This is a construction drawing document for fencing and gates prepared by the State of Michigan Department of Technology, Management and Budget, State Facilities Administration, Design and Construction Division, for a project at Lakeland (Contract Order No. 45730, Consultant Job No. 17294.00). The drawing set includes a 50% review set dated March 19, 2018, and a bid set dated May 11, 2018. The project requires the installation of chain link fencing with specific modifications including hot-dipped galvanized steel fabric with 2-inch diamond mesh, knuckled top and bottom configurations, and razor ribbon detainer hooks and InstaBarrier razor ribbon with 12-inch loop spacing. The work involves both existing interior "A" fence and exterior "B" fence installations, with specifications for 16-foot and 12-foot sections, existing spools, and gator-style gates measuring 6 feet 8 inches in height. Contractors must provide shop drawings and field-measure posts prior to construction, with all frame construction completed in the shop using weld-cupped joints and maintaining clean, continuous welds that are ground smooth before galvanized finishing.

The specifications mandate that all fabric, rails, posts, gates, and fittings be hot-dipped galvanized steel with zinc coating unless otherwise noted, with all chain link components featuring galvanized finish. The contractor is responsible for ensuring all welds are clean, uniform, and continuous, free of rust, with smooth grinding prior to galvanized finish application. No pricing information, set-asides, funding sources, or contract term details are provided in this technical drawing document.

View the file

Other files

File Type Posted
Addendum 2 Bid Pack 3B - SIGMA.pdf PDF
Drawings - 3B Gus Harrison.pdf PDF
LEIN Request REV 04-2018 Bid Pkg 3.pdf PDF
Specifications - 3B 17398.pdf PDF
Advertisement Bid Pkg 3B 17398.pdf PDF
Drawings - 3B Egeler.pdf PDF
Addendum 1 Bid Pack 3B.pdf PDF
Addendum 3 Bid Pack 3B.pdf PDF
Drawings - 3B Parnall.pdf PDF
Drawings - 3B Thumb.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A-000

JKB

JFS

file no.

checked by drawn by consultant issue date index no.

contract order no.

45730 consultant job no.

17294.00 sheet title

472/17399.SMD

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

50% REVIEW SET 03/19/2018

BID SET 05/11/2018

file no.

checked by drawn by consultant issue date index no.

contract order no.

45730 consultant job no.

17294.00 sheet title

472/17399.SMD

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

50% REVIEW SET 03/19/2018

BID SET 05/11/2018

C-100

JKB

JFS

N

FENCING AND GATES NOTES

1. ALL FABRIC, RAILS, POSTS, GATES AND FITTINGS SHALL BE HOT-DIPPED GALVANIZED

STEEL WITH ZINC COATING, UNLESS NOTED OTHERWISE. ALL FABRIC SHALL BE 2"

DIAMOND MESH.

2. ALL CHAIN LINK FENCE, GATE AND COMPONENTS SHALL HAVE GALVANIZED FINISH.

3. ALL FENCING TO BE KNUCKLED TOP AND BOTTOM.

4. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL FENCING.

5. ALL FRAMES SHALL BE CONSTRUCTED IN SHOP. CONTRACTOR SHALL FIELD-MEASURE

POSTS PRIOR TO CONSTRUCTION.

6. ALL GATE FRAMES SHALL BE CONSTRUCTED WITH WELD CUPPED JOINTS (FISH MOUTH).

7. ALL WELDS SHALL BE CLEAN, UNIFORM, CONTINUOUS AND FREE OF RUST. GRIND

WELDS SMOOTH AND CLEAN PRIOR TO APPLICATION OF GALVANIZED FINISH.

GRADE

EXISTING INTERIOR

"A" FENCE

EXISTING EXTERIOR

"B" FENCE

EXISTING SPOOLS,

TYP

16'-0" x x x x x x x x x x x x x

12'-0" x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

EXISTING SPOOLS,

TYP

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

EXISTING SPOOLS,

TYP

x x x x x x x x x x x x x x x x x x x x x x x x x x

12'-0" x x x x x x x x x x x x x

ADD DETAINER HOOK

RAZOR RIBBON w/ 12"

LOOP SPACING 36

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

ADD DETAINER HOOK

RAZOR RIBBON w/ 12"

LOOP SPACING

ADD INSTABARRIER

RAZOR RIBBON w/ 12"

LOOP SPACING

APPROACH

GRADE

EXISTING INTERIOR

"A" FENCE

EXISTING EXTERIOR

"B" FENCE

EXISTING SPOOLS,

TYP

16'-0" x x x x x x x x x x x x x

12'-0" x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

EXISTING SPOOLS,

TYP

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

EXISTING SPOOLS,

TYP

x x x x x x x x x x x x x

12'-0" x x x x x x x x x x x x x

ADD DETAINER HOOK

RAZOR RIBBON w/ 12"

LOOP SPACING 36

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

ADD DETAINER HOOK

RAZOR RIBBON w/ 12"

LOOP SPACING

ADD INSTABARRIER

RAZOR RIBBON w/ 12"

LOOP SPACING

APPROACH

x x x x x x x x x x x x x

6'-8"

GATOR

6'-8"

GATOR

C-200

JKB

JFS

file no.

checked by drawn by consultant issue date index no.

contract order no.

45730 consultant job no.

17294.00 sheet title

472/17399.SMD

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

50% REVIEW SET 03/19/2018

BID SET 05/11/2018

File details come from the government source that posted it. Updated .