Facility_Planning_Report_(Vol._2).pdf

PDF 21 MB Posted

Attached to
Operation of the Sierra Nevada Job Corps Center
Solicitation number
DOL-ETA-16-R-00050
Issued by

About this file

Facility Planning Report (Vol. 2)

View the file

Other files

File Type Posted
Amendment_10.pdf PDF
Amendment_9.pdf PDF
Amendment_8.pdf PDF
Amendment_7.pdf PDF
Amendment_6.pdf PDF
Amendment_5.pdf PDF
Amendment_4.pdf PDF
Amendment_3.pdf PDF
Outreach _Admissions _and_Career_Transition_Questions_(Revised).docx DOCX document
Amendment_2.pdf PDF
Outreach _Admissions _and_Career_Transition_Questions.docx DOCX document
Amendment_1.pdf PDF
Updated_Collective_Bargaining_Agreement.pdf PDF
Pre-proposal_Conference_Sign-in_Sheet.pdf PDF
Vehicle_Listing.doc DOC document
Collective_Bargaining_Agreement.pdf PDF
Property_Summary_Report.pdf PDF
Attachment_J.3__(Financial_Display_by_Year).docx DOCX document
Facility_Planning_Report_(Vol._1).pdf PDF
Attachment_J.4_(Staffing_Chart).docx DOCX document
Attachment_J-8_(Statement_ _Acknowledgment).docx DOCX document
Attachment_J.2_(Statement_of_Financial_Capability).docx DOCX document
Utilities_Usage.pdf PDF
Attachment_J-1_(Cost_Detail_Template).docx DOCX document
Attachment_J.6__(Subcontracting_Plan_Summary_Sheet).docx DOCX document
Inventory_Valuation.pdf PDF
Solicitation.docx DOCX document
Attachment_J.5_(Career_Technical_Skills_Training).docx DOCX document
Master_Itemized_Property_Report.pdf PDF
National_Staff_Compensation_Report.pdf PDF
Attachment_J-7_(Past_Performance_Questionnaire).docx DOCX document
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SIERRA NEVADA

Job Corps Center

Reno, NV

Facility Planning Report Volume II

Supporting Data

Final December 2014

Department of Labor/ Office of Job Corps

SIERRA NEVADA

Job Corps Center

Reno, NV

Facility Planning Report Volume II

Supporting Data

Final December 2014

Support Services Building 29

VOLUME I - PLANNING STRATEGY

Acronyms and Abbreviations Defi nition of Terms Executive Summary Exsting Site Plan Center Statistics Facility Survey Assement Results and Recommentdations

1.0 INTRODUCTIONS

• Objective and Scope

• Report Contents

2.0 EXISTING CONDITIONS

• Background

• Ownership

• General Site Conditions

• General Building Conditions

• Preventive Maintenance

• Facility Assessment by Function

• Environmental Management

• Resource Use/Conservation

• Sustainability

• Accessibility Standards

• Completed and Current Projects

• Health and Life Safety Issues

• Defi ciency Summary

3.0 PLANNING ANALYSIS

• Space Utilization Analysis

• Federal Real Property Assest Management

• Defi ciency Analysis

• Facility Condition Summary

• Building Condition by Function

• Planning Analysis Results and Conculsions

3.0 RECOMMENDATIONS

• Status of Previous Plan

• Proposed Plan

• Funded Not Corrected (FNC) Defi ciencies

• Summary of Proposed Plan

• Proposed Site Plan - Near Term

• Proposed Site Plan - Long Term

• Implementation Plan

• Summary List of National Projects

• Project Data Sheets

VOLUME II - SUPPORTING DATA

Acronyms and Abbreviations Defi nition of Terms Executive Summary

1.0 SITE LAYOUT AND PLANS

• Location Map

• Exisiting Site Plan

2.0 DESCRIPTIONS

• Buildings and Structures

• Space Utilization By Function

• NSF by Building

• Environmental Management Report

• Asbestos Report

• Radon Report

• Site Descriptions

• Building Descriptions

3.0 DEFICIENCIES

APPENDICES - CORRESPONDENCE AND REPORTS

Appendix A.

• Center Review Meeting Minutes

• Survey Brief

• Student Questionnaire

Appendix B.

• Life Safety Defi ciencies and List

Appendix C.

• O&M Defi ciencies List

Appendix D.

• Active Warranty List

Appendix E.

• FRPC Performance Measures Matrix

Acronyms and Abbreviations

ACRONYMS AND ABBREVIATIONS

A Amperage ABAAS Architectural Barriers Act Accessibility Standard ACM Asbestos-Containing Materials AFUE Annual Fuel Utilization Efficiency AHU Air Handling Unit ANSI American National Standards Institute ARRA American Recovery and Reinvestment Act of 2009 BTU British Thermal Units\ CAA Clean Air Act CCF Hundred Cubic Feet CCTV Closed Circuit Television CDC Child Development Center CDC Centers for Disease Control and Prevention CDP Career Development Period CDSS Career Development Service System CFL Compact Fluorescent Light Bulbs CFM Cubic Feet per Minute CIS Center Information System CMA Certified Medical Assistant CMMS Computerized Maintenance Management System CMU Concrete Masonry Unit CAN Certified Nursing Assistant CO Carbon Monoxide CO Contracting Officer COR Contracting Officer’s Representative CPP Career Preparation Period CRA Construction, Rehabilitation, and Acquisition CTP Career Transition Period CTS Career Transition Services

CTST Career Technical Skills Training (formerly Vocational Skills Training [VST])

CW Cold Water CWA Clean Water Act DDC Direct Digital Controls DFAM Division of Facilities and Asset Management DOL Department of Labor EISA Energy Independence and Security Act of 2007 EMT Emergency Medical Technician

EMT Electrical Metal Tubing (Conduit) EO Executive Order EPA U.S. Environmental Protection Agency EPCRA Emergency Planning and Community Right-to-Know Act (1986) EPMD Ethylene Propylene Diene Terpolymer ESC Engineering Support Contractor ESCIS Engineering Support Contractor Information System ESL English as a Second Language oF Degrees Fahrenheit FACP Fire Alarm Control/Annunciator Panel fc Foot Candle FNC Funded Not Corrected FOP Financial Operating Plan FRPC Federal Real Property Council FY Fiscal Year GAO General Accounting Office GED General Educational Development GFCI Ground Fault Circuit Interrupter gph Gallons per Hour GSA General Services Administration GSF Gross Square Feet HID High Intensity Discharge HP Horsepower HSD High School Diploma HTW Hazard and Toxic Waste HVAC Heating, Ventilating, and Air Conditioning HW Hot Water IBC International Building Code IMC International Mechanical Code ION Inventory of Needs IPC International Plumbing code KBTU Thousand British Thermal Unit/Gross Square Foot/Year kV Kilovolt kVA Kilovolt-Amps kw Kilowatt JCC Job Corps Center JCDC Job Corps Data Center JCH Job Corps Handbook kWh Kilowatt Hours LAN Local Area Network LED Light Emitting Diode LF Linear Feet MBH Thousand BTUs per Hour MBTU Thousand British Thermal Unit MWH Megawatt Hour MC Mission Critical MCF Million Cubic Feet MDNC Mission Dependent, Not Critical MDP Main Distribution Panel MLO Main Lug Only m/s Meters/Second MTS Manual Transfer Switch NEC National Electric Code NEMA National Electrical Manufacturers Association NEPA National Environmental Protection Act NFPA National Fire Protection Association NMD Not Mission Dependent NSF Net Square Feet OA Outreach and Admissions OBS On Board Strength OCM Office of Contract Management OIG Office of Inspector General O&M Operations and Maintenance OSHA Occupational Safety and Health Administration PA Public Address pCi Picocurie PV Photovoltaic PVC Polyvinyl Chloride RCRA Resource Conservation and Recovery Act RTU Rooftop Unit SGA Student Government Association SHPO State Historic Preservation Office SF Square Feet SPCC Spill Prevention, Control and Countermeasure SST Social Skills Training T5 Fluorescent Lighting Designation (High Efficiency)

T8 Fluorescent Lighting Designation T12 Fluorescent Lighting Designation (Low Efficiency TSCA Toxic Substances Control Act of 1976 TV Television TVSS Transient Voltage Surge Suppression UEV Unevaluated UFAS Uniform Federal Accessibility Standards UL Underwriters Laboratories USDA U. S. Department of Agriculture V Volt VCR Video Cassette Recorder VST Vocational Skills Training W Watt WAN Wide Area Network WBL Work-Based Learning WIA Workforce Investment Act WIB Workforce Investment Board

Defi nition of Terms

DEFINITION OF TERMS

Accessibility: The degree to which a product, device, service, or environment is available to as many people as possible. Accessibility can be viewed as the "ability to access" and benefit from some system or entity. The Federal Government is required to comply with published law (Architectural Barriers Act (ABA) of 1968 , American Disabilities Act of 1990), regulations and related standards. Accessibility laws and standards have evolved over the past 12 years. DOL now follows ABA Accessibility Standards for Federal Facilities (ABAAS) adopted by the General Services Administration.

Annual Operating Cost: This FRPC performance measure reflects the cost to operate each used asset and consists of lease costs as well as costs related to recurring maintenance, utilities, janitorial, and roads and grounds expenses (Source: FRPC 2012).

Building: In accordance with the FRPC 2012 Guidance for Real Property Inventory Reporting, a building includes an enclosure for human occupancy that serves a variety of functions (food service, education, recreation, medical/dental, storage, administration) and is likely to have full utility services (heating, cooling, etc.). A building typically is over 400 square feet.

Building Condition Rating by Function: Each building is assigned a building condition based on the physical condition of the building and the impact on the functional use of the facility. Three ratings are possible:

Good: The facility condition is not impacting the facility function. A facility can have deficiencies and still be considered good.

Fair: The facility condition is impacting the facility function and deficiencies are limited to less than 30% of the replacement value. Correction of the deficiencies would allow the facility to return to a good status.

Poor: The facility condition is significantly impacting the facility function and/or deficiencies are more than 30% of the replacement value. Generally a poor rating indicates a “gut renovation or total replacement/demolition would be required.

Building/Structure Ratings: Each building is rated according to three ratings (good, fair, and poor) based on evaluations of the structure, exterior, interior, mechanical, and electrical elements. Three ratings are possible:

Good: The facility condition is not impacting the facility function. A facility can have deficiencies and still be considered good.

Fair: The facility condition is impacting the facility function and deficiencies are limited to less than 30% of the replacement value. Correction of the deficiencies would allow the facility to return to a good status.

Poor: The facility condition is significantly impacting the facility function and/or deficiencies are more than 30% of the replacement value. Generally a poor rating indicates a “gut renovation or total replacement/demolition would be required

Construction Type: The International Building Code (IBC) construction classifications include the following:

Type I and II. Those types of construction in which building elements are of noncombustible materials, except as permitted in Section 603 and elsewhere in the code.

Type II and III. Any type of construction where the exterior walls are of noncombustible material and the interior building elements are of any material permitted by the code.

Type IV. This type (heavy timber, HT) is where the exterior walls are of noncombustible material and the interior building elements are of solid or laminated wood without concealed spaces.

Type V. That type of construction where structural elements, exterior walls, and interior walls are of any materials permitted by the code.

Contract Strength: The authorized number of students at a Center in accordance with the contract between the Region and Center Operator.

Deficiency: A deficiency at a Center represents the spectrum of conditions related to the Center’s mission and/or its physical, functional, or operational features do not meet related goals, standards, codes, or other measures of acceptability. Each deficiency at a JCC or CCC initially is categorized as one of the following three deficiencies: Program, Site, or Building:

Program: Program deficiencies address issues such as square footage shortages or the omission of amenities required or standard for the proper operation of a particular Job Corps function.

Site: Site deficiencies indicate adverse site and infrastructure conditions which negatively impact operations and environment (e.g., site lighting, sidewalks, roads, etc.)

Building: Building deficiencies indicate adverse conditions at the building level.

This element includes the substructure, shell, interior, services (plumbing, HVAC, fire protection, and electrical), and equipment and furnishings.

Deficiency Classifications (I to IV): Deficiency classifications are defined as follows:

Class IA - Deficiencies which address imminent life safety and health hazards.

Class II - Deficiencies which address code violations, however, do not represent imminent life safety and health hazards.

A - Deficiencies which violate code (Federal, State or Local) and may result in an interruption of center operations if not corrected.

B - Deficiencies which violate code (Federal, State or Local) and have no immediate impact on center operations if not corrected.

C- Deficiencies which are not in compliance for accessibility in accordance with the Architectural Barriers Act (ABA), Americans with Disabilities Act (ADA), Uniform Federal Accessibility Standards (UFAS), or other applicable standards.

Class III - Deficiencies which address facility repair, replacement or maintenance.

A - Deficiencies which if not corrected may result in an interruption of center operations.

B - Deficiencies which if not corrected will have minimal impact on center operations or can be mitigated through temporary measures until the deficiency is corrected.

Class IV – Deficiencies which address programmatic needs.

A - Deficiencies which if corrected produce substantial improvements in the quality of the learning and living environment.

B - Deficiencies which if corrected are desirable enhancements.

Deficiency Funding Status: The status of the deficiency included the following categories:

Funded deficiencies report indicates the funding year for funded Regional projects, which have dollar amounts shown, or deficiencies assigned to funded National and Regional projects without dollar amounts. Major Regional projects are equivalent to National projects but assigned to the Federal agency (e.g., U.S.

Department of Agriculture) that acts as the Center operator. All operations and maintenance (O&M) deficiencies are treated as funded through the Center Operators O&M contract within the Region.

Proposed deficiencies have been assigned to a proposed future National project.

Unfunded deficiencies are Regional projects unless or until they are assigned to a National project.

Deficiency Status: The deficiency status is tracked and updated during the three-year facility survey cycle, or as such deficiencies are corrected and reported. The status includes:

Uncorrected: Once a deficiency is identified, documented, reported, and assigned for correction, the deficiency remains uncorrected until such time that the deficiency is corrected, reported, and verified.

Corrected: A corrected deficiency is one that has been assigned, funded, corrected, reported, and verified. Typically, the ESC verifies completion of the deficiency through the facility survey or site visit. The Center also may report completion and provide verifiable evidence of the correction, subject to review by the ESC.

Funded Not Corrected: A deficiency that has been approved and authorized as a regional project through the CRA budget, emergency or supplemental funding, or the Life Safety Memo. Note: the funding may not have reached the Center yet as the first steps are a FOP allocation by the National Office and a contract modification by the Region.

No Longer Needed: A no longer needed deficiency is one that has been approved and funded as a Regional project, but due to subsequent circumstances, has been reported by the Center as no longer being required to be accomplished. This type of deficiency is verified and confirmed by the ESC and removed from the Funded Not Corrected deficiency category. The Center should take action with its Region to return the funds.

Facility Condition Index: This performance measure reflects the condition of each asset by comparing the current repair needs to the replacement value of the asset. The index is expressed as a percentage, with 100% being a facility with no repair needs.

Gross Square Foot: The sum of all areas on all floors of a building included within the outside faces of its exterior walls, including all vertical penetration areas, for circulation and shaft areas that connect one floor to another. Gross Area is computed by physically measuring or scaling measurements from the outside faces of exterior walls, disregarding cornices, pilasters, buttresses, etc., that extend beyond the wall faces. Exclude areas having less than a 3-foot clear ceiling height unless the criteria of a separate structure are met. Measured in terms of Gross Square Feet (GSF): GSF = Net Usable Area + Structural Space (Source: http://nces.ed.gov/pubs2006/ficm/).

Mission Dependency: The value an asset brings to the performance of the mission as determined by the governing agency. Specific elements of this category include (FRPC 2012):

Mission Critical - – Without constructed asset or parcel of land, mission is compromised.

Mission Dependent, Not critical (MDNC) - Does not fit into Mission Critical or Not Mission Dependent categories.

Not Mission Dependent (NMD) – Mission unaffected

Ownership (Owned vs Leased): If the property is owned, the Federal Government has fee simple interest for the real property asset. If the property is leased, the rights to use the asset are assigned to the Federal Government by a private entity or a non-Federal Government entity for a defined period of time in return for rental payments (FRPC 2012).

National Project: Generally large and complex projects that require professionally prepared drawings and specifications that are time phased (design and construction) and contracted by the DOL National Office.

Net Square Foot: The sum of all areas on all floors of a building assigned to, or available for assignment to, an occupant or specific use. This value is computed by physically measuring or scaling measurements from the inside faces of surfaces that form the boundaries of the designated areas. Exclude areas having less than a 3-foot clear ceiling height unless the criteria of a separate structure are met. Included should be major space use categories for assignable space (e.g., dormitories, education, recreation, etc.) that are used to accomplish the institution’s mission. Net Square foot: NASF = Sum of Areas Designated by the Major Space Use Categories (Source: http://nces.ed.gov/pubs2006/ficm/).

On Board Strength (OBS): The actual number of students on Center on a day to day basis.

Preventive Maintenance: The care and servicing by personnel for the purpose of maintaining equipment and facilities in satisfactory operating condition by providing for systematic inspection, detection, and correction of incipient failures either before they occur or before they develop into major defects (Source: Dictionary of Military and Associated Terms, US DOD 2005).

Property Type: Indicates the asset as one of the following categories of real property:

land, building, structure.

Property Use: Since the elements defined by the FRPC do not match the space use codes employed in ESCIS, a mapping procedure will be created to align the definitions.

In the report, the Federal Real Property Council (FRPC) classifications will be printed for display. The information is available through the property registration field of Engineering Support Contractor Information System (ESCIS), and the current ESCIS designations will be correlated to the FRPC designations as follows:

ESCIS FRPC

Dormitory Dormitories/Barracks Food Service Other Institutional Uses Education School Recreation Other Institutional Uses Medical/Dental Other Institutional Uses Storage Warehouse Administration Office Structure * Storage, Service, Utility

Systems, or Other Land Institutional

* Each structure will be entered manually from the ESCIS database into one of four FRPC categories listed opposite the term “structure”.

Replacement Value: The cost of replacing the existing constructed asset at today’s building standards. It is the amount required to construct an asset of similar size and in the same location at today’s construction standards. The replacement value reported must be greater than zero (FRPC 2012).

Regional Office Project: Generally smaller projects where the funds will be transferred to the region for center execution.

Structure: In accordance with the FRPC 2012 Guidance for Real Property Inventory Reporting, a structure serves to provide storage, service, utility systems and is not likely to have full utilities (heating, cooling, etc.). A structure typically is less than 400 square feet.

Sustainability: Formally known as the World Commission on Environment and Development, the Brundtland Commission's mission in the 1980s was to unite countries to pursue sustainable development. The Commission defined sustainability as the “development which meets the needs of current generations without compromising the ability of future generations to meet their own needs".

Sustainability also is defined as the creation or enhancement of environmental, economic, and social-cultural balance, as realized through business activities, individual actions, and community engagement. Sustainability addresses approaches, methods and practices that optimize the use of energy, water, and materials while reducing greenhouse gas emissions.”

Utilization: This performance measure assesses the degree to which each asset is utilized and is expressed as a percentage. It is calculated on a square footage basis, comparing the square footage used to the “design square footage” based on contract strength (Source: FRPC 2012).

Executive Summary

The facility survey for Sierra Nevada Job Corps Center was completed during April 9-18, 2014. The information presented in Volume II, Supporting Data, represents the current status of the campus.

The information includes the following:

Existing site layout Overall status of existing building and structures Space utilization by building and function compared to recommended standards Status of environmental elements of the Center’s operations Details on the site and buildings and structures based on architectural, electrical, and mechanical survey and supporting documentation Presentation of the status of historical deficiencies and compilation of deficiencies documented through this survey Supporting documentation, as presented in the appendices of the center review meeting; survey brief and student questionnaire; life safety IA/IIA transmittal;

active warranties; and Federal Real Property Council (FRPC) Measures Matrix

Section 1.0 of this volume addresses site layout and plans while Section 2.0 presents details on the buildings and structures. Section 3.0 presents historic deficiencies and their status as well as new ones identified in this survey. The appendices provide additional information as noted below:

Appendix A. Survey Brief Questionnaire Appendix B. Life Safety Deficiencies and List Appendix C. O&M Deficiencies List Appendix D. Active Warranty Report Appendix E. FRPC Performance Measures Matrix

EXECUTIVE SUMMARY

1.0 - Site Layout and Plans

SIERRA NEVADA

JOB CORPS CENTER

RENO, NEVADA

SIERRA

NEVADA JCC

10 MI5 0

2.0 - Descriptions

2.0 DESCRIPTIONS

In this section, the following information on the Center and its buildings and structures is presented in tabular format:

Building and Structures – This table indicates the building type, asset number, name, use group, gross square footage (GSF), construction year, number of floors, number of sleeping room and number of beds, construction type (noted as numerical values instead of code-specified Roman numerals), status (active or closed), and overall condition. The possible International Building Code (IBC) construction classifications include the following:

Type I and II. Those types of construction in which building elements are of noncombustible materials, except as permitted in Section 603 and elsewhere in the code.

Type III. This type of construction is where the exterior walls are of noncombustible material and the interior building elements are of any material permitted by the code.

Type IV. This type (heavy timber, HT) is where the exterior walls are of noncombustible material and the interior building elements are of solid or laminated wood without concealed spaces. Fire-retardant-treated wood framing complying with IBC section 2303.2 shall be permitted within exterior wall construction with a 2-hour rating or less.

Type V. That type of construction where structural elements, exterior walls, and interior walls are of any materials permitted by the code.

The overall building/structure condition is rated in one of three categories: good, fair, or poor.

Space Utilization by Function - This table compares the DOL recommended net square footage per enrollee and for the total function (e.g., housing, education, food service, recreation, medical/dental, administration, storage/support) to the actual values.

Net Square Footage by Building - This table compares the DOL recommended net square footage for the buildings with the function (e.g., housing, education, food service, recreation, medical/dental, storage/support) to the actual values and presents a percentage difference in the two values. In some instances, a recommended value is not available for sub-elements of a function; therefore, the recommended value is shown as “0”.

Environmental Management Report – This table summarizes regulatory related solid and hazardous waste information in accordance with the Resource Conservation and Recovery Act (RCRA) and the presence or absence of hazardous material storage facilities in accordance with Emergency Planning and Community Right-to-Know Act of

1986 (EPCRA). An inventory of petroleum storage tanks is noted as well as asbestos and polychlorinated biphenyls (PCBs) in accordance with the Clean Water Act (CWA) and Toxic Substance Control Act (TSCA), respectively. In addition, this report statuses air quality as required under the Clean Air Act (CAA).Any radon testing of buildings also is documented.

Site Descriptions – Tabular information is documented for the site. Among the data presented are the topography; total number of buildings and structures; roads, parking and sidewalks; fencing; site utilities; storage tanks; accessibility; historic preservation;

natural hazards; and sustainability. The overall condition of the site is rated in one of three categories: good, fair, or poor.

Building Descriptions – Tabular information, as well as photographs and floor plan drawings, are provided for each building or structure, as appropriate, in the following categories: real estate; accessibility; building envelope; interior finishes; vertical circulation; heating, ventilation and air conditioning (HVAC); plumbing; fire protection;

electrical services; fire alarms; carbon monoxide detection; communication; and building metering. The overall condition of the building and its five key subsystems (structure, exterior, interior, mechanical, and electrical) are rated in one of three categories: good, fair, or poor. If applicable, recommendations for renovation or demolition are provided.

BUILDINGS AND STRUCTURES

00907 SIERRA NEVADA 12/04/2014

1Page: of Date:

0001 - ADMINISTRATION

0002 - EDUCATION 1 (ED-1)

0003 - EDUCATION 2 (ED-2)

0004 - HEALTH SERVICES/WELLNESS

0005 - STUDENT SERVICES & SECURITY

0006 - VOCATION (A)

0007 - VOCATION (B)

0008 - VOCATION (C)

0010 - CULINARY ARTS/HOSPITALITY

0011 - DONNER HALL DORMITORY

0015 - WASHOE HALL - CO-ED DORM

0016 - SECURITY VOCATION

0018 - LASSEN HALL/ FEMALE

DORMITORY

0019 - COMSTOCK HALL-MEN'S DORM

0020 - FREMONT HALL-MEN'S DORM

0021 - CARSON HALL-MEN'S DORM

0022 - CAFETERIA

0023 - CENTER DUTY OFFICER

0025 - RECREATION

0026 - GYMNASIUM

0029 - SUPPORT SERVICES BUILDING

0030B- VOCATIONAL STORAGE

0031 - THEATRE

0019A - GAZEBO (35Ft x 20Ft) 0022A - GAZEBO (10Ft x 10Ft) 0022B - GAZEBO (10Ft x 10Ft) 0022C - GAZEBO (24Ft x 10Ft) 0026A - IRRIGATION SHED (10Ft x 6Ft) 0026B - RECREATION STORAGE #1 (8Ft x 6Ft)

0026C - RECREATION STORAGE #2

(10Ft x 8Ft) 0027 - VACUUM MAINTENANCE (16Ft x 16Ft) 0027A - SECURITY STORAGE (14Ft x 8Ft) 0028B - GAZEBO (20Ft x 10Ft) 0030C- PLASTERING STORAGE (14Ft x 14Ft) 0030D- CTST STORAGE (82Ft x 19Ft) 0030E - WELDING STORAGE (8Ft x 8Ft) 0030F - CEMENT STORAGE (10Ft x 8Ft) 0039 - VALVE HOUSE (14Ft x 11Ft) 0040A - GAZEBO (10Ft x 10Ft) 0040B - GAZEBO (24Ft x 8Ft) 0040C - GAZEBO (16Ft x 8Ft) 0042 - TRELLIS (15Ft x 10Ft) 0043 - RESIDENTIAL STORAGE (7Ft x 7Ft)

Name GSF

8,623 20,942 11,035 5,770

16,472 8,171 8,564

19,327 11,000 21,920 21,920 1,710

16,920

16,920 16,920 16,920 20,130

3,560 15,150 10,600 15,600 2,190 5,090

1,558

Active Active Active Active Active Active Active Active Active Active Active Active Active

Active Active Active

Demolition Approved

Active Active Active Active Active Active Active Active Active Active Active Active

Active

Active

Active Active Active

Active Active Active Active Active Active Active Active Active

StatusType

Building Building Building Building Building Building Building Building Building Building Building Building Building

Building Building Building Building

Building Building Building Building Building Building Structure Structure Structure Structure Structure Structure

Structure

Structure

Structure Structure Structure

Structure Structure Structure Structure Structure Structure Structure Structure Structure

Use Group Built Flrs Const

Business Business Business Business Business Business Business Business Business Residential Residential Business Residential

Residential Residential Residential Assembly

Business Assembly Assembly Factory/Ind.

Business Assembly Assembly Assembly Assembly Assembly Utility/Misc.

Storage

Storage

Storage

Business Assembly Storage

Storage Storage Business Utility/Misc.

Assembly Assembly Assembly Assembly Storage

Good Good Good Good Good Good Good Good Fair

Good Good Good Good

Good Good Good Fair

Good Good Good Good Good Fair

Good Good Good Good Good Good

Good

Good

Good Good Good

Good Good Good Good Good Good Good Good Good

ConditionAsset Number

0090708025 0090708026 0090708027 0090708007 0090708028 0090708029 0090708030 0090708031 0090700006 0090700007 0090700008 0090700035 0090700009

0090700010 0090700011 0090700012 0090700013

0090700014 0090708032 0090700015 0090708005 0090700037 0090700019 0090708019 0090700065 0090700068 0090708012 0090700056 0090708047

0090708048

0090700041

0090708049 0090708013 0090700043

0090700044 0090708045 0090708046 0090700033 0090708014 0090708015 0090708016 0090708021 0090708022

BUILDINGS AND STRUCTURES

00907 SIERRA NEVADA 12/04/2014

2Page: of Date:

23 295,454

20 4,576

43 300,030

Buildings

Structures

Total

GSF

GSF

GSF

Summary

12/04/2014

Space Utilization By Function 00907 Sierra Nevada Page: 1 of Date:

HOUSING

EDUCATION

FOOD SERVICE

SUGGESTED

NSF/

ENROLLEE

SUGGESTED

TOTAL

NSF

ACTUAL

TOTAL

NSF

TYPE OF SPACE

SUB TOTAL

SUB TOTAL

SUB TOTAL

Resident Men Resident Women Total Residents

Residents 545 Non Residents 25

570Total Students

(545)

(570)

(570)

DIFFERENCE

58,860

44,400

10,260

79,945

70,349

13,571

Lounge Other Shower/Toilet Sleeping excl. SPD( rooms; beds) Storage

Academic (570) Non-Academic

30 -- ACT (Off-Ctr) 40 -- Auto Repair Tech/Helper + 90 -- Business Office Technologies 40 -- Carpentry + 20 -- Cement Masonry + 40 -- Culinary Arts + 24 -- Electrical + 24 -- Facilities Maint. and Const. + 90 -- Health Occupations + 30 -- Hotel Management 24 -- Maintenance Engineer + 20 -- Painting + 20 -- Plastering + 24 -- Plumbing + 20 -- Security Officer 24 -- Welding +

Vocational Theory (390)

Dining (2 Servings) Food Preparation Food Storage

4,590 6,150

11,253 54,177

3,775

8,918 12,640

2,480 4,100 2,907 3,260 5,725 2,546 3,054 3,835 1,798 2,539 2,184 3,260 2,574

4,421

3,245

5,051 4,728 3,792

5,450 4,360 6,540

39,240 3,270

5,700 5,700

3,000 3,600 3,000 1,500 2,400 1,200 1,800 3,600 1,200 1,200 1,500 1,500 1,200

1,800

3,900

4,560 3,420 2,280

-860 1,790 4,713

14,937

3,218 6,940

-520 -93

1,760 3,325 1,346 1,254

1,339

1,760 1,374

2,621

-655

1,308 1,512

Vocations

21,085

25,949

3,311

Page: 2 of Date:

RECREATION

MEDICAL/DENTAL

ADMINISTRATION

STORAGE/SUPPORT

VACANT

SUGGESTED

NSF/

ENROLLEE

SUGGESTED

TOTAL

NSF

ACTUAL

TOTAL

NSF

TYPE OF SPACE

SUB TOTAL

SUB TOTAL

SUB TOTAL

SUB TOTAL

SUB TOTAL

TOTAL 293.14 167,090 216,967

(570)

(570)

(570)

(570)

(0)

DIFFERENCE

27,625

3,145

11,400

23,289

4,150

8,405

14,098

3,160

Aerobics/Exercise Arts & Crafts Computer Lab Concession Stand/Restroom Gymnasium Lounges Miscellaneous Recreation Multipurpose Room Recreation Office Recreation Storage Theater Weight Room

Medical/Dental

Administration

Operations & Maintenance Warehouse

Under Renovation - Education Under Renovation - Housing Under Renovation - Recreation Vacant

5.52

7,277

1,267 3,022

5,567

4,150

8,405

4,545 9,553

1,493

3,145

4,560 6,840

7,277

1,267 3,022

5,567

1,005

-2,995

-15 2,713

1,493

RESIDENT

NON-RESIDENT

(545)

(25) 15

50 27,250

-4,336

1,005

-2,995

2,698

3,160

49,877

Page: 3 of Date:

SUGGESTED

NSF/

ENROLLEE

SUGGESTED

TOTAL

NSF

ACTUAL

TOTAL

NSF

TYPE OF SPACE DIFFERENCE

295,454

0.73

TOTAL GSF

NET TO GROSS RATIO

Net Square Footage By Building Date: 12/04/2014 Page: 1

Center: SIERRA NEVADA (00907) of 5

HOUSING

Sleeping excl. SPD

Lounge

Storage

Shower/Toilet

Other

Function Suggested

NSF

7,806 7,799

11,092 10,875

8,896 7,709

1,162

1,388

3,129 1,463

1,427 3,032 1,472

1,215

1,214 1,227

0021 - CARSON HALL-MEN'S DORM

0020 - FREMONT HALL-MEN'S DORM

0015 - WASHOE HALL - CO-ED DORM

0011 - DONNER HALL DORMITORY

0019 - COMSTOCK HALL-MEN'S DORM

0018 - LASSEN HALL/ FEMALE DORMITORY

0011 - DONNER HALL DORMITORY

0015 - WASHOE HALL - CO-ED DORM

0018 - LASSEN HALL/ FEMALE DORMITORY

0019 - COMSTOCK HALL-MEN'S DORM

0021 - CARSON HALL-MEN'S DORM

0020 - FREMONT HALL-MEN'S DORM

0015 - WASHOE HALL - CO-ED DORM

0020 - FREMONT HALL-MEN'S DORM

0018 - LASSEN HALL/ FEMALE DORMITORY

0021 - CARSON HALL-MEN'S DORM

0019 - COMSTOCK HALL-MEN'S DORM

0011 - DONNER HALL DORMITORY

0023 - CENTER DUTY OFFICER

0015 - WASHOE HALL - CO-ED DORM

0021 - CARSON HALL-MEN'S DORM

0019 - COMSTOCK HALL-MEN'S DORM

0018 - LASSEN HALL/ FEMALE DORMITORY

0011 - DONNER HALL DORMITORY

0020 - FREMONT HALL-MEN'S DORM

0018 - LASSEN HALL/ FEMALE DORMITORY

0015 - WASHOE HALL - CO-ED DORM

0021 - CARSON HALL-MEN'S DORM

0019 - COMSTOCK HALL-MEN'S DORM

0011 - DONNER HALL DORMITORY

0020 - FREMONT HALL-MEN'S DORM

Bldg Name Actual NSF Difference

54,177

4,590

3,775

11,253

6,150

Sub Total: 79,945

39,240

5,450

3,270

6,540

4,360

58,860

14,937

-860

4,713

1,790

( 545

21,085 rooms; beds rooms; beds rooms; beds rooms; beds rooms; beds rooms; beds

Page: 2

Center: SIERRA NEVADA (00907) of 5

EDUCATION

Academic

Vocational Theory (390)

Carpentry

Cement Masonry

Electrical

Plumbing

Health Occupations

Culinary Arts

Welding

Painting

Plastering

Hotel Management

Facilities Maint. and Const.

Non-Academic

Function Suggested

NSF

2,293

1,650

1,677 1,097

1,986

2,907

3,260

2,546

2,574

3,835

5,725

4,421

2,184

3,260

1,798

2,537

8,361 2,449

1,107

0002 - EDUCATION 1 (ED-1)

0002 - EDUCATION 1 (ED-1)

0002 - EDUCATION 1 (ED-1)

0002 - EDUCATION 1 (ED-1)

0002 - EDUCATION 1 (ED-1)

0002 - EDUCATION 1 (ED-1)

0002 - EDUCATION 1 (ED-1)

0002 - EDUCATION 1 (ED-1)

0008 - VOCATION (C)

0007 - VOCATION (B)

0006 - VOCATION (A)

0008 - VOCATION (C)

0006 - VOCATION (A)

0008 - VOCATION (C)

0007 - VOCATION (B)

0003 - EDUCATION 2 (ED-2)

0010 - CULINARY ARTS/HOSPITALITY

0007 - VOCATION (B)

0008 - VOCATION (C)

0006 - VOCATION (A)

0010 - CULINARY ARTS/HOSPITALITY

0008 - VOCATION (C)

0030B- VOCATIONAL STORAGE

0005 - STUDENT SERVICES & SECURITY

0002 - EDUCATION 1 (ED-1)

0002 - EDUCATION 1 (ED-1)

0002 - EDUCATION 1 (ED-1)

Bldg Name Actual NSF Difference

8,918

3,245

2,907

3,260

2,546

2,574

3,835

5,725

4,421

2,184

3,260

1,798

3,054

12,640

5,700

3,900

3,000

1,500

1,200

1,200

3,600

2,400

1,800

1,500

1,500

1,200

1,800

5,700

3,218

-655

-93

1,760

1,346

1,374

3,325

2,621

1,760

1,254

6,940

( 570 )

Page: 3

Center: SIERRA NEVADA (00907) of 5

EDUCATION

FOOD SERVICE

Maintenance Engineer

Security Officer

Business Office Technologies

Auto Repair Tech/Helper

Dining (2 Servings)

Food Preparation

Food Storage

Function Suggested

NSF

2,539

4,100

2,480

5,051

4,728

3,792

0008 - VOCATION (C)

0016 - SECURITY VOCATION

0003 - EDUCATION 2 (ED-2)

0008 - VOCATION (C)

0022 - CAFETERIA

0022 - CAFETERIA

0022 - CAFETERIA

Bldg Name Actual NSF Difference

2,539

4,100

2,480

5,051

4,728

3,792

Sub Total:

Sub Total:

70,349

13,571

1,200

3,600

3,000

4,560

3,420

2,280

44,400

10,260

1,339

-520

1,308

1,512

( 570

25,949

3,311

Page: 4

Center: SIERRA NEVADA (00907) of 5

RECREATION

MEDICAL/DENTAL

Multipurpose Room

Arts & Crafts

Gymnasium

Weight Room

Theater

Lounges

Miscellaneous Recreation

Aerobics/Exercise

Concession Stand/Restroom

Computer Lab

Recreation Storage

Recreation Office

Medical/Dental

Function Suggested

NSF

3,022

7,277

1,381 4,186

1,267

4,150

0025 - RECREATION

0025 - RECREATION

0026 - GYMNASIUM

0025 - RECREATION

0025 - RECREATION

0031 - THEATRE

0025 - RECREATION

0025 - RECREATION

0025 - RECREATION

0025 - RECREATION

0026 - GYMNASIUM

0025 - RECREATION

0026 - GYMNASIUM

0025 - RECREATION

0026 - GYMNASIUM

0025 - RECREATION

0004 - HEALTH SERVICES/WELLNESS

Bldg Name Actual NSF Difference

3,022

7,277

5,567

1,267

4,150

Sub Total:

Sub Total:

23,289

4,150

3,145

27,625

3,145

1,005

-4,336

1,005

Page: 5

Center: SIERRA NEVADA (00907) of 5

ADMINISTRATION

STORAGE/SUPPORT

VACANT

Administration

Warehouse

Operations & Maintenance

Vacant

Under Renovation - Housing

Under Renovation - Education

Under Renovation - Recreation

Function Suggested

NSF

1,390

5,386 1,348

9,553

4,545

1,493

0005 - STUDENT SERVICES & SECURITY

0016 - SECURITY VOCATION

0001 - ADMINISTRATION

0023 - CENTER DUTY OFFICER

0029 - SUPPORT SERVICES BUILDING

0029 - SUPPORT SERVICES BUILDING

0005 - STUDENT SERVICES & SECURITY

0016 - SECURITY VOCATION

0023 - CENTER DUTY OFFICER

0021 - CARSON HALL-MEN'S DORM

0030B- VOCATIONAL STORAGE

0026 - GYMNASIUM

Bldg Name Actual NSF Difference

8,405

9,553

4,545

1,493

Sub Total:

Sub Total:

Sub Total:

8,405

14,098

3,160

11,400

6,840

4,560

11,400

11,400

-2,995

2,713

-15

1,493

-2,995

2,698

3,160

Environmental Management Report Center: SIERRA NEVADA (00907)

Page: 1 Date: 12/04/2014 of 2

SOLID & HAZARDOUS WASTE MANAGEMENT (RCRA)

Commercial Waste Service

HAZARDOUS MATERIALS STORAGE (EPCRA)

Yes Buildings 22, 30, 33, 34, 35, 35a, 36, 38

Propane gas (15 gal.), gasoline (10 gal.), kerosene (3 gal.), organic solvent (24 gal.), oil-based paint ( 20 gal.)

Yes

PETROLEUM UNDERGROUND STORAGE TANKS (RCRA)

Compliance0

PETROLEUM ABOVEGROUND STORAGE TANKS (CWA)

ASBESTOS AND PCB MANAGEMENT (TSCA)

Solid Waste Disposal :

Hazardous Waste Generator :

Hazardous Waste ID :

Generator Classification :

Hazadous Materials Storage :

Hazardous Materials ID :

HazMat Storage Area :

HazMat Spill Response Plan :

Number of Regulated USTs :

Number of Un-regulated USTs :

Local Hazardous Use Permit :

LEPC Notification :

EPA Generator ID Number :

Hazardous Waste Disposal :

RCRA Compliance

Building 10

Building 11

Building 15

Building 22

Building 26

Building 31

2,000

2,000

2,000

5,000

2,000

1,200

Petroleum - Heating Oil

Petroleum - Heating Oil

Petroleum - Heating Oil

Petroleum - Heating Oil

Petroleum - Heating Oil

Petroleum - Heating Oil

ID LocationFuel Type Capacity

Number of ASTs :

Asbestos Survey Date :

Asbestos Type :

Asbestos Coordinator :

Coordinator Training Date:

Custodial/Maintenance Training :

AHERA Regulated :

Management Plan Approval :

PCB Transformer Testing :

PCB Transformers :

PCB-Contaminated Transformers :

Transformers Labelled :

Reno Disposal, Inc.

Yes Lead/acid batteries (2/month), waste oil (15 gals/month)

Conditionally Exempt Small Quantity Generator

NVD 982443293

Municipal Hazardous Waste Disposal Service

University of Nevada-Reno HAZ-MAT Office

Yes Yes

Overfill Leak Corrosion

SPCC Plan Required : SPCC Plan Completed :

No N/A

02/10/1991 Friable/Non-Friable Randy Klatt 03/01/1999 Yes No N/A Yes Yes

No

No

No

Yes

No

No

No

No

No

Yes

No

No

No

No

No

Yes

No

No

ID Fuel Type Capacity Location Overfill

Prevention Secondary ContainmentTank Status

Active

Abandoned

Abandoned

Active

Abandoned

Abandoned

Tank Status Prevention/Detection

Environmental Management Report

Page: 2 Date: 12/04/2014 of 2

AIR POLLUTION CONTROL (CAA)

N/A None

Non-AttainmentRegional Air Quality :

Permitted Air Pollution Source :

Source Description :

CO, PM-10

Asbestos-Containing Materials Inventory

Date: 12/04/2014Center : Sierra Nevada (00907) Page: 1 of 3

Heating Heating Heating Heating Heating Heating Heating

Floor Finishes Water Plumbing Floor Finishes Floor Finishes

Floor Finishes Floor Finishes

Floor Finishes Floor Finishes Heating Heating Floor Finishes

Water Plumbing Water Plumbing

Bldg System

Bldg System

Bldg System

Bldg System

Bldg System

Pipe fitting insulation Pipe insulation Boiler insulation Pipe fitting insulation Pipe insulation Pipe fitting insulation Pipe insulation, pre-cast

9x9 floor tile, green Pipe fitting insulation 9x9 floor tile (covered) 9x9 floor tile, blue

9x9 floor tile, tan Mastic beneath 9x9 tile

Mastic beneath 9x9 tile 9x9 floor tile, tan Pipe fitting insulation Pipe fitting insulation 9x9 floor tile (covered)

Pipe fitting insulation Pipe fitting insuation

Category Description

Category Description

Category Description

Category Description

Category Description

Ea.

Lin. Ft.

Sq. Ft.

Ea.

Lin. Ft.

Ea.

Lin. Ft.

Sq. Ft.

Ea.

Sq. Ft.

Sq. Ft.

Sq. Ft.

Sq. Ft.

Sq. Ft.

Sq. Ft.

Ea.

Ea.

Sq. Ft.

Ea.

Ea.

Location

Location

Location

Location

Location

Unit

Unit

Unit

Unit

Unit

Quantity

Quantity

Quantity

Quantity

Quantity

Classrooms Classrooms Boiler room Interior hallway Boiler room Boiler room Interior hallway

2nd flr, storage Laundry room 2nd flr, dorm area Basement hallway

Throughout Throughout

Throughout Hallway 2nd flr, storage Room 217 Throughout

Laundry room Storage closet

18000 18000

Building :

Building :

Building :

Building :

Building :

0010 - CULINARY ARTS/HOSPITALITY

0011 - DONNER HALL DORMITORY

0015 - WASHOE HALL - CO-ED DORM

0018 - LASSEN HALL/ FEMALE DORMITORY

0019 - COMSTOCK HALL-MEN'S DORM

Page: 2 of 3

Floor Finishes Floor Finishes

Heating Heating Heating Roof Repair/Replacement

Roof Repair/Replacement Heating

Heating Heating Heating Heating Heating Heating Heating Heating Plumbing (Bldg) Exterior Walls

Bldg System

Bldg System

Bldg System

Bldg System

9x9 floor tile, brown Mastic beneath 9x9 tile

Boiler exhaust insulation Pipe fitting insulation Boiler insulation Asbestos cement board

Built-up roofing Pipe insulation, pre-cast

Pipe fitting insulation Boiler insulation Pipe insulation, pre-cast Pipe insulation, air-cell Pipe insulation Pipe fitting insulation Pipe insulation, air-cell Boiler exhaust insulation Pipe Fitting Insulation Asbestos cement board

Category Description

Category Description

Category Description

Category Description

Sq. Ft.

Sq. Ft.

Sq. Ft.

Ea.

Sq. Ft.

Sq. Ft.

Sq. Ft.

Lin. Ft.

Ea.

Sq. Ft.

Lin. Ft.

Lin. Ft.

Lin. Ft.

Ea.

Lin. Ft.

Sq. Ft.

Ea.

Sq. Ft.

Location

Location

Location

Location

Unit

Unit

Unit

Unit

Quantity

Quantity

Quantity

Quantity

Rooms 221 thru 228 Rooms 221 thru 228

Boiler room Boiler room Boiler room Loading dock

Throughout Tunnel pipe chase

Boiler room Boiler room Boiler room Gymnasium Locker rooms Locker rooms Boiler room Boiler room Court Area Above windows

Building :

Building :

Building :

Building :

0020 - FREMONT HALL-MEN'S DORM

0022 - CAFETERIA

0023 - CENTER DUTY OFFICER

0026 - GYMNASIUM

Page: 3 of 3

Heating Heating Heating Heating Roof Repair/Replacement Heating Heating Heating Heating Heating

Bldg System Pipe fitting insulation Pipe insulation, air-cell Boiler insulation Pipe fitting insulation Roof flashing Pipe insulation, air-cell Pipe insulation, air-cell Pipe insulation, air-cell Pipe fitting insulation Pipe insulation, pre-cast

Category Description Ea.

Lin. Ft.

Sq. Ft.

Ea.

Lin. Ft.

Lin. Ft.

Lin. Ft.

Lin. Ft.

Ea.

Lin. Ft.

Location Unit Quantity Projection room Projection room Boiler room Boiler room Throughout Boiler room Stage area Bathrooms Bathrooms Boiler room

Building : 0031 - THEATRE

Radon

Page: 1 of 2

0001 - ADMINISTRATION

0002 - EDUCATION 1 (ED-1)

0003 - EDUCATION 2 (ED-2)

0004 - HEALTH SERVICES/WELLNESS

0005 - STUDENT SERVICES & SECURITY

0006 - VOCATION (A)

0007 - VOCATION (B)

0008 - VOCATION (C)

0010 - CULINARY ARTS/HOSPITALITY

0011 - DONNER HALL DORMITORY

0015 - WASHOE HALL - CO-ED DORM

0016 - SECURITY VOCATION

0018 - LASSEN HALL/ FEMALE DORMITORY

0019 - COMSTOCK HALL-MEN'S DORM

0020 - FREMONT HALL-MEN'S DORM

0021 - CARSON HALL-MEN'S DORM

0022 - CAFETERIA

0023 - CENTER DUTY OFFICER

0025 - RECREATION

0026 - GYMNASIUM

0029 - SUPPORT SERVICES BUILDING

0030B- VOCATIONAL STORAGE

0031 - THEATRE

Bldg Name

06/11/1990

08/11/1992

06/11/1990

06/11/1990

06/11/1990

06/11/1990

08/11/1992

06/11/1990

06/11/1990

06/11/1990

08/11/1992

06/11/1990

08/11/1992

Test Date

No

No

No

No

No

No

No

No

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

No

Yes

No

Yes

Yes

Radon Testing

< 4 pCi

> 20 pCi

< 4 pCi

< 4 pCi

< 4 pCi

4 - 20 pCi

< 4 pCi

< 4 pCi

< 4 pCi

< 4 pCi

< 4 pCi

< 4 pCi

< 4 pCi

Test Result

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

No

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Mitigation Mitigation Date

Radon

Page: 2 of 2

RADON EXPLANATORY NOTES

The US Environmental Protection Agency (EPA) has established a radon action level of 4.0 picoCuries per liter (pCi/L). Occupied buildings with radon concentrations less than 4.0 pCi/L do not require radon mitigation; un-occupied buildings, or those buildings which are occupied only infrequently for brief periods of time, also do not require radon mitigation. Occupied buildings with radon concentrations greater than

4.0 pCi/L require radon mitigation and verification of radon reductions as soon as possible, with priority given to dormitories and student recreation buildings. Occupied buildings with radon concentrations greater than 20.0 pCi/L should be considered significant radon exposure hazards, and priority for mitigation should be given to buildings with these highly elevated radon concentrations.

Radon mitigation techniques include: (1) adjustment of the building HVAC system to create a positive pressure within the building; (2) sealing of foundation wall cracks, penetrations, or other openings;

(3) sealing crawlspace openings and sump pits; (4) installing an active subslab depressurization (ASD) system.

Site Description

Mountains in the background

Page: 1 Date: 12/04/2014 of 4

Comments:

Paving Type for Roads & Parking

Generally, the roads and sidewalks are in good condition. There are areas where minor repairs are needed; the parking area between Buildings 1 and 15 is partially deteriorated.

Paving Type for Sidewalks

Asphalt Concrete

Comments:

Topography Buildings and Structures

Center is not fully enclosed by fencing. There is a chain link fence and masonry wall at the perimeter to enclose most of the center property.

ROADS, PARKING & SIDEWALKS

Water Source Water Authority Service Meter On-Site Treatment Plant

1. Water System

Treatment Type Storage Type Storage Capacity(Gallons)

NoMasterTruckee Meadows Water AuthorityPublic Water Authority

None 0None

There are numerous water meters spread throughout the campus. Meters serve multiple buildings and irrigation lines.

Comments:

Comments:

Fire Hydrants On-Site Water Supply Storage Capacity

(Gallons) Pressure Source FD Response Time (Minutes)

Yes 0 5None Municipal

A fire station is less than one mile away with about 3 to 5 minutes response time.

SITE FEATURES

UTILITIES

2. Fire Protection System

Buildings Structures23 20Flat with gentle slopes

Surrounding

Outdoor Recreation

Airport, Housing, School

Basketball, Soccer Fields, Soft/Baseball None

Most of the site

Part of the perimeter

Chain Link

CMU

Location Type

Maintenance Responsibility System Capacity Adequate System Condition

Center Center Yes Good

Separate Loop

No

Ownership Maintenance Responsibility System Capacity Adequate System Condition

Center Center Yes Good

Ownership

Roads & Parking Adequate Roads & Parking Condition Sidewalks Adequate Sidewalk Condition Yes Good Yes Good

Fencing

Other Features

Page: 2 Date: 12/04/2014 of 4

Sewage Treatment Flow

Center

Publicly Owned Treatment Works

Center

Gravity

Maintenance ResponsibilityOwnership

Comments: Natural gas is metered for each building. Fuel oil is provided by Reno Fuel Co. and fuel oil tanks are dedicated to individual buildings.

Sierra Pacific Power Co.

Comments:

Electric Company PCB Trans.

Transformer Mounting Transformer Ownership

Systems Ownership Maintenance Responsibility

Nevada Energy

Electrical service is brought to the center from three locations from power poles along Mt. Bismark Street and Echo Avenue. The primary metering is located at the utility pole on Echo Avenue and secondary meters are installed in the majority of buildings on center. Most existing building services are overhead with pole-mounted and/or platform-mounted transformers while new buildings have underground services via pad-mounted transformers. Vocational Buildings 6, 7 and 8 secondary services are 480/277V, 3-phase, 4 wire with step-down transformers providing 120/208V, 3-phase, 4 wire system. Dormitory, Buildings 11, 15, 18, 19, 20 and 21 are each provided with a 1.5 kW generator to back-up the emergency lighting system in the buildings. The Cafeteria Building 22 has a 230 kVA diesel generator with automatic transfer switch (ATS) located outside in the back of the building.

Pole,Pad and Platform Center

Center Center

No

4.16/2.4 kV, 3-Ph, 4 W

480/277V and 120/208V, 3-Ph, 4 WOverhead & Underground

Overhead & UndergroundPrimary Service

Secondary Service

Distribution Characteristics

3. Sanitary Sewer System/ Sewage Treatment Plant

5. Fuel Distribution System

Number of Deficiencies = 4

System Capacity Adequate System Condition

Yes Good

4. Storm Water System Number of Deficiencies = 1

Drain Type On-Site Storm Water Management

Underground N/A

Ownership Maintenance Responsibility System Capacity Adequate System Condition

Center Yes GoodCenter

Gas Company Metering

Individual

Ownership Maintenance Responsibility System Capacity Adequate System Condition

Center Center Yes Good

7. Electrical (Service)

Transformer Maint Resp

Utility

System Capacity Adequate System Condition

Yes Good

Generator

Diesel

ATS MTS

Yes Yes

6. Central Plant: None

Metering Master-Smart Meter

Page: 3 Date: 12/04/2014 of 4

Comments:

Telephone Company

On-site Line Owner

Telephone/data service is brought to the center by AT&T via five T1 lines and terminates in the computer room in Security Vocation Building 16. From this location, digital voice over IP (VoIP) and data/communication networks are distributed throughout the center. The networks are provided and maintained by Job Corps Data Center. The fire alarm systems in buildings throughout the center are stand alone; however they are monitored via telephone line by the center's fire alarm system contractor. There is no electronic security system on site but some buildings on the center, especially the dormitories, are provided with door alarms and motion sensors to protect the buildings from unauthorized ingress/egress. Cable television is provided in all dormitories.

AT&T

Maint. Responsibility

Center Center

Door Alarms, Motion Sensors, Keypads

01/01/1987

01/01/1986

01/01/1986

01/01/1986

01/01/1987

01/01/1986

Center

Center

Center

Center

Center

Center

Active

Abandoned

Abandoned

Active

Abandoned

Abandoned

Underground, Non-regulated

Underground, Non-regulated

Underground, Non-regulated

Underground, Non-regulated

Underground, Non-regulated

Underground, Non-regulated

Building 10

Building 11

Building 15

Building 22

Building 26

Building 31

No

No

No

Yes

No

No

Petroleum - Heating Oil

Petroleum - Heating Oil

Petroleum - Heating Oil

Petroleum - Heating Oil

Petroleum - Heating Oil

Petroleum - Heating Oil

STORAGE TANKS

TypeStatus Location Owner Fuel Type Capacity (Gallons) Install DateID

Reg.

9. Electrical (Communication/Alarm/Security)

Heating

Heating

Heating

Heating

Heating

Heating

Purpose

Yes

Stand-Alone

VOIP

System Capacity Adequate System Condition

GoodYes

8. Electrical (Site Lighting)

Roadways Parking Walkways Building Outdoor Sports

Mounting

Control

Pole Pole Bollard Building Sport Light

Photocell Photocell, Time Clock, Switch

Time Clock, Photocell Photocell Switch

System Ownership Maintenance Responsibility System Capacity Adequate System Condition

Utility, Center Center Yes Good

Comments: The site lighting system is a combination of building-mounted fixtures, pole-mounted fixtures at parking areas, post-mounted fixtures along walkways and sport lights at the ball field.