This document set contains technical specifications and layout diagrams for the OMD Security Enhancement Project, focusing on gate and access control equipment for a facility with a guard shack. The project involves installing a DoorKing Model 1601 barrier gate with a 10-foot arm, a reflective photo eye, and a PBS-3 three-button control station. The gate is designed for single lane vehicular control in high-traffic applications, with features including electronic limit settings, a 90-degree arm rotation in approximately 2.5 seconds, and a G90 galvanized steel housing. The equipment is rated for operation between 10°F to 140°F and is certified to CAN/CSA C22.2 NO. 247 and ANSI/UL-325 standards.

The technical specifications detail specific equipment requirements, including a 1/2 HP continuous duty AC motor, various voltage input options (115 VAC, 230 VAC, 460 VAC), and multiple arm type configurations. The project layout includes provisions for entry and exit lanes, with equipment positioned near a guard shack. Wiring specifications are provided, emphasizing proper grounding, wire sizing, and voltage drop considerations. Additional components include an optical monitoring device (OMD) with features like multiple monitoring methods, surge protection, and a wide operating temperature range. The documentation appears to be a comprehensive technical guide for implementing a security access control system with precise equipment and installation requirements.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FEATURES

• DESIGNED FOR SINGLE LANE (14 FT MAXIMUM)

VEHICULAR CONTROL IN HIGH TRAFFIC

APPLICATIONS

• ELECTRONIC LIMIT SETTINGS

• ARM ROTATES 90° IN APPROXIMATELY 2.5

SECONDS

• G90 GALVANIZED STEEL HOUSING

• FAIL-SECURE MECHANICAL RELEASE METHOD

• LEFT- OR RIGHT-HAND MOUNT

• 360° GEAR BOX ROTATION BEFORE THE MOTOR

CHANGES DIRECTION.

• ARM ROTATES 90° IN APPROXIMATELY 2.5

SECONDS

• G90 GALVANIZED STEEL HOUSING

• FAIL-SECURE MECHANICAL RELEASE METHOD

• LEFT- OR RIGHT- HAND MOUNT

• 360° GEAR BOX ROTATION BEFORE THE MOTOR

CHANGES DIRECTION.

• TEMPERATURE:10°F to 140°F (-12°C to 62°C)

CLASS

CERTIFIED TO

CAN/CSA C22.2 NO. 247

ANSI/UL-325

CONFORMS TO

VEHICULAR GATE OPERATOR

HP

53382

MODEL

SERIAL

VOLTS PHASE

AMPS 60 Hz

MAX GATE LOAD

DoorKing, Inc., Inglewood, CA

MOVING ARM

cause vehicle damage, can serious injury or death.

STAY

at all times.

CLEAR of arm

NO:

Bicycles Pedestrians

Motorcycles

WARNING

15”

41.1” 34.5”

14.5”

10.8”

Moving Gate Can Cause Serious Injury or Death KEEP CLEAR! Gate may move at any time without prior warning.

Do not let children operate the gate or play in the gate area.

This entrance is for vehicles only.

Pedestrians must use separate entrance.

Housing & Arm Cover 21”

CLASS OF OPERATION

ARM TYPE/MAX LENGTH

(ARMS ARE SOLD SEPARATELY)

MODEL

II, III, IV

Plastic / 12 ft (3.6 m) Wood / 14 ft (4.3 m)

Round Aluminum / 14 ft (4.3 m) Octagonal Aluminum / 14 ft (4.3 m)

MOTOR

INPUT

OPTIONS Convenience Open Package2

Heater and Fan Kits Folding Arm Kits5

Breakaway Arm Kit3

Octagonal Lighted Signal Arm 2-Piece Arm Kit4

115 VAC, 60 Hz, 5.4A 230 VAC, 60 Hz, 2.7A1

460 VAC, 60 Hz, 1.4A1

1/2 HP • Continuous Duty • AC Motor

OMD Security Enhancement Project:

1522924659.NFG

Highlight

1522924659.NFG

Highlight

Never run low voltage rated wire insulation in the same conduit as high voltage rated wire insulation.

Model Type

Voltage Required

Amps Required

Wire Size / Max Distance in Feet

115 5.7 170 275 460 690

12 AWG 10 AWG 8 AWG 6 AWG

1601 - 1/2 HP

115 9.7 100 162 270 4051602 - 1 HP

WIRING

Before attempting to connect any wiring to the operator, be sure that the circuit breaker in the electrical panel is in the OFF position. Permanent wiring must be installed to the operator as required by local electrical codes. It is recommended that a licensed electrical contractor perform this work.

Since building codes vary from city to city, we highly recommend that you check with your local building department prior to installing any permanent wiring to be sure that all wiring to the operator (both high and low voltage) complies with local code requirements.

THIS GATE OPERATOR MUST BE PROPERLY GROUNDED!!

2.1 High Voltage Wire Runs

The distance shown in the chart is measured in “Feet” from the operator to the power source. If power wiring is greater than the maximum distance shown, it is recommended that a service feeder be installed. When large gauge wire is used, a separate junction box must be installed for the operator connection. The wire table is based on stranded copper wire. Wire run calcula-tions are based on the NEC recommended maximum 3% voltage drop on the power line, plus an additional 10% reduction in distance to allow for other losses in the system.

This table illustrates the high voltage AC power wire size and distance limitations.

OMD Ft. Oregon Security Enhancement Project:

OMD Security Enhancement Project:

1522924659.NFG

Highlight

,-----,--.-----------------DIMS. Pel< SIT!: LAYOUT------------------t-----i

LOOP TO 61: CONTINUOUS Ll:NGTH OF Wll<e W/0 ANY 61<1:AKS 01< SPLICl:S

Ye' TO¼" SAW SLOT

!<!:MOVE: SHAl<P INSIDI: COl<Nl:l<S

QSeAL SeALANT TO 61: APPLll:D ON CLeAN SUl<FACI:

LOOP Wll<l:S [:2] WAAPS SHOWN Wll<l:S MUST LAY FLAT ON TOP OF

Pl<l:VIOUS TUl<N

H1/8"T01/4'

-LOOP Wll<I: SPl:C:

14GA 19STI< 600V XLP INSULATl:D OAANGe PVC-POLYVINYL CHLOl<IDI: TU61:.

-NUM61:I< OF WAAPS 6ASl:D ON LOOP size [3] WAAPS FOi< LOOP l='el<IMl:Tl:l<S 14'-:26' [:2] WAAPS FOi< LOOP Pl:l<IMl:Tel<S :27-80'

-see eLeCTl<ICAL LAYOUT FOi< SIT!:

SPl:CIFIC LOOP size AND LOCATION

Wll<e TO 61: TWISTl:D A MIN. OF 6 TUl<NS Pel< FOOT Fl<OM THI: !:ND OF THI: FeeDel< SLOT TO THI: l:XPANSION 60Al<D.

ALL SPLICl:S TO 61: SOLDl:1<1:D AND Pl<OTl:CTl:D WITH MOISTUl<e Pl<OOF SeAL.

OMD Security Enhancement Project:

FEATURES:

Operating Range:

5 (1.5 m) to 60 ft (18.3 m)

Power:

6-40 VDC, 12-24 VAC

Temperature Range:

-30° to 140°F (-34° to 60°C)

Current (NC and 10K Monitoring Methods) 50 mA DC (relay activated)

Current (Pulse Monitoring Methods) 15 mA DC

Resistive Termination 10K ohm across NO contact (switch selectable) Surge Protection

Thermal fuse, MOV Relay Output Operation

Light ON/Dark ON Response Time

250ms Environmental

NEMA 4X

Dimensions (L x W x H)

5.1” (130 mm) x 3.15” (80 mm) x 5.5” (140 mm) Ball Joint Mount Conduit Thread

½ Inch NPT

• NORMALLY CLOSED

• 10K RESISTIVE TERMINATION

• 2-WIRE PULSE (2 FREQUENCY)

• 2-WIRE PULSE (3 FREQUENCY)

• 4-WIRE PULSE (2 FREQUENCY)

• 4-WIRE PULSE (3 FREQUENCY)

UL325 MONITORING METHODS

OMD Security Enhancement Project

KNOCKOUT

HOLES

o NEMA 1 o SURFACE MOUNT o FULLY GUARDED o THREE BUTTON CONTROL

(OPEN-CLOSE-STOP) IN METAL

ENCLOSURE

o BUTTON: 5 amp @ 120VAC o 240VAC MAX GENERAL PURPOSE o OPEN: NORMALLY OPEN o CLOSE: NORMALLY OPEN o STOP: NORMALLY CLOSED o UL LISTED

230 Route 206, Suite 206

Flanders, NJ 07836

(800) 942-6682 * (973) 584-6682 Fax info@mmtcinc.com

5”

2-3/8”

PBS-3

CONTROL STATION

DIMENSIONS

WIRING

2-3/8”

2”

1-1/8”

7/8”

1-13/16”

OPEN

CLOSE

STOP

“OPEN”

COMMAND

“CLOSE”

COMMAND

CONTROL CIRCUIT

POWER

CONTROL CIRCUIT

COMMON

OMD Security Enhancement Project:

GUARD SHACK

1601 BARRIER GATE

WITH 10’ ARM

FOR REFERENCE ONLY

EQUIPMENT LOCATIONS

ARE TBD.

REFLECTIVE

PHOTO EYE

DOWN LOOP

(4’ x 8’)

(P U

B

LI

C S

ID

E

(SE

C U

R E

SID

E

ENTRY

EXIT

OMD Security Enhancement Project:

GUARD SHACK

2 - 3/4” TO 3-BUTTON STATION LOCATION & ELECT PANEL. (P

U

B

LI

C S

ID

E

(SE

C U

R E

SID

E

ENTRY

EXIT

OMD Security Enhancement Project:

Cover Page
Doorking 1601
Wiring
Sawcut Loop
IRB-RET2
Doorking Traffic Spikes
Doorking Speed Bump
Concrete
Doorking Warning Sign
3-Button Station
Equipment Layout
Electrical Layout

File details come from the government source that posted it. Updated .