Drawings MGVC Roof Replacement.pdf
PDF 12 MB Posted
- Attached to
- Roof Replacement Mendenhall Glacier Visitor Center Federal contract opportunity
- Solicitation number
- 1240BJ
- Issued by
- Department of Agriculture Forest Service
About this file
This federal contract opportunity solicitation requests proposals for a roof replacement project at the Mendenhall Glacier Visitor Center. The solicitation seeks a contractor to demolish and remove the existing roof assembly down to the structural deck, install a temporary roofing system, and install a new PVC membrane roof assembly including substrate boards, vapor retarder, walkways, roof insulation, and accessories. Additional work includes building up a section of parapet on the observatory roof, installing new parapet cap flashing and spray foam insulation in parapets, and adding a roof drain with associated plumbing. An optional item is included for installing a roof ice melt system at all roof drains and overflows with associated electrical work. Contractors are to submit only the "Quoters Package" when providing pricing. The solicitation is issued by the Department of Agriculture Forest Service.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 1240BJ22R0002 Amendment 02 Attachment 01.pdf | ||
| 1240BJ22R0002 Amendment 02.pdf | ||
| 100 percent_MGVC SPECS 8-30-21.pdf | ||
| 1240BJ22R0002 Amendment 01.pdf | ||
| 1240BJ22R0002 Mendenhall Roof Solicitation.pdf | ||
| SOW Mendenhall Roof Replacement.pdf | ||
| WD AK20210001.pdf | ||
| Quoters Package.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
U.S. DEPARTMENT OF AGRICULTURE
FOREST SERVICE, REGION 10
JUNEAU RANGER DISTRICT
TONGASS NATIONAL FOREST
JUNEAU, ALASKA
AUGUST 30, 2021
CONSTRUCTION PLANS FOR:
MENDENHALL GLACIER VISITOR CENTER:
ROOF REPLACEMENT
INDEX TO SHEETS
NO. DESCRIPTION
A001 TITLE SHEET
A101 OVERALL SITE PLAN
A102 ENLARGED SITE PLAN
AD201 DEMOLITION ROOF PLAN
AD202 DEMOLTION PARTIAL PLAN & EXTERIOR
DETAILS
AD801 DEMOLITION EXTERIOR DETAILS
AD802 DEMOLITION EXTERIOR DETAILS
A201 ROOF PLAN
A202A ROOF DRAIN PIPING
A202B ROOF DRAIN PIPING
A202C ROOF DRAIN PIPING
A203 ICE MELT STYSTEM
A204 PARTIAL PLAN & EXTERIOR DETAILS
A301 EXISTING EXTERIOR ELEVATIONS
A302 EXISTING EXTERIOR ELEVATIONS
A801 EXTERIOR DETAILS
A802 EXTERIOR DETAILS
Jensen Yorba Wall Inc. A001
DWG SHEET NO.
JUNEAU
SITE PLAN (FOR REFERENCE ONLY)
DRAWING
TITLE
PROJECT NAME
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
(R-10)
REGION TEN
MENDENHALL
GLACIER VISITOR
CENTER ROOF
REPLACEMENT
TONGASS NATIONAL
FOREST
JUNEAU
RANGER DISTRICT
A101.dwg
WJ
BW
WJ
6960.021
OVERALL SITE PLAN
A101
NOT TO SCALE
PROVISIONAL LOCATION FOR CRANE
ACCESS TO ROOF- SEE A102
ACCESS FOR ALL TERRAIN TYPE
VEHICLES, 4' WIDE OR LESS;
TRAIL LENGTH APPROX .6 MILES
CONTRACTOR STAGING AREA
Jensen Yorba Wall Inc.
ENLARGED SITE PLAN (FOR REFERENCE ONLY)
DRAWING
TITLE
PROJECT NAME
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
(R-10)
REGION TEN
MENDENHALL
GLACIER VISITOR
CENTER ROOF
REPLACEMENT
TONGASS NATIONAL
FOREST
JUNEAU
RANGER DISTRICT
A102.dwg
WJ
BW
WJ
6960.021
ENLARGED SITE
PLAN
A102
NOT TO SCALE
NOTE:
PLANS, SECTIONS, OR ELEVATIONS ON THIS
SHEET ARE GRAPHIC REPRESENTATIONS OF
ORIGINAL CONSTRUCTION DOCUMENTS AND
ARE ASSUMED TO ACCURATELY REPRESENT
AS-BUILT CONDITIONS. SCALES ARE
APPROXIMATE, AND EXISTING CONDITIONS
SHOULD BE FIELD VERIFIED.
EXISTING
BUILDING
ATV ACCESS ROAD TO
CONTRACTOR STAGING AREA
DRIVEWAY TO CONTRACTOR
STAGING AREA
'-0
± 20'-0"
NOTE: ACCESS & CRANE STAGING SHOWN ON
THIS DRAWING ONLY AVAILABLE PRIOR TO MAY
1ST. & WHEN THE BUILDING IS CLOSED TO THE
PUBLIC
CRANE STAGING FOOT PRINT
APPROXIMATELY 20'x40'
± 12'-0" APPROXIMATE WIDTH
ACCESSWAY
Jensen
12 13
AD802
AD802
AD801
AD801
AD801
AD801
AD801
AD802
DEMOLITION ROOF PLAN
4'SCALE: 0 16'8'
DEMOLITION KEY NOTES:
REMOVE EXISTING ROOF ASSEMBLY
DOWN TO EXISTING VAPOR BARRIER -
SEE 4/AD801
REMOVE EXISTING PARAPET FLASHING
ASSEMBLY - SEE 1/AD801
REMOVE EXISTING ROOF EDGE
FLASHING - SEE 3/AD801
EXISTING CONCRETE CAP TO REMAIN -
SEE 2/AD801
ROOF DRAIN AND OVERFLOW DRAIN TO
REMAIN REMOVE EXISTING GRATE.
CLEAN EXISTING ROOF DRAIN BOWL
AND GRATE AND SALVAGE FOR
REINSTALLATION
ROOF MOUNTED RELIEF AIR VENT.
REMOVE AS REQUIRED TO REPLACE
ROOF AND SALVAGE FOR
REINSTALLATION - SEE 2/AD802
EXISTING CHIMNEY ENCLOSURE - SEE
AD202
CUT ROOF FOR ROOF DRAIN8
REMOVE EXISTING ANTENNAS.
PROTECT CABLES DURING
CONSTRUCTION
VENT THRU ROOF - PREPARE FOR ROOF
REPLACEMENT
BOILER FLUE CURB - SEE 1/AD80211
EXISTING PLYWOOD ROOF OVERLAY TO
BE REMOVED - SEE 5/AD801
FUEL OIL VENT PIPES - PREPARE FOR
ROOF REPLACEMENT
PROTECT EXISTING COMMUNICATIONS
CABLES DURING CONSTRUCTION
REMOVE CAP FLASHING @ EXISTING
PILASTERS (TOTAL 6)15
EXISTING SCUPPER TO REMAIN16
REMOVE EX LIGHT CONTROL PHOTOCELL
& SALVAGE FOR RE - INSTALLATION17
REMOVE AND SALVAGE FOR
REINSTALLATION EX ANEMOMETER, RAIN
GAUGE & WIRING.
DRAWING
TITLE
PROJECT NAME
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
(R-10)
REGION TEN
MENDENHALL
GLACIER VISITOR
CENTER ROOF
REPLACEMENT
TONGASS NATIONAL
FOREST
JUNEAU
RANGER DISTRICT
AD201.dwg
WJ
BW
WJ
6960.021
DEMOLITION ROOF
PLAN
AD201
AREA WHERE PWD OVERLAY OCCURS,
SEE NOTE 12
LEGEND:
Jensen
SCALE: 0 3" 6" 1'
3 CHIMNEY PHOTOGRAPH
21028 - AD202-3
REMOVE EXISTING
TRIM & SIDING &
REPLACE TO
MATCH EXISTING
REMOVE &
REPLACE
EXISTING METAL
FLASHING
EXISTING SIDING
& TRIM TO REMAIN
SEE 6/AD801
REMOVE METAL ROOF
AND ROOF EDGE
SCALE: 0 3" 6" 1'
4 CHIMNEY PHOTOGRAPH
21028 - A202-4
REMOVE EXISTING
CHIMNEY FLUE &
CAP
REMOVE
EXISTING TRIM &
SIDING &
REPLACE TO
MATCH EXISTING
PROTECT
EXISTING ELEC
CONDUIT & BOX
REMOVE
UNUSED PANEL
SCALE: 0 3" 6" 1'
5 CHIMNEY PHOTOGRAPH
21028-AD202-5
REMOVE EXISTING
CHIMNEY FLUE &
SALVAGE FOR
REINSTALLATION
REMOVE
EXISTING COMMUNICATION
DEVICES & SALVAGE FOR
REINSTALLATION - PROTECT
EXISTING WIRING
REMOVE EXISTING
STANDING SEAM
METAL ROOFING
REMOVE &
SALVAGE COVER
FOR
REINSTALLATION
REMOVE
EXISTING TRIM &
SIDING &
REPLACE TO
MATCH EXISTING
PROTECT EX
WIRING DURING
CONSTRUCTION
SCALE: 0 3" 6" 1'
2 CHIMNEY PHOTOGRAPH
21028 AD202-2
REMOVE EXISTING STANDING SEAM
METAL ROOFING AND PREPARE
FOR MEMBRANE APPLICATION
REMOVE
EXISTING
COMMUNICATION
DEVICES AND
SALVAGE FOR
REINSTALLATION
REMOVE EXISTING SIDING AND
TRIM & PREPARE FOR
REPLACEMENT SIDING AND TRIM
TO MATCH EXISTING
REMOVE EXISTING FLUE & CURB -
SALVAGE FOR REINSTALLATION
0 8' 12'SCALE: 2' 4'
1 PLAN VIEW CHIMNEY CAP
21028-AD202-1
REMOVE & SALVAGE EXISTING
SS CHIMNEY FLUE & SS CURB
REMOVE
EXISTING ANTENNAE
& SALVAGE FOR
REINSTALLATION
AD202 4
AD202
AD202
AD202
REMOVE EXISTING
CAMERA COVER
REMOVE EXISTING STANDING
SEAM METAL ROOFING @
CHIMNEY CAP
DRAWING
TITLE
PROJECT NAME
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
(R-10)
REGION TEN
MENDENHALL
GLACIER VISITOR
CENTER ROOF
REPLACEMENT
TONGASS NATIONAL
FOREST
JUNEAU
RANGER DISTRICT
AD202.dwg
WJ
BW
WJ
6960.021
DEMOLITION
PARTIAL PLAN &
EXTERIOR DETAILS
AD202
Jensen
3 ROOF EDGE DEMOLITION
21028/AD801-3
REMOVE
EXISTING
METAL
FLASHING
REMOVE EXISTING
TAPERED ROOF DOWN
TO EXISTING VAPOR
BARRIER - SEE 4/AD801,
SIM
EXISTING WOOD ROOF
STRUCTURE TO REMAIN
1x12
FASCIA
TRIM TO
REMAIN
2"
V E
R
IF
Y
'-0
6"
EXISTING WOOD FRAMED
SOFFIT & 1x12 SIDING
TO REMAIN
SEE 1/AD801
SCALE: 0 3" 6" 1'
1 TYP ROOF/PARAPET DEMO
12048/AD801-1
REMOVE EXISTING
METAL FLASHING
EXISTING RIGID INSUL &
TORCH DOWN ROOF &
MEMBRANE TO BE REMOVED
SEE 4/AD801
EXISTING STRUCTURE
TO REMAIN
EXISTING 3x6
STRUCTURE OR DECK AS
OCCURS
ASPHALT VAPOR
BARRIER TO REMAIN
EXISTING PWD SHTH
TO BE REMOVED
REMOVE EXISTING
MEMBRANE OVER PARAPET
EXISTING TRIM &
2-2x8 FRAMING TO
REMAIN
EXISTING 1x12
SIDING TO REMAIN
EXISTING
FASCIA
TRIM TO
REMAIN
SCALE: 0 3" 6" 1'
2 STONE PARAPET
12048/AD801-2
EXISTING 4"
CONCRETE
PARAPET CAP TO
REMAIN,
PRESSURE WASH
CONCRETE.
REMOVE EXISTING
ROOF ASSEMBLY -
SEE 4/AD801, SIM
STONE VENEER
TO REMAIN
CONCRETE WALL
TO REMAIN
'-0
EXISTING
MEMBRANE
EXISTING
MEMBRANE
SCALE: 0 3" 6" 1'
6 ROOF TO WALL
21028/AD801-6
REMOVE EXISTING
ROOF ASSEMBLY
AND METAL
FLASHING
SEE 1/AD801, SIM
1x12 SIDING
REMOVE AS
REQUIRED AND
SALVAGE FOR
REINSTALLATION
REMOVE EXISTING
ROOF ASSEMBLY
SEE 4/AD801
REMOVE EXISTING
ROOF PLYWOOD
SHEATHING
SCALE: 0 3" 6" 1'
4 TYPICAL ROOF DEMO
21028/AD801-4
REMOVE EXISTING
TORCH DOWN
ROOF MEMBRANE
& COVER BOARD
REMOVE EXISTING
± 6" RIGID
INSULATIONREMOVE EXISTING
TAPERED
INSULATION
EXISTING 3x T&G DECK
(WHERE OCCURS) TO
REMAIN
EXISTING STRUCTURAL
PLYWOOD DECK TO
REMAIN EXISTING TORCH
DOWN VAPOR
BARRIER TO
REMAIN
SCALE: 0 3" 6" 1'
5 OVERLAY DECK REMOVAL
21028/AD801-5
REMOVE EXISTING
TORCH DOWN
ROOF MEMBRANE
REMOVE EXISTING
2x FRAMING &
PLYWOOD
OVERLAY
EXISTING 3x T&G
ROOF & PLYWOOD
DECK TO REMAIN
DRAWING
TITLE
PROJECT NAME
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
(R-10)
REGION TEN
MENDENHALL
GLACIER VISITOR
CENTER ROOF
REPLACEMENT
TONGASS NATIONAL
FOREST
JUNEAU
RANGER DISTRICT
AD801.dwg
WJ
BW
WJ
6960.021
DEMOLITION
EXTERIOR DETAILS
AD801
Jensen
3 ROOF TO WALL
21028/AD802-3
EXISTING STONE
VENEER OVER
EXISTING
CONCRETE WALL
TO REMAIN
EXISTING ROOF
DECK TO REMAIN
6x6 STEEL LINTEL
TO REMAIN
REMOVE EXISTING
TERM BAR
REMOVE EXISTING
ROOF ASSEMBLY,
SEE 4/AD801
(V A
R
IE
S
SCALE: 0 3" 6" 1'
1 BOILER FLUE CURB DEMO
21028/AD802-1
EXISTING
STRUCTURAL ROOF
DECK TO REMAIN
EXISTING CURB
TO REMAIN
REMOVE EXISTING
CHIMNEY FLUE &
SALVAGE FOR
REINSTALLATION
REMOVE EXISTING
ROOF - SEE 5/AD801
REMOVE EXISTING
FLUE STORM COLLAR,
SALVAGE FOR
REINSTALLATION
SCALE: 0 3" 6" 1'
2 RELIEF AIR VENT CURB DEMO
21028/AD802-2
EXISTING
STRUCTURAL ROOF
DECK TO REMAIN
EXISTING CURB
TO REMAIN
REMOVE EXISTING
VENT FLASHING &
SALVAGE FOR
RE-INSTALLATION
REMOVE EXISTING
ROOF, SEE 4/AD801
(V A
R
IE
S
V E
R
IF
Y I
N F
IE
LD
DRAWING
TITLE
PROJECT NAME
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
(R-10)
REGION TEN
MENDENHALL
GLACIER VISITOR
CENTER ROOF
REPLACEMENT
TONGASS NATIONAL
FOREST
JUNEAU
RANGER DISTRICT
AD802.dwg
WJ
BW
WJ
6960.021
DEMOLITION
EXTERIOR DETAILS
AD802
Jensen
A802
A802
A802
A802
A802
A802
A802
A801
1 13
28'-5"
49'-5"
12'-1"
49'-0"
21'-0"
'-0
A802
EXISTING "UNAVCO"
CABLE DOWN FACE OF
BUILDING TO GRADE
REINSTALL EXISTING
"UNAVCO" CABLE TO
SIDE OF PARAPET W/
INSULATED STAINLESS
STEEL "C" CABLE
CLAMPS @ 4'-0" OC
REINSTALL EXISTING
PHOTOCELL
CABLE DOWN TO
EXISTING WALL PORTAL
ROOF PLAN
4'SCALE: 0 16'8'
ROOF PLAN KEY NOTES:
ROOF ASSEMBLY - SEE 1/A801
REPLACE EXISTING PARAPET - SEE
4/A801
REPLACE ROOF EDGE FLASHING - SEE
3/A801
COVER EXISTING CONCRETE PARAPET
W/ METAL FLASHING - SEE 2/A801
REINSTALL EXISTING ROOF DRAINS &
OVERFLOW DRAINS - SEE 1/A802
REINSTALL EXISTING RELIEF AIR VENTS
- SEE 5/A801
SEE SHEET A204 FOR RESIDING AND
REROOFING AT CHIMNEY
ROOF DRAIN - SEE 1/A802, SIM
SEE A202 FOR PIPING
POLYISO TAPERED CRICKET OVER
CONSTANT THICKNESS INSULATION AS
REQUIRED TO MAINTAIN ± 1/4" SLOPE TO
DRAINS
CAP EXISTING PILASTERS WITH METAL
FLASHING TO MATCH EXISTING
PROVIDE 2" DAM AT EXISTING SCUPPER
TO CREATE OVERFLOW SCUPPER
FLASH AROUND EXISTING ROOF VENTS
W/ PVC BOOT BY ROOF MEMBRANE
MANUFACTURER
FLASH AROUND EXISTING FUEL OIL
VENTS.
CURB @ EXISTING BOILER FLUE
- SEE 5/A801, SIM14
RADIO ANTENNA MOUNT - SEE 2/A802
REINSTALLATION OF ANTENNA AND
CABLE BY OWNER
REINSTALL ANEMOMETER & RAIN
GAUGE
REINSTALL EX WIRING FOR
ANEMOMETER AND RAIN GAUGE W/
INSULATED STAINLESS STEEL "C" CABLE
CLAMPS @ 4'-0" OC
JUNCTION BOX & CONTROLLER FOR ICE
MELT SYSTEM - SEE A203
18 ELECTROPLATED ZINC CABLE TRAY, 20'
LONG. MOUNT TO EXISTING WALL W/
STAINLESS STEEL FASTENERS.
PLATT MODEL # CF54200EZ W/ C50GC
MOUNTS @ 4'-0" OC
PLATT.COM (800) 257-5288
DRAWING
TITLE
PROJECT NAME
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
(R-10)
REGION TEN
MENDENHALL
GLACIER VISITOR
CENTER ROOF
REPLACEMENT
TONGASS NATIONAL
FOREST
JUNEAU
RANGER DISTRICT
A201.dwg
WJ
BW
WJ
6960.021
ROOF PLAN
A201
ARROW INDICATES ROOF SLOPE
LEGEND:
APPROX LOCATION OF COMMUNICATIONS
CABLE BY OWNER
Jensen Yorba Wall Inc.
1. PROVIDE 200 LF OF WALKWAYS,
LOCATE AS DIRECTED BY OWNER
GENERAL NOTES:
DRAWING
TITLE
PROJECT NAME
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
(R-10)
REGION TEN
MENDENHALL
GLACIER VISITOR
CENTER ROOF
REPLACEMENT
TONGASS NATIONAL
FOREST
JUNEAU
RANGER DISTRICT
A202A.dwg
WJ
BW
WJ
6960.021
ROOF DRAIN PIPING
A202A
ELEVATOR TUNNEL
NOT TO SCALE
ROOF DRAIN GENERAL NOTES:
1. CAST IRON ROOF DRAINAGE MATERIALS TO
BE PROVIDED & INSTALLED IN COMPLIANCE
WITH 2012 UNIFORM PLUMBING CODE
2. PROVIDE SECONDARY HANGARS & SEISMIC
BRACING TIED DIRECTLY INTO EXISTING
BUILDING STRUCTURE
3. SLOPE PIPING 1/4" PER FOOT MINIMUM.
PROVIDE CLEANOUTS AS REQUIRED BY
CODE
4. ROOF DRAIN TO BE ZURN 2121 NO HUB CAST
IRON ROOF DRAIN OR SIMILAR. INSTALL AS
DIRECTED BY MANUFACTURER
5. ROOF DRAIN PIPING TO CONFORM TO ASTM
A888 WITH STAINLESS STEEL COUPLERS
CONFORMING TO ASTM C1540, WITH
GASKETS CONFORMING TO ASTM C564. ALL
PIPE AND COUPLERS TO BE PROVIDED BY
SINGLE MANUFACTURER
6. ALL ROOF DRAIN WORK TO BE
ACCOMPLISHED BY PLUMBING
CONTRACTOR LICENCE IN THE STATE OF
ALASKA
7. INSULATE NEW PIPING W/ 1" FIBERGLASS &
VAPOR BARRIER - OWENS CORNING SSLII OR
EQUAL
ROOF DRAIN KEY NOTES:
3" CAST IRON ROOF DRAIN ABOVE
EXISTING CEILING
CONNECT 3" CAST IRON DRAIN PIPE TO
NEW ROOF DRAIN ABOVE - SEE A201
AND 1/A802
DROP 3" CAST IRON ROOF DRAIN DOWN
TO UTILITY SPACE ADJACENT TO
ELEVATOR TUNNEL, ROOM 002
METAL STUDS AND DRYWALL
CHASE AROUND VERTICAL 3" CAST IRON
DRAIN. ALIGN CHASE W/ EXISTING DOOR
FRAME TRIM. PROVIDE WOOD BASE TO
MATCH EXISTING. RUN CHASE FLOOR TO
CEILING ALONG EXISTING WALL - EXTEND
EXISTING ELECTRICAL OUTLET TO FACE OF
NEW WALL
CONNECT 3" CI DRAIN TO EXISTING 4"
CAST IRON STORM DRAIN
ELECTRICAL PANEL "F" SEE ICE MELT
SYSTEM SHEET A203
NOTE: EXISTING PLANS SHOWN FOR
REFERENCE, NEW WORK SHOWN CLOUDED
Jensen
LOWER FLOOR
DRAWING
TITLE
PROJECT NAME
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
(R-10)
REGION TEN
MENDENHALL
GLACIER VISITOR
CENTER ROOF
REPLACEMENT
TONGASS NATIONAL
FOREST
JUNEAU
RANGER DISTRICT
A202B.dwg
WJ
BW
WJ
6960.021
ROOF DRAIN PIPING
A202B
NOT TO SCALE
ROOF DRAIN GENERAL NOTES:
1. CAST IRON ROOF DRAINAGE MATERIALS TO
BE PROVIDED & INSTALLED IN COMPLIANCE
WITH 2012 UNIFORM PLUMBING CODE
2. PROVIDE SECONDARY HANGARS & SEISMIC
BRACING TIED DIRECTLY INTO EXISTING
BUILDING STRUCTURE
3. SLOPE PIPING 1/4" PER FOOT MINIMUM.
PROVIDE CLEANOUTS AS REQUIRED BY
CODE
4. ROOF DRAIN TO BE ZURN 2121 NO HUB CAST
IRON ROOF DRAIN OR SIMILAR. INSTALL AS
DIRECTED BY MANUFACTURER
5. ROOF DRAIN PIPING TO CONFORM TO ASTM
A888 WITH STAINLESS STEEL COUPLERS
CONFORMING TO ASTM C1540, WITH
GASKETS CONFORMING TO ASTM C564. ALL
PIPE AND COUPLERS TO BE PROVIDED BY
SINGLE MANUFACTURER
6. ALL ROOF DRAIN WORK TO BE
ACCOMPLISHED BY PLUMBING
CONTRACTOR LICENCE IN THE STATE OF
ALASKA
7. INSULATE NEW PIPING W/ 1" FIBERGLASS &
VAPOR BARRIER - OWENS CORNING SSLII OR
EQUAL
ROOF DRAIN KEY NOTES:
3" CAST IRON ROOF DRAIN ABOVE
EXISTING CEILING
CONNECT 3" CAST IRON DRAIN PIPE TO
NEW ROOF DRAIN ABOVE - SEE A201
AND 1/A802
DROP 3" CAST IRON ROOF DRAIN DOWN
TO UTILITY SPACE ADJACENT TO
ELEVATOR TUNNEL, ROOM 002
METAL STUDS AND DRYWALL
CHASE AROUND VERTICAL 3" CAST IRON
DRAIN. ALIGN CHASE W/ EXISTING DOOR
FRAME TRIM. PROVIDE WOOD BASE TO
MATCH EXISTING. RUN CHASE FLOOR TO
CEILING ALONG EXISTING WALL - EXTEND
EXISTING ELECTRICAL OUTLET TO FACE OF
NEW WALL
CONNECT 3" CI DRAIN TO EXISTING 4"
CAST IRON STORM DRAIN
ELECTRICAL PANEL "F" SEE ICE MELT
SYSTEM SHEET A203
NOTE: EXISTING PLANS SHOWN FOR
REFERENCE, NEW WORK SHOWN CLOUDED
Jensen
MAIN FLOOR
DRAWING
TITLE
PROJECT NAME
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
(R-10)
REGION TEN
MENDENHALL
GLACIER VISITOR
CENTER ROOF
REPLACEMENT
TONGASS NATIONAL
FOREST
JUNEAU
RANGER DISTRICT
A202C.dwg
WJ
BW
WJ
6960.021
ROOF DRAIN PIPING
A202C
NOT TO SCALE
ROOF DRAIN GENERAL NOTES:
1. CAST IRON ROOF DRAINAGE MATERIALS TO
BE PROVIDED & INSTALLED IN COMPLIANCE
WITH 2012 UNIFORM PLUMBING CODE
2. PROVIDE SECONDARY HANGARS & SEISMIC
BRACING TIED DIRECTLY INTO EXISTING
BUILDING STRUCTURE
3. SLOPE PIPING 1/4" PER FOOT MINIMUM.
PROVIDE CLEANOUTS AS REQUIRED BY
CODE
4. ROOF DRAIN TO BE ZURN 2121 NO HUB CAST
IRON ROOF DRAIN OR SIMILAR. INSTALL AS
DIRECTED BY MANUFACTURER
5. ROOF DRAIN PIPING TO CONFORM TO ASTM
A888 WITH STAINLESS STEEL COUPLERS
CONFORMING TO ASTM C1540, WITH
GASKETS CONFORMING TO ASTM C564. ALL
PIPE AND COUPLERS TO BE PROVIDED BY
SINGLE MANUFACTURER
6. ALL ROOF DRAIN WORK TO BE
ACCOMPLISHED BY PLUMBING
CONTRACTOR LICENCE IN THE STATE OF
ALASKA
7. INSULATE NEW PIPING W/ 1" FIBERGLASS &
VAPOR BARRIER - OWENS CORNING SSLII OR
EQUAL
ROOF DRAIN KEY NOTES:
3" CAST IRON ROOF DRAIN ABOVE
EXISTING CEILING
CONNECT 3" CAST IRON DRAIN PIPE TO
NEW ROOF DRAIN ABOVE - SEE A201
AND 1/A802
DROP 3" CAST IRON ROOF DRAIN DOWN
TO UTILITY SPACE ADJACENT TO
ELEVATOR TUNNEL, ROOM 002
METAL STUDS AND DRYWALL
CHASE AROUND VERTICAL 3" CAST IRON
DRAIN. ALIGN CHASE W/ EXISTING DOOR
FRAME TRIM. PROVIDE WOOD BASE TO
MATCH EXISTING. RUN CHASE FLOOR TO
CEILING ALONG EXISTING WALL - EXTEND
EXISTING ELECTRICAL OUTLET TO FACE OF
NEW WALL
CONNECT 3" CI DRAIN TO EXISTING 4"
CAST IRON STORM DRAIN
ELECTRICAL PANEL "F" SEE ICE MELT
SYSTEM SHEET A203
NOTE: EXISTING PLANS SHOWN FOR
REFERENCE, NEW WORK SHOWN CLOUDED
Jensen
6" 1'SCALE: 2'0
2 ROOF DRAIN ICE MELT SYSTEM
21028/A203-2
LOOP HEAT
TRACE CABLE ±
24" DOWN ROOF
DRAIN
TRACON MODEL FPT 130
HEAT TRACE CONTROLLER
ROOF OR WALL MOUNT
WEATHER PROOF J BOX &
DUPLEX OUTLET
J
3 WIRE/20A/120V POWER FROM
PANEL "F"/ 10 AWG IN 3/4" GMC
RUN HEAT TRACE CABLE TO OVERFLOW
DRAIN - LOOP CABLE (2) TIMES AROUND
OVERFLOW DRAIN DOME GRATE. H.T.S.
SELF REGULATING HEATING CABLE
LOOP HEAT TRACE ± 24"
DOWN OVERFLOW DRAIN
SELF REGULATING HEATING CABLE
(6W / FT @ 40° F) PLUG INTO DUPLEX
CONTINUOUS
HEAT TRACE
CABLE ON CABLE
JIG AND FRAME
CONNECT SENSOR TO
J-BOX W/ 1" LIQUID TIGHT
CABLE.
TEMPERATURE
SENSOR
OVERFLOW DRAIN, WHERE OCCURS
ICE MELT PLAN
4'SCALE: 0 16'8'
DRAWING
TITLE
PROJECT NAME
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
(R-10)
REGION TEN
MENDENHALL
GLACIER VISITOR
CENTER ROOF
REPLACEMENT
TONGASS NATIONAL
FOREST
JUNEAU
RANGER DISTRICT
A203.dwg
WJ
BW
WJ
6960.021
ICE MELT SYSTEM
A203
ICE MELT SYSTEM KEY NOTES:
WEATHER PROOF GFCI PROTECTED
JUNCTION BOX AND DUPLEX
RECEPTACLE MOUNTED ON 3/4"
GALVANIZED ELECTRICAL CONDUIT. 12"
ABOVE FINISHED ROOF - SEE 2/A203
WEATHER PROOF GFCI PROTECTED
JUNCTION BOX AND DUPLEX
RECEPTACLE MOUNTED TO WALL 16"
ABOVE FINISHED ROOF
VTR, EXTEND TO BE 12" ABOVE FINISHED ROOF
ROOF DRAIN/OVERFLOW DRAIN
SEE 2/A203 FOR ICE MELT
4 2
ICE MELT SYSTEM:
1. PROVIDE AN ICE MELT SYSTEM DESIGNED TO KEEP ROOF DRAINS AND ROOF OVERFLOWS FROM FREEZING. IT IS TO
AUTOMATICALLY OPERATE WHEN THE AIR TEMPERATURE REACHES BELOW 30 DEGREES AND TURN OFF WHEN
TEMPERATURES REACH 38 DEGREES AND ABOVE, BUT THAT IS FULLY ADJUSTABLE BY BUILDING OPERATORS.
2. SYSTEM TO BE DESIGNED AND SUPPLIED AS AN INTEGRATED SYSTEM BY VALIN CORPORATION INDUSTRIAL HEAT TRACING SOLUTIONS (801-205-3944) . PROVIDE COMPLETE SHOP DRAWINGS OF ALL COMPONENTS OF THE WORK WITH LAYOUT
DRAWINGS SHOWING LOCATIONS AND CONNECTIONS OF ALL COMPONENTS FOR A FULL AND COMPLETE OPERATIONAL SYSTEM. DEMONSTRATE OPERATION OF SYSTEM UPON COMPLETION, MAKING SYSTEM ADJUSTMENTS AS REQUIRED.
3. SYSTEM TO CONSIST OF:
a. ROOF OR WALL MOUNTED ELECTRICAL JUNCTION BOX WITH GFCI PROTECTED DUPLEX OUTLET: AT EACH PAIR OF
ROOF DRAINS AND OVERFLOW DRAINS, CONNECTED TO A SPARE 20 AMP, 120V BREAKER IN EXISTING ELECTRIC PANEL F WITH 3- 10 AGW CONDUCTORS PLUS GROUND IN ¾” EMT. PROVIDE ADDITIONAL JUNCTION BOX IN CEILING ABOVE
ELECTRIC PANEL, FISH MC CABLE DOWN TO WALL TO EXISTING PANEL F.
b. HEAT TRACE CONTROLLER: AT EACH ROOF OR WALL MOUNTED JUNCTION BOX TO ALLOW BUILDING OPERATORS TO SET DESIRED TEMPERATURE RANGE. CONTROLLER TO BE TRACON MODEL FPT 130 WITH NEMA 4XIP66 ENCLOSURE.
CONTROLLER TO INCLUDE OPENINGS FOR INPUT POWER, HEATER CABLE OUTPUT AND SEPARATE OUTPUT FOR
TEMPERATURE SENSOR.
c. HEAT TRACE CABLE: 120V MULTI SHIELDED HEATER CABLE, 6 WATT PER FOOT AT 40 DEGREES F. VALIN CORPORATION
HTS-6 SERIES SELF REGULATING HEATING CABLE. CONNECT TO HEAT TRACE CONTROLLER. RUN HEAT CABLE DOWN
ROOF DRAIN AND OVERFLOW DRAIN APPROXIMATELY 24 INCHES.
d. DE-ICING ARRAY AT EACH ROOF DRAIN CONSISTING OF 6 SLIP FIT DE-ICING JIGS AND FRAME FOR ANCHORING HEAT
CABLE WITHOUT PENETRATING ROOF MEMBRANE. KING MODEL 6RDDJ22.
GENERAL NOTES:
1. PROVIDE ICE MELT SYSTEM @ EACH ROOF
DRAIN AND OVERFLOW DRAIN PER 2/A203
2. CONNECT (2) EA SETS OF ROOF DRAINS TO
SINGLE 120V, 20A WIRE CIRCUIT, HOME RUN
TO ELECTRICAL PANEL "F" ROOM 207 (4)
HOME RUNS TOTAL, SEE GENERAL NOTE 6,
SHEET A202C
3. ICE MELT SYSTEM TO BE AS PROVIDED BY
HEAT TRACE SPECIALISTS, VALIN
CORPORATION, 801-205-3944
4. ALL POWER & CONTROL CONDUIT & WIRING
TO BE ACCOMPLISHED BY ELECTRICAL
CONTRACTOR LICENSED IN THE STATE OF
ALASKA
Jensen
5 CHIMNEY PHOTOGRAPH
21028-A204-5
REINSTALL
EXISTING SS
CHIMNEY FLUE &
CURB
80mil PVC ROOF
MEMBRANE W/
PVC CLAD METAL
ROOF EDGE -
SEE 6/A802 REINSTALL
EXISTING
CAMERA COVER
1x12 SHIP LAP & 1x TRIM TO
MATCH EXISTING
REINSTALL
EXISTING
CAMERA &
WIRING - BY
OWNER
REINSTALL
EXISTING
COMMUNICATIONS
ANTENNAE - BY
OWNER
SCALE: 0 3" 6" 1'
2 CHIMNEY PHOTOGRAPH
21028 A204-2
ADHERED 80mil PVC ROOF
MEMBRANE W/ PVC CLAD ROOF
EDGE
ANTENNAE
STAND BY OWNER
1x12 FASCIA & 1x12 SHIP LAP SIDING W/ 1x4 TRIM TO MATCH EXISTING -
SEE 5/A802
REINSTALL EXISTING FLUE & CURB
ANTENNAE DISH &
COMMUNICATIONS
RECIEVER BY
OWNER
SCALE: 0 3" 6" 1'
3 CHIMNEY PHOTOGRAPH
21028 - A204-3
1x4 TRIM TO
MATCH EXISTING
PVC CLAD
METAL FLASHING
EXISTING SIDING
& TRIM TO REMAIN
SEE 6/AD801
1x12 FASCIA TO
MATCH EXISTING
REPLACE
EXISTING SHIP
LAP SIDING W/
1x12 SHIP LAP
SIDING OVER
"GRACE ICE &
WATER SHIELD)
OVER 1/2" PWD
SHEATHING
SCALE: 0 3" 6" 1'
4 CHIMNEY PHOTOGRAPH
21028 - A204-4
REINSTALL EXISTING
CHIMNEY FLUE & CURB
1x12 FASCIA W/ 1x4 TRIM AND 1x12 SHIP LAP
SIDINGPVC CLAD ROOF EDGE
0 8' 12'SCALE: 2' 4'
1 PLAN VIEW CHIMNEY CAP
21028-A204-1
REINSTALL EXISTING SS
CHIMNEY FLUE & SS CURB
ANTENNAE REINSTALLATION BY OWNER
A204
A204
A204
A204
REINSTALL EXISTING
CAMERA COVER
OVERLAY EXISTING PLYWOOD
CHIMNEY SHEATHING W/
ADHERED 80mil PVC MEMBRANE
A802
NON-PENETRATION
ANTENNAE MOUNT &
ANTENNAE BY OWNER
DRAWING
TITLE
PROJECT NAME
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
(R-10)
REGION TEN
MENDENHALL
GLACIER VISITOR
CENTER ROOF
REPLACEMENT
TONGASS NATIONAL
FOREST
JUNEAU
RANGER DISTRICT
A204.dwg
WJ
BW
WJ
6960.021
PARTIAL PLAN &
EXTERIOR DETAILS
A204
Jensen
NORTH ELEVATION
DRAWING
TITLE
PROJECT NAME
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
(R-10)
REGION TEN
MENDENHALL
GLACIER VISITOR
CENTER ROOF
REPLACEMENT
TONGASS NATIONAL
FOREST
JUNEAU
RANGER DISTRICT
A301.dwg
WJ
BW
WJ
6960.021
EXISTING EXTERIOR
ELEVATIONS
A301
NOT TO SCALE
SOUTH ELEVATION
NOT TO SCALE
NOTE:
PLANS, SECTIONS, OR ELEVATIONS ON THIS
SHEET ARE GRAPHIC REPRESENTATIONS OF
ORIGINAL CONSTRUCTION DOCUMENTS AND
ARE ASSUMED TO ACCURATELY REPRESENT
AS-BUILT CONDITIONS. SCALES ARE
APPROXIMATE, AND EXISTING CONDITIONS
SHOULD BE FIELD VERIFIED.
EXISTING BUILDING ELEVATIONS (FOR REFERENCE ONLY)
'-0
APPROXIMATE ELEVATION
CRANE STAGING AREA
APPROXIMATE ELEVATION OF ATV
ROAD FORWARD OF ELEVATION
Jensen
EAST ELEVATION
DRAWING
TITLE
PROJECT NAME
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
(R-10)
REGION TEN
MENDENHALL
GLACIER VISITOR
CENTER ROOF
REPLACEMENT
TONGASS NATIONAL
FOREST
JUNEAU
RANGER DISTRICT
A302.dwg
WJ
BW
WJ
6960.021
EXISTING EXTERIOR
ELEVATIONS
A302
NOT TO SCALE
WEST ELEVATION
NOT TO SCALE
NOTE:
PLANS, SECTIONS, OR ELEVATIONS ON THIS
SHEET ARE GRAPHIC REPRESENTATIONS OF
ORIGINAL CONSTRUCTION DOCUMENTS AND
ARE ASSUMED TO ACCURATELY REPRESENT
AS-BUILT CONDITIONS. SCALES ARE
APPROXIMATE, AND EXISTING CONDITIONS
SHOULD BE FIELD VERIFIED.
EXISTING BUILDING ELEVATIONS (FOR REFERENCE ONLY)
APPROXIMATE GRADE
AT ATV ROAD
Jensen
3 PARAPET
21028 A801-3
WRAP PARAPET W/ PVC
MEMBRANE FLASHING
3"6"
#12x2" @ 18" OC
CONT CLIP
EXISTING TRIM
TO REMAIN
FILL EXISTING
PARAPET W/
SPRAY FOAM
INSULATION
PERIMETER FASTENERS
PER MEMBRANE MFR
MAX HEIGHT OF
TAPERED INSUL
EXISTING ROOF STRUCTURE
TO REMAIN
METAL PARAPET CAP W/ CONT CLIP
TO MATCH EXISTING RADIUS
EXISTING FASCIA
EXISTING ROOF
EDGE FRAMING &
SIDING
1'
-2
V E
R
IF
Y
#12 HEX HEAD FASTENER W/
EPDM WASHER @ 18" OC
CEDAR CONT
CANT STRIP
ROOF ASSEMBLY,
SEE 1/A801
SCALE: 0 3" 6" 1'
1 TYPICAL ROOF ASSEMBLY
21028/A801-1
1/2" DENS DECK
EXISTING STRUCTURAL
PLYWOOD
V A
R
IE
S
EXISTING VAPOR
BARRIER TO REMAIN
(ASSUMED TO BE
ADHERED ASPHALT)
EXISTING 3x6 WOOD
DECKING WHERE OCCURS
1/2" DENS DECK
MECHANICALLY FASTENED
PER MEMBRANE MFR.
(2) 2" POLYISO
80 MIL PVC
POLYISO TAPER
WHERE SHOWN
DO NOT PENETRATE THRU
WOOD DECK
NOTE: REPAIR OR REPLACE
VAPOR BARRIER WHERE
MISSING OR DAMAGED
DURING ROOF REMOVAL
SCALE: 0 3" 6" 1'
2 STONE PARAPET
12048/A801-2
TYP ROOF
ASSEMBLY - SEE
1/A801, SIM
STONE VENEER
TO REMAIN
CONCRETE
WALL TO
REMAIN
WRAP EXISTING
MEMBRANE
OVER PARAPET
1/2" TRTD PLYWOOD
PARAPET PVC
FLASHING
PERIMETER
FASTENER BY
MEMBRANE MFR, TYP
SEALANT
LAP EXISTING
MEMBRANE OVER
TERMINATION BAR &
SECURE W/ NON-
REACTIVE SEALANT
NON-REACTIVE SEALANT
EXISTING CAP TO
REMAIN
ALUMINUM
TERMINATION
BAR W/ 1/4"
DRIVE PINS AT
18" OC
SCALE: 0 3" 6" 1'
4 PARAPET
21028 A801-4
WRAP PARAPET W/ PVC
MEMBRANE FLASHING
3"
6"
CEDAR CONT
CANT STRIP
CONT CLIP
EXISTING TRIM
TO REMAIN
FILL EXISTING
PARAPET W/
SPRAY FOAM
INSULATION
PERIMETER
FASTENERS PER
MEMBRANE MFR
MAX HEIGHT OF
TAPERED INSUL
EXISTING ROOF
STRUCTURE TO
REMAIN
METAL PARAPET CAP W/
CONT CLIP TO MATCH
EXISTING RADIUS
EXISTING FASCIA
EXISTING ROOF
EDGE FRAMING &
SIDING
1'
-2
V E
R
IF
Y
#12 HEX HEAD
FASTENER W/ EPDM
WASHER @ 18" OC
#12x2"
@ 18" OC
ROOF
ASSEMBLY,
SEE 1/A801
SCALE: 0 3" 6" 1'
6 PARAPET
21028 A801-6
WRAP PARAPET W/ PVC
MEMBRANE FLASHING
3"
6"
CEDAR CONT
CANT STRIP
METAL
FLASHING
AND CONT
CLIP
EXISTING
TRIM
TO REMAIN
FILL PARAPET W/
SPRAY FOAM
INSULATION
PERIMETER
FASTENERS PER
MEMBRANE MFR
MAX HEIGHT OF
TAPERED INSUL
EXISTING ROOF
STRUCTURE TO
REMAIN
METAL PARAPET CAP W/
CONT CLIP
1'
-2
V E
R
IF
Y
EXISTING FASCIA
EXISTING ROOF
EDGE FRAMING &
SIDING
#12 HEX HEAD FASTENER
W/ EPDM WASHER
@ 18" OC
#12x2"
@ 18" OC
ROOF
ASSEMBLY, SEE
1/A801
SCALE: 0 3" 6" 1'
5 CURB (BOILER FLUE SIM)
21028/AD801-5
EXISTING
STRUCTURAL ROOF
DECK
EXISTING CURB
REINSTALL
EXISTING VENT
FLASHING
ROOF ASSEMBLY, SEE
1/A801
(V A
R
IE
S
V E
R
IF
Y I
N F
IE
LD
SPRAY FOAM
INSULATION
REPLACE EXISTING
PLYWOOD SHEATHING
#12 HEX HEAD
FASTENER W/ EPDM
WASHER @ 18" OC
RELIEF AIR VENT
DRAWING
TITLE
PROJECT NAME
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
(R-10)
REGION TEN
MENDENHALL
GLACIER VISITOR
CENTER ROOF
REPLACEMENT
TONGASS NATIONAL
FOREST
JUNEAU
RANGER DISTRICT
A801.dwg
WJ
BW
WJ
6960.021
EXTERIOR DETAILS
A801
Jensen
4 ROOF TO WALL
21028/A802-4
EXISTING STONE
VENEER OVER
EXISTING
CONCRETE WALL
EXISTING ROOF
DECK TO REMAIN
EXISTING 6x6
STEEL LINTEL
TO REMAIN
CONCRETE DRIVE
PIN @ 18" OC AND
TERMINATION BAR
ROOF ASSEMBLY,
SEE 1/A801
(V A
R
IE
S
SCALE: 0 3" 6" 1'
1 TYPICAL ROOF DRAIN (OVERFLOW SIM)
21028/A802-1
REINSTALL EXISTING
GRATE AND CLAMP RING
EXISTING ROOF
DECK & FRAMING
TYP, ROOF
ASSEMBLY, SEE
1/A801
EXISTING PIPING &
PIPE INSULATION
FOAMED IN PLACE
INSULATION AROUND
ROOF DRAIN
EXISTING ROOF DRAIN
BOWL - ADJUST HEIGHT
AS REQUIRED
HEAT CABLE & JIG
- SEE A203
SCALE: 0 3" 6" 1'
3 ROOF TO WALL
21028/A802-3
ROOF
ASSEMBLY
SEE 1/A801,
SIM
REINSTALL
EXISTING 1x12
SIDING
ROOF ASSEMBLY
SEE 1/A801
PARAPET CAP
SEE 4/A801
COUNTER FLASHING
W/ FASTENERS
@12" OC
LAP WEATHER
BARRIER OVER
COUNTER
FLASHING
SEALANT, TYP
#12x2" @ 16" OC
#12 HEX HEAD
FASTENER W/
EPDM WASHER
@ 18" OC
FILL EXISTING
PARAPET W/
SPRAY FOAM
INSULATION
EXISTING BATT
INSUL
SCALE: 0 3" 6" 1'
2 RADIO MAST MOUNT
21028-A802-2
36" TRTD 2x6 NAILER
W/ (2) 3/8"X6" LAGS @
EACH STUD (6) TOTAL
2" GALVANIZED
ANTENNAE MAST
BY OWNER
2 1/2" GALVANIZED
SCHEDULE 40, 3' LONG
PIPE BRACKET
GALVANIZED STEEL
"U" STRAP W/ (2)
3/8"x3" BOLTS
COUNTERSUNK
INTO NAILER,
NAILER CENTERED
OVER (3) STUDS
EXISTING 1x12
SIDING
EXISTING
WEATHER
BARRIER
EXISTING
PWD SHEATHING
EXISTING
WOOD STUDS
EXISTING STUD
@ ±16" OC
6" 1'SCALE: 2'0
5 SECTION @ CHIMNEY
21028-A802/5
ROOF ASSEMBLY
- SEE 1/A801
1x12 SHIPLAP
SIDING OVER
GRACE "ICE &
WATER SHIELD"
OVER 1/2" PWD
SHEATHING
A802
SIM
A802
A802
A802
SIM
REINSTALL SS CAP & FIRE
WRAP PVC MEMBRANE OVER
2x CURB
ROOF
ASSEMBLY
- SEE 1/A801
EXISTING
FRAMING AS
OCCURS
PVC ADHERED
OVER DENSDECK
3"SCALE: 0 6"
ROOF EDGE @ CHIMNEY6
21028/A_802-6
1/2" DENS DECK
PVC FLASHING -
WALL TO MEMBRANE
& PVC CLAD METAL
6"
1/2" PWD WRAP PVC
MEMBRANE OVER
ROOF EDGE
PVC CLAD
METAL EDGE
CONT CLIP
CONT WEATHER
BARRIER
3/4" SHIM
1x12 FASCIA
1x4 TRIM BEYOND
1/2" PWD SHEATHING
1x12 SHIPLAP
EXISTING
FRAMING
FASTENERS PER
MEMBRANE MFR
DRAWING
TITLE
PROJECT NAME
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
(R-10)
REGION TEN
MENDENHALL
GLACIER VISITOR
CENTER ROOF
REPLACEMENT
TONGASS NATIONAL
FOREST
JUNEAU
RANGER DISTRICT
A802.dwg
WJ
BW
WJ
6960.021
EXTERIOR DETAILS
A802
Jensen
| 2021-10-29T08:25:17-0800 | |
| HARVEY HERGETT |
| L: | |
| 2021-10-26T15:16:51-0800 | |
| LEONARD JOB |
| 2021-10-26T17:06:48-0800 | |
| TRISTAN FLUHARTY |
| 2021-10-27T11:43:13-0800 | |
| Jordan Hall |
| 2021-10-27T14:35:36-0800 | |
| M. Earl Stewart |
| 2021-10-29T13:14:04-0800 | |
| JAMES KING |