amended_SOW_Part_2.pdf
PDF 2 MB Posted
- Attached to
- Award for ILAB Renovations Federal contract opportunity
- Solicitation number
- DOL-OPS-16-Q-00033
About this file
Amended SOW part 2 to remove the Refrigerator's and Microwave's
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Questions_and_Answers_for_Solicitation__DOL-OPS-16-Q-00033_Space_05.24.2016.pdf | ||
| Vendors_List.pdf | ||
| Amended_Solicitation_for_DOL-OPS-16-Q-00033_updated_05.24.2016.pdf | ||
| Past_Performance_Questionnaire-DOL-OPS-16-Q-00033.doc | DOC document | |
| SOW_Part_2.pdf | ||
| Davis_Bacon-Wage_Determination.docx | DOCX document | |
| SOW_Part_1--Door_Change.pdf | ||
| Solicitation__DOL-OPS-16-Q-00033.pdf | ||
| SOW_Part_3--Door_Change.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Appendix D
Demountable Partitions Specifications and Design
5th Floor ILAB Renovation Department of Labor FPB, Washington, DC MODULAR PARTITIONS
SECTION 102217- MODULAR PARTITIONS
Part 1 General
1.1 SUMMARY
1. Section includes:
a. Modular partitions framing;
b. Face tiles;
c. Glass and glazing;
d. Doors and door hardware;
e. Accessories.
f. Finishes.
1.2 REFERENCES
1. American Architectural Manufacturers Association (AAMA):
a. AAMA 61198 Voluntary Standards for Anodized Architectural Aluminum.
2. American Society of Civil Engineers (ASCE):
a. ASCE-7 Minimum Design Loads for Buildings and Other Structures.
3. ASTM International:
a. ASTM E72 Method for Conducting Strength Tests of Panels for Building Construction.
b. ASTM E84 Test Method for Surface Burning Characteristics of Building Materials.
c. ASTM E90 Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements.
d. ASTM E413 Classification for Rating Sound Insulation.
4. CAN/ULC-S102 Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies.
1.3 PERFORMANCE REQUIREMENTS
1. Structural Performance: Modular partitions shall be capable of withstanding the effects of gravity loads, dead loads, and the following loads and stresses within limits and under conditions indicated:
a. Transverse Load: Lateral deflection of the overall span when tested under a uniformly distributed load of 5 psf (0.24 kN/m2) in accordance with ASTM E72 where L = modular partition wall height:
i. Solid Walls: not more than L/120;
ii. Glass Walls: not more than L/175 or 3/4 inch (19 mm) which ever is more stringent.
b. Mechanical Strength: Capable of withstanding static loads in accordance with
ANSI/BIFMA X5.6.
c. Seismic Performance: Provide modular partitions capable of withstanding effects of seismic motions determined according to the currently adopted building codes.
2. Acoustical Performance: Where STC ratings are indicated, provide partitions with STC rating determined by testing an identical system to ASTM E90 and classified in accordance with ASTM E413.
a. Sound Transmission Coefficient (STC) range shall be determined in accordance with Sound Transmission Test by Two-Room Method and reported in accordance with ASTM E90 and ASTM E413 for frequency data. Tested assembly shall have been assembled in the same manner the modular partitions to be installed on the project.
b. Test results vary based on glass or solid wall configuration, and implementation of perimeter enhancements at base building connections.
i. Solid wall results range up to 50 STC performance.
ii. Glass wall performance is limited by the glass specified. Coordinate requriements with the modular partition manufacturer.
3. Fire Resistance:
a. Surface-Burning Characteristics: Tested in accordance with ASTM E84 by a qualified independent testing agency.
b. National Building Code of Canada, CAN/ULC-S102 Surface Burning Characteristics of Building Materials and Assemblies.
4. Sustainable Design Requirements: Submit project specific documentation to demonstrate the following:
a. MRc4.1 and 4.2 Recycled Content, calculated by weight:
i. MDF Standard Tiles: 100% pre-consumer recycled content.
ii. MDF No Added Formaldehyde Tiles: 90% pre-consumer recycled content.
iii. Solid Door Core Assemblies: 100% pre-consumer recycled content.
iv. Aluminum: Confirm with the manufacturer plant location.
b. MRc5 Regional Materials:
i. LEED NC: Minimum 20%.
ii. LEED-CI: Minimum 10%
c. MRc6 Rapidly Renewable Materials:
i. MDF and Wood Materials;
ii. Recycled Cotton Insulation;
iii. Decorative Components;
iv. Bio-Based Materials.
d. MRc7 Certified Wood:
i. FSC Certification Code: SCS-COC-000848.
ii. FSC License Number: FSC-C006900.
e. IEQc4 Low Emitting Materials:
i. IEQc4.1 Adhesives and Sealants and 4.2 Paints and Coatings:
1. Field Applied: Documented by project contractor.
2. Factory Applied: MSDS and VOC content available upon request.
ii. IEQc4.4 Composite Wood and Laminate Adhesives:
1. MDF Tiles: California Air Resources Board (CARB) 2 Certified.
f. IEQc8.1 Daylight and Views.
g. IEQc8.1 Daylight.
h. Innovation in Design (ID).
i. Pilot Credits:
i. Life Cycle Assessment (LCA);
ii. Environmental Product Declaration (EPD);
iii. Health Product Declaration (HPD);
iv. Life Cycle Impact Reduction.
v. Acoustic Measures.
vi. Lead Free Content including conduit: maximum 40ppm.
5. Coordination Requirements:
a. Comply with Division 01 project management and procedures.
b. Project Scheduling and Lead Times: Manufacturing production time of all standard products and finishes shall not exceed five weeks, inclusive of shipping within US and Canada, from receipt of complete order information (including shop drawing approval, deposit cost, and notice to proceed).
i. Maximum delivery time on solutions included on GSA contracts shall not exceed 45 days. Coordinate adjacent work, including other work by others to be installed within or next to Work of this section.
c. Schedule: Coordinate delivery with construction schedule to avoid storage or double handling of the modular partition system.
d. Install modular partition system after the building is enclosed and conditioned including completion of HVAC equipment, fire suppression system, lighting, adjacent ceilings and base building finishes in a sequence that allows final electrical connection, voice data/communications to be completed during or after installation of the modular partition systems.
i. Coordinate modular partition installation with ceiling, floor finish, and specified wall base (modular partition standard base, applied base, or integral base installation).
e. Floor and base finishes may be completed before installation of modular partition system unless coordinated with the manufacturer ahead of time through the Shop Drawing process.
1.4 SUBMITTALS
A. Product Data:
a. Provide manufacturers standard product information for each type of product indicated.
B. Shop Drawings:
1. Where required by the local building authority, provide structural analysis data and calculations for installed products to demonstrate compliance with design loads, signed and sealed by licensed professional engineer registered in the jurisdiction of the project.
2. Provide manufacturer’s architectural plans, elevations, sections, connection and attachment details, finish schedule, reflected ceiling plans, doors and hardware schedule, electrical and mechanical requirements, schedules, and locations.
3. Include field measurements of existing construction, future construction, finished width and height of partitions and associated components.
a. Manufacturer’s authorized representative shall undertake field measurements to show relevant adjacencies in Shop Drawings. Site conditions, base building construction, and required clearances are to be reviewed and approved by the Interior Designer, including exiting, life safety, location of building service devices, and other affected trades through Shop Drawings to identify and prevent potential conflicts.
b. Where field measurements are not possible, hold-to and control dimensions must be coordinated and agreed upon by all parties through the Shop Drawing process before manufacturing begins.
C. Coordination Drawings:
1. Provide shop drawings for coordination between trades upon request.
2. Provide architectural plans locating modular partitions within the base building, including finishes and construction of surfaces the modular partition system will interface with or connect to.
3. Provide reflected ceiling plans, drawn to scale, to show penetrations and ceiling mounted items to be coordinated with modular partitions and associated system components.
4. Structural: coordinate structural connections to base building and generate engineering calculations where required by the local building authority.
5. Electrical: Coordinate electrical components with final circuited electrical engineering documents.
D. Samples: Provide manufactures standard size samples for verification of support system and each type, color, and texture of exposed finish, full thickness and the following minimum sizes:
1. Extrusion Components.
2. Tile Finishes.
3. Linear Trim and Base.
4. Door Face Finishes.
5. Glazing.
E. Provide product data sheets for all types of Hardware and Accessories.
F. LEED Submittals:
1. MRc4.1 and MRc4.2 Recycled Content: Product Data and costs indicating percentages by weight of post-consumer and pre-consumer recycled content.
2. MRc5.1 and MRc5.2 Regional Materials: Product Data and costs indicating percentages by weight of regional materials as defined by LEED for the project type.
3. MRc6 Rapidly Renewable Materials: Manufacturer certificates.
4. MRc7 Certified Wood: Manufacturer certificates.
5. IEQc4.1 Low Emitting Materials - Adhesives and Sealants: Product data for field applied adhesives including printed statement of VOC content.
6. IEQc4.2 Low Emitting Materials - Paints and Coatings: Product data for field applied paints and coatings, including printed statement of VOC content and chemical components.
7. IEQc4.4: Product data for each composite wood product and adhesive used indicating bonding agents and adhesives contain no urea formaldehyde.
8. IEQc8.1 Daylight and Views: Architectural and modular partition drawings and additional documentation as required by LEED
9. IEQc8.2 Daylight: Architectural and modular partition drawings, product data, and additional documentation as required by LEED.
10. Innovation in Design (ID): documentation as required by LEED.
11. Pilot Credits: Provide documentation as required by LEED for the following:
a. Life Cycle Assessment (LCA).
b. Environmental Product Declaration (EPD).
c. Health Product Declaration (HPD).
d. Life Cycle Impact Reduction.
e. Acoustic Measures.
f. Lead Free Content.
G. Product Test Reports, Solid Partitions: Based on evaluation of comprehensive tests performed by a independent qualified testing agency:
1. Evaluation/Certification Reports:
a. ICC ESR (Evaluation Service Report), ESR1947 (reissued 2007):
Provide evidence of compliance with structural performance requirements and relevant building codes.
b. Intertek Certification demonstrating compliance with UL 1286 Office Furnishings.
c. UL QQXX - Sections and Units for electrical components.
d. OSHPD Preapproval of Manufacturers Certification.
e. IRR-1012 - Intertek (Warnock-Hersey) Solid Wall Code Evaluation
Report / Listing.
H. Maintenance Data: Provide maintenance data for incorporation into operation and maintenance manuals.
1.5 QUALITY ASSURANCE
A. Qualifications:
1. Manufacturer Qualifications: Manufacturer shall specialize in designing and manufacturing modular partitions of the quality and complexity required for this project with a minimum of 10 years documented successful experience.
Manufacturer shall have production facilities capable of meeting contract requirements for single-source responsibilities and warranty.
2. Installer Qualifications: Certified by the manufacturer.
B. Certifications:
1. Sound Transmission Characteristics: Testing to be performed by a qualified independent testing agency in accordance with performance requirements above.
C. Pre-Installation Conference:
1. Meet at the project site minimum 1 week prior to Shop Drawing approval and prior to beginning installation. Meeting shall include authorized representatives of the Owner, Architect, base building contractor and all trades whose work will interface with installed systems.
1.6 DELIVERY, STORAGE AND HANDLING
A. Do not deliver or install modular partitions until spaces are enclosed and weather-tight, wet work is complete and dry, work above ceilings is complete, and HVAC system is operational and able to maintain ambient temperature and humidity conditions at occupancy levels for the remainder of the construction period.
B. Ship system components in manufacturer’s standard packaging. Maintain air circulation during shipment. Do not allow packaging to get wet or develop condensation.
C. Deliver materials to project site or offsite warehouse as directed by the Contractor or Owner as applicable, and in accordance with the manufacturer’s instructions in original unopened and undamaged packages. Packages shall be labeled with manufacturers name, brand names, size, finishes, and placement locations.
D. Store in a clean, dry, secure space to protect from damage during construction activities.
Minimize or eliminate storage period by coordinating with construction schedule.
E. Handle in accordance with the manufacturers instructions.
1.7 PROJECT CONDITIONS
A. Environmental Limitations: Do not deliver or install system and components until building is enclosed and finishing operations are complete, including adjacent ceiling and floor covering installation and painting.
B. Temperature and humidity shall be maintained to final occupancy standards. Installation areas shall be climate controlled between 60 and 90 degrees F (15.5 and 32.2 C) with Relative Humidity maintained between 25 and 55 percent.
1.8 WARRANTY
A. Provide manufacturers standard, limited, transferable warranty executed in the name of the Owner. Guarantee the site assembled modular structure, panel system and components are free from defects in material and workmanship.
1. Warranty Period, Modular Partition System: 10 year limited warranty.
Part 2 Products
2.1 MANUFACTURERS
A. DIRTT Environmental Solutions;
1. Website: www.dirtt.net
2. GSA Schedule:
a. Contract: GS 07F 0005T.
b. CCR#: 73193726.
B. Steelcase Demountable Partitons
1. Website: http://www.steelcase.com
2. GSA Schedule:
a. Contract: GS 27F 0014V
b. DUNS: 00601-6547
C. Substitutions: Not permitted without demonstrating compliance with aesthetic effects shown in the drawings, performance requirements and lead times specified above.
2.2 SYSTEM DESCRIPTION
A. Factory assembled, site installed, moveable, demountable, reusable interior solid and glazed partitions, including structure, face mounted finished tiles, modular and non-modular metal framing and doors to accept a variety of millwork, finishes, building services components, technology, and accessories.
B. System is floor-supported, floor-to-ceiling site constructed in configurations shown on the Shop Drawings. Top channels hold modular partitions in place and accommodate height adjustments to suit floor-to-ceiling dimensional variations and similar site specific requirements.
http://www.dirtt.net/
1. Where modular partitions are not clipped to ceilings or other overhead construction, additional structural review and system engineering will be required by the manufacturer.
C. Panel Attachment: Unitized aluminum frame assembly to support face mounted tiles in orientation and module increments as shown on the Drawings.
D. Partially Unitized Solid Wall system shall be comprised of modular components which can be disassembled, relocated / field cut and substantially reused.
E. Face tiled finishes applied to lightweight frame system, may be monolithic or segmented with the ability to span off-module, or across multiple frames in segments or monoliths, vertically and horizontally.
F. Manufacturer shall provide integrated strategy for accommodating accessory channels and reveals integrated into the structural frame allowing universal horizontal alignment to support millwork, furniture, storage and accessories without defacing or damaging face tile or structural frame.
1. Materials manufactured by others shall not exceed the modular partition manufacturer’s limitations or tested performance.
G. Manufacturer shall provide ability for independent configuration / finish. Each side of wall must have the capability for variable aesthetic and function to suit different requirements.
This will allow for the one side of the wall to have a totally independent function than the other to meet each organizations requirement.
H. Electrical and Communications Access: 1 inch (25 mm) to 3 inches (75 mm) clear wall cavity for accessible from either side of partition by removable face tiles.
I. Modular partition manufacture shall allow for adaptability and retrofitting of hardware for future division of partitions, tiles, or supports to the greatest extent practical.
2.3 MODULAR PARTITIONS FRAMING
A. Framing for Solid and Face Tiled Partitions:
1. Material: Aluminum extrusions, 6063T6 aluminum alloy, thickness engineered to meet performance requirements specified above.
2. Vertical Support Spacing: 6 inch (150 mm) minimum to 48 inch (1219 mm) maximum.
3. Ceiling Track: Continuous, with intermittent breaks for pass through of building services or structural components.
4. Floor Track: Modular with wall frames inclusive of carpet grippers or floor tape (non-seismic) or continuous with floor anchor attachment (seismic) stopped at doorways and pass-throughs.
5. Bracing: as required to meet structural performance.
6. Fasteners: Zinc Plated Steel Type F Screws unless otherwise indicated on engineered shop drawings.
B. Framing for Glazed Partitions:
1. Same as solid panel framing with customized spacing as shown on the Drawings. Maximum spacing 60 inches (1524 mm).
C. Frame Bases:
1. Provide frame bases with provisions for 1-1/2 inch (38.1 mm) height adjustment to accommodate floor slab variances.
2. Provide a leveling mechanism for making fine adjustment in height over adjustment range of the product.
2.4 FACE MOUNTED FINISHED TILES
A. Panel Construction:
1. Standard Solid Tile Material: Medium Density Fiber Core (MDF).
a. Provide with the following premium options. Coordinate with manufacturer as required, all options may not be able to be combined.
i. No Added Formaldehyde (NAF).
ii. Forest Stewardship Council (FSC) Certification.
iii. Flame Retardant Type (MDF) where required.
2. Thickness:
a. Solid Tiles: 1/2 inch (13 mm).
b. Glass Tiles: 1/4 inch (6 mm) with aluminum mounting rails to maintain alignment with adjacent finishes.
3. Widths: As shown on shop drawings.
4. Height: As shown on shop drawings.
5. Finishes: As specified below and as shown on the Drawings.
B. Reveals:
1. Classic: 0.35 inch (9 mm);
2. Enzo: 0.15 inch (4 mm).
2.5 GLASS AND GLAZING
A. Typical: Tempered glass minimum thickness 6 mm (1/4 inch) to ASTM C1048, Kind FT (fully tempered), Condition A (uncoated), Type 1, Class 1 (transparent), Quality q3.
1. Back Painted Glass: As specified with finishes below.
B. Laminated Glass: To ASTM C1172, Kind LA fabricated from two nominal 3 mm (1/8 inch) pieces of Type 1, Class 1, Quality q3, flat annealed transparent glass conforming to
ASTM C1036.
C. Glass Types:
1. Glass Type GLS-1: Tempered Glass as specified above
2.6 DOORS AND DOOR HARDWARE
A. General:
1. Coordinate security system components to be provided by others with Modular partitions manufacturer through the Shop Drawing process.
2. Provide uneven leaf doors as documented on Shop Drawings.
B. Glazed Aluminum Doors: Manufacturer's standard stiles and rail door, pivot operation, glazed aluminum doors.
1. Door Thickness: 1-15/32 inches (43 mm) thick.
2. Stile Width: 4 inches.
3. Top Rail Height: 4 6 inches.
4. Bottom Rail Height: 7-7/8 inches AFF.
a. Provisions for ADA bottom rails as determined by the design professional of record.
5. Adjustability: Provide door skirt to accommodate varying floor levels.
6. Door Height: As noted on shop drawings. Maximum height 10 feet (3 meters).
7. Glazing: Tempered glass, 6mm (1/4inch) thick, custom finish.
8. Hardware Reinforcement: Factory milled by modular partition manufacturer to suit glass and hardware supplied by others as shown on show drawings.
[OR]
2.7 DOOR FRAMES
A. Pivot Door Frames: Manufacturer's standard aluminum frame single door , reversible, factory milled to receive hardware, for 1-15/32 inches (43 mm) +/- 1/16inch (1.5mm) doors.
1. Door Module Size: 36”w by 84”h.
a. Finished door width is equal to module width less 2 inches (51 mm).
2. Configuration: Header, jambs and pivot hardware. Single door frame width not to exceed 44 inch (1118 mm) wide module.
3. Hardware Preparation and Reinforcement: Milled, reinforce, drill and tap frames at factory to receive specified hardware in accordance with the contract hardware schedule and templates.
4. Frame Height: Jambs shipped over length (height) by 2 inches (51 mm), for field cutting to suit opening height for proper alignment with adjacent frames.
5. Factory notched and drilled jambs for ceiling track and manufacturer’s standard header attachment.
6. Extrusion Profile: Rectilinearprofile to match any adjacent unitized glass frames.
7. Seals: Manufacturer's standard.
2.8 ACCESSORIES
A. Connections and Supports: Manufacturer's standard connections and supports that connect and release from floor and ceiling without damage using carpet grippers and ceiling track clips, with exception of the following conditions: bulkhead (drywall ceiling), seismic conditions, electrical or service feeds, physical connections to base building (where required).
B. Panel Joint Closure: Manufacturer's standard, capable of closing up to a 25 mm (1 inch) gap between demountable partitions and base building elements.
C. Trim: Continuous and modular, factory finished, snap on type; field cuttable for variations in floor and ceiling levels.
1. Base Trim Profiles: Recessed; removable to access leveling mechanisms.
2. Ceiling Trim Profile: Recessed; adjustable to accommodate up to a 12 mm (1/2 inch) gap between demountable partitions and base building elements.
3. Wall Trim Profile: Recessed; adjustable to accommodate up to a 12 mm (1/2 inch) up to 25 mm (1 inch) gap between demountable partitions and base building elements.
4. Tile to Tile Profile: As detailed.
5. Colours: As selected by Interior Designer from manufacturer's full range.
D. Brackets:
1. Manufacturer's brackets, supports and accessories for complete installation of system's furniture components, architectural millwork, audio visual equipment, and paper accessories.
2. Provide bracket design to enable other system furniture to mount to modular partitions, on or off module.
2.9 FABRICATION
A. Modular Tiles:
1. Unless otherwise indicated on shop drawings, factory assembled frames with 1inch (25 mm) insulation, base track and levellers; face mounted tiles installed to frames on site.
B. Components:
1. Fabricate components for installation with concealed fastening devices and pressurefit members that will not damage ceiling or floor coverings. Exceptions:
Drywall ceiling, seismic applications and doors against base building require screw holes in base building for proper fastening.
2. Fabricate for installation with manufacturer’s standard seals at floor and other locations where partition assemblies abut fixed construction and for installation of sound attenuation insulation in partition cavities.
2.10 FINISHES
A. Protect finishes on exposed surfaces from damage during shipping.
B. Appearance of Finished Work:
1. Finishes shall match approved samples.
2. Variations in natural finishes such as stone and wood shall be reviewed and accepted in accordance with industry standards.
C. Frame Finishes:
1. Clear Anodized Aluminum: AAMA 611, AAM12C22A31, Class I.
D. Factory Applied Panel Finishes: Make joints only where total length exceeds maximum manufactured length. Joints and reveals as indicated on approved Shop Drawings.
1. Paint Finish (PNT):
a. Series: Paint match.
b. Coating Type: UV cured water based paint, Chromacoat or approved equivalent.
c. Color: TBD.
d. Paint Match Manufacturer: Sherwin Williams.
e. Paint Match Description: painted to match existing walls.
f. Paint Match Color number: TBD.
E. Frameless Back Painted Glass:
1. Magnetic Back Painted Glass (MGLS):
a. Series: Standard.
OR:
2. Magnetic Markerboard: Porcelain enamel, balanced, high-pressure laminated, porcelain enamel-faced tiles, of three ply construction consisting of face sheet, core material, and backing.
a. Porcelain Face Sheet: Prefinished 28 gauge steel adhered to substrate.
b. Core Material: 1/2 inch (13 mm) thick MDF.
c. Color: White.
F. Door Finishes:
1. Clear anodized aluminum; AAMA 611, AAM12C22A31, Class I.
Part 2 Execution
2.1 EXAMINATION
A. Verify field or hold-to control dimensions before fabrication of modular partitions.
Coordinate fabrication schedule with construction schedule and progress to avoid delay in the work.
B. Examine all adjoining work including work by others. Do not proceed with fabrication or installation until unsatisfactory conditions are corrected.
2.2 PREPARATION
B. Locations to receive modular partitions shall be inspected for compliance with manufacturer’s requirements.
C. Site floor conditions must be surveyed to determine the nature of floor level and determine where special conditions exist beyond manufacturer’s standard leveling capabilities of 1-1/2 inch in 4’-0” (38.1 mm in 1219 mm).
D. Field conditions and pre-existing installations by others which may adversely affect installation or exceed the manufacturer’s limitations shall be corrected before installing modular partitions.
2.3 INSTALLATION (TYPICAL PROCESS)
A. Installation of modular partitions system shall be completed by a manufacturer certified installer.
B. Install system level, plumb, and aligned.
C. All building services shall be installed and connected to the base building systems by licensed subtrades. All building services shall be inspected by authorized trade representatives and Authority Having Jurisdiction in the presence of a manufacturer representative. Coordinate with all affected parties as required.
D. Installation sequence as determined by the certified installer and coordinated with the General Contractor based on project conditions.
2.4 CLEANING
A. Upon completion of installation, modular partition components and finishes shall be cleaned in accordance with the finish manufacturer’s instructions. Alkaline or abrasive agents shall not be used. Avoid scratching or marring finishes.
2.5 PROTECTION
A. Protect from damage through the duration of construction activities.
2.6 DEMONSTRATION | TRAINING
A. Manufacturer’s Distribution Partner will be responsible to provide general product training to the Owner or their outsourced operations team at time of installation as well as conduct a comprehensive training session(s) to convey the methodology, and assembly of the modular partitions to sustain general operational maintenance by the Owner’s personnel with clearance over the facilities lifetime.
1. Reconfiguration and modifications shall comply with manufacturer’s warranty requirements. Extensive or unusual changes will require additional Shop Drawings and manufactured components.
END OF SECTION
Steelcase Design Details
Stile and rail door shown here.
Frameless glass is not shown but submitted in this budgetary quote.q
TYPICAL
OFFICE FRONT
TYPICALTYPICAL
ELEVATION
TYPICAL
ELEVATION
Concept Imagep g
SCOPE TYPICAL
INCLUDES STOREFRONTS &
CROSS RUN WALLS
Concept Imagep g
Installation Notes:
• All work to be performed by non-union labor during normal business hours.
• Davis Bacon Wage requirements have not been accounted for.
• Permit fees to be determined by the county and is not included. Please have demountable partitions included on the drawings that the GC submits for the building permit.
• Pricing assumes dedicated access to the loading dock and elevators during Normal Business hours of receiving and trash removal. Pricing EXCLUDES stair carry or crane lift.
• Arbee will need free and clear access to the space during delivery and installation.
• Hard wiring connections to the building to be provided by others.
• Pricing assumes product to ship from manufacturers for just-in-time deliveries to avoid the need for offsite storage.
• A walkthrough will be performed for punch list generation and resolution.
• Direct path and work areas will be wiped down and broom swept upon completion.
• A certificate of insurance will be provided upon award and order of product (if required).
• Costing for field cutting at window sill conditions has been included in the pricing.
• Project Management is included.
Exceptions
• Connection termination of electrical, devices or cover plates. Removal or relocation of electrical devices. Electrical cutouts, devices, wire or wiring, conduit, boxes are not included in this proposal.
• Unless otherwise noted all fixed surface intersections are assumed flushUnless otherwise noted, all fixed surface intersections are assumed flush.
• Door hardware lever set TBD and door stops are included.
• ARBEE is not responsible for change in ceiling or floor condition after site check and prior to installation.
• Excluded is the relocation or demounting of window treatments blinds sills and any fixed or temporary equipment at the wall• Excluded is the relocation or demounting of window treatments, blinds, sills and any fixed or temporary equipment at the wall connection points either on the floor, walls or ceiling
• Excluded is the cost for carry-up or crane install required for elevator exclusion.
• Electrical or data; cutouts, wiring, devices, cable routing, fixtures, or any additional electrical (not otherwise indicated), data or i d i l d i l d d f hi lsecurity devices or related items are excluded from this proposal.
• Pricing subject to field survey, finish selections and installation schedule.
• Pricing does not include fuel surcharges at this time.
General Proposal Notes:
1. Our proposal provides solutions for your work environment and is derived solely by review of the RFP package and counts based on the drawing s submitted and subsequent communications.
2 LEAD-TIMES: Lead-times are approximately 6-8 weeks but can vary depending upon the manufacturers back log at the time the2. LEAD-TIMES: Lead times are approximately 6 8 weeks but can vary depending upon the manufacturers back log at the time the order is placed. The lead-time begins once the order is entered. Orders must include the client signed approval of shop drawing, finishes.
3. In order to provide DOL the best available pricing, Arbee developed pricing based on products shipping from the manufacture direct to site based on a 53’ tractor trailer, with trailer being able to have clear access to the loading dock. Should smaller additional trucks and labor be needed based on the information provided to us an additional labor fee will be incurred Thisadditional trucks and labor be needed based on the information provided to us an additional labor fee will be incurred. This amount is NOT shown herein.
4. Pricing indicated assumes an award of predominantly all of the project. Arbee assumes the right to change the pricing based on final manufactures awarded and quantities.
5 A d l k i i l d d i h d l5. A dealer markup is included in the dealer cost .
6. Change orders will be priced based on magnitude of change requested.
7. All pricing is subject to change based on changes in fabrics, finishes, product componentry, and project scope.
8. Sales tax is included in this proposal. If this is tax exempt, Arbee will need a letter of authorization or retail sales tax certificate.
1. Arbee Associates’ process for placing an approved order is as follows:
A. Arbee Associates may or may not waive the standard 50% deposit requirement.
B. The client must sign the quotation, Arbee Terms & Conditions, final drawings and finish sheet.e c e t ust s g t e quotat o , bee e s & Co d t o s, a d a gs a d s s eet
DIRTT Design Details
Appendix E
Cut Sheets
DORMA
LOW ENERGY
OPERATORS
Features
Slide track arm available for inswing applications.
Full length header available on request.
5.5" W × 5" H Extruded Aluminum Header (140 × 127 mm).
For inswing & outswing doors.
Scissor-arm for inswing & outswing applications.
Finishes
204-R1 clear anodized.
313-R1 dark bronze anodized.
Special finishes available (custom anodized, paint, architectural metal cladding).
Standards
ETL listed for US and Canada (UL325).
Full compliance with ANSI A156.19 – American National Standard for Power Assist and Low Energy Power Operated Doors.
Full compliance with the Americans with Disabilities Act of 1990.
NFPA 252 90 minute fire rating when used with rated door and hardware.
ED700 LOW ENERGY OPERATOR
Barrier-free Access
The DORMA ED700 Low Energy Operator is the perfect solution for barrier-free access applications.
Simple and easy to install, the ED700 provides many features and functions to make existing doors easily accessible.
The DORMA ED700 is custom ordered to match the application. All common applications for outswing and inswing doors—either with push arm or slide track arm for tight side clearance —can be adapted for barrier-free access.
Extruded aluminum covers in custom lengths are avail-able to match aesthetically with the door frame.
The ED700 may be used for door widths up to 48" (1220 mm) and a maximum weight of 200 lb (91 kg).
For best accessibility, the operator can open the door up to an opening angle of 110°.
LEFT
HAND
REV BEVEL
(LHR)
LEFT
HAND
IN SWING
(LH)
RIGHT
HAND
IN SWING
(RH)
AS VIEWED FROM EXTERIOR
RIGHT
HAND
REV BEVEL
(RHR)
Door Handing Definition
ED700 LOW ENERGY OPERATOR
DORMA
DORMA LOW ENERGY OPERATORS
Brockway-Rebekah-Y Rectangle
Settings and Adjustments All major adjustments are easily accessible on the control unit allowing correct settings for varying door and pedestrian requirements.
Main adjustments are as follows:
Open speed.
Time delay (hold open time, 1–30 seconds).
Close speed.
Open check speed.
Open force.
Electrical Requirements 120 VAC, 50/60 Hz, 5 A minimum.
Options for Activation Pushbutton (momentary actuation opens door;
time-delayed closing).
Internal Push-&-Go (Slight push of door will initiate powered door opening).
Card Readers.
Power Assist.
Remote Controls.
3-Position Door Control Switch
OFF (easy manual operation).
ON (low energy mode operation).
OPEN (door fully opens and remains).
Built-in Power Supply for Sensors
Optional Accessory Interface
Motion sensor (door opens and remains until sensor zone clears; time-delayed closing).
Presence sensor (swing area protection; prevents closed door from opening/ open door from closing).
Built-in lock-out function and support for dual-state overhead safety sensors.
Door-Mounted Sensors (Approach/Door Open;
Swing Side/Door Inhibit).
PLAN
SCALE: 2.4" = 1'0" (1:5)
ELEVATION
SCALE: 2.4" = 1'0" (1:5)
1-1/2"
TYP
VERTICAL SECTION
SCALE: 3" = 1'0" (1:4)
5-1/2"
2-1/8"
1-31/32"
UNIT WIDTH
(= DOOR WIDTH + 3")
INCOMING 120 VAC
(OPPOSITE PIVOT)
5-1/2"
5"
3/4"
PLAN
SCALE: 2.4" = 1'0" (1:5)
ELEVATION
SCALE: 2.4" = 1'0" (1:5)
1-1/2"
TYP
VERTICAL SECTION
SCALE: 3" = 1'0" (1:4)
5-1/2"
1-7/8"
1-31/32"
UNIT WIDTH
(= DOOR WIDTH + 3")
INCOMING 120 VAC
(OPPOSITE PIVOT)
5-1/2"
5"
1-3/16"
Surface Applied Outswing Scissor-Arm (Push Application)
Surface applies the operator to the door frame with a push arm assembly attached to the top door rail.
Surface Applied Inswing Scissor-Arm (Pull Application) (Standard)
Surface applies the operator to the door frame with push arm assembly attached to the top door rail.
LEFT
HAND
REV BEVEL
(LHR)
LEFT
HAND
IN SWING
(LH)
RIGHT
HAND
IN SWING
(RH)
AS VIEWED FROM EXTERIOR
RIGHT
HAND
REV BEVEL
(RHR)
DORMA LOW ENERGY OPERATORS
ED700
Configurations
CUTTING EDGE TECHNOLOGY
ED700 Features & Functions
ED700 CUTTING EDGE TECHNOLOGY: FEATURES & FUNCTIONS
DORMA
Brockway-Rebekah-Y Line
Brockway-Rebekah-Y Line
DORMA LOW ENERGY OPERATORS
DORMA offers the ED400-IG Automatic Floor Closer for applications that need to both meet access require-ments and main tain a classic look, such as an arched door or an all-glass façade. This revolu tion-ary operator conceals the auto matic com ponents in the floor near the door threshold.
The ED400-IG functions in either low energy or full power mode, and can be used in both new construction and retro-fit applications. DORMA partnered with Opcon Manufacturing Systems to construct this closer, which directs energy generated by the ED400 drive unit to the pivot in a rotating motion, thus allowing consistent, smooth operation.
The install box that stores the operator is completely weather proof and is only 7" deep. All ED400 operator functions, such as Push & Go, Power Close, and Lock Interface, are fully available in this appli cation, which DORMA is nonetheless able to offer at a value-conscious price.
ED400-IG CONCEALED IN-GROUND FLOOR CLOSER
Dual Mode: Low Energy or Full Power
ED400-IG CONCEALED FLOOR CLOSER
Powered by linear magnetic drive technology (LMD), the MAGNEO entrance system is designed for any modern interior. Innovative LMD technology ensures that the MAGNEO is safe, reliable, whisper quiet, and resistant to wear.
DORMA MAGNEO is ideal for both new and retrofit interior applications. Its modern design and easy operation make it an attractive and efficient way to update both the function and appearance of existing interior doorways.
The versatile MAGNEO meets all safety requirements for low energy applications. Its extra sensitive operation instantly detects any obstruction. Activation is achieved via touchless design push plate, radio remote control, or traditional infrared motion detectors.
The DORMA ED100 and ED250 are compact next generation electro-mechanical swing door operators.
Inno vative engineer ing makes them safe, reliable, and energy-efficient at any level of traffic and in variable atmos pheric con-ditions. Their modular design allows them to be pre-configured with plug-ins for specific applica tions.
Their sleek, minimalist Contur profile makes them a perfect fit for any application, interior or exterior.
Unlike conventional electro-hydraulic operators, the ED100 and ED250 are able to respond automatically to changes in the surrounding environment. A state-of-the-art drive system and built-in sensors can quickly adjust how the unit operates, boosting power when required to open and close reliably and consistently.
A wide array of applications can be realized due to built-in functions and options including wind-load control, mechanical coordinator, automatic power assist, sensor/lock timing, and more.
Universal modular design and high-tech functionality combine with ultra-compact form and award-winning Contur aesthetics to make this operator a beautiful way to automate easily without drawing unwanted attention.
ED100 & ED250 COMPACT SWING DOOR OPERATORS
Low Energy/Full Energy
DORMA ED100:
for doors up to 220 lb (100 kg)
DORMA ED250:
for doors up to 550 lb (250 kg)
ED100/ED250 SWING DOOR OPERATORS / MAGNEO SLIDING ENTRANCE SYSTEM
DORMA MAGNEO SLIDING ENTRANCE SYSTEM
Linear Magnetic Drive Technology (LMD)
DORMA LOW ENERGY OPERATORS
.1
C
T
.5 M
U
S A
DORMA Americas 924 Sherwood Drive Lake Bluff, IL 60044 Toll Free: 877.367.6211 Fax: 877.423.7999 automatics@dorma-usa.com www.dorma.com
Product Specifications
Product Size 24" X 24" Tile (18" x 18" and 36" x 36" also available)
Total Product Thickness 0.315 in (8.0010 mm)
Pattern Scale Large
Pattern Type Linear
Collection Zenbu Collection / Jhane Barnes
Coordinating Group Coordinate Group 5
Construction Stratatec® Patterned Loop
Primary Backing Non-woven synthetic fiber
GSA Yes
Blink Yes
Price Range $$$
Face Weight 20 oz/sq yd 678 g/sq m
Gauge 5/64 50.4 rows/ 10 cm
Stitches Per Inch 9.2 stitches / inch 36.2 stitches/10 cm
Pile Height Average 0.187 inch 4.8 mm
Fiber System Dynex® Nylon
Dye Method Yarn Dyed
Soil/Stain Protection Ensure
Pattern Match Not required
Colorfastness to Light > 4 after 60 hours (AATCC 16E)
Fluorine Minimum 500 ppm (CRI TM-102).
Third Party Certification NSF-140 Platinum
Electrostatic Propensity 2.0 kV (AATCC 134); Permanent Conductive Fiber
Surface Flammability Passes CPSC FF 1-70 (ASTM D-2859)
Smoke Generation Less than 450 (ASTM E-662)
Wet Spread Backing specific Tandus Adhesives
Environmental Attributes
Total Recycled Content 52.6% (28.9% Pre-Consumer; 23.7% Post-Consumer)
Recycled Content Yes
CRI Green Label Plus Certification GLP1366
Antimicrobial Chemicals No antimicrobials (EPA Registered pesticides) added to product (ASTM E2471-05)
Performance Testing
Flooring Radiant Panel Class 1 (mean average CRF: 0.45 w/sq cm or higher) (ASTM E-648)
Installation Methods
Installation Method Quarter Turn / Random / Vertical Ashlar - 18" X 36"
Warranty Information
Warranty Information Lifetime limited warranty against excessive surface wear, static, delamination, edge ravel, zippering and backing resiliency loss.
Haiku II #02127
Zenbu Collection / Jhane Barnes fixed wall mounts
SPECIFICATIONS
TECHNICAL DRAWINGS
WHAT YOU NEED TO KNOW
RECOMMENDED ACCESSORIES
FEATURES
59CliCk chiefmfg.com
CAll 800.582.6480
FAX
877.894.6918
LSM 37 - 63" mICRo-adjustablE mount
Controlzone™ leveling Industry-first feature allows post-installation fine tuning of height and leveling.
Centerless™ shift Provides up to 17.5" (445 mm) of post-installation lateral shift – 8.75"(225 mm) left/right of uprights – for limitless centering capabilities.
CliCkConneCt® Hear an audible click when the screen safely engages with the mount. a built-in cable stand provides easy access under the screen.
Customizable aCCessory system a full line of supporting accessories can be integrated with the mount, extending the same adjustment benefits to the entire configuration.
multiPle installation oPtions Can be installed on 12" (305 mm) on-centers up to 32" (813 mm).
Depth from Wall 1.96" (50 mm)
Max Lateral Shift 17.5" (445 mm)
Dimensions 16.5 x 34.44 x 1.96" (HxWxD) (419 x 875 x 50 mm)
Max Mounting 19.88" (505 mm) Pattern (H,W) 34.25" (870 mm)
Weight Capacity 200 lbs (90.7 kg)
Color Black
For a complete list of FUSION accessories see pages 86 - 88.
FVS250 n 12" Video Conferencing Shelf - above
FcS100 n Single Component Shelf
- below
FLR100 n Left/Right Speaker Adapter
1 2
34.44" (875 mm)
15.1" (383 mm)
21.3" (540 mm)
16.52" (420 mm)
1" (25.4 mm) 1.52"
(38.5 mm) 1.96"
(50 mm)
FUSION® SERIES
LSa FUSION Series Wall Mount
– For tVs 37–63"
OthER pROdUct OptIONS
RLF2
FIT™ Series Low-Profile Hinge Mount
– For tVs 32–52"
RXF2
FIT™ Series Low-Profile Hinge Mount
– For tVs 40–63"
| ModularPartitions - Edited |
| DOL_FP ILAB_Phase 2_00_01 |
| DOL_FP ILAB_Phase 2_01_02 |
| DOL_FP ILAB_Phase 2_02_03 |
File details come from the government source that posted it. Updated .