Drawing_3533s-18-E-E54.pdf
PDF 676 KB Posted
- Attached to
- CRCGV-02 Material and Equipment Specifications
- Solicitation number
- 69CRC-S2782
- Issued by
- Clark County, Fish Springs CDP, Nevada
About this file
This document contains information related to a state and local contract opportunity for the CRCGV-02 Material and Equipment Specifications project, involving the Nevada state government. The project requires the provision of manufacturer-designed structural steel framework for mounting and connecting all equipment at substation sites, in accordance with the attached drawings. The scope includes arranging all circuits and static masts as shown on the plans. No specific quantities, response dates, or award information is provided in the document.
The document does not include details on pricing terms, set-asides, incumbents, funding requirements, or other salient commercial information. It appears to be focused on the technical specifications and drawings for the required substation structures and equipment.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| CRCGV-02_Material and Equipment_Bid Contract.docx | DOCX document | |
| Drawing_3533s-18-E-E161.pdf | ||
| DRAWINGS~2.pdf | ||
| Drawing_3533s-18-E-E51.pdf | ||
| Drawing_3533s-18-E-E50.pdf | ||
| Drawing_3533s-18-E-E52.pdf | ||
| 33 72 73 - MATERIAL AND EQUIPMENT SPECIFICATIONS.pdf | ||
| Quote Instructions.pdf | ||
| Drawing_3533s-18-E-E53.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
230kV
CKT BKR
2000A
(FUTURE)
VOLTAGE TRANSFORMER
CURRENT TRANSFORMER
CIRCUIT BREAKER
MOTOR OPERATOR
GROUP OPERATED SWITCH
FUSED DISCONNECT SWITCH
SWITCH
TRANSFORMER
M
DEVICE LEGEND
QV1A
230kV LINE CT
50:5 SR
50:5
H2
H3H1
X2
X3
X0X1
T1
POWER TRANSFORMER
10/12.5MVA
230-12.47/7.2kV
Z=XX%
VV1A
230kV LINE VT
138,000-115/69V 1200/2000:1
1200:5MR
1200:5
4022FEEDER #1
CENTER BREAK SWITCH
KW40B
DISTRIBUTION
TRANSFORMER
12.47-4.16/2.4KV
10 MVA
CT1 T2
1200:5MR
1200:5
15kV
CKT BKR
1200A
1200:5MR
500:5
1200:5MR
SHORTED
SCADA
15kV, VB
SWITCH
1200A
SA4
7.65kV
MCOV
X
KW40A1
STATION SERVICE
TRANSFORMER
25KVA
7,200-120/240V
TO
ATS
(SEL-751)
51P1
600:5MR
SHORTED
600:5MR
SHORTED
X0
600:5MR
600:5
H
600:5MR
SHORTED
600:5MR
SHORTED
SA2
140kV
MCOV
2000:5MR
SHORTED
2000:5MR
SHORTED
230kV
CKT BKR
2000A
1200:5MR
1200:5
2000:5MR
500:5
230kV, VB
SWITCH
1200A
230kV LINE TO
NVE PROSPECTOR
SA1
140kV
MCOV
230kV, CBV
SWITCH
1200A(ION)
PM-L
VV1A4
VV1A3
VV1A2
VV1A1
H2
H3H1
X2
X3
X0X1
T2
POWER TRANSFORMER
10/12.5MVA
230-12.47/7.2kV
Z=XX%
1200:5MR
1200:5
5022FEEDER #2
KW50B
DISTRIBUTION
TRANSFORMER
12.47-4.16/2.4KV
10 MVA 1200:5MR
1200:5
15kV
CKT BKR
1200A
1200:5MR
500:5
1200:5MR
SHORTED
15kV, VB
SWITCH
1200A
SA5
7.65kV
MCOV
X
KW50A1
STATION SERVICE
TRANSFORMER
25KVA
7,200-120/240V
TO
ATS
51P2
600:5MR
SHORTED
600:5MR
SHORTED
X0
600:5MR
600:5
H
600:5MR
SHORTED
600:5MR
SHORTED
SA3
140kV
MCOV
2000:5MR
SHORTED
2000:5MR
SHORTED
230kV
CKT BKR
2000A
1200:5MR
1200:5
2000:5MR
500:5
230kV, VB
SWITCH
1200A
FUTURE
230kV LINE
(FUTURE)
230kV, CBV
SWITCH
1200A
87T1S
87T1P
(SEL-487E)
(SEL-487E)
ST
ST
V
VV1A2(3)
U
V
VV1A4(3)
U-IN
U-OUT
63X149T1 120°
26Q1 110°
71Q1
LOW
86T1
LOR
TRIP 482 TC1
TRIP 482 TC2
BLK CLS 482
TRIP 4022 TC1
TRIP 4022 TC2
BLK CLS 4022
87T2S
87T2P
(SEL-487E)
(SEL-487E)
ST
ST
V
VV1A2(3)
U
V
VV1A4(3)
U-IN
U-OUT
63X149T1 120°
26Q1 110°
71Q1
LOW
86T2
LOR
TRIP 582 TC1
TRIP 582 TC2
BLK CLS 582
TRIP 5022 TC1
TRIP 5022 TC2
BLK CLS 5022
230kV, VB
SWITCH
1200A
DEVICE
NAME FUNCTIONS RELAY
87T1P/S 50/51P, 50/51N, 87, 50/86BF SEL-487E
87T2P/S 50/51P, 50/51N, 87, 50/86BF SEL-487E
51P1
51P2 50/51P SEL-751
86T1
86T2 LOCK-OUT RELAY 78PB05D
52CS CONTROL SWITCH 24PC38D
43LR LOCAL REMOTE SWITCH 78PB02D
26Q TEMPERATURE SWITCH TBD BY VENDOR
49T TEMPERATURE MONITOR TBD BY VENDOR
63X PRESSURE RELAY TBD BY VENDOR
71Q LIQUID LEVEL RELAY TBD BY VENDOR
52CS
43LS
86T1 51P1
SCADA
52CS
86T1 51P1
51P1
SCADA
52CS
86T1
(SEL-751)
CT1 T2
SCADA
52CS
43LS
86T2 51P2
SCADA
52CS
86T2 51P2
51P2
SCADA
52CS
86T2
CT1 T2
SCADA
52CS
43LS
87T1P 86T1
SCADA
52CS
87T1S 86T1
87T1P 87T1S
SCADA
52CS
86T1
CT1 T2
SCADA
52CS
43LS
87T2P 86T2
SCADA
52CS
87T2S 86T2
87T2P 87T2S
SCADA
52CS
86T2
TRIP 482 TC2
TRIP 582 TC2
TRIP 482 TC1
TRIP 582 TC1
(ION)
PM-N
230kV, VB
SWITCH
1200A
(FUTURE)
D
ES
IG
N
S U
BM
IT
TA
L
- P R
EL
IM
IN
AR
Y
SU
BM
IT
TA
L
N O
T
FO
R C
O N
ST
R
U C
TI
O
N
CRC
METERING
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
R
EV
IS
IO
N S:
DRAWING/NUMBER
SHEET OF
COMMIT:
PROJECT:
SC
AL
E
VE
R
IF
Y
SC
AL
E 1/
1/
BA
R
R
EP
R
ES
EN
TS
O N
E
AN
D O
N E-
H
AL
F
IN
C H
ES
O
N O
R
IG
IN
AL
V
IA
A U
ST
I P
AR
KW
AY
S
U
IT
E
LA
S
VE
G
AS
N
EV
AD
A
(7
) 9
-6
3533S
010717
E54
SH
AH
N
AW
AZ
A
N
JA
N
ZA
FA
R A
SH
R
AF
I
G
AR
N
ET
V
AL
LE
Y
W
AT
ER
S
YS
TE
M
AP
EX
PU
M
PI
N
G S
TA
TI
O N
S
IT
E
AP
EX
S U
BS
TA
TI
O
N R
EL
AY
IN
G
O N
E
LI
N E
D
IA
G R
AM
NT
S
NVE
METERING