Doral_Police_HQ_Concept_SD_Architectural_Drawings_Renderings_.pdf
PDF 14 MB Posted
- Attached to
- SRF Water System Upgrades
- Solicitation number
- 2026-04
- Issued by
- Miami-Dade County, Florida
About this file
This is an architectural design document prepared by Stantec Architecture Inc. for the City of Doral Police Department Headquarters project located at 3719 NW 97th Avenue, Doral, Florida 33178. The conceptual and schematic design drawings depict a three-story police headquarters facility on a 10.78-acre property zoned as Industrial Commercial District (IC). The facility encompasses approximately 62,933 gross square feet across three levels, with ground level functions including patrol operations, general investigations, community outreach, training units, and secured evidence storage; level two housing executive and administrative offices, internal affairs, and the Chief's office; and level three dedicated to specialized operations, tactical response, training facilities, and evidence vaults. The site plan includes 200 total parking spaces (149 new spaces plus 56 secured spaces), with an alternative fueling station option displacing nine parking spaces. The document provides detailed floor plans, reflected ceiling plans, elevations, sections, and three-dimensional renderings showing material specifications including tilt-up concrete panels, metal panel cladding, curtain wall glazing, and stucco finishes in white and gray tones.
The drawings indicate specialized equipment and security features throughout the facility, including high-density mobile storage systems, electronic evidence lockers with refrigeration and ventilation capabilities, smart weapons storage lockers with digital access control, and biometric card readers in information technology areas. The facility accommodates various operational requirements such as a motorcycle garage, K-9 unit spaces, roll call room, real-time operations center, and multipurpose community room. Construction-related specifications note interior wall options including concrete, CMU, and frame partition construction, with ceiling treatments combining acoustic tile, gypsum wallboard, and exposed structural elements at heights ranging from 8 to 14 feet. The design reflects modern law enforcement facility standards with emphasis on security, evidence integrity, operational efficiency, and public interface spaces, though the document does not specify construction timelines, budget allocations, or contract award information.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
1/
/2
1:
:4
PM
1" = 300'-0"
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
COVER SHEET
G-000
219421076
3719 NW 97th AVE Doral, 33178
Approver
CITY OF DORAL
POLICE DEPARTMENT
HEADQUARTERS
November 20, 2025
GENERAL
No. Sheet Name
G-000 COVER SHEET
G-001 SITE SURVEY
ARCHITECTURE
No. Sheet Name
A-000-OPT1 SITE PLAN
A-000-OPT2 SITE PLAN - FUELING STATION
A-001 PARKING COUNT
A-002 AREA PLAN - GROUND LEVEL
A-003 AREA PLAN - LEVEL 2
A-004 AREA PLAN - LEVEL 3
A-111 OVERALL PLAN - GROUND LEVEL
A-112 OVERALL PLAN - LEVEL 2
A-113 OVERALL PLAN - LEVEL 3
A-114 OVERALL PLAN - ROOF PLAN
A-121 REFLECTED CEILING PLAN - GROUND LEVEL
A-122 REFLECTED CEILING PLAN - LEVEL 2
A-123 REFLECTED CEILING PLAN - LEVEL 3
A-141 FFE SCHEDULE
A-201 ENLARGED PLAN - GROUND FLOOR - NORTH
NW 41ST ST
N W
7T
H A
VE
NW 33 ST
LOCATION MAP
SITE
CONCEPT & SCHEMATIC DESIGN
ARCHITECTURE
No. Sheet Name
A-202 ENLARGED PLAN - GROUND FLOOR - SOUTH
A-203 ENLARGED PLAN - LEVEL 2 - NORTH
A-204 ENLARGED PLAN - LEVEL 2 - SOUTH
A-205 ENLARGED PLAN - LEVEL 3 - NORTH
A-206 ENLARGED PLAN - LEVEL 3 - SOUTH
A-211 ELEVATIONS
A-212 ELEVATIONS
A-311 SECTIONS
A-601 RENDERED ELEVATION
A-602 3D VIEWS
A-603 3D VIEWS
A-604 3D VIEWS
A-605 3D VIEWS
A-606 3D VIEWS
SITE DATA
PROPERTY ADDRESS:
3379 NW 97TH AVE. DORAL, FLORIDA 33178
ZONING DISTRICT:
7100 INDUSTRIAL COMMERCIAL DISTRICT (IC)
NET LOT AREA:
469,790 SF (10.78 ACRES) / PER SURVEY DATED 9/22/2017
Rev. 12-10-2025
2025.11.20
ONE-STORY
D
D
T
D
N W
7t h
AV
EN
U
E
NW. 38th STREET
AS-BUILT SURVEY
SHEET:
DRAWN BY: ELF.
CHECKED BY: M.C.
FIELD DATE: 8/20/2017
SCALE: 1" = 40'
JOB No.
DATE: 9/22/2017
Pr ep ar ed fo r:
C
IT
Y O
F D
O R
AL
N o.
D at e
Jo b
N o.
D es cr ip tio n
SITE
M.
P.G
. T
EC
HN
IC
AL
G
RO
UP
, C
OR
P
S.
W . 1 st
A
VE
N U
E, M
IA
M
I, FL
O R
ID
A
Ph
5)
-9
N o.
L B
- 6
-Legal Description was furnished by client.
-Examination of Abstract of Title will have to be made to determined recorded instruments, if any, affecting the property.
-Legal Description subject to any dedication, limitation, restrictions, reservation, or easements of record.
-Underground improvements and utilities, if any, not located.
-Fences ownership by visual means only.
-Legal ownership not determined.
-The closure of the Boundary Survey is above 1' = 10,000 sq.ft.
-Bearings, if any, shown hereon are based upon assumed value.
-Benchmark used: (Miami-Dade County)N-513-R, Elevation: 7.46' (NGVD 1929) -Flood Zone "X", Base Flood Elev.: N/A.
FEMA Community: 120041, Community Name: City of Doral Panel Number: 12086C0286-L, September 11, 2009
Surveyor's Notes:
I HEREBY CERTIFY: that the attached AS-BUILT SURVEY of the above described property is correct to the best of my knowledge and belief as recently surveyed under my direction, and meets the intent of the Minimum Technical Standards set forth by the Florida Board of Professional Land Surveyors and Mappers in Chapter 5J-17, Florida Administrative Code, pursuant to Section 472.027, Florida Statutes.
DateMichael Carozza Professional Surveyor and Mapper
State of Florida, No. 6965 Not valid without the signature and the original raised seal of a Florida Licensed Surveyor and Mapper.
LEGEND
LOCATION MAP
NOT TO SCALE
N W
. 9 7t h
AV
EN
U
E
NW. 33rd STREET
"DORAL POLICE SUBSTATION FACILITY"
SYMBOLS
S D
T
PARCEL "A"
A Parcel of land lying in the South 1/2 of the Northwest 1/4 of Section 28, Township 53, South, Range 40 East, City of Doral, Miami-Dade County Florida, being more particularly described as follows:
Commence at the Southwest corner of the Northwest 1/4 of said Section 28; thence North 01°18'59" West, along the West line of said Section 28 for 616.61 feet to the Westerly projection of the South line of the lands described in Lease Number 4276 of the Board of Trustees of the Internal Improvement Trust Fund of the State of Florida to the State of Florida Department of Management Services, State Technology Office, dated October 30, 2000, said point also being the POINT OF BEGINNIG of the parcel of land hereinafter described; thence continue North 01°18'59" West along the West line of said Section 28 for 466.69 feet to point on the Westerly projection of the North line of the lands described in said Lease Number 4276; thence North 89°54'24" East along the North line of the lands described in Lease No. 4276 of the Board of Trustees of the Internal Improvement Fund of the State of Florida to the State of Florida, Department of Management Services, State Technology Office, dated October 39, 2000, for 506.69 feet to the the Northeast Corner of the lands described in said Lease Number 4276; thence South 01°18'59" East along the East Line of the lands described in said Lease Number 4276 for 469.69 feet to the Southeast corner of the lands described in said Lease Number 4276, said point also being on the North Line of Tract "A" of "DADE MADISON I" according to the plat thereof, as recorded in Plat Book 153, at Page 47 of the Public Records of Miami-Dade County, Florida; thence South 89°54'24" West along the North line of said Tract "A" of said plat of "DADE MADISON I", for 506.69 feet to the Point of Beginning.
Less and except the Westerly 40.00 feet for the Zoned right of way of NW. 97th Avenue.
AND
PARCEL "B"
A Parcel of land lying in Section 28, Township 53, South, Range 40 East, Miami Dade County Florida, more particularly described as follows:
Commence at the Southwest corner of the Northwest 1/4 of said Section 28; thence along the West line of said Section 28, North 01°18'59" West, 616.61 feet to the Westerly projection of the South line of the lands described in Lease Number 4276 of the Board of Trustees of the Internal Improvement Trust Fund of the State of Florida to the State of Florida Department of Management Services, State Technology Office, dated October 30, 2000; thence continue North 01°18'59" West along the West line of said Section 28, 466.69 feet to the Westerly projection of the North line of the lands described in said Lease Number 4276 and call this the Point Of Beginning; thence continue North 01°18'59" West along the West line of said Section 28, 239.64 feet to the South line of the North 1/2 of the Northwest 1/4 of said Section 28; thence North 89°57'12" East along the South line of the North 1/2 of the Northwest 1/4 of said Section 28, 704.53 feet (706.50 feet, calculated) to the the Northwest corner of the lands described as Southcom Parcel 3 in Amendment Number 1 to Lease Number 4489 of the Board of Trustees of the Internal Improvement Trust Fund of the State of Florida to the State of Florida Department of Management Services dated January 8, 2007; thence South 01°29'09" East, (South 01°19'34"East, Calculated) along the West boundary of the lands described in said Amendment Number 1 to Lease Number 4489, 705.76 feet to the Northeast Corner of "DADE MADISON I", Tract "A" as recorded in Plat Book 153 at Page 47 of the Public Records of Miami Dade County, Florida; thence South 89°54'24" West along the North line of "DADE MADISON I", Tract "A", a distance of 199.91 feet to the Southeast corner of the lands described im Lease Number 4276 of the Board of Trustees of the Internal Improvement Trust Fund of the State of Florida to the State of Florida Department of Management Services, State Technology Office, dated October 30, 2000; thence North 01°18'59" West along the East line of the lands described in said Lease Number 4276, 468.89 to the Northeast corner of the lands described in said Lease Number 4276; thence South 89°54'24" West along the North line of the lands described in said Lease Number 4276, 506.69 feet to the Point of Beginning;
Less and except the Westerly 40.00 feet for the Zoned right of way of 97th Avenue.
Containing 469,790 square feet, 10.78 acres, more or less, by calculations. (Subject parcel and remainder parcel)
Property Address: NW. 97th Avenue and approximately NW. 35th Street, Doral, Florida, 33172.
Folio No.: 35-3028-000-0010 (Parent Tract)
Legal Description:
PO
LI
C E
SU
BS
TA
TI
O N
F
AC
IL
IT
Y
N
W
7T H
A
VE
D O
R
AL
, F L
UP
PERIMETER
SECURITY CHAIN
LINK FENCE 8'
EXISTING RETENTION AREA
EXISTING
TRAINING
FACILITY
G
EN
ER
AT
O R
ELEC.
ROOM
EXISTING ELEC.
TRANSFORMER
SLIDING GATE
SLIDING GATE
TANDEM
PARKING
TRASH
ADJACENT BUILDING
ADJACENT BUILDING
N W th A
VE
N
U E
EXISTING 6'
CHAIN LINK
FENCE
EXISTING 6'
METAL FENCE
FIRE
PUMP
WATER
PUMP
PROPERTY LINE
PL
PL
PL
PL
8' TALL PRECAST
CONCRETE PANELS
PROPOSED
SECURED
PARKING
PROPOSED
WETLANDS
PROPOSED
WETLANDS
PROPOSED LAKE
PERIMETER
SECURITY WALL
PARKING LOT
LIGHTS
EXISTING ACCESS ROAD
EXISTING CONCRETE SIDEWALK
PROPOSED PARKING
PROPOSED 3-STORY POLICE
HEADQUATER BUILDING
PROPOSED PARKING LOT
EXISTING ACCESS ROAD
EXISTING
CONCRETE
SIDEWALK
EXISTING TRAINING
FACILITY SIDEWALK
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:4
PM
1" = 30'-0"
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
SITE PLAN
A-000-OPT1
219421076
3719 NW 97th AVE Doral, 33178
Approver
1" = 30'-0"
1 SITE PLAN
PERIMETER
SECURITY CHAIN
LINK FENCE 8'
PROPOSED
SECURED
PARKING
PROPOSED
WETLANDS
EXISTING
TRAINING
FACILITY
G
EN
ER
AT
O R
ELEC.
ROOM
EXISTING ELEC.
TRANSFORMER
SLIDING GATE
SLIDING GATE
TRASH
ADJACENT BUILDING
ADJACENT BUILDING
N W th A
VE
N
U E
FIRE
PUMP
WATER
PUMP
PROPERTY LINE
PL
PL
PL
PL
PROPOSED
WETLANDS
PROPOSED LAKE
FUEL DISPENSERS
CANOPY
5K FUEL TANK
ABOVE GROUND
8' TALL PRECAST
CONCRETE PANELS
12' - 0"
5' - 0"
15' - 4"
PARKING LOT
LIGHTS
EXISTING ACCESS ROAD
EXISTING CONCRETE SIDEWALK
EXISTING RETENTION AREA
TANDEM
PARKING
EXISTING 6'
CHAIN LINK
FENCE
EXISTING 6'
METAL FENCE
EXISTING TRAINING
FACILITY SIDEWALK
PROPOSED PARKING LOT
EXISTING ACCESS ROAD
EXISTING
CONCRETE
SIDEWALK
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:4
PM
1" = 30'-0"
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
SITE PLAN - FUELING STATION
A-000-OPT2
219421076
3719 NW 97th AVE Doral, 33178
Approver
1" = 30'-0"
1 SITE PLAN
NOTE:
9 PARKING SPOTS REPLACED BY
FUEL DISPENSER STATION
200 PARKING SPOTS TOTAL
2025.12.10
8 P
AR
KIN
G
SP
AC
ES
10 PARKING SPACES
10 PARKING
SPACES
10 PARKING SPACES
8 PARKING SPACES
3 ADA PARKING
SPACES
4 PARKING
SPACES
10 PARKING SPACES
10 TANDEM SPACES
6 PARKING SPACES
6 TANDEM SPACES
6 PARKING SPACES
56 SECURED
PARKING
(16 TANDEM)
2 ADA
PARKING
SPACES
5 P
AR
KIN
G
SP
AC
ES
6 P
AR
KIN
G
SP
AC
ES
6 P
AR
KIN
G
SP
AC
ES
3 P
AR
KIN
G
SP
AC
ES 10
P
AR
KIN
G
SP
AC
ES
209 REGULAR PARKING SPACES
& 9 ADA PARKING SPACES
2 P
AR
ES
2 P
AR
ES
PA
RK
IN
G
SP
AC
ES
PA
RK
ING SP
ACES
8 P
ARK
ING SP
ACES6 P
ARK
ING SP
ACES
PA
RK
IN
G
SP
AC
ES
P
AR
KIN
G
SP
AC
ES
PARKING SP
ACES
4 ADA PARKING
SPACES
9 PARKING
SPACES
10 PARKING
SPACES
6 PARKING SPACES
4 PARKING SPACES
10 PARKING SP
ACES
149 NEW PARKING
SPOTS
SLIDING GATE
SLIDING GATE
G
EN
ER
AT
O R
TRASH
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:3
PM
3/64" = 1'-0"
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
PARKING COUNT
A-001
219421076
3719 NW 97th AVE Doral, 33178
Approver
3/64" = 1'-0"
1 PARKING COUNT
LEGEND
ARMORY
BATHROOMS
BODY WORN CAMERA
BREAKROOM
CORRIDOR
CSI
FIELD & TRAINING
UNIT
FRONT DESK
K-9
MEP ROOMS
MULTIPURPOSE ROOM
OPERATIONS
PROPERTY AND
EVIDENCE
INTERVIEW ROOM
RECEPTION
WAITING
IT ROOM
TACTICAL RESPONSE UNIT
MOTORCYCLE GARAGE
CRIME SCENE
INVESTIGATION
SUPERVISOR
HIGH BULK STORAGE
STORAGE
LIEUTENANT
LIEUTENANT
CAPTAIN
SPECIAL OPERATIONS
MULTIPRPOSE ROOM
(COMMUNITY ROOM)
BIOHAZARD VAULT
JEWERLY VAULT
NARC VAULT
WEAPONS VAULT
PROPERTY EVIDENCE
FIRE PUMP
CAPTAIN
LIEUTENANT
SERGEANT
ADMIN
PROCESSING AND
OVERSIZED STORAGE
JANITOR'S
STORAGE
RECEPTION SERVICE
TRAINING UNIT
LIEUTENANT STORAGE
DOMESTIC WATER PUMP
ELECTRICAL ROOM
ELEC.ROOM
STORAGE
ARMORY
K-9
STORAGE
ROLL CALL ROOM
OFFICE
BREAKROOM
PUBLIC RECORDS
PACKAGE DELIVERY
CAMERA ROOM
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:5
PM
1" = 10'-0"
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
AREA PLAN - GROUND LEVEL
A-002
219421076
3719 NW 97th AVE Doral, 33178
Approver
842 SF
231 SF
2,222 SF
1,622 SF
1,513 SF
1,063 SF
1,873 SF
2,970 SF
2,463 SF
5,364 SF
TOTAL GROSS = 24,982 SF
2,928 SF
892 SF
999 SF
DN
LEGEND
BATHROOMS
BREAKROOM
BUDGET
COMMUNITY
OUTREACH
CORRIDOR
FIELD & TRAINING
UNIT
GENERAL
INVESTIGATION
MEP ROOMS
PATROL
REAL TIME
OPERATIONS
PATROL
CONFERENCE ROOM
OFFICE
OFFICE
OFFICE
IT ROOM
BUDGET OFFICE
PAYROLL OFFICE STORAGE COPY ROOM
K-9 THERAPY AREA
PAYROLL OFFICE
GENERAL INVESTIGATION
CAPTAIN
CONFERENCE ROOM
CRIME ANALYST
CRIME ANALYST
CRIME ANALYST
CRIME ANALYST
CRIME ANALYST
COPY ROOM
INTERVIEW
LIEUTENANT
KID'S INTERVIEW
VICTIMS INTERVIEW
INTERVIEW
COMMUNITY OUTREACH
CAPTAIN
COPY ROOM
LIEUTENANT
LIEUTENANT
LIEUTENANT
LIEUTENANT
STORAGE JANITOR'S
REAL TIME
OPERATIONS
OFFICE
OFFICE
IT OFFICE
BREAKROOM
COMMUNICATIONS
ELEC.ROOM
OFFICESTORAGE
GYM/CROSSFIT AREA
BREAKROOM
STORAGE
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:5
PM
1" = 10'-0"
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
AREA PLAN - LEVEL 2
A-003
219421076
3719 NW 97th AVE Doral, 33178
Approver
817 SF
1,209 SF
3,419 SF
2,779 SF
5,769 SF
501 SF
3,705 SF
TOTAL GROSS = 23,960 SF
1,461 SF
3,216 SF
1,084 SF
LEGEND
BATHROOMS
BREAKROOM
COMMANDER'S OFFICE
CORRIDOR
INTERNAL AFFAIRS
MEP ROOMS
OFFICE OF THE CHIEF
LIEUTENANT
OFFICER
INTERNAL AFFAIRS
CONFERENCE ROOM
OFFICER
COPY ROOOM
STORAGE
EXECUTIVE STORAGE COPY ROOM
EXECUTIVE
BUDGET OFFICE
DEPUTY CHIEF
CHIEF OFFICE
IT/MDF ROOM
EXECUTIVE ASSISTANT
JANITOR'S
BREAKROOM
TERRACE
BREAKROOM
ELEC.ROOM
STORAGE
MAJOR
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE OFFICE OFFICE
CONFERENCE ROOM
EXECUTIVE COMMANDER
OFFICES
MAJOR OFFICE OFFICE OFFICE
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:5
PM
1" = 10'-0"
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
AREA PLAN - LEVEL 3
A-004
219421076
3719 NW 97th AVE Doral, 33178
Approver
557 SF
3,411 SF
1,873 SF
456 SF
TOTAL GROSS = 13,991 SF
2,296 SF
4,681 SF
717 SF
5'
- 8
5'
- 0
0'
- 8
120' - 0"
7' - 0" 20' - 3" 19' - 9" 20' - 0" 20' - 0" 20' - 0" 5' - 0" 8' - 0"
229 SF
IT ROOM
472 SF
CRIME SCENE
INVESTIGATION
938 SF
MOTORCYCLE GARAGE
160 SF
CAPTAIN
112 SF
LIEUTENANT
103 SF
LIEUTENANT
H
759 SF
ROLL CALL ROOM
100 SF
OFFICE
552 SF
TACTICAL RESPONSE UNIT
GFEDCBA
165 SF
RECEPTION SERVICE
869 SF
RECEPTION
WAITING
166 SF
INTERVIEW ROOM
64 SF
JANITOR'S
182 SF
SUPERVISOR
81 SF
STORAGE
608 SF
HIGH BULK STORAGE
1786 SF
MULTIPRPOSE
ROOM (COMMUNITY
ROOM)
99 SF
STORAGE
674 SF
SPECIAL OPERATIONS
87 SF
STORAGE
1207 SF
TRAINING UNIT
648 SF
ARMORY
1299 SF
PROPERTY EVIDENCE
142 SF
BIOHAZARD VAULT
130 SF
JEWERLY VAULT
127 SF
NARC VAULT
136 SF
WEAPONS VAULT
701 SF
PROCESSING AND
OVERSIZED STORAGE
586 SF
VEHICLE STORAGE BAY
819 SF
BREAKROOM
143 SF
CAPTAIN
178 SF
LIEUTENANT
128 SF
STORAGE
79 SF
ELEC.ROOM
184 SF
FIRE PUMP
150 SF
DOMESTIC WATER PUMP
250 SF
ELECTRICAL ROOM
104 SF
STORAGE
128 SF
LIEUTENANT
128 SF
SERGEANT
139 SF
ADMIN
411 SF
K-9
CR
CR
CR
CR
CR
CR
CR
CR
CR CR
CR
CR
CR
CR
CR
CRCR
CR
CR
CR
CR
CR
CR
CR
CR
CR CRCR
CR
CR
I
STAIR 1
STAIR 2
STAIR 3
BR
564 SF
PUBLIC RECORDS
CR
CR
CR
CR
CR
CR
CR
105 SF
CAMERA ROOM
93 SF
PACKAGE DELIVERY
CR
CR
LEGEND - WALL TYPE
INTERIOR - CONCRETE
(OPTION A) - INTERIOR CONCRETE
(OPTION B) - CMU ALTERNATE. WALLS TO UNDERSIDE
OF STRUCTURE
INTERIOR - FRAME PARTITION
EXTERIOR - TILT-UP CONCRETE 12"
CR
LEGEND - SYMBOLS
CARD READER
BIOMETRICS READER (ONLY IT ROOMS)
CR
BR
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:5
PM
1" = 10'-0"
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
OVERALL PLAN - GROUND LEVEL
A-111
219421076
3719 NW 97th AVE Doral, 33178
Approver
7' - 0" 20' - 3" 19' - 9" 20' - 0" 20' - 0" 20' - 0"
7' - 0" 20' - 3" 19' - 9" 20' - 0" 20' - 0" 20' - 0" 5' - 0"
112' - 0"
308 SF
CAPTAIN
200 SF
LIEUTENANT
104 SF
COPY ROOM
117 SF
CRIME ANALYST
118 SF
CRIME ANALYST
118 SF
CRIME ANALYST
117 SF
CRIME ANALYST
116 SF
CRIME ANALYST
2449 SF
GENERAL INVESTIGATION
2057 SF
PATROL
128 SF
PAYROLL OFFICE
119 SF
STORAGE
109 SF
COPY ROOM
233 SF
PAYROLL OFFICE
874 SF
COMMUNITY OUTREACH
H
5'
- 8
5'
- 0
0'
- 8
GFEDCBA
140 SF
INTERVIEW
363 SF
CONFERENCE ROOM
245 SF
KID'S INTERVIEW
270 SF
STORAGE
114 SF
OFFICE
186 SF
CONFERENCE ROOM
228 SF
IT ROOM
763 SF
BUDGET OFFICE
309 SF
K-9 THERAPY AREA
Not Enclosed
GYM/CROSSFIT AREA
128 SF
OFFICE
124 SF
OFFICE
262 SF
VICTIMS INTERVIEW
148 SF
INTERVIEW
223 SF
OFFICE
130 SF
CAPTAIN
88 SF
COPY ROOM
150 SF
LIEUTENANT
142 SF
OFFICE
142 SF
OFFICE
141 SF
IT OFFICE
1482 SF
REAL TIME
OPERATIONS
253 SF
BREAKROOM
966 SF
COMMUNICATIONS
79 SF
ELEC.ROOM
136 SF
LIEUTENANT
132 SF
LIEUTENANT
111 SF
LIEUTENANT
86 SF
STORAGE
54 SF
JANITOR'S
102 SF
STORAGE
124 SF
STORAGE
CR
CR
CR
CR
CR
CR
CR
CR
CR
CR
CR
CR
CR
CR
I
CR
CR
CR
CR
CR
BR
LEGEND - WALL TYPE
INTERIOR - CONCRETE (OPTION A)
INTERIOR - CMU (OPTION B)
INTERIOR - FRAME PARTITION
EXTERIOR - TILT-UP CONCRETE 12"
LEGEND - SYMBOLS
CARD READER
BIOMETRICS READER (ONLY IT ROOMS)
CR
BR
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:0
PM
1" = 10'-0"
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
OVERALL PLAN - LEVEL 2
A-112
219421076
3719 NW 97th AVE Doral, 33178
HGFEDCBA
304 SF
LIEUTENANT
279 SF
CONFERENCE ROOM
180 SF
OFFICER
118 SF
OFFICE
119 SF
OFFICE
118 SF
OFFICE
103 SF
OFFICE
107 SF
OFFICE
107 SF
OFFICE
126 SF
OFFICE
124 SF
OFFICE
123 SF
OFFICE
372 SF
CONFERENCE ROOM
164 SF
STORAGE
217 SF
MAJOR
111 SF
OFFICE
1027 SF
EXECUTIVE COMMANDER
OFFICES
644 SF
BREAKROOM
308 SF
IT/MDF ROOM
320 SF
DEPUTY CHIEF
143 SF
BUDGET OFFICE
197 SF
EXECUTIVE
261 SF
OFFICER
59 SF
COPY ROOOM
196 SF
STORAGE
119 SF
COPY ROOM
117 SF
STORAGE
304 SF
BREAKROOM
411 SF
INTERNAL AFFAIRS
188 SF
MAJOR
198 SF
EXECUTIVE ASSISTANT
79 SF
ELEC.ROOM
637 SF
CHIEF OFFICE
174 SF
EXECUTIVE
372 SF
TERRACE
54 SF
JANITOR'S
CR
CR
CR
CR
CR
CR
CR
CR
CR
CR
I
STAIR 1
STAIR 2
CR
CR
CR
CR
CR
CR
CR
CR
628 SF
OFFICE OF THE CHIEF
747 SF
CONFERENCE ROOM
BR
67 SF
CLOSET
LEGEND - WALL TYPE
INTERIOR - CONCRETE (OPTION A)
INTERIOR - CMU (OPTION B)
INTERIOR - FRAME PARTITION
EXTERIOR - TILT-UP CONCRETE 12"
LEGEND - SYMBOLS
CARD READER
BIOMETRICS READER (ONLY IT ROOMS)
CR
BR
ROOF
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:0
PM
1" = 10'-0"
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
OVERALL PLAN - LEVEL 3
A-113
219421076
3719 NW 97th AVE Doral, 33178
5'
- 8
5'
- 0
7' - 0" 20' - 3" 19' - 9" 20' - 0" 20' - 0" 20' - 0" 5' - 0"
HGFEDCBA
44' - 0"
30' - 0"
UPPER ROOF
LOWER ROOF
TERRACE
30' - 0"
RTU
RTU RTU
RTU
RTU
I
ROOF BELOW
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:0
PM
1" = 10'-0"
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
OVERALL PLAN - ROOF PLAN
A-114
219421076
3719 NW 97th AVE Doral, 33178
HGFEDCBA
120' - 0"
7' - 0" 20' - 3" 19' - 9" 20' - 0" 20' - 0" 20' - 0" 5' - 0"
0'
- 8
5'
- 8
5'
- 0
I
8' - 0"
EXP
14' - 0"
CONC
9' - 0"
CONC
9' - 0"
EXP
14' - 0"
GWB
8' - 0"
CONC
9' - 0"
CONC
9' - 0"
EXP
14' - 0"
EXP
14' - 0"
EXP
14' - 0"
EXP
14' - 0"
EXP
14' - 0"
EXP
14' - 0"
EXP
14' - 0"
GWB
8' - 0"
GWB
8' - 0"
GWB
8' - 0"
GWB
8' - 0"
GWB
8' - 0"
GWB
8' - 0"
ACT
13' - 0"
ACT
13' - 0"
GWB
8' - 0"
GWB
8' - 0"
EXP
14' - 0"
ACT
9' - 0"ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
EXP
14' - 0"
EXP
14' - 0"
ACT
9' - 0"
ACT
9' - 0"
CONC
9' - 0"
CONC
9' - 0"
CONC
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
STAIR 1
STAIR 2
STAIR 3
GWB
8' - 0"
ACT
9' - 0"
GWB
10' - 0"
GWB
10' - 0"
GWB
10' - 0"
PROPERTY EVIDENCE
PROCESSING AND
OVERSIZED STORAGE
VEHICLE STORAGE BAY
HIGH BULK STORAGE
BIOHAZARD VAULT
JEWERLY VAULT
NARC VAULT
WEAPONS VAULT
FIRE PUMP
SERGEANT
CAPTAIN
LIEUTENANT
ADMIN
MEN'S RESTOOM
WOMEN'S RESTROOM
BREAKROOM
DOMESTIC WATER PUMP
STORAGE
PUBLIC RECORDS
RECEPTION SERVICE
INTERVIEW ROOM
JANITOR'S
RECEPTION
WAITING
IT ROOM
TRAINING UNIT
LIEUTENANT STORAGE
SUPERVISOR
CRIME SCENE
INVESTIGATION
STORAGE
LIEUTENANT
LIEUTENANT
CAPTAIN
SPECIAL OPERATIONS
MOTORCYCLE GARAGE
ROLL CALL ROOM
K-9
TACTICAL RESPONSE UNIT
STORAGE
OFFICE CAMERA ROOM
ARMORY
STORAGE
ELEC.ROOM
ELECTRICAL ROOM
MULTIPRPOSE ROOM
(COMMUNITY ROOM)
ACT
9' - 0"
GWB
8' - 0"
LEGEND - RCP
ACT - ACOUSTIC TILE CEILING
GWB - GYPSUM WALLBOARD CEILING
EXP - EXPOSED
NOTE: RCP PROVIDED FOR CEILING
HEIGHTS AND MATERIAL REFERECE.
LITGHTING DESIGN TBD.
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:0
PM
1" = 10'-0"
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
REFLECTED CEILING PLAN - GROUND
LEVEL
A-121
219421076
3719 NW 97th AVE Doral, 33178
Approver
1" = 10'-0"
1 GROUND LEVEL - REFLECTED CEILING PLAN
HGFEDCBA I
EXP
12' - 0"
GWB
8' - 0"
GWB
8' - 0"
GWB
8' - 0"
GWB
8' - 0"
STAIR 1
STAIR 2
STAIR 3
ACT
9' - 0"
GWB
8' - 0"
ACT
10' - 0"
ACT
8' - 0"
EXP
12' - 0" EXP
12' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0" ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
CONFERENCE ROOM
OFFICE CAPTAIN
OFFICE OFFICE
COPY ROOM
PATROL
LIEUTENANT
LIEUTENANT
LIEUTENANT
LIEUTENANT
STORAGE
OFFICE
OFFICE
IT OFFICE
IT ROOM
REAL TIME
OPERATIONS
BREAKROOM
REAL TIME
OPERATIONS
COMMUNICATIONS
PAYROLL OFFICE STORAGE COPY ROOM
BUDGET OFFICE
K-9 THERAPY AREA
COMMUNITY OUTREACH
PAYROLL OFFICE
GENERAL INVESTIGATION
GENERAL INVESTIGATION
CAPTAIN
CONFERENCE ROOM
CRIME ANALYST
CRIME ANALYST
CRIME ANALYST
CRIME ANALYST
CRIME ANALYST
COPY ROOM
STORAGE
KID'S INTERVIEW
VICTIMS INTERVIEW
BREAKROOM
WOMEN'S LOCKER ROOM
MEN'S LOCKER ROOM
GYM/CROSSFIT AREA
STORAGE OFFICE
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
GWB
9' - 0"
ACT
9' - 0"
GWB
9' - 0"
LEGEND - RCP
ACT - ACOUSTIC TILE CEILING
GWB - GYPSUM WALLBOARD CEILING
EXP - EXPOSED
NOTE: RCP PROVIDED FOR CEILING
HEIGHTS AND MATERIAL REFERECE.
LITGHTING DESIGN TBD.
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:0
PM
1" = 10'-0"
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
REFLECTED CEILING PLAN - LEVEL 2
A-122
219421076
3719 NW 97th AVE Doral, 33178
Approver
1" = 10'-0"
1 LEVEL 2 - REFLECTED CEILING PLAN
HGFEDCBA I
EXP
GWB
8' - 0"
GWB
8' - 0"
GWB
8' - 0"
GWB
8' - 0"
ACT
10' - 0"
7' - 0" 20' - 3" 19' - 9" 20' - 0" 20' - 0" 20' - 0" 5' - 0" 8' - 0"
120' - 0"
5'
- 8
5'
- 8
STAIR 1
STAIR 2
GWB
8' - 0"
ACT
9' - 0"ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0" ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
INTERNAL AFFAIRS
LIEUTENANT
CONFERENCE ROOM
OFFICER
EXECUTIVE
STORAGE COPY ROOM
STORAGE
EXECUTIVE
BUDGET OFFICE
BREAKROOM
DEPUTY CHIEF
CONFERENCE ROOM
CHIEF OFFICE
IT/MDF ROOM
CLOSET
EXECUTIVE ASSISTANT
OFFICE OF THE CHIEF
MAJOR
OFFICE OFFICE OFFICE
EXECUTIVE COMMANDER
OFFICES
CONFERENCE ROOM
OFFICE OFFICE OFFICE
OFFICE
OFFICE
OFFICE
MAJOR
STORAGE
MEN'S RESTROOM
WOMEN'S RESTROOM
GWB
10' - 0"
ACT
10' - 0"
GWB
9' - 0"
ACT
9' - 0"
LEGEND - RCP
ACT - ACOUSTIC TILE CEILING
GWB - GYPSUM WALLBOARD CEILING
EXP - EXPOSED
NOTE: RCP PROVIDED FOR CEILING
HEIGHTS AND MATERIAL REFERECE.
LITGHTING DESIGN TBD.
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:0
PM
1" = 10'-0"
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
REFLECTED CEILING PLAN - LEVEL 3
A-123
219421076
3719 NW 97th AVE Doral, 33178
Approver
1" = 10'-0"
1 LEVEL 3 - REFLECTED CEILING PLAN
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:0
PM
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
FFE SCHEDULE
A-141
219421076
3719 NW 97th AVE Doral, 33178
Approver
EQUIPMENT SCHEDULE
Mark ROOM DESCRIPTION MANUFACTURER COUNT MATERIAL CONSTRUCTION
POWER
OPERATED COMMENTS
EQ-01 Property & Evidence Mobile High Density Wide Span Shelving Southwest Solutions Group_SPA 1 SSG_Metal_Steel_Cast Mobile Storage Yes 16"x293"x87" - 6 shelving units shown in plan EQ-02 Property & Evidence Electronic Control Evidence Lockers Southwest Solutions Group_SPA 4 SSG_Metal_Steel_PBR Pass Through Yes 24"x36"x82" EQ-03 Weapons Vault Smart Weapons Lockers Southwest Solutions Group_DAS 10 SSG_Metal_Steel_PBR NON - Pass Through Yes 15"x22"x72" EQ-03 ARMORY Smart Weapons Lockers Southwest Solutions Group_DAS 11 SSG_Metal_Steel_PBR NON - Pass Through Yes 15"x22"x72" EQ-04 Weapons Vault Universal Weapon Rack Southwest Solutions Group_SPA 3 NON - Pass Through No 16"x42"x61 3/8" EQ-04 ARMORY Universal Weapon Rack Southwest Solutions Group_SPA 6 NON - Pass Through No 16"x42"x61 3/8" EQ-05 Crime Scene Investigation Electronic Control Evidence Lockers Southwest Solutions Group_SPA 9 SSG_Metal_Steel_PBR NON - Pass Through Yes 24"x36"x82" EQ-05 Jewelry Vault Electronic Control Evidence Lockers Southwest Solutions Group_SPA 8 SSG_Metal_Steel_PBR Refrigerated Locker Yes 17 1/4"x36"x82" EQ-06 Property & Evidence Electronic Control Evidence Lockers Southwest Solutions Group_SPA 1 SSG_Metal_Steel_PBR Refrigerated Locker Yes 24"x36"x82" EQ-06 Biohazard Vault Electronic Control Evidence Lockers Southwest Solutions Group_SPA 8 SSG_Metal_Steel_PBR Refrigerated Locker Yes 17 1/4"x36"x82" EQ-07 High Bulk Storage Spacesaver’s ActivRAC 3M High Density
Mobile Storage System puts your pallet racking on wheels and rail to maximize storage efficiency, allowing you to recover valuable floor space or double your storage capacity in the same space. ActivRAC’s durable, steel carriages are built in the USA and pair seamlessly with most pallet racking, mobilizing up to 3,000 pounds per carriage section.
Spacesaver Corporation 1 Mobile Storage Yes 145"x308"x144" - 5 Carriages
EQ-07 Processing & Oversized Storage Spacesaver’s ActivRAC 3M High Density Mobile Storage System puts your pallet racking on wheels and rail to maximize storage efficiency, allowing you to recover valuable floor space or double your storage capacity in the same space. ActivRAC’s durable, steel carriages are built in the USA and pair seamlessly with most pallet racking, mobilizing up to 3,000 pounds per carriage section.
Spacesaver Corporation 1 Mobile Storage Yes 145"x308"x144" - 5 Carriages
EQ-08 Narcotics Vault Electronic Control Evidence Lockers Southwest Solutions Group_SPA 8 SSG_Metal_Steel_PBR Ventilated (drying) Locker No 17 1/4"x36"x82" EQ-09 WOMEN'S LOCKER ROOM Southwest Solutions Group_HAM 10 SSG_Wood_Laminate_
Frosty_White Employee Locker No 18"x18"x76" - 2 Tier lockers (20 total)
EQ-09 MEN'S LOCKER ROOM Southwest Solutions Group_HAM 12 SSG_Wood_Laminate_ Frosty_White
Employee Locker No 18"x18"x76" - 2 Tier lockers (20 total)
SPECIALTY FURNITURE
1. EQ-01 - HIGH-DENSITY MOBILE STORAGE. 2. EQ-02 - EVIDENCE LOCKER - PASS-THROUGH
3. EQ-05 - EVIDENCE LOCKER
4. EQ-03 - GUN STORAGE - SMART LOCKERS WITH DIGITAL ACCESS CONTROL 5. EQ-04 - GUN STORAGE - ALL-STEEL CONSTRUCTION WITH REINFORCED DOORS
6. EQ-06 - EVIDENCE LOCKER - REFRIGERATED 7. EQ-07 - MOBILE STORAGE - ACTIVRAC HIGH DENSITY MOBILE STORAGE SYSTEM FOR PALLETS
6. EQ-08 - EVIDENCE LOCKER - VENTILATED 7. EQ-09 - EMPLOYEE (PERSONAL) LOCKER - 2 TIER
5'
- 8
7' - 0" 20' - 3" 19' - 9" 20' - 0" 20' - 0" 20' - 0" 5' - 0"
H
5'
- 1
0"
GFEDCBA
165 SF
RECEPTION SERVICE
531 166 SF
INTERVIEW ROOM
64 SF
JANITOR'S
608 SF
HIGH BULK
STORAGE
1786 SF
MULTIPRPOSE
ROOM (COMMUNITY
ROOM)
99 SF
STORAGE
648 SF
ARMORY
1"
5'
- 0
15' - 7"
7'
- 7
32' - 2"
11' - 11"
9'
- 1
0"
6'
- 1
1"
12' - 10" 9' - 2" 15' - 0"
7'
- 9
8' - 5"4' - 3"17' - 0"9' - 2"
5'
- 1
1"
4' - 8"7' - 2"
9'
- 0
8' - 5"7' - 0"
0"
29' - 4"6' - 9"
11' - 7"20' - 5"
14' - 3"6' - 0"13' - 11"
27' - 6"4' - 7"
9' - 1"
10' - 0" 17' - 11"
7'
- 1
1"
8'
- 8
8'
- 8
112' - 0"
198 SF
MEN'S RESTOOM
207 SF
WOMEN'S
RESTROOM
250 SF
ELECTRICAL ROOM
150 SF
DOMESTIC WATER
PUMP
819 SF
BREAKROOM
869 SF
RECEPTION
WAITING
143 SF
CAPTAIN
128 SF
LIEUTENANT
139 SF
ADMIN
128 SF
SERGEANT
701 SF
PROCESSING AND
OVERSIZED
STORAGE
586 SF
VEHICLE STORAGE
BAY
1299 SF
PROPERTY
EVIDENCE
184 SF
FIRE PUMP
142 SF
BIOHAZARD VAULT
130 SF
JEWERLY VAULT
127 SF
NARC VAULT
136 SF
WEAPONS VAULT
104 SF
STORAGE
I
42' - 7"5' - 0"
3'
- 1
0"
37' - 1"
7'
- 0
9' - 11" 12' - 0" 9' - 1"
8' - 2"
14' - 0"
564 SF
PUBLIC RECORDS
10' - 0" 16' - 8"
2'
- 1
1" 8'
- 1
6'
- 0
BULLETPROOF
SERVICE WINDOW
EQ-03
EQ-03
EQ-06
EQ-06
EQ-02
EQ-06
EQ-05
EQ-05
EQ-08
EQ-08
EQ-07
EQ-07
EQ-04
EQ-03
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:1
PM
As indicated
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
ENLARGED PLAN - GROUND FLOOR -
NORTH
A-201
219421076
3719 NW 97th AVE Doral, 33178
Approver
OFFICE FURNITURE:
1. OFFICE DESK 6'X6'
2. OFFICE DESK 8'X6'
KEY PLAN
NOTE:
REFER TO SHEET A-141 FOR
EQUIPMENT SCHEDULE
5'
- 0
112' - 0"
5'
- 0
H
19' - 0" 19' - 0"
9'
- 5
24' - 0"182 SF
SUPERVISOR
160 SF
CAPTAIN
938 SF
MOTORCYCLE
GARAGE
GFEDCBA
552 SF
TACTICAL
RESPONSE UNIT
472 SF
CRIME SCENE
INVESTIGATION
81 SF
STORAGE
112 SF
LIEUTENANT
103 SF
LIEUTENANT
674 SF
SPECIAL
OPERATIONS
759 SF
ROLL CALL ROOM
100 SF
OFFICE
87 SF
STORAGE
1207 SF
TRAINING UNIT
8' - 8"
8' - 2"10' - 1"
9' - 1" 30' - 8"
9' - 10"
6'
- 2
7' - 0" 20' - 3" 19' - 9" 20' - 0" 20' - 0" 20' - 0" 5' - 0"
178 SF
LIEUTENANT
128 SF
STORAGE
229 SF
IT ROOM
0"
11' - 10"
12' - 8" 9' - 4"
411 SF
K-9
7' - 11" 11' - 5"
16' - 7"39' - 4"
8'
- 3
8' - 7"
8'
- 3
10' - 4" 9' - 0"19' - 10"
6'
- 1
2'
- 0
20' - 4"9' - 5"
20' - 11"
10"
6'
- 0
2'
- 8
6'
- 0
10' - 1"
0"
16' - 0"
1'
- 1
0"
2' - 0"
8'
- 2
11' - 5"
93 SF
PACKAGE DELIVERY
9' - 1" 2' - 0" 9' - 1"
EQ-05
EQ-05
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:1
PM
As indicated
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
ENLARGED PLAN - GROUND FLOOR -
SOUTH
A-202
219421076
3719 NW 97th AVE Doral, 33178
Approver
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:1
PM
As indicated
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
ENLARGED PLAN - GROUND FLOOR -
SOUTH
A-202
219421076
3719 NW 97th AVE Doral, 33178
Approver
KEY PLAN
OFFICE FURNITURE:
1. OFFICE DESK 6'X6'
2. OFFICE DESK 8'X6'
NOTE:
REFER TO SHEET A-141 FOR
5'
- 8
2057 SF
PATROL
270 SF
STORAGE
114 SF
OFFICE
GFEDCBA
245 SF
KID'S INTERVIEW
270 SF
STORAGE
186 SF
CONFERENCE ROOM
12' - 8"
7' - 0" 20' - 3" 19' - 9" 20' - 0" 20' - 0" 20' - 0"
130 SF
CAPTAIN
128 SF
OFFICE
124 SF
OFFICE
88 SF
COPY ROOM
111 SF
LIEUTENANT
132 SF
LIEUTENANT
136 SF
LIEUTENANT
150 SF
LIEUTENANT
86 SF
STORAGE
54 SF
JANITOR'S
142 SF
OFFICE
142 SF
OFFICE
141 SF
IT OFFICE
228 SF
IT ROOM
2116 SF
GYM/CROSSFIT
AREA
223 SF
OFFICE
746 SF
BREAKROOM
79 SF
ELEC.ROOM
262 SF
VICTIMS INTERVIEW
411 SF
MEN'S LOCKER
ROOM
448 SF
WOMEN'S LOCKER
ROOM
9'
- 1
1"
9'
- 1
18' - 0" 14' - 5" 12' - 8"
6'
- 0
16' - 10"
1"
9'
- 6
17' - 4"
27' - 6"21' - 2"
17' - 11"
16' - 9"
5' - 1"
16' - 8"10' - 0"
6'
- 1
0"
7'
- 6
9'
- 9
12' - 11" 13' - 0"6' - 3"
5'
- 4
39' - 3"
19' - 2"11' - 4"
3'
- 2
33' - 0"
EQ-09
EQ-09
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:1
PM
As indicated
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
ENLARGED PLAN - LEVEL 2 - NORTH
A-203
219421076
3719 NW 97th AVE Doral, 33178
Approver
KEY PLAN
OFFICE FURNITURE:
1. OFFICE DESK 6'X6'
2. OFFICE DESK 8'X6'
NOTE:
REFER TO SHEET A-141 FOR
5'
- 0
H
9'
- 0
12' - 11" 11' - 10"
27' - 10"
8' - 10"
6'
- 0
10' - 10"
9'
- 5
308 SF
CAPTAIN
363 SF
CONFERENCE ROOM
2449 SF
GENERAL
INVESTIGATION
116 SF
CRIME ANALYST
104 SF
COPY ROOM
140 SF
INTERVIEW
874 SF
COMMUNITY
OUTREACH
309 SF
K-9 THERAPY AREA
233 SF
PAYROLL OFFICE
763 SF
BUDGET OFFICE
128 SF
PAYROLL OFFICE
119 SF
STORAGE
109 SF
COPY ROOM
GFEDCBA
200 SF
LIEUTENANT
117 SF
CRIME ANALYST
118 SF
CRIME ANALYST
118 SF
CRIME ANALYST
117 SF
CRIME ANALYST
9'
- 5
9'
- 3
" 15
0"
16' - 5"
112' - 0"
7' - 0" 20' - 3" 19' - 9" 20' - 0" 20' - 0" 20' - 0" 5' - 0"
7' - 8"
253 SF
BREAKROOM
36' - 11"
13' - 4"
9'
- 4
39' - 3"
16' - 5"
17' - 10"
0"
8' - 0"
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:1
PM
As indicated
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
ENLARGED PLAN - LEVEL 2 - SOUTH
A-204
219421076
3719 NW 97th AVE Doral, 33178
Approver
KEY PLAN
OFFICE FURNITURE:
1. OFFICE DESK 6'X6'
2. OFFICE DESK 8'X6'
NOTE:
REFER TO SHEET A-141 FOR
H
5'
- 8
GFEDCBA
7' - 0" 20' - 3" 19' - 9" 20' - 0" 20' - 0" 20' - 0"
9'
- 1
0"
9'
- 1
19' - 3" 19' - 2"
6'
- 1
1"
10' - 3"8' - 6"19' - 3"
21' - 2" 11' - 11" 11' - 11"
6'
- 0
143 SF
BUDGET OFFICE
174 SF
EXECUTIVE
197 SF
EXECUTIVE
117 SF
STORAGE
119 SF
COPY ROOM
304 SF
BREAKROOM
54 SF
JANITOR'S
261 SF
OFFICER
279 SF
CONFERENCE ROOM
59 SF
COPY ROOOM
196 SF
STORAGE
411 SF
INTERNAL AFFAIRS
304 SF
LIEUTENANT
180 SF
OFFICER
18' - 11" 9' - 3" 9' - 4"
9' - 3"
4'
- 3
9' - 2" 9' - 2"
6'
- 6
20' - 5"
14' - 4"6' - 1"
9'
- 9
9'
- 5
9'
- 5
9'
- 1
0"
15' - 10" 11' - 1"
164 SF
STORAGE
1027 SF
EXECUTIVE
COMMANDER
OFFICES
217 SF
MAJOR
111 SF
OFFICE
107 SF
OFFICE
107 SF
OFFICE
103 SF
OFFICE
123 SF
OFFICE
124 SF
OFFICE
126 SF
OFFICE
372 SF
CONFERENCE ROOM
188 SF
MAJOR
118 SF
OFFICE
119 SF
OFFICE
118 SF
OFFICE
79 SF
ELEC.ROOM
207 SF
MEN'S RESTROOM
207 SF
WOMEN'S
RESTROOM
7'
- 1
0"
7'
- 1 0"
1"
6'
- 0
15' - 7" 10' - 10"
12' - 0" 12' - 0"
6'
- 9
2'
- 3
10' - 0"
9' - 4"
6'
- 3
9' - 3"
8' - 8" 10' - 10"
7' - 8"20' - 0"
644 SF
BREAKROOM
628 SF
OFFICE OF THE
CHIEF
320 SF
DEPUTY CHIEF
747 SF
CONFERENCE ROOM
21' - 2"
2'
- 1
0"
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:1
PM
As indicated
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
ENLARGED PLAN - LEVEL 3 - NORTH
A-205
219421076
3719 NW 97th AVE Doral, 33178
Approver
KEY PLAN
OFFICE FURNITURE:
1. OFFICE DESK 6'X6'
2. OFFICE DESK 8'X6'
NOTE:
REFER TO SHEET A-141 FOR
H
7' - 0" 20' - 3" 19' - 9" 20' - 0" 20' - 0" 20' - 0" 5' - 0"
5'
- 0
ROOF TERRACE
G
FEDCBA
112' - 0"
7'
- 2
6' - 11"19' - 8"7' - 0"
6' - 11" 12' - 0"
6'
- 5
12' - 0"12' - 0"
11' - 11"14
6'
- 2
12' - 0"
8'
- 1
1"
7' - 6"9' - 4"9' - 10"
2'
- 1
1"
637 SF
CHIEF OFFICE
308 SF
IT/MDF ROOM
67 SF
CLOSET
747 SF
CONFERENCE ROOM
198 SF
EXECUTIVE
ASSISTANT
644 SF
BREAKROOM
79 SF
ELEC.ROOM
0"
ROOF
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:2
PM
As indicated
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
ENLARGED PLAN - LEVEL 3 - SOUTH
A-206
219421076
3719 NW 97th AVE Doral, 33178
Approver
KEY PLAN
OFFICE FURNITURE:
1. OFFICE DESK 6'X6'
2. OFFICE DESK 8'X6'
NOTE:
REFER TO SHEET A-141 FOR
L1 0' - 0"
L2 16' - 0"
L3 30' - 0"
L4 44' - 0"
43 5 6 7 8 9 10 11 12 1321 14
2A
1 52
1 4
L1 0' - 0"
L2 16' - 0"
L3 30' - 0"
L4 44' - 0"
4 35678910111213 2 114
P1
P3P2
P1 P1 P1
2A
1/8" = 1'-0"
1 EAST ELEVATION
1/8" = 1'-0"
2 WEST
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:2
PM
1/8" = 1'-0"
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
ELEVATIONS
A-211
219421076
3719 NW 97th AVE Doral, 33178
Approver
1. Metal Panel Cladding 2. Curtain Wall Glass
2A. Spandrel Glass
3. Tilt-up Concrete Panel - vertical pier
4. Signage 5. Metal Canopy 6. Vertical Metal Screen P1. Smooth Stucco (White) P2. Stucco with texture P3. Smooth Stucco (Gray)
7. Vertical Linear Lights
L2 16' - 0"
L3 30' - 0"
L4 44' - 0"
H G F E D C B A I
P2
P1
P3
2A
P1
2A
L1 0' - 0"
L2 16' - 0"
L3 30' - 0"
L4 44' - 0"
HGFEDCBA I6
2A
P1
P3
P2
P1
P1
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:3
PM
1/8" = 1'-0"
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
ELEVATIONS
A-212
219421076
3719 NW 97th AVE Doral, 33178
Approver
1/8" = 1'-0"
1 NORTH
1/8" = 1'-0"
2 SOUTH
1. Metal Panel Cladding 2. Curtain Wall Glass
2A. Spandrel Glass
3. Tilt-up Concrete Panel - vertical pier
4. Signage 5. Metal Canopy 6. Vertical Metal Screen P1. Smooth Stucco (White) P2. Stucco with texture P3. Smooth Stucco (Gray)
7. Vertical Linear Lights
L2 16' - 0"
L3 30' - 0"
L4 44' - 0"
H
A-311
A-311
GFEDCBA
229 SF
IT ROOM
1482 SF
REAL TIME
OPERATIONS
253 SF
BREAKROOM
637 SF
CHIEF OFFICE
308 SF
IT/MDF ROOM
262 SF
VICTIMS INTERVIEW
648 SF
ARMORY
228 SF
IT ROOM
I
869 SF
RECEPTION
WAITING
7'
- 6
L1 0' - 0"
L2 16' - 0"
L3 30' - 0"
L4 44' - 0"
4 35678910111213 2 114
A-311
A-311
1'
- 0
188 SF
MAJOR
1027 SF
EXECUTIVE COMMANDER
OFFICES
124 SF
OFFICE
372 SF
CONFERENCE ROOM
1027 SF
EXECUTIVE COMMANDER
OFFICES
207 SF
MEN'S RESTROOM
207 SF
WOMEN'S RESTROOM
270 SF
STORAGE
2116 SF
GYM/CROSSFIT AREA
411 SF
MEN'S LOCKER ROOM
411 SF
MEN'S LOCKER ROOM
448 SF
WOMEN'S LOCKER ROOM
207 SF
WOMEN'S RESTROOM
198 SF
MEN'S RESTOOM
139 SF
ADMIN
128 SF
LIEUTENANT
143 SF
CAPTAIN
2449 SF
GENERAL INVESTIGATION
552 SF
TACTICAL RESPONSE UNIT
411 SF
K-9
2449 SF
GENERAL INVESTIGATION
105 SF
CAMERA ROOM
674 SF
SPECIAL OPERATIONS
160 SF
CAPTAIN
148 SF
INTERVIEW
2449 SF
GENERAL INVESTIGATION
3'
- 0
7'
- 6
3'
- 0
1/8" = 1'-0"
2 LONGITUDINAL SECTION
1/8" = 1'-0"
1 CROSS SECTION
1 2 3 4 5
A
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:4
PM
1/8" = 1'-0"
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
SECTIONS
A-311
219421076
3719 NW 97th AVE Doral, 33178
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:4
PM
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
RENDERED ELEVATION
A-601
219421076
3719 NW 97th AVE Doral, 33178
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:4
PM
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
3D VIEWS
A-602
219421076
3719 NW 97th AVE Doral, 33178
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:4
PM
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
3D VIEWS
A-603
219421076
3719 NW 97th AVE Doral, 33178
B
C
D
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
Drawing No.
Project No.
Title
ORIGINAL SHEET - ARCH E1 (30"x42")
Issued
Revision
Revision
Scale
By Appd YYYY.MM.DD www.stantec.com
Stantec Architecture Inc - AA26000733
N
1/
/2
1:
:4
PM
A ut od es k D oc s:/
/2
_D or al
_P D
-H Q
/2
- A
SB
-D
O
RA
L- P
D .rv t
POLICE DEPARTMENT HEADQUARTERS
CITY OF DORAL
3D VIEWS
A-604
219421076
3719 NW 97th AVE Doral, 33178
B
C
D
The Contractor shall verify…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .