Drawing 90-E-210.pdf
PDF 314 KB Posted
- Solicitation number
- 36E77620B0008_0003
About this file
This drawing package pertains to a telecommunications infrastructure upgrade project at the Tucson VA Medical Center campus. The project involves installing new conduits and fiber optic cabling to connect communication rooms in buildings 38, 67 and provide connectivity between existing manholes and pull boxes. The scope of work includes splicing new cables to existing lines, coordinating cutovers, and removing old infrastructure once the new system is operational. The contractor will be provided conduits and vaults to facilitate their work. The project aims to modernize the facility's voice and data networking through an improved pathway and cabling plan as depicted in the diagrams.
The related federal contract solicitation is for the Expand Mental Health Clinic Building 90 project in Tucson, Arizona. It is being conducted by the Department of Veterans Affairs Headquarters and provides a final technical questions log and attachments as an amendment to the original solicitation.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COMM
ROOM
#1239 (E)
PB
(N)
(1) 4"C WITH 600 PAIR COPPER CABLE & 144 STRAND SINGLE MODE FIBER,
AND (1)4"C WITH (1)48 STRAND SINGLE MODE FIBER
(1) 48 STRAND MULTIMODE FIBER,
(1) 25 PAIR COPPER (PE-89),
(1)6 PAIR COPPER
(N)
MH
(E)
MH-6
(E)
MH
EXISTING (1) 600 PAIR
COPPER TO BLDG #6
(E)
MH
(E)
PB
67 B-38 BASEMENT TELECOMM.
ROOM. #0A01.
KEY NOTES
REFER TO KEY NOTE #10 ON SHEET 90-E-209.
REFER TO KEY NOTE #13 ON SHEET 90-E-209. COORDINATE WITH VA
FOR THE MAN-HOLE NUMBER.
REFER TO KEY NOTE #6 ON SHEET 90-E-209. CONFIRM THE MAN-HOLE
NUMBER WITH VA.
EXISTING MAN-HOLE #5 TO BE USED FOR SPLICING OF EXISTING OR
NEW CABLE RUNS.
EXISTING MANHOLE #13.
EXISTING PULL BOX IN FRONT OF BUILDING B67.
MANHOLE "MH-5" HAS:
(1) BLUE INNER DUCT WITH (1) SM 48 STRAND & (1) MM 48 STRAND
(1) RED INNER DUCT WITH 25 PAIR COPPER (PE-89),
(1) WHITE INNER DUCT WITH 6 PAIR COPPER CABLE.
EXISTING PATHWAY FROM MH-13 TO PULL BOX ( SEE NOTE #6 ABOVE
WITH:
a) 144 STRAND SINGLE MODE FIBER WHICH CAN BE EITHER
SPLICED IN FIRE RISER ROOM IN B67 (BASEMENT) WITH
EXISTING CABLE FROM B38 OR NEW CABLE PULLED UPTO ROOM
#0A01-38
b) (1) 48 STRAND SINGLE MODE & (1) 48 STRAND MULTIMODE IN
BLUE INNER DUCT SPLICED IN MH-5 WITH EXISTING CABLING
FROM MH-4 IN FRONT OF BLDG B-4 OR NEW CABLE FROM MH-6
THRU MH-13 TO BASEMENT IN BLDG. B67 FOR SPLICING OR
RUNNING ALL THE WAY TO ROOM #0A01-38.
c) (1) 25 PAIR COPPER (PE-89) IN RED INNER DUCT TO BE SPLICED
IN FIRE RISER ROOM IN BASEMENT ,B67 WITH EXISTING WIRING
FROM ROOM 157 IN B67 OR PULL NEW WIRE ALL THE WAY TO
B67,ROOM 157.
d) (1) 6 PAIR COPPER IN WHITE INNER DUCT TO BE SPLICED IN FIRE
RISER ROOM WITH EXISTING FROM B38 OR RUN NEW WIRE ALL
THE WAY TO ROOM 0A01-38 IN B38.
ALL EXISTING CABLING COMING FROM ROOM #0A01-38 IN BLDG 38 CAN
EITHER BE SPLICED IN THE FIRE RISER ROOM OF BLDG -67, BASEMENT
OR RUN NEW WIRE ALL THE WAY TO THE TERMINATION POINT AS
DESCRIBED IN THE NOTE ABOVE.
GOVERNMENT WILL PROVIDE 800'-0" OF 4" CONDUIT AND MANHOLE/PULL
BOX OF 3'-0"W X 4'-0"L X 3'-6" H FOR CONTRACTOR'S USE.
SPLICING/FUSION SPLICING OF
NEW CABLES FROM ROOM #1239 &
(E) CABLES FROM MH-13 TO BE
DONE IN MH-5
(N)
(N)
5 6
(E)(1) 4"C WITH (1) 600 PAIR COPPER AND
(E) (1) 48 STRAND SM,
(1) 48 STRAND MM IN BLUE INNER DUCT.
COMM
ROOM
#1239 (E)
E(2) 4"C WITH
600 PAIR COPPER CABLE AND 144 STRAND SINGLE MODE FIBER IN (1)4"C
& (1) 48 STRANDS SINGLE MODE, (1) 48 STRANDS MULTI MODE
(1) 12 STRANDS SINGLE MODE,24 STRAND 62.5 MULTI MODE HYBRID
(1) 25 PAIR COPPER (PE-89), AND
(1) 6 PAIR COPPER, ALL IN 4"C
(E)
MH
TO PULL BOX BLDG. #67
UGF TO POLE MTD.CAMERA IN PARKING LOT
TO BE REMOVED AND PROTECTED FOR
RE-INSTALLTION
TO MH-5
CCTV
CCTV
KEY NOTES
EXISTING CONDUIT AND CABLING TO BE REMOVED ONCE THE NEW
PATHWAY & CABLING HAS BEEN INSTALLED AND CONNECTED
SUCCESSFULLY.
EXISTING (1) 600 PAIR COPPER CABLE FROM MH-13 TO MH-5 IN (E)
CONDUIT TO BLDG. 6. & (1) 48 STRANDS SM FIBER AND (1) 48 STRANDS
MM FIBER IN BLUE INNER DUCT TO ROOM 0A01-38 IN BLDG. 38
BASEMENT.
a) EXISTING 144 STRAND TO ROOM 0A01 -38 IN BLDG. B38
BASEMENT THRU PULL BOX (SEE NOTE #6 IN DETAIL
#2/90-E-210). ALSO REFER TO NOTE #8(a) IN DETAIL #2.
b) EXISTING (1) 12 STRANDS SINGLE MODE AND (1) 24 STRANDS
62.5 MULTIMODE IN ORANGE DUCT TO ROOM 0A01-38 IN
BLDG.38- TO BE REMOVED.
HOWEVER (4) STRANDS ON 62.5 MULTIMODE & (1) STRAND
IN SINGLE MODE ( FOR TV SIGNAL) TO BE MOVED TO NEW
FIBER BEFORE CONSTRUCTION COMMENCES. ( CONTRACTOR
TO COORDINATE WITH VA.)
c) EXISTING (1) 25 PAIR COPPER (PE-89) IN RED INNER DUCT TO
ROOM #157 IN BLDG.B67 THRU PULL BOX. ( SEE NOTE #6 IN
DETAIL 2/90-E-210.
d) EXISTING (1) 6 PAIR COPPER IN WHITE INNER DUCT TO ROOM
0A01-38 IN BLDG. B38 THRU PULL BOX ( SEE NOTE #6 IN DETAIL
2/90-E-210.
UGF
(N)
(N)
(1) 4"C WITH 600 PAIR COPPER CABLE & 144 STRAND SINGLE MODE FIBER,
AND (1)4"C WITH (1)48 STRAND SINGLE MODE FIBER
(1) 48 STRAND MULTIMODE FIBER,
(1) 25 PAIR COPPER (PE-89),
(1)6 PAIR COPPER
(1) 4"C WITH 600 PAIR COPPER CABLE & 144 STRAND SINGLE MODE FIBER,
AND (1)4"C WITH (1)48 STRAND SINGLE MODE FIBER
(1) 48 STRAND MULTIMODE FIBER,
(1) 25 PAIR COPPER (PE-89),
(1)6 PAIR COPPER
(N) 144 STRANDS SINGLE MODE FIBER IN (E) 4" C (EMPTY),
(N) (1) 25 PAIR COPPER (PE-89) AND
(N) (1) 6 PAIR COPPER
(N) (1)-4"C WITH 600 PAIR COPPER
(N) 4"C-(1) SM 48 STRANDS & (1) MM 48
STRANDS IN BLUE INNER DUCT AS ONE
PULL
(E)
MH
4 B-38 BASEMENT TELECOMM.
ROOM. #0A01.
(E)BLUE INNER DUCT WITH (1) SM 48
STRAND & (1) MM 48 STRAND
ONE LINE DIAGRAM FOR VOICE/DATA SYSTEM (EXISTING)
NTS1
8-
EX
PA
N D
M
EN
TA
L
H
EA
LT
H
C
LI
N
IC
, B
BI
D S
ET
STAMP
SAVAHCS, TUCSON, AZ 85723
678-329
12-06-2019
315 ARDEN AVE, SUITE 26, GLENDALE, CA 91203
www.schwabeng.com Project No.: S60204180.00
U.S. Department of Veterans Affairs
Bid Set
ONE LINE DIAGRAM FOR
VOICE/DATA SYSTEM
VB RD 90-E-210
RFI - 17 11/20/2020
ONE LINE DIAGRAM FOR VOICE/DATA SYSTEM (NEW PATHWAY WITH CABLING)
NTS2
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231, OCT 1978
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Office of
AutoCAD SHX Text Facilities
AutoCAD SHX Text Management
AutoCAD SHX Text F
AutoCAD SHX Text Building Number
AutoCAD SHX Text Approved: Chief of Staff
AutoCAD SHX Text Approved: Assistant Director
AutoCAD SHX Text Approved: Chief, Facilities Management
AutoCAD SHX Text Approved: Associate Director - Patient Care Services
AutoCAD SHX Text Location
AutoCAD SHX Text Approved: Director
AutoCAD SHX Text Approved: Associate Director
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Checked
AutoCAD SHX Text Project Title
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text Project No.
AutoCAD SHX Text Drawn
AutoCAD SHX Text Date
AutoCAD SHX Text
EXPAND MENTAL HEALTH
AutoCAD SHX Text
CLINIC, B90
AutoCAD SHX Text
ARCHITECT/ENGINEERS/CONSULTANTS:
| Ele plans today.pdf |
| Sheets and Views |
| 90-E-109 - ELECTRICAL DEMO - SITE PLAN-90-ED-109 |
| 90-E-209 - ELECTRICAL NEW - SITE PLAN-90-E-209 |
| 90-E-210 - ONE LINE OUTLINE FOR FIBER CABLE SITE PLAN ADDED-90-E-210 |
File details come from the government source that posted it. Updated .