Drawings Final 23May2025.pdf
PDF 7 MB Posted
- Attached to
- BLK NF Spearfish WC Asbestos Abatement
- Solicitation number
- 1240LP25Q0113
About this file
This document is a set of construction design and project documents for an Asbestos Abatement project for a Flammable Storage Building at the Spearfish Work Center in the Black Hills National Forest, managed by the USDA Forest Service, Rocky Mountain Region (R2).
The project involves removing all asbestos transite panels from walls and ceilings of an existing storage building located at the Spearfish Work Center. Key specifications include: removing conduits, lights, and other attachments necessary for asbestos removal, disposing of all asbestos-containing materials, and preparing the building for future demolition. The project documents include detailed site maps, architectural drawings, interior and exterior photographs documenting the asbestos panels, and general notes outlining the scope of work. The project is scheduled for May 2025, with design work completed by personnel including R. Zacher, A. Settle, and R. Adam from the Forest Service's engineering division.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Spearfish WC Flamm Storage Specs Draft Final 15Sept2025.pdf | ||
| Statement-of-Work-Spearfish Asbestos r1.docx | DOCX document | |
| Site Map.pdf | ||
| _1240LP25Q0116.pdf | ||
| WD 2015-5377 r29 20250708.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
/14
/23
:1 6 T
FI
LL
MO
RE
-F
RE
Y C :\U
SE
RS
\T
FI
LL
MO
RE
-F
RE
Y\
BO
X\
B
UI
LD
IN
GS
S
TR
UC
TU
RE
S\
BU
IL
DI
NG
S&
FA
CI
LI
TI
ES
\73
F
AC
IL
IT
IE
S\
PR
OJ
EC
TS
\P
RO
JE
CT
S\
NO
RT
HE
RN
H
IL
LS
P
RO
JE
CT
S\
SP
EA
RF
IS
H
W C
PR
OJ
EC
TS
\S
PE
AR
FI
SH
W
C
SH
OP
R
OO
F
RE
PL
AC
EM
EN
T\
DR
AW
IN
GS
\S
PE
AR
FI
SH
W
C
RO
OF
.D
W G
R2
ROCKY MOUNTAIN REGION
FLAMMABLE
STORAGE
BUILDING
ASBESTOS
ABATEMENT
BLACK HILLS NATIONAL
FOREST
NORTHERN HILLS RANGER DISTRICT
SITE MAP
11/29/2023
B BEAM
T FILLMORE-FREY
A. SETTLE
2 65
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text E
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
ARCHIVE NO.
DRAWING SHEET NO.
United States Department of Agriculture Forest Service
R2
ROCKY MOUNTAIN REGION
FLAMMABLE
STORAGE
BUILDING
ASBESTOS
ABATEMENT
BLACK HILLS NATIONAL
FOREST
NORTHERN HILLS RANGER DISTRICT
INTERIOR PHOTOS
R. ZACHER
DRAWN
A. SETTLE
CHECKED
R. ADAM
PROJECT NO. SHEET 4 OF 5
DATE
MAY 2025
DESIGNER
Asbestos Transite panels on ceiling and wall corner, typical.
Asbestos transite panels on ceiling, typical. Lights and conduit to be removed as necessary and disposed of off-site.
Northwest corner. Southwest corner,.
Asbestos transite panels on walls and ceiling, typical. Lights, conduits, fan and heater to be removed as necessary and disposed off-site. Shelving units, furniture, and other materials wlll be removed by Government prior to Contractor’s work period.
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
ARCHIVE NO.
DRAWING SHEET NO.
United States Department of Agriculture Forest Service
R2
ROCKY MOUNTAIN REGION
FLAMMABLE
STORAGE
BUILDING
ASBESTOS
ABATEMENT
BLACK HILLS NATIONAL
FOREST
NORTHERN HILLS RANGER DISTRICT
EXTERIOR PHOTOS
R. ZACHER
DRAWN
A. SETTLE
CHECKED
R. ADAM
PROJECT NO. SHEET 5 OF 5
DATE
MAY 2025
DESIGNER
Exterior of building. South (front) and west sides.
Exterior of building. South (front) and east sides.
GENERAL NOTES:
1. REMOVE ALL ASBESTOS TRANSITE PANELS COVERING WALLS AND CEILINGS.
2. BUILDING WILL BE DEMOLISHED IN FUTURE. DEMOLITION OF BUILDING IS NOT IN THIS CONTRACT.
3. CONTRACT SHALL REMOVE CONDUIT, LIGHTS, AND OTHER ATTACHMENTS AS NECESSARY FOR ASBESTOS REMOVAL AND
DISPOSE OF AS ASBESTOS-CONTAINING MATERIAL.
4. NO MATERIALS AND EQUIPMENT NEED TO BE REATTACHED.
5. GOVERNMENT WILL REMOVED PORTABLE ITEMS SUCH AS SHELVING, FURNITURE, AND DEBRIS PRIOR TO CONTRACTOR’S
WORK.
Exterior of building, North, (rear) side.
| drawings 1245.pdf |
| Title Sheet.pdf |
| Site Map 2.pdf |
| Sheets and Views |
| Spearfish WC Roof-Site |
| 3531 Spearfish WC Flamm Storage Original Plan 1977.pdf |
| drawings 1245 |
| Photos 5.pdf |
| Slide Number 1 |
| Photos 4.pdf |
| Slide Number 1 |
File details come from the government source that posted it. Updated .