Drawings 515-20-102 Section 2 of 2.pdf

PDF 12 MB Posted

Attached to
Z1DA--Renovate B39-2 West Patient Privacy 515-20-102
Solicitation number
36C25021B0060
Issued by

About this file

This document provides details of a federal contract opportunity for construction services. The Department of Veterans Affairs will issue a solicitation on November 30th for a firm fixed price construction contract between $1-2 million to renovate a portion of Building 7 at the VA Medical Center in Battle Creek, Michigan to house Mental Health programs and staff. Interested service-disabled veteran-owned small businesses have until the solicitation due date, to be specified later, to submit a response. The work must be completed within 280 calendar days. All bid documents will be available for download at Contract Opportunities and interested parties should register at that site to receive notifications.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

3.7

2ND FLOOR - ORIGINAL

111'-4"

2ND FLOOR - ADDITION

112'-4"

REMOVE EXISTING MASONRY

KNEE WALL CONSTRUCTION

REMOVE EXISTING LOW WALL

FURRED CONSTRUCTION

REMOVE EXISTING DOUBLE METAL STUD

WITH GYP BD WALL CONSTRUCTION

REMOVE WALL BASE - SEE DEMO NOTES

REMOVE EXISTING FLOOR FINISH -

SEE DEMO NOTES

REMOVE EXISTING METAL STUD HEADER

REMOVE EXISTING SUSPENDED CEILING SYSTEM -

SEE DEMO NOTES

EXISTING BEAM ENCLOSURE TO REMAIN

EXISTING RAMP

EXISTING EXPANSION JOINT

EXISTING COLUMN

EXISTING ALUMINUM

CURTAIN WALL

NOTE:

CONTRACTOR TO VERIFY IN FIELD EXISTING WALL

CONSTRUCTION AND TO NOTIFY THE ARCHITECT

OF ANY MAJOR DISCREPENCIES

REMOVE EXISTING WOOD ON BEAM

ENCLOSURE ALONG ENTIRE WALL (PIER

TO PIER)

3.7

2ND FLOOR - ORIGINAL

111'-4"

2ND FLOOR - ADDITION

112'-4"

EXISTING RAMP - FEATHER OUT

SLOPE TO BE 2.86° (1:20) SLOPE

EXISTING EXPANSION JOINT

EXISTING COLUMN WITH NEW

BREAK METAL ENCLOSURE

EXISTING ALUMINUM

CURTAIN WALL

NEW EXPANSION JOINT COVER

BUILD OUT A WOOD CURB TO

MATCH OVERALL SIZE OF

EXISTING CURB

PROVIDE NEW EXPANSION JOINT COVER

WALL BASE

NEW CONCRETE LANDING

PARTITION TYPES

SEE PLAN FOR

2-HR WALL CONSTRUCTION

NEW SUSPENDED CEILING SYSTEM

NEW SUSPENDED CEILING

SYSTEM - RUN GYP. BD. UNDER

EXISTING BEAM ENCLOSURE

NEW EXPANSION JOINT COVER

SEE REFLECTED CEILING PLAN

8 1/16" ±

LEVEL

6' - 0" 6' - 2 19/128" ±

NOTE:

CONTRACTOR TO VERIFY IN FIELD EXISTING WALL

CONSTRUCTION AND TO NOTIFY THE ARCHITECT

OF ANY MAJOR DISCREPENCIES

NEW CONCRETE RAMP - 2.86° (1:20) SLOPE

PROVIDE SPRAY APPLIED FIRE PROOFING

INSIDE BEAM CAVITY. SPRAY AROUND

STEEL BEAM, ON BACK WALL, FULL HEIGHT

UP TO ROOF STRUCTURE ABOVE (FROM

PIER TO PIER) TO MAINTAIN 2HR FIRE

RATING

NEW 3/4" PARTICLE BOARD (PIER TO PIER)

architecture · engineering

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERS · SURVEYORS · CONSULTANTS ·

LANDSCAPE ARCHITECTS · LAND PLANNERS

298 VETERANS DRIVE

FOWLERVILLE,

MICHIGAN 48836

(OFFICE) 517-223-3512

(FAX) 517-223-9987

211 E. Water Street, Suite 213L

Kalamazoo, MI 49007 269.216.0222

VA STATION

Battle Creek VA Medical Center

5500 Armstrong Road

Battle Creek, MI 49037

Defining

EXCELLENCE

in the 21st Century

HEALTH

CARE

C :\R ev it\

\1

4_

A _m ic he lle .b ur ri.

rv t

5/

/2

:2 5:

A

M

39-A311

WALL SECTIONS RENOVATE B39-2 WEST

FOR PATIENT PRIVACY

BATTLE CREEK, MI

515-20-102

05/20/2021 KJH MRB/MMN

100% BID DOCUMENTS190134

3/4" = 1'-0"39-AD102

1 CONNECTOR RAMP SECTION - DEMOLITION

3/4" = 1'-0"39-A133

2 CONNECTOR RAMP SECTION - NEW (THROUGH WALL)

Revisions: Date:

65% DESIGN DEVELOPMENT 03/06/2020

RESUBMIT WITH OWNER CHANGES 10/02/2020

95% CONSTRUCTION DOCUMENTS 04/12/2021

100% BID DOCUMENTS 05/20/2021

SOLID SURFACE WALL PANEL

SEALANT

RECESSED SOLID

SURFACE SHOWER PAN

EXISTING CONCRETE SLAB

FIN. FLOOR

RECESS

EXISTING 2" DEPRESSION,

PLUMBER TO INSTALL PAN

& ADD FILLER TO ADJUST

PAN TO PROPER DEPTH AS

PER MANUFACTURER

SPECIFICATIONS

0'

1/

8"

SHOWER PAN TO BE FLUSH WITH

FINISHED FLOORING

SEE FLOOR PLANS

2.0° SLOPE (AVG.)

0'

2"

FOR PARTITION TYPE

REFER TO PLANS

NEW CONCRETE TO

INFILL REMAINDER OF 2"

DEPRESSION

5/8" TYPE 'X' HIGH IMPACT

GYP. BD. OVER Z-FURRING.

EMBED Z-FURRING IN

FIREPROOFING, PATCH

FIREPROOFING AS REQUIRED

TO MAINTAIN FIRE RATING.

EXISTING FIREPROOFED STEEL

COLUMN

EXISTING TRTD. WOOD BLOCKING

EXISTING ALUM CURTAIN

WALL

EXISTING EIFS (3"

INSULATION) ON 5/8" GLASS-

MAT GYPSUM SHEATHING ON

4" METAL STUDS

1'

4"

1' - 4"

SEALANT

0.8

F

EXISTING STEEL COLUMN

WRAPPED IN 2 LAYERS OF 5/8"

TYPE 'X' HIGH IMPACT GYP. BD.

EXISTING ALUM.

CURTAIN WALL

MTL COLUMN COVER,

COLOR TO MATCH

EXISTING CURTAINWALL -

BONE WHITE

3/

4"

9 3/4" ±

3.7

A.9

5/8" TYPE 'X' HIGH

IMPACT GYP. BD.

EXIST STEEL COLUMN

EXISTING TRTD. WOOD BLOCKING

EXISTING ALUM CURTAIN

WALL

EXISTING EIFS ON 2 1/2"

DENSGLASS 8" MTL STUD

AND 5/8" GYP. BD.

A

REMOVE EXISTING SPRAY APPLIED FIRE

PROOFING AND SHEATHING AS REQ'D FOR

NEW WORK

EXIST TYP MTL STUD, TYP.

TREATED WOOD BLOCKING

PARTITION TYPES

SEE PLAN FOR

P A

R T

IT

IO

N T

Y P

E S

S E

E P

LA

N

F O

R

5/8" TYPE 'X' HIGH

IMPACT GYP. BD. OVER

1 5/8" METAL STUD

EXISTING STEEL COLUMN

ADJUSTABLE METAL CORNER

BEAD, TYP.

ADJUSTABLE METAL CORNER

BEAD, TYP.

P A

R T

IT

IO

N T

Y P

E S

S E

E P

LA

N

F O

R

REMOVE EXISTING SPRAY

APPLIED FIRE PROOFING AS

REQ'D FOR NEW WORK

I

SEAMLESS ACOUSTICAL

CEILING SYSTEM

WALL CONSTRUCTION,

REFER TO FLOOR PLAN

FOR PARTITION TYPE

GYPSUM BOARD CEILING SYSTEM

METAL CORNER BEAD, TYP.

SEE REFLECTED

CEILING PLAN

SEAMLESS ACOUSTICAL

CEILING SYSTEM

SEE REFLECTED

CEILING PLAN

SEE REFLECTED

CEILING PLAN

SEE REFLECTED

CEILING PLAN

METAL CORNER BEAD, TYP.

SEE REFLECTED

CEILING PLAN

SEAMLESS ACOUSTICAL

CEILING SYSTEM

SEAMLESS ACOUSTICAL

CEILING SYSTEM

SEAMLESS ACOUSTICAL

CEILING SYSTEM

GYPSUM BOARD

CEILING SYSTEM

CEILING PLAN

VARES- SEE REFLECTED METAL CORNER BEAD, TYP.

EXIST LT. GA. METAL BOX

HEADER

EXIST 2X WD NAILER

5/8" TYPE 'X' HIGH IMPACT

GYP. BD.

METAL CORNER BEAD

TRIM

GYP. BD. JAMB BEYOND

EXIST ALUMINUM WINDOW

EXISTING EXTERIOR WALL

CONSTRUCTION. EIFS/ BRICK

5/8" TYPE 'X' HIGH IMPACT

GYP. BD.

EXIST DOUBLE METAL

STUD @ EA. JAMB

EXIST 2X WD NAILER

SOLID SURFACE SILL BELOW

EXIST ALUMINUM WINDOW

5/8" TYPE 'X' HIGH

IMPACT GYP. BD.

5/8" TYPE 'X' HIGH

IMPACT GYP. BD.

METAL CORNER BEAD

TRIM

EXISTING EXTERIOR WALL

CONSTRUCTION. EIFS/ BRICK

EXIST ALUMINUM WINDOW

SOLID SURFACE SILL

EXIST 2X WD NAILER

3"

5/8" TYPE 'X' HIGH

IMPACT GYP. BD.

EXISTING EXTERIOR WALL

CONSTRUCTION. EIFS/ BRICK

SEALANT

GYP. BD. JAMB BEYOND

5/8" TYPE 'X' HIGH

IMPACT GYP. BD. EXIST STEEL COLUMN

EXISTING TRTD. WOOD BLOCKING

EXISTING ALUM CURTAIN

WALL

EXISTING EIFS ON 2 1/2"

DENSGLASS 8" MTL STUD

AND 5/8" GYP.

EXIST 5/8" GYP. BD.

METAL CORNER BEAD

1.8

A

MTL STUDS @ 48" O.C. MAX.

FACE OF WALL

MTL STUDS @ 16" O.C. MAX.

WOOD SHIM - SCRIBE TO FIT (TYP.)

CASEWORK TYP. - REFER TO

CASEWORK DETAILS

1"

UNLESS

SHOWN

OTHERWISE

SEE REFLECTED

CEILING PLAN

PLAM FACED WOOD

STOP - SCRIBE TO FIT

(TYP.)

GYP. BD.

1' - 1"

6"

SEAMLESS ACOUSTICAL

CEILING SYSTEM

SEE REFLECTED

CEILING PLAN

1/4" SOLID SURFACE

MATERIAL (SSM-2) TYP.

EASED EDGE, TYP. ALL

EXPOSED EDGES

3 3/4" 3 3/4"

1' - 1 1/2"

1/

2"

1/ 2"

7"

39-A501

39-A501

INSIDE OF BOX BEHIND

SOLID SURFACE MATERIAL

3/ 8"

4" 3/

8"

TAMPER RESISTANT

FASTENER, TYP

1/

2" 4"

1/

2"

4"

2x WOOD BLOCKING

1/4" SOLID SURFACE

MATERIAL (SSM-2) TYP.

EASED EDGE, TYP. ALL

EXPOSED EDGES

2x WOOD BLOCKING

TAMPER RESISTANT FASTENER, TYP

PARTITION TYPES

SEE PLAN FOR

1 1/2"10 1/2"1 1/2"

4"

1/4" SOLID SURFACE

MATERIAL (SSM-2) TYP.

EASED EDGE, TYP. ALL

EXPOSED EDGES

2x WOOD BLOCKING

BELOW BOX

2 1/4" 6" 2 1/4"

P A

R T

IT

IO

N T

Y P

E S

S E

E P

LA

N

F O

R

2'

0"

1' - 6"

6" 4"

WOOD SIDE PANEL

WOOD CABINET

BULKHEAD, TYP. SEE TYP.

BULKHEAD DETAIL AT

CASEWORK

WOOD SHIM -

SCRIBE TO FIT (TYP.)

PLAM FACED WOOD STOP -

SCRIBE TO FIT (TYP.)

ELECTRICAL

OUTLET, TYP.

1/ 4"

WALL CONSTRUCTION,

REFER TO PLANS FOR

SPECIFIC PARTITION TYPE.

5/8" TYPE 'X' HIGH IMPACT

GYP. BD.

J BEAD, TYP.

CAULK, ENTIRE PERIMETER

FLOORING, TYP

1/4"

RIGID WALL PROTECTION,

SEE FINISH SCHEDULE

5/8" TYPE 'X' HIGH IMPACT

GYP. BD. OVER EXIST. STUDS.

PATCH FIREPROOFING AS

REQUIRED TO MAINTAIN FIRE

RATING.

EXISTING ALUM CURTAIN

WALL

EXISTING EIFS (3"

INSULATION) ON 5/8" GLASS-

MAT GYPSUM SHEATHING ON

4" METAL STUDS

SEALANT

GYP. BD. & METAL STUD

PARTITION - SEE PARTITION

TYPES

REMOVE FIN TUBE - SEE

MECHANICAL

REMOVE EXISTING SOLID

SURFACE CORNER GUARD

REMOVE WALL BASE - SEE DEMO NOTES

REMOVE EXISTING FLOOR FINISH -

SEE DEMO NOTES

NOTE:

CONTRACTOR TO VERIFY IN FIELD EXISTING WALL

CONSTRUCTION AND TO NOTIFY THE ARCHITECT

OF ANY MAJOR DISCREPENCIES

REMOVE EXISTING SOLID

SURFACE SILL

REMOVE TOP LAYER OF GYPSUM

BOARD

EXISTING WALL BEYOND TO

REMAIN

EXISTING WINDOW

SYSTEM TO REMAIN

EXISTING SOLID

SURFACE TRIM TO

REMAIN

EXISTING WALL

CONSTRUCTION TO REMAIN

EXISTING FLOOR SLAB

TO REMAIN

NOTE:

CONTRACTOR TO VERIFY IN FIELD EXISTING WALL

CONSTRUCTION AND TO NOTIFY THE ARCHITECT

OF ANY MAJOR DISCREPENCIES

FIN TUBE & LOUVERS - SEE

MECHANICAL DRAWINGS

CONCRETE RAMP

1/2" SOLID SURFACE SILL

SOLID SURFACE CORNER

GUARD BEYOND, MATCH

EXISTING COLOR AND SIZE

EXISTING WINDOW

SYSTEM TO REMAIN

EXISTING WALL

CONSTRUCTION TO REMAIN

EXISTING FLOOR SLAB

TO REMAIN

EXISTING SOLID

SURFACE TRIM TO

REMAIN

SEALANT

4"

2 1/2" METAL STUD

HIGH IMPACT GYP. BD.

architecture · engineering

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERS · SURVEYORS · CONSULTANTS ·

LANDSCAPE ARCHITECTS · LAND PLANNERS

298 VETERANS DRIVE

FOWLERVILLE,

MICHIGAN 48836

(OFFICE) 517-223-3512

(FAX) 517-223-9987

211 E. Water Street, Suite 213L

Kalamazoo, MI 49007 269.216.0222

VA STATION

Battle Creek VA Medical Center

5500 Armstrong Road

Battle Creek, MI 49037

Defining

EXCELLENCE

in the 21st Century

HEALTH

CARE

C :\R ev it\

\1

4_

A _m ic he lle .b ur ri.

rv t

5/

/2

:2 6:

A

M

39-A501

ARCHITECTURAL DETAILS RENOVATE B39-2 WEST

FOR PATIENT PRIVACY

BATTLE CREEK, MI

515-20-102

05/20/2021 KJH MRB/MMN

100% BID DOCUMENTS190134

3" = 1'-0"39-A132

16 SHOWER PAN DETAIL

1" = 1'-0"39-A102

3 COLUMN PLAN DETAIL

1 1/2" = 1'-0"39-A102

5 COLUMN PLAN DETAIL

1 1/2" = 1'-0"39-A102

8 A/2 COLUMN PLAN DETAIL (K/2 OPP.)

1 1/2" = 1'-0"39-A132

4 COLUMN PLAN DETAIL

1 1/2" = 1'-0"39-A112

10 CEILING BULKHEAD DETAIL

1 1/2" = 1'-0"39-A112

9 CEILING BULKHEAD DETAIL

1 1/2" = 1'-0"39-A102

12 WINDOW HEAD DETAIL AT EXISTING EXTERIOR WALL

1 1/2" = 1'-0"39-A102

7 WINDOW JAMB DETAIL AT EXISTING EXTERIOR WALL

1 1/2" = 1'-0"39-A102

1 WINDOW SILL DETAIL AT EXISTING EXTERIOR WALL

1 1/2" = 1'-0"39-A102

2 A/1.8 COLUMN PLAN DETAIL (K/1.8 OPP.)

1 1/2" = 1'-0"

11 TYPICAL BULKHEAD DETAIL AT CASEWORK

3" = 1'-0"39-I203

17 PAPER TOWEL DISPENSER - FRONT

3" = 1'-0"39-A501

18 PAPER TOWEL DISPENSER - SECTION

3" = 1'-0"39-A501

19 PAPER TOWEL DISPENSER - PLAN

1" = 1'-0"

6 MICROWAVE CABINET DETAIL

12" = 1'-0"39-I203

13 TOILET ROOM TYP. WALL TO FLOOR TRANSITION

1 1/2" = 1'-0"39-A132

20 STOREFRONT END PLAN DETAIL

1 1/2" = 1'-0"39-A133

14 RADIANT HEAT ENCLOSURE DEMOLITION

1 1/2" = 1'-0"39-A133

15 RADIANT HEAT ENCLOSURE NEW

Revisions: Date:

65% DESIGN DEVELOPMENT 03/06/2020

RESUBMIT WITH OWNER CHANGES 10/02/2020

10"

4 1/4" 1"

4 3/4"

/2

1"

A C

R Y

L

IC

G L

A Z

IN

G

R E

C E

S S

E D

1"

SOLID SURFACE COUNTERTOP

ON WD SUBSTRATE

1/2" RADIUS, BOTH SIDES

SEALANT, BOTH SIDES

METAL ANGLE, SECURED TO TOP

OF 2X WD BLOCKING, PROVIDE

CONTINUOUS PRESSURE TO

SECURE ACRYLIC GLAZING

2X WD BLOCKING

NEOPRENE SEAL, TYP. BETWEEN

METAL ANGLE AND ACRYLIC

GLAZING

RIGID WALL PROTECTION OVER

1/2" WD SUBSTRATE

1/2" x 4" HORIZONTAL RIGID WALL

PROTECTION TRIM TYP.

3/8" x 4" VERTICAL RIGID WALL

PROTECTION TRIM, TYP. BEYOND

RIGID WALL PROTECTION

OVER 3/4" WD SUBSTRATE

RIGID WALL PROTECTION

OVER 1/2" WD SUBSTRATE

1/4" RESIN PANEL

1/2" CLEAR CAST ACRYLIC SHEET

GLAZING

GROMMET

10"

4 1/4" 1"

4 3/4"

/2

1"

A C

R Y

L

IC

G L

A Z

IN

G

R E

C E

S S

E D

1"

SOLID SURFACE COUNTERTOP ON

WD SUBSTRATE

1/2" RADIUS, BOTH SIDES

SEALANT, BOTH SIDES

METAL ANGLE, SECURED TO TOP OF

2X WD BLOCKING, PROVIDE

CONTINUOUS PRESSURE TO SECURE

ACRYLIC GLAZING

2X WD BLOCKING

NEOPRENE SEAL, TYP. BETWEEN

METAL ANGLE AND ACRYLIC GLAZING

RIGID WALL PROTECTION OVER 1/2"

WD SUBSTRATE

1/2" x 4" HORIZONTAL RIGID WALL

PROTECTION TRIM TYP.

3/8" x 4" VERTICAL RIGID WALL

PROTECTION TRIM, TYP. BEYOND

RIGID WALL PROTECTION

OVER 3/4" WD SUBSTRATE

RIGID WALL PROTECTION

OVER 1/2" WD SUBSTRATE

1/2" CLEAR CAST ACRYLIC SHEET

GLAZING

3/4" WD SUBSTRATE

7"

4" 4"

E Q

4"

E Q

4"

E Q

1/ 2"

1/2" CLEAR CAST ACRYLIC

SHEET GLAZING

10" 24"

/2

GROMMET

SOLID SURFACE

COUNERTOP ON

WD SUBSTRATE

COUNTERTOP SUPPORT

BRACKET

CUT-OUT FOR

ELECTRICAL CONDUIT

RIGID WALL PROTECTION OVER

3/4" WD SUBSTRATE

BASE

39-A502

RIDGID WALL PROTECTION OVER

1/2" WD SUBSTRATE

1/2" x 4" HORIZONTAL RIGID WALL

PROTECTION TRIM TYP.

3/8" x 4" VERTICAL RIGID WALL

PROTECTION TRIM, TYP. BEYOND

1/4" RESIN PANEL

RIDGID WALL PROTECTION OVER

1/4" WD SUBSTRATE

3/4" SUBSRATE

1"1"

FINISHED FLOOR

7"

/2

/2

1/2" CLEAR CAST ACRYLIC

SHEET GLAZING

10" 24"

/2

GROMMET

SOLID SURFACE

COUNERTOP ON

WD SUBSTRATE

COUNTERTOP SUPPORT

BRACKET

CUT-OUT FOR ELECTRICAL

CONDUIT

RIGID WALL PROTECTION OVER

3/4" WD SUBSTRATE

BASE

39-A502

1/2" x 4" HORIZONTAL RIGID

WALL PROTECTION TRIM TYP.

3/8" x 4" VERTICAL RIGID WALL

PROTECTION TRIM, TYP. BEYOND

RIDGID WALL PROTECTION

OVER 1/2" WD SUBSTRATE

3/4" SUBSRATE

1"1"

FINISHED FLOOR

7"

4" 4"

E Q

4"

E Q

4"

E Q

1/ 2"

1/2" CLEAR CAST ACRYLIC

SHEET GLAZING

10"

/2

EXISTING SOLID SURFACE

COUNERTOP MODIFIED TO

FIT NEW DESK LAYOUT

EXISTING COUNTERTOP SUPPORT

BRACKET

MODIFY EXISTING VERTICAL

SUPPORTS AS REQUIRED FOR NEW

DESK DESIGN

BASE

39-A502

RIGID WALL PROTECTION OVER

1/2" WD SUBSTRATE

1/2" x 4" HORIZONTAL RIGID WALL

PROTECTION TRIM TYP.

3/8" x 4" VERTICAL RIGID WALL

PROTECTION TRIM, TYP. BEYOND

1/4" RESIN PANEL

RIGID WALL PROTECTION OVER

1/4" WD SUBSTRATE

3/4" SUBSRATE

1"1"

FINISHED FLOOR

SIM

EXISTING DESK CONSTRUCTION TO

REMAIN, CONTRACTOR TO VERIFY

IN FIELD ACTUAL CONSTRUCTION

EXISTING 2x6 BOTTOM PLAE, MODIFY

AS REQ'D FOR NEW DESK DESIGN

EXISTING BASE CABINET TO BE

RELOCATED AS SHOWN IN ELEVATION

FINISH ENDS TO MATCH

SOLID SURFACE COUNERTOP

ON WD SUBSTRATE

RIGID WALL PROTECTION

OVER 3/4" WD SUBSTRATE

BASE

FINISHED FLOOR

5"

SOLID SURFACE COUNTERTOP

ON WD SUBSTRATE

1/2" RADIUS, BOTH SIDES

7"

1" 1"

/2

7"

/2

/2

1/2" CLEAR CAST ACRYLIC

SHEET GLAZING

10"

/2

"SOLID SURFACE

COUNERTOP ON

WD SUBSTRATE

CUT-OUT FOR ELECTRICAL

CONDUIT

BASE

1/2" x 4" HORIZONTAL RIGID WALL

PROTECTION TRIM TYP.

3/8" x 4" VERTICAL RIGID WALL

PROTECTION TRIM, TYP. BEYOND

RIGID WALL PROTECTION OVER

1/2" WD SUBSTRATE

3/4" SUBSRATE

1"1"

FINISHED FLOOR

BASE CABINET -

HARDWOOD VENEERED

PLYWOOD, BOX/ BOX/

FILE DRAWERS

WALL BASE

1"

25"

7"

4" 4"

E Q

4"

E Q

4"

E Q

1/ 2"

1/2" CLEAR CAST ACRYLIC

SHEET GLAZING

10"

RIDGID WALL PROTECTION OVER

1/2" WD SUBSTRATE

1/2" x 4" HORIZONTAL RIGID

WALL PROTECTION TRIM TYP.

3/8" x 4" VERTICAL RIGID WALL

PROTECTION TRIM, TYP. BEYOND

1/4" RESIN PANEL

RIDGID WALL PROTECTION OVER

1/4" WD SUBSTRATE

3/4" SUBSRATE

1"1"

FINISHED FLOOR

SOLID SURFACE

COUNERTOP ON

WD SUBSTRATE

BASE CABINET -

HARDWOOD VENEERED

PLYWOOD, BOX/ BOX/

FILE DRAWERS

WALL BASE

0"24"

/2

25"

7"

/4

FINISHED WALL

ANCHOR METAL STUD TO EXISTING

COLUMN OR NEW WD BLOCKING

RIGID WALL PROTECTION OVER 3/4" WD

SUBSTRATE, TYP.

DOUBLE METAL STUD @ JAMB - 550S200-68 (GRADE 33)

DOOR SEE DOOR SCHEDULE

1 x 2 WOOD STOP, COORDINATE LOCATION

WITH DOOR AND DOOR HARDWARE

1" WD SUBSTRATE

7"

RIGID WALL PROTECTION OVER 3/4"

WD SUBSTRATE, TYP.

DOUBLE METAL STUD @ JAMB - 550S200-68 (GRADE 33)

DOOR SEE DOOR SCHEDULE

1 x 2 WOOD STOP, COORDINATE

LOCATION WITH DOOR AND DOOR

HARDWARE

SIMPSON STRONG TIE RCKW5.5 W/ STIFFENER;

FASTEN TO STUD W/ (10) #12 SCREWS - PATTERN 4B

(2) 3/8" DIA. A193, GR B7 ANCHOR ROD; ADHESIVE

ANCHORED W/ SIMPSON STRONG TIE SET-3G AND 2

3/4" MIN. EFFECTIVE EMBDMENT

9"

1" 7"

1"

CONTINUOUS SILICONE SEALANT - ALL VERTICAL EDGES

SOLID SURFACE COUNTERTOP OVER WD SUBSTRATE

EDGE OF DESK BELOW

1/2" CLEAR CAST ACRYLIC SHEET GLAZING10"

7"

RIGID WALL PROTECTION OVER 3/4"

WD SUBSTRATE, TYP.

DOUBLE METAL STUD @ JAMB - 550S200-68 (GRADE 33)

DOOR SEE DOOR SCHEDULE

1 x 2 WOOD STOP, COORDINATE

LOCATION WITH DOOR AND DOOR

HARDWARE

SIMPSON STRONG TIE RCKW5.5 W/ STIFFENER;

FASTEN TO STUD W/ (10) #12 SCREWS - PATTERN 4B

(2) 3/8" DIA. A193, GR B7 ANCHOR ROD; ADHESIVE

ANCHORED W/ SIMPSON STRONG TIE SET-3G AND 2

3/4" MIN. EFFECTIVE EMBDMENT

9"

1" 7"

1"

10"

3/8" x 4" VERTICAL RIGID WALL

PROTECTION TRIM, TYP.

1" WD SUBSTRATE

DOOR SEE DOOR SCHEDULE

1 x 2 WOOD STOP, COORDINATE

LOCATION WITH DOOR AND DOOR

HARDWARE

7"

V.I.F

VARIES

SEALANT, ALONG ENTIRE TOP EDGE

SEALANT

CONTRACTOR TO VERIFY OVERALL HEAD

HEIGHT. SECURE HEAD TO BULKHEAD

FRAMING FOR STABILIZATION

METAL STUD BRACING @ 48" O.C.

EXISTING BULKHEAD - CONTRACTOR TO

VERIFY IN FIELD HEIGHT

2 1/2" METAL STUD

JAMB BEYOND

DOUBLE METAL STUD BOX HEADER -

550S162

5 1/2" METAL STUD

DOOR SEE DOOR SCHEDULE

1 x 2 WOOD STOP, COORDINATE LOCATION

WITH DOOR AND DOOR HARDWARE

SIMPSON STRONG TIE RCKW5.5 W/ STIFFENER;

FASTEN TO STUD W/ (10) #12 SCREWS - PATTERN 4B

(2) 3/8" DIA. A193, GR B7 ANCHOR ROD; ADHESIVE

ANCHORED W/ SIMPSON STRONG TIE SET-3G AND 2

3/4" MIN. EFFECTIVE EMBDMENT

7"

V A

R

IE

S S

E E

P

LA

N 7"

RIGID WALL PROTECTION OVER 3/4"

WD SUBSTRATE, TYP.

DOUBLE METAL STUD @ JAMB - 550S200-68 (GRADE 33)

7"

5 1/2" METAL STUD

DOUBLE METAL STUD @ JAMB - 550S200-68 (GRADE 33)

DOOR SEE DOOR SCHEDULE

1 x 2 WOOD STOP, COORDINATE

LOCATION WITH DOOR AND DOOR

HARDWARE

SIMPSON STRONG TIE RCKW5.5 W/

STIFFENER; FASTEN TO STUD W/

(10) #12 SCREWS - PATTERN 4B

EXISTING CONSTRUCTION TO

REMAIN, MODIFY AS REQUIRED

FOR NEW DESK DESIGN7"

7"

SOLID SURFACE

COUNTERTOP ABOVE

1 x 4 HARDWOOD TRIM, TYP.

7"

(2) 3/8" DIA. A193, GR B7 ANCHOR ROD; ADHESIVE

ANCHORED W/ SIMPSON STRONG TIE SET-3G AND 2

3/4" MIN. EFFECTIVE EMBDMENT

V A

R

IE

S

PLAM ON 3/4" SUBSTRATE

DOOR SEE DOOR SCHEDULE

1 x 2 WOOD STOP, COORDINATE

LOCATION WITH DOOR AND DOOR

HARDWARE

VARIES 7"

SEALANT, ALONG ENTIRE

TOP EDGE, BOTH SIDES

EXISTING BULKHEAD - CONTRACTOR TO

VERIFY OVERALL HEAD HEIGHT.

SECURE HEAD TO BULKHEAD FRAMING

FOR STABILIZATION

JAMB BEYOND

DOUBLE METAL STUD BOX HEADER -

550S162

V A

R

IE

S architecture · engineering

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERS · SURVEYORS · CONSULTANTS ·

LANDSCAPE ARCHITECTS · LAND PLANNERS

298 VETERANS DRIVE

FOWLERVILLE,

MICHIGAN 48836

(OFFICE) 517-223-3512

(FAX) 517-223-9987

211 E. Water Street, Suite 213L

Kalamazoo, MI 49007 269.216.0222

VA STATION

Battle Creek VA Medical Center

5500 Armstrong Road

Battle Creek, MI 49037

Defining

EXCELLENCE

in the 21st Century

HEALTH

CARE

C :\R ev it\

\1

4_

A _m ic he lle .b ur ri.

rv t

5/

/2

:2 6:

A

M

39-A502

NURSE STATION DETAILS RENOVATE B39-2 WEST

FOR PATIENT PRIVACY

BATTLE CREEK, MI

515-20-102

05/20/2021 KJH MRB/MMN

100% BID DOCUMENTS190134

3" = 1'-0"39-A502

5 ENLARGED DESK DETAIL 1W & 2W

3" = 1'-0"39-A502

6 ENLARGED DESK DETAIL 1 N/S & 2N/S

1" = 1'-0"39-A131

1 2 W NURSE STATION

1" = 1'-0"39-A130

2 1 N/S & 2 N/S NURSE STATION

1" = 1'-0"39-A131

3 1 W NURSE STATION

1 1/2" = 1'-0"39-A130

4 NURSE STATION END WALL

1" = 1'-0"39-I202

7 1 N/S & 2 N/S NURSE STATION FILE

1" = 1'-0"39-A131

8 2 W NURSE STATION FILE

1 1/2" = 1'-0"39-A130

9 1 N/S, 2 N/S, 1 W NURSE STATION - DOOR JAMB

1 1/2" = 1'-0"39-A130

10 1 N/S & 2 N/S NURSE STATION - DOOR JAMB HIGH

1 1/2" = 1'-0"39-A130

12 1 N/S & 2 N/S NURSE STATION - DOOR JAMB LOW

1 1/2" = 1'-0"39-A130

13 1 N/S & 2 N/S NURSE STATION - DOOR HEAD 1

1 1/2" = 1'-0"39-A130

14 1 N/S & 2 N/S NURSE STATION - DOOR JAMB1 1/2" = 1'-0"39-A131

15 1 W NURSE STATION - JAMB

1 1/2" = 1'-0"39-A130

11 1 N/S & 2 N/S NURSE STATION - DOOR HEAD 2

Revisions: Date:

EXISTING T.V. CABINET TO BE RELOCATED. MODIFY AS REQ'D

FOR NEW LOCATION AND ADDITION OF THE FIREPLACE. SECURE

TO WALL WITH CONCEALED SECURITY FASTENERS, BRACKETS,

AND ANCHORS. REFER TO DETAILS ON THIS SHEET FOR

ADDITIONAL INFORMATION ON MODIFICATIONS REQUIRED.

PROVIDE NEW END PANEL,

TYP. BOTH SIDES. MATCH

EXISTING MATERIAL AND

STAIN

REMOVE METAL WIRE MESH

REMOVE SOLID INFILL

FOR INSTALLATION OF

NEW WIRE MESH, BOTH

SIDES

CONTRACTOR TO VERIFY

MATERIAL BEHIND FLAT

SCREEN TV.

39-A503

Sim

NOTE: CONTRACTOR TO MATCH THE DESIGN INTENT OF THE EXISTING T.V. CABINET IN

2 SOUTH, DAY ROOM 245. ALL DIMENSIONS SHOWN ARE FOR REFERENCE ONLY.

CONTRACTOR IS RESPONSIBLE TO IDENTIFY AND VERIFY ALL DIMENSIONS REQUIRED

TO DUPLICATE CABINET.

56"

9" 37 1/2" 9"

1/

2"

/4

3/ 4"

5" 5"

/2

62"

39-A503

39-A503

METAL MESH TO

MATCH EXISTING

WOOD BASE, ALL SIDES,

MATCH EXISTING MATERIAL

AND FINISH

E Q

E Q

ACRYLIC SHEET, ANTI-GLARE,

IN FRONT OF FIREPLACE

INSERT

2x HARD WOOD LUMBER TO

MATCH EXISTING MATERIAL

AND FINISH

39-A503

AT DAY ROOM 245

REPLACE MESH COVER ON

EXISTING TV VOLUME BUMPOUT

TO MATCH NEW MESH BELOW, DO

NOT ROUTE HOLES INTO MESH.

AT DAY ROOM 208

PROVIDE METAL MESH TO MATCH

EXISTING

ELECTRICAL OUTLET & TV

SERVICE CONNECTION

METAL MESH TO

MATCH EXISTING

AIR CIRCULATION AND

SOUND TRANSMISSION

BOX

CROWN MOLDING TO

MATCH EXISTING

ACRYLIC SHEET,

ANTI-GLARE

CROWN MOLDING TO

MATCH EXISTING

FIREPLACE INSERT. BASIS OF

DESIGN DIMPLEX "OPTI-V

SOLO BUILT IN FIREPLACE,

MODEL VF2927L"

9 1/2"

7"

T.V. CAVITY

ACRYLIC SHEET, ANTI-GLARE

NOTE: CONTRACTOR TO MATCH THE DESIGN INTENT OF THE EXISTING T.V. CABINET IN

2 SOUTH, DAY ROOM 245. ALL DIMENSIONS SHOWN ARE FOR REFERENCE ONLY.

CONTRACTOR IS RESPONSIBLE TO IDENTIFY AND VERIFY ALL DIMENSIONS REQUIRED

TO DUPLICATE CABINET.

39-A503

/4

ACRYLIC SHEET, ANTI-GLARE

ATTACH TO ROUTED WOOD, TYP.

MUST BE ABLE TO REMOVE

ACRYLIC AND TRIM UNIT TO

ALLOW MAINTENANCE TO

FIREPLACE BEYOND. SECURE

WITH TAMPER RESISTANT

SCREWS

FINISHED FACE PLYWOOD,

PAINTED BLACK, TYP.

2x HARDWOOD LUMBER TRIM

MATCH EXISTING CONSTRUCTION

AND FINISH, TYP.

WOOD TRIM BASE, MATCH

EXISTING CONSTRUCTION AND

FINISH

FINISHED FACE PLYWOOD,

PAINTED BLACK, TYP.

2x WOOD BLOCKING

METAL STUD & GYP. BD.

PARTITION - SEE

PARTITION TYPES

2x WOOD BLOCKING

1" 1"

5/8"

1' - 1 3/4"

1 3/8"

FIREPLACE INSERT.

BASIS OF DESIGN

DIMPLEX "OPTI-V SOLO

BUILT IN FIREPLACE,

MODEL VF2927L"

39-A503

ALIGN

FINISHED FACE PLYWOOD,

PAINTED BLACK, TYP.

WOOD TRIM BASE, MATCH

EXISTING CONSTRUCTION

AND FINISH

METAL STUD & GYP. BD.

PARTITION - SEE

PARTITION TYPES

BLACK METAL MESH

FIREPLACE INSERT. BASIS

OF DESIGN DIMPLEX "OPTI-V

SOLO BUILT IN FIREPLACE,

MODEL VF2927L"

ACRYLIC SHEET, ANTI-

GLARE ATTACH TO ROUTED

WOOD, TYP.

EQ EQ

1/

2"

10" 3' - 0 1/2" 10"

1/

2"

1/

4" 1'

1"

3/

8"

NOTE: CONTRACTOR TO MATCH THE DESIGN INTENT OF THE EXISTING T.V. CABINET IN

2 SOUTH, DAY ROOM 245. ALL DIMENSIONS SHOWN ARE FOR REFERENCE ONLY.

CONTRACTOR IS RESPONSIBLE TO IDENTIFY AND VERIFY ALL DIMENSIONS REQUIRED

TO DUPLICATE CABINET.

39-A503

ALIGN

FINISHED FACE PLYWOOD,

PAINTED BLACK, TYP.

WOOD TRIM, MATCH

EXISTING CONSTRUCTION

AND FINISH

METAL STUD & GYP. BD.

PARTITION - SEE

PARTITION TYPES

ACRYLIC SHEET, ANTI-

GLARE ATTACH TO ROUTED

WOOD, TYP.

EQ EQ

3/

8"

3" 4' - 8" 3"

3/

8"

NOTE: CONTRACTOR TO MATCH THE DESIGN INTENT OF THE EXISTING T.V. CABINET IN

2 SOUTH, DAY ROOM 245. ALL DIMENSIONS SHOWN ARE FOR REFERENCE ONLY.

CONTRACTOR IS RESPONSIBLE TO IDENTIFY AND VERIFY ALL DIMENSIONS REQUIRED

TO DUPLICATE CABINET.

ALIGN

ROLL-UP DOOR -

SEE SCHEDULE

METAL GUIDE

5/8" GYPSUM BOARD

ON METAL STUD

FRAMING

5/8" 6" 5/8"

ROLL-UP DOOR -

SEE SCHEDULE

1' - 0"

/2

5/8" GYPSUM BOARD

ON METAL STUD

FRAMING

ROLL-UP DOOR - SEE

SCHEDULE

5/8" GYPSUM BOARD ON

METAL STUD FRAMING

1/2" SOLID SURFACE SILL ON

2 LAYERS OF 1/2" PLYWOOD

SUBSTRATE

1/4" EASED PENCIL EDGE

(BOTH SIDES)

1/

2"

EQ.

8"

EQ.

LT. GA. METAL BOX HEADER

METAL STUD AND GYP. BD. PARTITION -

SEE PARTITION TYPES

ALUMINUM FRAME, TYP.

SEALANT ENTIRE

PERIMETER, TYP.

SHIM

DOOR (AS SCHEDULED)

2"

ALUMINUM FRAME

DOOR SEE DOOR SCHEDULE

GLAZING, TYP.

2"

4 1/2"

LT. GA. METAL BOX HEADER

METAL STUD AND GYP. BD. PARTITION -

SEE PARTITION TYPES

ALUMINUM FRAME, TYP.

SEALANT ENTIRE

PERIMETER, TYP.

SHIM

GLAZING, TYP.

2"

4 1/2"

ALUMINUM FRAME

SEALANT & BACKER ROD

CONT'S @ PERIM. (BOTH SIDES)

DOUBLE METAL STUD @ EA. JAMB

METAL STUD AND GYP. BD. PARTITION -

SEE PARTITION TYPES

SHIM

GLAZING, TYP.

2"

4 1/2"

ALUMINUM FRAME, TYP.

SEALANT ENTIRE

PERIMETER, TYP.

SHIM

GLAZING, TYP.

4"

4 1/2"

EXISTING CMU WALL

CONSTRUCTION TO REMAIN.

MODIFY AS REQURED FOR NEW

DOOR OPENING. CONTRACTOR

TO VERIFY IN FIELD ACTUAL WALL

CONDITION AND REPORT BACK

TO ARCHITECT OF ANY

DISCREPANCIES.

(2) 4"X6"X5/16" STEEL ANGLE LINTELS

EXISTING PLASTER

PLASTER TO MATCH EXISTING

4" METAL STUD

LT. GA. METAL BOX

HEADER

SECURITY ANCHOR AT

HEAD FOR FRAMES

WIDER THAN 3'-0"

SEALANT & BACKER ROD

CONT'S @ PERIM. (BOTH

SIDES)

1/4"

HOLLOW METAL FRAME

DOOR (AS SCHEDULED)

GYP. BD. TO MATCH

EXISTING OVER 4"

METAL STUD INFILL

MODIFY EXISTING

FURRING AS REQ'D

FOR NEW WORK

EXISTING CMU WALL

CONSTRUCTION TO REMAIN.

MODIFY AS REQURED FOR NEW

DOOR OPENING. CONTRACTOR

TO VERIFY IN FIELD ACTUAL WALL

CONDITION AND REPORT BACK

TO ARCHITECT OF ANY

DISCREPANCIES.

EXISTING PLASTER

WOOD BLOCKING

PLASTER TO MATCH EXISTING

SECURITY ANCHOR AT

JAMBS FOR FRAMES

WIDER THAN 3'-0"

HOLLOW METAL FRAME

DOOR (AS SCHEDULED)

GYP. BD. TO MATCH

EXISTING OVER

METAL FURRING,

MODIFY AS REQ'D

FOR NEW WORK

EXISTING GYP. BD. OVER

METAL FURRING

SEALANT & BACKER ROD

CONT'S @ PERIM. (BOTH

SIDES)

1/4" architecture · engineering

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERS · SURVEYORS · CONSULTANTS ·

LANDSCAPE ARCHITECTS · LAND PLANNERS

298 VETERANS DRIVE

FOWLERVILLE,

MICHIGAN 48836

(OFFICE) 517-223-3512

(FAX) 517-223-9987

211 E. Water Street, Suite 213L

Kalamazoo, MI 49007 269.216.0222

VA STATION

Battle Creek VA Medical Center

5500 Armstrong Road

Battle Creek, MI 49037

Defining

EXCELLENCE

in the 21st Century

HEALTH

CARE

C :\R ev it\

\1

4_

A _m ic he lle .b ur ri.

rv t

5/

/2

:2 6:

A

M

39-A503

DETAILS RENOVATE B39-2 WEST

FOR PATIENT PRIVACY

BATTLE CREEK, MI

515-20-102

05/20/2021 KJH MRB/MMN

100% BID DOCUMENTS190134

1/2" = 1'-0"

1 245 DAY ROOM - EXISTING TV & FIREPLACE

3/4" = 1'-0"39-A503

2 208 & 245 DAY ROOM - TV CABINET & FIREPLACE DETAIL

3/4" = 1'-0"39-A503

3 TV CABINET FIREPLACE DETAIL SECTION

1 1/2" = 1'-0"39-A503

4 FIREPLACE PLAN DETAIL

1 1/2" = 1'-0"39-A503

5 TV CABINET FIREPLACE PLAN DETAIL

1 1/2" = 1'-0"J6

OVERHEAD DOOR JAMB

1 1/2" = 1'-0"H5

OVERHEAD DOOR HEAD

1 1/2" = 1'-0"S1

OVERHEAD DOOR SILL

Revisions: Date:

RESUBMIT WITH OWNER CHANGES 10/02/2020

95% CONSTRUCTION DOCUMENTS 04/12/2021

100% BID DOCUMENTS 05/20/2021

1 1/2" = 1'-0"H6

ALUMINUM DOOR HEAD DETAIL

1 1/2" = 1'-0"J7

ALUMINUM DOOR JAMB DETAIL

1 1/2" = 1'-0"H7

ALUMINUM DOOR HEAD DETAIL

1 1/2" = 1'-0"J8

ALUMINUM DOOR JAMB DETAIL

1 1/2" = 1'-0"S2

ALUMINUM SILL DETAIL

1 1/2" = 1'-0"H8

HM DOOR HEAD AT EXISTING WALL

1 1/2" = 1'-0"J9

HM DOOR JAMB AT EXISTING WALL

(GLAZING AS

SCHEDULED)

NL

NARROW LITE

F

FLUSH

6" M

A X

. P E

R A

D A

4'

0"

HALF LITE

3'

6" 3'

2"

6"

7"7"

SCHEDULE

SEE

HL

SCHEDULE

SEE

S E

E S

C H

E D

U

LE

S E

E S

C H

E D

U

LE

S E

E S

C H

E D

U

LE

SCHEDULE

SEE

CCDD

4'

0"

3 1/2" +/-

1/

2"

(GLAZING AS

SCHEDULED)

MS

SCHEDULE

SEE

S E

E S

C H

E D

U

LE

MEDIUM STILE DUTCH DOOR COILING COUNTER DOOR

SCHEDULE

SEE

S E

E S

C H

E D

U

LE

SCHEDULE

SEE

S E

E S

C H

E D

U

LE

S E

E S

C H

E D

U

LE

SCHEDULE

SEE

DD2

3'

6"

4" 4"

4" 4"

DUTCH DOOR 2

NL2

NARROW LITE

6" M

A X

. P E

R A

D A

4'

0"

S E

E S

C H

E D

U

LE

SCHEDULE

SEE

6" 7"

(GLAZING AS

SCHEDULED)

12" 7"

(GLAZING AS

SCHEDULED)

(GLAZING AS

SCHEDULED)

1. ALL DOOR AND WINDOW FRAMES SHALL HAVE SEALANT & BACKER

ROD AT ENTIRE PERIMETER (BOTH SIDES,) UNO

2. REFER TO SPECIFICATIONS FOR HARDWARE SETS

3. ALL OUTSIDE DIMENSIONS OF FRAME TYPES ARE ROUGH OPENING

SIZES

4. MAINTAIN 4" MIN BETWEEN EDGE OF DOOR JAMB (HINGE SIDE) AND

NEAREST PERPENDICULAR SURFACE

5. ALL HOLLOW METAL FRAMES TO BE 2" PROFILE, UNO

6. STYLES & DIMENSIONS FOR DOOR TYPES & LITES ARE

REFLECTING DESIGN INTENT, DOOR MANUFACTURER TO SUBMIT

THEIR STANDARD TYPES, UNO

7. HM = HOLLOW METAL

8. WD = WOOD

9. AL = ALUMINUM

10. REFER TO SPECIFICATION FOR GLASS SCHEDULES AND

DESIGNATIONS

DOOR & FRAME GENERAL NOTES

IBG: INTEGRAL BLIND GLAZING

FR20: FIRE-RATED GLAZING - 20 MIN

FR90: FIRE-RATED GLAZING - 90 MIN

TG: TEMPERED GLAZING

LG: TEMPERED LAMINATED GLAZING

OWV: ONE-WAY-VISION LAMINATED GLAZING

ACR: ACRYLIC PANELS

RSN-1: LAMINATED RESIN PANELS

GLAZING NOTES

DOUBLE EGRESS

2" S

E E

D O

O R

S C

H E

D U

LE

2"

SCHEDULE

SEE DOOR 2"

S E

E D

O O

R S

C H

E D

U

LE

2"

2"

SCHEDULE

SEE DOOR 2"

01 03

2" S

E E

D O

O R

S C

H E

D U

LE

2"

SCHEDULE

SEE DOOR 2"

NO DOOR

STOP

SECURITY ANCHOR AT HEAD FOR

FRAMES WIDER THAN 3'-0"

SEALANT & BACKER ROD

CONT'S @ PERIM. (BOTH SIDES)

LT. GA. METAL BOX HEADER

METAL STUD AND GYP. BD. PARTITION -

SEE PARTITION TYPES

PARTITION THICKNESS + 1/8"

FRAME THROAT OPENING =

DOOR (AS SCHEDULED)

PAINTED WRAP-AROUND HOLLOW

METAL DRYWALL FRAME

DOOR (AS SCHEDULED)

LT. GA. METAL BOX HEADER

PAINTED WRAP-AROUND HOLLOW

METAL DRYWALL FRAME

SEALANT & BACKER ROD CONT'S

@ PERIM. (BOTH SIDES)

SECURITY ANCHOR AT HEAD

FOR FRAMES WIDER THAN 3'-0"

PARTITION THICKNESS + 1/8"

FRAME THROAT OPENING =

METAL STUD AND GYP. BD. PARTITION -

SEE PARTITION TYPES

PARTITION THICKNESS + 1/8"

FRAME THROAT OPENING =

LT. GA. METAL BOX HEADER

SEALANT & BACKER ROD

CONT'S @ PERIMETER

(BOTH SIDES)

PAINTED WRAP-AROUND

HOLLOW METAL DOUBLE

EGRESS DRYWALL FRAME

DOOR STOP (BEYOND)

DOOR (AS SCHEDULED)

A B

C

NOTE: SHOWING SWING

OF DOUBLE EGRESS

PLAN

NOTE: SHOWING

THE SWING OF

DOUBLE EGRESS

DOORS

C

DOUBLE EGRESS DOOR FRAME

A B

METAL STUD AND GYP. BD. PARTITION -

SEE PARTITION TYPES

DOOR SEE DOOR SCHEDULE

WRAP-AROUND HOLLOW METAL FRAME,

PAINT - SEE DOOR SCHEDULE

JAMB ANCHORS (2 PER JAMB &

ADJ. BASE ANCHORS - TYP.)

SEALANT & BACKER ROD

CONT'S @ PERIM. (BOTH SIDES)

DOUBLE METAL STUD @ EA. JAMB

METAL STUD AND GYP. BD. PARTITION -

SEE PARTITION TYPES

PARTITION THICKNESS + 1/8"

FRAME THROAT OPENING =

DOOR (AS SCHEDULED)

DOUBLE METAL STUD @ EA.

JAMB

JAMB ANCHORS (2 PER JAMB-

& ADJ. BASE ANCHORS - TYP.)

PAINTED WRAP-AROUND

HOLLOW METAL DRYWALL

FRAME

SEALANT & BACKER ROD

CONT'S @ PERIM. (BOTH

SIDES)

PARTITION THICKNESS + 1/8"

FRAME THROAT OPENING =

A

B

PLAN

NOTE: SHOWING

THE SWING OF

DOUBLE EGRESS

DOORS

3/

8" S

E E

D O

O R

S

C H

E D

U

LE

DETAIL 'A'

DETAIL 'B'

DOOR (AS SCHEDULED)

DOUBLE METAL STUD @ EA.

JAMB

JAMB ANCHORS (2 PER JAMB-

& ADJ. BASE ANCHORS - TYP.)

PAINTED WRAP-AROUND

HOLLOW METAL DRYWALL

FRAME

SEALANT & BACKER ROD

CONT'S @ PERIM. (BOTH SIDES)

DOOR SEE DOOR SCHEDULE

WRAP-AROUND HOLLOW METAL FRAME,

PAINT - SEE DOOR SCHEDULE

JAMB ANCHORS (2 PER JAMB &

ADJ. BASE ANCHORS - TYP.)

SEALANT & BACKER ROD

CONT'S @ PERIM. (BOTH SIDES)

DOUBLE METAL STUD @ EA. JAMB

METAL STUD AND GYP. BD. PARTITION -

SEE PARTITION TYPES

PARTITION THICKNESS + 1/8"

FRAME THROAT OPENING =

DOOR SEE DOOR SCHEDULE

WRAP-AROUND HOLLOW METAL FRAME,

PAINT-SEE DOOR SCHEDULE

SECURITY ANCHOR AT HEAD FOR

FRAMES WIDER THAN 3'-0"

SEALANT & BACKER ROD

CONT'S @ PERIM. (BOTH SIDES)

LT. GA. METAL BOX HEADER

METAL STUD AND GYP. BD. PARTITION -

SEE PARTITION TYPES

PARTITION THICKNESS + 1/8"

FRAME THROAT OPENING =

W1

RSN-1

LG

RSN-1

LG

RSN-1

LG

RSN-1

LG

RSN-1

LG

RSN-1

LG

RSN-1

LG

RSN-1

LG

RSN-1

LG

RSN-1

LG

RSN-1

LG

RSN-1

LG

RSN-1

LG

RSN-1

LG

RSN-1

LG

RSN-1

LG

RSN-1

OPEN

EQ.EQ.EQ.EQ.7' - 1 1/2"EQ.EQ.EQ.EQ.

CURVED

35' 0 1/2" N.T.S.

E Q

E Q

E Q

1'

8"

8'

8"

W2

RSN-1

LG

RSN-1

LG

8'

8"

EQ. EQ.

RSN-1

LG

RSN-1

LG

E Q

E Q

E Q

1'

8"

FLOOR LINE

W3

3'

6" 3'

8"

7'

2"

6' - 0"

ALUMINUM STOREFRONTALUMINUM STOREFRONTALUMINUM STOREFRONT

LG

EQ.

SCHEDULE

SEE DOOR EQ.

LG LG

W4

ALUMINUM STOREFRONT

S E

E D

O O

R S

C H

E D

U

LE

4"

EXISTING TO REMAIN

DOOR FRAME - SEE

FRAME TYPES, TYP.

BACKER ROD &

SEALANT, TYP.

SEALANT

GYP. BD. OVER

EXISTING

CONSTRUCTION

SEE REFLECTED

CEILING PLAN

SEE REFLECTED

CEILING PLAN

SEE REFLECTED

CEILING PLAN

EXISTING TO REMAIN, TYP.

EXISTING LINTEL TO

REMAIN, PAINT

GYP. BD. OVER EXISTING

CONSTRUCTION

BACKER ROD &

SEALANT, TYP.

HOLLOW METAL FRAME -

SEE FRAME TYPES

SEALANT, TYP.

SEALANT CONT'S @ PERIM.

(BOTH SIDES)

DOUBLE METAL STUD @ EA. JAMB

METAL STUD AND GYP. BD. PARTITION -

SEE PARTITION TYPES

DOOR SEE DOOR SCHEDULE

DOOR STOP LEAF

STRIKE

architecture · engineering

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERS · SURVEYORS · CONSULTANTS ·

LANDSCAPE ARCHITECTS · LAND PLANNERS

298 VETERANS DRIVE

FOWLERVILLE,

MICHIGAN 48836

(OFFICE) 517-223-3512

(FAX) 517-223-9987

211 E. Water Street, Suite 213L

Kalamazoo, MI 49007 269.216.0222

VA STATION

Battle Creek VA Medical Center

5500 Armstrong Road

Battle Creek, MI 49037

Defining

EXCELLENCE

in the 21st Century

HEALTH

CARE

C :\R ev it\

\1

4_

A _m ic he lle .b ur ri.

rv t

5/

/2

:2 6:

A

M

39-A601

SCHEDULES & DIAGRAMS RENOVATE B39-2 WEST

FOR PATIENT PRIVACY

BATTLE CREEK, MI

515-20-102

05/20/2021 KJH MRB/MMN

100% BID DOCUMENTS190134

DOOR AND FRAME SCHEDULE

DOOR

NO.

ROOM

NO. ROOM NAME

DOOR FRAME

FIRE

RATING

HARDWARE

SET NO. NOTES

SIZE

MATL TYPE GLAZING MATL TYPE

DETAIL

WD. HGT HEAD JAMB SILL

01.0

B113.A B113 NURSE STATION 3' - 0" 7' - 0" WD DD2 LG - - 11 / 39-A502 9 &15 / 39-A502 - - 19 REFER TO NURSE STATION DETAILS FOR HEAD AND JAMB FRAME DETAILS

B113.B B113 NURSE STATION 3' - 0" 7' - 0" WD DD2 LG - - 11 / 39-A502 9 &15 / 39-A502 - - 19 REFER TO NURSE STATION DETAILS FOR HEAD AND JAMB FRAME DETAILS

BC-13.A BC-13 CORRIDOR 7' - 0" 7' - 0" WD NL LG HM 03 J3 / 39-A601 H3 / 39-A601 - - 28 PAIR OF DOORS

C14A.A C14A NURSE STATION 3' - 0" 6' - 8" WD HL LG - - 13 / 39-A502 9 &14 / 39-A502 - - 24 REFER TO NURSE STATION DETAILS FOR HEAD AND JAMB FRAME DETAILS

C14A.B C14A NURSE STATION 3' - 0" 6' - 8" WD DD2 LG - - 11 / 39-A502 9,10,&12 / 39-A502 - - 19 REFER TO NURSE STATION DETAILS FOR HEAD AND JAMB FRAME DETAILS

C18A.A C18A NURSE STATION 3' - 0" 6' - 8" WD HL LG - - 13 / 39-A502 9 &14 / 39-A502 - - 24 REFER TO NURSE STATION DETAILS FOR HEAD AND JAMB FRAME DETAILS

C18A.B C18A NURSE STATION 3' - 0" 6' - 8" WD DD2 LG - - 11 / 39-A502 9,10,&12 / 39-A502 - - 19 REFER TO NURSE STATION DETAILS FOR HEAD AND JAMB FRAME DETAILS

02.0 ORIGINAL

208A.A 208A GROUP ROOM 4' - 0" 7' - 0" WD NL - HM 01 H1 / 39-A601 J1 / 39-A601 - - 04

245A.A 245A GROUP ROOM 4' - 0" 7' - 0" WD NL - HM 01 H1 / 39-A601 J1 / 39-A601 - - 04

C23A.B C23A NURSE STATION 3' - 0" 6' - 8" WD DD2 LG - - 11 / 39-A502 9,10,&12 / 39-A502 - - 19 REFER TO NURSE STATION DETAILS FOR HEAD AND JAMB FRAME DETAILS

C23A.A C23A NURSE STATION 3' - 0" 6' - 8" WD HL LG - - 13 / 39-A502 9 &14 / 39-A502 - - 24 REFER TO NURSE STATION DETAILS FOR HEAD AND JAMB FRAME DETAILS

C28A.B C28A NURSE STATION 3' - 0" 6' - 8" WD DD2 LG - - 11 / 39-A502 9,10,&12 / 39-A502 - - 19 REFER TO NURSE STATION DETAILS FOR HEAD AND JAMB FRAME DETAILS

C28A.A C28A NURSE STATION 3' - 0" 6' - 8" WD HL LG - - 13 / 39-A502 9 &14 / 39-A502 - - 24 REFER TO NURSE STATION DETAILS FOR HEAD AND JAMB FRAME DETAILS

C-24.A C-24 CORRIDOR 4' - 0" 7' - 0" WD NL - HM 01 H8 / 39-A503 J9 / 39-A503 - - 17

C-30.A C-30 CORRIDOR 4' - 0" 7' - 0" WD NL - HM 01 H8 / 39-A503 J9 / 39-A503 - - 17

02.0 ADDITION

B201.A B201 STAFF LOCKER RM / LOUNGE 3' - 4" 7' - 0" WD F - HM 01 H1 / 39-A601 J1 / 39-A601 - - 20

B202.A B202 SOILED LINEN 3' - 4" 7' - 0" WD F - HM 01 H1 / 39-A601 J1 / 39-A601 - 45 MIN 10 1 HR FIRE RESISTANCE RATED FIRE BARRIER

B204.A B204 HSK EQUIP. 3' - 4" 7' - 0" WD F - HM 01 H1 / 39-A601 J1 / 39-A601 - 45 MIN 10 1 HR FIRE RESISTANCE RATED FIRE BARRIER

B205.A B205 CLEAN LINEN 3' - 4" 7' - 0" WD F - HM 01 H1 / 39-A601 J1 / 39-A601 - 45 MIN 10 1 HR FIRE RESISTANCE RATED FIRE BARRIER

B206.A B206 TREATMENT 3' - 6" 7' - 0" WD NL LG HM 01 H1 / 39-A601 J1 / 39-A601 - - 14

B207.A B207 OFFICE 3' - 0" 7' - 0" WD NL LG HM 01 H1 / 39-A601 J1 / 39-A601 - - 13

B208.A B208 OFFICE 3' - 0" 7' - 0" WD NL LG HM 01 H1 / 39-A601 J1 / 39-A601 - - 13

B209.A B209 OFFICE 3' - 0" 7' - 0" WD NL LG HM 01 H1 / 39-A601 J1 / 39-A601 - - 13

B210.A B210 OFFICE 3' - 0" 7' - 0" WD NL LG HM 01 H1 / 39-A601 J1 / 39-A601 - - 13

B211.B B211 NURSE OFFICE 3' - 0" 7' - 0" WD HL IBG HM 01 H1 / 39-A601 J1 / 39-A601 - - 16

B211.A B211 NURSE OFFICE 3' - 0" 7' - 0" WD HL IBG HM 01 H1 / 39-A601 J1 / 39-A601 - - 13

B212.A B212 OFFICE 3' - 0" 7' - 0" WD NL LG HM 01 H1 / 39-A601 J1 / 39-A601 - - 13

B213.A B213 NURSE STATION 3' - 3" 7' - 0" WD DD2 LG HM 01 H1 / 39-A601 J1 / 39-A601 - - 19

B213A.A B213A STORAGE 3' - 0" 7' - 0" WD F - HM 01 H1 / 39-A601 J1 / 39-A601 - - 07

B218A.A B218 DAY ROOM 3' - 0" 7' - 0" WD F - HM 01 H1 / 39-A601 J1 / 39-A601 - - 08

B220.A B220 NOURISH 3' - 4" 7' - 0" WD NL LG HM 01 H1 / 39-A601 J1 / 39-A601 - - 21

B220.B B220 NOURISH 3' - 0" 7' - 0" WD NL LG HM 01 H1 / 39-A601 J1 / 39-A601 - - 22

B220.C B220 NOURISH 4' - 0" 4' - 2" STL CC - STL - H5 / 39-A503 J6 / 39-A503 S1 / 39-A503 - 29 OVERHEAD DOOR

B221.A B221 S. TOILET 3' - 6" 7' - 0" WD F - HM 01 H1 / 39-A601 J1/39-A601 - - 03

B222.A B222 QUIET 3' - 10" 7' - 0" WD F - HM 01 H1 / 39-A601 J1/39-A601 - - 26

B222.B B222 QUIET 3' - 6" 7' - 0" WD HL OWV HM 01 H1 / 39-A601 J1/39-A601 - - 26

B223.A B223 SEMI 3' - 10" 7' - 0" WD HL IBG HM 02 H2 / 39-A601 J5 / 39-A601 - - 15

B223A.A B223A BATHROOM 3' - 6" 7' - 0" - - - HM 02 H2 / 39-A601 J2 / 39-A601 - - 30 FRAME ONLY

B224.A B224 ANTE ROOM 3' - 6" 7' - 0" WD F IBG HM 01 H1 / 39-A601 J1 / 39-A601 - - 05

B224A.A B224A BATHROOM 3' - 6" 7' - 0" WD F - HM 01 H1 / 39-A601 J1 / 39-A601 - - 01

B225.A B225 SEMI 3' - 10" 7' - 0" WD HL IBG HM 02 H2 / 39-A601 J5 / 39-A601 - - 15

B225A.A B225A BATHROOM 3' - 6" 7' - 0" - - - HM 02 H2 / 39-A601 J2 / 39-A601 - - 30 FRAME ONLY

B226.A B226 MEDICAL BEDROOM 3' - 10" 7' - 0" WD F - HM 01 H1 / 39-A601 J1 / 39-A601 - - 26

B226.B B226 MEDICAL BEDROOM 3' - 6" 7' - 0" WD HL OWV HM 01 H1 / 39-A601 J1 / 39-A601 - - 26

B227.A B227 SEMI 3' - 10" 7' - 0" WD HL IBG HM 02 H2 / 39-A601 J5 / 39-A601 - - 15

B227A.A B227A BATHROOM 3' - 6" 7' - 0" - - - HM 02 H2 / 39-A601 J2 / 39-A601 - - 30 FRAME ONLY

B228.A B228 PRIVATE 3' - 10" 7' - 0" WD HL IBG HM 02 H2 / 39-A601 J5 / 39-A601 - - 15

B228A.A B228A BATHROOM 3' - 6" 7' - 0" - - - HM 02 H2 / 39-A601 J2 / 39-A601 - - 30 FRAME ONLY

B230.A B230 PRIVATE 3' - 10" 7' - 0" WD HL IBG HM 02 H2 / 39-A601 J5 / 39-A601 - - 15

B230A.A B230A BATHROOM 3' - 6" 7' - 0" - - - HM 02 H2 / 39-A601 J2 / 39-A601 - - 30 FRAME ONLY

B232.A B232 LAUNDRY 3' - 0" 7' - 0" WD F - HM 01 H1 / 39-A601 J1 / 39-A601 - - 06

B234.A B234 STORAGE 3' - 0" 7' - 0" WD F - HM 01 H1 / 39-A601 J1 / 39-A601 - - 11

B240.A B240 HSK 3' - 6" 7' - 0" WD F - HM 01 H1 / 39-A601 J1 / 39-A601 - 20 MIN 12 1/2 HR FIRE RESISTANCE RATED SMOKE PARTITION

B241.A B241 MEDS 3' - 4" 7' - 0" WD DD - HM 01 H1 / 39-A601 J1 / 39-A601 - - 18

B242.A B242 SEMI 3' - 10" 7' - 0" WD HL IBG HM 02 H2 / 39-A601 J5 / 39-A601 - - 15

B242A.A B242A BATHROOM 3' - 6" 7' - 0" - - - HM 02 H2 / 39-A601 J2 / 39-A601 - - 30 FRAME ONLY

B243.A B243 PRIVATE 3' - 10" 7' - 0" WD HL IBG HM 02 H2 / 39-A601 J5 / 39-A601 - - 15

B243A.A B243A BATHROOM 3' - 6" 7' - 0" - - - HM 02 H2 / 39-A601 J2 / 39-A601 - - 30 FRAME ONLY

B244.A B244 SEMI 3' - 10" 7' - 0" WD HL IBG HM 02 H2 / 39-A601 J5 / 39-A601 - - 15

B244A.A B244A BATHROOM 3' - 6" 7' - 0" - - - HM 02 H2 / 39-A601 J2 / 39-A601 - - 30 FRAME ONLY

B245.A B245 PRIVATE 3' - 10" 7' - 0" WD HL IBG HM 02 H2 / 39-A601 J5 / 39-A601 - - 15

B245A.A B245A BATHROOM 3' - 6" 7' - 0" - - - HM 02 H2 / 39-A601 J2 / 39-A601 - - 30 FRAME ONLY

B246.A B246 SEMI 3' - 10" 7' - 0" WD HL IBG HM 02 H2 / 39-A601 J5 / 39-A601 - - 15

B246A.A B246A BATHROOM 3' - 6" 7' - 0" - - - HM 02 H2 / 39-A601 J2 / 39-A601 - - 30 FRAME ONLY

B247.A B247 PRIVATE 3' - 10" 7' - 0" WD HL IBG HM 02 H2 / 39-A601 J5 / 39-A601 - - 15

B247A.A B247A BATHROOM 3' - 6" 7' - 0" - - - HM 02 H2 / 39-A601 J2 / 39-A601 - - 30 FRAME ONLY

B249.A B249 PRIVATE 3' - 10" 7' - 0" WD HL IBG HM 02 H2 / 39-A601 J5 / 39-A601 - - 15

B249A.A B249A BATHROOM 3' - 6" 7' - 0" - - - HM 02 H2 / 39-A601 J2 / 39-A601 - - 30 FRAME ONLY

B251.A B251 STORAGE 3' - 0" 7' - 0" WD F - HM 01 H1 / 39-A601 J1 / 39-A601 - 20 MIN 11 1/2 HR FIRE RESISTANCE RATED SMOKE PARTITION

B253.A B253 SOILED UTILITY 3' - 0" 7' - 0" WD F LG HM 01 H1 / 39-A601 J1 / 39-A601 - - 09

BC-22.A BC-22 CORRIDOR 7' - 0" 7' - 0" WD NL LG HM 03 H3 / 39-A601 J3 / 39-A601 - - 27

BC-23.A BC-23 CORRIDOR 7' - 0" 7' - 0" WD NL LG HM 03 H3 / 39-A601 J3 / 39-A601 - - 27

BC-25.2.A BC-24 CORRIDOR 3' - 6" 7' - 0" AL MS LG AL W4 H6 & H7 /

39-A503

J7 & J8 / 39-A503 S2 / 39-A503 - 23

BC-25.1.B BC-25.1 CORRIDOR 3' - 4" 7' - 0" WD NL FR-90 HM 01 H4 / 39-A601 J4 / 39-A601 - 90 MIN 25 2 HR FIRE RESISTANCE RATED FIRE BARIER

BC-25.2.1 BC-25.2 CORRIDOR 7' - 2" 7' - 0" - - - HM 02 2 / 39-A601 1 / 39-A601 - - 30 FRAME ONLY

BC-27.2.A BC-26 CORRIDOR 3' - 6" 7' - 0" AL MS LG AL W4 H6 & H7 /

39-A503

J7 & J8 / 39-A503 S2 / 39-A503 - 23

BC-26.A BC-26 CORRIDOR 7' - 0" 7' - 0" WD NL FR-20 HM 03 H3 / 39-A601 J3 / 39-A601 - 20 MIN 02 1 HR FIRE RESISTANCE RATED SMOKE BARRIER

BC-27.1.B BC-27.1 CORRIDOR 3' - 4" 7' - 0" WD NL FR-90 HM 01 H4 / 39-A601 J4 / 39-A601 - 90 MIN 25 2 HR FIRE RESISTANCE RATED FIRE BARRIER

BC-27.2.1 BC-27.2 CORRIDOR 7' - 2" 7' - 0" - - - HM 02 2 / 39-A601 1 / 39-A601 - - 30 FRAME ONLY

1/4" = 1'-0"

DOOR TYPES

1/4" = 1'-0"

DOOR FRAME TYPES

1 1/2" = 1'-0"

H1 DOOR HEAD DETAIL

1 1/2" = 1'-0"

H2 DOOR HEAD DETAIL @ NO DOOR STOP

1 1/2" = 1'-0"

H3 DOOR HEAD DETAIL @ DOUBLE EGRESS

1 1/2" = 1'-0"

J1 DOOR JAMB DETAIL

1 1/2" = 1'-0"

J2 DOOR JAMB DETAIL @ NO DOOR STOP

1 1/2" = 1'-0"

J3 DOOR JAMB DETAIL @ DOUBLE EGRESS

1 1/2" = 1'-0"

J4 DOOR JAMB DETAIL @ 2-HR WALL

1 1/2" = 1'-0"

H4 DOOR HEAD DETAIL @ 2-HR WALL

1/4" = 1'-0"

STOREFRONT TYPES

1 1/2" = 1'-0"39-A133

1 WALL OPENING JAMB DETAIL

1 1/2" = 1'-0"39-A112

2 WALL OPENING DETAIL

1 1/2" = 1'-0"

J5 DUAL EGRESS JAMB DETAIL

Revisions: Date:

65% DESIGN DEVELOPMENT 03/06/2020

RESUBMIT WITH OWNER CHANGES 10/02/2020

DN DN

DAY ROOM

B218

MEDS

B241

ELEVATOR

TREATMENT

B206

OFFICE

B208

OFFICE

B212

GROUP ROOM

B214

OFFICE

B207

OFFICE

B209

CORRIDOR

BC-22.2

PRIVATE

B230

PRIVATE

B228

SEMI

B223

SEMI

B225

SEMI

B227

S. TOILET

B221

QUIET

B222

MEDICAL

BEDROOM

B226

ANTE ROOM

B224

NOURISH

B220

PRIVATE

B243PRIVATE

B245

PRIVATE

B249

PRIVATE

B247

SEMI

B242SEMI

B244

SEMI

B246

HSK

B240

STORAGE

B251

STAIR

STAIR

SOILED UTILITY

B253

SOILED LINEN

B202

STAFF LOCKER

RM / LOUNGE

B201

CLEAN LINEN

B205

HSK EQUIP.

B204

BATHROOM

B246A

BATHROOM

B244A

BATHROOM

B242A

BATHROOM

B247A

BATHROOM

B243A

BATHROOM

B245A

BATHROOM

B223A

BATHROOM

B224A

BATHROOM

B225A

BATHROOM

B227A

BATHROOM

B230A

CORRIDOR

BC-22

ELECTRICAL

B255

ELECTRICAL

B236

CORRIDOR

BC-23

CORRIDOR

C-24 CORRIDOR

C-30

CORRIDOR

BC-21

STORAGE

B213A

STORAGE

B218A

CORRIDOR

BC-27.2

CORRIDOR

BC-24

CORRIDOR

BC-25.2

DAY ROOM

NOURISHMENT

232E

MED ROOM

207A

STAFF ROOM

CLEAN UTILITY

206B

LAUNDRY

206A

SOILED UTILITY

PHYSICIAN

PHYSICIAN

ASST.

OFFICE

NURSING 2

BED

NURSING 2

BED

NURSING 2

BED

PHYSICIAN

ASSISTANT

NURSING 1

BED

NURSING 1

BED

NURSING 1

BED

NURSING 1

BED

LAUNDRY

SOILED UTILITY

247A

STAFF ROOM

MED ROOM

243A

NOURISHMENT

245E

DAY ROOM

CORRIDOR

BC-27.1

CORRIDOR

BC-25.1

STAFF TOILET

208D

SECLUSION

CORRIDOR

C22 STAFF TOILET

245D

SECLUSION

CORRIDOR

C21

39-I102

39-I102

EXISTING FLOORING

TO REMAIN

EXISTING MATERIALS

TO REMAIN

NURSE

STATION

C23A

NURSE

STATION

C28A

CORRIDOR

C28

MB-2MB-2

WP-1WP-1

CORRIDOR

BC-22.2

P-3P-3 P-3P-3

P-2P-2

P-3P-3

NURSE OFFICE

B211

NURSE

STATION

B213

3' - 0"

2' - 0" 2' - 0"

2'

0"

2'

0"

STORAGE

B234

LAUNDRY

B232

OFFICE

B210

P-2P-2

3'

0"

39-I601

39-I601

39-I601

39-I601

39-I601

39-I601

P-3P-3

BATHROOM

B228A

BATHROOM

B249A

39-I102

SIM.

39-I102

SIM.

39-I102

SIM.

39-I102

SIM.

39-I102

SIM.

39-I102

SIM.

39-I102

SIM.

39-I102

SIM.

39-I102

SIM.

39-I102

SIM.

P-2P-2

P-2P-2

CORRIDOR

BC-26

P-3P-3

P-2P-2

P-2P-2

P-3P-3

2 NORTH

2 SOUTH

INFILL

FLOORING

TO MATCH

EXISTING

P-2P-2

P-2P-2

2' - 0" 2' - 0"

2'

0"

2' - 0"

P-1P-1

PATCH USING

ATTIC STOCK

2' - 0" 2' - 0"

2' - 0"

9'

4"

9'

4"

5'

4"

MATERIALS LEGEND

RF-2

RF-5

RF-3 (DIRECTION OF PATTERN

NOTES DIRECTION OF FLOORING)

RF-4

RF-6

RF-1

CPT-1

RF-7

ROOM FINISH GENERAL NOTES

1. DOOR FRAME COLOR CHANGES SHALL OCCUR ON STOP AS IF DOOR IS IN CLOSED POSITION WITH THE DOOR AND FRAME SHOWING

AS ONE COLOR.

2. FLOORING TRANSITIONS SHALL BE CENTERED UNDER DOOR WHILE IN CLOSED POSITION. PROVIDE TRANSITION STRIP BETWEEN ALL

FLOORING MATERIAL TRANSITIONS.

3. ALL EXPOSED STRUCTURAL, PLUMBING, MECHANICAL AND ELECTRICAL ELEMENTS ARE TO BE PAINTED TO MATCH ADJACENT WALL, U.N.O.

4. ALL CEILING GRIDS ARE TO BE CENTERED IN THE SPACE IN BOTH DIRECTIONS (AS SHOWN) UNLESS NOTED OTHERWISE.

5. ELECTRICAL DEVICES SUCH AS PLUG MOLDS, CHASES, PANELS, ETC. SHALL BE PAINTED TO MATCH ADJACENT WALL COLOR.

ELECTRICAL RECEPTACLE COVER PLATES (EXCEPT IN WOOD), SWITCH PLATES & TOGGLES, TELEPHONE/DATA COVERPLATES (EXCEPT IN WOOD) SHALL BE NYLON, COLOR: WHITE. THERMOSTAT COVERS SHALL BE COLOR: WHITE. ANY ELECTRICAL DEVICES MOUNTED IN WOOD PANELING, WAINSCOT OR TRIM SHALL MATCH THE FINISH/COLOR OF THE ADJACENT WOOD.

6. FIRE EXTINGUISHER CABINETS SHALL BE PAINTED TO MATCH ADJACENT WALL SURFACE COLOR. FIRE ALARMS SHALL BE RED.

7. ANY EXPOSED MECHANICAL GRILLES, METAL PANELS, TRIM DEVICES SHALL BE PAINTED TO MATCH ADJACENT SURFACE COLOR.

8. WINDOW SILLS SHALL BE SOLID SURFACE, SEE MATERIALS SCHEDULE FINISH SSM-1.

9. INTERIOR HOLLOW METAL DOORS, DOOR FRAMES, AND WINDOW FRAMES SHALL BE PAINTED P-5, U.N.O.

10. WOOD DOORS, DOOR FRAMES AND WINDOW FRAMES SHALL BE STAINED.

11. TRANSITION STRIP BETWEEN CARPET AND RESILIENT FLOORING AND/OR CONCRETE SHALL BE JOHNSONITE TA7 RUSTY NAIL.

12. GYP. BD. CEILINGS AND BULKHEADS TO BE PAINTED, BOTTOM OF BULKHEADS TO BE PAINTED TO MATCH CEILING, SIDES TO MATCH

ADJACENT WALL U.N.O, SEE ROOM FINISH AND MATERIALS SCHEDULES, I-601.

13. CORNER GUARDS TO BE LOCATED AT ALL OUTSIDE CORNERS. SEE I-601 MATERIALS SCHEDULE CODE CG-1.

14. CONVECTOR, CABINET UNIT HEATERS AND FIN-TUBE UNITS SHALL BE PAINTED TO MATCH ADJACENT WALL COLOR, U.N.O.

15. SEE INTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION REGARDING INTERIOR FINISHES.

16. ALL EXPOSED WOOD TRIM AND VENEER SHALL BE HARDWOOD, STAINED, AND VARNISHED.

17. CHEMICAL WELD SEAM BETWEEN DISSIMILAR MATERIALS (IE: RESILIENT SHEET TO RESILIENT TILE) AND HEAT WELD SEAM BETWEEN

SIMILAR MATERIALS (IE: RESILIENT SHEET TO RESILIENT SHEET).

18. ALL MARKERBOARDS TO BE INSTALLED AT 7’-0” A.F.F TO TOP OF BOARD U.N.O.

19. ALL TV MONITORS TO BE INSTALLED AT 5’-0” A.F.F. TO CENTER OF MONITOR U.N.O.

E Q

6'

9" E

Q

8' - 6"

7' - 2"

0"

P-3P-3

CHEMICAL WELD SEAM BETWEEN

MATERIAL TRANSITION

EQ EQ

WP-2WP-2

E Q

6'

9" 3'

6'

9"

E Q

8' - 6"

CENTERED ON DOOR

7' - 2"

CHEMICAL WELD SEAM BETWEEN

MATERIAL TRANSITION

8' - 6"

P-3P-3

WP-2WP-2

NURSE

STATION

C14A

INFILL

FLOORING

TO MATCH

EXISTING

NURSE

STATION

C18A

CORRIDOR

C18

INFILL

FLOORING

TO MATCH

EXISTING

NURSE

STATION

B113

INFILL

FLOORING

TO MATCH

EXISTING

architecture · engineering

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERS · SURVEYORS · CONSULTANTS ·

LANDSCAPE ARCHITECTS · LAND PLANNERS

298 VETERANS DRIVE

FOWLERVILLE,

MICHIGAN 48836

(OFFICE) 517-223-3512

(FAX) 517-223-9987

211 E. Water Street, Suite 213L

Kalamazoo, MI 49007 269.216.0222

VA STATION

Battle Creek VA Medical Center

5500 Armstrong Road

Battle Creek, MI 49037

Defining

EXCELLENCE

in the 21st Century

HEALTH

CARE

C :\R ev it\

\1

4_

A _m ic he lle .b ur ri.

rv t

5/

/2

:2 6:

A

M

39-I102

PARTIAL FINISH PLAN - SECOND

LEVEL

RENOVATE B39-2 WEST

FOR PATIENT PRIVACY

BATTLE CREEK, MI

515-20-102

05/20/2021 AAP CJA

100% BID DOCUMENTS190134

1/8" = 1'-0"

PARTIAL SECOND FLOOR FINISH PLAN

1/4" = 1'-0"39-I102

5 ENLARGED PLAN PRIVATE PATIENT ROOMS, TYP FINISH PLAN

1/4" = 1'-0"39-I102

4 ENLARGED PLAN SEMI-PRIVATE PATIENT, TYP FINISH PLAN

NOT TO SCALE

KEY PLAN SECOND FLOOR1/8" = 1'-0"39-A101

3 NURSE STATION 1 NORTH - FINISH PLAN

1/8" = 1'-0"39-A101

1 NURSE STATION 1 SOUTH - FINISH PLAN

1/8" = 1'-0"39-A101

2 NURSE STATION 1 WEST - FINISH PLAN

Revisions: Date:

65% DESIGN DEVELOPMENT 03/06/2020

RESUBMIT WITH OWNER CHANGES 10/02/2020

0' - 9"

0'

3"

0' - 0 25/32"

GRADE 2 BRAILLE

ROOM NO. 1-1/4" HIGH

RAISED HELVETICA TEXT

TAMPER RESISTANT FASTENER TYP.

RADIUS CORNERS TYP.

XXXXXXX

XXXXXXX

0' - 9"

9"

ROOM NO. 11/4" HIGH

RAISED HELVETICA TEXT

ROOM NAME. 1"

HIGH RAISED

HELVETICA TEXT

GRADE 2 BRAILLE

GRADE 2 BRAILLE

TAMPER RESISTANT

FASTENER TYP

RADIUS CORNERS

TYP.

0' - 9"

0'

9"

ROOM NO. 11/4" HIGH

RAISED HELVETICA TEXT

GRADE 2 BRAILLE

TAMPER RESISTANT

FASTENER TYP.

RADIUS CORNERS TYP.

1/

2"

1/ 2"

MARKER BOARD

0' - 0 3/8"

0'

3/

8" 0'

3/

0'

3/ 8"

9" HIGH

HELVETICA

TEXT

1" HIGH HELVETICA

TEXT BOLD

20"

E Q

E Q

E Q

E Q

E Q

E Q

TEXT

TEXT

13/8" HIGH HELVETICA TEXT, TYP.

LEFT JUSTIFY

REMOVABLE INSERT

TYP.

TAMPER RESISTANT

FRAME

NO EXPOSED FASTENERS

TYP.

TEXT

TEXT

2 1/2" ARROW TYP.

20"

E Q

E Q

E Q

E Q

E Q

E Q

TEXT

TEXT

13/8" HIGH HELVETICA TEXT, TYP.

LEFT JUSTIFY

REMOVABLE INSERT

TYP.

TAMPER RESISTANT

FRAME

NO EXPOSED

FASTENERS TYP.

TEXT

TEXT

2 1/2" ARROW TYP.

0' - 9"

0'

9"

XXX TOILET

3/4" HIGH

HELVETICA TEXT

GRADE 2 BRAILLE

SYMBOL

TAMPER

RESISTANT

FASTENER TYP.

RADIUS

CORNERS TYP.

0' - 9"

0'

9"

0'

3/

STAIRS

0'

1/

3/4" HIGH

HELVETICA TEXT

GRADE 2 BRAILLE

SYMBOL

RADIUS

CORNERS TYP.

TAMPER

RESISTANT

FASTENER TYP.

0'

6"

40"

3" HIGH HELVETICA

TEXT. ARROW AND

TEXT BOTH SIDES

ELEVATOR

E Q

E Q

G.Y.P. CEILING

ELEV. = 9'-0" (TYP.) U.N.O.

BOTTOM OF SIGN

ELEV. = 7'-0" (MIN.)

ANGLE BRACKETS

BOTH SIDES

0' - 2"

5'

3"

SIGNAGE GENERAL NOTES

1. ALL COPY TO BE VERIFIED WITH CLIENT PRIOR TO FABRICATION

2. ANY SIGNAGE APPLIED TO GLASS NEEDS A BACKER PANEL

3. DETAIL VIEW TITLES INDICATES VA SIGN FAMILY AND NUMBER

96"

VA

U.S. Department of Veterans Affairs

Battle Creek

VA Medical Center

GENERAL CONTRACTOR

Construction Firm Name City State

ARCHITECT / ENGINEER

Architect/ Engineering Firm Name City State

VA Office of Construction & Facilities Management

FRAMED SIGN PANEL - ALUMINUM SKIN

LAMINATED TO A WOOD CORE WITH

PHYSICALLY SEALED EDGES

TY

P

6" M

IN

TYP

6" MIN

TYP

6" MIN

VA BLUE (PANTONE 541) BACKGROUND

DEPARTMENT OF VETERAN AFFAIRS

LOGO - SURFACE APPLIED VINYL OR

SCREENED GRAPHICS - COLOR WHITE

SURFACE APPLIED VINYL OR SCREENED

GRAPHICS - COLOR BLACK

WHITE BACKGROUND

PLAN VIEW

ELEVATION VIEW

4"x6" WOOD POSTS

GRADE

CONCRETE FOOTING

NOTES:

1. ALL VISIBLE SURFACE TO BE PRIMED

AND PAINTED. SURFACES NOT CALLED

OUT TO BE A SPECIFIC COLOR ARE TO

BE PAINTED WHITE.

2. SIGN TO BE ATTACHED TOGETHER

WITH WOOD SCREWS AND LAG BOLTS.

4"x6" POSTS

2"x4" FRAMING

SIGN FACE

48"

VA

U.S. Department of Veterans Affairs

This Project Has Worked Days

FRAMED SIGN PANEL - ALUMINUM SKIN

LAMINATED TO A WOOD CORE WITH

PHYSICALLY SEALED EDGES

TY

P

6" M

IN

TYP

6" MIN

TYP

6" MIN

VA BLUE (PANTONE 541) BACKGROUND

DEPARTMENT OF VETERAN AFFAIRS

LOGO - SURFACE APPLIED VINYL OR

SCREENED GRAPHICS - COLOR WHITE

SURFACE APPLIED VINYL OR SCREENED

GRAPHICS - COLOR RED

WHITE BACKGROUND

PLAN VIEW

ELEVATION VIEW

4"x4" WOOD POSTS

GRADE

CONCRETE FOOTING

NOTES:

1. ALL VISIBLE SURFACE TO BE PRIMED

AND PAINTED. SURFACES NOT CALLED

OUT TO BE A SPECIFIC COLOR ARE TO

BE PAINTED WHITE.

2. SIGN TO BE ATTACHED TOGETHER

WITH WOOD SCREWS AND LAG BOLTS.

4"x4" POSTS

2"x4" FRAMING

SIGN FACE

ZERO IN

ON SAFETY

00 0 Without a Lost Time Accident

THE LIFE YOU SAVE MAY BE YOUR OWN

General Contractors Firm Name CHANGEABLE NUMBERS

SURFACE APPLIED VINYL OR SCREENED

GRAPHICS - COLOR BLACK

architecture · engineering

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERS · SURVEYORS · CONSULTANTS ·

LANDSCAPE ARCHITECTS · LAND PLANNERS

298 VETERANS DRIVE

FOWLERVILLE,

MICHIGAN 48836

(OFFICE) 517-223-3512

(FAX) 517-223-9987

211 E. Water Street, Suite 213L

Kalamazoo, MI 49007 269.216.0222

VA STATION

Battle Creek VA Medical Center

5500 Armstrong Road

Battle Creek, MI 49037

Defining

EXCELLENCE

in the 21st Century

HEALTH

CARE

C :\R ev it\

\1

4_

A _m ic he lle .b ur ri.

rv t

5/

/2

:2 6:

A

M

39-I121

SIGNAGE DETAILS RENOVATE B39-2 WEST

FOR PATIENT PRIVACY

BATTLE CREEK, MI

515-20-102

05/20/2021 AAP CJA

100% BID DOCUMENTS190134

3" = 1'-0"

1 3.01

3" = 1'-0"

2 4.01

3" = 1'-0"

3 4.02

3" = 1'-0"

4 14.06

3" = 1'-0"

5 14.04

3" = 1'-0"

6 9.03

3" = 1'-0"

7 9.07

3" = 1'-0"

8 15.01 1/4" = 1'-0"

11 SIGNAGE MOUNTING DETAIL 2

SIGNAGE SCHEDULE

SIGNAGE SCHEDULE

ROOM

NO. ROOM NAME INSERT/TEXT

19 ELEVATOR 4 - TBD, 8 - "ELEVATOR"

35 STAIR STAIR GRAPHIC

36 STAIR STAIR GRAPHIC

208 DAY ROOM ROOM NUMBER, ROOM NAME

208A GROUP ROOM ROOM NUMBER, ROOM NAME

245 DAY ROOM ROOM NUMBER, ROOM NAME

245A…

This is the start of the file's text. The full file is on GovTribe.