This is a design drawing set for fencing and gates prepared by the State of Michigan Department of Technology, Management and Budget, State Facilities Administration, Design and Construction Division, under Contract Order No. 34660 (Consultant Job No. 17301.00). The drawings depict fencing and gate specifications for what appears to be a secure facility requiring chain-link fencing with razor ribbon additions. The project includes modifications to existing interior and exterior fencing, installation of detainer hook razor ribbon with 12-inch loop spacing, and construction of man gates measuring 4 feet by 6 feet 8 inches. The drawings were issued at the 50% review set stage on March 19, 2018, and at the bid set stage on May 11, 2018.
The specifications require all fabric, rails, posts, gates, and fittings to be hot-dipped galvanized steel with 2-inch diamond mesh chain-link fabric. All fencing must feature knuckled top and bottom configurations, with contractor-provided shop drawings and field-measured posts prior to construction. Gate frames must be constructed with weld cupped joints (fish mouth), with all welds required to be clean, uniform, continuous, and free of rust before galvanized finish application. The project encompasses multiple numbered sections detailing existing spool locations, grade levels, and specific razor ribbon installations across various interior and exterior fence locations, with additional details provided for typical man gate construction.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A-000
JKB
JFS
file no.
checked by drawn by consultant issue date index no.
contract order no.
34660 consultant job no.
17301.00 sheet title
472/17398.SMD
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
50% REVIEW SET 03/19/2018
BID SET 05/11/2018
C-100
JKB
JFS
N file no.
checked by drawn by consultant issue date index no.
contract order no.
34660 consultant job no.
17301.00 sheet title
472/17398.SMD
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
FENCING AND GATES NOTES
1. ALL FABRIC, RAILS, POSTS, GATES AND FITTINGS SHALL BE HOT-DIPPED GALVANIZED
STEEL WITH ZINC COATING, UNLESS NOTED OTHERWISE. ALL FABRIC SHALL BE 2"
DIAMOND MESH.
2. ALL CHAIN LINK FENCE, GATE AND COMPONENTS SHALL HAVE GALVANIZED FINISH.
3. ALL FENCING TO BE KNUCKLED TOP AND BOTTOM.
4. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL FENCING.
5. ALL FRAMES SHALL BE CONSTRUCTED IN SHOP. CONTRACTOR SHALL FIELD-MEASURE
POSTS PRIOR TO CONSTRUCTION.
6. ALL GATE FRAMES SHALL BE CONSTRUCTED WITH WELD CUPPED JOINTS (FISH MOUTH).
7. ALL WELDS SHALL BE CLEAN, UNIFORM, CONTINUOUS AND FREE OF RUST. GRIND
WELDS SMOOTH AND CLEAN PRIOR TO APPLICATION OF GALVANIZED FINISH.
GRADE
EXISTING INTERIOR
"A" FENCE
EXISTING EXTERIOR
"B" FENCE
EXISTING SPOOLS,
TYP
17'-8" x x x x x x x x x x x x x
12'-0" x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
EXISTING SPOOLS,
TYP
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
EXISTING SPOOLS,
TYP
x x x x x x x x x x x x x x x x x x x x x x x x x x
12'-0" x x x x x x x x x x x x x
ADD DETAINER HOOK
RAZOR RIBBON w/ 12"
LOOP SPACING 36
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
ADD DETAINER HOOK
RAZOR RIBBON w/ 12"
LOOP SPACING
ADD INSTABARRIER
RAZOR RIBBON w/ 12"
LOOP SPACING
APPROACH
GATOR
8'-4"
GRADE
EXISTING INTERIOR
"A" FENCE
EXISTING EXTERIOR
"B" FENCE
EXISTING SPOOLS,
TYP
17'-8" x x x x x x x x x x x x x
12'-0" x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
EXISTING SPOOLS,
TYP
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
EXISTING SPOOLS,
TYP
x x x x x x x x x x x x x
12'-0" x x x x x x x x x x x x x
ADD DETAINER HOOK
RAZOR RIBBON w/ 12"
LOOP SPACING 36
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
ADD DETAINER HOOK
RAZOR RIBBON w/ 12"
LOOP SPACING
ADD INSTABARRIER
RAZOR RIBBON w/ 12"
LOOP SPACING
APPROACH
GATOR
8'-4" x x x x x x x x x x x x x
REMOVE EXISTING
RAZOR RIBBON AND
REPLACE WITH
DETAINER HOOK
RAZOR RIBBON w/12"
LOOP SPACING
GRADE
EXISTING INTERIOR
FENCE
EXISTING SPOOLS,
TYP
x x x x x x x x x x x x x
12'-0" x x x x x x x x x x x x x
ADD DETAINER HOOK
RAZOR RIBBON w/12"
LOOP SPACING
x x x x x x x x x x x x x
GRADE
EXISTING INTERIOR
FENCE
EXISTING SPOOL
12'-0" x x x x x x x x x x x x x
ADD DETAINER HOOK
RAZOR RIBBON w/12"
LOOP SPACING
x x x x x x x x x x x x x x x x x x x x x x x x x x
ADD DETAINER HOOK
RAZOR RIBBON w/12"
LOOP SPACING
GRADE
EXISTING INTERIOR
FENCE
12'-0" x x x x x x x x x x x x x
ADD DETAINER HOOK
RAZOR RIBBON w/12"
LOOP SPACING
x x x x x x x x x x x x x
ADD DETAINER HOOK
RAZOR RIBBON w/12"
LOOP SPACING
x x x x x x x x x x x x x
GRADE
EXISTING INTERIOR
FENCE
EXISTING SPOOL
x x x x x x x x x x x x x
12'-0" x x x x x x x x x x x x x
ADD DETAINER HOOK
RAZOR RIBBON w/12"
LOOP SPACING
x x x x x x x x x x x x x
EXISTING SPOOL
x x x x x x x x x x x x x
EXISTING BUILDING
EXISTING SPOOL
x x x x x x x x x x x x x
NEW 31" DETAINER
HOOK RAZOR RIBBON
@ 12" OC
EXISTING STUN
FENCE
x x x x x x x x x x x x x
EXISTING BUILDING
EXISTING SPOOL31
x x x x x x x x x x x x x
NEW 31" DETAINER
HOOK RAZOR RIBBON
@ 12" OC
EXISTING STUN
FENCE
x x x x x x x x x x x x x
EXISTING BUILDING
x x x x x x x x x x x x x
EXISTING RAZOR
RIBBON REMOVED,
ADD NEW 31"
DETAINER HOOK
RAZOR RIBBON @ 12"
OC
EXISTING STUN
FENCE
x x x x x x x x x x x x x
6'-0"
6'-0"
12'-0""
6'-0"
1/4" PLATE STEEL
GUSSET (TYP.)
FENCE
SUPPORT POST (TYP)
4'-0" X 6'-8"
MAN GATE
6'-0"
STEEL PLATE
AROUND BOTTOM
OF GATE - REFER
TO DETAIL ON SITE.
10 TYPICAL MAN GATE DETAIL
SCALE: N.T.S.
x x x x x x x x x x x x x x x x x x x x x x x x x x
C-200
JKB
JFS
file no.
checked by drawn by consultant issue date index no.
contract order no.
34660 consultant job no.
17301.00 sheet title
472/17398.SMD
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
File details come from the government source that posted it. Updated .