Sheet1
| ACRx IDIQ Questions and Answers | ||
| Line # | Questions | Answers |
| 1 | Will this project have prevailing wage requirements? I don't see any mention of Davis-Bacon in the RFP, but want to be sure to provide the most accurate proposal possible. | No, the FBI determined that this requirement does not fall within the Davis-Bacon. |
| 2 | The mention of drawings to be supplied of Antennas. Can these drawings be made available to assist in determining the required antenna mounts and accurate costs, based on the TIA standards. | Final CDs and initial site surveys of the installation with suggested antenna mounts, ice shields, and antenna drawings have been attached. Information in the site surveys may have been changed prior to the release of the task order. |
| 3 | The "Testing" paragraph discusses testing for fiber with OTDR. Will any other lines require testing? | Individual fiber strands may be tested with an OTDR, LMR400 lines may be tested for voltage, nominally -48 VDC. |
| 4 | It is our understanding that cable support facilities and entry ports are available and sufficient to support the new cabling installed. Please confirm. | The Government is requiring the contractor to confirm this prior to install. |
| 5 | Can site survey reports be provided to assist in this RFP response? | Please see Question 2. |
| 6 | Are Ice Shields to be considered GFE? | The contractor shall supply and install the ice shields. |
| 7 | It is our understanding that the government will be responsible for obtaining permits within the relevant jurisdictions. Please confirm. | The Government will be responsible for obtaining permits within the relevant jurisdictions. |
| 8 | It is our understanding that all towers have passed a structural analysis for the proposed new loading and no structural improvements are required as part of the pricing. Please confirm. | The towers have passed structural analysis for the proposed new loading and no structural improvements are required. The contractor may contact the site manager to verify if they choose. |
| 9 | Does this effort have an incumbent and if so, if you could please provide the incumbent vendor and contract number. | This effort does not have an incumbent. |