DRAWINGS (Arch) Repair Barracks.pdf
PDF 5 MB Posted
- Attached to
- Repair Barracks Bldg S-1115 Camp Casey
- Solicitation number
- W91QVN21R0063
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A-1
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
1ST FLOOR PLANS AND GENERAL NOTES
STAIR-2
LIVING/
LIVING/
SLEEPING
SLEEPING
D15
FEC
SLEEPINGSLEEPING
104 103
UP
VEST
D11
D5
LIVING/ LIVING/
CORRIDOR
SLEEPINGSLEEPING
102 101
LIVING/ LIVING/
D20D21
JAN
SLEEPINGSLEEPINGSLEEPING
LIVING/
LIVING/
SLEEPING
LIVING/ LIVING/
SLEEPINGSLEEPING
LIVING/
LIVING/
SLEEPING
110 111
LIVING/ C H
D18
COUNTER
COUNTER
DD125
CLOSET
VEST
D1
B/B
D6
TOILET
D14
D7
D9
SLOPE
MUD ROOM
D2
S L
O P
E
D8
WW WW
LOBBY
D13
D16
COMM
D19
D17
UP
STAIR-1
FEC
LAUNDRY
D D
D10 W W W W
DDD
SLEEPING
SLEEPING
WWW
SLEEPING
CORRIDOR
LIVING/LIVING/
D D D
W W W
LIVING/
FEC
LIVING/
SLEEPING
STORAGE
STORAGE
D23
D24
D24 D22
LIVING/
SLEEPING
MECH ROOM
LIVING/
SLEEPING
LIVING/
SLEEPING
D24
D22
D24
LIVING/
SLEEPING
STAIR-3
VEST.
UP
D12
D3
D23 D23
D24
D24
D22
LIVING/
SLEEPING
D25 D25
PARTIAL PLAN
SEE TYP. MODULE
MANUFACTURES INDICATED.
PURPOSES ONLY. AND NOT INTENDED TO LIMIT SELECTIONS TO PRODUCTS OF THE
COLORS AND PATTERNS LISTED BY MANUFACTURES ARE FOR BIDDING IDENTIFICATION 1.
ADJACENT AREAS AS DIRECTED BY THE CONTRACTING OFFICER REPRESENTATIVE (COR).
CAUSED BY THIS PROJECT AND SHALL REPAIR THE DAMAGES TO MATCH UP TO
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES MADE TO EXISTING AREAS
FOR APPROVAL.
CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITION AND SUBMITED TO COR
CONDITION. IN THAT CASE, SHOP DRAWINGS SHALL BE PREPARED AT THE SITE BY THE
SOME DETAILS SHOWN ON CONTRACT DRAWINGS MAY NOT COINCIDE WITH THE FIELD
8.
FOR APPROVAL.
CONTRACTOR SHALL SUBMIT MANUFACTURER'S INSTALLATION SHOP DRAWINGS TO COR
OFFICE, DPW. PER DIRECTION FROM THE INSPECTOR IN CHARGE OR COR
SALVAGE OR SERVICEABLE MATERIALS SHALL BE RETURNED TO SUPPLY OR STORAGE
2.
3.
4.
5.
6.
7.
CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER
IF THERE ARE ANY CONFLICTS WITHIN THE CONTRACT DOCUMENT. THE GENERAL
AND DIMENSIONS PRIOR TO COMMENCING ANY CONSTRUCTION OR RENOVATION.
THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFYING ALL EXISTING CONDITION
OF THE LOAD BEARING WALLS TO PREVENT COLLAPSE OF THE STRUCTURE
APPROPRIATE TEMPORARY SUPPORTS SHOULD BE CONSTRUCTED PRIOR TO DEMOLITION
9.
10.
11.
12.
13.
14.
15.
BE AS A PART OF THE CONTRACT DOCUMENT OF THIS PROJECT.
STANDARD DETAIL DRAWINGS FOR O&MA PROJECT, KOREA, DATED OCTOBER 1, 2003 SHALL
NUMBERS ARE FROM TM-5-807-7 AND FEDERAL STANDARD NO. 595b, COLORS.
COLOR OF MATERIALS & PAINTS SHALL BE SELECTED BY USING AGENCY AND COLOR
COMMENCEMENT OF FLOOR TILE WORK.
ALL CONCRETE FLOOR SURFACES SHALL BE LEVELED AND SMOOTHED PRIOR TO
DETAILS AND GET APPROVAL FROM COR. BEFORE FABRICATION AND INSTALLATION.
CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL DOOR/WINDOW
WALL : 2.00 SM. DEG K/W
ROOF : 5.64 SM. DEG K/W
R-VALUE :
ADDITIONAL COST TO THE GOVERNMENT.
EQUIPMENT, ETC), ELECTRICAL, TELEPHONE AND FIRE ALARM SYSTEM WITHOUT
THE INSTALLATION AND/OR REPLACEMENT OF MECHANICAL (PLUMBING, HEATING,
ITEMS, CUT, PATCH AND RESTORE WALLS, FLOORS AND CEILING WHERE REQUIRED FOR
THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVE/REINSTALL ANY OBSTRUCTED
GENERAL NOTES
SPECIFICATION 15181.
ITEMS REQUIRING MAINTENANCE/OPERATION IAW THE SECTION 3.1.14, OMA STD
PROVIDE ACCESS DOORS FOR ALL CONCEALED VALVES, VENTS, CONTROLS AND OTHER
L E G E N D
PARTIAL PLAN
SEE TYP. MODULE
AND MOLD/MILDEW.
PAINTED SHALL BE FREE FROM RUST, DUST, OILS, GREASE, DIRT, CRACKS, DAMAGES
CLEAN ALL SURFACES TO BE PAINTED TO THE PAINTING WORK. ALL SURFACES TO BE
W2
W2 W2
W2
W3W3
TYPW1
SCALE:
1 : 100
1ST FLOOR PLAN
16.
W1 W1
TYPTYP
TYP
TYP
TYP
TYPTYP
TYP
TYP
TYP
TYPTYP
TYP
TYP
TYP
TYP
FD
FD
7,6007,4007,4004,00010,2004,0007,4007,4007,600
63,000
,0
,2
,5
,2
22,40018,20022,400
3,6007,6007,4003,8007,8002,6007,8003,8007,4007,6003,600
4,200
DS
ROOM
W4
ROOM
L1
A-5
A-3
A-5
A-3
A-8
A-4
A-8
A-5
A-4
PIPING WORK
& METAL STUDS WITH NEW FOR MECHANICAL
REPLACE CMU OR GWB INCL. METAL SHAFT
200 THK MET STUD
150 MM METAL STUD WALL
BOARD
ISSUE
EWC
W5
W6
TRENCH COVER (TYP)
REPLACE
REPLACE BULLETIN
AL GRATING (TYP)
REPLACE
CONC STOOP
REPLACE
CONC STOOP
REPLACE
AL GRATING (TYP)
REPLACE
D4
CONC STOOP
REPLACE
IB
IB
V
(TYP)
GRAVEL BED & GRANITE STONE
MULTI PURPOSE
APPLY TC ON NEW 15T GWB
REMOVE EXST AWP &
TC TC
TC
TC
REPAIR BARRACKS S-1115
CAMP CASEYKWON, CH
243525
A-2
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
AND SCOPE OF WORK
2ND - 4TH FLOOR PLANS
SLEEPING
LIVING/
SLEEPING
LIVING/
D30
4TH FL : GAME ROOM
3RD FL : LOUNGE
2ND FL : KITCHEN
FEC
SLEEPING
STAIR-2
D26
DN
UP
LIVING/ LIVING/
SLEEPING
SLEEPING
VEST
D11
407 408 409
SLEEPING
LIVING/ LIVING/
SLEEPING
SLEEPING
LIVING/ LIVING/
410 411
429 329 229
JAN
412 413
SLEEPING
LIVING/
MAKER
REF
ICE
REF
237 337
COMM
D28
D27
DN
LIVING/
SLEEPING
UP
STORAGE
FEC
STAIR-1
D29
D19
CORRIDOR
D18
STORAGE
332232 432
SLEEPING
LIVING/LIVING/
SLEEPING
LIVING/
SLEEPING
417416
FEC
SLEEPING
SLEEPING
SLEEPING
LIVING/
LIVING/
SLEEPING
LIVING/
SLEEPINGSLEEPING
LIVING/
LIVING/
SLEEPING
LIVING/
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
STAIR-3
UP
DN
D31
VEST
D12
SLEEPING
LIVING/
63,000
7,6007,4007,4004,00010,2004,0007,4007,4007,600
,0
,2
,2
3,6007,6007,4007,60010,6007,6007,4007,6003,600
CH PS
W7
W3 W3
TYPW1
SCALE:
1 1 : 100
TYPICAL FLOOR PLAN (2ND-4TH)
W2 W2
TYPW1 TYPW1
D25D25
D24
D24 D22
D23D23 D22
D24
D24
PARTIAL PLAN
SEE TYP. MODULE
PARTIAL PLAN
SEE TYP. MODULE
D23 D22
D24
D24
TYP
TYP
TYPTYPTYPTYP
TYP
TYP
TYP
TYP
TYP
TYP
TYPTYP
,5
REPAIR / MAINTENANCE (K) WORK
DS
DS
L E G E N D
PIPING WORK
& METAL STUDS WITH NEW FOR MECHANICAL
: REPLACE CMU OR GWB INCL. METAL SHAFT
SCOPE OF WORK (ARCHITECTURAL WORK)
A-5
A-4
A-5
A-3
A-5
A-3
A-8 A-4 A-8
FLOORING. PROVIDE LEVELING CONCRETE FOR EXISTING CONCRETE SLAB IF NEEDED.
LOW SPOTS, HIGH SPOTS, PAINTING, AND UNEVEN SURFACE SHALL HAVE BEEN CORRECTED FOR NEW
SHALL BE SMOOTH, TRUE, LEVEL PLANE WITH ALL DEFECTS SUCH AS ROUGH OR SCALING CONCRETE, AS SHOWN ON NEW FLOOR PLAN & INTERIOR FINISH SCHEDULE. THE EXISTING CONCRETE FLOORING
REPLACE DETERIORATED EXISTING FLOOR TILE & RUBBER TILE WITH NEW PVCT INCLUDING VCB & RB
ON DOOR/WINDOW SCHEDULE. (NATURAL COLOR, OAK)
REPLACE DETERIORATED EXISTING WOODEN HEAD, JAM & SILL FOR ALL WINDOWS WITH NEW AS SHOWN
1. FLOOR WORK
2. INTERIOR & EXTERIOR WALL WORK
2.1
2.2
2.3
1.1
1.2
1.3
2.4
2.6
1.4
SHOWN ON FLOOR PLANS AND SECTIONS.
COATS, WATER PROOF MEMBRANE, PLASTERING W/METAL LATH AND WATERPROOF GWB AS
REPLACE DETERIORATED EXISTING GCWT(FULL HEIGHT) WITH NEW INCLUDING CEMENT BOND
1.5
4.1
4.3
4.4
4.5
3.4
4.2
3.2
3.3
4. MISC. WORK
3.1
3. INTERIOR & EXTERIOR CEILING/ROOF WORK
3.5
REPLACE DETERIORATED EXISTING WINDOW HORIZONTAL MINI BLINDS WITH NEW, FIREPROOF TYPE.
ON FLOOR PLANS AND FINISH SCHEDULE.
WATER RESISTANT OR 'X' TYPE) CEILING INCLUDING CEILING SUSPENSION SYSTEM AS SHOWN
REPLACE DETERIORATED EXISTING CEILING WITH NEW GYPSUM WALL BOARD (GWB, NORMAL,
SECTION.
PAINT ON ALL INTERIOR CEILING SURFACES AS SHOWN ON INTERIOR FINISH SCHEDULE AND
FLOOR PLAN AND ELEVATIONS.
PAINT ALL EXISTING EXTERIOR EXPOSED METAL, WOODS, FASCIA AND SOFFIT AS SHOWN ON
FLOOR PLAN AND SECTIONS.
APPLY ACRYLIC FLUID-APPLIED WATERPROOFING COATING ON EXISTING ROOF AS SHOWN ON
SETS AS SHOWN ON NEW FLOOR PLAN AND DOOR SCHEDULE.
REPLACE DETERIORATED EXISTING DOORS AND DOOR FRAMES WITH NEW INCLUDING HARDWARE
AND WINDOW SCHEDULE.
THERMAL BREAKER TYPE WINDOWS INCLUDING GLASS AS SHOWN ON FLOOR PLANS, ELEVATIONS
REPLACE DETERIORATED EXISTING WINDOWS INCLUDING INSECT SCREEN WITH NEW ALUMINUM
AND LOUVER SCHEDULE.
REPLACE DETERIORATED EXISTING ALUMINUM LOUVER WITH NEW AS SHOWN ON FLOOR PLANS
AND INTERIOR FINISH SCHEDULE.
APPLY EPOXY COATING WITH NON SLIP GRITS ON EXISTING FLOORS AS SHOWN ON FLOOR PLAN
PLANS, SECTIONS AND DETAIL DRAWINGS.
NORMAL, WATER RESISTANT OR 'X' TYPE) INCLUDING METAL STUDS AS SHOWN ON FLOOR
REPLACE DETERIORATED EXISTING ALL GWB WALL BOARD WALLS WITH NEW GWB WALL (GWB,
PIPING SYSTEM AS PER FLOOR PLANS. SECTIONS AND DETAIL DRAWING.
GWB PIPE CHASES / METAL COVER INCLUDING ACCESS DOOR IN EACH ROOMS FOR NEW MECHANICAL
REPLACE DETERIORAGED EXISTING PIPE CHASES / PIPE COVER WITH NEW CMU, WATERPROOF TYPE
METAL SUSPENSION SYSTEMS AS SHOWN ON FLOOR PLANS AND INTERIOR FINISH SCHEDULE.
REPLACE DETERIORATED EXISTING CEILING WITH NEW ACOUSTICAL CEILING TILES INCLUDING
RAILS, GURAD RAILS AS SHOWN ON FLOOR PLAN, DETAIL DRAWINGS INTERIOR FINISH SCHEDULE.
PAINT ALL EXISTING INTERIOR WALLS INCLUDING CMU, METAL, CONCRETE SURFACES, STAIRWAY, HAND
2.5
2.7
SHOWN ON FLOOR PLANS AND INTERIOR FINISH SCHEDULE.
REPLACE DETERIORATED EXISTING QUARRY TILE INCLUDING QUARRY TILE BASE WITH NEW AS
DRAWINGS.
ROOM ON 1ST FLOOR FOR MECHANICAL SEWER LINE WORKS AS SHOWN ON FLOOR PLAN AND MECH
REPLACE EXISTING CONCRETE SLAB AT CORRIDOR, EACH BATH ROOMS, TOILET, LAUNDRY AND MUD
REPLACE DETERIORATED EXISTING METAL SHELF WITH MOP RACK WITH NEW IN JANITOR ROOM.
4.6
4.7
4.8
4.9
4.10
4.11
PLANS AND DETAIL DRAWINGS.
REPLACE DETERIORATED EXISTING ALL TOILET ACCESSORIES WITH NEW AS SHOWN ON FLOOR
ON FLOOR PLANS AND DETAIL DRAWING.
REPLACE DETERIORATED EXISTING FIRE EXTINGUISHERS CABINETS(FEC) WITH NEW AS SHOWN
UPPER CABINET AS SHOWN ON FLOOR PLAN, ELEVATION AND DETAIL DRAWINGS.
REPLACE DETERIORATED EXISTING KITCHENETTE WITH NEW INCLUDING BASE CABINET AND
PLAN, ELEVATIONS AND SIGNAGE SCHEDULE.
REPLACE INTERIOR & EXTERIOR SIGNAGES WITH NEW FOR ALL ROOMS AS SHOWN ON FLOOR
4.12 BED INCLUDING GRANITE CURB AROUND BUILDING AS SHOWN ON FLOOR PLAN AND DETAIL DRAWING.
REPLACE DETERIORATED EXISTING GRAVEL BED AND CONC CURB WITH NEW 100mm DEEP GRAVEL
SHOWN ON FLOOR PLAN AND ENLARGED FLOOR PLAN.
REPLACE DETERIORATED EXISTING ALL ACCESS DOORS ON WALL & CEILING WITH NEW AS
PLAN & ELEVATION.
REPLACE DETERIORATED EXISTING RAIN GUTTER WITH NEW AT CANOPIES AS SHOWN ON FLOOR 3.6
MEMBRANE, MORTAR BED AS SHOWN ON FLOOR PLANS, SECTION AND DETAILS DRAWINGS.
REPLACE DETERIORATED EXISTING CMT WITH NEW CFT INCL. CEMENT BOND COAT, WATERPROOF
@ 2ND FL ONLY
COUNTER & CABINET
PLANS, ELEVATIONS AND INTERIOR FINISH SCHEDULE.
APPLY TEXTURE COATING WITH PLASTERING AT DRESSING ROOM AND CLOSET AS SHOWN ON FLOOR
INTERIOR FINISH SCHEDULE.
NEW GWB IN MULTI PURPOSE RM, KITCHEN, LOUNGE AND GAME RM AS SHOWN ON FLOOR PLAN AND
REMOVE DETERIORATED EXISTING AWP (ACOUSTICAL WALL PANELS) AND APPLY TEXTURE COAT ON
NEW 15T GWB
& APPLY TC ON
REMOVE EXST AWP
DRAWINGS AND PICTURES.
HOUSE & PAVILION) OF EXTERIOR SURFACE OF THE BUILDING AS SHOWN ON FLOOR PLAN, DETAIL
STAIRWELS, HAND RAILS, GURAD RAILS AND OTHER COMPONENTS (BICYCLE RACK, TRASH BIN, PUMP
PAINT ALL EXISTING EXTERIOR WALLS INCLUDING EIFS, CMU, METAL, WOODS, CONCRETE SURFACES, REPAIR BARRACKS S-1115
A-3
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
CMU & INSUL
1ST FL
2ND FL
3RD FL
4TH FL
ROOF BEAM
TOP OF
FIXED & INSULATION
33.4
33.4
GUARD
BUILDING IDENTIFICATION
SEE SIGNAGE SCHEDULE
BOARD
BUILDING IDENTIFICATION
,4
,7
,3
,3
,0
SEALANT
ROOF SCUTTLE (TYP)
PAINT ON EXST
PAINT ON EXST
PAINT (TYP)
PAINT ON EXST
CHIMNEY
SCALE:
1 1 : 100
FRONT ELEVATION
SCALE:
1 : 100
SIDE ELEVATION
33.4
PROTECTED METAL ROOF
WATERPROOFING ON EXISTING
APPLY ACRYLIC FLUID-APPLIED
CONC STOOP
REFINISH EXST
EXST EIFS
PAINT ON
ACRYLIC WATERPROOFING
ON EXISTING PROTECTED
METAL ROOF (TYP)
CONC FASCIA (TYP)
CONTROL JOINT (TYP)
AL BLAST WINDOW (TYP)
EXST MET CANOPY
PAINT ON
(TYP)
STL BLST DOOR
BLAST WINDOW (TYP)
AL SLIDING
REPLACE
CONC STOOP
REPLACE
DOOR
AL BLAST
REPLACE
BULLETIN
REPLACE
SST SPLASH
REPLACE
CONC STOOP
REPLACE
CONC STOOP
REPLACE
CONC STOOP
REPLACE
RAIN GUTTER
REPLACE
REPLACE EXISTING ALUMINUM LOUVERS WITH NEW AS SHOWN ON FLOOR PLANS AND DETAIL DRAWINGS.
REPAIR / MAINTENANCE (K) WORK
SCOPE OF WORK (ARCHITECTURAL WORK)
4. MISC. WORK
PLAN AND DETAIL DRAWING.
REPLACE DETERIORATED EXISTING AL GRATING COVERS WITH NEW FOR EACH VEST AS SHOWN ON FLOOR
4.13
4.14
4.15
4.16
4.17
4.18
4.19
4.20
4.21
4.22
DRESSING ROOM AS SHOWN ON NEW FLOOR PLANS AND DETAIL DRAWING.
REPLACE DETERIORATED EXISTING VANITY CABINETS INCLUDING WALL HUNG CABINET WITH NEW IN ALL
4.23
STORAGE BIN AS SHOWN ON FLOOR PLANS AND ELEVATIONS.
REPLACE DETERIORATED EXISTING 18THK PLYWOOD SHELVES INCLUDING PLASTIC LAMINATE AT EACH 4.24
REPLACE DETERIORATED EXISTING CONCRETE STOOPS WITH NEW AS SHOWN ON FLOOR PLAN.
SHOWN ON FLOOR PLAN, DETAIL DRAWING AND SIGNAGE SCHEDULE.
REPLACE DETERIORATED EXISTING EXT./INT. BULLETIN BOARDS, CARD HOLDER AND FLEXI INFO WITH NEW AS
4.25
ELEVATIONS AND SCOPE OF WORK
SST SPLASH GUARD
REPLACE
FLOOR PLAN AND DETAIL DRAWING.
REPLACE DETERIORATED EXISTING COUNTER TOP AND SST SHELVES WITH NEW AT LAUNDRY AS SHOWN ON
PLAN AND DETAILS.
REPLACE WOODEN SHELF, SST ROD AND DRAWER CABINET WITH NEW IN EACH CLOSET AS SHOWN ON FLOOR
EXTERIOR ELEVATIONS.
REPLACE DETERIORATED EXISTING SST SPLASH GUARDS WITH NEW AS SHOWN ON FLOOR PLANS AND
AND STAIRWELL AS SHOWN ON FLOOR PLANS.
REPLACE DETERIORATED EXISTING FIRE RATED ACCESS DOORS (1-1/2 HRS) WITH NEW AT LAUNDRY RM
KITCHEN, LOUNGE AND GAME ROOM WITH NEW AS SHOWN ON FLOOR PLANS, ELEVATIONS AND DETAIL DRAWINGS.
REPLACE EXISTING DETERIORATED WOODEN CHAIR RAILS AND WOODEN HANGER RAILS AT EACH BED ROOM, COVER AT MUD ROOM AS SHOWN ON FLOOR PLAN AND DETAIL DRAWING.
REPLACE DETERIORATED EXISTING TRENCH COVERS, HOOKS AND HOSE BIB WITH NEW, AND CHECKED METAL
DETAIL DRAWING.
REPLACE DETERIORATED EXISTING IRON BOARD CABINET WITH NEW AS SHOWN ON FLOOR PLAN PICTURES AND
REPAIR BARRACKS S-1115
A-4
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
33.4
33.4
33.4
3RD FL
2ND FL
TOP OF
ROOF BEAM
4TH FL
1ST FL
,4
,7
,3
,3
,0
PAINT (TYP)
EXST CHIMNEY
PAINT ON
SCALE:
1 : 100
SIDE ELEVATION
SCALE:
1 : 100
REAR ELEVATION
APPLY ACRYLIC FLUID-APPLIED WATERPROOFING
ON EXISTING PROTECTED METAL ROOF
CONTROL JOINT(TYP)
CMU & INSUL
SEALANT
PAINT (TYP)
PROTECTED METAL ROOF
WATERPROOFING ON EXISTING
APPLY ACRYLIC FLUID-APPLIED
PAINT (TYP)
AL BLAST WINDOW(TYP)
EXST MET CANOPY
PAINT ON
EXST COLUMNS
PAINT ON
(TYP)
AL BLAST WINDOW
REPLACE
CONC STOOP
REPLACE
CONC STOOP
REPLACE
CONC STOOP
REPLACE
FIXED & INSULATION
REPLACE
CONC STOOP
REPLACE
RAIN GUTTER
REPLACE
CONC STOOP
REPLACE
ELEVATIONS AND PICTURES
(TYP)
MET SURFACE
PAINT ON
BYCYCLE RACK
PAINT ON EXST
SCALE:
PICTURES
N/A
APPLY ACRYLIC FLUID-APPLIED WATERPROOFING
& DOORS (TYP)
EXST EIFS WALL
PAINT ON
EIFS (TYP)
PAINT EXST
ON EXISTING PROTECTED METAL ROOF (TYP)
REPAIR BARRACKS S-1115
A-5
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
GENERAL SECTIONS
ROOF BEAM
1ST FL
3RD FL
2ND FL
4TH FL
SLEEPING
LIVING/ LIVING/
SLEEPING
TOP OF
33.4
STORAGE STORAGE
STORAGE STORAGE
STORAGE STORAGE
STORAGE STORAGE
33.4
VEST
KITCHEN
LOUNGE
GAME ROOM
CORRLOBBY
STORAGE
MECH ROOM
CORRIDOR
CORRIDOR
STORAGE
STORAGE
CORRIDOR STORAGE
LIVING/
SLEEPING
33.4
CORR
CORR
CORR
CORR
LIVING/
SLEEPING
33.4
1ST FL
2ND FL
3RD FL
4TH FL
ROOF BEAM
TOP OF
,4
,7
,3
,3
,0
,4
,7
,3
,3
,0
(TYP)
CHASE WALL
FRAMES (TYP)
EXST WOODEN
VARNISH ON
SCALE: 1 : 100
GENERAL SECTION-1
SCALE: 1 : 100
GENERAL SECTION-2
SCALE: 1 : 100
GENERAL SECTION-3
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/ LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
SLEEPING
LIVING/
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
2 3
W/METAL FRAME (TYP)
PROTECTED METAL COVERING
PROTECTED METAL ROOF (TYP)
WATERPROOFING ON EXISTING
APPLY ACRYLIC FLUID-APPLIED
PROTECTED METAL ROOF (TYP)
WATERPROOFING ON EXISTING
APPLY ACRYLIC FLUID-APPLIED
PROTECTED METAL ROOF (TYP)
WATERPROOFING ON EXISTING
APPLY ACRYLIC FLUID-APPLIED
EXST CHIMNEY
PAINT ON
BLAST WINDOW(TYP)
AL SLIDING
REPLACE
JAMB, SILL (TYP)
WOODEN HEAD,
REPLACE
AL FLASHING (TYP)
REPLACE
REPAIR BARRACKS S-1115
A-6
ARCHITECTURAL
1A
89200
1B
VCB
PVCT PVCT
VCB
1D
VCB
GWB CEILING
C L
G
H
T
BATHROOM
ON 12 THK GWB CEILING
BATHROOM
ON 12 THK
GWB CEILING
ON 12 THK
BED ROOMBED ROOM
W/ STL FRAME
C
T
WD DOOR
GWB CEILING
ON 12 THK
C
T
CORRIDOR
ACST CEILING
1E
1F
PVCT
VCB
BATH ROOM
C
T
ON 12 THK
GWB CEILING
SLEEPING
LIVING/
C
T
GWB CEILING
ON 12 THK
MECH
SEE MECH DWG
FOR CHASE
(TYP)
PENETRATIONS
,3
,0
,6
,2
0 2 ,4
,3
,0
,6
,1
1G
PVCT
VCB
90 STL CHANNEL
GWB CLG ON
@ 406 O C
ACST CEILING
VEST
12 THK
(SHOWER AREA)
GWB CEILING
C
T
BATHROOM
ON 12 THK
GWB CEILING
(SHOWER AREA)
MEMBRANE ON
BATHROOM
ON 12 THK
C
T
SEE MECH DWG
FOR CHASE
PENETRATIONS
(TYP)
ON 15 DEPRESSED
ON CONC SLAB
(1ST FL ONLY)
,4
,3
,1
,1
,6
,0
,3
,0
PAINT
PAINT
PAINT ON
EXST CMU
PAINT
PAINT ON
EXST CMU
PVCT
PAINT ON
EXST CMU
PAINT ON
EXST CMU
PAINT ON
EXST CMU
PAINT
PAINT
TC
TC
TC ON
TC
SCALE: 1 : 20
INTERIOR WALL SECTIONS-1
(2ND THRU 4TH FL ONLY)
1ST FLOOR PLAN
2ND-4TH FLOOR PLAN
KEY PLAN
1E 1N 1P 1Q
1F 1H 1J
1G1B 1M 1L
1K 1D
1A
1R
CQ ROOM
150200
PLYWOOD
ON 19 THK
AL SLIDING
WINDOW
1C
1C1S
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
GCWT ON
CEMENT BOND COAT
ON WATERPROOFING
MEMBRANE ON
FT ON CEMENT BOND COAT
ON WATERPROOFING MEMBRANE
ON MORTAR BED ON EXIST
CONC SLAB (TYP)
FT ON CEMENT BOND COAT
ON WATERPROOFING MEMBRANE
ON MORTAR BED ON EXIST
CONC SLAB (TYP)
GCWT ON
CEMENT BOND COAT
ON WATERPROOFING
MEMBRANE ON
PLASTERING W/MET
WALL (TYP)
QT ON MORTAR BED
ON MORTAR BED ON EXIST
OR FT ON CEMENT BOND COAT
FT ON CEMENT BOND COAT
ON WATERPROOFING MEMBRANE
ON MORTAR BED ON EXIST
CONC SLAB
CONC SLAB
GCWT ON
CEMENT BOND COAT
ON WATER PROOFING
PLASTERING W/MET LATH ON
SSM
QTB
INTERIOR WALL SECTIONS-1
LATH ON EXST CMU
LATH ON 6THK CEMENT
RT
VCB
PVCT
VCB
ACST CEILING
C
T
ACST CEILING
150 200
PLASTIC
PLYWOOD
ON 19 THK
LAMINATED
ISSUE ROOM
AL SLIDING
WINDOW
C
T
,4
,3
,0
,7
,1
,1
PAINT ON
EXST CMU
CMU
PAINT ON
@400 O.C (TYP)
ON 50T MET STUD
PAINT ON 15T GWB
@400 O.C (TYP)
ON 50T MET STUD
PAINT ON 15T GWB
PLASTERING W/METAL
BOARD ON SHAFT WALL (TYP)
"X" GWB W/STEEL STUD
OR APPROVED EQUAL)
(2-LAYER 12THK TYPE
SHAFT WALL,UL-U497
"X" GWB & 25THK TYPE
[GA FILE NO.WP7080]
SHAFT WALL
6 THK CEMENT BOARD ON
"X" GWB W/STEEL STUD
OR APPROVED EQUAL)
(2-LAYER 12THK TYPE
SHAFT WALL,UL-U497
"X" GWB & 25THK TYPE
[GA FILE NO.WP7080]
ROOM
MULTI PURPOSE
REPAIR BARRACKS S-1115
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
A-7
ON GWB CEILING
C
T
C
T
200 STL STUD
1H
VCB
GWB CEILING
GCWT ON CEMENT
ON 12 THK
TOILET
12 THK GWB
ON FURRING
LOBBY
RT
STAIR-1
C
T
SLEEINGC
T
C
T
1K
VCB
PVCT PVCT
VCB
GWB CEILING
ON 12 THK
LAUNDRY LAUNDRY
(NIC)
DRYER
DUCT
SEE MECH DWG
ON GWB CEILING
@ EACH STUD
90 STL CHANNEL
90 STL CHANNEL
BRACE @ EACH STUD
GWB CEILING
LIVING/ DRESSING
ON 12 THK
CEMENT BOARD ON
C
T
@ 300 O C (MAX)
,4
,3
,7
,3
,4
,3
,4
,6
,2
,4
(SHOWER AREA)
C
T
PVCT
VCB
SLEEPING
LIVING/
12 THK GWB
ON 22 FURRING
@ 400 O C
C
T
C
T
1L
CURTAIN
SHOWER
1M
1N
VCT
BATHROOM
BATHROOM
PAINT ON
GWB CEILING
12 THK
ACST CEILING
GWB
LOBBY
VCB
RT
STAIR-1
C
T
1R
12 THK
GWB CEILING
TC ON
CMU
VCB
ACST CEILING
CORRIDOR
C
T
C
T
PENETRATIONS
FOR CHASE
SEE MECH DWG
(TYP)
GWB CEILING
DRESSING
PVCT
VCB
(2ND THRU 4TH
FL ONLY)
(2ND THRU 4TH
KITCHEN
GWB CEILING
VCB
PVCT
C
T
ACST CEILING
FIXED
CORRIDOR
STL WINDOW
C
T
,6
,3
,4
,4
,7
,0
,3
,4
,4
LAUNDRY
1Q
90 STL CHANNEL
BRACE @ EACH STUD
1P
,2
RB
PAINT
PAINT ON
EXST CMU
PVCT
PAINT
PAINT ON
EXST CMU PAINT ON
EXST CMU
PAINT ON
EXST CMU
PAINT ON 12THK
TC ON
PVCT
TC ON
PAINT
TC
TC ON
TC
@ 400 OC
INTERIOR WALL SECTIONS-2
SCALE: 1 : 20
INTERIOR WALL SECTIONS-2
TC ON 12 THK
1S
VCB
PVCT
VCB
ACST CEILING
C
T
ACST CEILING
C
T
,7
,0
,1
,1
,4
,3
PAINT ON
PAINT ON
CQ ROOM
PVCT
15T GWB
FT ON CEMENT BOND COAT
ON MORTAR BED ON EXIST
CONC SLAB (TYP)
GCWT ON
CEMENT BOND COAT
ON WATERPROOFING
MEMBRANE ON
PLASTERING W/MET
LATH ON ON 90 STL STUD
GCWT ON
CEMENT BOND COAT
FT ON CEMENT BOND COAT
ON WATERPROOFING MEMBRANE
ON MORTAR BED ON EXIST
FT ON CEMENT BOND COAT
ON MORTAR BED ON EXIST
FL ONLY) OR
CONC SLAB
CONC SLAB (1ST FL ONLY)
GCWT ON
CEMENT BOND COAT
ON WATERPROOFING
MEMBRANE ON
PLASTERING W/MET
LATH ON CMU
WALL (TYP)
,2
FT ON CEMENT BOND COAT
ON MORTAR BED ON EXIST
CONC SLAB (TYP)
FT ON CEMENT BOND COAT
ON MORTAR BED ON EXIST
CONC SLAB (TYP)
@ 300 O C (MAX)
CEMENT BOND COAT
ON WATERPROOFING
MEMBRANE ON
PLASTERING W/MET
GCWT ON
LATH ON ON 150 STL STUD
FT ON CEMENT BOND COAT
ON MORTAR BED ON EXIST
CONC SLAB (TYP)
MET STUD
GWB W/150T
A-6 A-6 A-6 A-6 A-6
A-6 A-6 A-6
A-6 A-6
1J
BOND COAT ON
W/MET LATH ON
PLASTERING
ON PLASTERING W/MET
@ 300 O C (MAX)
MEMBRANE ON 90T STUD
EXST WD FRAME
VARNISH ON
PAINT ON
TEXTURE COAT ON
TC ON 12 THK
LATH ON WATERPROOFING
ROOM
MULTI PURPOSE
"X" GWB W/STEEL STUD
OR APPROVED EQUAL)
(2-LAYER 12THK TYPE
SHAFT WALL,UL-U497
"X" GWB & 25THK TYPE
[GA FILE NO.WP7080]
EXST CMU
REPAIR BARRACKS S-1115
A-8
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
FCU FCU
LIVING / SLEEPING
TC ON 12mmTHK GWB
ACCESS DOOR
208 x 208
FCU
LIVING / SLEEPING
ACCESS DOOR
TC ON 12mmTHK GWB
208 x 208
TTDTB TTD
MC
MR
LAV
TB
TB
SC/R
TB
SH SH
TB
MR
MC
LAV
TB
TTD
TB
SC/R
SH
TB
MR
MC
LAV
TB
CLOSET
CLOSET
DRESSING
BATHROOM
BATHROOM
DRESSING
CLOSET
CLOSET
BATHROOM
CLOSET
CLOSET
DRESSING
@1ST FLOOR ONLY @1ST FLOOR ONLY
SC/R
CLRCLR CLR
SHDSHD SHD
7,600
2,0002001,2001,0001,2002001,800
4,000
1,6002001,2001,000
,0
,6
7,675
1,0001,0003,8001,000875
,6
,4
4,075
8751,0004001,600
,0
,0
,0
,0
,0
,6
8001,0006501,175
TYPICAL ENLARGED FLOOR PLANS
SCALE:
1 : 25
TYPICAL ENLARGED FLOOR PLAN-1
TC ON 12mmTHK GWB
ON 90 STL STUD (TYP)
LIVING / SLEEPING
PROTECTED METAL COVER
W/METAL FRAME (TYP)
PAINT ON
EXST CMU
PAINT ON
EXST CMU
TC ON 12mmTHK GWB
ON 90 STL STUD (TYP)
PAINT ON
EXST CMU
PAINT ON
EXST CMU
PAINT ON
EXST CMU
PAINT ON
EXST CMU
PAINT ON
EXST CMU
(TYP)
PAINT ON
EXST CMU
(TYP)
ON 90 STL STUD(TYP)ON 90 STL STUD(TYP)
SCALE:
1 : 25
TYPICAL ENLARGED FLOOR PLAN-2
(TYP)
DRAWER CABINET
GCWT ON
CEMENT BOND COAT
ON WATERPROOFING
MEMBRANE ON
PLASTERING W/MET
ON WATERPROOFING
MEMBRANE ON
PLASTERING W/MET
LATH ON 6THK CEMENT
GCWT ON CEMENT BOAND COAT
ON WATERPROOFING
MEMBRANE ON
PLASTERING W/MET
LATH ON 12THK CEMENT
@ 400 O.C (TYP)
BOARD W/ 90MM MET STUD
GCWT ON CEMENT BOAND COAT
BOARD ON SHAFT WALL (TYP) LATH ON 6THK CEMENT
BOARD ON SHAFT WALL (TYP)
PAINT ON EXST WALL PAINT ON EXST WALL
(TYP)
FRAME AND MOLDING
EXST WOODEN
VARNISH ON
TOILET ACCESSORIES ABBREVIATIONS
MR : MIRROR
: MEDICINE CABINETMC
: SHOWER CURTAIN WITH RODSC/R
: SOAP DISPENSER FOR TOILET @ 1ST FLOORSD
: SHOWER HEADSHD
: TOWEL BARTB
: TOILET TISSUE DISPENSER (FULLY RECESSED)TTD
SH : SOAP HOLDER(PORCELAIN,RECESSED TYPE)
A-16
REPAIR BARRACKS S-1115
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
A-9
2ND FL:KITCHEN
JAN.
D.S
D.S
STAIR-1
COMM.
DN
UP
(NIC)(NIC)
REF REF
(NIC)
MAKER
ICE
4TH FL:GAME ROOM
3RD FL:LOUNGE
327VEST.
LOBBY
TOILET CLOSET
D.S
MUD ROOM
STAIR-1
127 128
130 129
HOSE
BIB
SMLD
PTD TTDSD
UP
FINISH
NON-SLIP
(2400x1000)
IRON BOARD
CABINET
F.D
LAUNDRY
COUNTER
COUNTER
F.D
(NIC)
W
(NIC)
W
(NIC)
W
(NIC)
W
(NIC)
W
(NIC)
W
(NIC)
W
(NIC)
D
(NIC)
D
(NIC)
D
(NIC)
D
(NIC)
D
(NIC)
D
(NIC)
D
(NIC)
D
(NIC)
D
(NIC)
D
(NIC)
W
(NIC)
W
(NIC)
W
(NIC)
W
(NIC)
W
(NIC)
W
(NIC)
W
DROP CEILING LINE
COUNTER &
CABINET
@2ND FL
FINISH
NON-SLIP
TOILET ACCESSORIES ABBREVIATIONS
MR : MIRROR
: MEDICINE CABINETMC
: SHOWER CURTAIN WITH RODSC/R
: SOAP DISPENSER FOR TOILET @ 1ST FLOORSD
: SHOWER HEADSHD
: TOWEL BARTB
: TOILET TISSUE DISPENSER (FULLY RECESSED)TTD
SH : SOAP HOLDER(PORCELAIN,RECESSED TYPE)
(NIC)
RANGE
B/B
HOOK
B/B
BAR @ 15 O.C
25x5 THK BEARING
SCALE: 1/50
ENLARGED PLANS-LAUNDRY AREA
SCALE: 1/50
ENLARGED PLANS-KITCHEN & ETC
MECH. PIPING WORK (TYP)
CHASE WALL FOR
ONLY (TYP)
AL GRATING TRENCH COVER
GRATING COVER
COUNTER TABLE(TYP)
ON WALLS AND CEILINGS (TYP)
ALL ACCESS DOORS
W/GRAVEL
GRANITE CURB STONE
SST SHELF (TYP)
SST SHELF (TYP)
SST SPLASH
GUARD
A-16
MECH. PIPING WORK (TYP)
200T MET STUD WALL FOR
RAIL (TYP)
OAK, CHAIR
MECH. PIPING WORK (TYP)
TC ON NEW CMU FOR
L E G E N D
PIPING WORK
: REPLACE CMU WALL WITH NEW FOR MECHANICAL
DOOR (TYP)
FIRE RATED ACCESS
610 X 610, 1-1/2HRS
FIRE RATED ACCESS DOOR NOTES
@ STAIR WAY & LAUNDRY RM
EXPOSED FLANGE, KNURIED KNOB, SELF-CLOSING DOOR
MFG-BABCOCK DAVIS, MODEL NO-BITK2424, UL LISTED
INSULATED FIRE-RATED ACCESS DOOR, 610 X 610, 1-1/2HRS
TC ON GWB WALL
SEE A-9 NOTE (TYP)
FIRE RATED ACCESS DOOR
610 X 610, 1-1/2HRS
FIRE RATED ACCESS DOOR NOTES
ENLARGED FLOOR PLANS AND
ACCESS DOOR :
EPOXY
EPOXY
V
@ 2ND FL ONLY
COUNTER & CABINET
A-17
1&2
MECH. PIPING WORK (TYP)
PAINT ON NEW CMU FOR
W/HANDLES
CHECKED MET COVER
ON 22 MET FURRING
APPLY TC ON 15T GWB
REMOVE EXST AWP
REPAIR BARRACKS S-1115
A-10
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
AS REQUIRED
VERIFY DIMENSION
1A
OPNG
1B
C
T
C
T
@ 1st FLOOR ONLY
ACCESS DOOR
BLIND
C
T
H A
N G
IN
R
IL
VCB
1C
TB
T O
W E
B
R C
T
1D
ON 18 THK PLYWOOD
(SEE ELEC DWG)
LIGHTING FIXTURE
WOOD DOOR
VCB
C
T
C
T
1E
OPNG
L A
V
MR
TB
C
T
1F
L A
V
C
T
MR
MC
LIGHTING
FIXTURE FIXTURE
LIGHTING
,6
,8
,2
,6
,6
,2
,3
,4
,2
,5
,2
,4
,6
,8
,2
,1
,4
,4
,1
,8
,2
PAINT ON CMU
METAL COVER
PAINT ON CMU
HANGING RAIL(TYP)
WOODEN
PAINT ON EXST GWB PAINT ON EXST CMU
WOODEN HANGING RAIL(TYP)
EXST CMU
PAINT ON
HANGING ROD
SHELF W/
CABINET
INTERIOR ELEVATIONS-1
SCALE:
INTERIOR ELEVATIONS-1
@ LIVING/SLEEPING ROOM @ LIVING/SLEEPING ROOM @ DRESSING ROOM
@ DRESSING ROOM
@ DRESSING ROOM @ DRESSING ROOM
TC ON 12mmTHK GWB
ON 90 STL STUD (TYP)
TC ON 12mmTHK GWB
ON 90 STL STUD(TYP)
PLASTIC LAMINATE(PL-1)
WOODEN FRAME
VARNISH ON EXST
TC ON 15mmTHK GWB
ON 90 STL STUD (TYP)
SCALE: 1 : 25
PAINT ON CMU
REPAIR BARRACKS S-1115
A-11
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
EWC WD DOOR STL DR
C
T
OPEN
VCB BULLETIN BOARD
C
T
1A 1C
1D
1B
C
T
,7
,3
,7
,3
1G
C
T
BULLETIN BOARD
C
T
1E 1F
OAK CHAIR RAIL
1H
1J
C
T
C
T
VCB
C
T
OAK CHAIR RAIL
REF
VCB
(NIC)
ICE MAKER
(NIC)
,6
6 3 ,2
,1
,1
,2
,1
,1
5,450 3,600
,6
,4
,5
,6
,5
(NIC)
RANGE (NIC)
1K
C
T RANGE HOOD
(SEE MACH DWG)
BACK SPLASH
REF
,4
,6
1L
C
T
VCB
OAK CHAIR RAIL
,6
,0
EXST CMU
PAINT ON
EXST CMU
PAINT ON PAINT ON
EXST CMU (BEYOND)
EXST CMU
PAINT ON
PAINT STORAGE BIN
PAINT STORAGE BIN
EXST CMU
PAINT ON
PAINT ON EXST CMU EXST CMU
PAINT ON
INTERIOR ELEVATIONS-2
@ LOBBY
@ LOBBY @ LOBBY @ STORAGE @ STORAGE @ KITCHEN
@ KITCHEN@ KITCHEN@ KITCHEN
1A
A-16 1C
ON 18 THK PLYWOOD(TYP)
PLASTIC LAMINATE(PL-1)
SCALE:
INTERIOR ELEVATIONS-2
SCALE: 1 : 50
1B
A-16 A-16
C
T
VCB
M
T
VCB
ON 90 STL STUD
PAINT ON EXST CMU
,7
,2
STL FIXED FIRE RATED GLASS
ON 22 MET FURRING
TC ON 15T GWB
ON 22 MTL FURRING
TC ON 15T GWB
@ MULTI PURPOSE ROOM @ MULTI PURPOSE ROOM
TC ON 15T GWB W/ METAL LATH
ON 22 MET FURRING
TC ON 15T GWB
TC ON EXST CMU
TC ON EXST CMU
GCWT (TYP)GCWT (TYP)
REPAIR BARRACKS S-1115
C
T
M O
P
C K
S
IN
K
1H
MOP RACK
,4
,8
A-12
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
MG
SMLDSD
C
T
P T
D
T T
D
GCWT
SOAP DISPENSER (SD)
MIRROR GLASS (MG)
WATER CLOSET
GCWTLAVATORY
GCWT
WASHER(TYP), GFGI
DRYER(TYP),GFGI
GCWT
COUNTER
WASHER(TYP)
C
T
1B 1D
PTD
OPEN
1E
1C
C
T
C
T
GFGI
SHELF METAL LIGHT DUTY (SMLD)
PAPER TOWEL DISPENSER (PTD)
TOILET TISSUE DISPENSER (TTD)
,4
,5
,4
,4
,4
1A
GCWT
C
T
BRASS HOOK
GCWT
DRAIN BOARD
1F 1G
C
T
FAUCET
SEE MECH DWG
,0
,4
,6
,2
,4
EXST CMU
PAINT ON
EXST CMU
PAINT ON
VCB
INTERIOR ELEVATIONS-3
@ CORRIDOR
@ TOILET @ LAUNDRY @ LAUNDRY
@ LAUNDRY @ MUD ROOM @ MUD ROOM
A-16
A-14
A-13
SCALE:
INTERIOR ELEVATIONS-3
SCALE: 1 : 50
@ JANITOR CLOSET
PAINT ON GWB OR EXST CMU
SST SHELF
REPAIR BARRACKS S-1115
A-13
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
METHODS OF WALL
FASTENING
BOLT &
3-1.5 THK SST SHELF
TOGGLE BOLT OF EXP
BRACKET W/ 2 -6
1.2 THK SST SHELF
NEED CNETER BRKT
/o
SST HOOK
SST MOP HOLDER
@300 O.C
1A 1B 1C
TBSH
TTD
TB
GCWT
C
T
S H
O W
U
R T
D
T O
W
R
S H
O W
A D
T T
D
TRIM
TILE
T O
W
R
T T
D
TTD
TB TB
GCWT
SC/R
GCWT
C
T
S H
O W
U
R T
D
C
T
,5
,9
,9
,3
,3
,5
,3
,8
ITEM QT'Y TOTAL REMARKS
TTD
MC
TB TOWEL BAR
SC
SCR
SHOWER CURTAIN
SHOWER CURTAIN ROD
SEE OMA. STANDARD DRAWING1
RSD
AS PLAN
TOILET ACCESSORIES SCHEDULE FOR EACH BED ROOM
RECESSED MOUNTED
TOILET TISSUE DISPENSER
RECESSED TYPE SOAP HOLDER
SECTION
PLAN-SECTION
SHOWER AREA
3B
3A
SCALE:
1 : 4
MOP RACK DETAIL
SCALE:
1 : 5
RECESSED SOAP HOLDER DETAILS
SCALE:
1 : 20
SHOWER CURB DETAIL
MEDICNE CABINET
450X650 RECESSED MOUNTED
SCALE: 1 : 25
INTERIOR ELEVATIONS @ BATHROOM
BATH ROOM
R=5
12 THK SSM
SEALANT
WATER PROOFING
MEMBRANE
SHOWER AREA
SHOWER CURTAIN
SLOPE SLOPE
CERAMIC FLOOR
TILE
CEMENT MORTAR
BED
SHOWER CURTAIN
W/ROD
FABRIC REINF
WATER PROOFING
MEMBRANE
EXST CONC OR BRICK CURB
SPACERSRETENTION UNIT
COMPRESSION ROD
STEEL
EXST FRAME
SCALE: 1/10
AL. GRATING DETAIL @ VEST
SOAP HOLDER
PORCELAIN
MORTAR FILL
CEMENT
CMU
GCWT ON
CEMENT BOND COAT
ON WATERPROOFING
MEMBRANE ON
LATH
PLASTERING W/METAL
SOAP HOLDER
PORCELAIN
CMU
MORTAR FILL
CEMENT
GCWT ON
CEMENT BOND COAT
ON WATERPROOFING
MEMBRANE ON
LATH
PLASTERING W/METAL
INTERIOR ELEVATIONS-4 AND DETAILS-1
REPAIR BARRACKS S-1115
A-14
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
DETAILS-2
12THK PANEL CONSISTING
OF 6THK. CORK MOUNTED
ON HARDBOARD
L - 50x50x6 MET. CLIP
@600 O.C
ALUMINUM TRIM
EXST CMU
OAK PLUG
40 x 100
OAK RAIL
@600 O.C.
T
F
O O
R
STRIP WITH 2.0 THK
STAINLESS STEEL
@ 500 O.C.
20x90 WOOD
BRASS HOOK
COVER
@ 400mm OC
@ 500 O.C
BRASS HOOK
STRIP WITH 2.0 THK
20x90 WOOD
STAINLESS
STEEL COVER
TOWEL BAR
TOWEL BAR
FLANGE
"A"
"A"
AS SHOWN
SST BRACKET
SST SHELF
OR EXP. AHR. TO
MATCH BRACKET
(OUTSIDE TRIM DIM.)
(OUTSIDE TRIM DIM.)
(INSIDE BOX DIM.)
FIRE EXTINGUISHER CABINET PLAN
L
IN
S
ID
X
D
IM
O
U T S
METAL DOOR
PULL
METAL TRIM
METAL FIRE
EXTINGUISHER CABINET
METAL DOOR PULL
GLASS
(INSIDE BOX DIM.)
WOOD SHIM
(ALL AROUND)
CONC.FILL
IN
S
X
FLOOR FINISH
VCB
LINE
PULL
METAL DOOR
WOOD SHIM
(ALL AROUND)
SIDE)
SCREW (3-PER
A
A
1 : 10
1B
1A
1C
PAINT
ON EXST CMU
PAINT ON
SCALE:
FIRE EXTINGUISHER CABINET
1 : 5SCALE:
1 : 5SCALE:
1 : 5SCALE:
1 : 5SCALE:
SCALE:
2A
ELEVATION
2A
SECTION
HOOK DETAILS
SHELF METAL LIGHT DUTY DETAILS(SMLD)
3A
PLAN
SCALE : 1/5
3B
ELEVATION
SCALE: 1 : 2
3C
WOODEN HANGER RAIL TOWEL BAR DETAIL
ELEVATION SECTION "A-A"
SECTION "A-A"
4430544
114 89
EXST CMU WALL
BULLETIN BOARD @ LOBBY & VEST
2.0 THK SST SHELF
SUPPORT FRAME @ 800 O.C
@ EACH SUPPORT FRAME
FACE OF WALL
SCALE: 1/10
SST SHELF DETAIL @ LAUNDRY
500 400
REPAIR BARRACKS S-1115
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A-15
ARCHITECTURAL
PLYWD W/
18 THK.
1G 1F
1H
FIN.FL.
18 THK. PLYWOOD
MIRROR ON 12 THK PLYWOOD
LIGHT
(SEE ELEC. DWG.)
18 THK. PLYWOOD
LIGHT(SEE ELEC. DWG.)
18 THK. PLY WOOD
6 THK. PLYWOOD
W/ PLASTIC
LAMINATE
MIRROR
ON 12 THK.
PLYWOOD
18 THK.
PLYWOOD
W/ PLASTIC
LAMINATE
PLYWOOD
18 THK.
MIRROR ON 12HK PLYWD
12 THK GWB
SILICONE SEALANT
6 THK. PLYWOOD
25 x 50 WD
ANCHOR BOLT
@450 O.C
6 THK. PLYWD W/
DRAWER STOPPER
20x40 HARD WD.
PLYWOOD
18 THK.
6 THK. PLYWOOD
W/ PLASTIC
18 THK. PLYWD. W/
CABINET DRAWER
T
Y P
HARDWD TRIM
20x20
PROVIDE A FACE PANEL AT EACH END
THE CLOSET DOORS ARE OPEN
DRAWER WIDTH SHALL BE 500 mm.
DRAWERS TO OPEN FULLY WHEN
OF DRAWER UNIT TO ALLOW THE
X NOTE ;
25 x100 HARDWD
25X 50 WD
SPACER WITH
BOLT @600 O.C
50x100 WD
BLOCK
18 THK.
PLYWD WITH
WD. BLOCK & TO
CONC. SLAB W/
AT 450 O.C
18THK. PLYWD
50x100 WD BLOCK
L-75x75x6 STL
CLIP FIXED TO
VCT
EXP. ANCHORS AT 450 O.C
6 THK. PLYWD W/
18 THK. PLYWD
L-75x75x6 STL. CLIP
FIXED TO WD. BLOCK &
HARDWD TRIM
18 PLYWD W/
18 x 18
VCB
1B 1C
FACE OF CMU
GCWT FINISH
CABINET
MEDICINE EXST CMU
PAINT ON
INCL. METAL STUDS
TC ON GWB
W/PLASTIC LAM(PL-2)
PLASTIC LAMINATE(PL-2)
PLASTIC LAM(PL-1)
WITH PLASTIC LAM(PL-2)
WITH PLASIC LAMINATE(PL-2)
PLASTIC LAM(PL-1)
PLASTIC LAM(PL-1)
PLASTIC LAMINATE(PL-2)
18 THK PLYWOOD
13 THK SOLID SURFACE
MATERIAL (SSM-1) OVER
(COUNTERTOP, BACK &
SIDE SPLASH)
MARINE EDGE
18 THK PLYWOOD
13 THK SOLID SURFACE
MATERIAL (SSM-1) OVER
(COUNTERTOP, BACK &
SIDE SPLASH)
18 THK PLYWOOD
13 THK SOLID SURFACE
MATERIAL (SSM-1) OVER
(COUNTERTOP, BACK &
SIDE SPLASH)
18 THK PLYWOOD
13 THK SOLID SURFACE
MATERIAL (SSM-1) OVER
(COUNTERTOP, BACK &
SIDE SPLASH)
W/ PLASTIC LAMINATE(PL-2)
(PL-1)
W/ PL-1
PLASTIC LAM(PL-1)
DETAILS-3
SCALE:
LAMINATE(PL-1)
W/ PLASTIC LAMINATE(PL-2)
LAMINATE(PL-1)
W/ PLASTIC
W/ PLASTIC LAMINATE(PL-1)
VANITY CABINET DETAILS
AS SHOWN
SCALE: 1 : 20
1A
VANITY CABINET PLAN
SCALE: 1 : 10
1B
VANITY CABINET SECTION-1
SCALE: 1 : 10
1C
VANITY CABINET SECTION-2
SCALE: 1 : 5
1D
DETAIL-1
SCALE: 1 : 5
1E
DETAIL-2
SCALE: 1 : 5
1F
DETAIL-3
SCALE: 1 : 5
1G
DETAIL-4
SCALE: 1 : 5
1H
DETAIL-5
1D 1D
1E 1E
1G 1F
(POST FORMING) TYP.
1,250
910340
PLASTIC LAMINATE (PL-1)
HANGING ROD
4 DIA HOLE (TYP)
CLOTHES
25 DIA SST PIPE
-25x25x2
2.5 THK SST
BRACKET
O O
R
HANGING ROD
SST BRACKET
CLOTHES
2.5 THK
25 DIA SST PIPE
-25x25x2 SST BRACKET
POSTFORM
5 50
0 50
PAINT GWB
BOTH SIDES-SHELF & SIDE PANEL
ON 18 THK PLYWD
PLASTIC LAMINATE (PL-1)
ON 18 THK PLYWD
@ 300 O.C
SEE DETAIL
2C
@ 900 OC
@ 900 OC
SCALE: 1/5
SHELF & ROD DETAILS (CLOSET)
100300
2A 2B
2C
@ 900 OC
OR CMU WALL
9 DIA EXP BOLTS
REPAIR BARRACKS S-1115
CAMP CASEYKWON, CH
243525
22x200 WOOD
1.6 THK SST SOCKET
CLOTHES HANGING ROD
25 DIA SST PIPE
PAINT GWB
BOLTS
9 DIA TOGGLE
ï½
1102020
BED.
SCALE:
CONC CURB & GRAVEL BED DETAIL
1 : 10
EXST EIFS AND CMU
PAINT ON
GRANITE CURB
REPLACE
GRAVEL
REPLACE
X
1200150
900150
BAR @ 100 O.C
5x5 THK CROSS
BAR @ 15 O.C
25x5 THK BEARNG
EXISTING FRAME
SCALE:
TRENCH DETAIL @ MUD ROOM
1/10
W/ ABRASIVE GRAIN
EPOXY ON CONC
EPOXY ON CONC
ON 150 MET STUD @ 400 O.C.
ON 12T CEMENT BOARD
ON PLASTERING W/MET LATH
ON WATERPROOFING MEMBRANE
GCWT ON CEMENTBOND COAT
A-16
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
FASTENER
LINE OF WALL
"A"
"A"
PLATE GLASS
MIRROR
METAL FRAMED
RUBBER BACKING
1.2 THK 12x12 SST FRAME
1.2 THK 12x25 GALV STL
PLATE GLASS MIRROR
W/ PIN KNOT SCREWS
BOLTS 2 - PER SIDE
2 - PER SIDE
RUBBER LINER
SCALE:
1 : 10
SCALE:
MIRROR DETAILS
5A
ELEVATION
N/A
5B
SECTION "A"-"A"
SCALE: 1 : 25
DETAILS-4
LIVING / SLEEPING LIVING / SLEEPING
FCUFCU
W/FRAME(IF NEEDED)
METAL COVER
PENETRATION (TYP)
FIRE SEAL @ PIPE
(2-LAYER 12THK TYPE
PIPE CHASE WALL DETAIL @ FCU
CONC. COLUMN
@900
90 STL CHANNEL
GCWT ON
CEMENT MORTAR
METAL LATH
(TYP.)
@400 O.C.
FURRING
ON 22 METAL
CORNER REINFORCEMENT
90 MET. STUD
SCALE:
1 : 10
COLUMN DETAIL @ LAUNDRY
TC ON
MECH. PIPING WORK
GWB CHASE WALL FOR
425425
"X" GWB W/90T MET STUD)
ACCESS DOOR
208 x 208
@1ST FLOOR ONLY
IRON BOARD
COLUMN DETAIL @ MULTI PURPOSE RM
@400 O.C (TYP)
50THK MET STUD
15THK GWB ON
TC ON
15THK GWB
TC ON
REPAIR BARRACKS S-1115
L-75x75x6
EACH ANGLE
BRACING @600 O.C.(MAX.)
L-75x75x6 STEEL
STEEL
& 12 THK PLYWOOD COUNTER
TOP (POST FORMING METHOD)
PLASTIC LAMINATE(PL-1) ON 18 THK
BOLT @
SCALE:
1:5
O O
R
OAK CHAIR RAIL
20 THKx90
@ 600 O.C
1 / 2SCALE:
CHAIR RAIL DETAIL
1 / 10SCALE:
IRON BOARD DETAIL
1.
2.
IRON BOARD NOTE
CUSTOM CLOSET SYSTEM ACCESSORY THAT FOLDS AWAY WHEN NOT IN USE.
3.
5.
SWIVELS UP TO 90 DEGREES FROM MOUNTING POSITION.4.
6.
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
SCALE:
N/A
PICTURES OF IRON BOARD & CABINET
COUNTER SECTION @ LAUNDRY
A-17
ARCHITECTURAL
DETAILS-5
CABINET. THE SIZE OF IRON BOARD & CABINET CAN BE ADJUSTABLE.
APPROX. SIZE IS 406W X 1574H X 138D SURFACE MOUNTED IRON BOARD &
PULLS OUT ON SOFT CLOSE, BALL BEARING SLIDES.
FOLD-DOWN LEGS WITH 900MM HEIGHT-ADJUST FOR LEVELING.
406Wx1574Hx138D
IRON BOARD & CABINET
APPROX SIZE
SURFACE MOUNTED
PAINT ON
12 THK GWB
GCWT
,4
,2
1,050
EACH CORNER
CONTRACTOR SHOULD SUBMIT SHOP DRAWING OF CABINET FOR APPROVAL.
CONTRACTOR SHOULD SUBMIT SHOP DRAWING OF IRON BOARD FOR APPROVAL.
7.
BOLT @
FT
REPAIR BARRACKS S-1115
A-18
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
THK PLYWD
& EDGE.)
(FRONT,BACK
ON 18 THK
PLASTIC
PLASTIC LAMINATE
VCB
PLYWD FRONT(TYP.)
(TOP, BOTTOM & EDGE.)
ADJUSTABLE SHELVES
ON 18 THK PLYWD
50X50X6X50LG
ON 18 THK PLYWD
(TOP, BOTTOM & EDGE.)
EXP BOLT @600 O.C
ADJUSTABLE SHELVES
ON 6 THK
50x100 WD
PLYWD (FRONT)TYP.
25x100 WD
ON 6 THK
PLYWD (FRONT,
ON 18 THK
BACK & EDGE)
METAL PULL(B02011)
@ EACH DRAWER)
(2PR-B01602 @ EACH DOOR)
MET PULL(B02011)
DRAWER W/ SLIDE(2PR-B05011
MET PULL (B02011)
@ 600 O.C.
50X100 WD & 50X50X6
TOP & EDGE
FRONT, BACK & EDGE W/ HINGE
18 THK PLYWOOD
VCB
6 THK PLYWOOD
18 THK PLYWOOD
SEE MECH DWG
RANGE HOOD
6 THK PLYWOOD
METAL
BOTTOM & EDGE)
25X100
PLASTIC
PLYWOOD (TOP,
HANDWARE
ADJUSTABLE
SHELF
25X100 WD
12 THK PLYWOOD
25X100
50X100 WD
50x100 WD
50X50X6X50LG
EXP BOLT @ 600 O.C
ON 6 THK
PLYWD FRONT(TYP.)
25x100 WD
VCB
THK PLYWD
& EDGE.)
(FRONT,BACK
ON 18
PLASTIC
PLYWD (FRONT,
ON 18 THK
BACK & EDGE)
METAL PULL(B02011)
ON 18THK PLYWD
(TOP, BOTTOM & EDGE.)
ADJUSTABLE SHELF
PLASTIC
ON 18
THK PLYWD
(FRONT,BACK
& EDGE.)
ON 19 THK PLYWD
ADJUSTABLE SHELF
(TOP, BOTTOM & EDGE.)
HAREWARD
MET ADJ SHELF
50X100 WD 50X100 WD
25X100
MET ADJUSTABLE
SHELF HARDWARD
MET ADJ SHELF
HARDWARE
18 THK PLYWOOD
FRONT, BACK & EDGE W/ HINGE
(2PR - B01602 @ EACH DOOR)
MET PULL (B02011)
18 THK PLYWOOD
ADJUSTIBLE SHELF (TOP,BOTTOM & EDGE)
BLOCKING(TYP.)
ON 18 THK
PLYWD (FRONT)
W/ HINGES (2PR-B01602
@ EACH DOOR)
MET ADJ SHELF
HAREWARD
METAL PULL(B02011)
METAL PULL(B02011)
W/ HINGES (2PR-B01602
@ EACH DOOR)
W/ HINGES (2PR-B01602
@ EACH DOOR)
25X100 WD
BLOCKING(TYP.)
ON 18 THK
PLASTIC LAMINATE
PLYWD (FRONT)
@ EACH DOOR)
W/ HINGES (2PR-B01602
MET ADJUSTABLE
SHELF HARDWARD
W/ HINGES (2PR-B01602
@ EACH DOOR)
PLYWD (FRONT)
ON 18 THK
12 THK
PLYWOOD
,4
,4
,4
(2PR-B01612 2 EACH DOOR)
MET PULL (B02011)
50X100 WD & 50X50X6
18 THK PLYWOOD
18 THK PLYWOOD
6 THK PLYWOOD
FRONT, BACK & EDGE W/ HINGE
@600 O.C.
TOP & EDGE
VCB
25X100 WD
6 THK PLYWOOD
KITCHEN SINK
25X50 WD
18 THK PLYWOOD
13 THK SOLID SURFACE
MATERIAL (SSM-1) OVER
(COUNTERTOP, BACK &
SIDE SPLASH)
18 THK PLYWOOD
13 THK SOLID SURFACE
MATERIAL (SSM-1) OVER
(COUNTERTOP, BACK &
SIDE SPLASH)
18 THK PLYWOOD
13 THK SOLID SURFACE
MATERIAL (SSM-1) OVER
(COUNTERTOP, BACK &
SIDE SPLASH)
PLASTIC LAMINATE(PL-1)
PLASTIC LAMINATE(PL-1)
LAMINATE(PL-1)
LAMINATE(PL-1)
PLASTIC LAMINATE(PL-2)
PLASTIC LAMINATE(PL-2)
PLASTIC LAMINATE(PL-1)
PLASTIC LAMINATE(PL-1)
PLASTIC LAMINATE(PL-2)
PLASTIC LAMINATE(PL-2)
PLASTIC LAMINATE(PL-1)
LAMINATE (PL-1)
PLASTIC LAMINATE(PL-1) ON
PLASTIC LAMINATE(PL-2) ON
PLASTIC LAMINATE(PL-2) ON
ON 18 THK
LAMINATE(PL-1)
PLASTIC LAMINATE(PL-1) ON
PLASTIC LAMINATE(PL-1) ON
PLASTIC LAMINATE(PL-1)
PLASTIC LAMINATE(PL-1) ON
ON 6 THK PLYWOOD
PLASTIC LAMINATE(PL-1)
PLASTIC LAMINATE(PL-1) ON
PLASTIC LAMINATE(PL-1) ON
PLASTIC LAMINATE(PL-2) ON
PLASTIC LAMINATE(PL-2) ON
SCALE:
AS SHOWN
KITCHEN CABINET DETAILS @ KITCHEN ON 2ND FLOOR
SCALE:1 : 10
1A
DETAIL-1
SCALE: 1 : 10
1B
DETAIL-2
SCALE: 1 : 10
1C
DETAIL-3
SCALE:1 : 10
1D
DETAIL-4
KITCHEN CABINET DETAILS
(PL-1).
PLYWD PANEL W/ PLASTIC LAMINATE
CONSTRUCTED OF SOLID WD TRIMS &
END PANEL AND ETC. SHALL BE
INCLUDING DOOR, DRAWER FRONTS, SIDE
ALL EXPOSED COUNTER CABINET FACES
5.
6.
(PL-2).
FINISHED W/ PLASTIC LAMINATE
ALL CABINET INSIDE SURFACE SHALL BE
7.
FOR THE SOUND SILENCE.
EQUIPPED WITH RUBBER BUMPER
ALL CABINET DOORS SHALL BE
AND TO BE INSTALLED BY OTHER.
GOVERNMENT FURNISHED MATERIALS
MICROWAVE,RANGE AND REFRIGERATOR WILL BE 1.
2.
3.
4.
FINISHED W/ SOLID SURFACE MATERIAL (SSM-1).
ALL CABINET COUNTERTOP SHALL BE
8.
SOLID SURFACE MATERIALS FOR APPROVAL.
OF HARDWARE, PLYWOOD, PLASTIC LAMINATE &
AND TEST REPORTS, CERTIFICATIONS
OF KITCHEN CABINETS WITH HARDWARE,
CONTRACTOR SHOULD SUBMIT SHOP DRAWING
TWO (2) INCHES ACTURAL SIZE OF THE REF.)
JOB SITE, (REFRIGERATOR SPACE SHALL BE
AND CABINET SIZE WILL BE ADJUSTED ON THE
REFRIGERATOR DIMENSION IS APPROXIMATE
SELECTED BY USING AGENCY.
PLASTIC LAMINATED COLOR TO BE
(PL-2)
W/ PLASTIC LAMINATE
25X100 WD
SSM-1
OR APPROVED EQUAL
MELATON, 1157EA
PLASTIC LAMINATED SHEET
OR APPROVED EQUAL
MELATON, 3357EA
PLASTIC LAMINATED SHEET
PL-1
PL-2
OR APPROVED EQUAL
CRYSTAL PACIFIC, #NP932
SAMSUNG STARON MFG,
SOLID SURFACE MATERIAL
CABINET NOTE
REPAIR BARRACKS S-1115
A-19
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
T O
F
L O
O R
WD FRAME
CLOTHES HANGING ROD W/
25x32 WD. NAILER W/
18 THK. PLYWD SHELF
WOOD DOOR
(SEE DOOR SCUEDULE)
VCB
1F
PVCT
1H
FINISH(POST FRAMING COUNTER TOP)
ANCHOR BOLT
@ 450 O.C
25X50 WD.
SPACER
WOOD DOOR
C E
IL
IN
G
H
G T
SEALANT
#2 OR #4
DOOR FRAME
VARNISH ON
1B
1C
SEALANT #2 OR #4
(BELOW TOP)
FILLER PANEL
WOOD DOOR
MATERIAL
BACK STOP
O R
CABINET
TOP OF
CABINET WALL
1D
1E
1H
O R
HD.WD.TRIM
12 THK. GWB
CEILING
WD. DOOR
WD. DOOR FRAME
WD. FRAME
CEILING
12 THK. GWB
SHELF CLOTHES
HANGING ROD
PROVIDE A FACE PANEL AT EACH END
THE CLOSET DOORS ARE OPEN
DRAWER WIDTH SHALL BE 500 mm.
DRAWERS TO OPEN FULLY WHEN
OF DRAWER UNIT TO ALLOW THE
X NOTE ;
PLYWOOD W/PLASTIC LAM(PL-1)
EXST CMU
PAINT ON
20x40 WD. TRIM
VARNISH ON EXST
GWB WALLS
PAINT ON EXST
WD. DOOR FRAME
VARNISH ON EXST
WD. DOOR FRAME
VARNISH ON EXST
HD. WD. TRIM
VARNISH ON EXST
EXST CMU
PAINT ON
PLASTIC LAMINATE(PL-1) ON
PAINT ON CMU
VARNISH ON EXST
EXST TRIM
VARNISH ON EXST
VARNISH ON EXST
VARNISH ON EXST
EXST CMU
PAINT ON
VARNISH ON EXST
20x50 WD TRIM
VARNISH ON EXST
TC ON
TC ON
CABINET
DRAWER
CLOSET DETAILS
SCALE:
AS SHOWN
CLOSET DETAILS
A-15
A-15
SCALE:
1H
SECTION
SCALE:
1A
CLOSET PLAN
1 : 30
1 : 5
SCALE:
1B
PLAN DETAIL
1 : 5 SCALE:
1C
HEAD DETAIL
1 : 5
SCALE:
1D
1 : 30
ELEVATION
SCALE:
1E
SECTION DETAIL
SCALE:
1F
JAMB DETAIL
SCALE:
1G
1 : 5
PLAN DETAIL
1 : 5 1 : 5
1G
VARNISH ON EXST
20x50 WD TRIM
20x50 WD TRIM
VARNISH ON EXST
116509
50 EQ EQ195 50
15010001000
,8
,2
,4
PAINT ON WALL
A-15
SST PLATE
CLOTHES
POSTFORM
HANGING ROD
BRACKET
25 DIA SST PIPE
PLASTIC LAMINATE
ON 18 THK PLYWOOD
W/ 9 DIA EXP BOLT
BOTH SIDES-SHELF
PLASTIC LAMINATE
& SIDE PANEL
ON 18 THK PLYWOOD
REPAIR BARRACKS S-1115
A-20
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
ABBREVIATION
ROOM NAMESROOM NOS
INTERIOR FINISH SCHEDULE
FLOOR BASE WALLS CEILING
REMARKS
FINISH COLOR FINISH COLOR FINISH COLOR FINISH COLOR HEIGHT
SURFACE
ROOFING
FLASHING
FASCIA
SOFFIT
DOOR & FRAME
HANDRAIL
MATERIAL
ROOF LINER
STEEL
STEEL PIPE
COLOR
CHOCOLATE
COLOR NO.
20095
CHOCOLATE
CHOCOLATE
CHOCOLATE
CHOCOLATE
CHOCOLATE
20095
20095
20095
20095
20095
REMARKS
WALL EIFS
WALL CMU
BEAM/COL CONC
STAIR CONC
SAND-STONE
SAND-STONE
SAND-STONE
SAND-STONE
23617
23617
23617
23617
PROTECTED METAL
PROTECTED METAL
PROTECTED METAL
EXTERIOR COLOR SCHEDULE-1
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FIRE EXTINGUISHER CABINETFEC
GYPSUM WALL BOARD
SOUND ABSORPTION WALL PANEL
QT QUARRY TILE
VINYL COVE BASE
SPRAY TEXTURE
VCB
ST
SAWP
FACTORY FINISH
HARDENER
PROTECTED METALPM
GWB
HDR
FF
CERAMIC MOSAIC TILE
EXTERIOR INSULATION & FINISH SYSTEM
CHAIN-LINK PARTITION
CMT
CP
EIFS
ACOUSTICAL TILEACST
CMU CONCRETE MASONRY UNIT
CPL CEMENT PLASTER
PVCT
ATT ASPHALT TIRE TILE
MATERIAL & COLOR SCHEDULE
FLOOR MATERIAL/COLOR BASE MATERIAL/COLOR
WALL MATERIAL/COLOR
CEILING MATERIAL/COLOR
PVCT-1
OR APPROVED EQUAL
457.2MMx457.2MM, 3MM THK
KCC SENSE TILE, CERAMIC, TN2412C
PVC TILE VCB-1
ACST-1
OR APPROVED EQUAL
WHITE
MC 3102 (3S)
"KCC MITONE"
603MM x 603MM x 15MM THK
ACOUSTICAL CEILING TILE
PVC TILE
MAT'L
EXST
MAT'L
NEW
MAT'L
EXST
MAT'L
NEW
MAT'L
EXST
MAT'L
NEW
MAT'L
NEW
MAT'L
EXST
VCBPVCT VCB
VCBPVCT
CMT --
VCB
PVCT
F.F.
F.F.
F.F.
F.F.
F.F.
F.F.
PVCT-1
CMT-1
PVCT-1
CMT-1
F.F.
F.F.
F.F.
VCB-1
VCB-1
GCWT GCWT
RB PAINT
F.F.
PT-1
GWB
GWB GWB
GWB
GWB
GWB*
GWB*
PAINT
PAINT
PAINT
TC-1
PT-2
PT-2
TC-1
PT-2
2300 GWB* : WATER RESISTANT TYPE
GWB* : WATER RESISTANT TYPE
VESTIBULE
VCBPVCT VCBF.F. PVCT-2 F.F. VCB-1 CMU PAINT PT-1
-CMU
CDA-300, CLEAR COATING
HDR-1
NOROO, DENSIL
OR APPROVED EQUAL
CONC. W/
HARDENER
CONC VAR
HARDENER
RT-1 RUBBER TILE
OR APPROVED EQUAL
LIVING / SLEEPING
DRESSING
BATH ROOM
VCT
VCT
CMT
VCTCLOSET
101 THRU 122
201 THRU 226
401 THRU 426
301 THRU 326
PVCT-1 VCB VCB
CMU/CPL -/-
CMU/GWB
GCWT GCWT F.F.
CMU/GWB PAINT PT-1
GWB
GWB
GWB
LAUNDRY123
124,228,328,428 STAIR-1 RT RT RT-1 RB RB-1 CMU - CONC/GWB -/GWB VAR/2400* 2400* : 4TH FLOOR ONLY
125 LOBBY - GWB/ACST GWB/ACST PAINT/F.F
ACST-1
TC-1/
JANITOR CLOSET126,229,329,429 GWB* PAINT PT-2 GWB* : WATER RESISTANT TYPE- CMU/GWB
TOILET F.F. CMT-1 - GWB* PAINT PT-2 2400 GWB* : WATER RESISTANT TYPECMT - - - GCWT GCWT F.F. GWB
128 CLOSET VCBPVCT VCBF.F. PVCT-2 F.F VCB-1 GWB GWB PAINT PT-2 2400VCT PAINT PT-1CMU -
129 MUD ROOM EPOXY EPOXY EP-1 GWB* PAINT PT-2 2400 GWB* : WATER RESISTANT TYPEGCWT GCWT F.F. GWB
F.F.QT QT QT-1 QTB QTB F.F QTB-1 PAINT PT-1 GWB GWB PAINT TC-1 2616
VCBPVCT VCBF.F. PVCT-2 F.F VCB-1 ACST ACST 2400VCT CMU/GWB -/GWB F.F ACST-1
VCB VCBF.F. F.F VCB-1 ACST ACST 2700F.F ACST-1
133,135,230,231, 330,331,430,431
STORAGE
CONC. W/
HARDENER
CMU CONCEPOXY EP-1 - VAR*- VAR* : 3270 @1ST FL, 2870 @2ND, 3RD FL- - - -
MECH ROOM
COATING
COATING
- - - - CMU/SAWP - - -
CORRIDOR136,232,332,432 VCBPVCT VCBF.F. PVCT-2 F.F VCB-1 ACST ACST 2400CMU/CPL F.F ACST-1-/-
333,334,433,434
137,138,233,234 VESTIBULE -CMUF.F.QT QT QT-1 QTB QTB F.F QTB-1 PAINT PT-1 GWB GWB PAINT TC-1 2400
STAIR-2139,235,335,435 -EIFS PAINT CONC PAINT VAR- - - - -
STAIR-3140,236,336,436 -EIFS PAINT CONC PAINT VAR- - - - -
COMM CONC. W/
HARDENER
- - - - -CMU PAINT PT-1 CONC/GWB PAINT PT-2-/GWB VAR/2400* 2400* : 4TH FLOOR ONLY
KITCHEN/ DINING
LOUNGE
GAME ROOM427
227 VCBPVCT VCBF.F. PVCT-2 F.F VCB-1VCT
VCBPVCT VCBF.F. PVCT-2 F.F VCB-1VCT
VCBPVCT VCBF.F. PVCT-2 F.F VCB-1VCT
CMU/AWP -/GWB GWB/ACST GWB/ACST PAINT/F.F
ACST-1
TC-1/
CMU/AWP GWB/ACST GWB/ACST PAINT/F.F
CMU/AWP GWB/ACST GWB/ACST PAINT/F.F
RB-1 RUBBER BASE
TC-1
ACST-1
TC-1/
ACST-1
TC-1/
QT-1
#Q06,FAWN GRAY
152X152X12THK
AMERICAN OLEAN
AMERICAN OLEAN
QTB-1
W/ ABRASIVE GRAIN
#Q06,FAWN GRAY
COVE ROUND TOP
127X152X12THK
CUBI TEX SYSTEM MFG BY DAIHAN PAINT OR
BON TILE MFG BY KUNSUL…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .