN
5'
0"
1' - 0"3' - 6"
SE
E
N O
TE
3'
0"
PROVIDE BOTH
VERTICAL AND
HORIZONTAL
GRAB BARS
P1
3' - 4"
NOTE: FOR TOILETS WITH CENTERLINE LESS THAN 15", A
24" MIN. GRAB BAR TO OPEN SIDE MAY BE USED IN LIEU OF
FULL 36" MIN. LENGTH. REFER TO MOUNTING CHART BELOW.
OPEN
SIDE
CL
2'
0" 1'
0"
WALL-HUNG
M
M
1'-1 1/2"
M
M 6 M
M 6M
REFLECTING
SURFACE
SECTION ELEVATION
" M
IN
M
M
PLAN SECTION
FRONT APPROACHES
NOTE: X=12 IN. IF DOOR HAS
BOTH A CLOSER AND LATCH
PUSH SIDE
PULL SIDE
NOTE: Y=48 IN. MIN. IF DOOR HAS
CLOSER
LATCH SIDE APPROACHES
NOTE: X=54 IN. MIN. IF DOOR
HAS CLOSER
PUSH SIDE
PULL SIDE
IBC/ANSI/ADAAG - ACCESSIBLE ROUTE
(TYPICAL FOR ALL DOORS)
" M
IN
" M
IN
. 18"
MIN.
X
24"
MIN.
X
" M
IN
Y
" M
IN
24"
MIN.
X=42 IN. MIN. IF Y=54 IN.
NOTE: Z=48 IN. MIN. IF DOOR HAS
BOTH A CLOSER AND LATCH.
NOTE: X=36 IN. MIN. IF Y=60 IN.
HINGE SIDE APPROACHES
PUSH SIDE
PULL SIDE
X Y
Z
" M
IN
54" MIN.
T-SHAPED WHEELCHAIR
TURNING AREA
ACCESSIBLE ELEMENT
60" DIA. WHEELCHAIR
TURNING AREA
ACCESSIBLE PARKING
SPACE FOR CARS OR VANS
ACCESSIBLE ENTRANCE
ACCESSIBLE ROUTE TO
ACCESSIBLE ENTRANCES
OR FACILITIES
LEGEND
AREA OF REFUGE
HC
AR
WHEELCHAIR ACCESSIBLE
SEATING LOCATION OR
ELEMENT ACCESS
HANDICAP ACCESSIBILITY ANALYSIS
I. APPLICABLE CODES AND CRITERIA
IN ORDER TO PROVIDE THE BEST
ACCESSIBILITY, THE MOST
STRINGENT REQUIREMENTS OF THE
GUIDELINES BELOW HAVE BEEN
EMPLOYED IN THIS DESIGN.
INTERNATIONAL BUILDING CODE
2009 (IBC) INTERNATIONAL CODE
COUNCIL / AMERICAN NATIONAL
STANDARDS INSTITUTE ICC / ANSI
A117.1 - 2003
AMERICANS WITH DISABILITIES ACT
2010 ADA STANDARDS FOR
ACCESSIBLE DESIGN
A.
B.
II. PROJECT SCOPE
A. NEW CONSTRUCTION / REMODEL
III. PRIMARY USER GROUPS
A. ADULTS
IV. ASSEMBLY SEATING ANALYSIS -
NOT APPLICABLE
IBC/ANSI/ADAAG SECTION 308 - ADULT REACH RANGES
OBSTRUCTED FORWARD REACHUNOBSTRUCTED FORWARD REACH OBSTRUCTED FORWARD REACH
M
IN
" M
AX
20"
MAX.
" M
AX
" M
AX
25"
MAX.
" M
AX
" M
AX
OBSTRUCTED SIDE REACHUNOBSTRUCTED SIDE REACH OBSTRUCTED SIDE REACH
M
IN
" M
AX
10"
MAX.
" M
AX
" M
AX
24"
MAX.
" M
AX
" M
AX
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT SCALE:
DRAWING NO. AMP-400-E-
LO
C
A L
FI
LE
P
LO
T D
A
TE
LW
P B
J O
B N
O
C E
N
TR
A L
FI
LE
A
B
C
D
E
F
G
A
B
C
D
E
F
G
TE
M
P
LA
T E
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S.
government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
ISSUED BY
OFFICE OF:
FACILITY MANAGEMENT
AMP-400
PROJECT MANAGER:
CYNTHIA HURD, AMP-400
WORK REQUEST NO:
CARSR / ASR 1/2 TRAINING CENTER
7/15/2014
As indicated
C :\U se rs
\b w in te rs ch ei d t\D oc um en ts \F
A A
C A
R S
R R
A D
A R
C E
N
TE
R A
R C
H
IT
E C
TU
R
A L_
B W in te rs ch ei d t.r vt
7/
/2
:1 6:
P
M
CARSR / BEACON 5 & 6 RELOCATION PROJECT
7900 W McLUCAS ST OKLAHOMA CITY, OKLAHOMA
ACCESSIBILITY REQUIREMENTS
G1.4ETS
BMW
2013-007862
-1
8-
G
2B
\\l w p b
-f ile sr vr
\F ed er al
FA
A \F
A A
ID
IQ
\T
O
Ty p e B s er vi ce
C A
R S
R \0
D w g s\
FA
A C
A R
S R
R A
D A
R C
E N
TE
R
A R
C H
IT
E
C
TU
R A
L.
rv t
LW
P
B
3.
0 4
U p d at ed to .0
JULY 15, 2014
CYNTHIA HURD, AMP-400
2013-007862
VERTICAL BAR ELEVATION (TYP.) ACCESSIBILE HANDRAILS
ACCESSIBLE TOILET PLAN (TYP.)
ACCESSIBILE URINALS ACCESSIBILE LAVATORIES & MIRRORS
ACCESSIBILE DRINKING FOUNTAINS
GENERAL NOTES:
1. PORTABLE FIRE EXTINGUISHERS NOT
EXCEEDING 40 LBS SHALL BE MOUNTED
WITH HANDLE 4'-0" A.F.F. EXTINGUISHERS
MORE THAN 40 LBS SHALL BE MOUNTED
WITH HANDLE 3'-4" A.F.F.
FEC
FEB
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER BRACKET
2 HOUR FIRE RATED PARTITION
1 HOUR FIRE RATED PARTITION
NON-FIRE RATED PARTITION THAT
RESISTS THE PASSAGE OF SMOKE
FIRE PROTECTION LEGEND
PATH OF EGRESS TRAVEL
COMMON PATH OF TRAVEL
DEAD END
115'-6"
82'-0"
HC
HC
HC
HC
HC
HC
HC
HC
HC
MaxActual
Min
W idt h Ca pa cit y
Actual
68.5" 32.0"
MaxActual
Min
W idt h Ca pa cit y
Actual
33.8" 32.0"
MaxActual
Min
W idt h Ca pa cit y
Actual
68.5" 32.0"
MaxActual
Min
W idt h Ca pa cit y
Actual
33.8" 32.0"
MaxActual
Min
W idt h Ca pa cit y
Actual
33.8" 32.0"
MaxActual
Min
W idt h Ca pa cit y
Actual
33.8" 32.0"
FEC
FECFEC
FEB
FEC
FEC
FEC
39'-8"
59'-11"
BUILDING CODE CRITERIA SUMMARY
Applicable Codes and Criteria:
2009 ICC International Building Code (IBC), as amended by OKC 2008 ICC 500, ICC/NSSA Standard on the Design and Construction of Storm Shelters 2003 ICC/ANSI A117.1, Accessible and Usable Buildings and Facilities 2010 ADA Standards
I. Use AND Occupancy Classification (Chapter 3) A. Primary occupancy
1. B - Business (Section 304) B. Incidental use area separation requirements (Table 508.2.5 and Table 508.3)
1. Storage rooms over 100 SF in area:
Automatic fire extinguishing system with non fire rated walls that resist the passage of smoke.
II. General Building Heights and Areas (Chapter 5) A. Table 503 noncombustible Type II B
1. Allowable Height: 3 stories, 55 feet
2. Allowable Area: 23,000 SF per floor
B. Height Modifications (Section 504):
1. Automatic sprinkler increase (Section 504.2):
1 story, 20 feet
2. Total allowable height with increases:
3 stories, 75 feet
C. Actual building height as designed:
1 story, 23 feet
D. Area Modifications (Section 506):
1. Fire Area, Frontage Increase (Section 506.2):
100 (566/578 - .25) (30/30) = 72.9
2. Fire Area, Automatic sprinkler increase (Section 506.3):
300% for single story building
3. Fire Area, Total allowable area with increases:
= 68,570 SF
14,500 +
(14,500)(72.9) 100 +
(14,500)(300)
Fire Area : 16,665 SF E. Actual building area as designed:
III. Types of Construction (Chapter 6) A. Table 601 Type II B fire-resistance-rating:
1. For all building elements - 0 hours.
B. Table 602 Type II B, Group B fire-resistance-rating:
1. For exterior walls with more than 10' separation - 0 hours.
All exterior walls have more than 10' separation as designed.
IV. Fire-Resistance-Rated Construction (Chapter 7) A. ICC 500 requires storm shelters that are part of a larger building to be separated by a 2-Hour fire barrier.
B. Table 715.4 Fire Door and Shutter Assemblies.
2-Hour Fire Walls or Fire Barriers = 90 minutes
V. Fire Protection Systems (Chapter 9) This building is equipped throughout with an automatic sprinkler system
VI. Means of Egress (Chapter 10) A. Table 1004.1.1 Floor Area allowance per occupant:
1. Business areas: 100 gross sf/person for 8440 sf = 85
2. Accessory storage areas/mech. equipment room: 300 gross sf/person for 2434 sf = 9
Total occupant load = 94
B. Section 1007 Accessible means of egress.
1. All exit doors at grade are accessible
2. All exit stairs have a minimum of 48" width between handrails
C. Table 1016.1 Exit Access Travel Distance
1. 250' with sprinkler system Maximum travel distance as designed = 115' -6"
D. Table 1018.1 Corridor fire resistance rating:
1. 0-hours with sprinkler system.
E. Section 1005.1 Minimum Required Egress Width.
1. The total width of means of egress in inches shall not be less than the total occupant load served by means of egress multiplied by 0.3 per occupant for stairways and 0.2 per occupant for other egress components.
F. Section 1018.4 Dead Ends:
1. Maximum length - 20'.
No dead-end corridors as designed
G. Table 1021.1 minimum number of exits
1. 1 to 500 occupants - 2
1. 500 to 1,000 occupants - 3
1. More than 1,000 occupants - 4
Number of exits as designed = 10
VII. Miscellaneous Requirements:
A. Portable fire extinguishers are required in accordance with NFPA-101.
1. Maximum travel distance 75'-0"
Maximum travel distance as designed = 75' Number of FEC's/FEB's as designed = 27
Business
The minimum corridor width shall be as determined in section 1005.1, but not less than 44 inches.
All corridors are designed more than 44".
F. Section 1018.2 Corridor width.
42'-8"
FEB
T-SHAPED WHEELCHAIR
TURNING AREA
ACCESSIBLE ELEMENT
60" DIA. WHEELCHAIR
TURNING AREA
ACCESSIBLE PARKING
SPACE FOR CARS OR VANS
ACCESSIBLE ENTRANCE
ACCESSIBLE ROUTE TO
ACCESSIBLE ENTRANCES
OR FACILITIES
ACCESSIBILITY LEGEND
AREA OF REFUGE
HC
AR
WHEELCHAIR ACCESSIBLE
SEATING LOCATION OR
ELEMENT ACCESS
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT SCALE:
DRAWING NO. AMP-400-E-
LO
C
A L
FI
LE
P
LO
T D
A
TE
LW
P B
J O
B N
O
C E
N
TR
A L
FI
LE
A
B
C
D
E
F
G
A
B
C
D
E
F
G
TE
M
P
LA
T E
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S.
government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
ISSUED BY
OFFICE OF:
FACILITY MANAGEMENT
AMP-400
PROJECT MANAGER:
CYNTHIA HURD, AMP-400
WORK REQUEST NO:
CARSR / ASR 1/2 TRAINING CENTER
7/15/2014
As indicated
C :\U se rs
\b w in te rs ch ei d t\D oc um en ts \F
A A
C A
R S
R R
A D
A R
C E
N
TE
R A
R C
H
IT
E C
TU
R
A L_
B W in te rs ch ei d t.r vt
7/
/2
:1 6:
P
M
CARSR / BEACON 5 & 6 RELOCATION PROJECT
7900 W McLUCAS ST OKLAHOMA CITY, OKLAHOMA
BUILDING CODE CRITERIA
SUMMARY
G1.5ETS
BMW
2013-007862
-1
8-
G
2B
\\l w p b
-f ile sr vr
\F ed er al
FA
A \F
A A
ID
IQ
\T
O
Ty p e B s er vi ce
C A
R S
R \0
D w g s\
FA
A C
A R
S R
R A
D A
R C
E N
TE
R
A R
C H
IT
E
C
TU
R A
L.
rv t
LW
P
B
3.
0 4
U p d at ed to .0
JULY 15, 2014
CYNTHIA HURD, AMP-400
2013-007862
SCALE: 1" = 10'-0"A2.7 G1.5
TRAINING CENTER CODE SUMMARY &
ACCESSIBILITY PLAN
SCALE: 1" = 10'-0"A2.7 G1.5
STORAGE BUILDING CODE SUMMARY &
ACCESSIBILITY PLAN
N O
R
TH
TORNADO SHELTER
USABLE FLOOR AREA
EMERGENCY ESCAPE
TORNADO SHELTER ENTRY
MEN
WOMEN
G2.1 G2.1
SHELTER DESIGN INFORMATION
1. TYPE OF SHELTER: TORNADO
2. WIND DESIGN IN ACCORDANCE WITH ICC-500, 2008
3. DESIGN WIND SPEED: 250 MPH
4. IMPORTANCE FACTOR: 1.0
5. WIND EXPOSURE CATEGORY: C
6. INTERNAL PRESSURE COEFFICIENT: ±0.55
7. TOPOGRAPHIC FACTOR: 1.0
8. DIRECTIONALITY FACTOR: 1.0
9. THE TORNADO SHELTER IS LOCATED IN AN AREA DETERMINED TO BE
OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN (UNSHADED ZONE X).
REFER FEMA/NFIP FLOOD INSURANCE RATE MAP NUMBER 40109C0270H,
REVISED DECEMBER 18, 2009.
10. FLOOD ELEVATION: N/A
11. DOCUMENTATION THAT PRESSURE AND IMPACT REQUIREMENTS ARE MET:
REFER SPECIFICATIONS FOR REQUIRED SHOP DRAWINGS/SUBMITTALS
12. REFER ______ FOR LOCATION OF TORNADO SHELTER WITHIN BUILDING.
13. LOWEST SHELTER FLOOR ELEVATION: 1,304'
14. TORNADO SHELTER OCCUPANT LOAD: 40 @ WOMEN RM 6 / 45 @ MEN RM 7
15. USABLE SHELTER FLOOR AREA (ICC-500, 501.1.2.2):
205 SF @ WOMEN RM 6 / 230 SF @ MEN RM 7
16. VENTING AREA: ____ SQ IN; LOCATIONS: REFER M1.1
17. REFER ______ FOR SIGNAGE LOCATIONS AND REQUIREMENTS.
18. MINIMUM PLUMBING REQUIREMENTS:
1 TOILET, 0 HANDWASHING FACILITIES @ WOMEN RM 6 (40 OCCUPANTS)
1 TOILET, 0 HANDWASHING FACILITIES @ MEN RM 7 (45 OCCUPANTS)
19. REFER E3.1 FOR EMERGENCY LIGHTING REQUIREMENTS.
20. REFER DRAWINGS & SPECIFICATIONS FOR QUALITY ASSURANCE PLANS.
1/G2.1
1/A2.13
FEC FEC
WOMEN
MEN
6A 7A
6B 7B
020 016 013017
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT SCALE:
DRAWING NO. AMP-400-E-
LO
C
A L
FI
LE
P
LO
T D
A
TE
LW
P B
J O
B N
O
C E
N
TR
A L
FI
LE
A
B
C
D
E
F
G
A
B
C
D
E
F
G
TE
M
P
LA
T E
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S.
government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
ISSUED BY
OFFICE OF:
FACILITY MANAGEMENT
AMP-400
PROJECT MANAGER:
CYNTHIA HURD, AMP-400
WORK REQUEST NO:
CARSR / ASR 1/2 TRAINING CENTER
7/15/2014
As indicated
C :\U se rs
\b w in te rs ch ei d t\D oc um en ts \F
A A
C A
R S
R R
A D
A R
C E
N
TE
R A
R C
H
IT
E C
TU
R
A L_
B W in te rs ch ei d t.r vt
8/
/2
:5 8:
P
M
CARSR / BEACON 5 & 6 RELOCATION PROJECT
7900 W McLUCAS ST OKLAHOMA CITY, OKLAHOMA
TORNADO SHELTER PLAN
G2.1ETS
BMW
2013-007862
-1
8-
G
2B
\\l w p b
-f ile sr vr
\F ed er al
FA
A \F
A A
ID
IQ
\T
O
Ty p e B s er vi ce
C A
R S
R \0
D w g s\
FA
A C
A R
S R
R A
D A
R C
E N
TE
R
A R
C H
IT
E
C
TU
R A
L.
rv t
LW
P
B
3.
0 4
U p d at ed to .0
JULY 15, 2014
CYNTHIA HURD, AMP-400
2013-007862
SCALE: 1/16" = 1'-0"A1.2 G2.1
1 TORNADO SHELTER LOCATION PLAN
NORTH
SCALE: 1/8" = 1'-0"G2.1 G2.1
2 TORNADO SHELTER PLAN
ET
GM
TV
G
W
S
SS
TUG
OH
UGE
F
NOTED
NOTED
NOTED
NOTED
TBM
OR
ELEV.
C.O.
NOTED
C
UGE
P.C. CONC. (NOT PVM'T.)
P.C CONC. CURB & GUTTER
GAS LINE
FIRE LINE
BUILDING
STORM SEWER
WATER LINE
UNDERGROUND TELEPHONE
SANITARY SEWER
OVERHEAD ELECTRIC LINE
UNDERGROUND ELECTRIC
VALVE & VALVE BOX
ELECT. OR TELEPHONE POLE
FLAGPOLE
DOWN GUY WIRE
BENCH MARK
LIGHT POLE
FIRE HYDRANT
CONTOUR LINE
MANHOLE
SPOT ELEVATION
DIRECTION OF DRAINAGE
FENCE
ELECTRIC RISER
TELEPHONE RISER
TREES
WATER METER
CABLE TV RISER
SURVEY REF. POINT
CIVIL LEGEND
PROPOSED EXISTING
ELECTRIC TRANSFORMER
SWING GATE
INLET
CLEANOUT
POST INDICATOR VALVE
COMMUNICATION LINE
X X
GAS METER
E
T
W
SIGN
SS
S
F
W
G
1174.85
C.O.
FIRE DEPT. STAND PIPE CONNECTION
24"
C1.0
& CIVIL LEGEND
GENERAL NOTES
BITUMINOUS PAVEMENT
8" P.C. CONC. PVM'T.
10" P.C. CONC. PVM'T.
C
UGE
UNDERGROUND ELECTRIC PRIMARY UGP
ITEMS CONTAINED IN THESE PLANS ARE FOR BIDDING PURPOSES ONLY.
FROM THE CITY OF OKC FOR CONSTRUCTION OF THESE ITEMS. INFORMATION REGARDING THESE
CITY UTILITY AND ROADWAY PROJECTS. CONTRACTOR SHALL OBTAIN FINAL APPROVED PLANS
18. SANITARY SEWER MAIN, WATER LINE AND McLUCAS STREET EXTENSION ARE CITY OF OKLAHOMA
AND THE STRUCTURAL DRAWINGS.
SUBGRADE FOR BUILDINGS SHALL BE IN ACCORDANCE WITH THE GEOTECHNICAL REPORT
UNDER THE BUILDING SLAB TO A POINT 5' BEYOND THE PERIMETER OF THE BUILDING. IN ADDITION,
17. SUBGRADE FOR BUILDINGS: REMOVE EXISTING SUBGRADE SO AS TO PROVIDE A MINIMUM OF 4' OF SELECT FILL
COMPRESSIVE STRENGTH OF 4000 PSI.
DESIGN AND REINFORCEMENT SHALL CONFORM TO ASTM C-478, LATEST VERSION. MINIMUM
SHOWN FOR STORM, SANITARY, AND WATER LINE UTILITIES. PRECAST CONCRETE MANHOLE
16. PRECAST STRUCTURES MAY BE SUBSTITUTED FOR ALL CAST-IN-PLACE STRUCTURES
SHALL BE STOCKPILED IN AREAS DESIGNATED BY OWNER.
15. ALL AREAS TO BE GRADED SHALL BE STRIPPED OF TOPSOIL AND THE MATERIAL
PLANS FOR CONTINUATION.
14. CONSTRUCT UTILITY LINES TO WITHIN 5' OF THE BLDG. FOOTPRINT. SEE MECHANICAL
SIDEWALKS ARE DIMENSIONED TO BACK OF CURB.
13. ALL DIMENSIONS SHOWN ARE TO FACE OF CURB UNLESS OTHERWISE NOTED.
12. FOR UTILITY LOCATIONS CALL OKIE #1-800-522-OKIE.
REFER TO DETAILS.
11. ALL PROPOSED UNDERGROUND UTILITY LINES SHALL HAVE TRACE WIRE AND IDENTIFICATION TAPE, OR OTHER NON-GRAVITY, UNDERGROUND LINES.
PRECEDENCE OVER PRESSURIZED GAS LINES, WATER LINES, AND ELECTRIC, TELEPHONE,
CLEARANCE AT CROSSING POINTS. GRAVITY SANITARY AND STORM SEWER LINES HAVE
ASSURING THAT UTILITY LINES ARE CONSTRUCTED AT ELEVATIONS NECESSARY TO PROVIDE
10. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING, COORDINATING, AND
CAUSE ANY DAMAGE TO EXISTING UTILITIES.
9. THE CONTRACTOR WILL EXPOSE UTILITIES USING SUCH METHODS WHICH WILL NOT
OF OFF SITE.
MATERIAL OF ANY NATURE NOT USED NOR UTILIZED IN THIS CONSTRUCTION SHALL BE LEGALLY DISPOSED
8. CONTRACTOR SHALL PROVIDE A "CONSTRUCTION WASTE MANAGEMENT PLAN". ALL DEBRIS AND OTHER
THE OKLAHOMA DEPARTMENT OF ENVIRONMENTAL QUALITY. THIS INCLUDES NOI AND SWPPP.
THE OKLAHOMA CITY PUBLIC WORKS DEPARTMENT, STORMWATER MANAGEMENT DIVISION, AND
AND SILTATION. CONTRACTOR SHALL FILE A DUAL STORMWATER CONSTRUCTION PERMIT THROUGH
ENVIRONMENTAL LAWS AND REGULATIONS, INCLUDING NPDES, TO CONTROL EROSION
7. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE STORM WATER POLLUTION AND
AND PAYMENT.
EDITION 2009 AND ALL ERRATA THERETO. DISREGARD ALL REFERENCES TO MEASUREMENT
TRANSPORTATION'S STANDARD SPECIFICATIONS FOR HIGHWAY CONSTRUCTION,
SPECIFICATIONS SHALL BE IN ACCORDANCE WITH THE OKLAHOMA DEPARTMENT OF
6. CONSTRUCTION AND MATERIALS NOT INCLUDED IN THE PROJECT DRAWINGS AND
5. SEE MECHANICAL DRAWINGS FOR TELE./COMM. LINES AND DETAILS.
4. SEE ELECTRICAL DRAWINGS FOR ELECTRICAL LINES AND DETAILS.
THE GAS LINES AND ALL APPURTENANCES THERETO, AND ALL OTHER PROPERTY.
THEMSELVES, ALL OTHERS, PROPERTY OF THE OWNER, THE GENERAL CONTRACTOR,
ACCESS TO THE CONSTRUCTION SITE USE DILIGENT CARE AT ALL TIMES TO PROTECT
EMPLOYEES, SUBCONTRACTORS, SUBCONTRACTOR'S EMPLOYEES, AND ANYONE WITH
THE PROTECTION OF PROPERTY. FURTHER-MORE, THE CONTRACTOR SHALL ENSURE THAT
SHALL USE EXTREME CAUTION AND CARE WHILE EXCAVATING TO ENSURE SAFETY AND
EXISTING UNDERGROUND NATURAL GAS LINES AND OIL LINES. THE GENERAL CONTRACTOR
3. WARNING!!! PORTIONS OF THE WORK UNDER THIS CONTRACT EITHER CROSS OR PARALLEL
ALL OTHER PROPERTY.
CONTRACTOR, THE ELECTRICAL LINES AND ALL APPURTENANCES THERETO, AND
PROTECT THEMSELVES, ALL OTHERS, PROPERTY OF THE OWNER, THE GENERAL
ACCESS TO THE CONSTRUCTION SITE USE DILIGENT CARE AT ALL TIMES TO
EMPLOYEES, SUBCONTRACTORS, SUBCONTRACTOR'S EMPLOYEES AND ANYONE WITH
EXTREME CAUTION AND CARE RELATING TO SAFETY AND PROPERTY PROTECTION TO ENSURE
AND SERVICE LINES AND FIBER OPTIC LINES. THE GENERAL CONTRACTOR SHALL USE
PARALLEL EXISTING OVERHEAD AND/OR UNDERGROUND ELECTRICAL TRANSMISSION
2. WARNING!!! PORTIONS OF THE WORK UNDER THIS CONTRACT EITHER CROSS OR
PLANS.
UNDERGROUND AND OVERHEAD UTILITIES MAY EXIST THAT ARE NOT DEPICTED ON THESE
THESE DRAWINGS, BOTH HORIZONTAL AND VERTICAL, ARE ONLY APPROXIMATE. ADDITIONAL
AN ON-SITE SURVEY AND OTHER SOURCES. THE UTILITY LINE LOCATIONS SHOWN ON
1. WARNING!!! UTILITY LINES DEPICTED ON THESE DRAWINGS HAVE BEEN DEVELOPED FROM
GENERAL PROJECT NOTES
GRAVEL
SYMBOL DESCRIPTION DATE APPR
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT SCALE:
NDA
A
B
C
D
E
F
G
A
B
C
D
E
F
G
U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For
Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
OFFICE OF:
ISSUED BY
AMP-400
FACILITY MANAGEMENT
PROJECT MANAGER:
WORK REQUEST NO:
CARSR / ASR 1/2 TRAINING CENTER
C.O.A. No. 699 Renewal Date: 06-30-15
3033 N.W. 63rd Street, Suite 250E ~ Oklahoma City, OK 73116 ~ 405.848.2471
MacArthur Associated Consultants
DRAWING NO.
SSIONA
L
E N G
IN
E
ER
AMOHALKO
R
EG
IS
T E R E D
PR
OFE
SAM
G.
PAPPAS
16189
P R
IN
T D
A T
E
/2
/2
T
A \D ra w in g s \1
A -G
N .d g n
7900 W. McLucas St. OKLAHOMA CITY, OKLAHOMA
CARSR / BEACON 5 & 6 RELOCATION PROJECT
AMP-400-E-2013-007862
2013-007862
OKC (405) 840-5032
800-522-OKIE (6543)
SYSTEM, INC.
ONE-CALL
OKLAHOMA
TULSA (918) 732-OKIE (6543)
TO ANY EXCAVATION.
CONTACT THESE NUMBERS PRIOR
OF ALL UNDERGROUND UTILITIES.
FOR INFORMATION ON THE LOCATION
THESE NUMBERS ARE TO BE USED
KPF
JULY 15, 2014
AS SHOWN
CYNTHIA HURD, AMP-400CYNTHIA HURD, AMP-400
12'
40.67'
8'
E
T
SS
FH
12" RCP
C h a in L in k F e n c e
G
G
G
S S
OH OH OH OH OH OH OH
Storm Drain Inlet
Sanitary Sewer MH Rim=1299.29 FL South=1286.69
Street Lighting Box w/ 12"x12" Plastic Cover
Sign
LP
LP
WVWV
PP PP PP PP PP
LP
LP
Elec. MH
WM
W
WV
G G G G G G G G G G
McLUCAS ST.
S H
A F F
E R S
T
OILOILOILOILOILOILOILOILOIL
OH
O H
O H
O
IL
O
IL
O
IL
O
IL
O
IL W
O
IL
O
IL
O
IL
O
IL
W W
C C
U G
P U
G P
U G
P G
G
C C
OIL OIL
W WW W
UGP UGP
G
G OHOH
Comm. MH
O H
O H
O H
O K
C P
R O J E
C T S
D -1
8"
OKC PROJ. WA-0710
Elev.=1300.42 E=2077420.10 N=145853.27 W/ Cap Set 1#2" Iron Pin
CP #501
Elev.=1302.67 E=2077151.94 N=145300.15 W/ Cap
" Iron Pin2 1Set
CP #502
Elev.=1298.89 E=2078132.76 N=145532.93 W/ Cap Set 1#2" Iron Pin
CP #500
E #98
E #97
E #94
UGP
U G
P
U G
P
UGP UGP UGP
(REFER ELEC. PLANS)
(REFER ELEC. PLANS)
C C C C C
C C
C
(REFER MECH. PLANS) (REFER MECH. PLANS)
CC
M E
C H P
L A
N S
(R E
F E
R
SYMBOL DESCRIPTION DATE APPR
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT SCALE:
NDA
A
B
C
D
E
F
G
A
B
C
D
E
F
G
U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For
Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security
DEPARTMENT OF…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .