Drawings MGVC Roof Replacement.pdf

PDF 12 MB Posted

Attached to
Roof Replacement Mendenhall Glacier Visitor Center Federal contract opportunity
Solicitation number
1240BJ
Issued by
Department of Agriculture Forest Service

About this file

This federal contract opportunity solicitation requests proposals for a roof replacement project at the Mendenhall Glacier Visitor Center. The solicitation seeks a contractor to demolish and remove the existing roof assembly down to the structural deck, install a temporary roofing system, and install a new PVC membrane roof assembly including substrate boards, vapor retarder, walkways, roof insulation, and accessories. Additional work includes building up a section of parapet on the observatory roof, installing new parapet cap flashing and spray foam insulation in parapets, and adding a roof drain with associated plumbing. An optional item is included for installing a roof ice melt system at all roof drains and overflows with associated electrical work. Contractors are to submit only the "Quoters Package" when providing pricing. The solicitation is issued by the Department of Agriculture Forest Service.

View the file

Other files for this federal contract opportunity

Other files attached to Roof Replacement Mendenhall Glacier Visitor Center, newest first.
File Type Posted
1240BJ22R0002 Amendment 02 Attachment 01.pdf PDF
1240BJ22R0002 Amendment 02.pdf PDF
100 percent_MGVC SPECS 8-30-21.pdf PDF
1240BJ22R0002 Amendment 01.pdf PDF
1240BJ22R0002 Mendenhall Roof Solicitation.pdf PDF
SOW Mendenhall Roof Replacement.pdf PDF
WD AK20210001.pdf PDF
Quoters Package.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

U.S. DEPARTMENT OF AGRICULTURE

FOREST SERVICE, REGION 10

JUNEAU RANGER DISTRICT

TONGASS NATIONAL FOREST

JUNEAU, ALASKA

AUGUST 30, 2021

CONSTRUCTION PLANS FOR:

MENDENHALL GLACIER VISITOR CENTER:

ROOF REPLACEMENT

INDEX TO SHEETS

NO. DESCRIPTION

A001 TITLE SHEET

A101 OVERALL SITE PLAN

A102 ENLARGED SITE PLAN

AD201 DEMOLITION ROOF PLAN

AD202 DEMOLTION PARTIAL PLAN & EXTERIOR

DETAILS

AD801 DEMOLITION EXTERIOR DETAILS

AD802 DEMOLITION EXTERIOR DETAILS

A201 ROOF PLAN

A202A ROOF DRAIN PIPING

A202B ROOF DRAIN PIPING

A202C ROOF DRAIN PIPING

A203 ICE MELT STYSTEM

A204 PARTIAL PLAN & EXTERIOR DETAILS

A301 EXISTING EXTERIOR ELEVATIONS

A302 EXISTING EXTERIOR ELEVATIONS

A801 EXTERIOR DETAILS

A802 EXTERIOR DETAILS

Jensen Yorba Wall Inc. A001

DWG SHEET NO.

JUNEAU

SITE PLAN (FOR REFERENCE ONLY)

DRAWING

TITLE

PROJECT NAME

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

(R-10)

REGION TEN

MENDENHALL

GLACIER VISITOR

CENTER ROOF

REPLACEMENT

TONGASS NATIONAL

FOREST

JUNEAU

RANGER DISTRICT

A101.dwg

WJ

BW

WJ

6960.021

OVERALL SITE PLAN

A101

NOT TO SCALE

PROVISIONAL LOCATION FOR CRANE

ACCESS TO ROOF- SEE A102

ACCESS FOR ALL TERRAIN TYPE

VEHICLES, 4' WIDE OR LESS;

TRAIL LENGTH APPROX .6 MILES

CONTRACTOR STAGING AREA

Jensen Yorba Wall Inc.

ENLARGED SITE PLAN (FOR REFERENCE ONLY)

DRAWING

TITLE

PROJECT NAME

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

(R-10)

REGION TEN

MENDENHALL

GLACIER VISITOR

CENTER ROOF

REPLACEMENT

TONGASS NATIONAL

FOREST

JUNEAU

RANGER DISTRICT

A102.dwg

WJ

BW

WJ

6960.021

ENLARGED SITE

PLAN

A102

NOT TO SCALE

NOTE:

PLANS, SECTIONS, OR ELEVATIONS ON THIS

SHEET ARE GRAPHIC REPRESENTATIONS OF

ORIGINAL CONSTRUCTION DOCUMENTS AND

ARE ASSUMED TO ACCURATELY REPRESENT

AS-BUILT CONDITIONS. SCALES ARE

APPROXIMATE, AND EXISTING CONDITIONS

SHOULD BE FIELD VERIFIED.

EXISTING

BUILDING

ATV ACCESS ROAD TO

CONTRACTOR STAGING AREA

DRIVEWAY TO CONTRACTOR

STAGING AREA

'-0

± 20'-0"

NOTE: ACCESS & CRANE STAGING SHOWN ON

THIS DRAWING ONLY AVAILABLE PRIOR TO MAY

1ST. & WHEN THE BUILDING IS CLOSED TO THE

PUBLIC

CRANE STAGING FOOT PRINT

APPROXIMATELY 20'x40'

± 12'-0" APPROXIMATE WIDTH

ACCESSWAY

Jensen

12 13

AD802

AD802

AD801

AD801

AD801

AD801

AD801

AD802

DEMOLITION ROOF PLAN

4'SCALE: 0 16'8'

DEMOLITION KEY NOTES:

REMOVE EXISTING ROOF ASSEMBLY

DOWN TO EXISTING VAPOR BARRIER -

SEE 4/AD801

REMOVE EXISTING PARAPET FLASHING

ASSEMBLY - SEE 1/AD801

REMOVE EXISTING ROOF EDGE

FLASHING - SEE 3/AD801

EXISTING CONCRETE CAP TO REMAIN -

SEE 2/AD801

ROOF DRAIN AND OVERFLOW DRAIN TO

REMAIN REMOVE EXISTING GRATE.

CLEAN EXISTING ROOF DRAIN BOWL

AND GRATE AND SALVAGE FOR

REINSTALLATION

ROOF MOUNTED RELIEF AIR VENT.

REMOVE AS REQUIRED TO REPLACE

ROOF AND SALVAGE FOR

REINSTALLATION - SEE 2/AD802

EXISTING CHIMNEY ENCLOSURE - SEE

AD202

CUT ROOF FOR ROOF DRAIN8

REMOVE EXISTING ANTENNAS.

PROTECT CABLES DURING

CONSTRUCTION

VENT THRU ROOF - PREPARE FOR ROOF

REPLACEMENT

BOILER FLUE CURB - SEE 1/AD80211

EXISTING PLYWOOD ROOF OVERLAY TO

BE REMOVED - SEE 5/AD801

FUEL OIL VENT PIPES - PREPARE FOR

ROOF REPLACEMENT

PROTECT EXISTING COMMUNICATIONS

CABLES DURING CONSTRUCTION

REMOVE CAP FLASHING @ EXISTING

PILASTERS (TOTAL 6)15

EXISTING SCUPPER TO REMAIN16

REMOVE EX LIGHT CONTROL PHOTOCELL

& SALVAGE FOR RE - INSTALLATION17

REMOVE AND SALVAGE FOR

REINSTALLATION EX ANEMOMETER, RAIN

GAUGE & WIRING.

DRAWING

TITLE

PROJECT NAME

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

(R-10)

REGION TEN

MENDENHALL

GLACIER VISITOR

CENTER ROOF

REPLACEMENT

TONGASS NATIONAL

FOREST

JUNEAU

RANGER DISTRICT

AD201.dwg

WJ

BW

WJ

6960.021

DEMOLITION ROOF

PLAN

AD201

AREA WHERE PWD OVERLAY OCCURS,

SEE NOTE 12

LEGEND:

Jensen

SCALE: 0 3" 6" 1'

3 CHIMNEY PHOTOGRAPH

21028 - AD202-3

REMOVE EXISTING

TRIM & SIDING &

REPLACE TO

MATCH EXISTING

REMOVE &

REPLACE

EXISTING METAL

FLASHING

EXISTING SIDING

& TRIM TO REMAIN

SEE 6/AD801

REMOVE METAL ROOF

AND ROOF EDGE

SCALE: 0 3" 6" 1'

4 CHIMNEY PHOTOGRAPH

21028 - A202-4

REMOVE EXISTING

CHIMNEY FLUE &

CAP

REMOVE

EXISTING TRIM &

SIDING &

REPLACE TO

MATCH EXISTING

PROTECT

EXISTING ELEC

CONDUIT & BOX

REMOVE

UNUSED PANEL

SCALE: 0 3" 6" 1'

5 CHIMNEY PHOTOGRAPH

21028-AD202-5

REMOVE EXISTING

CHIMNEY FLUE &

SALVAGE FOR

REINSTALLATION

REMOVE

EXISTING COMMUNICATION

DEVICES & SALVAGE FOR

REINSTALLATION - PROTECT

EXISTING WIRING

REMOVE EXISTING

STANDING SEAM

METAL ROOFING

REMOVE &

SALVAGE COVER

FOR

REINSTALLATION

REMOVE

EXISTING TRIM &

SIDING &

REPLACE TO

MATCH EXISTING

PROTECT EX

WIRING DURING

CONSTRUCTION

SCALE: 0 3" 6" 1'

2 CHIMNEY PHOTOGRAPH

21028 AD202-2

REMOVE EXISTING STANDING SEAM

METAL ROOFING AND PREPARE

FOR MEMBRANE APPLICATION

REMOVE

EXISTING

COMMUNICATION

DEVICES AND

SALVAGE FOR

REINSTALLATION

REMOVE EXISTING SIDING AND

TRIM & PREPARE FOR

REPLACEMENT SIDING AND TRIM

TO MATCH EXISTING

REMOVE EXISTING FLUE & CURB -

SALVAGE FOR REINSTALLATION

0 8' 12'SCALE: 2' 4'

1 PLAN VIEW CHIMNEY CAP

21028-AD202-1

REMOVE & SALVAGE EXISTING

SS CHIMNEY FLUE & SS CURB

REMOVE

EXISTING ANTENNAE

& SALVAGE FOR

REINSTALLATION

AD202 4

AD202

AD202

AD202

REMOVE EXISTING

CAMERA COVER

REMOVE EXISTING STANDING

SEAM METAL ROOFING @

CHIMNEY CAP

DRAWING

TITLE

PROJECT NAME

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

(R-10)

REGION TEN

MENDENHALL

GLACIER VISITOR

CENTER ROOF

REPLACEMENT

TONGASS NATIONAL

FOREST

JUNEAU

RANGER DISTRICT

AD202.dwg

WJ

BW

WJ

6960.021

DEMOLITION

PARTIAL PLAN &

EXTERIOR DETAILS

AD202

Jensen

3 ROOF EDGE DEMOLITION

21028/AD801-3

REMOVE

EXISTING

METAL

FLASHING

REMOVE EXISTING

TAPERED ROOF DOWN

TO EXISTING VAPOR

BARRIER - SEE 4/AD801,

SIM

EXISTING WOOD ROOF

STRUCTURE TO REMAIN

1x12

FASCIA

TRIM TO

REMAIN

2"

V E

R

IF

Y

'-0

6"

EXISTING WOOD FRAMED

SOFFIT & 1x12 SIDING

TO REMAIN

SEE 1/AD801

SCALE: 0 3" 6" 1'

1 TYP ROOF/PARAPET DEMO

12048/AD801-1

REMOVE EXISTING

METAL FLASHING

EXISTING RIGID INSUL &

TORCH DOWN ROOF &

MEMBRANE TO BE REMOVED

SEE 4/AD801

EXISTING STRUCTURE

TO REMAIN

EXISTING 3x6

STRUCTURE OR DECK AS

OCCURS

ASPHALT VAPOR

BARRIER TO REMAIN

EXISTING PWD SHTH

TO BE REMOVED

REMOVE EXISTING

MEMBRANE OVER PARAPET

EXISTING TRIM &

2-2x8 FRAMING TO

REMAIN

EXISTING 1x12

SIDING TO REMAIN

EXISTING

FASCIA

TRIM TO

REMAIN

SCALE: 0 3" 6" 1'

2 STONE PARAPET

12048/AD801-2

EXISTING 4"

CONCRETE

PARAPET CAP TO

REMAIN,

PRESSURE WASH

CONCRETE.

REMOVE EXISTING

ROOF ASSEMBLY -

SEE 4/AD801, SIM

STONE VENEER

TO REMAIN

CONCRETE WALL

TO REMAIN

'-0

EXISTING

MEMBRANE

EXISTING

MEMBRANE

SCALE: 0 3" 6" 1'

6 ROOF TO WALL

21028/AD801-6

REMOVE EXISTING

ROOF ASSEMBLY

AND METAL

FLASHING

SEE 1/AD801, SIM

1x12 SIDING

REMOVE AS

REQUIRED AND

SALVAGE FOR

REINSTALLATION

REMOVE EXISTING

ROOF ASSEMBLY

SEE 4/AD801

REMOVE EXISTING

ROOF PLYWOOD

SHEATHING

SCALE: 0 3" 6" 1'

4 TYPICAL ROOF DEMO

21028/AD801-4

REMOVE EXISTING

TORCH DOWN

ROOF MEMBRANE

& COVER BOARD

REMOVE EXISTING

± 6" RIGID

INSULATIONREMOVE EXISTING

TAPERED

INSULATION

EXISTING 3x T&G DECK

(WHERE OCCURS) TO

REMAIN

EXISTING STRUCTURAL

PLYWOOD DECK TO

REMAIN EXISTING TORCH

DOWN VAPOR

BARRIER TO

REMAIN

SCALE: 0 3" 6" 1'

5 OVERLAY DECK REMOVAL

21028/AD801-5

REMOVE EXISTING

TORCH DOWN

ROOF MEMBRANE

REMOVE EXISTING

2x FRAMING &

PLYWOOD

OVERLAY

EXISTING 3x T&G

ROOF & PLYWOOD

DECK TO REMAIN

DRAWING

TITLE

PROJECT NAME

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

(R-10)

REGION TEN

MENDENHALL

GLACIER VISITOR

CENTER ROOF

REPLACEMENT

TONGASS NATIONAL

FOREST

JUNEAU

RANGER DISTRICT

AD801.dwg

WJ

BW

WJ

6960.021

DEMOLITION

EXTERIOR DETAILS

AD801

Jensen

3 ROOF TO WALL

21028/AD802-3

EXISTING STONE

VENEER OVER

EXISTING

CONCRETE WALL

TO REMAIN

EXISTING ROOF

DECK TO REMAIN

6x6 STEEL LINTEL

TO REMAIN

REMOVE EXISTING

TERM BAR

REMOVE EXISTING

ROOF ASSEMBLY,

SEE 4/AD801

(V A

R

IE

S

SCALE: 0 3" 6" 1'

1 BOILER FLUE CURB DEMO

21028/AD802-1

EXISTING

STRUCTURAL ROOF

DECK TO REMAIN

EXISTING CURB

TO REMAIN

REMOVE EXISTING

CHIMNEY FLUE &

SALVAGE FOR

REINSTALLATION

REMOVE EXISTING

ROOF - SEE 5/AD801

REMOVE EXISTING

FLUE STORM COLLAR,

SALVAGE FOR

REINSTALLATION

SCALE: 0 3" 6" 1'

2 RELIEF AIR VENT CURB DEMO

21028/AD802-2

EXISTING

STRUCTURAL ROOF

DECK TO REMAIN

EXISTING CURB

TO REMAIN

REMOVE EXISTING

VENT FLASHING &

SALVAGE FOR

RE-INSTALLATION

REMOVE EXISTING

ROOF, SEE 4/AD801

(V A

R

IE

S

V E

R

IF

Y I

N F

IE

LD

DRAWING

TITLE

PROJECT NAME

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

(R-10)

REGION TEN

MENDENHALL

GLACIER VISITOR

CENTER ROOF

REPLACEMENT

TONGASS NATIONAL

FOREST

JUNEAU

RANGER DISTRICT

AD802.dwg

WJ

BW

WJ

6960.021

DEMOLITION

EXTERIOR DETAILS

AD802

Jensen

A802

A802

A802

A802

A802

A802

A802

A801

1 13

28'-5"

49'-5"

12'-1"

49'-0"

21'-0"

'-0

A802

EXISTING "UNAVCO"

CABLE DOWN FACE OF

BUILDING TO GRADE

REINSTALL EXISTING

"UNAVCO" CABLE TO

SIDE OF PARAPET W/

INSULATED STAINLESS

STEEL "C" CABLE

CLAMPS @ 4'-0" OC

REINSTALL EXISTING

PHOTOCELL

CABLE DOWN TO

EXISTING WALL PORTAL

ROOF PLAN

4'SCALE: 0 16'8'

ROOF PLAN KEY NOTES:

ROOF ASSEMBLY - SEE 1/A801

REPLACE EXISTING PARAPET - SEE

4/A801

REPLACE ROOF EDGE FLASHING - SEE

3/A801

COVER EXISTING CONCRETE PARAPET

W/ METAL FLASHING - SEE 2/A801

REINSTALL EXISTING ROOF DRAINS &

OVERFLOW DRAINS - SEE 1/A802

REINSTALL EXISTING RELIEF AIR VENTS

- SEE 5/A801

SEE SHEET A204 FOR RESIDING AND

REROOFING AT CHIMNEY

ROOF DRAIN - SEE 1/A802, SIM

SEE A202 FOR PIPING

POLYISO TAPERED CRICKET OVER

CONSTANT THICKNESS INSULATION AS

REQUIRED TO MAINTAIN ± 1/4" SLOPE TO

DRAINS

CAP EXISTING PILASTERS WITH METAL

FLASHING TO MATCH EXISTING

PROVIDE 2" DAM AT EXISTING SCUPPER

TO CREATE OVERFLOW SCUPPER

FLASH AROUND EXISTING ROOF VENTS

W/ PVC BOOT BY ROOF MEMBRANE

MANUFACTURER

FLASH AROUND EXISTING FUEL OIL

VENTS.

CURB @ EXISTING BOILER FLUE

- SEE 5/A801, SIM14

RADIO ANTENNA MOUNT - SEE 2/A802

REINSTALLATION OF ANTENNA AND

CABLE BY OWNER

REINSTALL ANEMOMETER & RAIN

GAUGE

REINSTALL EX WIRING FOR

ANEMOMETER AND RAIN GAUGE W/

INSULATED STAINLESS STEEL "C" CABLE

CLAMPS @ 4'-0" OC

JUNCTION BOX & CONTROLLER FOR ICE

MELT SYSTEM - SEE A203

18 ELECTROPLATED ZINC CABLE TRAY, 20'

LONG. MOUNT TO EXISTING WALL W/

STAINLESS STEEL FASTENERS.

PLATT MODEL # CF54200EZ W/ C50GC

MOUNTS @ 4'-0" OC

PLATT.COM (800) 257-5288

DRAWING

TITLE

PROJECT NAME

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

(R-10)

REGION TEN

MENDENHALL

GLACIER VISITOR

CENTER ROOF

REPLACEMENT

TONGASS NATIONAL

FOREST

JUNEAU

RANGER DISTRICT

A201.dwg

WJ

BW

WJ

6960.021

ROOF PLAN

A201

ARROW INDICATES ROOF SLOPE

LEGEND:

APPROX LOCATION OF COMMUNICATIONS

CABLE BY OWNER

Jensen Yorba Wall Inc.

1. PROVIDE 200 LF OF WALKWAYS,

LOCATE AS DIRECTED BY OWNER

GENERAL NOTES:

DRAWING

TITLE

PROJECT NAME

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

(R-10)

REGION TEN

MENDENHALL

GLACIER VISITOR

CENTER ROOF

REPLACEMENT

TONGASS NATIONAL

FOREST

JUNEAU

RANGER DISTRICT

A202A.dwg

WJ

BW

WJ

6960.021

ROOF DRAIN PIPING

A202A

ELEVATOR TUNNEL

NOT TO SCALE

ROOF DRAIN GENERAL NOTES:

1. CAST IRON ROOF DRAINAGE MATERIALS TO

BE PROVIDED & INSTALLED IN COMPLIANCE

WITH 2012 UNIFORM PLUMBING CODE

2. PROVIDE SECONDARY HANGARS & SEISMIC

BRACING TIED DIRECTLY INTO EXISTING

BUILDING STRUCTURE

3. SLOPE PIPING 1/4" PER FOOT MINIMUM.

PROVIDE CLEANOUTS AS REQUIRED BY

CODE

4. ROOF DRAIN TO BE ZURN 2121 NO HUB CAST

IRON ROOF DRAIN OR SIMILAR. INSTALL AS

DIRECTED BY MANUFACTURER

5. ROOF DRAIN PIPING TO CONFORM TO ASTM

A888 WITH STAINLESS STEEL COUPLERS

CONFORMING TO ASTM C1540, WITH

GASKETS CONFORMING TO ASTM C564. ALL

PIPE AND COUPLERS TO BE PROVIDED BY

SINGLE MANUFACTURER

6. ALL ROOF DRAIN WORK TO BE

ACCOMPLISHED BY PLUMBING

CONTRACTOR LICENCE IN THE STATE OF

ALASKA

7. INSULATE NEW PIPING W/ 1" FIBERGLASS &

VAPOR BARRIER - OWENS CORNING SSLII OR

EQUAL

ROOF DRAIN KEY NOTES:

3" CAST IRON ROOF DRAIN ABOVE

EXISTING CEILING

CONNECT 3" CAST IRON DRAIN PIPE TO

NEW ROOF DRAIN ABOVE - SEE A201

AND 1/A802

DROP 3" CAST IRON ROOF DRAIN DOWN

TO UTILITY SPACE ADJACENT TO

ELEVATOR TUNNEL, ROOM 002

METAL STUDS AND DRYWALL

CHASE AROUND VERTICAL 3" CAST IRON

DRAIN. ALIGN CHASE W/ EXISTING DOOR

FRAME TRIM. PROVIDE WOOD BASE TO

MATCH EXISTING. RUN CHASE FLOOR TO

CEILING ALONG EXISTING WALL - EXTEND

EXISTING ELECTRICAL OUTLET TO FACE OF

NEW WALL

CONNECT 3" CI DRAIN TO EXISTING 4"

CAST IRON STORM DRAIN

ELECTRICAL PANEL "F" SEE ICE MELT

SYSTEM SHEET A203

NOTE: EXISTING PLANS SHOWN FOR

REFERENCE, NEW WORK SHOWN CLOUDED

Jensen

LOWER FLOOR

DRAWING

TITLE

PROJECT NAME

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

(R-10)

REGION TEN

MENDENHALL

GLACIER VISITOR

CENTER ROOF

REPLACEMENT

TONGASS NATIONAL

FOREST

JUNEAU

RANGER DISTRICT

A202B.dwg

WJ

BW

WJ

6960.021

ROOF DRAIN PIPING

A202B

NOT TO SCALE

ROOF DRAIN GENERAL NOTES:

1. CAST IRON ROOF DRAINAGE MATERIALS TO

BE PROVIDED & INSTALLED IN COMPLIANCE

WITH 2012 UNIFORM PLUMBING CODE

2. PROVIDE SECONDARY HANGARS & SEISMIC

BRACING TIED DIRECTLY INTO EXISTING

BUILDING STRUCTURE

3. SLOPE PIPING 1/4" PER FOOT MINIMUM.

PROVIDE CLEANOUTS AS REQUIRED BY

CODE

4. ROOF DRAIN TO BE ZURN 2121 NO HUB CAST

IRON ROOF DRAIN OR SIMILAR. INSTALL AS

DIRECTED BY MANUFACTURER

5. ROOF DRAIN PIPING TO CONFORM TO ASTM

A888 WITH STAINLESS STEEL COUPLERS

CONFORMING TO ASTM C1540, WITH

GASKETS CONFORMING TO ASTM C564. ALL

PIPE AND COUPLERS TO BE PROVIDED BY

SINGLE MANUFACTURER

6. ALL ROOF DRAIN WORK TO BE

ACCOMPLISHED BY PLUMBING

CONTRACTOR LICENCE IN THE STATE OF

ALASKA

7. INSULATE NEW PIPING W/ 1" FIBERGLASS &

VAPOR BARRIER - OWENS CORNING SSLII OR

EQUAL

ROOF DRAIN KEY NOTES:

3" CAST IRON ROOF DRAIN ABOVE

EXISTING CEILING

CONNECT 3" CAST IRON DRAIN PIPE TO

NEW ROOF DRAIN ABOVE - SEE A201

AND 1/A802

DROP 3" CAST IRON ROOF DRAIN DOWN

TO UTILITY SPACE ADJACENT TO

ELEVATOR TUNNEL, ROOM 002

METAL STUDS AND DRYWALL

CHASE AROUND VERTICAL 3" CAST IRON

DRAIN. ALIGN CHASE W/ EXISTING DOOR

FRAME TRIM. PROVIDE WOOD BASE TO

MATCH EXISTING. RUN CHASE FLOOR TO

CEILING ALONG EXISTING WALL - EXTEND

EXISTING ELECTRICAL OUTLET TO FACE OF

NEW WALL

CONNECT 3" CI DRAIN TO EXISTING 4"

CAST IRON STORM DRAIN

ELECTRICAL PANEL "F" SEE ICE MELT

SYSTEM SHEET A203

NOTE: EXISTING PLANS SHOWN FOR

REFERENCE, NEW WORK SHOWN CLOUDED

Jensen

MAIN FLOOR

DRAWING

TITLE

PROJECT NAME

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

(R-10)

REGION TEN

MENDENHALL

GLACIER VISITOR

CENTER ROOF

REPLACEMENT

TONGASS NATIONAL

FOREST

JUNEAU

RANGER DISTRICT

A202C.dwg

WJ

BW

WJ

6960.021

ROOF DRAIN PIPING

A202C

NOT TO SCALE

ROOF DRAIN GENERAL NOTES:

1. CAST IRON ROOF DRAINAGE MATERIALS TO

BE PROVIDED & INSTALLED IN COMPLIANCE

WITH 2012 UNIFORM PLUMBING CODE

2. PROVIDE SECONDARY HANGARS & SEISMIC

BRACING TIED DIRECTLY INTO EXISTING

BUILDING STRUCTURE

3. SLOPE PIPING 1/4" PER FOOT MINIMUM.

PROVIDE CLEANOUTS AS REQUIRED BY

CODE

4. ROOF DRAIN TO BE ZURN 2121 NO HUB CAST

IRON ROOF DRAIN OR SIMILAR. INSTALL AS

DIRECTED BY MANUFACTURER

5. ROOF DRAIN PIPING TO CONFORM TO ASTM

A888 WITH STAINLESS STEEL COUPLERS

CONFORMING TO ASTM C1540, WITH

GASKETS CONFORMING TO ASTM C564. ALL

PIPE AND COUPLERS TO BE PROVIDED BY

SINGLE MANUFACTURER

6. ALL ROOF DRAIN WORK TO BE

ACCOMPLISHED BY PLUMBING

CONTRACTOR LICENCE IN THE STATE OF

ALASKA

7. INSULATE NEW PIPING W/ 1" FIBERGLASS &

VAPOR BARRIER - OWENS CORNING SSLII OR

EQUAL

ROOF DRAIN KEY NOTES:

3" CAST IRON ROOF DRAIN ABOVE

EXISTING CEILING

CONNECT 3" CAST IRON DRAIN PIPE TO

NEW ROOF DRAIN ABOVE - SEE A201

AND 1/A802

DROP 3" CAST IRON ROOF DRAIN DOWN

TO UTILITY SPACE ADJACENT TO

ELEVATOR TUNNEL, ROOM 002

METAL STUDS AND DRYWALL

CHASE AROUND VERTICAL 3" CAST IRON

DRAIN. ALIGN CHASE W/ EXISTING DOOR

FRAME TRIM. PROVIDE WOOD BASE TO

MATCH EXISTING. RUN CHASE FLOOR TO

CEILING ALONG EXISTING WALL - EXTEND

EXISTING ELECTRICAL OUTLET TO FACE OF

NEW WALL

CONNECT 3" CI DRAIN TO EXISTING 4"

CAST IRON STORM DRAIN

ELECTRICAL PANEL "F" SEE ICE MELT

SYSTEM SHEET A203

NOTE: EXISTING PLANS SHOWN FOR

REFERENCE, NEW WORK SHOWN CLOUDED

Jensen

6" 1'SCALE: 2'0

2 ROOF DRAIN ICE MELT SYSTEM

21028/A203-2

LOOP HEAT

TRACE CABLE ±

24" DOWN ROOF

DRAIN

TRACON MODEL FPT 130

HEAT TRACE CONTROLLER

ROOF OR WALL MOUNT

WEATHER PROOF J BOX &

DUPLEX OUTLET

J

3 WIRE/20A/120V POWER FROM

PANEL "F"/ 10 AWG IN 3/4" GMC

RUN HEAT TRACE CABLE TO OVERFLOW

DRAIN - LOOP CABLE (2) TIMES AROUND

OVERFLOW DRAIN DOME GRATE. H.T.S.

SELF REGULATING HEATING CABLE

LOOP HEAT TRACE ± 24"

DOWN OVERFLOW DRAIN

SELF REGULATING HEATING CABLE

(6W / FT @ 40° F) PLUG INTO DUPLEX

CONTINUOUS

HEAT TRACE

CABLE ON CABLE

JIG AND FRAME

CONNECT SENSOR TO

J-BOX W/ 1" LIQUID TIGHT

CABLE.

TEMPERATURE

SENSOR

OVERFLOW DRAIN, WHERE OCCURS

ICE MELT PLAN

4'SCALE: 0 16'8'

DRAWING

TITLE

PROJECT NAME

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

(R-10)

REGION TEN

MENDENHALL

GLACIER VISITOR

CENTER ROOF

REPLACEMENT

TONGASS NATIONAL

FOREST

JUNEAU

RANGER DISTRICT

A203.dwg

WJ

BW

WJ

6960.021

ICE MELT SYSTEM

A203

ICE MELT SYSTEM KEY NOTES:

WEATHER PROOF GFCI PROTECTED

JUNCTION BOX AND DUPLEX

RECEPTACLE MOUNTED ON 3/4"

GALVANIZED ELECTRICAL CONDUIT. 12"

ABOVE FINISHED ROOF - SEE 2/A203

WEATHER PROOF GFCI PROTECTED

JUNCTION BOX AND DUPLEX

RECEPTACLE MOUNTED TO WALL 16"

ABOVE FINISHED ROOF

VTR, EXTEND TO BE 12" ABOVE FINISHED ROOF

ROOF DRAIN/OVERFLOW DRAIN

SEE 2/A203 FOR ICE MELT

4 2

ICE MELT SYSTEM:

1. PROVIDE AN ICE MELT SYSTEM DESIGNED TO KEEP ROOF DRAINS AND ROOF OVERFLOWS FROM FREEZING. IT IS TO

AUTOMATICALLY OPERATE WHEN THE AIR TEMPERATURE REACHES BELOW 30 DEGREES AND TURN OFF WHEN

TEMPERATURES REACH 38 DEGREES AND ABOVE, BUT THAT IS FULLY ADJUSTABLE BY BUILDING OPERATORS.

2. SYSTEM TO BE DESIGNED AND SUPPLIED AS AN INTEGRATED SYSTEM BY VALIN CORPORATION INDUSTRIAL HEAT TRACING SOLUTIONS (801-205-3944) . PROVIDE COMPLETE SHOP DRAWINGS OF ALL COMPONENTS OF THE WORK WITH LAYOUT

DRAWINGS SHOWING LOCATIONS AND CONNECTIONS OF ALL COMPONENTS FOR A FULL AND COMPLETE OPERATIONAL SYSTEM. DEMONSTRATE OPERATION OF SYSTEM UPON COMPLETION, MAKING SYSTEM ADJUSTMENTS AS REQUIRED.

3. SYSTEM TO CONSIST OF:

a. ROOF OR WALL MOUNTED ELECTRICAL JUNCTION BOX WITH GFCI PROTECTED DUPLEX OUTLET: AT EACH PAIR OF

ROOF DRAINS AND OVERFLOW DRAINS, CONNECTED TO A SPARE 20 AMP, 120V BREAKER IN EXISTING ELECTRIC PANEL F WITH 3- 10 AGW CONDUCTORS PLUS GROUND IN ¾” EMT. PROVIDE ADDITIONAL JUNCTION BOX IN CEILING ABOVE

ELECTRIC PANEL, FISH MC CABLE DOWN TO WALL TO EXISTING PANEL F.

b. HEAT TRACE CONTROLLER: AT EACH ROOF OR WALL MOUNTED JUNCTION BOX TO ALLOW BUILDING OPERATORS TO SET DESIRED TEMPERATURE RANGE. CONTROLLER TO BE TRACON MODEL FPT 130 WITH NEMA 4XIP66 ENCLOSURE.

CONTROLLER TO INCLUDE OPENINGS FOR INPUT POWER, HEATER CABLE OUTPUT AND SEPARATE OUTPUT FOR

TEMPERATURE SENSOR.

c. HEAT TRACE CABLE: 120V MULTI SHIELDED HEATER CABLE, 6 WATT PER FOOT AT 40 DEGREES F. VALIN CORPORATION

HTS-6 SERIES SELF REGULATING HEATING CABLE. CONNECT TO HEAT TRACE CONTROLLER. RUN HEAT CABLE DOWN

ROOF DRAIN AND OVERFLOW DRAIN APPROXIMATELY 24 INCHES.

d. DE-ICING ARRAY AT EACH ROOF DRAIN CONSISTING OF 6 SLIP FIT DE-ICING JIGS AND FRAME FOR ANCHORING HEAT

CABLE WITHOUT PENETRATING ROOF MEMBRANE. KING MODEL 6RDDJ22.

GENERAL NOTES:

1. PROVIDE ICE MELT SYSTEM @ EACH ROOF

DRAIN AND OVERFLOW DRAIN PER 2/A203

2. CONNECT (2) EA SETS OF ROOF DRAINS TO

SINGLE 120V, 20A WIRE CIRCUIT, HOME RUN

TO ELECTRICAL PANEL "F" ROOM 207 (4)

HOME RUNS TOTAL, SEE GENERAL NOTE 6,

SHEET A202C

3. ICE MELT SYSTEM TO BE AS PROVIDED BY

HEAT TRACE SPECIALISTS, VALIN

CORPORATION, 801-205-3944

4. ALL POWER & CONTROL CONDUIT & WIRING

TO BE ACCOMPLISHED BY ELECTRICAL

CONTRACTOR LICENSED IN THE STATE OF

ALASKA

Jensen

5 CHIMNEY PHOTOGRAPH

21028-A204-5

REINSTALL

EXISTING SS

CHIMNEY FLUE &

CURB

80mil PVC ROOF

MEMBRANE W/

PVC CLAD METAL

ROOF EDGE -

SEE 6/A802 REINSTALL

EXISTING

CAMERA COVER

1x12 SHIP LAP & 1x TRIM TO

MATCH EXISTING

REINSTALL

EXISTING

CAMERA &

WIRING - BY

OWNER

REINSTALL

EXISTING

COMMUNICATIONS

ANTENNAE - BY

OWNER

SCALE: 0 3" 6" 1'

2 CHIMNEY PHOTOGRAPH

21028 A204-2

ADHERED 80mil PVC ROOF

MEMBRANE W/ PVC CLAD ROOF

EDGE

ANTENNAE

STAND BY OWNER

1x12 FASCIA & 1x12 SHIP LAP SIDING W/ 1x4 TRIM TO MATCH EXISTING -

SEE 5/A802

REINSTALL EXISTING FLUE & CURB

ANTENNAE DISH &

COMMUNICATIONS

RECIEVER BY

OWNER

SCALE: 0 3" 6" 1'

3 CHIMNEY PHOTOGRAPH

21028 - A204-3

1x4 TRIM TO

MATCH EXISTING

PVC CLAD

METAL FLASHING

EXISTING SIDING

& TRIM TO REMAIN

SEE 6/AD801

1x12 FASCIA TO

MATCH EXISTING

REPLACE

EXISTING SHIP

LAP SIDING W/

1x12 SHIP LAP

SIDING OVER

"GRACE ICE &

WATER SHIELD)

OVER 1/2" PWD

SHEATHING

SCALE: 0 3" 6" 1'

4 CHIMNEY PHOTOGRAPH

21028 - A204-4

REINSTALL EXISTING

CHIMNEY FLUE & CURB

1x12 FASCIA W/ 1x4 TRIM AND 1x12 SHIP LAP

SIDINGPVC CLAD ROOF EDGE

0 8' 12'SCALE: 2' 4'

1 PLAN VIEW CHIMNEY CAP

21028-A204-1

REINSTALL EXISTING SS

CHIMNEY FLUE & SS CURB

ANTENNAE REINSTALLATION BY OWNER

A204

A204

A204

A204

REINSTALL EXISTING

CAMERA COVER

OVERLAY EXISTING PLYWOOD

CHIMNEY SHEATHING W/

ADHERED 80mil PVC MEMBRANE

A802

NON-PENETRATION

ANTENNAE MOUNT &

ANTENNAE BY OWNER

DRAWING

TITLE

PROJECT NAME

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

(R-10)

REGION TEN

MENDENHALL

GLACIER VISITOR

CENTER ROOF

REPLACEMENT

TONGASS NATIONAL

FOREST

JUNEAU

RANGER DISTRICT

A204.dwg

WJ

BW

WJ

6960.021

PARTIAL PLAN &

EXTERIOR DETAILS

A204

Jensen

NORTH ELEVATION

DRAWING

TITLE

PROJECT NAME

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

(R-10)

REGION TEN

MENDENHALL

GLACIER VISITOR

CENTER ROOF

REPLACEMENT

TONGASS NATIONAL

FOREST

JUNEAU

RANGER DISTRICT

A301.dwg

WJ

BW

WJ

6960.021

EXISTING EXTERIOR

ELEVATIONS

A301

NOT TO SCALE

SOUTH ELEVATION

NOT TO SCALE

NOTE:

PLANS, SECTIONS, OR ELEVATIONS ON THIS

SHEET ARE GRAPHIC REPRESENTATIONS OF

ORIGINAL CONSTRUCTION DOCUMENTS AND

ARE ASSUMED TO ACCURATELY REPRESENT

AS-BUILT CONDITIONS. SCALES ARE

APPROXIMATE, AND EXISTING CONDITIONS

SHOULD BE FIELD VERIFIED.

EXISTING BUILDING ELEVATIONS (FOR REFERENCE ONLY)

'-0

APPROXIMATE ELEVATION

CRANE STAGING AREA

APPROXIMATE ELEVATION OF ATV

ROAD FORWARD OF ELEVATION

Jensen

EAST ELEVATION

DRAWING

TITLE

PROJECT NAME

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

(R-10)

REGION TEN

MENDENHALL

GLACIER VISITOR

CENTER ROOF

REPLACEMENT

TONGASS NATIONAL

FOREST

JUNEAU

RANGER DISTRICT

A302.dwg

WJ

BW

WJ

6960.021

EXISTING EXTERIOR

ELEVATIONS

A302

NOT TO SCALE

WEST ELEVATION

NOT TO SCALE

NOTE:

PLANS, SECTIONS, OR ELEVATIONS ON THIS

SHEET ARE GRAPHIC REPRESENTATIONS OF

ORIGINAL CONSTRUCTION DOCUMENTS AND

ARE ASSUMED TO ACCURATELY REPRESENT

AS-BUILT CONDITIONS. SCALES ARE

APPROXIMATE, AND EXISTING CONDITIONS

SHOULD BE FIELD VERIFIED.

EXISTING BUILDING ELEVATIONS (FOR REFERENCE ONLY)

APPROXIMATE GRADE

AT ATV ROAD

Jensen

3 PARAPET

21028 A801-3

WRAP PARAPET W/ PVC

MEMBRANE FLASHING

3"6"

#12x2" @ 18" OC

CONT CLIP

EXISTING TRIM

TO REMAIN

FILL EXISTING

PARAPET W/

SPRAY FOAM

INSULATION

PERIMETER FASTENERS

PER MEMBRANE MFR

MAX HEIGHT OF

TAPERED INSUL

EXISTING ROOF STRUCTURE

TO REMAIN

METAL PARAPET CAP W/ CONT CLIP

TO MATCH EXISTING RADIUS

EXISTING FASCIA

EXISTING ROOF

EDGE FRAMING &

SIDING

1'

-2

V E

R

IF

Y

#12 HEX HEAD FASTENER W/

EPDM WASHER @ 18" OC

CEDAR CONT

CANT STRIP

ROOF ASSEMBLY,

SEE 1/A801

SCALE: 0 3" 6" 1'

1 TYPICAL ROOF ASSEMBLY

21028/A801-1

1/2" DENS DECK

EXISTING STRUCTURAL

PLYWOOD

V A

R

IE

S

EXISTING VAPOR

BARRIER TO REMAIN

(ASSUMED TO BE

ADHERED ASPHALT)

EXISTING 3x6 WOOD

DECKING WHERE OCCURS

1/2" DENS DECK

MECHANICALLY FASTENED

PER MEMBRANE MFR.

(2) 2" POLYISO

80 MIL PVC

POLYISO TAPER

WHERE SHOWN

DO NOT PENETRATE THRU

WOOD DECK

NOTE: REPAIR OR REPLACE

VAPOR BARRIER WHERE

MISSING OR DAMAGED

DURING ROOF REMOVAL

SCALE: 0 3" 6" 1'

2 STONE PARAPET

12048/A801-2

TYP ROOF

ASSEMBLY - SEE

1/A801, SIM

STONE VENEER

TO REMAIN

CONCRETE

WALL TO

REMAIN

WRAP EXISTING

MEMBRANE

OVER PARAPET

1/2" TRTD PLYWOOD

PARAPET PVC

FLASHING

PERIMETER

FASTENER BY

MEMBRANE MFR, TYP

SEALANT

LAP EXISTING

MEMBRANE OVER

TERMINATION BAR &

SECURE W/ NON-

REACTIVE SEALANT

NON-REACTIVE SEALANT

EXISTING CAP TO

REMAIN

ALUMINUM

TERMINATION

BAR W/ 1/4"

DRIVE PINS AT

18" OC

SCALE: 0 3" 6" 1'

4 PARAPET

21028 A801-4

WRAP PARAPET W/ PVC

MEMBRANE FLASHING

3"

6"

CEDAR CONT

CANT STRIP

CONT CLIP

EXISTING TRIM

TO REMAIN

FILL EXISTING

PARAPET W/

SPRAY FOAM

INSULATION

PERIMETER

FASTENERS PER

MEMBRANE MFR

MAX HEIGHT OF

TAPERED INSUL

EXISTING ROOF

STRUCTURE TO

REMAIN

METAL PARAPET CAP W/

CONT CLIP TO MATCH

EXISTING RADIUS

EXISTING FASCIA

EXISTING ROOF

EDGE FRAMING &

SIDING

1'

-2

V E

R

IF

Y

#12 HEX HEAD

FASTENER W/ EPDM

WASHER @ 18" OC

#12x2"

@ 18" OC

ROOF

ASSEMBLY,

SEE 1/A801

SCALE: 0 3" 6" 1'

6 PARAPET

21028 A801-6

WRAP PARAPET W/ PVC

MEMBRANE FLASHING

3"

6"

CEDAR CONT

CANT STRIP

METAL

FLASHING

AND CONT

CLIP

EXISTING

TRIM

TO REMAIN

FILL PARAPET W/

SPRAY FOAM

INSULATION

PERIMETER

FASTENERS PER

MEMBRANE MFR

MAX HEIGHT OF

TAPERED INSUL

EXISTING ROOF

STRUCTURE TO

REMAIN

METAL PARAPET CAP W/

CONT CLIP

1'

-2

V E

R

IF

Y

EXISTING FASCIA

EXISTING ROOF

EDGE FRAMING &

SIDING

#12 HEX HEAD FASTENER

W/ EPDM WASHER

@ 18" OC

#12x2"

@ 18" OC

ROOF

ASSEMBLY, SEE

1/A801

SCALE: 0 3" 6" 1'

5 CURB (BOILER FLUE SIM)

21028/AD801-5

EXISTING

STRUCTURAL ROOF

DECK

EXISTING CURB

REINSTALL

EXISTING VENT

FLASHING

ROOF ASSEMBLY, SEE

1/A801

(V A

R

IE

S

V E

R

IF

Y I

N F

IE

LD

SPRAY FOAM

INSULATION

REPLACE EXISTING

PLYWOOD SHEATHING

#12 HEX HEAD

FASTENER W/ EPDM

WASHER @ 18" OC

RELIEF AIR VENT

DRAWING

TITLE

PROJECT NAME

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

(R-10)

REGION TEN

MENDENHALL

GLACIER VISITOR

CENTER ROOF

REPLACEMENT

TONGASS NATIONAL

FOREST

JUNEAU

RANGER DISTRICT

A801.dwg

WJ

BW

WJ

6960.021

EXTERIOR DETAILS

A801

Jensen

4 ROOF TO WALL

21028/A802-4

EXISTING STONE

VENEER OVER

EXISTING

CONCRETE WALL

EXISTING ROOF

DECK TO REMAIN

EXISTING 6x6

STEEL LINTEL

TO REMAIN

CONCRETE DRIVE

PIN @ 18" OC AND

TERMINATION BAR

ROOF ASSEMBLY,

SEE 1/A801

(V A

R

IE

S

SCALE: 0 3" 6" 1'

1 TYPICAL ROOF DRAIN (OVERFLOW SIM)

21028/A802-1

REINSTALL EXISTING

GRATE AND CLAMP RING

EXISTING ROOF

DECK & FRAMING

TYP, ROOF

ASSEMBLY, SEE

1/A801

EXISTING PIPING &

PIPE INSULATION

FOAMED IN PLACE

INSULATION AROUND

ROOF DRAIN

EXISTING ROOF DRAIN

BOWL - ADJUST HEIGHT

AS REQUIRED

HEAT CABLE & JIG

- SEE A203

SCALE: 0 3" 6" 1'

3 ROOF TO WALL

21028/A802-3

ROOF

ASSEMBLY

SEE 1/A801,

SIM

REINSTALL

EXISTING 1x12

SIDING

ROOF ASSEMBLY

SEE 1/A801

PARAPET CAP

SEE 4/A801

COUNTER FLASHING

W/ FASTENERS

@12" OC

LAP WEATHER

BARRIER OVER

COUNTER

FLASHING

SEALANT, TYP

#12x2" @ 16" OC

#12 HEX HEAD

FASTENER W/

EPDM WASHER

@ 18" OC

FILL EXISTING

PARAPET W/

SPRAY FOAM

INSULATION

EXISTING BATT

INSUL

SCALE: 0 3" 6" 1'

2 RADIO MAST MOUNT

21028-A802-2

36" TRTD 2x6 NAILER

W/ (2) 3/8"X6" LAGS @

EACH STUD (6) TOTAL

2" GALVANIZED

ANTENNAE MAST

BY OWNER

2 1/2" GALVANIZED

SCHEDULE 40, 3' LONG

PIPE BRACKET

GALVANIZED STEEL

"U" STRAP W/ (2)

3/8"x3" BOLTS

COUNTERSUNK

INTO NAILER,

NAILER CENTERED

OVER (3) STUDS

EXISTING 1x12

SIDING

EXISTING

WEATHER

BARRIER

EXISTING

PWD SHEATHING

EXISTING

WOOD STUDS

EXISTING STUD

@ ±16" OC

6" 1'SCALE: 2'0

5 SECTION @ CHIMNEY

21028-A802/5

ROOF ASSEMBLY

- SEE 1/A801

1x12 SHIPLAP

SIDING OVER

GRACE "ICE &

WATER SHIELD"

OVER 1/2" PWD

SHEATHING

A802

SIM

A802

A802

A802

SIM

REINSTALL SS CAP & FIRE

WRAP PVC MEMBRANE OVER

2x CURB

ROOF

ASSEMBLY

- SEE 1/A801

EXISTING

FRAMING AS

OCCURS

PVC ADHERED

OVER DENSDECK

3"SCALE: 0 6"

ROOF EDGE @ CHIMNEY6

21028/A_802-6

1/2" DENS DECK

PVC FLASHING -

WALL TO MEMBRANE

& PVC CLAD METAL

6"

1/2" PWD WRAP PVC

MEMBRANE OVER

ROOF EDGE

PVC CLAD

METAL EDGE

CONT CLIP

CONT WEATHER

BARRIER

3/4" SHIM

1x12 FASCIA

1x4 TRIM BEYOND

1/2" PWD SHEATHING

1x12 SHIPLAP

EXISTING

FRAMING

FASTENERS PER

MEMBRANE MFR

DRAWING

TITLE

PROJECT NAME

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

(R-10)

REGION TEN

MENDENHALL

GLACIER VISITOR

CENTER ROOF

REPLACEMENT

TONGASS NATIONAL

FOREST

JUNEAU

RANGER DISTRICT

A802.dwg

WJ

BW

WJ

6960.021

EXTERIOR DETAILS

A802

Jensen

2021-10-29T08:25:17-0800
HARVEY HERGETT
L:
2021-10-26T15:16:51-0800
LEONARD JOB
2021-10-26T17:06:48-0800
TRISTAN FLUHARTY
2021-10-27T11:43:13-0800
Jordan Hall
2021-10-27T14:35:36-0800
M. Earl Stewart
2021-10-29T13:14:04-0800
JAMES KING

File details come from the government source that posted it. Updated .