DRAFT_Attachment_2.pdf

PDF 622 KB Posted

Attached to
AV Equipment Upgrade for Split Conference Rooms
Solicitation number
N6426726Q5012
Issued by

About this file

This document is a technical specification table for Team Submarine Conference Room Upgrades at CLB TANC, detailing the AFSM (Audio/Visual Switch Matrix) load configuration in Rev 12. The specification covers two primary conference rooms (201/4W-333 and 201/4W-334) with architectural boxes numbered 0242-04 (AF1), 0242-05 (AF7), 0242-02 (AF8), and 0242-06 (AF14), each requiring specific networking, audio-visual, and power infrastructure upgrades.

The technical requirements include multiple CAT6 network connections with RJ-45 connectors supporting VOIP, vIPer, and itinerant laptop connectivity across classified (SIPR) and unclassified (NIPR) networks, with designations for NNPI and non-NNPI data. Audio-visual specifications call for HD video transmission via CAT6 connections using 4KZ transceiver technology, 70.7V analog audio distribution to overhead speakers, and DMPS3 video switching to multiple display systems including 85-inch and 65-inch LSDs. Each architectural box requires 120 VAC 20 Amp power distribution via 1-gang or 2-gang NEMA 20 connectors, with hard disconnect surfaces required at most connection points per integrator specifications. The document indicates support for Crestron control systems, Poly RPG 500 videoconferencing equipment, and NMCI network connectivity, with responsibility assignments split between Facilities and Integrator for installation and configuration.

View the file

Other files

File Type Posted
DRAFT_SOW_N6426726Q5012.pdf PDF
DRAFT_CDRL_N6426726Q5012_Redacted.pdf PDF
DRAFT_Attachment_1.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Table 3. Team Submarine Conference Room Upgrades - CLB TANC Split AFSM Load Rev 12

Arch. Box No.

Arch. Box

Type Arch. Box Port No.

Location Cable Function Cable Type Connector Type Hard Disconnect Surface Required

Remarks

0242-04 (AF1) AFSM 201/4W-333 - Center, conference table D1 VOIP NIPR NTWK CAT6 RJ-45 Y Facilities D2 vIPer NIPR NTWK CAT6 RJ-45 Y Facilities D3 Itinerant Laptop non-NNPI NIPR NTWK CAT6 RJ-45 Y Facilities P1 Itinerant Laptop U-NNPI NIPR NTWK CAT6 RJ-45 Y Facilities

- Power 120 VAC 20 Amp 2-gang NEMA 20 N Existing

AV1 AFSM 201/4W-333 - Center, conference table AV-only AFSM D1 Itinerant Laptop U-NNPI Video CAT6 RJ-45 Y Integrator, HD TXC 4KZ 101 D2 Itinerant Laptop non-NNPI Video CAT6 RJ-45 Y Integrator, HD TXC 4KZ 101 D3 UC-SB1-CAM Room USB Webcam CAT6 RJ-45 Y Integrator, USB-EXT-3-LOCAL P1 Crestron TS-1070-GV-B-S to DMPS3 CAT6 RJ-45 Y Integrator

- Power 120 VAC 20 Amp 2-gang NEMA 20 N Existing, Panel RP-41-8

AV2 Wall mount 201/4W-333 - West wall, RPG/Studio X50

2.a. RPG 500 SIPR VTC VLAN NTWK FL SC Y NMCI Network Support, FL-Cu Converter

- Power 120 VAC 20 Amp 1-gang NEMA 20 N Adjacent 120 VAC 20 Amp Duplex

AV3 Wall mount 201/4W-333 - NW corner, DMPS3 Equipment Cabinet

3.a. 70.7 V Audio Analog to Ovhd. Speakers Tw pair 20 Ga. Phoenix Y Integrator

3.b. DMPS3 Video to Local Presentation 85" LSD -

AV5

CAT6 RJ-45 Y Integrator, HD TXC 4KZ 101

3.c. DMPS3 Video to Teams 65" LSD - AV6 CAT6 RJ-45 Y Integrator, HD TXC 4KZ 101

3.d. DMPS3 Video to SKVM Input 1 - Internal HDMI HDMI N Integrator, connection internal to equip. rack

3.e. DMPS3 Control to Crestron TS-1070-GV-B-S

AV1 - AFSM

CAT6 RJ-45 Y Integrator, DM link

3.f. DMPS3 Control to Crestron TS-1070-GV-B-S AV7 - Side

CAT6 RJ-45 Y Integrator, DM link

3.g. AV1 - AFSM Itinerant Laptop U-NNPI Video to

DMPS3

CAT6 RJ-45 Y Integrator, HD RXC 4KZ 101

3.h. AV1 - AFSM Itinerant Laptop non-NNPI Video to DMPS3

CAT6 RJ-45 Y Integrator, HD RXC 4KZ 101

3.i. AV7 - Side Itinerant Laptop U-NNPI Video to

DMPS3

CAT6 RJ-45 Y

Integrator, HD RXC 4KZ 101

3.j. AV7 -Side Itinerant Laptop non-NNPI Video to

DMPS3

CAT6 RJ-45 Y Integrator, HD RXC 4KZ 101

3.k. DMPS3 333 System Cross-connect to DMPS3 334 - Internal - CC1

CAT6 RJ-45 Y Integrator, DM out to DM in

3.l. DMPS3 334 System Cross-connect to DMPS3 333 - Internal - CC2

CAT6 RJ-45 Y Integrator, DM out to DM in

- Power 120 VAC 20 Amp 2-gang NEMA 20 N Adjacent 120 VAC 20 Amp Duplex

AV4 Wall mount 201/4W-333 - NW corner, Driver Workstation, SKVM

4.a. Classified Workstation SIPR NTWK FL SC Y NMCI Network Support, FL-Cu Converter

- Power 120 VAC 20 Amp 2-gang NEMA 20 N Adjacent 120 VAC 20 Amp Duplex

AV5 Wall mount 201/4W-333 - North wall, center, Local Presentation 85" LSD;

Crestron UC-SB1-CAM Room USB

5.a. DMPS3 Video to 85" LSD CAT6 RJ-45 Y Integrator, HD RXC 4KZ 101

5.b. UC-SB1-CAM Room USB Webcam Video out to conference table

CAT6 RJ-45 Y Integrator, USB-EXT-3-REMOTE

- Power 120 VAC 20 Amp 2-gang NEMA 20 N Adjacent 120 VAC 20 Amp Duplex

Table 3. CLB TANC Split AFSM Load Rev 13 02062026.xlsx

DRAFT

Arch. Box

Type Arch. Box Port No.

Location Cable Function Cable Type Connector Type Hard Disconnect Surface Required

Remarks

AV6 Wall mount 201/4W-333 - East wall, center, Teams Presentation 65" LSD

6.a. DMPS3 Video to 65" LSD CAT6 RJ-45 Y Integrator, HD RXC 4KZ 101 6.b. Power 120 VAC 20 Amp 1-gang NEMA 20 N Adjacent 120 VAC 20 Amp Duplex

[0242-05] (AF7) Wall mount 201/4W-333 - North wall, Side Wall Network Connections Presumptive I/O numbering

D1 VOIP NIPR NTWK CAT6 RJ-45 Y Facilities D2 vIPer NIPR NTWK CAT6 RJ-45 Y Facilities D3 Itinerant Laptop non-NNPI NIPR NTWK CAT6 RJ-45 Y Facilities P1 Itinerant Laptop U-NNPI NIPR NTWK CAT6 RJ-45 Y Facilities

- Power 120 VAC 20 Amp 2-gang NEMA 20 N Integrator

AV7 Wall mount 201/4W-333 - North Wall, Side Wall AV Connections

7.a. Itinerant Laptop U-NNPI Video CAT6 RJ-45 Y Integrator, HD TXC 4KZ 101 7.b. Itinerant Laptop non-NNPI Video CAT6 RJ-45 Y Integrator, HD TXC 4KZ 101 7.c. UC-SB1-CAM Room USB Webcam CAT6 RJ-45 Y Integrator, USB-EXT-3-LOCAL 7.d. Crestron TS-1070-GV-B-S to DMPS3 CAT6 RJ-45 Y Integrator

- Power 120 VAC 20 Amp 2-gang NEMA 20 N Integrator 0242-02 (AF8) AFSM 201/4W-334 - Center, conference table

D1 VOIP NIPR NTWK CAT6 RJ-45 Y Facilities D2 vIPer NIPR NTWK CAT6 RJ-45 Y Facilities D3 Itinerant Laptop non-NNPI NIPR NTWK CAT6 RJ-45 Y Facilities P1 Itinerant Laptop U-NNPI NIPR NTWK CAT6 RJ-45 Y Facilities

- Power 120 VAC 20 Amp 2-gang NEMA 20 N Existing

AV8 AFSM 201/4W-334 - Center, conference table AV-only AFSM D1 Itinerant Laptop U-NNPI Video CAT6 RJ-45 Y Integrator, HD TXC 4KZ 101 D2 Itinerant Laptop non-NNPI Video CAT6 RJ-45 Y Integrator, HD TXC 4KZ 101 D3 UC-SB1-CAM Room USB Webcam CAT6 RJ-45 Y Integrator, USB-EXT-3-LOCAL P1 Crestron TS-1070-GV-B-S to DMPS3 CAT6 RJ-45 Y Integrator

- Power 120 VAC 20 Amp 2-gang NEMA 20 N Existing, Panel RP-41-2

AV9 Wall mount 201/4W-334 - West wall, Poly RPG/Studio X50

9.a. RPG 500 SIPR VTC VLAN NTWK FL SC Y NMCI Network Support, FL-Cu Converter

- Power 120 VAC 20 Amp 1-gang NEMA 20 N Adjacent 120 VAC 20 Amp Duplex

AV10 Wall mount 201/4W-334 - SW corner, DMPS3 Equipment Cabinet - Internal

10.a. 70.7 V Audio Analog to Ovhd. Speakers Tw pair 20 Ga. Phoenix Y Integrator

10.b. DMPS3 Video to Local Presentation 85" LSD -

AV12

CAT6 RJ-45 Y Integrator, HD TXC 4KZ 101

10.c. DMPS3 Video to Teams 65" LSD - AV13 CAT6 RJ-45 Y Integrator, HD TXC 4KZ 101

10.d. DMPS3 Video to SKVM Input 1 - Internal HDMI HDMI N Integrator, connection internal to equip. rack

10.e. DMPS3 Control to Crestron TS-1070-GV-B-S -

AV8 AFSM

CAT6 RJ-45 Y Integrator, DM link

10.f. DMPS3 Control to Crestron TS-1070-GV-B-S - AV14 Side

CAT6 RJ-45 Y Integrator, DM link

10.f. AV8- AFSM Itinerant Laptop U-NNPI Video to

DMPS3

CAT6 RJ-45 Y Integrator, HD RXC 4KZ 101

10.g. AV8 - AFSM Itinerant Laptop non-NNPI Video to DMPS3

CAT6 RJ-45 Y Integrator, HD RXC 4KZ 101

Arch. Box

Type Arch. Box Port No.

Location Cable Function Cable Type Connector Type Hard Disconnect Surface Required

Remarks

10.h. AV14 - Side Itinerant Laptop U-NNPI Video to

DMPS3

CAT6 RJ-45 Y Integrator, HD RXC 4KZ 101

10.i. AV14 - Side Itinerant Laptop non-NNPI Video to

DMPS3

CAT6 RJ-45 Y Integrator, HD RXC 4KZ 101

10.j. DMPS3 333 System Cross-connect to DMPS3 334 - Internal - CC1

CAT6 RJ-45 Y Integrator, DM out to DM in

10.k. DMPS3 334 System Cross-connect to DMPS3 333 - Internal - CC2

CAT6 RJ-45 Y Integrator, DM out to DM in

- Power 120 VAC 20 Amp 2-gang NEMA 20 N Adjacent 120 VAC 20 Amp Duplex

AV11 Wall mount 201/4W-334 - SW corner, Driver Workstation, SKVM

11.a. Classified Workstation SIPR NTWK FL SC Y NMCI Network Support, FL-Cu Converter

- Power 120 VAC 20 Amp 2-gang NEMA 20 N Adjacent 120 VAC 20 Amp Duplex

AV12 Wall mount 201/4W-334 - South wall, center, Local Presentation 85" LSD;

Crestron UC-SB1-CAM Room USB

12.a. DMPS3 Video to 85" LSD CAT6 RJ-45 Y Integrator, HD RXC 4KZ 101

12.b. UC-SB1-CAM Room USB Webcam Video out to Conference table

CAT6 RJ-45 Y Integrator, USB-EXT-3-Remote

- Power 120 VAC 20 Amp 2-gang NEMA 20 N Adjacent 120 VAC 20 Amp Duplex

AV13 Wall mount 201/4W-334 - East wall, center, Teams Presentation 65" LSD

13.a. DMPS3 Video to 65" LSD CAT6 RJ-45 Y Integrator, HD RXC 4KZ 101

- Power 120 VAC 20 Amp 1-gang NEMA 20 N Adjacent 120 VAC 20 Amp Duplex

[0242-06] (AF14) Wall mount 201/4W-334 - South Wall, Side Wall Network Connections Presumptive I/O numbering

D1 VOIP NIPR NTWK CAT6 RJ-45 Y Facilities D2 vIPer NIPR NTWK CAT6 RJ-45 Y Facilities D3 Itinerant Laptop non-NNPI NIPR NTWK CAT6 RJ-45 Y Facilities P1 Itinerant Laptop U-NNPI NIPR NTWK CAT6 RJ-45 Y Facilities

- Power 120 VAC 20 Amp 2-gang NEMA 20 N Integrator

AV14 Wall mount 201/4W-334 - South Wall, Side Wall AV Connections

14.a. Itinerant Laptop U-NNPI Video CAT6 RJ-45 Y Integrator, HD TXC 4KZ 101 14.b. Itinerant Laptop non-NNPI Video CAT6 RJ-45 Y Integrator, HD TXC 4KZ 101 14.c. UC-SB1-CAM Room USB Webcam CAT6 RJ-45 Y Integrator, USB-EXT-3-LOCAL 14.d. Crestron TS-1070-GV-B-S to DMPS3 CAT6 RJ-45 Y Integrator

- Power 120 VAC 20 Amp 2-gang NEMA 20 N Integrator

Sheet1

File details come from the government source that posted it. Updated .