Drawings.pdf
PDF 30 MB Posted
- Solicitation number
- 36C24622B0002
About this file
This document provides details of a federal contract opportunity for construction services. The Department of Veterans Affairs is seeking a contractor to renovate approximately 8,430 gross square feet in Building 1 of the VA Medical Center in Fayetteville, North Carolina. The project involves work on the basement level of the D-wing. The NAICS code for this opportunity is 236220. The size of contracts for this type of work typically ranges up to $39.5 million. This solicitation will be set aside as a total small business opportunity for firms owned by service-disabled veterans. The solicitation number is 36C24622B0002 and will be available on or around November 16, 2021. Interested parties should register on sam.gov and vetsbiz.gov to receive notifications. Questions can be directed to the contracting specialist, Guy K. Brooks, by email only at guy.brooks@va.gov by the response date.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24622B0002 0004.docx | DOCX document | |
| 36C24622B0002 0003.docx | DOCX document | |
| Attch. A - Wage Determination NC20210025 9.10.21.pdf | ||
| Decon Photos Set 2.pdf | ||
| Decon Photos Set 1.pdf | ||
| 36C24622B0002 0002.docx | DOCX document | |
| Decon Photos Set 3.pdf | ||
| 36C24622B0002 0001.docx | DOCX document | |
| Attachment A - Itemized Schedule of Values Cost Breakdown.xlsx | XLSX spreadsheet | |
| 36C24622B0002.docx | DOCX document | |
| Specifications.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FAYETTEVILLE VA MEDICAL
CENTER 2300 RAMSEY ST
FAYETTEVILLE, NC 28301
PROJECT LOCATION
BUILDING #1
1151 Kildaire Farm Rd.
Suite 120 Raleigh, NC 27511 www.acg-pa.com (919)858-7420
108 Benton Lodge Road Suite B Summerville, SC 29485 www.cemsengineering.com (843)875-3637Project Mgr: John Foley (APOGEE)
Joint Venture An Alliance for Success
Revisions: Date
Drawing Title
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
U.S. Department of Veterans Affairs# © COPYRIGHT Apogee - CEMS JV, LLC
PROJECT SITE MAP PROJECT LOCATION MAP
PROJECT IMAGE
PROJECT MANAGER
NC License #: C-1848
/3
/2
:2
:1
A
M
G-001
COVER
1 6DGC
RENOVATE SPS
FAYETTEVILLE VA MEDICAL CENTER
2300 RAMSEY ST FAYETTEVILLE, NC
28301 SEPTEMBER 3, 2021
100% CONSTRUCTION DOCUMENTS
565-19-10219-112
RENOVATE SPS
FAYETTEVILLE VA MEDICAL CENTER 2300
RAMSEY ST FAYETTEVILLE, NC 28301
VA PROJECT #: 565-19-102
WVS
SHEET LIST
SHEET NUMBER SHEET NAME DWG OF DWG
I-431 SIGNAGE PLAN 7 7
FIRE PROTECTION
FX001 FIRE PROTECTION GENERAL INFORMATION 1 4
FX002 BASEMENT FLOOR FIRE PROTECTION PLAN HAZARD AREAS 2 4
FX101 BASEMENT FLOOR FIRE PROTECTION PLAN - PHASE 1 3 4
FX102 BASEMENT FLOOR FIRE PROTECTION PLAN - PHASE 2 4 4
PLUMBING
P-001 PLUMBING GENERAL INFORMATION 1 13
PD101 BASEMENT FLOOR PLUMBING DEMOLITION PLAN - PHASE 1 2 13
PD102 BASEMENT FLOOR PLUMBING DEMOLITION PLAN - PHASE 2 3 13
PD103 BASEMENT FLOOR MEDICAL GAS DEMOLITION PLAN - PHASE 1 4 13
PW101 BASEMENT FLOOR DRAIN, WASTE, AND VENT PLAN - PHASE 1 5 13
PW102 BASEMENT FLOOR DRAIN, WASTE, AND VENT PLAN - PHASE 2 6 13
PW103 FIRST FLOOR / ROOF PLUMBING PLAN - NEW & DEMO WORK 7 13
PP101 BASEMENT FLOOR DOMESTIC WATER PLAN - PHASE 1 8 13
PP102 BASEMENT FLOOR DOMESTIC WATER PLAN - PHASE 2 9 13
PG101 BASEMENT FLOOR MEDICAL GAS PLAN - PHASE 1 10 13
P-501 PLUMBING DETAILS 11 13
P-901 SANITARY PIPE RISERS 12 13
P-902 DOMESTIC PIPE RISERS 13 13
MECHANICAL
M-001 MECHANICAL GENERAL INFORMATION 1 13
MD101 BASEMENT FLOOR MECHANICAL DEMOLITION PLAN - PHASE 1 2 13
MD102 BASEMENT FLOOR MECHANICAL DEMOLITION PLAN - PHASE 2 3 13
MH101 BASEMENT FLOOR HVAC PLAN - PHASE 1 4 13
MH102 BASEMENT FLOOR HVAC PLAN - PHASE 2 5 13
MP101 BASEMENT FLOOR MECHANICAL PIPING PLAN - PHASE 1 6 13
MP102 BASEMENT FLOOR MECHANICAL PIPING PLAN - PHASE 2 7 13
MH401 FIRST FLOOR/ ROOF HVAC PLAN DEMO & NEW WORK 8 13
M-501 MECHANICAL DETAILS 9 13
M-502 MECHANICAL DETAILS 10 13
M-503 MECHANICAL CONTROLS 11 13
M-504 MECHANICAL CONTROLS 12 13
M-601 MECHANICAL SCHEDULES 13 13
ELECTRICAL
E-001 ELECTRICAL GENERAL NOTES, SYMBOL LEGENDS, AND ABBREVIATIONS 1 13
ED101 BASEMENT ELECTRICAL DEMOLITION PLAN - PHASE 1 2 13
ED102 BASEMENT ELECTRICAL DEMOLITION PLAN - PHASE 2 3 13
EP101 BASEMENT ELECTRICAL PLAN - PHASE 1 4 13
EP102 BASEMENT ELECTRICAL PLAN - PHASE 2 5 13
EL101 BASEMENT LIGHTING PLAN - PHASE 1 6 13
EL102 BASEMENT LIGHTING PLAN - PHASE 2 7 13
EL103 BASEMENT LIGHTING PLAN - PHASE 3 8 13
E-401 ELECTRICAL ENLARGEMENTS 9 13
E-501 ELECTRICAL DETAILS 10 13
E-601 ONE-LINE DIAGRAM 11 13
E-602 ELECTRICAL SCHEDULES 12 13
E-603 ELECTRICAL SCHEDULES 13 13
TECHNOLOGY
T-001 TECHNOLOGY GENERAL NOTES, SYMBOL LEGEND, AND ABBREVIATIONS 1 11
T-101 BASEMENT TECHNOLOGY PLAN - PHASE 1 2 11
T-102 BASEMENT TECHNOLOGY PLAN - PHASE 2 3 11
T-111 BASEMENT SECURITY PLAN - PHASE 1 4 11
T-112 BASEMENT SECURITY PLAN - PHASE 2 5 11
T-113 BASEMENT SECURITY PLAN - PHASE 3 6 11
T-114 BASEMENT CCTV CABLING ROUTING PLAN 7 11
T-401 TECHNOLOGY ENLARGEMENTS 8 11
T-501 TECHNOLOGY DETAILS 9 11
T-502 TECHNOLOGY DETAILS 10 11
T-601 TECHNOLOGY RISERS 11 11
FIRE ALARM
FA001 FIRE ALARM GENERAL NOTES, SYMBOL LEGEND, AND RISER 1 3
FA101 BASEMENT FIRE ALARM PLAN - PHASE 1 2 3
FA102 BASEMENT FIRE ALARM PLAN - PHASE 2 3 3
SHEET LIST
SHEET NUMBER SHEET NAME DWG OF DWG
GENERAL
G-001 COVER 1 6
G-002 GENERAL INFORMATION 2 6
G-003 PRE-CONSTRUCTION RISK ASSESSMENT (PCRA) 3 6
G-004 INFECTION CONTROL RISK ASSESSMENT (ICRA) DETAILS 4 6
G-005 PHASING PLANS 5 6
LS101 BASEMENT FLOOR LIFE SAFETY 6 6
CIVIL
C-101 EXISTING CONDITIONS / DEMOLITION AND SITE PLANS 1 3
C-102 LEGEND, ABBREVIATIONS AND DETAILS 2 3
C-103 RAISED TABLETOP CROSSING AND PAVEMENT MARKING DETAILS 3 3
STRUCTURAL
S-001 GENERAL NOTES & DESIGN LOADS 1 12
SD101 PARTIAL DEMOLITION PLANS 2 12
S-101 PARTIAL FOUNDATION PLAN 3 12
S-102 PARTIAL BASEMENT FLOOR FRAMING PLAN 4 12
S-103 PARTIAL FIRST FLOOR FRAMING PLAN 5 12
S-104 PARTIAL SECOND FLOOR AND ROOF FRAMING PLANS 6 12
S-201 ELEVATIONS 7 12
S-301 SECTIONS 8 12
S-302 SECTIONS 9 12
S-303 SECTIONS 10 12
S-401 ENLARGED CART LIFT PLANS 11 12
S-501 DETAILS 12 12
ARCHITECTURAL
AE001 ARCHITECTURAL SYMBOLS, ABBREVIATIONS AND NOTES 1 23
AD101 BASEMENT FLOOR DEMOLITION PLAN - PHASE 1 2 23
AD102 PARTIAL FIRST FLOOR ROOF AND SECOND FLOOR DEMOLITION PLAN - PHASE 1 3 23
AD103 BASEMENT FLOOR DEMOLITION PLAN - PHASE 2 4 23
AD104 BASEMENT FLOOR DEMOLITION PLAN - PHASE 3 5 23
AD110 BASEMENT REFLECTED CEILING DEMOLITION PLAN - PHASE 1 6 23
AD111 BASEMENT REFLECTED CEILING DEMOLITION PLAN - PHASE 2 7 23
AE101 BASEMENT FLOOR PLAN - PHASE 1 8 23
AE102 PARTIAL FIRST FLOOR ROOF NEW WORK AND SECOND FLOOR PLAN PHASE 1 9 23
AE103 BASEMENT FLOOR PLAN - PHASE 2 10 23
AE104 BASEMENT FLOOR PLAN - PHASE 3 11 23
AC110 BASEMENT FLOOR REFLECTED CEILING PLAN - PHASE 1 12 23
AC111 BASEMENT FLOOR REFLECTED CEILING PLAN - PHASE 2 13 23
AC112 BASEMENT FLOOR REFLECTED CEILING PLAN - PHASE 3 14 23
AE201 EXTERIOR ELEVATIONS 15 23
AE401 ENLARGED PLANS 16 23
AE402 AHU ENCLOSURE SECTIONS, DETAILS 17 23
AE403 CART LIFT PLANS, SECTIONS, AND DETAILS 18 23
AE404 CANOPY ELEVATIONS, SECTIONS, DETAILS 19 23
AE501 PARTITION TYPES 20 23
AE502 EQUIPMENT INSTALLATION DETAILS 21 23
AE503 INTERLOCKING PASS-THRU PLAN AND SECTION DETAILS 22 23
AE601 DOOR SCHEDULE, ELEVATIONS AND DETAILS 23 23
INTERIORS
I-001 FINISH SCHEDULES AND LEGEND, GENERAL NOTES, CASEWORK, DETAILS AND
ABBREVIATIONS
1 7
I-401 INTERIOR ELEVATIONS 2 7
I-410 ENLARGED PLANS 3 7
I-411 ENLARGED PLANS 4 7
I-412 SPS EQUIPMENT PLAN AND SCHEDULE 5 7
I-430 ENLARGED TOILET PLANS AND ELEVATIONS 6 7
DocuSign Envelope ID: D7F6D13F-0632-41F8-B963-99AC9916F215
9/7/2021
WALL SECTION
SYMBOL
INTERIOR ELEVATION
SYMBOL
COLUMN GRID
ELEVATION SYMBOL
REVISION NOTE
ENLARGED DETAIL CALLOUT
ROOM DESIGNATION
SYMBOL
BREAK LINE
ROOF SLOPE
DIRECTION SYMBOL
TYPICAL GRAPHIC SCALE
DETAIL #
PAGE #
DETAIL #
PAGE #
TRUE NORTH ARROW
PROJECT NORTH ARROW
A8.1
EXTERIOR ELEVATION
SYMBOL
DETAIL #
PAGE #
A8.1
A8.1
A8.1
BUILDING SECTION
SYMBOL
DETAIL #
PAGE #
A8.1
A8.1
DETAIL SECTION
SYMBOL
DETAIL #
PAGE #
A8.1
WALL GRID
(REPRESENTS
FACE OF EXISTING
WALL)
XX.X
XX.X
ELEVATION
0'-0"
ROOM
NAME
101A
NORTH
PLAN
NORTH
TRUE
0 4 8 16
1. ELIMINATE ALL WORK ASSOCIATED WITH HIGH AND LOW EXTERIOR CANOPIES. ELIMINATE ALL GRADING AND CONCRETE FLAT WORK LOCATED WITHIN EXISTING DRIVE.
2. ELIMINATE TRAILER TR-2 FOR THE ENTIRETY OF PROJECT. ELIMINATE ALL ASSOCIATED WORK FOR THE DESIGN, CONSTRUCTION, AND SUPPLY OF TR-2 ELIMINATE ALL
UTILITY WORK ASSOCIATED WITH TR- 2.
3. ELIMINATE TRAILER TR-1 FOR THE ENTIRETY OF PROJECT. ELIMINATE ALL ASSOCIATED WORK FOR THE DESIGN, CONSTRUCTION, AND SUPPLY OF TR-1 ELIMINATE ALL
UTILITY WORK ASSOCIATED WITH TR-1.
4. ELIMINATE DECON SEALED CART LIFT. INCLUDING CART LIFT, CONSTRUCTION OF HOIST WAY, CUTTING CONCRETE STRUCTURE, ROOFING, AND ALL OTHER ASSOCIATED
WORK.
1-1/2"
DIAMETER
GRAB BAR
TOILET
TISSUE
DISPENSER
SANITARY
NAPKIN
DISPOSAL
TOILET
FIXTURE
TOILET
FIXTURE
TOILET
TISSUE
DISPENSER
1-1/2"
DIAMETER
GRAB BAR
EXPOSED
PLUMBING AT
BARRIER
FREE
LAVATORIES
SHALL BE
INSULATED.
LEVER OPERATING
CONTROLLED
SOAP DISPENSER
NOTE: SINKS IN COUNTERS TO BE
MOUNTED WITH RIM NO MORE
THAN 2'-10" HIGH AND WITH AT
LEAST 2'-3" KNEE CLEARANCE.
CLEAR
ACCESSIBLE TOILET TYPICAL ACCESSIBLE
CLEARANCE AT LAVATORY
TYPICAL ACCESSIBLE
LAVATORY AND MIRROR
1'-3" 1'-3"
M
IN
M A
X
M
A X
M
A X6
A
.F .F
5'-0" CLEAR
3'-0" 6"
3'-0"
" 3
1'-0" 3'-6"
2'-4"
5'-0" CLEAR
MIN
8"
MAX
6"
M
IN9
M
IN
M
IN
M A
X
17" MIN
TYPICAL TOILET NON-ACCESSIBLE
TOILET
TISSUE
DISPENSER
2'-9"
TOILET
FIXTURE
1'-6"
ACCESSIBLE
ROBE/COAT HOOK
ROBE/COAT
HOOK
TELEVISION
OUTLET
WALL MOUNTED TVTOILET ACCESSORIES
6"
F O
R S
T A
N D
IN
G
O
.C
TELEVISION
OUTLET
F O
R S
E A
T E
D
O
.C
PAPER TOWEL
DISPENSER
2'-0" AT SIDEWALLS
AT COUNTER SINKS
1'-6" AT SIDEWALLS
AT LAVATORY
4'-0" MAX TO
HIGHEST OPERABLE
POINT - IF FIRE
EXTINGUISHER
OVER 40 LBS
3'-6" MAX HT.
FIRE EXTINGUISHER
CABINET
ELECTRICAL CABINET
DUPLEX
OUTLET
SWITCH
CARD READER
TELEPHONE OR
DATA OUTLET
FIRE ALARM
PULL
INTERCOM
STATION
DUPLEX
OUTLET
COMPUTER
TERMINAL
MOP BASIN
MOP SHELF
TYPICAL JANITORS CLOSET
FIRE ALARM
CHIME WITH
VISUAL
ALARM LIGHT
FIRE ALARM
PULL STATION
FIRE ALARM
ANNUNCIATOR
FIRE ALARM
WALL PROTECTION
BUMPER GUARD
HANDRAIL
OR DOOR FRAME
3" TO CORNERGUARD
CORNER GUARD
MISC. WALL DEVICES
/2
T O
B O
T T
O M
O F
R
E F
L E
C T
IV
S
U R
F A
C E
O F
M
IR
R
O R
F O
R S
T A
N D
IN
G
O
.C
DSS TV ROUGH
INS FOR J BOXES
DECISION SUPPORT SYSTEM (DSS)
*NOTE FOR MOUNTING OF
WALL-MOUNTED ITEMS:
PROVIDE SUPPLEMENTAL
FRAMING AT WALL OPENINGS
INCLUDING KING STUDS, JACK
STUDS, AND CRIPPLE STUDS,
AS REQUIRED FOR
COMPLETION OF THE WORK.
INTERCOM
STATION
INTERCOM
MASTER
STATION
INTERCOM
WALL
OUTLET
INTERCOM STATION
THERMOSTAT
PUSH BUTTON/PAD
HAND WAVE
O F
R
IM
T
O P
1151 Kildaire Farm Rd.
Suite 120 Raleigh, NC 27511 www.acg-pa.com (919)858-7420
108 Benton Lodge Road Suite B Summerville, SC 29485 www.cemsengineering.com (843)875-3637Project Mgr: John Foley (APOGEE)
Joint Venture An Alliance for Success
Revisions: Date
Drawing Title
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
U.S. Department of Veterans Affairs# © COPYRIGHT Apogee - CEMS JV, LLC
PROJECT MANAGER
NC License #: C-1848
/3
/2
:2
:1
A
M
G-002
GENERAL INFORMATION
2 6DGC, RJ
RENOVATE SPS
FAYETTEVILLE VA MEDICAL CENTER
2300 RAMSEY ST FAYETTEVILLE, NC
28301 SEPTEMBER 3, 2021
100% CONSTRUCTION DOCUMENTS
565-19-10219-112
WVS
GENERAL SYMBOL LEGEND
BID DEDUCT ALTERNATES
Scale: 3/8" = 1'-0"
STANDARD MOUNTING HEIGHTS
INFECTION CONTROL RISK MITIGATION RECOMMENDATIONS MATRIX OF PRECAUTIONS
FOR CONSTRUCTION AND RENOVATION
III/IVLOW Risk Group 1
Class III
Note: Infection Control approval will be required when the Construction Activity and Risk Level indicate that
It is the Contractor's Responsibility to provide the following Infection Control Precautions depending upon the Area Class Designation
II
I
III
MEDIUM Risk Group 2
HIGH Risk Group 3
HIGHEST Risk Group 4 IV
IV
IV
III/IV
III/IV
III
III/IV
I
III
Patient Risk Group Table
Infection Control Matrix - Class of Precautions: Construction Project by Patient Risk
TYPE A
Construction Project Type
Major demolition and construction projects
Includes, but is not limited to:
- activities which require consecutive work shifts
- requires heavy demolition or removal of a complete ceiling system
- new construction
Work that generates a moderate to high level of dust or requires demolition or removal of any fixed building components or assemblies
Includes, but is not limited to:
- sanding of walls for painting or wall covering
- removal of floor coverings, ceiling tiles and casework
- new wall construction
- minor duct work or electrical work above ceilings
- major cabling activities
- any activity which cannot be completed within a single work shift
Small scale, short duration activities which create minimal dust
Includes, but is not limited to:
- installation of telephone and computer cabling
- access to chase spaces
- cutting of walls or ceiling where dust migration can be controlled
Inspection and Non-Invasive Activities
Includes, but is not limited to:
- removal of ceiling tiles for visual inspection limited to 1 tile to 50 square feet
- painting (but not sanding), wall covering
- electrical trim work, minor plumbing, and activities which do not generate dust or require cutting of walls or access to ceilings other than for visual inspection
Type of Construction / Project Activity Table
Group 2 Medium Risk
Group 1 Low Risk
- Bldg. #69 Therapy areas
- Respiratory Therapy
- Outpatient Clinics
- CBOC's
- Mental Health Units
- VACANT AREA ADJACENT TO
OCCUPIED AREA
- Office areas (non-clinical)
- Hallways
- FES/EMS areas
I
Patient Risk Group
TYPE D
TYPE C
TYPE B
TYPE A
Group 4 Highest Risk
Group 3 High Risk
- Pharmacy
- Radiology/ CT Scanner
- Urgent Care
- Laboratories
- CLCs
- SPD; AMCU;
- Respiratory Isolation Rooms
- Surgery
III
TYPE DTYPE CTYPE B
Class IVor control procedures are necessary.
C
LA
S S
IV
C
LA
S
S
II
During Construction Project
C L-
I C
LA
S
S
II
I
1. Remove barrier materials carefully to minimize spreading of dirt and debris associated with construction.
2. Contain construction waste before transport in tightly covered containers.
3. Cover transport receptacles or carts. Tape covering
4. Vacuum work area with HEPA filtered vacuums.
5. Wet mop area with disinfectant after barriers are removed.
6. Remove or isolate HVAC system in areas where work was being performed.
1. Remove barrier materials carefully to minimize spreading of dirt and debris associated with construction.
2. Contain construction waste before transport in tightly covered containers.
3. Cover transport receptacles or carts. Tape covering.
4. Vacuum work with HEPA-filtered vacuums.
5. Wet mop with disinfectant.
6. Remove isolation of HVAC system in areas where work is being performed.
1. Wipe surfaces to remove dust.
Upon Completion of Project
1. Wipe work surfaces with disinfectant.
2. Contain construction waste before transport in tightly covered containers.
3. Wet mop and/or vacuum work area with HEPA filtered vacuum before leaving work areas.
4. Remove isolation of HVAC system in areas where work is being performed.
1. Includes all activities required by Class II
2. Obtain Infection Control Permit from Hospital Safety Officer or Facilities
Management Maintenance and Engineering department before construction begins.
3. Remove or isolate HVAC system in area where work is being done to prevent contamination of duct system.
4. Complete all critical barriers before construction begins or implement control cube method.
5. Maintain negative air pressure within work site utilizing HEPA-equipped air filtration units.
6. Contain construction waste before transport in tightly covered containers.
7. Cover transport receptacles or carts. Tape covers.
8. Wet mop and/or vacuum with HEPA filtered vacuum before leaving work areas.
9. Remove isolation of HVAC system in areas where work is being performed.
1. Execute work by methods to minimize raising dust from construction operations.
2. Immediately replace a ceiling tile displaced for visual inspection.
1. Includes all activities required by Class I
2. Provide active means to prevent airborne dust from dispersing into atmosphere.
3. Water mist work surfaces to control dust while cutting.
4. Seal unused doors with duct tape.
5. Block off and seal air vents.
6. Replace adhesive walk-off mats at entrance and exit of work area. Replace used mats in accordance with manufacturer's recommendations.
7. Remove or isolate HVAC system in area where work is being done to prevent contamination of duct system.
1. Includes all activities required by Class III
2. Obtain Infection Control Permit from Hospital Safety Officer or Facilities
Management Maintenance and Engineering department before construction begins.
3. Isolate HVAC system in areas where work is being done to prevent contamination of duct system.
4. Complete all critical barriers or implement control cube method before construction begins.
5. Maintain negative air pressure within work site utilizing HEPA equipped air filtration units.
6. Seal holes, pipes, conduits, and punctures appropriately.
7. Construct anteroom and require all personnel to pass through this room so they can be vacuumed sing a HEPA vacuum cleaner before leaving work site or they can wear cloth or paper coveralls that re removed each time they leave the work site.
8. All personnel entering work site are required to wear shoe covers. Shoe covers must be changed each time the worker exits the work area.
9. Place adhesive walk-off mats at entrance to work area within anteroom.
10. Replace per manufacturer's recommendations. Do not remove barriers from work area until completed project is inspected each by the Hospital Safety Officer, Facilities Management Maintenance and Engineering Department and thoroughly cleaned by the Hospital Environmental Services Department or their contracted Environmental Service Company Contain construction waste before transport in tightly covered containers.
11. Cover transport receptacles or carts. Tape covering
12. Vacuum work area with HEPA filtered vacuums.
13. Wet mop with disinfectant after barriers are removed.
14. Remove isolation of HVAC system in areas where work is being performed.
CEMENTITIOUS BACKER TO
CONSTRUCTION SIDE
UL U404, 1HR
PAINT
EXISTING FLOOR
A 1-HR RATED AND SMOKE RATED
UL DESIGN NO. U404
UNDERSIDE OF EXISTING
STRUCTURE
CONSTRUCTION
SIDE
FIRE RESISTANT SEALANT,
BOTH SIDES
INTERIM LIFE SAFETY MEASURES IN EFFECT FOR THE
RENOVATE SPS PROJECT
• THIS EXIT IS CLOSED AND LEADS TO A CONSTRUCTION
AREA
• PLEASE USE ALTERNATE EXITS AS MARKED
1'-5"
ICRA, ILSM, FIRE
WATCH AND
MISC. FORMS
PAPER CADDY
POST ICRA, ILSM. FIRE, INSPECTION SHEETS VISIBLE TO PUBLIC
ILSM TEMPORARY BARRIER TAG
PROJECT:
PRIME CONTRACTOR:
SUB CONTRACTOR:
EMERGENCY CONTACT NO.:
BARRIER INSTALLATION DATE:
BARRIER EXPIRATION DATE:
DOOR INFORMATION
NO. QTY. WIDTH HEIGHT THICK TYPE MAT'L TYPE MAT'L DEPTH
FRAME INFORMATION
RATING HRDWR.
MISCELLANEOUS
REMARKS
TD001
(2) CONTRACTOR'S
DISCRETION ON
DOOR WIDTH-
3'-0" MIN.
7'-0" 1 3/4" A HM TYPE I HM 5 3/4" 45 MIN SET 2
DOOR AND FRAME SCHEDULE
NOTE: THIS DOOR AND FRAME SCHEDULE IS FOR RATED TEMPORARY DOORS ONLY. HARDWARE SET 2
HINGES
FLUSH BOLTS
DUST PROOF STRIKE
PASSAGE SET
COORDINATOR
ASTRAGAL
DOOR CLOSER
KICK PLATES
GASKETING
TA2714
ML2010
2600 SERIES
BY DOOR MANUF.
DC6210xA11
K1050F
S888 x HEAD & JAMBS
32D
32D
26D
32D
32D
MK
RO
RO
CO
RO
CO
RO
PE
MANUFACTURERS:
CORBIN RUSSWIN
McKINNEY
PEMKO
ROCKWOOD
NOTE:
HARDWARE MANUFACTURERS LISTED AS BASIS OF DESIGN.
ALTERNATE MANUFACTURERS ACCEPTABLE, SUBJECT TO
REVIEW BY ARCHITECT AND COR FOR EQUAL QUALITY
COMPLIANCE.
TYPE A TYPE I
2" VARIES 2"
TD002
TD003
CONTRACTOR'S
DISCRETION ON
DOOR WIDTH-
3'-0" MIN.
7'-0" 1 3/4" A HM TYPE I HM 5 3/4" 45 MIN SET 1
(2)
(1)
CONTRACTOR'S
DISCRETION ON
DOOR WIDTH-
3'-0" MIN.
7'-0" 1 3/4" A HM TYPE I HM 5 3/4" 45 MIN SET 2
TD004
CONTRACTOR'S
DISCRETION ON
DOOR WIDTH-
3'-0" MIN.
7'-0" 1 3/4" A HM TYPE I HM 5 3/4" 45 MIN SET 2
TD005
TD006
CONTRACTOR'S
DISCRETION ON
DOOR WIDTH-
3'-0" MIN.
7'-0" 1 3/4" A HM TYPE I HM 5 3/4" 45 MIN SET 1
CONTRACTOR'S
DISCRETION ON
DOOR WIDTH-
3'-0" MIN.
7'-0" 1 3/4" A HM TYPE I HM 5 3/4" 45 MIN SET 1(1)
(2)
(1)
(1)
TD006 CONTRACTOR'S
DISCRETION ON
DOOR WIDTH-
3'-0" MIN.
7'-0" 1 3/4" A HM TYPE I HM 5 3/4" 45 MIN SET 1
TD007
TD008
CONTRACTOR'S
DISCRETION ON
DOOR WIDTH-
3'-0" MIN.
7'-0" 1 3/4" A HM TYPE I HM 5 3/4" 45 MIN SET 1
CONTRACTOR'S
DISCRETION ON
DOOR WIDTH-
3'-0" MIN.
7'-0" 1 3/4" A HM TYPE I HM 5 3/4" 45 MIN SET 1
HARDWARE SET 1
HINGES
DUST PROOF STRIKE
LATCH SET
DOOR CLOSER
KICK PLATES
GASKETING
TA2714
VA SPEC F01
DC6210xA11
K1050F
S888 x HEAD & JAMBES
32D
26D
32D
MK
RO
CO
RO
PE
CO
MK
PE
RO
(1)
(1)
TD009 CONTRACTOR'S
DISCRETION ON
DOOR WIDTH-
3'-0" MIN.
7'-0" 1 3/4" A HM TYPE I HM 5 3/4" 45 MIN SET 1
(1)
(2)TD010
TD011
CONTRACTOR'S
DISCRETION ON
DOOR WIDTH-
3'-0" MIN.
CONTRACTOR'S
DISCRETION ON
DOOR WIDTH-
4'-0" MIN.
(2)
2 HINGES ONLY
7'-0" 1 3/4" A HM TYPE I HM 5 3/4" 45 MIN SET 2
7'-0" 1 3/4" A HM TYPE I HM 5 3/4" 45 MIN SET 1
1151 Kildaire Farm Rd.
Suite 120 Raleigh, NC 27511 www.acg-pa.com (919)858-7420
108 Benton Lodge Road Suite B Summerville, SC 29485 www.cemsengineering.com (843)875-3637Project Mgr: John Foley (APOGEE)
Joint Venture An Alliance for Success
Revisions: Date
Drawing Title
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
U.S. Department of Veterans Affairs# © COPYRIGHT Apogee - CEMS JV, LLC
PROJECT MANAGER
NC License #: C-1848
/3
/2
:2
:1
A
M
G-003
PRE-CONSTRUCTION RISK
ASSESSMENT (PCRA)
3 6DGC
RENOVATE SPS
FAYETTEVILLE VA MEDICAL CENTER
2300 RAMSEY ST FAYETTEVILLE, NC
28301 SEPTEMBER 3, 2021
100% CONSTRUCTION DOCUMENTS
565-19-10219-112
WVS
Scale: 3/4" = 1'-0"
ICRA BARRIER WALL TYPES
Scale: 3" = 1'-0"
ILSM SIGNAGE
ILSM TEMPRARY BARRIER TAG
Scale: 1" = 1'-0"
UL-U404
Scale: 1/4" = 1'-0"
ICRA DOOR SCHEDULE
CEMENTITIOUS BACKER
TO CONSTRUCTION SIDE
5/8" GYP BD TYP X
ON BOTH SIDES -
1HR RATED
FLOOR FIN
- AS SCHEDULED
ACCESS DOOR BEYOND
(2) 5/8" GYPD BD TYP X
TEMPORARY
CONSTRUCTION
LIGHTING
FIRST FLOOR
13'-4"
BASEMENT FLOOR
6002162-54 CLG JOISTS @
16" O.C. TYP. BEAR OVER
WALL, EA END
5/8" PLY WD SHEATING
352S162-33 MIN. WALL
STUDS @ 16" O.C. CENTER
UNDER EA CLG JOIST TYP.
FIRE RESISTANT SEALANT,
BOTH SIDES
ACCESS LADDER
FIRE RESISTANT SEALANT
(2) 5/8" GYP BD
TYP X
352S162-33 MIN. WALL
STUDS @ 16" O.C. CENTER
UNDER EA CLG JOIST TYP.
CONT 6007150-54 W/1/2" DIA SLEEVE
ANCHORS AT 32" O.C. TO EX. CMU
CONT 362T150-33
CONT 600T150-54
CONT 362T150-33
CONT 362T150-33
CONT 362T150-33
CONT 362T150-33
CONT 362T150-33
STUDS TIGHT TO EXISTING
FURRING.
HEPA FILTER UNIT IN DEMOLISHED
AREAS; 1 UNIT TO BE PLACED EVERY
1,000 SQFT MAX. CONFIRM WITH
CAMPUS INFECTION CONTROL
DEPARTMENT
FINISHED FLOORING TO BE KEPT
CLEAN. FLOORS NOT BEING REPLACED
MUST BE PROTECTED. COVER WITH
CONSTRUCTION GRADE TEMPORARY
FLOOR PROTECTION.
RUN EXHAUST AIR TO
EXTERIOR OR VA
APPROVED LOCATION
PHASE 2
PROVIDE SINGLE USE DAMPER IN
HEPA UNIT DUCT WHERE DUCT
PENETRATES A RATED WALL.
DAMPER TO MATCH RATING OF
WALL, NOT LESS THAN 1 HR
SWIVEL CASTERS
WITH TWO
LOCKING BRAKES
MOBILE CART
A D
J U
S T
A B
L E
H E
IG
H
T
HEPA NEGATIVE
AIR UNIT
EXISTING WALL
EXISTING CEILING
POST ICRA, ILSM, FIRE
INSPECTION SHEETS
VISIBLE TO PUBLIC
EXISTING WALL SEE
PLANS FOR FIRE RATING
EXISTING DOOR
OPENING
BARRIER WALLS TO
BE TYPE A
A S
R E
Q U
IR
E
D
PROVIDE STICKY MATS (CHANGED
END OF SHIFT OR MORE IF
NECESSARY TO MAINTAIN
CLEANLINESS).
SUPPLY DUCTS EITHER KEEP
RUNNING OR COVER WHEN
RUNNING TO KEEP DUST OUT
COVER ALL RETURNS
AT THE DIFFUSERS
T D
T D
FIRE EXTINGUISHER ON
PORTABLE FLOOR BRACKET
(ILSM MAY REQUIRE MORE
THAN ONE).
FIRE PULL STATION WITH
AUDIO / VISUAL
COORIDOR
BB-01
EXISTING
EXERIOR WALL
T D
COORIDOR
C2.1
EXISTING
GLAZING
BARRIER WALLS
TO BE TYPE A
F O
W
FIRE EXTINGUISHER
ON PORTABLE
FLOOR BRACKET
(ILSM MAY REQUIRE
MORE THAN ONE).
FOW
12'-6"
PROVIDE STICKY MATS
(CHANGED END OF SHIFT
OR MORE IF NECESSARY
TO MAINTAIN
CLEANLINESS).
FIRE PULL
STATION WITH
AUDIO / VISUAL
COORDINATE AIR
FILTRATION METHODS
CONFIRM WITH CAMPUS
INFECTION CONTROL
DEPARTMENT
POST ICRA, ILSM, FIRE
INSPECTION SHEETS
VISIBLE TO PUBLIC
EXISTING
EXERIOR WALL
EXISTING WALL SEE
PLANS FOR FIRE RATING
POST ICRA, ILSM, FIRE
INSPECTION SHEETS
VISIBLE TO PUBLIC
T D
TD007
FOW
3'-6"
MIN
4'-0"
ALIGN ALIGN
FIRE EXTINGUISHER
ON PORTABLE
FLOOR BRACKET
(ILSM MAY REQUIRE
MORE THAN ONE).
FIRE PULL
STATION WITH
AUDIO / VISUAL
BARRIER WALLS
TO BE TYPE A
ZIPPER BARRIER
D.1
PROVIDE STICKY
MATS (CHANGED END
OF SHIFT OR MORE IF
NECESSARY TO
MAINTAIN
CLEANLINESS).
COORDINATE AIR
FILTRATION METHODS
CONFIRM WITH CAMPUS
INFECTION CONTROL
DEPARTMENT
COORIDOR
C2.1
COORIDOR
C2.2
C
C.1
D
9 10 11 12 13
DECON
B081
CART WASH
0081-C
BREAK RM
0068-B
FEMALE
TOILET
0076-B
EXAM RM 5
0074-A
EXAM RM 5
0074-A
EXAM RM 4
0074-D
EXAM RM 4
0074-D
EXAM
RM 2
0074-E
STERILIZERS
TD004
SPD STORAGE /
SUPPLY
MECH
EB-4B
CLEAN PREP
ROOM
68-D
FOW
6'-3" 3'-8 1/2"
1'-2" 8'-6 1/2" 9'-5" 12'-10 1/2" 24'-0" 10'-3" 7'-7" 6'-2"
F O
W
.6
F O
W
/2
T D
/2
G-004
MECH
EB-4A
MECH/ELEC
EB-2
TELECOM
PHASE 1A
352S162-33 MIN. WALL STUDS @
16" O.C. CENTER UNDER EA
CLG JOIST TYP.
BOX BEAM OVER
DOOR TYP.
3 5/8" BOX BEAM BEARING
ON WALL TRY W (2)
STUDS MIN. BELOW
BEARING TYP.
2x2x0-4x54 MIL JOIST TO
BEAM CONN. ANGLE W/ (3)
#12 SCREWS EA LEG TYP.
SPD
6002162-54 CLG JOISTS @
16" O.C. TYP.
(2) 600S162-54 BOX BEAM
W/ 362T150-33 TRACK TOP
& BOT.
PROVIDE 3'-0"W x 4'-0"H 45
MIN RATED DOOR &
FRAME "TD011"
G-004
G-004
G-004
SIM
SIM
/2
/2
F O
W
TEMPORARY
WALL
FINISHED FLOOR
- AS SCHEDULED
(2) GYP BD TYP X
EXISTING WALL
352S162-33 MIN. WALL
STUDS @ 16" O.C.
CENTER UNDER EA
CLG JOIST TYP.
CONT 362T150-33
1151 Kildaire Farm Rd.
Suite 120 Raleigh, NC 27511 www.acg-pa.com (919)858-7420
108 Benton Lodge Road Suite B Summerville, SC 29485 www.cemsengineering.com (843)875-3637Project Mgr: John Foley (APOGEE)
Joint Venture An Alliance for Success
# KEY NOTES:
Revisions: Date
Drawing Title
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS:
WALL RATING LEGEND
1 HR - FIRE BARRIER
2 HR - FIRE BARRIER
SMOKE RESISTIVE HAZARDOUS AREA
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
U.S. Department of Veterans Affairs# © COPYRIGHT Apogee - CEMS JV, LLC
S S S S
PROJECT MANAGER
/3
/2
:2
:2
A
M
G-004
INFECTION CONTROL RISK
ASSESSMENT (ICRA) DETAILS
4 6DGC
RENOVATE SPS
FAYETTEVILLE VA MEDICAL CENTER
2300 RAMSEY ST FAYETTEVILLE, NC
28301 SEPTEMBER 3, 2021
100% CONSTRUCTION DOCUMENTS
565-19-10219-112
WVS
Scale: 1/2" = 1'-0"
ICRA BARRIER
Scale: 1/2" = 1'-0"
PHASE 2 ICRA DIAGRAM
Scale: 1/2" = 1'-0"
MOBILE CONTAINMENT CART
Scale: 1/2" = 1'-0"
ICRA VESTIBULE BASEMENT FLOOR
Scale: 1/2" = 1'-0"
ICRA VESTIBULE FIRST AND SECOND FLOOR - GLAZING
REPLACEMENT
Scale: 1/2" = 1'-0"
ICRA VESTIBULE SECOND FLOOR
1 EXISTNG DOOR TO REMAIN SHUT
2 EXTEND EXISTING WALL TO UNDERSIDE OF
DECK CONSTRUCT AS 1 HR BARRIER.
FIRESTOP ALL PENETRATIONS TO
MAINTAIN RATING.
Scale: 1/4" = 1'-0"
ENLARGED PLAN ICRA WALL AND FRAMING PLAN - PHASE 1
Scale: 1 1/2" = 1'-0"
SECTION DETAIL - PHASE 1 ICRA WALL
UP DN
DN
DN
UP DN
DN
DN
UP DN
DN
DN
CLEAN PREP
RM
68-D
COMPRESSOR
RM
68-6
DECON
B081
CART WASH
0081-C
FEMALE
LOCKER
80-B
LOUNGE AREA
MALE LOCKER
80-A
ELECTRICAL
CLOSET
EB-1
B09B06 GROUP RM
EMPTY
B07
TELERETINAL
IMAGING
OFFICE
B08
HAC
0068-A
OFFICE
TELECOM
CLOSET
TB-2
ELEVATOR
MACH RM
ELEVATOR
MECH RM
0068-F
OFFICE
0068-C
SPD STORAGE / SUPPLY
LOGISTICS
AREA OF WORKNEW LOCATION FOR
RELOCATED NITROGEN
TANKS
1D
1B
1A
1A
TR-2
1A
TR-1
1C
1B
ELEVATOR
ELEVATOR
ELEVATOR
SPD STORAGE
/ SUPPLY
(TEMP)
TR-1
LOGISTICS
ADMIN (TEMP)
TR-2
STAIR
BB-03A
G-004
MECH
EB-4A
MECH
EB-3
MECH
EB-4B
MECH/ELEC
EB-2
1. PHASES SHOWN ARE PROVIDED AS A
SUGGESTED SEQUENCE FOR THE
CONTRACTOR, TO ENSURE CONTINUOUS
OPERATION AND ACCESS TO STERILIZING
EQUIPMENT DURING CONSTRUCTION.
2. THE CONTRACTOR SHALL PROVIDE A
CONSTRUCTION SEQUENCING AND STAGING
PLAN TO THE VA COR FOR APPROVAL,
COORDINATED WITH THE CONSTRUCTION
SCHEDULE.
3. THE CONTRACTOR'S SEQUENCING AND
STAGING PLAN SHALL INCLUDE
CONTRACTOR STAGING AREAS, STORAGE,
DUMPSTER LOCATIONS, AND CONSTRUCTION
ROUTE.
4. CONTRACTOR'S FIELD CONSTRUCTION
TRAILER COORDINATE ACCEPTABLE
LOCATION WITH COR. ALL UTILITIES NEEDED
FOR TRAILER TO BE BY CONTRACTOR
ELECTRICAL CAN BE PULLED FROM CLOSEST
VA PANEL HAVING CAPACITY.
PARTITION WALL
DEMOLITION
PHASE 1A
PHASE 1B
PHASE 1C
PHASE 1D
AREA OF CONSTRUCTION
MECH
EB-2
MECH/
ELECTRICAL
EB-1
B09B06
MORGUE
B05
COOLERS
LOGISTICS
ADMIN.
BREAK
ROOM
LOCKER
ROOM
RESTROOM
RESTROOM
LOGISTICS
SUPERVISOR
ANTE
BREAKDOWN
TELECOM
SPS
CHIEF
118 119
ASST. SPS
CHIEF
SPS
ADMIN
MENS
WOMENS
DETERGENT
COMMON/
LOCKERS
112 ANTE
ROOM
ANTE
ROOM
DECON
SCOPE
CLEAN
PREP
CART
DRYING
HAC
AREA OF WORK
GROUP RM
EMPTY
B07
TELERETINAL
IMAGING
OFFICE
B08ELEVATOR
ELEVATOR
ELEVATOR
VESTIBULE
HAC
0068-A
OFFICE
ELEVATOR
MACH RM
TELECOM
CLOSET
SPD
STORAGE
/ SUPPLY
CLEAN
STORAGE
STAIR
BB-03A
MECH
EB-2
MECH/
ELECTRICAL
EB-1
B09B06
BREAK
DOWN
PH 2
LOGISTICS
MORGUE
B05
COOLERS
ELEVATOR
AREA OF WORK
HAC
0068-A
OFFICE
ELEVATOR
MACH RM
TELECOM
CLOSET
GROUP RM
EMPTY
B07
TELERETINAL
IMAGING
OFFICE
B08
ELEVATOR
ELEVATOR
SPD STORAGE
/ SUPPLY
(TEMP)
TR-1
LOGISTICS
ADMIN (TEMP)
TR-2
STAIR
BB-03A
PHASE 1A
CONTRACTOR TO ACQUIRE AND
INSTALL (2) TRAILERS AND HAVE
OPERATIONAL PRIOR TO COMMENCING
ANY WORK IN THE INTERIOR OF THE
BUILDING.
CONSTRUCT NEW TELECOM ROOM 121.
WORK TO TAKE PLACE OFF HOURS
AND NOT OBSTRUCT PATH TO
EXISTING CLEAN ROOM.
CONSTRUCT NEW TEMPORARY
PARTITION WALL AT SOUTH OF
EXISTING SPD STORAGE/SUPPLY AND
PROCEED WITH DEMOLITION AS
SHOWN ON AD101.
PHASE 1B
DEMOLISH EXISTING ELEVATOR
MACHINE ROOM D068-F AND OFFICE
D068-C. WORK TO TAKE PLACE OFF
HOURS. REMOVE ALL EXISTING
ELEVATOR EQUIPMENT, INCLUDING
CAB. INSTALL NEW HOIST WAY
OPENING IN NORTH WALL, REMOVE
EXISTING HOIST WAY OPENING AT
SOUTH WALL AND FILL IN OPENING.
INSTALL NEW ELECTRIC TRACTION
CART LIFT. CART LIFT MUST BE
OPERATIONAL PRIOR TO COMPLETION
OF PHASE 1C.
CONSTRUCT TEMPORARY PARTITION
AS SHOWN ON AD101. ISOLATE AND
SEAL AREA FROM CORRIDOR.
DEMOLISH ALL WORK AS SHOWN ON
AD101 WITHIN ISOLATED AREA.
PHASE 1C
CONSTRUCT NEW SPS AREA AS
SHOWN ON AE102. ALL WORK WITHIN
THIS AREA TO BE 100% COMPLETE AT
THE END OF THIS PHASE. ALL
EQUIPMENT INSTALLED,
DECONTAMINATION AND CLEAN
PREPARATION MUST BE OPERATIONAL
AT THE END OF THIS PHASE. ALL WORK
INVOLVING CART LIFT SHAFTS
CONSTRUCTION TO BE COMPLETED,
CART LIFTS MUST BE OPERATIONAL AT
THE END OF THIS PHASE.
CONSTRUCTION OF NEW NITROGEN
STORAGE AREA AT THE NORTH WALL
OF EXISTING MECH. ROOM AND
PERFORM ALL REQUIRED PIPING
WORK, RELOCATE EXISTING STAFF TO
NEW AREA WITH MINIMAL DOWNTIME.
INSTALL ALL EQUIPMENT AT R.O. ROOM
129 AND PERFORM ALL ASSOCIATED
WORK.
PHASE 1D
DEMO EXISTING FINISHES IN THIS AREA
AND INSTALL NEW FINISHES. WORK TO
TAKE PLACE OFF HOURS. ACCESS TO
EXISTING CLEAN ROOM MUST BE
MAINTAINED. SPD STORAGE/SUPPLY
WILL STILL BE IN OPERATION.
COORDINATE SEQUENCE OF WORK
FOR MINIMAL DISRUPTION.
AT THE COMPLETION OF PHASE 1, NEW
SPS MUST BE COMPLETELY FINISHED
AND OPERATIONAL, INCLUDING NEW
CART LIFT, HVAC SYSTEMS, AND
WATER SUPPLIES.
PHASE 2A
DEMO ALL WORK IN AREA ON AD103. NOTE: HAZARDOUS ABATEMENT WORK TO BE PERFORMED FIRST.
PHASE 2B
CONSTRUCT NEW AREA AS SHOWN ON AE103. EGRESS MUST BE MAINTAINED TO THE WEST FOR
STERILE STORAGE.
PHASE 3
CONSTRUCT EXTERIOR WORK INCLUDING HIGH AND LOW CANOPIES, CIVIL WORK, CONCRETE WALK, ETC.
COORDINATE ANY DRIVE OBSTRUCTION WITH COR. VEHICLE ACCESS TO MORGUE NEEDS TO BE MAINTAINED.
DIRECT LOGISTICS ROUTE BLOCKED DURING THIS PHASE WAREHOUSE TO STERILE STORAGE ROUTE DENOTED.
1151 Kildaire Farm Rd.
Suite 120 Raleigh, NC 27511 www.acg-pa.com (919)858-7420
108 Benton Lodge Road Suite B Summerville, SC 29485 www.cemsengineering.com (843)875-3637Project Mgr: John Foley (APOGEE)
Joint Venture An Alliance for Success
Revisions: Date
Drawing Title
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS:
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE BARRIER
2 HR - FIRE BARRIER
SMOKE RESISTIVE HAZARDOUS AREA
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
U.S. Department of Veterans Affairs# © COPYRIGHT Apogee - CEMS JV, LLC
S S S S
PROJECT MANAGER
NC License #: C-1848
/3
/2
:2
:4
A
M
G-005
PHASING PLANS
5 6DGC, RJ
RENOVATE SPS
FAYETTEVILLE VA MEDICAL CENTER
2300 RAMSEY ST FAYETTEVILLE, NC
28301 SEPTEMBER 3, 2021
100% CONSTRUCTION DOCUMENTS
565-19-10219-112
WVS
N
KEY PLAN
SCALE: NO SCALE
BUILDING 1
SCOPE OF WORK AREA OF WORK
Scale: 1/16" = 1'-0"
BASEMENT FLOOR PHASING PLAN - PHASE 1
PHASING NOTES
Scale: 1/16" = 1'-0"
BASEMENT FLOOR PHASING PLAN - PHASE 3
0 8 16 32
NORTH
PLAN
0 8 16 32
NORTH
PLAN
0 8 16 32
NORTH
PLAN
Scale: 1/16" = 1'-0"
BASEMENT FLOOR PHASING PLAN - PHASE 2
TEMPORARY TRAILER REQUIREMENTS
CONTRACTOR TO FURNISH AND INSTALL MODULAR TRAILERS IN A DESIGN/BUILD DELIVERY METHOD WITH A MODULAR TRAILER VENDOR OF THEIR CHOICE. TRAILERS MUST BE IN PLACE AND OPERATIONAL PRIOR TO ANY WORK TAKING PLACE IN THE BUILDING. ESTIMATED DURATION TRAILERS WILL BE NEEDED - 12 MONTHS. PRIOR TO THE CONSTRUCTION OF MODULAR TRAILERS, CONTRACTOR TO REVIEW SPACE PROGRAMS AND TECHNICAL REQUIREMENTS WITH COR
AND VA STAKEHOLDERS.
THE FOLLOWING GENERAL LIST OF MINIMUM REQUIRED "SPACE LAYOUTS AND TECHNICAL REQUIREMENTS" IS FOR REFERENCE ONLY AND IS INTENDED FOR BIDDING ASSISTANCE ONLY. IT IS NOT TO BE CONSTRUED AS THE FINAL "BILL OF
MATERIALS" OR DESIGN OF TEMPORARY TRAILERS.
CONTRACTOR RESPONSIBLE FOR PROVIDING SHOP DRAWINGS OF TRAILERS SHOWING LAYOUT AND CONFORMANCE TO ALL VA SPECIFIED REQUIREMENT TO VA FOR APPROVAL PRIOR TO CONSTRUCTION AND DELIVERY AND
INSTALLATION OF TRAILERS.
SPACE LAYOUT AND TECHNICAL REQUIREMENTS
BASIS OF DESIGN
WILLIAMS SCOTSMAN OR EQUAL
19-112-Q13 FAYETTEVILLE VA
TR-2 TRAILER 2
LOGISTICS ADMINISTRATION TRAILER
SIZE: 10' X 46'
TRAILER TO ACCOMMODATE THE FOLLOWING:
SPACE PROGRAM
6 WORKSTATIONS
EACH WORKSTATION TO HAVE POWER AND DATA.
VA WILL PROVIDE FURNITURE, MODULAR VENDOR PROVIDE RECEPTACLES.
BREAK ROOM
RECEPTACLE FOR A VA SUPPLIED REFRIGERATOR (PROVIDE WATER LINE REQUIRED FOR ICE) AND RECEPTACLE FOR MICROWAVE. 8' MINIMUM OF COUNTER SPACE AT 34" AFF WITH BASE CABINETS. (2) 4 DRAWER UNITS, (2) STORAGE
UNITS - LAYOUT AS PER VA.
WATER LINE AND SANITARY TO TRAILERS INCLUDED IN CONSTRUCTION DOCUMENTS.
PROVIDE INSTANT HOT WATER HEATER IN THE CABINETRY.
NO UPPER CABINETS REQUIRED.
BREAK ROOM TO BE DESIGNATED ENCLOSED ROOM, COORDINATE WITH VA.
PROVISION FOR WI-FI: VA TO SUPPLY ROUTER AND RUN TEMPORARY DATA LINE FROM CAMPUS.
TRAILER TO HAVE TWO ENTRY DOORS WITH ONE BEING ACCESSIBLE, ALL DOORS TO HAVE CARD READER ACCESS
FROM OUTSIDE.
ALL DOORS TO HAVE ADA COMLIANT RAMP (FOR PUSHING CARTS, REVIEW WITH VA). ALL RAMPS TO HAVE OVERHEAD
WEATHER PROTECTION (WALKWAY COVER).
FINISHED: FLOOR - LVT
CEILING - ACOUSTICAL CEILING TILE, BASIS OF DESIGN: ARMSTRONG ORTEGA, 769, 2X4
MINIMUM CEILING HEIGHT - 8'-0"
WALLS - PAINTED GYPSUM OR FRP
ELECTRICAL
100A FEED TO TRAILER
GENERAL POWER
LIGHTING THROUGHOUT - LED DIRECT INDIRECT 2X4 - 20 FOOT CANDLES THROUGHOUT
HVAC
TRAILER TO HAVE ITS OWN SELF CONTAINED UNIT CAPABLE OF BOTH HEATING AND COOLING - ALL ELECTRIC
UNIT TO BE ATTACHED TO TRAILER (ROOF MOUNT)
UNIT TO BE CAPABLE OF MAINTAINING 70 DEGREES HEATING, 75 DEGREES COOLING.
SINGLE ZONE, 4 AIR CHANGES PER HOUR, HUMIDITY 20-60%
MERV 11
TR-1 TRAILER 1
SPD STORAGE / SUPPLY
SIZE: 10' X 46'
TRAILER TO ACCOMMODATE THE FOLLOWING:
SPACE PROGRAM
ONE OPEN SPACE
PROVISION FOR WI-FI: VA TO SUPPLY ROUTER AND RUN TEMPORARY DATA LINE FROM CAMPUS.
TRAILER TO HAVE TWO ENTRY DOORS WITH ONE BEING ACCESSIBLE. ALL ACCESS DOORS TO HAVE CARD
READER TO OUTSIDE FOR ACCESS AND DOOR OPERATOR, PUSH BUTTON FROM INTERIOR.
ALL DOORS TO HAVE ADA COMLIANT RAMP (FOR PUSHING CARTS, REVIEW WITH VA). ALL RAMPS TO HAVE
OVERHEAD WEATHER PROTECTION (WALKWAY COVER).
FINISHED: FLOOR - WELDED SEAM
CEILING - ACOUSTICAL CEILING TILE, BASIS OF DESIGN: ARMSTRONG ULTIMA HEALTH ZONE OR
EQUAL 2X2
WALLS - FRP, BASIS OF DESIGN, MARLITE INDURO, SMOOTH OR EQUAL
ELECTRICAL
100A FEED TO TRAILER
GENERAL POWER - RECEPTACLES, POWER AND DATA, SPACED 15' OC MAX
COORDINATE WITH COR FOR ADDITIONAL SPECIAL REQUIREMENTS
LIGHTING THROUGHOUT - LED DIRECT INDIRECT 2X4, 50 FOOT CANDLES THROUGHOUT
HVAC
TRAILER TO HAVE ITS OWN SELF CONTAINED UNIT CAPABLE OF BOTH HEATING AND COOLING -
ALL ELECTRIC
UNIT TO BE ATTACHED TO TRAILER (ROOF MOUNT)
UNIT TO BE CAPABLE OF MAINTAINING 70 DEGREES HEATING, 70 DEGREES COOLING.
SINGLE ZONE, 4 AIR CHANGES PER HOUR, HUMIDITY 20-60%
MERV 14
WORK SHOWN INCLUDES BUT NOT LIMITED TO SHEET AD103, AD111, AE103, AC111
WORK SHOWN INCLUDES BUT NOT LIMITED TO SHEET AD104, AE104
R
F
UP DN
FC
DN
DN
E.1
A
B
B.1
B.2
C
C.1
D
D.1
E
F
F.1
5 6 9 10 11 12 13 14 15 16
A.2
A.1
G
ELECTRICAL
CLOSET
EB-1
B09B06
GROUP RM
EMPTY
B07
TELERETINAL
IMAGING
OFFICE
B08
ELEVATOR
MACH RM
LOGISTICS
ADMIN.
LOGISTICS
SUPERVISOR
ANTE
RESTROOM
RESTROOM
LOCKER
ROOM
BREAK
ROOM
BASEMENT FINISH FLOOR
0'-0"
BREAKDOWN
DECON
CLEAN
PREP
SCOPE
SPARE
HAC
ANTE
ROOM
ANTE
ROOM
COMMON/
LOCKERS
MENS
SPS
ADMIN
SPS
CHIEF
TELECOM
ASST. SPS
CHIEF
IT
CLOSET
TB-1
CART
DRYING
DETERGENT
101A
B
A
A
B
111A
A
111B
123B
123A
B
A
WOMENS
STOR
CLEAN
STORAGE
FEMALE
TOILET
STAIR
WAITING AREA
TRIAGE
NURSE MGR
OFFICE
B-11D
CORRIDOR
B-11A
B-11C
AREA OF WORK
CART
WASHING
CART
COOLING
PHASE 2B
RO
ROOM
B
SPD STORAGE /
SUPPLY
CR
CR
CR
CR
FEC
FEC
FEC
FEC
FEC
FEC
B
HAC
TELECOM
CLOSET
TB-2
VESTIBULE
MECH/ELEC
EB-2
MECH
EB-3
MECH
EB-4A
MECH
EB-4B
CORRIDOR
BB-01
CORRIDOR
BB-02
CORRIDOR
BB-03
CR
CR
CR
CR
CR
PB
CR
CR
HW
HW
HW HW
HW HW
PB
PB
PB
POLICE /
SECURITY RM
VESTIBULE
ACTUE BEDS
E/R CHECK-IN
INTAKE
EXAM
EXAM
EB-2
BREAK RM
LOCKER
0026-A
INFOS
OFFICE
HEALTH
BENEFITS
0027-A
TRAVEL DISTANCE C = 145'-9"
TRAVEL DISTANCE A = 75'-0"
ACTUAL
OCCUP: 8
ACTUAL
OCCUP: 8
A
C
D
TRAVEL DISTANCE C = 52'-4"
TRAVEL DISTANCE A = 272'-9"
TRAVEL DISTANCE B = 232'-4"
TRAVEL
DISTANCE
C = 41'-4"TRAVEL
DISTANCE
D =12'-0"
CA
CA
CA CA
CA
CA
CA
CA
CALC.
OCCUP: 7
CA ACTUAL
OCCUP: 5
G3.0G3.0F3.0 F3.0
F3.0
G3.0
G3.0G3.0
G3.0
F2.0
F2.0
F2.0 F2.0
G3.0G3.0
G3.0
G3.0G3.0
G3.0 G3.0G3.0
G3.0
G3.0G3.0
G3.0
G3.0
G3.0
G6.1
F3.0
G3.0G3.0
G3.0G3.0
G3.0
G3.0H
G3.0G3.0
G3.1
G6.1
G3.0
G3.1
CA
ACTUAL
OCCUP: 7
PB
STAIR
B-10
TRAVEL DISTANCE B TO
SOUTH EXIT = 247'-6" B
PB
PB
CR
PB
CR
CR
CART LIFT
CL2
CART LIFT
CL1
A. SEE SHEETS G-002 & A-001 FOR SYMBOLS AND
ABBREVIATIONS.
B. REFER TO PLUMBING DRAWINGS FOR
INFORMATION CONCERNING PLUMBING FIXTURES
AND PIPING SYSTEM(S).
C. REFER TO MECHANICAL DRAWINGS FOR
INFORMATION CONCERNING HVAC SYSTEM(S).
D. REFER TO ELECTRICAL DRAWINGS FOR
INFORMATION CONCERNING POWER, LIGHTING
AND COMMUNICATION SYSTEM(S).
E. REFER TO ELECTRICAL DRAWING FOR FIRE
ALARM NOTIFICATION AND EMERGENCY EGRESS
LIGHTING LOCATIONS.
F. REFER TO PARTITION TYPES FOR FURTHER FIRE
SEPARATION REQUIREMENTS.
G. CONTRACTOR TO PROVIDE ALL ADDITIONAL
FRAMING NECESSARY FOR ALL OPENINGS AND
SUPPLEMENTAL FRAMING ABOVE PARTITIONS.
H. ALL FIRE RATED ASSEMBLIES SHALL BE
INSTALLED IN STRICT ACCORDANCE WITH
TESTED ASSEMBLIES INDICATED.
I. EXTEND FIRE RATED PARTITIONS, BARRIERS, AND
OTHER SEPARATIONS TO BOTTOM OF
ROOF/FLOOR DECK ABOVE (OR AS DIRECTED BY
UL ASSEMBLY) AND TO EXTERIOR WALL. SEAL
JOINT BETWEEN EDGES OF PARTITION WITH FIRE
RATED SEALANT AND/OR INTUMESCENT
ASSEMBLY.
J. ALL PENETRATIONS OF FIRE-RATED ASSEMBLIES
SHALL BE FIRE-SEALED IN ACCORDANCE WITH
APPROVED MANUFACTURER'S DETAIL FOR
LOCATION, TYPE OF CONSTRUCTION,
PENETRATING ITEM AND RATING REQUIRED.
K. ALL DUCTWORK, DIFFUSERS AND GRILLES
PENETRATING FIRE-RATED WALLS, CEILINGS AND
FLOORS SHALL HAVE THE APPROPRIATE TYPE OF
FIRE/SMOKE DAMPER IN ACCORDANCE WITH THE
TYPE OF CONSTRUCTION BEING PENETRATED
AND THE FIRE/SMOKE RATING REQUIRED.
L. ALL LIGHT FIXTURES AND ELECTRICAL DEVICES
PENETRATING FIRE-RATED ASSEMBLIES SHALL BE
UL-LISTED FOR INSTALLATION IN THE ASSEMBLY
OR SHALL BE INSTALLED SUCH THAT THE FIRE-
RATING IS NOT COMPROMISED.
M. SMOKE RESISTANT CONSTRUCTION SHALL MEET
THE REQUIREMENTS OF ALL APPLICABLE CODES.
AREA SHALL BE SEPARATED FROM THE
REMAINDER OF THE BUILDING BY CONSTRUCTION
CAPABLE OF RESISTING THE PASSAGE OF
SMOKE.
N. STORAGE OF ANY FLAMMABLE OR COMBUSTIBLE
LIQUIDS IS UNDERSTOOD TO NOT BE WITHIN THE
BUILDING. STORAGE OF ANY MATERIAL IS TO BE
IN COMPLIANCE WITH ALL APPLICABLE CODES
AND AUTHORITIES HAVING JURISDICTION.
O. MAINTAIN FIRE CONSTRUCTION BARRIER DURING
ALL DEMOLITION AND CONSTRUCTION. SEE
SHEETS AD101 THRU AD104 AND AE101 THRU
AE104. COORDINATE BARRIER REMOVAL WITH VA
LIFE SAFETY OFFICER.
P. SEE SHEET G-003 FOR TEMPORARY PARTITION
TYPES USED DURING PHASING.
Q. SEE SHEET AE501 FOR PARTITION TYPES.
EGRESS PATH
FIRE EXTINGUISHER CABINET
EMERGENCY RESPONSE REFERENCE
CONTROLLED ACCESS - ALWAYS
UNLOCKED IN DIRECTION OF EGRESS
DELAYED EGRESS W/ ALARM
CA
DE
FEC
1151 Kildaire Farm Rd.
Suite 120 Raleigh, NC 27511 www.acg-pa.com (919)858-7420
108 Benton Lodge Road Suite B Summerville, SC 29485 www.cemsengineering.com (843)875-3637Project Mgr: John Foley (APOGEE)
Joint Venture An Alliance for Success
Revisions: Date
Drawing Title
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS:
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE BARRIER
2 HR - FIRE BARRIER
SMOKE RESISTIVE HAZARDOUS AREA
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
U.S. Department of Veterans Affairs# © COPYRIGHT Apogee - CEMS JV, LLC
S S S S
PROJECT MANAGER
NC License #: C-1848
/3
/2
:2
:5
A
M
LS101
BASEMENT FLOOR LIFE SAFETY
6 6DGC
RENOVATE SPS
FAYETTEVILLE VA MEDICAL CENTER
2300 RAMSEY ST FAYETTEVILLE, NC
28301 SEPTEMBER 3, 2021
100% CONSTRUCTION DOCUMENTS
565-19-10219-112
WVS
N
KEY PLAN
SCALE: NO SCALE
BUILDING 1
SCOPE OF WORK AREA OF WORK
Scale: 1/8" = 1'-0"
BASEMENT FLOOR LIFE SAFETY PLAN
LIFE SAFETY GENERAL NOTES
PROPOSED USE:
OWNED BY: PRIVATE
LOCAL GOVERNMENT
CITY/COUNTY
STATE
FEDERAL
CODE ENFORCEMENT JURISDICTION: CITY
COUNTY
FEDERAL
APPLICABLE CODES:
GENERAL CODE INFORMATION:
NEW CONSTRUCTION
RENOVATION (EXISTING BUILDING)
CONSTRUCTION TYPE:
MIXED CONSTRUCTION
SPRINKLERED
MEZZANINE
MIXED OCCUPANCY
PRIMARY OCCUPANCY:
PROJECT NAME:
PROJECT ADDRESS:
OWNER OR AGENT:
Relevant Code Goes Here
IIB
NFPA 101 - EXISTING
HEALTHCARE
RENOVATE SPS
FAYETTEVILLE VA MEDICAL CENTER
2300 RAMSEY ST FAYETTEVILLE, NC
28301
VA FAYETTEVILLE
LIFE SAFETY LEGEND
0 4 8 16
NORTH
PLAN
NFPA 101 - CHAPTER 43 BUILDING REHABILTATION
43.1.1 - CLASSIFICATION OF REHABILITATION
WORK - RENOVATION
143.4.2 - CAPACITY OF MEANS OF EGRESS. THIS
PROJECT DOES NOT CHANGE OR ALTER EXISTING
PREVIOUSLY APPROVED AS BEING ADEQUATE.
NFPA 101 - CHAPTER 43
BUILDING REHABILITATION
43.1.1 CLASSIFICATION OF REHABILITATION WORK -
MODIFICATION.
43.4.2 CAPACITY OF MEANS OF EGRESS. THIS
PROJECT DOES NOT CHANGE OR ALTER
EXISTING OCCUPANT LOAD OR MEANS OF
EGRESS. THE EGRESS CAPACITY SHALL HAVE
BEEN PREVIOUSLY APPROVED AS BEING
ADEQUATE.
195.67
195.60
196.23
195.02
196.21 196.20
194.49
194.45
194.80
CONC. WALK
CONC. RAMP
196.23
CO
NC
. R
AM
P
CATCH BASIN
EXIST. DRAINAGE MH
RIM = 193.84
I.E. 15" (W): 186.31 I.E. 15" (S): 186.12
4" SAN.
4" SAN.
194.04
194.40
195.10
195.51
194.98
194.72
194.65
195.41
195.33
CONC.
195.26
STAIRS
BO
LL
AR
D
195.02
194.28
FENCE W/ GATE
CONC.
194.58
EXIST. SAN. MH
RIM = 193.84
I.E. 12" (N): 184.74 I.E. 8" (W): 187.28
I.E. 6" (SE): 190.53
GRASS
196.13 194.29
194.64
BLDG. 3 (WAREHOUSE)
BLDG.
BLDG.
ASPHALT
ASPHALT
FFE = 196.19
194.32CONC.
LIMITS OF
CONSTRUCTION
EXISTING DOOR OPENING (TYP.)
GRASS
TRANSF.
ASPHALT
DC1
DC3
DC4
DC5
DC7
DC2
DC8
DC1
DC9
DC10
DC1
DC3 GRASS
GRASS
193.93
DC2
DC6
FFE = 195.35
195.67
195.60
196.23
195.02
196.21 196.20
194.49
194.45
194.80
CONC. RAMP
196.23
CO
NC
. R
AM
P
CATCH BASIN
EXIST. DRAINAGE MH
RIM = 193.84
I.E. 15" (W): 186.31 I.E. 15" (S): 186.12
4" SAN.
4" SAN.
195.10
195.51
194.98
194.72
194.65
FFE = 195.35
195.41
195.33
CONC.
195.26
STAIRS
BO
LL
AR
D
195.02
194.28
.4
FENCE W/ GATE
CONC.
194.58
EXIST. SAN. MH
RIM = 193.84
I.E. 12" (N): 184.74 I.E. 8" (W): 187.28
I.E. 6" (SE): 190.53
196.13 194.29
194.64
BLDG. 3 (WAREHOUSE)
BLDG.
BLDG.
ASPHALT
195.34
FFE = 196.19
8'
LIMITS OF
CONSTRUCTION
6.
3'
(N
EW
O
PE
NI
NG
6.
3'
(N
EW
O
PE
NI
NG
EXISTING DOOR OPENING (TYP.)
5.6'
3.7'
194.31
6.9'
GRASS
.5
TRANSF.
0.
7'
0.
5%
S
LO
PE
AW
AY
195.32
194.00
0.5% SLOPE AWAY
196.18
196.16
194.89
194.50
ASPHALT
195.23
6.
0'
GRASS
193.48
193.83
SL
O
PE
AW
AY
5.0'
193.93
RAISED TABLETOP
CROSSING
C2 C5
C3 C6
C9
C7
C10
C8
C1
193.78
C12
.0
52.4'
195.32
6.6'
C14
C13
C3
C2
16.3'
1.2'
1.2'
C11
C4
1151 Kildaire Farm Rd.
Suite 120 Raleigh, NC 27511 www.acg-pa.com (919)858-7420
108 Benton Lodge Road Suite B Summerville, SC 29485 www.cemsengineering.com (843)875-3637Project Mgr: John Foley (APOGEE)
Joint Venture An Alliance for Success
Revisions: Date
Drawing Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
CONSULTANTS:
# KEY NOTES:
19-112
U.S. Department of Veterans Affairs# © COPYRIGHT Apogee - CEMS JV, LLC
N
KEY PLAN
SCALE: NO SCALE
BUILDING 1
SCOPE OF WORK AREA OF WORK
NC License #: C-1848
Fayetteville VA Medical Center 2300 Ramsey St Fayetteville, NC 28301
Renovate SPS
SEPTEMBER 3, 2021
565-19-102
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
ACG Project Number Office of
Construction and Facilities Management Approved: Project Director
Project Title
Date Checked Drawn
SCALE: 1" = 10'-0"1 EXISTING CONDITIONS / SITE DEMOLITION PLAN
SCALE: 1" = 10'-0"
SITE PLAN
GRAPHIC SCALE
10'
SCALE: 1" = 10'
0 10' 20'
GRAPHIC SCALE
NORTH
EXISTING CONDITIONS / DEMOLITION
AND SITE PLANS
EXISTING CONDITIONS / DEMOLITION LEGEND
BUILDING OUTLINE
CONCRETE PAVEMENT
ASPHALT PAVEMENT
CURB AND GUTTER
CONCRETE PAVEMENT
VENT
TREE
SANITARY CLEANOUT
WATER VALVE
SANITARY MANHOLE
ASPHALT PAVEMENT
CONC.
ABBREVIATIONS:
CONCRETE
S/W SIDEWALK
TRANSF. TRANSFORMER
BLDG. BUILDING
LIMITS OF CONSTRUCTION
TO BE REMOVED
SITE LEGEND
EXISTING NEW
BUILDING OUTLINE
CONCRETE PAVEMENT
ASPHALT PAVEMENT
GUTTER
CONCRETE PAVEMENT OR SLAB
VENT
TREE
SANITARY CLEANOUT
WATER VALVE
SANITARY MANHOLE
ASPHALT PAVEMENT
LIMITS OF CONSTRUCTION
195.60 SPOT ELEVATION
FFE FINISH FLOOR ELEVATION
EXIST. EXISTING
SAN. SANITARY
MH MANHOLE
I.E. INVERT ELEVATION
194.27 SPOT ELEVATION
STORM DRAIN PIPE
195.60
DIRECTION OF SLOPE
CURB AND GUTTER
HANDRAIL (SEE ARCHITECTURAL)
TYP. TYPICAL
WJBSBT
C-101
DC1 REMOVE PORTION OF CONCRETE
CURB
REMOVE PORTION OF CONCRETE
GUTTER
REMOVE GRASS
REMOVE FENCE WITH GATE
REMOVE CONCRETE
REMOVE CONCRETE WALK
REMOVE ASPHALT PAVEMENT
REMOVE LADDER AND RELOCATE
PER ARCHITECTURAL
REMOVE CONCRETE WALK AND
HANDRAILS
CONTRACTOR TO ADJUST SAN. MH
RIM AND WATER VALVE RIM TO
MATCH FINISHED PAVEMENT GRADE
SEE STRUCTURAL FOR CANOPY
COLUMN AND FOUNDATION (TYP.)
4" PVC STORM DRAIN PIPE
(TYP. OF 2)
CONTRACTOR TO ADJUST TIE-IN OF
NEW RAMP TO MATCH EXISTING
PAVEMENT GRADE AT SPECIFIED
LOCATION
CONCRETE GUTTER (TYP.)
HANDRAIL, TYP.
(SEE ARCHITECTURAL)
20 SF OF CONCRETE PAVEMENT
(SEE DETAIL 5/C-102)
SLOPED 4" CONCRETE SLAB ON
GRADE
(SEE STRUCTURAL)
NITROGEN TANK STORAGE AREA
(SEE ARCHITECTURAL AND
STRUCTURAL)
BOLLARD, TYP. OF 2
(SEE DETAIL 7/C-102)
CONCRETE CURB AND GUTTER,
TYP.
(SEE DETAIL 6/C-102)
CONCRETE RAISED TABLETOP
CROSSING
(SEE DETAIL SHEET 1/C-103)
21 SF OF SOD
CHEVRON PAVEMENT MARKING,
TYP. OF 2
(SEE DETAIL SHEET 2/C-103)
CONCRETE SIDEWALK
(SEE DETAIL 1/C-102)
DC2
DC3
DC4
DC5
DC6
DC7
DC8
DC9
DC10
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C11
WV WATER VALVE
W/ WITH
GRASS AREA
BOLLARD
SOD AREA
STORM DRAIN MANHOLE
STORM DRAIN MANHOLE
BOLLARD
C12
C13
CENTERLINE
C14
1151 Kildaire Farm Rd.
Suite 120 Raleigh, NC 27511 www.acg-pa.com (919)858-7420
108 Benton Lodge Road Suite B Summerville, SC 29485 www.cemsengineering.com (843)875-3637Project Mgr: John Foley (APOGEE)
Joint Venture An Alliance for Success
Revisions: Date
Drawing Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
CONSULTANTS: 19-112
U.S. Department of Veterans Affairs# © COPYRIGHT Apogee - CEMS JV, LLC NC License #: C-1848
Fayetteville VA Medical Center 2300 Ramsey St Fayetteville, NC 28301
Renovate SPS
SEPTEMBER 3, 2021
565-19-102
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
ACG Project Number Office of
Construction and Facilities Management Approved: Project Director
Project Title
Date Checked Drawn
LEGEND, ABBREVIATIONS
AND DETAILS
FINISH GRADE
COMPACTED EARTH
1"
CONCRETE WALK
SLOPE
1% MAXIMUM
VARIES (SEE PLANS)
6' CONTRACTION JOINTS
6x6-W2.1xW2.1 WWR
X X X XXXX X
SEE PLANS
XX4"
WIDTH VARIES
50' MAX. SPACING BETWEEN EXPANSION JOINTS
1/4" EXP. JT.
S E
E P
LA
N
S
TOOLED EDGES
NOTES
1. ALL SIDEWALKS SHALL BE 4" THICK.
2. CONTRACTION JOINTS SHALL BE SPACED AT
6'-0"
3. SIDEWALKS TO LIGHT BROOM FINISH
4. ALL JOINTS AND EDGES TO BE TOOLED.
5. SIDEWALKS TO BRUSHED AND TOOLED.
6. CONTRACTION JOINTS SHALL BE 1" DEEP AND
EDGED WITH 1/8" RADIUS.
7. EXPANSION MATERIAL 1/2" THICK SHALL BE
REQUIRED WHERE SIDEWALK ABUTS
CONCRETE STRUCTURE.
STANDARD JOINT LAYOUT FOR CONCRETE SIDEWALKS
SCALE: NOT TO SCALE
TYPICAL SIDEWALK SECTION
SCALE: NOT TO SCALE
SIDEWALK DETAIL
SCALE: NOT TO SCALE1 2
CONCRETE PAVEMENT DETAIL
NEW CONCRETE ELEVATED WALKWAY EXISTING ASPHALT
PAVEMENT SECTION
ASPHALT TO CONCRETE SECTION
PREFORMED
NON-EXTRUDING
JOINT FILLER JOINT SEAL
(SEE NOTE)
4" ± 116"
4" R
NOTE:
1. THE PREFORMED JOINT FILLER SHALL EXTEND TO A DEPTH EQUAL TO THE THINNEST THICKENED EDGE. JOINT
SEALANT SHALL MEET ASTM C 920, TYPE S OR M, GRADE NS, CLASS 25, USE NT. AND AS REQUIRED BY UFC 3-250-01FA.
6" DENSE-GRADED
AGGREGATE BASE
4" - 16" THICK CONCRETE
PAVEMENT PORTLAND CEMENT
(4500 PSI @ 28 DAYS)
12" COMPACTED SUBGRADE
PER EARTHWORK
SPECIFICATION
(95% OF MAXIMUM DRY
DENSITY ASTM D-1557)NOTES
JOINTS IN CONCRETE PAVEMENTS SHOULD BE WATERTIGHT TO
PREVENT PONDING OF WATER WITHIN THE SUB-BASE STONE. THE
SUBGRADE SURFACE SHOULD BE SLOPED TO PROVIDE POSITIVE
DRAINAGE PRIOR TO PLACEMENT OF THE STONE BASE MATERIALS.
WJBSBT
C-102
NOTES:
1. ALL CONCRETE SHALL BE MIN. 3500 PSI.
2. GUTTER SHALL PITCH IN DIRECTION OF DRAINAGE FLOW.
3. ADJUST GUTTER SLOPE AT ADA RAMPS TO BE LESS THAN 5%.
4. CURB AND GUTTER TO BE CONSTRUCTED IN 10 FOOT LENGTHS.
5. 1/2 INCH EXPANSION JOINTS SHALL BE PROVIDED AT INTERVALS NOT TO
EXCEED 50 FEET AT THE ENDS AND MID-POINT OF RETURNS AND AT ANY
POINT WHERE THE NEW CURB AND GUTTER ABUTS OTHER CONCRETE
STRUCTURES & CONCRETE PAVEMENTS.
6. 5 FOOT LONG TRANSITIONS SHALL BE PROVIDED BETWEEN NORMAL
GUTTER AND PITCHED GUTTER UNLESS OTHERWISE NOTED.
6"
.5" 12"
1"R
1.25"R
2'-0"
1"R
6.5"
1"R
6 CONCRETE CURB & GUTTER
SCALE: NOT TO SCALE
SCALE: NOT TO SCALE
SCALE: NOT TO SCALE
7 PIPE BOLLARD DETAIL
SCALE: NOT TO SCALE
2" DOMED CONC.
ROUND TOP
SYMMETRICALLY
CONC.
ENCASEMENT
CONC. SLAB ON
COMPACTED
SUBGRADE
1"
8"
4' -3
4'
-0
2'-0"
(MIN.)
3"
8" DIA. SCHEDULE 80
STEEL PIPE, GRIND
SMOOTH, FILL WITH
CONC. AND PAINT
SAFETY YELLOW
1151 Kildaire Farm Rd.
Suite 120 Raleigh, NC 27511 www.acg-pa.com (919)858-7420
108 Benton Lodge Road Suite B Summerville, SC 29485 www.cemsengineering.com (843)875-3637Project Mgr: John Foley (APOGEE)
Joint Venture An Alliance for Success
Revisions: Date
Drawing Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
CONSULTANTS: 19-112
U.S. Department of Veterans Affairs# © COPYRIGHT Apogee - CEMS JV, LLC NC License #: C-1848
Fayetteville VA Medical Center 2300 Ramsey St Fayetteville, NC 28301
Renovate SPS
SEPTEMBER 3, 2021
565-19-102
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
ACG Project Number Office of
Construction and Facilities Management Approved: Project Director
Project Title
Date Checked Drawn
RAISED TABLETOP CROSSING AND
PAVEMENT MARKING DETAILS
TRAFFIC
FLOW
10' 8' 11.5'1.
3'
0.
7'
EXISTING CURB
& GUTTER
DRIVING PROFILE
EXISTING ASPHALT WIDTH
TYPICAL SECTION AT CROSSING CENTERLINE
RPM'S
EXISTING CURB
& GUTTER
WHITE MARKINGS CENTERED
IN DRIVE LANE WIDTH
CONCRETE RAISED TABLETOP CROSSING DETAIL
SCALE: NOT TO SCALE1
PLAN VIEW
4" PVC STORM PIPE
4" PVC STORM PIPE
11.5'
8' CONCRETE
RAISED CROSSING10'
EXISTING CURB
& GUTTER
PAVEMENT CENTER LINE
8' CONCRETE
RAISED CROSSING
TEMPORARY 6" WHITE
SEE NOTE
NOTE:
1. WHITE CHEVRON PAVEMENT
MARKINGS SHALL BE CENTERED
WITHIN TRAFFIC LANE UNLESS
OTHERWISE NOTED.
TRAFFIC
FLOW
4' -2
4' -2
8' (SEE NOTE 1)
2' -1
2'
-1
1 1/2" 1 1/2"
8" 8"
8" 8"
12" WHITE
12" WHITE
EDGE OF RAISED HUMP
RPM'S
NOTE:
1. PERMANENT PAVEMENT MARKINGS SHALL BE ALKYD
THERMOPLASTIC WITH GLASS BEADS OR REFLECTIVE HEAT
TRANSFER TAPE. CONTRACTOR TO SUBMIT SPECIFICATIONS TO VA
FOR APPROVAL PRIOR TO INSTALLATION.
2. IF PERMANENT PAVEMENT MARKINGS ARE NOT INSTALLED PRIOR
TO MOUNDED CONCRETE BEING OPEN TO TRAFFIC, THEN THE
CONTRACTOR SHALL PROVIDE TEMPORARY 6" WHITE STRIPING ON
THE HUMP AS SHOWN. UPON COMPLETION OF PERMANENT
MARKINGS, ALL TEMPORARY MARKINGS SHALL BE REMOVED BY
THE CONTRACTOR. PERMANENT PAVEMENT MARKINGS SHALL BE
INSTALLED WITHIN A MAXIMUM OF SEVEN (7) DAYS AFTER
CONCRETE MOUND INSTALLATION.
CHEVRON PAVEMENT MARKING FOR RAISED CROSSING DETAIL
SCALE: NOT TO SCALE2
TRAFFIC
FLOW
8'
1 1/2"
8" 8"
8" 8"
12" WHITE
12" WHITE
WHITE CHEVRON PAVEMENT MARKING ENLARGED DETAIL
SCALE: NOT TO SCALE3
RPM'S
2' -1
2'
-1
LEADING EDGE OF
RAISED CROSSING
4' -2
2'-8 1/2"2'-9"2'-6 1/2"
76°
4°
104° 1 1/2"
4°
1/
2"
1/ 2"
1' -4
1'
-5
8" 8"
TRAFFIC
FLOW
1' SPACE TO MARKINGS
FROM CENTERLINE
8"
8"
0.
7' 1.
3'
EXISTING SIDEWALK
NEW SIDEWALK
EXISTING SIDEWALK
NEW SIDEWALK
4" PVC STORM PIPE
4" PVC STORM PIPE
WJBSBT
C-103 3 3
6" DENSE-GRADED
AGGREGATE BASE
6" - 16" THICK CONCRETE
PAVEMENT PORTLAND CEMENT
(4500…