Drawings 6-2026.pdf
PDF 8 MB Posted
- Attached to
- Center Green Fountain Updates
- Solicitation number
- GL-2027-10
- Issued by
- Hartford County, Connecticut
About this file
This is a comprehensive set of architectural and engineering drawings for the Glastonbury Center Park Fountain renovation project located at 2340 Main Street, Glastonbury, Connecticut, prepared for the Town of Glastonbury Parks Department. The project scope includes complete demolition and replacement of the existing fountain system, including removal of piping, pumps, filters, and electrical equipment currently housed in an underground vault, with relocation of control and electrical systems to an above-ground NEMA 3R rated enclosure. The work encompasses mechanical modifications involving Schedule 80 PVC piping replacement to a depth of 5 feet beyond the fountain walls, replacement of two 1 HP Pentair Whisperflo pumps, a Pentair Clean & Clear filter system, and associated valves and gauges; plumbing work including new skimmers, main drains, and fountain nozzles from manufacturers including Hayward and Long Island Foundation; electrical work involving new panelboards, timeclocks, GFCI receptacles, LED lighting fixtures, site lighting circuits, and underground conduit installation; and structural/architectural work consisting of fountain wall repointing, concrete crack and spall repair, plaster restoration, waterproofing membrane application, and exterior stone masonry work. The drawings include detailed cross-sections, elevation views, equipment schedules, and specifications for material standards including compliance with NFPA 70, NEC, Connecticut Building Code, and NETA acceptance testing standards.
The project documentation specifies that all work must be completed in accordance with applicable state and local building codes and that the contractor is responsible for obtaining all necessary permits and providing shop drawings for approval prior to material ordering. The contractor must maintain one-year manufacturer warranties on all equipment and provide comprehensive operations and maintenance manuals, as-built drawings in AutoCAD format, and coordination drawings detailing equipment locations and clearances. Electrical work requires NETA ATS acceptance testing performed by qualified technicians, with minimum seven days' notice to the architect and engineer. The drawings indicate base bid and alternate bid options, with the base bid scope focusing on piping replacement to specified depths and alternate work including buried piping replacement. All materials must be pressure-tested and scoped with detention devices to confirm pipe routes and functions, with documentation of pipe sizes and creation of as-built schematics for architect review prior to substantial completion.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A2 A5
A5
S
L O
P E
SLOPE
LO
P E
S
LO
P E
S L O
P
SLOPE
P
P E
O V
E R
F L O
W D
R A
IN
T O
C A T C H B
A S
IN
A3
A3
A4
A4
A42
A4
A4
A4
A4 6
A4
VAULT DRAIN
TRENCH HATCHED AREA
FOLLOWING DRAINAGE AND
SUPPLY LINE. DRAINAGE AND
SUPPLY LINE TO BE REMOVED
AND REPLACED WITH NEW.
CAREFULLY REMOVE AND
SALVAGE EXISTING BRICK
PAVERS FOR REINSTALLATION.
SAWCUT THROUGH SLAB ON
GRADE AND TRENCH HATCHED
AREA FOLLOWING DRAINAGE
AND SUPPLY LINE. DRAINAGE
AND SUPPLY LINE TO BE
REMOVED AND REPLACED
WITH NEW.
CAREFULLY REMOVE BLUESTONE
COPING IN ITS ENTIRETY FROM
FOUNTAIN HALF WALL.
REMOVE AND DISPOSE
OF EXISTING FOUNTAIN
SUPPLY AND RETURN
PIPES.
A2
EXISTING EQUIPMENT
VAULT TO REMAIN
PROTECT TREE ROOT ZONE AT
ALL TREES. DO NOT PARK OR
STORE MATERIALS WITHIN DRIP
LINE OF TREES.
A2
B A
S E
B
ID
R
EP
LA
C
E P
IP
IN
G T
O
B A S E B
ID
R E P L A C E P
IP
IN
G T O
B A S E B
ID
R E P L A C E P
IP
IN
G T
O
A L T E R N A
TE
R E P L A C E B
UR
IE
D P
IP
IN
G
A L T E R
N A T E
R E P L A C E B
U R
IE
D
P
IP
IN
G
(MD1)
(MD2)
(FN1)
(MD3)
(OF1)
(I1)
(I2)
(SK-1)
TEMPORARY FENCING
1. PIPING SCHEMATIC IS BASED ON AVAILABLE
INFORMATION. CONTRACTOR SCOPE OF WORK
SHALL INCLUDE THE FOLLOWING:
2. BASE BID:
ALTERNATE #1:
• PRESSURE TEST ALL PIPING
• SCOPE ALL PIPES WITH DETENTION
DEVICE TO CONFIRM PIPE ROUTE AND
FUNCTION.
• CONFIRM PIPE SIZES AND DOCUMENT SIZE
WITH FUNCTION.
• CREATE A SCHEMATIC AS-BUILT SKETCH
FOR ARCHITECT'S REVIEW.
• REPLACE ALL FITTINGS WITHIN THE
FOUNTAIN.
• REPLACE ALL PIPING WITHIN THE FOUNTAIN
TO A POINT 5'-0" BEYOND THE OUTSIDE
FACE OF WALL.
• REPLACE PUMPS, FILTER AND ALL PIPING
VALVES, "GAUGES" AND METERS WITHIN
THE VAULT, AND TO A POINT 5'-0"
BEYOND THE OUTSIDE FACES OF WALL.
• REPLACE REMAINING PIPING BETWEEN
FOUNTAIN & VAULT.
3. PIPES TO BE SCHEDULE 80 PVC FOR ALL
EMBEDDED OR BURIED PIPES. EXPOSED PIPING
IN VAULT MAY BE SCHEDULE 80 OR SCHEDULE
40, BY CONTRACTOR'S OPTION.
4. ALL BURIED PIPING TO BE PITCHED TO ALLOW
GRAVITY DRAWING FOR WINTERIZATION. PIPING
TO BE BEDDED IN SAND.
FOUNTAIN SUPPLY & RETURN TO/FROM P1 & P2
SKIMMER & MAIN DRAIN TO PUMP P1
FILTERED WATER RETURN
FOUNTAIN DRAIN & VAULT DRAIN
FILL LINE
BALL VALVE
G.BAR - OPERATED VALVE
FLOW METER
LEGEND:
ISSUANCES
NO. DATE DESCRIPTION
DATE:
PROJECT NO:
DRAWN:
CHECKED:
ISSUED FOR:
REVISIONS:
SEAL:
SHEET NO.
CES #260274.00
TLBA
GROUND DEMO
FLOOR PLAN
GLASTONBURY
CENTER PARK
FOUNTAIN
2340 MAIN STREET,
GLASTONBURY, CT
06033
2026.005
LDP
MPF
BID
A1
06/24/2026
1/4" = 1'-0"1 SITE DEMOLITION PLAN
NO SCALE
GENERAL NOTES
NOTE: SEE DRAWING A3 FOR
EXTENTS OF CONCRETE REMOVAL
& PIPE/FITTING REPLACEMENT
REVISIONS
NO. DATE DESCRIPTION
GRADE
0"
FOUNTAIN F.F.
3 1/2"
T/O FOUNDATION
FOOTING
-4'-0"
1'-6"
ABRASIVE BLAST AND REMOVE EXPOSED
AGGREGATE CONCRETE FINISH ON CONCRETE WALL
SUBSTRATE AND CONCRETE SLAB ON GRADE.
CAREFULLY SAWCUT AND REMOVE SKIMMER
GRADE
0"
FOUNTAIN F.F.
3 1/2"
T/O FOUNDATION
FOOTING
-4'-0"
1/
REMOVE CAPSTONE
COPING
CAREFULLY
SAWCUT 1" DEEP
ABOVE SKIMMER
REMOVE AND DISCARD
EXISTING SKIMMER AND
PIPING
CAREFULLY CHIP CONCRETE
AROUND SKIMMER TO PREVENT
DAMAGE TO REINFORCEMENT.
ABRASIVE BLAST EXPOSED
AGGREGATE CONCRETE FINISH
NOTE:
DEMO AT INLETS AND OUTLETS SIMILAR.
ABRASIVE BLAST
EXPOSED AGGREGATE
CONCRETE FINISH
CAREFULLY SAWCUT 1" DEEP
AND CHIP CONCRETE AT
TRENCH. DO NOT DAMAGE
REINFORCEMENT.
GRADE
0"
FOUNTAIN F.F.
3 1/2"
T/O FOUNDATION
FOOTING
-4'-0"
A2
1'-6"
ISSUANCES
NO. DATE DESCRIPTION
DATE:
PROJECT NO:
DRAWN:
CHECKED:
ISSUED FOR:
REVISIONS:
SEAL:
SHEET NO.
CES #260274.00
TLBA
DEMOLITION
FOUNTAIN SECTIONS
GLASTONBURY
CENTER PARK
FOUNTAIN
2340 MAIN STREET,
GLASTONBURY, CT
06033
2026.005
LDP
MPF
BID
A2
06/24/2026
1/2" = 1'-0"5 DEMOLITION CROSS SECTION THROUGH MAIN DRAIN @ FOUNTAIN
1 1/2" = 1'-0"2 WALL DEMO SECTION @ SKIMMER
1 1/2" = 1'-0"6 DEMO AT FLOOR TRENCH
1/2" = 1'-0"1 DEMOLITION CROSS SECTION THROUGH SKIMMER
GRADE
0"
T Y P
V .I .F
TYP.
V.I.F. 9'-6 3/4" +/-
GRADE
0"
GRADE
0"
A2
GRADE
0"
A2
A2
GRADE
0"
REMOVE AND REPLACE ELECTRICAL BOX. REFER
TO 'E' DRAWINGS FOR ADDITIONAL INFORMATION
PATCH AND REPAIR EXISTING MASONRY STONE
EXTERIOR AS NEEDED.
GRADE
0"
GRADE
0"
A2
PROTECT PLAQUE FROM
DAMAGE AND CLEAN PRIOR
TO SUBSTANTIAL COMPLETION
GRADE
0"
A2
A2
ISSUANCES
NO. DATE DESCRIPTION
DATE:
PROJECT NO:
DRAWN:
CHECKED:
ISSUED FOR:
REVISIONS:
SEAL:
SHEET NO.
CES #260274.00
TLBA
DEMOLITION
FOUNTAIN EXTERIOR
ELEVATIONS
GLASTONBURY
CENTER PARK
FOUNTAIN
2340 MAIN STREET,
GLASTONBURY, CT
06033
2026.005
LDP
MPF
BID
A4
06/24/2026
1/2" = 1'-0"4 EXTERIOR FOUNTAIN WALL
1/2" = 1'-0"3 EXTERIOR FOUNTAIN WALL
1/2" = 1'-0"2 EXTERIOR FOUNTAIN WALL
1/2" = 1'-0"1 EXTERIOR FOUNTAIN WALL
1/2" = 1'-0"8 EXTERIOR FOUNTAIN WALL
1/2" = 1'-0"7 EXTERIOR FOUNTAIN WALL
1/2" = 1'-0"6 EXTERIOR FOUNTAIN WALL
1/2" = 1'-0"5 EXTERIOR FOUNTAIN WALL
SCOPE OF WORK AT EXTERIOR STONE FACE:
1. POWER WASH ALL SURFACES.
2. REMOVE CAP STONE AND PROTECT TOP OF WALL FROM DAMAGE AND
WATER INFILTRATION. REPAIR TOP OF WALL. INCLUDING SPALLS AND CRACKS.
REPOINT STONE BY CUTTING ALL JOINTS 1/2" DEEP AND REPOINTING WITH
PORTLAND CEMENT MORTAR TO MATCH COLOR AND TEXTURE OF EXISTING.
3. CLEAN STONE OF ANY MORTAR DROPPINGS AND HAZE USING MILD SOLUTION.
ONLY USE ACID SOLUTION WHERE/IF NECESSARY.
P1
P2
F1
GUTTER
DRAIN LINE
VAULT DRAIN
VAULT ACCESS DOOR ABOVE.
KEEP AREA BELOW CLEAR OF
PIPING AND EQUIPMENT.
CAREFULLY SAWCUT FLOOR
SLAB IN PREPARATION OF NEW
4" STRUCTURAL SLAB.
SKIMMER SUPPLY
MAIN DRAIN SUPPLY
FILTERED
WATER RETURN
DISCHARGE
TO FILTER
FOUNTAIN
RETURN
FOUNTAIN
SUPPLY
FOUNTAIN FILL LINE
EXISTING BACKFLOW
PREVENTER TO REMAIN
FM
FM
ELECTRICAL EQUIPMENT
RE: E DRAWINGS FOR
ADDITIONAL INFORMATION
A2
FN1
MD2
MD1
MP3
OF1
SK-1
A2
EXCAVATE HATCHED AREA
FOLLOWING DRAINAGE AND
SUPPLY LINE. DRAINAGE AND
SUPPLY LINE TO BE REMOVED
AND REPLACED WITH NEW.
A2
I1
FI
LL
L
IN
E
I2
FOUNTAIN SUPPLY & RETURN TO/FROM P1 & P2
SKIMMER & MAIN DRAIN TO PUMP P1
FILTERED WATER RETURN
FOUNTAIN DRAIN & VAULT DRAIN
FILL LINE
BALL VALVE
G.BAR - OPERATED VALVE
FLOW METER
LEGEND:
P1
P2
F1
FM1
FM2
TAG DESCRIPTION MAKE/MODEL
FILTER PUMP
FOUNTAIN PUMP
FILTER
FLOW METER
FLOW METER
PENTAIR, WHISPERFLO, 1 HP
PENTAIR, WHISPERFLO, 1 HP
PENTAIR, CLEAN & CLEAR, CC 100
BLUE - WHITE, F-300
BLUE - WHITE, F-300
BALL - VALVE JANDY, UNIONIZED - PVC
GEAR - OPERATED VALVE JANDY WITH G. BAR HANDLE
FN1 FOUNTAIN NUZZLE LONG ISLAND FOUNDATION CO., NLC-125
MDI-3 MAIN DRAIN HAYWARD, WG 1061, 8"
IL-1&2 INLET HAYWARD, SP 1419
OF-1 OVERFLOW FITTING CRYSTAL FOUNTAIN, DOA
SK-1 SKIMMER HAYWARD, SP 1099S, OPEN FRONT
ISSUANCES
NO. DATE DESCRIPTION
DATE:
PROJECT NO:
DRAWN:
CHECKED:
ISSUED FOR:
REVISIONS:
SEAL:
SHEET NO.
CES #260274.00
TLBA
ENLARGED DEMO
PIPING PLAN
GLASTONBURY
CENTER PARK
FOUNTAIN
2340 MAIN STREET,
GLASTONBURY, CT
06033
2026.005
LDP
MPF
BID
A3
06/24/2026
1/2" = 1'-0"1 PUMP ROOM PIPING PLAN
1/2" = 1'-0"2 FOUNTAIN PIPING PLAN
1" = 1'-0"
EQUIPMENT SCHEDULE
1'-6"
3'-4"
1'
1'
2'-7"
1'-0"
1'
SKIMMER
ISSUANCES
NO. DATE DESCRIPTION
DATE:
PROJECT NO:
DRAWN:
CHECKED:
ISSUED FOR:
REVISIONS:
SEAL:
SHEET NO.
CES #260274.00
TLBA
FOUNTAIN INTERIOR
ELEVATIONS
GLASTONBURY
CENTER PARK
FOUNTAIN
2340 MAIN STREET,
GLASTONBURY, CT
06033
2026.005
LDP
MPF
BID
A5
06/24/2026
1/2" = 1'-0"1 INTERIOR FOUNTAIN WALL
1/2" = 1'-0"8 INTERIOR FOUNTAIN WALL
1/2" = 1'-0"3 INTERIOR FOUNTAIN WALL
1/2" = 1'-0"5 INTERIOR FOUNTAIN WALL
1/2" = 1'-0"7 INTERIOR FOUNTAIN WALL
1/2" = 1'-0"2 INTERIOR FOUNTAIN WALL
1/2" = 1'-0"4 INTERIOR FOUNTAIN WALL
1/2" = 1'-0"6 INTERIOR FOUNTAIN WALL
NOTE:
FOR PURPOSES OF BID ASSUME 25% OF CRACKS
IN PLASTER REDUCE CONCRETE CRACK REPAIR AFTER
PLASTER REMOVAL ASSUME 25 SF OF CONCRETE SPALL REPAIR.
SEE DRAWINGS A6,A7 & A8 FOR REPAIR METHODS.
2'-0"
1 3/4"2"
2 3/4"
CHAMFERED EDGE
DRIP EDGE
LIQUID APPLIED
WATERPROOFING MEMBRANE
EQUIVALENT TO LATICRETE
HYDRO SEAL
PLASTER TO BE EQUIVALENT
TO "RADIANT TEXTURED" FINISH
AS MANUFACTURED BY PEBBLE
TECHNOLOGY INTERNATIONAL
CAST STONE COPING
EXISTING STONE TO
REMAIN. REPOINT, TYP.
CONTINUOUS FABRIC/METAL
THROUGH WALL FLASHING
EQUIVALENT TO YORK 'MULTI-
FLASH STAINLESS STEEL'
1/8" SLOPE
STAINLESS STEEL PIN
(2) PIER PIECE
REPOINT, TYP.
GRADE
0"
LIQUID APPLIED
WATERPROOFING MEMBRANE
EQUIVALENT TO LATICRETE
HYDRO SEAL
PORTLAND CEMENT BASED
MORTAR PARGE COAT TO
PROVIDE SUITABLE SURFACE FOR
NEW PLASTER FINISH
EXISTING STONE TO
REMAIN.
PLASTER TO BE EQUIVALENT
TO "RADIANT TEXTURED" FINISH
AS MANUFACTURED BY PEBBLE
TECHNOLOGY INTERNATIONAL
REPOINT, TYP.
HAYWARD, WG 1061, 8",
(REFER TO PLUMBING
DWGS FOR EQUIP. DETAIL)
RE: APPROVED
SHOP DWGS FOR
PIPE CONNECTION
REQUIREMENTS
EXISTING SLAB AND 3 1/4" RETROFIT PVC
WATERSTOP, SET IN MANUFACTURER'S
ADHESIVE (SIMILAR ON OTHER SIDE)
4" EMBEDMENT OF THREADED ROD
GRADE
0"
FOUNTAIN F.F.
3 1/2"
T/O FOUNDATION
FOOTING
-4'-0"
A6
A6
WEEPHOLE BEYOND
SEALANT AND
BACKER ROD
PRECAST
CONCRETE COPING
STAINLESS STEEL
FLASHING
HAYWARD SP1099S
SKIMMER (REFER TO
PLUMBING DWGS FOR
EQUIP. DETAIL)
LIQUID APPLIED
WATERPROOFING
MEMBRANE EQUIVALENT TO
LATICRETE HYDRO SEAL
PORTLAND CEMENT
BASED MORTAR PARGE
COAT TO PROVIDE
SUITABLE SURFACE FOR
NEW PLASTER FINISH
GRADE
0"
FOUNTAIN F.F.
3 1/2"
T/O FOUNDATION
FOOTING
-4'-0"
"1'
1/
A6
A6
A6
ISSUANCES
NO. DATE DESCRIPTION
DATE:
PROJECT NO:
DRAWN:
CHECKED:
ISSUED FOR:
REVISIONS:
SEAL:
SHEET NO.
CES #260274.00
TLBA
EXTERIOR DETAILS
GLASTONBURY
CENTER PARK
FOUNTAIN
2340 MAIN STREET,
GLASTONBURY, CT
06033
2026.005
LDP
MPF
BID
A6
06/24/2026
3" = 1'-0"6 COPING CAP DETAIL
3" = 1'-0"5 POOL CURB DETAIL
1/2" = 1'-0"1 CROSS SECTION THROUGH FOUNTAIN
1 1/2" = 1'-0"9 WALL SECTION @ SKIMMER
3" = 1'-0"7 MAIN DRAIN DETAIL
ISSUANCES
DATE:
PROJECT NO:
DRAWN:
CHECKED:
ISSUED FOR:
REVISIONS:
SEAL:
SHEET NO.
CES #260274.00
TLBA
CONCRETE REPAIR
DETAILS
GLASTONBURY
CENTER PARK
FOUNTAIN
2340 MAIN STREET,
GLASTONBURY, CT
06033
2026.005
LDP
MPF
BID
A7
06/24/2026
DATE:
PROJECT NO:
DRAWN:
CHECKED:
ISSUED FOR:
REVISIONS:
SEAL:
SHEET NO.
CES #260274.00
TLBA
CONCRETE REPAIR
DETAILS
GLASTONBURY
CENTER PARK
FOUNTAIN
2340 MAIN STREET,
GLASTONBURY, CT
06033
2026.005
LDP
MPF
BID
A8
06/24/2026
DATE:
PROJECT NO:
DRAWN:
CHECKED:
ISSUED FOR:
REVISIONS:
SEAL:
SHEET NO.
CES #260274.00
TLBA
CONCRETE REPAIR
DETAILS
GLASTONBURY
CENTER PARK
FOUNTAIN
2340 MAIN STREET,
GLASTONBURY, CT
06033
2026.005
LDP
MPF
BID
A9
06/24/2026
M
TIMECLOCK
FOR LIGHT
POLES
TIMECLOCK
FOR "SPRAY
HEAD"
WIREWAY
SQUARE D
CONTACTOR
100A 120/240V
MCB LOAD
CENTER
100A
JUNCTION BOX
FOR
IRRIGATION
CONTROL
CIRCUITS - ETR
TORO -
IRRIGATION
CONTROLLER
EXISTING 100A,
120/240V, 1⌀, 3W
PEDESTAL METER
SOCKET - ETR
EXISTING UNDERGROUND
CONCRETE VAULT
ELEVATION A
PRESERVE (3) OUTGOING SITE LIGHTING
BRANCH CIRCUITS FOR RECONNECTION
TO NEW CONTACTOR AND TIMECLOCK
DURING NEW WORK PHASE. RELOCATE
EXISTING TIMECLOCK TO NEW
OUTDOOR ENCLOSURE DURING NEW
WORK PHASE
REMOVE EXISTING TIMECLOCK FOR
"SPRAY HEAD" AND TURN OVER TO
TOWN OF GLASTONBURY
REMOVE EXISTING CONTACTOR FOR
SITE LIGHTING CIRCUITS AND
PRESERVE FOR RELOCATION TO
NEW ELECTRICAL SERVICE
EQUIPMENT ENCLOSURE
REMOVE EXISTING IRRIGATION
CONTROLLER AND PRESERVE FOR
RELOCATION TO NEW ELECTRICAL
SERVICE ENCLOSURE D DURING
NEW WORK PHASE
REMOVE EXISTING WIREWAY
REMOVE EXISTING FEEDER FROM
PEDESTAL TO EXISTING LOAD CENTER
M
JUNCTION BOX
FOR
IRRIGATION
CONTROL
CIRCUITS - ETR
EXISTING 100A,
120/240V, 1⌀, 3W
PEDESTAL METER
SOCKET - ETR
EXISTING UNDERGROUND
CONCRETE VAULT
ELEVATION A
NEW WP
JUNCTION BOX
FOR EXISTING
SITE LIGHT
CIRCUITS
NEW WP
JUNCTION BOX
FOR EXISTING
SITE LIGHT
CIRCUITS - ETR
NEW WP
JUNCTION BOX
FOR NEW AND
EXISTING
INCOMING
CIRCUITS
PROVIDE 3#3, #8G IN 1-1/4"C FROM
EXISTING PEDESTAL METER SOCKET
TO NEW 100A MCB IN NEW SERVICE
EQUIPMENT ENCLOSURE. REFER TO
TRENCHING DETAIL ON E1.00
PROVIDE (3) 2#12,#12G CIRCUITS
INTERCEPTING EXISTING SITE
CIRCUITS TO NEW PANEL PP-1
NEW ELECTRICAL SERVICE EQUIPMENT
ENCLOSURE. REFER TO DETAIL 7/E1.00
PROVIDE (2) 1-1/4”C FROM NEW
ELECTRICAL SERVICE EQUIPMENT
ENCLOSURE TO EXISTING
PENETRATION IN EXISTING
UNDERGROUND CONCRETE VAULT
SECTION A
SECTION B
SECTION C
SECTION D
EXISTING FILTER TO
BE REMOVED
EXISTING FOUNTAIN
PUMP TO BE
REMOVED
EXISTING ELECTRICAL EQUIPMENT TO
BE REMOVED
EXISTING JUNCTION BOX
FOR IRRIGATION CIRCUITS
SECTION A
SECTION B
SECTION C
SECTION D
EXISTING JUNCTION BOX
FOR IRRIGATION CIRCUITS
A
P-2
P-1
WP,GFI
CONNECT NEW LIGHT
FIXTURE TO
CONNECT NEW LIGHT FIXTURE TO
EXISTING LIGHTING CIRCUIT
PRESERVED DURING DEMOLITION
7,PP-1
EXISTING UNDERGROUND
CONCRETE VAULT
ELEVATION C
EXISTING RECEPTACLES
WITH WEATHERPROOF
COVERS TO BE REMOVED
INCANDESCENT
PORCELINE LAMP
HOLDER TO BE REMOVED.
PRESERVE EXISTING
LIGHTING CIRCUIT FED
FROM METER SOCKET
PEDESTAL FOR REUSE IN
NEW WORK PHASE
EXISTING UNDERGROUND
CONCRETE VAULT
ELEVATION C
PROVIDE NEW GFCI
RECEPTACLE WITH
WEATHERPROOF COVERS.
PROVIDE 2#12,#12G IN 3/4”C
BACK TO PP-1
PROVIDE ENCLOSED AND
GASKETED IP67 RATED
LED FIXTURE, COLUMBIA
LIGHTING LXEM-4-50-ML-
RFP-E-U OR EQUIVALENT
WIRED TO EXISTING
LIGHTING CIRCUIT
PRESERVED DURING
DEMOLITION
TIMECLOCKS AND
CONTACTORS
NEMA 4 EXTERIOR RATED EQUIPMENT ENCLOSURE - HAMMOND
MAUFACTURING PART #HN4FS604818, 60" X 48" X 18"; DOUBLE DOOR
WITH 3-POINT LATCHING SYSTEM AND LOCKING HANDLE
1'-0" THICK CONCRETE PAD
60"
31.5"
48"
TOP VIEW
FRONT VIEW
18" MIN. (TYP. ALL AROUND)
9'-0" X 5'-0" CONCRETE SLAB
ON COMPACTED SUB-
GRADE - 4000 PSI WITH #5
REBAR, 12' O.C. EACH WAY
AT BOTTOM
GRADE
PANEL PP-1
120/240V
REINSTALL EXISTING TIMECLOCK FOR SITE LIGHTING CIRCUITS.
PROVIDE TORK 8001-N 120V MECHANICAL TIMECLOCK OR EQUIVALENT
TC1
C1
REINSTALL EXISTING CONTACTOR FOR SITE LIGHTING CIRCUITS.
PROVIDE (3) 20A-1P THROUGH CONTACTOR FOR SITE LIGHTING
PANEL PP-1
120/240V
PROVIDE 100A MCB, 120/240V, 1⌀,
3W, NEMA3R, 24 POLE, SCHNEIDER
QO120M100PRB OR EQUIVALENT
TC2
PROVIDE NEW TIMECLOCK FOR FOUNTAIN PUMP AND FILTER
CIRCUITS. TORK 11048 240V MECHANICAL TIMECLOCK
REINSTALL EXISTING IRRIGATION CONTROLLER AND RECONNECT TO
NEW PANELBOARD
PROVIDE NEW TIMECLOCK WIRED THROUGH SINGLE POLE SWITCH FOR
EXTERIOR FLUSH GROUND BOX FOR "CHRISTMAS TREE LIGHTS".
PROVIDE TORK 11048 240V MECHANICAL TIMECLOCK OR EQUIVALENT
TC3$
GFI
PROVIDE GFI CONVENIENCE
RECEPTACLE
ELECTRICAL ABBREVIATIONS
AMPERE
ALTERNATING CURRENT
ARC FAULT CIRCUIT INTERRUPTER
AIR CONDITIONING UNIT
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AIR HANDLING UNIT
AMPS INTERRUPTING CURRENT
ALUMINUM
AUTOMATIC TRANSFER SWITCH
AMERICAN WIRE GAUGE
BASEMENT
CONDUIT
CABLE TELEVISION
CIRCUIT BREAKER
CIRCUIT
COMPRESSOR
CONDENSATE PUMP
CURRENT TRANSFORMER
CONDENSING UNIT OR COPPER
CABINET UNIT HEATER
DRYER
DEGREE
DIAMETER
DOWN
DRAWING
EXHAUST FAN
ELECTRICAL
ELEVATOR
EMERGENCY
ELECTRIC METALLIC TUBING
EMERGENCY PANEL
ELECTRIC UNIT HEATER
ELECTRIC WATER COOLER
ELECTRIC WATER HEATER
FAHRENHEIT
FIRE ALARM
FIRE ALARM CONTROL PANEL
FOOT CANDLE
FAN COIL UNIT
GROUND
GROUND FAULT CIRCUIT INTERRUPTER
HORSE POWER
HIGH PRESSURE SODIUM
HOUR
HERTZ
ISOLATED GROUND
INCHES
JUNCTION BOX
THOUSAND CIRCULAR MILS
KILOVOLT AMPERE
KILOWATT
MAXIMUM
MAKE-UP AIR UNIT
MAIN CIRCUIT BREAKER
MOTOR CONTROL CENTER
MOLDED CASE CIRCUIT BREAKER
METAL HALIDE OR MANHOLE
MINIMUM
MAIN LUGS ONLY
NOT APPLICABLE
NATIONAL ELECTRIC CODE
NOT IN CONTRACT
NOT TO SCALE
POLE
PRIMARY ELECTRIC SERVICE
POWER FACTOR
PHASE
PANEL
POLYVINYL CHLORIDE CONDUIT
REFRIGERATOR
RIGID GALVANIZED STEEL CONDUIT
ROOM
ROOFTOP UNIT
SECONDARY ELECTRICAL SERVICE
SPECIFICATION
SWITCHBOARD
SURGE PROTECTION DEVICE
TELECOMMUNICATIONS/TELEPHONE
TELEVISION
TRANSFORMER
TYPICAL
UNIT HEATER
UNLESS OTHERWISE NOTED
VOLTS
VOLT AMPERE
VOLTS ALTERNATING CURRENT
VERIFY IN FIELD
WATT OR WIRE
WASHER
WIRE GUARD
WEATHERPROOF
A/AMP
AC
AFCI
ACU
AFF
AFG
AHU
AIC
AL
ATS
AWG
BSMT
C
CATV
C/B
CKT
COMP
CP
CT
CU
CUH
D
DEG.
DIA
DN
DWG
EF
ELEC
ELEV
EM
EMT
EP
EUH
EWC
EWH
F
FA
FACP
FC
FCU
G
GFCI
HP
HPS
HR
HZ
IG
IN
JB
KCMIL
KVA
KW
MAX
MAU
MCB
MCC
MCCB
MH
MIN
MLO
NA
NEC
NIC
NTS
P
PE
PF
PH
PNL
PVC
REF
RGS
RM
RTU
SE
SPEC
SWBD
SPD
TELE
TV
T/TX
TYP
UH
UON
V
VA
VAC
VIF
W
WA
WG
WP
J
SURFACE MOUNTED PANELBOARD
DISCONNECT SWITCH
ELECTRICAL MOTOR
BRANCH CIRCUIT WIRING, CONCEALED IN WALLS OR CEILINGS
HOMERUN TO PANELBOARD, UNLESS INDICATED OTHERWISE SHALL BE
CONNECTED TO A 1 POLE, 20 AMP CIRCUIT BREAKER
BRANCH CIRCUIT WIRING, SWITCHED
JUNCTION BOX
DUPLEX WALL MOUNTED RECEPTACLE
DUPLEX RECEPTACLE WITH GROUND FAULT CIRCUIT INTERRUPTION
SPECIAL PURPOSE RECEPTACLE, NEMA CONFIGURATION AS INDICATED
SINGLE POLE TOGGLE SWITCH
SYMBOL DESCRIPTION
ELECTRICAL SYMBOL LIST
GFCI
WATERPROOF DUPLEX RECEPTACLE
WP
SINGLE POLE TOGGLE SWITCH
18"MIN.
PLASTIC WARNING TAPE TO READ
"CAUTION BURIED UTILITY LINE BELOW"
12"
7 1/2"
(2) 1-1/4" SCHEDULE 40
PVC CONDUIT.
(1) ACTIVE, (1) SPARE
SEE NOTE 3 (TYP)
NOTES:
1. TYPICAL CONDUITS AND QUANTITIES SHOWN, REFER TO DRAWINGS FOR QUANTITIES AND
SIZES.
2. COORDINATE AND GROUP CONDUITS IN COMMON TRENCH. SINGLE ROW SHOWN, MULTIPLE
ROW DUCT BANKS ARE ACCEPTABLE, MAINTAINING SEPARATION DISTANCE REQUIREMENTS.
3. PROVIDE SUITABLE SEPARATORS AND CHAIRS 4 FT. MAX. ON CENTER, SET TO COMPACTED
TRENCH BOTTOM AND BAND CONDUITS TOGETHER PRIOR TO BACKFILL OR PLACING CONCRETE.
EXISTING BITUMINOUS
PAVEMENT
IF GRASS IS ENCOUNTERED, REGRADE,
REPAIR, AND RESEED TO MATCH
SURROUNDINGS.
SAW CUT AND REMOVE BITUMINOUS
PAVEMENT. PATCH TO MATCH EXISTING
SURROUNDING PAVEMENT
CONSTRUCTION AFTER INSTALLATION
OF FEEDER, CONDUIT OR DUCTBANK.
24" MIN.
BELOW
GRADE
SAND BEDDING 6" MINIMUM COVER ON
ALL SIDES
COMPACTED BACKFILL IN 6" LIFTS
18"MIN.
1 1/4" SCHEDULE 40 PVC
CONDUIT
24"
BELOW
GRADE
12"
NOTES:
1. TYPICAL CONDUITS AND QUANTITIES SHOWN, REFER TO DRAWINGS FOR QUANTITIES AND
SIZES.
EXISTING PAVERS
IF GRASS IS ENCOUNTERED,
REGRADE, REPAIR, AND RESEED
TO MATCH SURROUNDINGS.
COORDINATE REMOVAL AND
PRESERVATION OF EXISTING
PAVERS WITH MASON
CONTRACTOR DURING
DEMOLITION PHASE. REPAIR
TO MATCH EXISTING
SURROUNDING PAVERS
CONSTRUCTION AFTER
INSTALLATION OF CONDUIT.
SAND
BEDDING 6" MINIMUM
COVER ON ALL SIDES
COMPACTED BACKFILL
IN 6" LIFTS
PLASTIC WARNING TAPE TO
READ "CAUTION BURIED
ELECTRIC LINE BELOW"
ISSUANCES
NO. DATE DESCRIPTION
DATE:
PROJECT NO:
DRAWN:
CHECKED:
ISSUED FOR:
REVISIONS:
SEAL:
SHEET NO.
CES #260274.00
ELECTRICAL
ABBREVIATIONS,
NOTES, AND DETAILS
GLASTONBURY
CENTER PARK
FOUNTAIN
2340 MAIN STREET,
GLASTONBURY, CT
06033
06/24/2026
260247.00
KCM
SAS
E1.00
NTS
EXISTING AND DEMOLITION ELECTRICAL ELEVATION A
NTS
NEW WORK ELECTRICAL ELEVATION A
NTS
VAULT - PLAN VIEW - EXISTING AND DEMOLITION
NTS
VAULT - PLAN VIEW - NEW WORK
NTS
EXISTING AND DEMOLITION ELECTRICAL ELEVATION C
NTS
NEW WORK ELECTRICAL ELEVATION C
NTS
ELECTRICAL SERVICE EQUIPMENT ENCLOSURE
NTS
NEW SERVICE EQUIPMENT ENCLOSURE TRENCHING DETAIL
NTS
TYPICAL SITE BRANCH CIRCUIT TRENCHING DETAIL
EXISTING UNDERGROUND CONCRETE VAULT
EXISTING 100A, 120/240V, 1⌀, 3W PEDESTAL
METER SOCKET TO REMAIN. EXISTING
RECEPTACLE AND LIGHTING SWITCH TO REMAIN
NEW SERVICE EQUIPMENT ENCLOSURE. REFER
TO DETAIL ON E1.00
PROVIDE 3#3, #8G IN 1-1/4"C FROM EXISTING
PEDESTAL METER SOCKET TO NEW 100A MCB
IN NEW SERVICE EQUIPMENT ENCLOSURE.
REFER TO TRENCHING DETAIL ON E1.00
EXISTING SITE LIGHTING
(SL,ETR,CKT#1) TYPICAL
SL,ETR,CKT#3
SL,ETR,CKT1
SL,ETR,CKT#1
SL,ETR,CKT#3
SL,ETR,CKT#3
SL,ETR,CKT#5
SL,ETR,CKT#5
SL,ETR,CKT#5
SL,ETR,CKT#5
SL,ETR,CKT#5
SL,ETR,CKT#5
EXISTING FEED TO METER PEDESTAL
TO REMAIN
EXISTING ELECTRICAL BOX TO REMAIN
EXISTING IRRIGATION EQUIPMENT ENCLOSURE
PROVIDE WIREMOLD EXTERIOR FLUSH GROUND
BOX TYPE XB814 WITH XB814C520C2BK
EXTERIOR BOX COVER ASSEMBLY WITH 2 NEMA
5-20R RECEPTACLES FOR “CHRISTMAS TREE
LIGHTS”. PROVIDE 2#10,#10G IN 1-1/4”C WIRED
THROUGH TIMECLOCK TC-3 AND SINGLE POLE
SWITCH TO 20A-1P RECEPTACLE IN PP-1
COORDINATE REMOVAL AND PRESERVATION OF
EXISTING PAVERS WITH MASON CONTRACTOR
DURING DEMOLITION PHASE. REPAIR TO MATCH
EXISTING SURROUNDING PAVERS CONSTRUCTION
AFTER INSTALLATION OF CONDUIT.
REFER TO DETAIL 9/E1.00
REFER TO ADD
ALTERNATE NOTE
ON THIS DRAWING
GFI
ADD ALTERNATE: PROVIDE GFI RECEPTACLE AT EXISTING
LIGHT POLES. REMOVE ALL EXISTING WIRING SERVING SITE
LIGHTING. PROVIDE 2#10,#10G FOR NEW LIGHT POLE
RECEPTACLES AND 2#10,#10G FOR SITE LIGHTING UTILIZING
EXISTING CONDUIT. PROVIDE TOTAL OF (4) 20A-1P RECEPTACLE
CIRCUITS AND (3) 20A-1P SITE LIGHTING CIRCUITS
GFI
GFI
GFI
GFI
GFI
REFER TO ADD
ALTERNATE NOTE
ON THIS DRAWING
REFER TO ADD
ALTERNATE NOTE
ON THIS DRAWING
REFER TO ADD
ALTERNATE NOTE
ON THIS DRAWING
REMOVE EXISTING RECEPTACLE AT FOUNTAIN WALL.
COORDINATE REPAIR WITH MASON CONTRACTOR
ISSUANCES
NO. DATE DESCRIPTION
DATE:
PROJECT NO:
DRAWN:
CHECKED:
ISSUED FOR:
REVISIONS:
SEAL:
SHEET NO.
CES #260274.00
ELECTRICAL SITE
PLAN
GLASTONBURY
CENTER PARK
FOUNTAIN
2340 MAIN STREET,
GLASTONBURY, CT
06033
06/24/2026
260247.00
KCM
SAS
E2.00
1" = 10'-0"
ELECTRICAL SITE PLAN
LIGHTING FIXTURE SCHEDULE
TYPE
BASIS OF DESIGN
MANUFACTURER / MODEL
VOLTAGE SOURCE FIXTURE DESCRIPTION - BASIS OF DESIGN
A
4560LM, 38.5W
4000K LED
UNV
COLUMBIA LIGHTING LXEM
LXEM-4-40-ML-RFA-E-U
SURFACE MOUNTED, 4'x7.17"x4.4", ENCLOSED AND GASKETED FIBERGLASS LED
FIXTURE, RIBBED FROSTED ACRYLIC LENS, 80 CRI, 60,000 HOURS AT L80, WET
LOCATION LISTED
NOTES:
1. LIGHT FIXTURES IN THE SCHEDULE SHALL BE CONSIDERED BASIS OF DESIGN. EQUAL FIXTURE SUBSTITUTIONS ARE ACCEPTABLE FOR ALL FIXTURES IN THE
LIGHTING FIXTURE SCHEDULE, UNLESS INDICATED OTHERWISE. EQUAL FIXTURE APPROVAL SHALL BE AS JUDGED BY THE ENGINEER AND THE ARCHITECT.
IN ADDITION TO THE REQUIREMENTS LISTED IN THE LIGHTING FIXTURE SCHEDULE AND IN THE SPECIFICATIONS, THE PROPOSED EQUAL FIXTURES SHALL:
A. BE THE SAME GENERAL SIZE, STYLE AND SHAPE, INCLUDING BUT NOT LIMITED TO LENS CONSTRUCTION AND SHADING.
B. BE OF EQUAL QUALITY CONSTRUCTION AND FINISH.
C. BE SUPPLIED WITH ALL REQUIRED ACCESSORIES TO MATCH THE SPECIFIED (BASIS OF DESIGN) FIXTURE.
D. PROVIDE THE SAME DISTRIBUTION, EFFICACY AND SOURCE LUMEN OUTPUT.
E. HAVE THE SAME LISTINGS AS THE BASIS OF DESIGN FIXTURE, INCLUDING DLC AND ENERGY STAR QUALIFICATIONS.
2. ALL FIXTURES SHALL BE UL LISTED.
3. ALL NECESSARY MOUNTING HARDWARE, HANGERS, BRACKETS, RAILS, YOKES, CANOPIES, STEMS, CHAINS, ROW JOINERS, ETC. SHALL BE FURNISHED AND
INSTALLED.
4. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
LOAD
HP PH VOLT
REMARKS
MCA
MOTOR / EQUIPMENT CIRCUIT SCHEDULE
KW
OCPD PANEL WIRING
LOCAL
DISC. SW
GENERAL NOTES:
1. DISCONNECT SWITCHES SHALL BE HEAVY-DUTY TYPE AND SHALL BE LOCATED AT EQUIPMENT
LOCATION UNLESS OTHERWISE NOTED.
2. ABBREVIATIONS:
• MAN: MANUAL STARTER (TOGGLE SWITCH WITH THERMAL OVERLOADS)
• FVNR: COMBINATION FULL VOLTAGE NON-REVERSING STARTER/ DISCONNECT SWITCH
• VFD: VARIABLE FREQUENCY DRIVE, FURNISHED BY DIV. 23, WIRED BY DIV. 26. PROVIDE
POWER WIRING FROM SOURCE PANELBOARD TO VFD AND FROM VFD TO MOTOR(S).
COORDINATE EXACT LOCATION IN FIELD WITH DIV.23.
• DIV.21: EQUIPMENT FURNISHED BY DIVISION 21 FIRE PROTECTION CONTRACTOR
• DIV.22: EQUIPMENT FURNISHED BY DIVISION 22 PLUMBING CONTRACTOR
• DIV.23: EQUIPMENT FURNISHED BY DIVISION 23 HVAC CONTRACTOR
• SPC: SINGLE POINT CONNECTION (STARTERS INTEGRAL TO EQUIPMENT). COORDINATE
EXACT POINT OF CONNECTION IN FIELD.
3. OVERCURRENT PROTECTION DEVICES (OCPD) SHALL BE MOLDED CASE CIRCUIT BREAKERS
UNLESS NOTED WITH AN "F" FOR FUSE.
4. DISCONNECT SWITCHES AND STARTERS SHALL BE NEMA 3R RATED WHEN LOCATED OUTSIDE.
5. REFER TO PANEL SCHEDULES FOR SOURCE PANEL/ CIRCUIT INFORMATION.
6. REFER TO ELECTRICAL AND MECHANICAL PLANS FOR EXACT LOCATIONS OF EQUIPMENT.
7. STARTERS SHALL BE SQUARE D CLASS 8536 OR APPROVED EQUAL.
REFERENCED REMARKS:
1. PROVIDE WIRING FROM NEW EQUIPMENT IN EXISTING
VAULT TO NEW ELECTRICAL SERVICE EQUIPMENT
ENCLOSURE UTILIZING NEW CONDUIT FROM EXISTING
VAULT TO NEW ENCLOSURE
EQUIPMENT
MOTOR STARTER
SIZE TYPE LOCATION
1 2401 --15A-2P VARIES 30A-2P 2#12, #12G, 3/4"C SEE REMARKS 1P-1 (FILTER PUMP) SPC- AT UNIT
1 2401 --15A-2P VARIES 2#12, #12G, 3/4"C SEE REMARKS 1P-2 (RECIRC PUMP) SPC- AT UNIT30A-2P
Notes: Total Amps: 16 A
Total Load: 3.84 kVA
Phase Amps: 16 A 16 A
Phase Load: 1.92 kVA 1.92 kVA
23 24
21 22
19 SPARE 20 A 1 0.00 0.00 1 20 A SPARE 20
17 SPARE 20 A 1 0.00 0.00 1 20 A SPARE 18
15 SPARE 20 A 1 0.00 0.00 1 20 A SPARE 16
13 SITE LIGHT RECEPTACLE CKT 4 20 A 1 0.00 0.00 1 20 A CONVENIENCE RECEPT. ENCLOSURE 14
11 SITE LIGHT RECEPTACLE CKT 3 20 A 1 0.00 0.00 1 20 A SITE LIGHT RECEPTACLE CKT 2 12
9 "CHRISTMAS TREE LIGHTS" 20 A 1 0.00 0.00 1 20 A SITE LIGHT RECEPTACLE CKT 1 10
7 CONVENIENCE RECEPTACLE 20 A 1 0.00 0.96 -- -- -- 8
5 SITE LIGHTING CIRCUIT 20 A 1 0.00 0.96 2 15 A P-2 (RECIRC PUMP) 6
3 SITE LIGHTING CIRCUIT 20 A 1 0.96 0.00 -- -- -- 4
1 SITE LIGHTING CIRCUIT 20 A 1 0.00 0.96 2 15 A P-1 (FILTER PUMP) 2
CKT Circuit Description Trip Poles
A B
Poles Trip Circuit Description CKT
Enclosure: Type 1 MCB Rating / MLO: 100A MCB
Mounting: Surface Wires: 3 Bus Rating: 125 A
Supply From: Phases: 1 Bus Material: CU
Location: Volts: 120/240 A.I.C. Rating:
Branch Panel: PP-1
ISSUANCES
NO. DATE DESCRIPTION
DATE:
PROJECT NO:
DRAWN:
CHECKED:
ISSUED FOR:
REVISIONS:
SEAL:
SHEET NO.
CES #260274.00
ELECTRICAL
SCHEDULES
GLASTONBURY
CENTER PARK
FOUNTAIN
2340 MAIN STREET,
GLASTONBURY, CT
06033
06/24/2026
260247.00
KCM
SAS
E3.00
22KAICNEW ENCLOSURE
SERVICE PEDESTAL
SECTION 26 04 00 - GENERAL CONDITIONS FOR ELECTRICAL TRADES
A. DESCRIPTION
1. THIS PROJECT COMPRISES ALTERATIONS AND RENOVATIONS TO THE EXISTING BUILDING.
THE EXISTING BUILDING IS CURRENTLY OCCUPIED AND THE PROJECT WILL PROCEED IN A
MANNER WHICH WILL MINIMIZE ANY INCONVENIENCE TO THE BUILDING OCCUPANTS.
2. SCOPE OF WORK CONSISTS OF INSTALLATION OF MATERIALS TO BE FURNISHED UNDER THE
CONTRACT DOCUMENTS AND WITHOUT LIMITING GENERALITY THEREOF CONSISTS OF
FURNISHING LABOR, MATERIALS, EQUIPMENT, HOISTING, PLANT, TRANSPORTATION, RIGGING, STAGING, APPURTENANCES, AND SERVICES NECESSARY AND/OR INCIDENTAL TO PROPERLY
COMPLETE ALL WORK AS SHOWN ON THE DRAWINGS AND AS DESCRIBED HEREIN.
B. DEFINITIONS:
1. FURNISH: THE TERM "FURNISH" MEANS TO "SUPPLY AND DELIVER TO THE PROJECT SITE,
READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION, AND SIMILAR OPERATIONS."
2. INSTALL: THE TERM "INSTALL" IS USED TO DESCRIBE OPERATIONS AT PROJECT SITE
INCLUDING THE ACTUAL "UNLOADING, UNPACKING, ASSEMBLY, ERECTION, PLACING,
ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING,
CLEANING, AND SIMILAR OPERATIONS."
3. PROVIDE: THE TERM "PROVIDE" MEANS "TO FURNISH AND INSTALL, COMPLETE AND READY
FOR THE INTENDED USE.
4. REMOVE: THE TERM REMOVE MEANS TO DISCONNECT FROM ITS PRESENT POSITION;
REMOVE FROM THE PREMISES AND TO DISPOSE OF IN A LEGAL MANNER.”
5. SUBSTITUTIONS: “SUBSTITUTIONS” ARE REQUESTS FOR CHANGES IN PRODUCTS, MATERIALS
AND METHODS OF CONSTRUCTION AS PROPOSED BY THE CONTRACTOR AFTER AWARD OF
THE CONTRACT.
C. EQUIPMENT EQUIVALENTS AND SUBSTITUTIONS:
1. CERTAIN MANUFACTURERS OF MATERIAL, APPARATUS OR APPLIANCES ARE INDICATED IN
THE DRAWINGS AND SPECIFICATIONS FOR THIS PROJECT. THESE ITEMS HAVE BEEN USED
AS THE BASIS OF DESIGN, AND AS A CONVENIENCE IN FIXING THE MINIMUM STANDARD OF
WORKMANSHIP, FINISH AND DESIGN THAT IS REQUIRED. IF THE CONTRACTORS USES AN
“APPROVED EQUAL” ALTERNATIVE TO THE BASIS OF DESIGN, AND IF THE FEATURES OF THAT
ALTERNATIVE HAVE AN IMPACT ON OTHER COMPONENTS OF THE PROJECT, THE
CONTRACTOR SHALL INCLUDE THE NECESSARY ADJUSTMENTS IN THOSE COMPONENTS,
WHETHER FOR ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, FIRE
PROTECTION, OR ANY OTHER ELEMENTS, PLUS ANY ADJUSTMENTS FOR DIFFERENCE IN
PERFORMANCE.
2. EQUIPMENT, MATERIAL OR DEVICES SUBMITTED FOR REVIEW AS AN “EQUIVALENT” SHALL
MEET THE FOLLOWING REQUIREMENTS:
A. THE EQUIVALENT SHALL HAVE THE SAME CONSTRUCTION FEATURES SUCH AS, BUT NOT
LIMITED TO:
a. MATERIAL THICKNESS, GAUGE, WEIGHT, DENSITY, ETC.
b. WELDED, RIVETED, BOLTED, ETC., CONSTRUCTION
c. FINISH, UNDERCOATING, CORROSION PROTECTION
B. THE EQUIVALENT SHALL PERFORM WITH THE SAME OR BETTER OPERATING EFFICIENCY.
C. THE EQUIVALENT SHALL BE LOCALLY REPRESENTED BY THE MANUFACTURER FOR
SERVICE, PARTS AND TECHNICAL INFORMATION.
D. THE EQUIVALENT SHALL BEAR THE SAME LABELS OF PERFORMANCE CERTIFICATION AS
IS APPLICABLE TO THE SPECIFIED ITEM, SUCH AS UL OR NEMA LABELS OR DLC
QUALIFICATIONS.
D. DRAWINGS:
1. PROVIDE ALL MATERIALS, EQUIPMENT AND LABOR NECESSARY TO COMPLETE THE WORK
OUTLINED ON THESE CONTRACT DOCUMENTS. THE CONTRACTOR IS TO NOTE THAT THESE
DOCUMENTS ARE DIAGRAMMATIC ONLY AND THAT FINAL PLACEMENT OF EQUIPMENT OR
DEVICES IN THE FIELD MAY NOT DIRECTLY CORRESPOND TO THAT WHICH IS SHOWN ON THE
DRAWINGS. IF A CONFLICT IN POSITIONING OCCURS THE CONTRACTOR IS TO NOTIFY THE
ENGINEER IMMEDIATELY TO ASCERTAIN WHAT THE INTENT WAS BY THE DESIGN
PROFESSIONAL.
2. WHERE VARIANCES OCCUR BETWEEN THE DRAWINGS AND SPECIFICATIONS OR WITHIN
EITHER OF THE DOCUMENTS, THE ITEM OR ARRANGEMENT OF BETTER QUALITY, HIGHER
RATING, OR HIGHER VALUE SHALL BE INCLUDED IN THE CONTRACT PRICE. THE OWNER AND
ENGINEER SHALL DECIDE ON THE ITEM AND THE MANNER IN WHICH THE WORK SHALL BE
INSTALLED.
E. SURVEY AND MEASUREMENTS:
1. PRIOR TO SUBMITTING BID, VISIT SITE AND IDENTIFY EXISTING CONDITIONS AND
DIFFICULTIES THAT WILL AFFECT WORK TO BE PERFORMED. NO COMPENSATION WILL BE
GRANTED FOR ADDITIONAL WORK CAUSED BY UNFAMILIARITY WITH SITE CONDITIONS THAT
ARE VISIBLE OR READILY IDENTIFIED BY EXPERIENCED OBSERVERS. INCLUDE IN THE BID ALL
DEMOLITION WORK REQUIRED.
2. DO NOT SCALE DRAWINGS. SCALE INDICATED ON DRAWINGS IS FOR ESTABLISHING
REFERENCE POINTS ONLY. ACTUAL FIELD CONDITIONS SHALL GOVERN ALL DIMENSIONS.
3. PRIOR TO ORDERING ANY MATERIALS AND EQUIPMENT, THOROUGHLY REVIEW THE SITE
CONDITIONS TO DETERMINE IF ADEQUATE CLEARANCES AND ACCESS IS ALLOWED TO
INSTALL THE COMPONENTS. ORDER EQUIPMENT BROKEN DOWN AS NECESSARY TO
ALLOW FOR PROPER RIGGING THROUGH THE PROJECT AREA. PROVIDE ALL NECESSARY
ALTERATIONS TO THE STRUCTURE OF THE BUILDING AS NECESSARY TO RIG THE EQUIPMENT
IN PLACE.
4. ARRANGE INSTALLATION TO PROVIDE ACCESS TO EQUIPMENT FOR EASY MAINTENANCE AND
REPAIR.
F. CODES AND STANDARDS: ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE MOST
RECENTLY ADOPTED EDITIONS OF THE FOLLOWING CODES AND STANDARDS, INCLUDING ALL
JURISDICTIONAL REVISIONS:
1. STATE BUILDING CODE INCLUDING ALL SUPPLEMENTS.
2. STATE FIRE SAFETY CODE INCLUDING ALL SUPPLEMENTS.
3. STATE FIRE PREVENTION CODE INCLUDING ALL SUPPLEMENTS.
4. THE INTERNATIONAL BUILDING CODE
5. THE INTERNATIONAL EXISTING BUILDING CODE
6. THE INTERNATIONAL FIRE CODE
7. THE INTERNATIONAL MECHANICAL CODE
8. THE INTERNATIONAL PLUMBING CODE
9. THE INTERNATIONAL ENERGY CONSERVATION CODE
10. NFPA 1: FIRE CODE
11. NFPA 70: NATIONAL ELECTRICAL CODE
12. NFPA 72: NATIONAL FIRE ALARM AND SIGNALING CODE
13. NECA 1: STANDARD FOR GOOD WORKMANSHIP IN ELECTRICAL CONSTRUCTION
14. NETA ATS.
G. PERMITS AND FEES:
1. THE CONTRACTOR SHALL GIVE ALL NECESSARY NOTICES, OBTAIN ALL PERMITS; AND PAY
ALL GOVERNMENT AND STATE SALES TAXES AND FEES WHERE APPLICABLE, AND OTHER
COSTS, FILE ALL NECESSARY DRAWINGS, PREPARE ALL DOCUMENTS AND OBTAIN ALL
NECESSARY APPROVALS OF ALL GOVERNMENTAL AND STATE DEPARTMENTS HAVING
JURISDICTION, OBTAIN ALL REQUIRED CERTIFICATES OF INSPECTION FOR HIS WORK, AND
DELIVER A COPY TO THE OWNER AND ENGINEER BEFORE REQUEST FOR ACCEPTANCE AND
FINAL PAYMENT FOR THE WORK.
H. SHOP DRAWINGS:
1. PROVIDE SHOP DRAWINGS FOR ALL DEVICES SPECIFIED UNDER EQUIPMENT SPECIFICATIONS
FOR ALL SYSTEMS INCLUDING FIRE ALARM, SWITCHGEAR, CLOCK, LIGHTING, ETC., OR
WHERE CALLED FOR ELSEWHERE IN THE SPECIFICATIONS, OR WHERE SCHEDULED ON THE
DRAWINGS, OR WHERE CALLED OUT ON THE DRAWINGS. SHOP DRAWINGS SHALL INCLUDE
MANUFACTURERS’ NAMES, CATALOG NUMBERS, CUTS, DIAGRAMS, DIMENSIONS,
IDENTIFICATION OF PRODUCTS AND MATERIALS INCLUDED, COMPLIANCE WITH SPECIFIED
STANDARDS, NOTATION OF COORDINATION REQUIREMENTS, NOTATION OF DIMENSIONS
ESTABLISHED BY FIELD MEASUREMENT AND OTHER SUCH DESCRIPTIVE DATA AS MAY BE
REQUIRED TO IDENTIFY AND ACCEPT THE EQUIPMENT. A COMPLETE LIST IN EACH
CATEGORY (EXAMPLE: ALL FIXTURES) OF ALL SHOP DRAWINGS, CATALOG CUTS, MATERIAL
LISTS, ETC., SHALL BE SUBMITTED TO THE ENGINEER AT ONE TIME. NO CONSIDERATION
WILL BE GIVEN TO A PARTIAL SHOP DRAWING SUBMITTAL.
2. SHOP DRAWINGS SHALL INCLUDE EQUIPMENT SUBMITTALS, FABRICATION AND INSTALLATION
DRAWINGS, SETTING DIAGRAMS, SCHEDULES, PATTERNS, TEMPLATES AND SIMILAR
DRAWINGS. INCLUDE THE FOLLOWING INFORMATION:
A. DIMENSIONS
B. WIRING DIAGRAMS AND RISER DIAGRAMS
C. CALCULATIONS
D. IDENTIFICATION OF PRODUCTS AND MATERIALS INCLUDED.
E. COMPLIANCE WITH SPECIFIED STANDARDS AND PERFORMANCE DATA AS INDICATED.
F. NOTATION OF COORDINATION REQUIREMENTS.
G. NOTATION OF DIMENSIONS ESTABLISHED BY FIELD MEASUREMENT.
H. DO NOT USE SHOP DRAWINGS WITHOUT AN APPROPRIATE FINAL STAMP INDICATING
ACTION TAKEN IN CONNECTION WITH CONSTRUCTION.
I. DO NOT ORDER ANY MATERIALS OR EQUIPMENT PRIOR TO RECEIVING FINAL APPROVED
SHOP DRAWINGS.
3. SHOP DRAWINGS SHALL BE IN PDF/OCR FORMAT. PHOTOCOPIES ARE NOT ACCEPTABLE.
I. COORDINATION DRAWINGS:
1. PREPARE COORDINATION DRAWINGS AT A SCALE TO MATCH THE CONTRACT DOCUMENT
FLOOR PLANS; DETAILING MAJOR ELEMENTS, COMPONENTS, AND SYSTEMS OF ELECTRICAL
EQUIPMENT AND MATERIALS IN RELATIONSHIP WITH OTHER SYSTEMS, INSTALLATIONS, AND
BUILDING COMPONENTS. INDICATE LOCATIONS WHERE SPACE IS LIMITED FOR INSTALLATION
AND ACCESS AND WHERE SEQUENCING AND COORDINATION OF INSTALLATIONS ARE OF
IMPORTANCE TO THE EFFICIENT FLOW OF THE WORK, INCLUDING (BUT NOT NECESSARILY
LIMITED TO) THE FOLLOWING:
A. INDICATE THE PROPOSED LOCATIONS OF LIGHT FIXTURES, PANELBOARDS, CONDUITS,
CABINETS, ETC.
B. CLEARANCES FOR INSTALLING AND MAINTAINING INSULATION.
C. CLEARANCES FOR SERVICING AND MAINTAINING EQUIPMENT, INCLUDING NEC
REQUIREMENTS AND SPACE FOR EQUIPMENT DISASSEMBLY REQUIRED FOR PERIODIC
MAINTENANCE.
D. EQUIPMENT CONNECTIONS AND SUPPORT DETAILS.
E. EXTERIOR WALL AND FOUNDATION PENETRATIONS.
F. FIRE-RATED WALL AND FLOOR PENETRATIONS.
G. SIZES AND LOCATIONS OF REQUIRED CONCRETE PADS AND BASES.
2. INDICATE SCHEDULING, SEQUENCING, MOVEMENT, AND POSITIONING OF LARGE EQUIPMENT
INTO THE BUILDING DURING CONSTRUCTION.
3. PREPARE FLOOR PLANS, ELEVATIONS, AND DETAILS TO INDICATE PENETRATIONS IN FLOORS, WALLS, AND CEILINGS AND THEIR RELATIONSHIP TO OTHER PENETRATIONS AND
INSTALLATIONS.
4. PREPARE REFLECTED CEILING PLANS TO COORDINATE AND INTEGRATE INSTALLATIONS, AIR
OUTLETS AND INLETS, LIGHT FIXTURES, COMMUNICATION SYSTEMS COMPONENTS,
SPRINKLERS, AND OTHER CEILING-MOUNTED ITEMS.
J. AS-BUILT DRAWINGS:
1. PREPARE AS-BUILT DRAWINGS TO A SCALE TO MATCH THE CONTRACT DOCUMENT FLOOR
PLANS; DETAILING THE ACTUAL INSTALLATION OF MAJOR ELEMENTS, COMPONENTS, AND
SYSTEMS OF MECHANICAL EQUIPMENT AND MATERIALS. WHERE SHOP DRAWINGS ARE
USED, RECORD A CROSS-REFERENCE AT THE CORRESPONDING LOCATION ON THE AS-BUILT
DRAWINGS. GIVE PARTICULAR ATTENTION TO CONCEALED ELEMENTS THAT WOULD BE
DIFFICULT TO MEASURE AND RECORD AT A LATER DATE.
2. MARK NEW INFORMATION THAT IS IMPORTANT TO THE OWNER, BUT WAS NOT SHOWN ON
CONTRACT DRAWINGS OR SHOP DRAWINGS.
3. NOTE RELATED CHANGE ORDER NUMBERS WHERE APPLICABLE.
4. FINAL RECORD DOCUMENTS SHALL BE PREPARED IN THE LATEST AUTOCAD VERSION AND
DIGITAL MEDIA FOR ALL DRAWINGS AND A CLEAN SET OF REPRODUCIBLE PAPER COPIES
SHALL BE TURNED OVER TO THE OWNER AT THE COMPLETION OF THE WORK.
K. OPERATIONS AND MAINTENANCE MANUALS
1. THE CONTRACTOR SHALL PREPARE (1) PDF COPY AND (3) HARD COPIES OF A COMPLETE
MAINTENANCE AND OPERATING INSTRUCTIONS MANUAL, BOUND IN BOOKLET FORM.
ORGANIZE OPERATING AND MAINTENANCE DATA INTO SUITABLE SETS OF MANAGEABLE SIZE.
BIND PROPERLY INDEXED DATA IN INDIVIDUAL HEAVY-DUTY, 3-RING, VINYL-COVERED
BINDERS, WITH POCKET FOLDERS FOR FOLDED SHEET INFORMATION. MARK APPROPRIATE
IDENTIFICATION ON FRONT AND SPINE OF EACH BINDER.
2. MANUAL SHALL INCLUDE THE FOLLOWING:
A. DESCRIPTION OF FUNCTION, NORMAL OPERATING CHARACTERISTICS AND LIMITATIONS,
PERFORMANCE CURVES, ENGINEERING DATA AND TESTS, AND COMPLETE
NOMENCLATURE AND COMMERCIAL NUMBERS OF REPLACEMENT PARTS.
B. MANUFACTURER'S PRINTED OPERATING PROCEDURES TO INCLUDE START-UP, BREAK-IN,
AND ROUTINE AND NORMAL OPERATING INSTRUCTIONS; REGULATION, CONTROL,
STOPPING, SHUTDOWN, AND EMERGENCY INSTRUCTIONS; AND SUMMER AND WINTER
OPERATING INSTRUCTIONS.
C. MAINTENANCE PROCEDURES FOR ROUTINE PREVENTATIVE MAINTENANCE AND
TROUBLESHOOTING; DISASSEMBLY, REPAIR, AND REASSEMBLY; ALIGNING AND
ADJUSTING INSTRUCTIONS.
D. SERVICING INSTRUCTIONS AND LUBRICATION CHARTS AND SCHEDULES.
E. EMERGENCY INSTRUCTIONS.
F. SPARE PARTS LIST.
G. COPIES OF WARRANTIES.
H. WIRING DIAGRAMS.
I. RECOMMENDED "TURN AROUND" CYCLES.
J. INSPECTION PROCEDURES.
K. APPROVED SHOP DRAWINGS AND PRODUCT DATA.
L. EQUIPMENT START-UP REPORTS.
L. WARRANTIES
1. ALL EQUIPMENT PROVIDED IN THIS PROJECT SHALL CARRY A MANUFACTURER'S WARRANTY
FOR NO LESS THAN ONE (1) YEAR FROM DATE OF BENEFICIAL USE - UNLESS NOTED
OTHERWISE IN THE CONTRACT DOCUMENTS.
M. MISCELLANEOUS REQUIREMENTS:
1. THE CONTRACTOR SHALL COORDINATE ALL INTERRUPTIONS OF SERVICES AND LIMITATIONS
OF ACCESS WITH THE OWNER NO LESS THAN (5) DAYS PRIOR TO THE INTERRUPTION.
2. OBTAIN IN OWNER'S NAME WRITTEN EQUIPMENT AND MATERIAL WARRANTIES OFFERED IN
MANUFACTURER'S PUBLISHED PRODUCT DATA WITHOUT EXCLUSION OR LIMITATION.
3. GUARANTEE WORK OF THESE CONTRACT DOCUMENTS IN WRITING FOR NOT LESS THAN ONE
(1) YEAR FROM DATE OF BENEFICIAL USE. REPAIR OR REPLACE DEFECTIVE MATERIALS,
EQUIPMENT, WORKMANSHIP AND INSTALLATION THAT DEVELOP WITHIN THIS PERIOD,
PROMPT AND TO OWNER'S SATISFACTION AND CORRECT DAMAGE CAUSED IN MAKING
NECESSARY REPAIRS AND REPLACEMENTS UNDER GUARANTEE WITHIN CONTRACT PRICE.
4. SUBMIT TO THE OWNER AN OFFICIAL CERTIFICATE OF INSURANCE FOR THEIR RECORDS.
N. ELECTRICAL ACCEPTANCE TESTING
1. TESTING SHALL BE PERFORMED ON ELECTRICAL EQUIPMENT AND SYSTEMS TO ASSURE THE
EQUIPMENT AND SYSTEMS ARE OPERATIONAL AND WITHIN APPLICABLE STANDARDS AND
MANUFACTURING TOLERANCES. TESTING SHOULD VERIFY THAT EQUIPMENT AND SYSTEMS
ARE INSTALLED IN ACCORDANCE WITH DESIGN SPECIFICATIONS. ALL TESTING SHALL OCCUR
AT THE BUILDING SITE.
2. QUALIFIED TECHNICIANS WHO ARE TRAINED AND REGULARLY EMPLOYED FOR TESTING
SERVICES SHALL DO ALL THE TESTING.
3. THE TESTING ORGANIZATION SHALL CONFORM TO THE GENERAL GUIDELINES OF SECTION 5
OF THE LATEST NETA ACCEPTANCE TESTING SPECIFICATIONS. THIS INCLUDES THE
FOLLOWING:
A. SAFETY AND PRECAUTIONS
B. SUITABILITY OF TEST EQUIPMENT
C. TEST INSTRUMENT CALIBRATION.
D. TEST REPORTS
4. NOTIFY THE ARCHITECT, ENGINEER AND OWNER AT LEAST SEVEN (7) DAYS IN ADVANCE OF
ANY TESTING.
5. INSPECTION AND TESTING OF ALL APPLICABLE ELECTRICAL EQUIPMENT LISTED BELOW
SHALL BE DONE IN ACCORDANCE WITH THE LATEST VERSION OF NETA ATS.
A. SWITCHBOARDS AND SWITCHGEAR ASSEMBLIES.
B. TRANSFORMERS.
C. CABLES.
D. LOW VOLTAGE CIRCUIT BREAKERS.
E. EMERGENCY SYSTEMS - GENERATOR, AUTOMATIC TRANSFER SWITCHES,
UNINTERRUPTIBLE POWER SUPPLIES.
SECTION 26 05 19 - ELECTRICAL POWER CONDUCTORS AND CABLES
A. COORDINATION:
A. COORDINATE SIZES OF RACEWAYS, BOXES, AND EQUIPMENT ENCLOSURES INSTALLED
UNDER OTHER SECTIONS WITH THE ACTUAL CONDUCTORS TO BE INSTALLED, INCLUDING
ADJUSTMENTS FOR CONDUCTOR SIZES INCREASED FOR VOLTAGE DROP.
B. COORDINATE WITH ELECTRICAL EQUIPMENT INSTALLED UNDER OTHER SECTIONS TO
PROVIDE TERMINATIONS SUITABLE FOR USE WITH THE CONDUCTORS TO BE INSTALLED.
B. PROVIDE SINGLE CONDUCTOR BUILDING WIRE INSTALLED IN SUITABLE RACEWAY UNLESS
OTHERWISE INDICATED, PERMITTED OR REQUIRED.
C. CONDUCTOR SIZES AND AMPACITIES SHOWN ARE BASED ON COPPER.
D. MINIMUM CONDUCTOR SIZES:
A. BRANCH CIRCUITS: 12 AWG
a. 20A, 120V CIRCUITS LONGER THAN 100 FEET - #10 AWG MINIMUM AND SIZED FOR
VOLTAGE DROP.
b. 20A, 120V CIRCUITS LONGER THAN 165 FEET - #8 AWG MINIMUM AND SIZED FOR VOLTAGE
DROP.
B. CONTROL CIRCUITS: 14 AWG.
E. CONDUCTORS NO. 10 AWG AND SMALLER DIAMETER SHALL BE SOLID ANNEALED COPPER,
EXCEPT THAT CONDUCTORS FOR REMOTE CONTROL, ALARM, AND SIGNAL CIRCUITS, CLASSES 1, 2, AND 3, SHALL BE STRANDED UNLESS SPECIFICALLY INDICATED OTHERWISE.
F. CONDUCTORS NO. 8 AWG AND LARGER DIAMETER SHALL BE STRANDED ANNEALED COPPER.
G. UNDERGROUND CONDUCTORS SHALL BE TYPE XHHW-2.
H. WHERE LIGHTING FIXTURES REQUIRE 90 DEGREES C CONDUCTORS, PROVIDE ONLY
CONDUCTORS WITH 90 DEGREE C INSULATION OR BETTER.
I. MAKE ALL SPLICES IN ACCESSIBLE LOCATIONS. MAKE SPLICES IN CONDUCTORS NO. 10 AWG AND
SMALLER DIAMETER WITH INSULATED, SPRING WIRE CONNECTORS WITH PLASTIC CAPS. MAKE
SPLICES IN CONDUCTORS NO. 8 AWG AND LARGER DIAMETER WITH SOLDERLESS PRESSURE
CONNECTORS WITH INSULATING COVERS. MAKE SPLICES IN CONDUCTORS NO. 6 AND LARGER
WITH PRESSURE CONNECTORS OR SPLIT BOLT CONNECTORS.
J. MAKE WIRE TERMINATIONS USING CRIMPED TERMINALS FOR CONDUCTORS NO. 10 AND SMALLER.
MAKE WIRE TERMINATIONS FOR CONDUCTORS NO. 8 AND LARGER USING MECHANICAL OR
PRESSURE CONNECTORS. PROVIDE SUITABLE REDUCERS WHERE OVERSIZED CONDUCTORS
ARE LARGER THAN THE EQUIPMENT TERMINATION.
K. PHASE CONDUCTORS SHALL BE IDENTIFIED BY COLOR CODING. THE COLOR OF THE INSULATION ON PHASES A, B, AND C RESPECTIVELY (FOR THREE PHASE) OR PHASES A AND B RESPECTIVELY
(FOR SINGLE PHASE) OF DIFFERENT VOLTAGE SYSTEMS SHALL BE AS FOLLOWS:
A. 120/240 VOLT, SINGLE PHASE: BLACK AND RED.
L. UNLESS OTHERWISE INDICATED, THE WIRING METHOD SHALL CONSIST OF THE INSTALLATION OF
INSULATED CONDUCTORS INSTALLED IN ELECTRICAL METALLIC AND/OR WIREMOLD RACEWAY.
M. PROVIDE INSULATED, GREEN EQUIPMENT GROUNDING CONDUCTOR IN FEEDER AND BRANCH
CIRCUITS, INSTALLED IN CONDUIT OR RACEWAYS, INCLUDING LIGHTING CIRCUITS. GROUNDING
CONDUCTOR SHALL BE SEPARATE FROM ELECTRICAL SYSTEM NEUTRAL CONDUCTOR.
SECTION 26 05 26 - GROUNDING AND BONDING
A. GROUNDING SHALL BE COMPLETED IN ACCORDANCE WITH NFPA 70. GROUND EXPOSED, NON-
CURRENT-CARRYING METALLIC PARTS OF ELECTRICAL EQUIPMENT, METALLIC RACEWAY
SYSTEMS, GROUNDING CONDUCTOR IN METALLIC AND NONMETALLIC RACEWAYS, AND NEUTRAL
CONDUCTOR OF WIRING SYSTEMS. WHERE GROUND FAULT PROTECTION IS EMPLOYED, ENSURE
THAT CONNECTION OF GROUND AND NEUTRAL DOES NOT INTERFERE WITH CORRECT OPERATION
OF FAULT PROTECTION.
B. EXISTING WORK: WHERE EXISTING GROUNDING AND BONDING SYSTEM COMPONENTS ARE
INDICATED TO BE REUSED, THEY MAY BE REUSED ONLY WHERE THEY ARE FREE FROM
CORROSION, INTEGRITY AND CONTINUITY ARE VERIFIED, AND WHERE ACCEPTABLE TO THE
AUTHORITY HAVING JURISDICTION.
C. WHERE CONDUCTOR SIZE IS NOT INDICATED, SIZE TO COMPLY WITH NFPA 70.
D. USE INSULATED COPPER CONDUCTORS UNLESS OTHERWISE INDICATED. USE BARE COPPER
CONDUCTORS WHERE INSTALLED UNDERGROUND OR ENCASED IN CONCRETE.
E. USE LISTED MECHANICAL CONNECTORS, COMPRESSION CONNECTORS OR EXOTHERMIC WELDED
CONNECTIONS FOR ACCESSIBLE CONNECTIONS. USE EXOTHERMIC WELDED CONNECTIONS FOR
UNDERGROUND, CONCEALED OR OTHERWISE INACCESSIBLE CONNECTIONS.
F. GROUNDING ELECTRODE SYSTEM: PROVIDE CONNECTION TO REQUIRED AND SUPPLEMENTAL
GROUNDING ELECTRODES INDICATED TO FORM GROUNDING ELECTRODE SYSTEM. PROVIDE
CONTINUOUS GROUNDING ELECTRODE CONDUCTORS WITHOUT SPLICE OR JOINT. INSTALL
GROUNDING ELECTRODE CONDUCTORS IN RACEWAY WHERE EXPOSED OR SUBJECT TO
PHYSICAL DAMAGE. BOND GROUNDING ELECTRODE CONDUCTOR TO METALIC RACEWAY AT
EACH END WITH BONDING JUMPER.
G. SERVICE-SUPPLIED SYSTEM GROUNDING: FOR EACH SERVICE DISCONNECT, PROVIDE
GROUNDING ELECTRODE CONDUCTOR TO CONNECT NEUTRAL SERVICE CONDUCTOR TO
GROUNDING ELECTRODE SYSTEM. UNLESS OTHERWISE INDICATED, MAKE CONNECTION AT
NEUTRAL (GROUNDED) BUS IN SERVICE DISCONNECT ENCLOSURE
H. SEPARATELY DERIVED SYSTEM GROUNDING: PROVIDE GROUNDING ELECTRODE CONDUCTOR TO
CONNECT DERIVED SYSTEM GROUNDED CONDUCTOR TO NEAREST EFFECTIVELY GROUNDED
METAL BUILDING FRAME. PROVIDE SYSTEM BONDING JUMPER TO CONNECT SYSTEM GROUNDED
CONDUCTOR TO EQUIPMENT GROUNDING BUS. MAKE CONNECTION AT SAME LOCATION AS
GROUNDING ELECTRODE CONDUCTOR CONNECTION. WHERE GROUNDED METAL BUILDING
FRAME DOES NOT EXIST, BOND TO METAL WATER PIPE AT POINT OF ENTRY TO BUILDING.
SECTION 26 05 29 - HANGERS AND SUPPORTS
A. PROVIDE ALL REQUIRED HANGERS, SUPPORTS, ANCHORS, FASTENERS, FITTINGS, ACCESSORIES
AND HARDWARE NECESSARY FOR THE COMPLETE INSTALLATION OF THE ELECTRICAL WORK.
B. HANGERS AND SUPPORTS SHALL MEET ASTM STANDARDS FOR COATINGS, NECA 1 STANDARDS
FOR WORKMANSHIP, NFPA 70, AND UL 5B FOR STRUT-TYPE CHANNEL RACEWAY AND FITTINGS.
C. WHERE SUPPORT AND ATTACHMENT COMPONENT TYPES AND SIZES ARE NOT INDICATED,
SELECT IN ACCORDANCE WITH MANUFACTURER'S APPLICATION CRITERIA AS REQUIRED FOR THE
LOAD TO BE SUPPORTED.
D. STEEL COMPONENTS: USE CORROSION RESISTANT MATERIALS SUITABLE FOR THE
ENVIRONMENT WHERE INSTALLED. USE ZINC-PLATED STEEL FOR INDOOR DRY LOCATIONS. USE
GALVANIZED STEEL, STAINLESS STEEL, FIBERGLASS OR APPROVED EQUIVALENT FOR OUTDOOR, DAMP AND WET LOCATION INSTALLATIONS.
E. CONDUIT AND CABLE SUPPORTS:
A. CONDUIT STRAPS: ONE-HOLE OR TWO-HOLE, ZINC PLATED.
B. CONDUIT CLAMPS: BOLTED TYPE.
F. OUTLET BOX SUPPORTS: HANGERS AND BRACKETS SUITABLE FOR BOXES TO BE SUPPORTED.
G. METAL CHANNEL (STRUT) FRAMING SYSTEMS: FACTORY FABRICATED CONTINUOUS SLOTTED
METAL CHANNEL AND ASSOCIATED FITTINGS, ACCESSORIES, AND HARDWARE FOR FIELD-
ASSEMBLY OF SUPPORTS. ALL LOCATIONS: USE 12 GA. GALVANIZED STEEL.
H. HANGER RODS: CONTINUOUS THREADING, ZINC-PLATED STEEL.
I. USE OF POWER-ACTUATED FASTENERS REQUIRES APPROVAL OF ARCHITECT AND STRUCTURAL
ENGINEER.
J. UNLESS SPECIFICALLY INDICATED, DO NOT SUPPORT ANY ELECTRICAL COMPONENT FROM THE
ROOF DECK.
K. PLASTIC AND LEAD ANCHORS ARE NOT PERMITTED.
SECTION 26 05 33 - RACEWAY AND BOXES
A. PROVIDE A COMPLETE WIRING SYSTEM OF RACEWAYS AND BOXES LOCATED AS INDICATED ON
DRAWINGS AND AT LOCATIONS AS REQUIRED FOR SPLICES, TAPS, WIRE PULLING, EQUIPMENT
CONNECTIONS AND COMPLIANCE WITH REGULATORY REQUIREMENTS. LOCATIONS INDICATED ON
DRAWINGS ARE APPROXIMATE UNLESS DIMENSIONED.
B. STANDARDS: MATERIALS SHALL COMPLY WITH ANSI C80. NEMA AND UL REQUIREMENTS AS
APPLICABLE FOR TYPE AND MATERIAL.
C. MINIMUM CONDUIT SIZE, UNLESS OTHERWISE NOTED: INTERIOR - 3/4", EXTERIOR EXPOSED 3/4", EXTERIOR UNDERGROUND - 1".
D. CONDUIT APPLICATIONS:
A. UNDERGROUND:
a. UNDER SLAB ON GRADE - SCHEDULE 40 PVC CONDUIT WITH RIGID METAL CONDUIT
SWEEPS.
b. EXTERIOR IN TRENCH - USE SCHEDULE 40 OR SCHEDULE 80 PVC CONDUIT WITH RIGID
METAL CONDUIT SWEEPS...
c. EXTERIOR, CONCRETE ENCASED - USE TYPE EB RIGID PVC CONDUIT, TRANSITION TO
RIGID METAL WHERE EMERGING FROM UNDERGROUND.
B. EMBEDDED WITHIN SLAB: FLOOR BOX SLAB-ON-GRADE APPLICATIONS ONLY.
C. CONCEALED IN MASONRY WALLS: USE EMT WITH FLUSH MOUNTED MASONRY BOXES.
D. CONCEALED IN HOLLOW STUD WALLS: USE EMT CONDUIT OR MC CABLE (WHERE ALLOWED).
PROVIDE FLUSH SHEET-METAL BOXES.
E. INTERIOR DAMP OR WET LOCATIONS: USE RIGID METAL CONDUIT, INTERMEDIATE METAL
CONDUIT OR SCHEDULE 40 PVC CONDUIT. PROVIDE CAST METAL OR NONMETALLIC OUTLET,
JUNCTION AND PULL BOXES.
F. EXPOSED, INTERIOR DRY LOCATIONS: USE EMT CONDUIT.
G. EXPOSED FINISHED LOCATIONS: PROVIDE SURFACE METAL RACEWAY AND FITTINGS.
UNLESS SPECIFIED ON DRAWINGS, REQUIRES DESIGN TEAM APPROVAL. COORDINATE ALL
VERTICAL RUNS OF SURFACE RACEWAY WITH ARCHITECT PRIOR TO INSTALLATION.
H. CONNECTIONS TO LUMINAIRES ABOVE ACCESSIBLE CEILINGS: USE FLEXIBLE METAL
CONDUIT, MAXIMUM LENGTH OF 6 FEET.
I. CONNECTIONS TO VIBRATING EQUIPMENT: DRY LOCATIONS - USE FLEXIBLE METAL CONDUIT
OR MC CABLE; DAMP, WET OR CORROSIVE LOCATIONS - USE LIQUIDTIGHT FLEXIBLE METAL
CONDUIT; MAXIMUM LENGTH 6 FEET.
E. FITTINGS:
A. EMT - COMPLY WITH NEMA FB 1 AND UL 514B. STEEL WITH COMPRESSION FITTINGS IN DAMP
OR WET LOCATIONS, SET SCREW TYPE ELSEWHERE.
B. RIGID METAL CONDUIT - COMPLY WITH ANSI C80.1 AND UL 6. THREADED STEEL OR
MALLEABLE IRON. USE FITTING LISTED AND LABELED AS COMPLYING WITH UL 514B IN
HAZARDOUS LOCATIONS.
C. FLEXIBLE METAL CONDUIT - COMPLY WITH NEMA FB 1 AND UL 514B. USE STEEL FITTINGS.
D. LIQUIDTIGHT FLEXIBLE METAL CONDUIT - COMPLY WITH NEMA FB 1 AND UL 514B. USE STEEL
FITTINGS.
E. SURFACE METAL RACEWAY - PROVIDE FITTINGS FROM SAME MANUFACTURER AS SURFACE
RACEWAY. INCLUDE ALL REQUIRED ELBOWS, COUPLINGS MOUNTING CLIPS, COVERS, END
FITTINGS AND DEVICE MOUNTING BRACKETS.
F. BOXES: WHERE A BOX SIZE IS NOT INDICATED, SIZE TO COMPLY WITH NFPA 70, BUT NOT LESS
THAN APPLICABLE MINIMUM SIZE SPECIFIED.
A. USE SHEET METAL STEEL BOXES IN DRY LOCATIONS.
B. USE CAST IRON OR CAST ALUMINUM BOXES WITH THREADED HUBS WHERE EXPOSED RIGID
METAL CONDUIT IS USED.
C. USE NONMETALLIC BOXES WHERE EXPOSED RIGID PVC CONDUIT IS USED.
D. USE SUITABLE CONCRETE TYPE BOXES WHERE FLUSH-MOUNTED IN CONCRETE.
E. USE SUITABLE MASONRY TYPE BOXES WHERE FLUSH-MOUNTED IN MASONRY WALLS.
F. USE RAISED COVERS SUITABLE FOR TYPE OF WALL CONSTRUCTION AND DEVICE
CONFIGURATION WHERE REQUIRED.
G. USE MULTI-GANG BOXES OF SINGLE-PIECE CONSTRUCTION, DO NOT USE FIELD CONNECTED
GANGABLE BOXES.
H. MINIMUM BOX SIZE, UNLESS OTHERWISE INDICATED: WIRING DEVICE - 4 INCH SQUARE BY
1-1/2" DEEP; COMMUNICATIONS SYSTEM OUTLET 4 INCH SQUARE BY 2-1/8" DEEP.
G. CABINETS AND ENCLOSURES: COMPLY WITH NEMA 250, UL 50 AND UL 50E OR UL 508A.
A. USE NEMA TYPE 1, PAINTED STEEL FOR INDOOR CLEAN, DRY LOCATIONS.
B. USE NEMA TYPE 3R, PAINTED STEEL FOR OUTDOOR AND WET LOCATIONS.
C. PROVIDE SCREW COVER ENCLOSURES FOR PULL AND JUNCTION BOXES.
D. PROVIDE LOCKABLE, HINGE COVER TYPE FOR EQUIPMENT ENCLOSURES.
H. MECHANICAL SLEEVE SEALS: MODULAR MECHANICAL TYPE, WITH INTERLOCKING RUBBER LINKS
SHAPED TO CONTINUOUSLY FILL ANULAR SPACE BETWEEN OBJECTS AND SLEEVE, CONNECTED
WITH BOLTS AND PRESSURE PLATES TO PROVIDE A WATERTIGHT SEAL AND ELECTRICAL
INSULATION.
I. REMOVE EXPOSED ABANDONED RACEWAY, INCLUDING ABANDONED RACEWAY ABOVE
ACCESSIBLE CEILING FINISHES. CUT RACEWAY FLUSH WITH WALLS AND FLOORS, PATCH
SURFACES TO MATCH ADJACENT SURFACES.
J. DISCONNECT AND REMOVE ABANDONED OUTLETS AND DEVICES.
K. INSTALL BLANK PLATES ON ABANDONED, EMPTY BOXES.
L. EXTEND EXISTING RACEWAY AND BOX INSTALLATION USING MATERIALS AND METHODS
COMPATIBLE WITH EXISTING ELECTRICAL INSTALLATION OR AS SPECIFIED.
SECTION 26 05 53 - IDENTIFICATION FOR ELECTRICAL SYSTEMS
A. EXISTING WORK: UNLESS SPECIFICALLY EXCLUDED, IDENTIFY EXISTING ELEMENTS TO REMAIN
THAT ARE NOT ALREADY IDENTIFIED IN ACCORDANCE WITH THE SPECIFIED REQUIREMENTS.
B. SERVICE EQUIPMENT: USE IDENTIFICATION NAMEPLATE TO IDENTIFY EACH SERVICE
DISCONNECTING MEANS.
C. EMERGENCY SYSTEM EQUIPMENT; USE IDENTIFICATION NAMEPLATE OR VOLTAGE MARKER TO
IDENTIFY EMERGENCY EQUIPMENT IN ACCORDANCE WITH NFPA 70. USE IDENTIFICATION
NAMEPLATE AT EACH PIECE OF SERVICE EQUIPMENT TO IDENTIFY TYPE AND LOCATION OF ON-
SITE EMERGENCY POWER SOURCES.
D. USE IDENTIFICATION NAMEPLATES TO IDENTIFY EACH PIECE OF ELECTRICAL Distribution AND
CONTROL EQUIPMENT AND ASSOCIATED SECTIONS, COMPARTMENTS AND COMPONENTS.
IDENTIFY: NAME, AMPERE RATING, LOADS SERVED (DISCONNECT SWITCHES, ENCLOSED
CONTROLLERS, AND TRANSFORMERS ONLY), VOLTAGE AND PHASE, AND POWER
SOURCE/CIRCUIT NUMBER. INCLUDE LOCATION OF SOURCE/LOAD SERVED IF NOT WITHIN SIGHT
OF EQUIPMENT
E. PROVIDE LAMINATED ACRYLIC OR NON-CONDUCTIVE PHENOLIC WITH BEVELED EDGES.
NAMEPLATES FOR EACH EQUIPMENT ENCLOSURE, RELAY, SWITCH, AND DEVICE. NAMEPLATES
SHALL BE, 1/8” THICK, WHITE WITH BLACK CENTER CORE, MATTE FINISH SURFACE, BEVELED
EDGES, SQUARE CORNERS. ACCURATELY ALIGN LETTERING AND ENGRAVE INTO THE CORE.
MINIMUM SIZE OF NAMEPLATES SHALL BE 1” BY 2-1/2”. LETTERING SHALL BE A MINIMUM OF 1/4”
HIGH NORMAL BLOCK STYLE.
F. PROVIDE WIRE AND CABLE MARKERS OR IDENTIFICATION LABELS TO IDENTIFY CIRCUIT NUMBER
AT EACH SOURCE LOCATION; WITHIN BOXES WHERE MORE THAN ONE CIRCUIT IS PRESENT;
WITHIN EQUIPMENT ENCLOSURES WHERE CONDUCTORS ENTER AND EXIT THE ENCLOSURE; AND
IN CABLE TRAYS (MAXIMUM 20 FT. INTERVALS). PROVIDE WRAP-AROUND SELF-ADHESIVE VINYL CLOTH, WRAP-AROUND SELF-ADHESIVE VINYL SELF-LAMINATING, HEAT-SHRINK SLEEVE, PLASTIC
SLEEVE, PLASTIC CLIP-ON, OR VINYL SPLIT SLEEVE TYPE MARKERS SUITABLE FOR THE
CONDUCTOR OR CABLE TO BE IDENTIFIED.
G. PROVIDE VOLTAGE MARKERS TO IDENTIFY HIGHEST VOLTAGE PRESENT FOR ACCESSIBLE
CONDUITS (MAXIMUM 20 FT. INTERVALS).
H. PROVIDE PRE-LABELED, SNAP AROUND PIPE MARKERS ON ALL CONDUITS. MARKERS SHALL
COMPLY WITH ANSI A 13.1-1988 STANDARDS AND INDICATED VOLTAGE.
I. WARNING LABELS: USE FACTORY PRE-PRINTED OR MACHINE-PRINTED SELF-ADHESIVE
POLYESTER OR SELF-ADHESIVE VINYL LABELS; UV, CHEMICAL, WATER, HEAT AND ABRASION
RESISTANT.
J. CLEAN SURFACES TO RECEIVE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .