A003 (Attach 13(a))- E1 0 ELECTRICAL SITE PLAN.Attach 13(a
278 KB Posted
- Solicitation number
- DTFAAC-15-R-05677
About this file
A003 (Attach 13(a))- E1 0 ELECTRICAL SITE PLAN (pdf)
Text of this file
#9
#9
#9
#9
U G
P
UGP
UGP
UGP
UGP
U G
P U
G P
U G
P U
G P
U G
P U
G P
U G
P
UGE
(R E
FE
R
E
LE
C . P
LA
N
S) (R
E
FE
R E
LE
C
. P
LA
N S)
(R E
FE
R
E
LE
C . P
LA
N
S)
C C
C C
C C
C
CCC
(R E
FE
R
M E
C H
. P
LA
N S
(REFER MECH. PLANS)
(R E
FE
R
M E
C H
. P
LA
N S
S
S S
S
S
SSS
S S
12"
10"
8"
8"
12"15"
8"
8"
4"
S PROPOSED
BLDG.
FF=1304.00
PROPOSED
BLDG.
FF=1303.00
RADAR
TOWER
(BY OWNER)
STAIRS
(BY OWNER)
S S
SS
SS SS
S S
S S
S S
S S
S S
SSSS
4"
4"
8" 8"
8"
8" 8"
4"4"
F
W W
W W
W W
WWW
W 6"
1/
2"
8"
8" 8"
8" 8"
8"
6" W
W W
W
8" 8"
6"
W
F
8"
#9
#9
#9
UGP
UGP
U G
P U
G P
U G
P U
G P
U G
P U
G P
U G
P (R
E F
ER
E
LE
C . P
LA
N
S) (R
E F
ER
E
LE
C . P
LA
N
S) (R
E F
ER
E
LE
C . P
LA
N
S)
C C
C C
C C
(R
EF
ER
M
EC
H
. P
LA
N S)
(R
EF
ER
M
EC
H
. P
LA
N S)
SS
SS
SS
SS
SS
SS
SSSS
8" 8"
8"
8" 8"
4"
W W
W W
W W
W
8" 8"
8" 8"
8"
W 8"
ROCKWELL AVE.
QUESADA DR.
HALABY DR.
M cL
U C
AS
D
R
M cL
U C
AS
S
T.
SHAFFER ST.
SUBSTATION
#60
#1
46150
MH
46151
UGHV UGHV
UGHV
UGHV
U G
H V
U G
H V
U G
H V
U G
H V
U G
H V
U G
H V
U G
H V
U G
H V
U G
H V
U G
H V
U G
H V
U G
H V
O H
E O
H E
O H
E O
H E
OHE
OHE OHE OHE OHE OHE OHE OHE
OHEOHEOHEOHEOHE
OHE OHE
O H
E
O H
E O
H E
O H
E O
H E
O H
E O
H E
O H
E O
H E
O H
E O
H E
O H
E O
H E
O H
E O
H E
O H
E O
H E
O H
E O
H E
O H
E
OHEOHEOHE
UGHVUGHVUGHVUGHV
UGHV
U G
H V
U G
H V
U G
H V
U G
H V
O H
E O
H E
U C
U C
U C
U C
U C
U C
U C
U C
U C
U C
U C
U C
U C
U C
U C
U C
U C
U C
U C
U C
UC UC UC UC
E
E
#60 E
E
C
E
E C
C
#88
#E88A
#87
#86
UGHV
UGHV UGHV UGHV UGHV UGHVE
#85UGHVUGHV
UGHV
UC UC UC UC UC UC UC
UGHV UGHV
U G
H V
U G
H V
U G
H V
U G
H V
U G
H V
U G
H V
E #93
E
#94
U G
H V
U G
H V
U G
H V
U G
H V
U G
H V
E #97
PETROPETROPETROPETRO
PE
TR
O
PE
TR
O
PE
TR
O
PE
TR
O
PE
TR
O
PE
TR
O
PE
TR
O
PE
TR
O
PE
TR
O
PE
TR
O
PE
TR
O
PE
TR
O
PE
TR
O
PE
TR
O
PE
TR
O
PE
TR
O
PE
TR
O
U G
H V
U G
H V
U G
H V
U G
H V
U G
H V
U G
H V
E1.1
E1.1
E1.1
GAS GAS GAS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
W W
W
W
W
W
W
W
W
W W W W W W W W W W
SS SS
SS
W W
W W
W W
W
S16
E #98
S16
E1.2
S01
S02
S05
S06
S06
S10
S23
S15
S14
UGHV
UGHV
S29
S17
(2 EX, 2 EW)
(1 NEW, 1 EXISTING)
LIGHT LIGHT LIGHT LIGHT LIGHT
LI
G
H T
LI
G
H T
LI
G
H T
LI
G
H T
LI
G
H T
LI
G
H T
LIGHT
LIGHT LIGHT LIGHT
W W
W
SA2
SA2
SA2
SA2
S28
S28
S28
S28
E
S31
S31 S32
S33
S33
S33
S33
S37
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT SCALE:
DRAWING NO. AMP-400-E-
A
B
C
D
E
F
G
A
B
C
D
E
F
G
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
ISSUED BY
OFFICE OF:
FACILITY MANAGEMENT
AMP-400
PROJECT MANAGER:
CYNTHIA HURD, AMP-400
WORK REQUEST NO:
CARSR / ASR 1/2 TRAINING CENTER
P
AU
LS
G
R O
VE
E
N G
IN
EE
R
IN
G , P
.L .L
.C
C er tif ic at e of A ut ho riz at io n:
C A5
E xp ira tio n D at e:
J un e
, 2
As indicated
CARSR/BEACON 5 & 6 RELOCATION PROJECT
7900 W. McLucas St OKLAHOMA CITY, OKLAHOMA
ELECTRICAL SITE PLAN
E1.0CSP
CSP JULY 15, 2014
CYNTHIA HURD, AMP-400 1" = 200'-0"E1.0
1 ELECTRICAL SITE PLAN
1" = 50'-0"E1.0
2 ROADWAY LIGHTING PLAN
GENERAL NOTES
1. REF. SHEET E0.0 FOR LEGEND, ABBREVIATIONS AND GENERAL REQUIREMENTS
APPLICABLE TO WORK SHOWN ON THIS SHEET.
2. ALL ELECTRICAL SITE WORK SHALL BE PERFORMED IN ACCORDANCE WITH
FAA/MMAC STANDARDS, NFPA 70, NATIONAL ELECTRICAL SAFETY CODE, AND ALL
APPLICABLE STATE, FEDERAL AND LOCAL CODES.
3. NUMEROUS UNDERGROUND UTILITIES EXIST THROUGHOUT THIS SITE. COORDINATE
ALL WORK WITH CIVIL SURVEYS. LOCATE OR CAUSE TO BE LOCATED ALL UNDERGROUND
UTILITIES. DO NOT DISTURB EXISTING UTILITIES WITHOUT WRITTEN PERMISSION FROM
THE OWNER/ARCHITECT.
4. REF. SHEETS E1.3 THROUGH E1.7 FOR DETAILS PERTAINING TO SITE WORK.
5. ALL MEDIUM VOLTAGE WORK MUST BE PHASED TO ALLOW FOR A MAXIMUM TWO DAY
OUTAGE. PROVIDE A MINIMUM OF 21 DAYS ADVANCE NOTICE FOR ALL OUTAGES, COORDINATED
WITH FAA. ALL OUTAGE WORK MUST BE PERFORMED AFTER WORKING HOURS OR ON WEEKENDS.
KEYNOTE SCHEDULE
S01 REMOVE EXISTING SWITCHING CUBICLE #46150 AND RELOCATE TO THE
INTERSECTION OF McLUCAS AND SHAFFER, REF. KEYED NOTE S14.
S02 EXISTING SWITCHING CUBICLE # 46151, TO REMAIN. REVISE CIRCUITRY AS
SHOWN ON SINGLE-LINE DIAGRAM, SHEET E6.1.
S05 PROVIDE NEW SWITCHING CUBICLE, TYPE 11B SWITCHING ARRANGEMENT, IN
SAME LOCATION AS EXISTING RELOCATED SWITCH # 46150. RECONNECT
EXISTING CABLES TO 1,2 AND 4. PROVIDE NEW CABLES AS SHOWN ON
SINGLE-LINE DIAGRAM (SHEET E6.1) FROM NUMBER 3. PROVIDE NEW PAD PER
DETAIL 1, SHEET E1.3. LOCATION MUST BE CAREFULLY COORDINATED WITH
EXISTING UTILITIES.
S06 PROVIDE NEW CABLES IN EXISTING DUCTBANK, (1) SET 3#750, 15KV, ALUMINUM
WITH CONCENTRIC NEUTRAL AND OVERALL JACKET.
S10 PROVIDE NEW VFI STYLE SWITCHING CUBICLE ON NEW PAD. REF. DETAIL 1,
SHEET E1.3. CONNECT CIRCUITS AS SHOWN ON SINGLE-LINE DIAGRAM, SHEET
E6.1. LOCATION MUST BE CAREFULLY COORDINATED WITH EXISTING UTILITIES.
S14 RELOCATED SWITCHING CUBICLE #46150. CONNECT NEW CABLES AS SHOWN.
PROVIDE NEW PAD PER PLANS AND DETAILS. LOCATION MUST BE CAREFULLY
COORDINATED WITH EXISTING UTILITIES. REVISE AS REQUIRED.
S15 PROVIDE NEW CABLES IN NEW DUCTBANK, 3#4/0, 15KV ALUMINUM WITH
CONCENTRIC NEUTRAL AND OVERALL JACKET.
S16 PROVIDE NEW MANHOLE, REF. DETAILS 4 AND 5, SHEET E1.3. PROVIDE ONE
COMPLETE CABLE LOOP AROUND MANHOLE FOR EACH CABLE.
S17 PROVIDE NEW LOOP-FEED TYPE PAD MOUNT TRANSFORMER FOR SERVICE TO
NEW CARSR BUILDING. REF. LOW VOLTAGE SINGLE-LINE DIAGRAM, SHEET E6.2.
S23 PROVIDE NEW CABLES IN EXISTING DUCTBANK, (2) SETS-3#750, 15KV, ALUMINUM
WITH CONCENTRIC NEUTRAL AND OVERALL JACKET (REF. SINGLE-LINE DIAGRAM,
SHEET E6.1).
S28 EXTEND UNDERGROUND ROADWAY LIGHTING CIRCUIT TO NEW FIXTURES FROM
EXISTING STREET LIGHTING CIRCUIT WN4A-7 (30A/480V/1PH). CONNECT TO
CIRCUIT AT EXISTING LIGHT POLE LOCATED ON NE CORNER OF SHAFFER AND
MCLUCAS. STREET LIGHTING PANEL IS LOCATED AT THE NE INTERSECTION OF
HALLABY AND MCLUCAS.
S29 PROVIDE NEW CABLES IN NEW 1x2 DUCTBANK, (1) SET 3#4/0, 15KV ALUMINUM
WITH CONCENTRIC NEUTRAL AND OVERALL JACKET.
S31 EXISTING UNDERGROUND LIGHTING CIRCUIT.
S32 EXISTING ROADWAY LIGHTING POLE MOUNTED FIXTURE.
S33 NEW STREET LIGHTING CIRCUIT, 1"C-3#8,1#10GND.
S37 CONNECT NEW LIGHTING TO EXISTING CIRCUIT WN4A-7 (30A/480V/1PH) AT
EXISTING STREET LIGHTING POLE.
NOTE: CONTRACTOR SHALL FIELD-
VERIFY REQUIRED CONNECTION
POINT
TO EXISTING ROADWAY LIGHTING
CIRCUIT AND SHALL PROVIDE ALL
INTERCONNECTIONS AS NECESSARY.
COORDINATE WITH OWNER.
SYMBOL DESCRIPTION DATE APPR
1 Amendment #4 11-14-14
Other files
Show 40 more
Latest 50 of 165 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .