DF_013984.02_-_NGIP_PH_2_Monument_Sign_Exhibit_20250311.pdf

PDF 3 MB Posted

Attached to
North Greenwood Industrial Park Phase Two Site Development and Design/Build Speculative Building
Solicitation number
2025-GEN-002
Issued by
Greenwood County, South Carolina

About this file

This document is a detailed landscape and electrical design exhibit for the North Greenwood Industrial Park Phase 2 project in Greenwood County, South Carolina. The exhibit includes comprehensive plans for a monument sign installation, featuring specific landscape and irrigation design specifications, plant schedules, and electrical infrastructure details. The plant schedule includes 3 October Glory Maple trees, 3 Tuscarora Crape Myrtle trees, 5 Encore Azaleas, 12 Crimson Pygmy Barberry shrubs, 14 Winter Gem Boxwood shrubs, 6 Ruby Loropetalum shrubs, 51 Happy Returns Daylilies, and 23 Lily Turf perennials, along with detailed planting and seeding instructions.

The electrical design includes an electrical equipment rack with specifications for power supply, lighting controls, and irrigation controller installation. The irrigation system will be controlled by a RainBird ESP-LXME 12-station outdoor controller with a rain sensor, using commercial-grade RainBird components. The design specifies Schedule 40 PVC pipe for mainlines and laterals, with separate zones for turf and bed areas. The project includes provisions for Duke Energy utility service, underground conduits, and specific installation details for lighting bases and electrical equipment. The document emphasizes compliance with local, state, and federal requirements, and includes warranty provisions for landscaping and turf establishment.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NPDESNPDESNPDESNPDES

LIMITS OF IRRIGATION

CONTOURED BED EDGE

SEED DISTURBED AREAS

SEE SHEET C-XXX

SEED DISTURBED AREAS

3 - LAGI

20 - HEMH

3 - LORC

1 - AZAE

6 - BERT

7 - BUXS

11 - LIRM

3 - AZAE

10 - HEMH6 - BERT

7 - BUXS

12 - LIRM

1 - AZAE

3 - LORC

21 - HEMH

3 - ACER

CONTOURED BED EDGE

M

APPROXIMATE LOCATION

OF METER AND BACKFLOW

PREVENTER

MULCH

SYMBOL DESCRIPTION QTY DETAIL

Mulch 14.06 cyM-101

MULCH SCHEDULE

TREES CODE QTY BOTANICAL NAME / COMMON NAME CONT./CAL. SIZE SPACING

ACER 3 Acer rubrum `October Glory` TM / October Glory Maple B & B 2.5" As Shown

LAGI 3 Lagerstroemia indica x faurei `Tuscarora` / Tuscarora Crape Myrtle Multi-Stem

B & B 1.5" As Shown

SHRUBS CODE QTY BOTANICAL NAME / COMMON NAME CONT. SIZE SPACING

AZAE 5 Azalea Encore `Rouge` / Encore Azalea 5 gal --- As Shown

BERT 12 Berberis thunbergii `Nana` / Crimson Pygmy Barberry 3 gal --- As Shown

BUXS 14 Buxus sinica insularis 'Winter Gem' / Winter Gem Boxwood 3 gal --- As Shown

LORC 6 Loropetalum chinense 'Ruby' / Ruby Loropetalum 7 gal --- As Shown

PERENNIALS CODE QTY BOTANICAL NAME / COMMON NAME CONT. SIZE SPACING

HEMH 51 Hemerocallis x 'Happy Returns' / Happy Returns Daylily 1 gal -- 18" O.C.

LIRM 23 Liriope muscari / Lily Turf 1 gal -- 18" O.C.

PLANT SCHEDULE

SYMBOL DESCRIPTION DETAIL

RAINBIRD ESP-LXME 12 STATION OUTDOOR

IRRIGATION CONTROLLER ON EQUIPMENT RACK -

SEE SITE ELECTRICAL DRAWINGS

1" METER - BY OWNER

1" WILKENS 950 XLT DOUBLE CHECK BACKFLOW

PREVENTER - MOUNTED BELOW GRADE IN

OLDCASTLE `CARSON` 2436-18" DEEP

ENCLOSURE OR APPROVED EQUAL

M

IRRIGATION LEGEND

00 10' 20'

SCALE: 1" = 10'

TH

ES

E

DR

AW

IN

GS

A

ND

T

HE

D

ES

IG

N

TH

ER

EO

N

AR

E

TH

E

PR

OP

ER

TY

O

F

DA

VI

S

FL

OY

D, IN

C.

A

ND

M

AY

N

OT

B E

US

ED

IN

W

HO

LE

O R

IN

P

AR

T

W

IT

HO

UT

W

RI

TT

EN

C

ON

SE

NT

O F

TH

E

EN

GI

NE

ER

/ A

RC

HI

TE

CT

A

ND

A

NY

IN

FR

IN

GE

ME

NT

W

ILL

B

E

SU

BJ

EC

T

TO

LE

GA

L A

CT

IO

N

K:

\Jo bs ev en \11

0-

\JG

M\

P1

.02

N

GI

P Ph as e 2

\D ra wi ng s\0

4.0

2-

SI

GN

.dw g , 3

/7/

6:

:50

A M, J am es

D . C om pto n, PE

MONUMENT SIGN EXHIBIT

NORTH GREENWOOD INDUSTRIAL PARK

PHASE 2

MARCH, 2025013984.02

N

STATE

PLANE

IRRIGATION NOTES:

CONTRACTOR IS RESPONSIBLE FOR PROVIDING THE DESIGN, MATERIALS AND LABOR TO INSTALL AN IRRIGATION SYSTEM MEETING

THE FOLLOWING REQUIREMENTS:

1. CONTRACTOR SHALL PROVIDE MATERIALS AND LABOR TO TIE THE PROPOSED BACKFLOW PREVENTER INTO A METER THAT SHALL BE PROVIDED BY OWNER. COORDINATE WITH BRIAN WARD AT THE COMMISSIONERS OF PUBLIC WORKS AT (864) 942-8185.

2. THE IRRIGATION SYSTEM SHALL BE CONTROLLED BY AN AUTOMATED IRRIGATION CONTROLLER THAT OPERATES SOLENOID VALVES. GREENWOOD COUNTY IS RESPONSIBLE FOR PROVIDING POWER TO THE SITE. THE CONTRACTOR IS RESPONSIBLE

TO PROVIDE AND INSTALL THE CONTROLLER PER PLAN.

3. CONTROLLER SHALL BE A RAINBIRD ESP-LXME 12 STATION OUTDOOR CONTROLLER WITH A RAINBIRD RSD-BEx RAIN SENSOR

MOUNTED ON EQUIPMENT RACK.

4. TURF AREAS AND BED AREAS SHALL BE ON SEPARATE ZONES. ALL SPRAY HEADS SHALL BE COMMERCIAL GRADE MANUFACTURED BY 'RAINBIRD'. ALL HEADS LOCATED IN TURF AREA SHALL BE POP UP SPRAY OR ROTOR HEADS. USE 1812 POP UP HEADS IN GROUND COVER AREAS, 1806 POP UP HEADS IN PLANTING BEDS AND 1806 POP UP HEADS IN TURF AREAS.

DO NOT MIX POP UP HEADS AND ROTORS ON THE SAME ZONE. DO NOT USE DRIP OR MICRO SPRAY ZONES.

5. ALL VALVES SHALL BE RAINBIRD PEB VALVES WITH PRS-D PRESSURE REGULATORS

6. IRRIGATION MAINLINES AND LATERALS SHALL BE SCHEDULE 40 PVC PIPE. MINIMUM MAINLINE SIZE SHALL BE 11/2”AND

MINIMUM LATERAL SIZE SHALL BE ¾”.

7. THE CONTRACTOR SHALL PROVIDE THE OWNER WITH AN IRRIGATION PLAN FOR APPROVAL PRIOR TO INSTALLATION. THE SYSTEM SHALL FULLY FUNCTION TO PROVIDE UNIFORM COVERAGE TO THE SATISFACTION OF THE OWNER. FLOW VELOCITY IN ALL PIPES SHALL BE KEPT UNDER 5 FPS AND MAINLINE PRESSURE SHALL BE ADJUSTED TO BE BETWEEN 30 PSI 50 PSI.

ADJUSTMENT AT EACH VALVE SHALL BE MADE SO THAT PRESSURE IS DELIVERED TO THE SPRAY HEADS AT THE

MANUFACTURERS RECOMMENDED OPERATING PRESSURE.

8. NO MAINLINES SHALL BE LOCATED WITH IN THE R/W. ALL LATERALS WITH R/W SHALL BE PERPENDICULAR TO HWY 25.

9. THE CONTRACTOR SHALL INITIALLY SET THE PROGRAM TIMES IN A MANNER TO BE AGREED UPON BY THE CONTRACTOR AND OWNER. CONTRACTOR IS RESPONSIBLE FOR ADJUSTMENTS TO WATERING TIMES THEREAFTER UNTIL TURNING THE PROJECT

OVER TO THE OWNER AT FINAL ACCEPTANCE.

10. THE CONTRACTOR SHALL PROVIDE THE OWNER WITH A SET OF 'AS-BUILT' PLANS AFTER IRRIGATION SYSTEM INSTALLATION.

11. THE CONTRACTOR SHALL WARRANTY THE IRRIGATION SYSTEM FOR A PERIOD OF ONE (1) YEAR AFTER FINAL COMPLETION

AGAINST POOR WORMANSHIP AND PRODUCT DEFECTS.

12. ALL WORK SHALL BE IN COMPLIANCE WITH GREENWOOD COUNTY, LOCAL, STATE AND FEDERAL REQUIREMENTS AND

GUIDELINES.

13. RAINBIRD IRRIGATION COMPONENTS ARE SPECIFIED TO MATCH COMPONENTS ALREADY IN USE BY THE COUNTY

MAINTENANCE DEPARTMENT. NO SUBSTITUTIONS.

ABBREVIATION NOTES:

WHERE AN ABBREVIATION IS SHOWN, THE FOLLOWING NOTES APPLY:

- QTY - QUANTITY OF PLANT MATERIAL REQUIRED FOR THE PROJECT. (NOTE: CONTRACTOR RESPONSIBLE TO VERIFY

- QUANTITIES INDICATED. PLAN SHALL TAKE PRECEDENCE OVER SCHEDULE.)

- BOTANICAL/COMMON NAME- PLANT MATERIAL TO BE INSTALLED.

- CONT - CONTAINER TYPE WHICH PLANT MATERIAL IS ENCASED UPON SITE DELIVERY. (HEIGHT AND CALIPER SHALL TAKE

PRECEDENCE OVER CONTAINER.)

- CAL - CALIPER/DIAMETER OF TRUNK. (CALIPER SHALL TAKE PRECEDENCE OVER HEIGHT AND SPREAD.)

- SIZE - HEIGHT AND/OR WIDTH OF PLANT MATERIAL AT INSTALLATION

- SPACING - DISTANCE FROM CENTER OF EACH PLANT. (PLAN SHALL TAKE PRECEDENCE OVER SCHEDULE.)

- REMARKS - SPECIFIC NOTES FURTHER SPECIFYING OR DESCRIBING PLANT MATERIAL.

QUANTITIES NOTES:

PLANT MATERIAL LIST WAS PREPARED FOR ESTIMATING PURPOSES ONLY. QUANTITY ESTIMATES HAVE BEEN MADE CAREFULLY, BUT THE LANDSCAPE ARCHITECT ASSUMES NO LIABILITY FOR OMISSIONS OR ERRORS. CONTRACTORS SHALL MAKE THEIR OWN QUANTITY TAKE-OFFS USING DRAWINGS TO DETERMINE QUANTITIES TO THEIR SATISFACTION, REPORTING PROMPTLY TO THE LANDSCAPE ARCHITECT ANY DISCREPANCIES WHICH MAY AFFECT BIDDING. NO EXTRA COMPENSATION SHALL BE ALLOWED FOR EXTRA QUANTITIES

NECESSARY TO COMPLETE THE WORK.

AutoCAD SHX Text

FO

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

ONLY

TH

ES

E

DR

AW

IN

GS

A

ND

T

HE

D

ES

IG

N

TH

ER

EO

N

AR

E

TH

E

PR

OP

ER

TY

O

F

DA

VI

S

FL

OY

D, IN

C.

A

ND

M

AY

N

OT

B E

US

ED

IN

W

HO

LE

O R

IN

P

AR

T

W

IT

HO

UT

W

RI

TT

EN

C

ON

SE

NT

O F

TH

E

EN

GI

NE

ER

/ A

RC

HI

TE

CT

A

ND

A

NY

IN

FR

IN

GE

ME

NT

W

ILL

B

E

SU

BJ

EC

T

TO

LE

GA

L A

CT

IO

N

K:

\Jo bs ev en \11

0-

\JG

M\

P1

.02

N

GI

P Ph as e 2

\D ra wi ng s\0

4.0

2-

SI

GN

.dw g , 3

/7/

6:

:19

A M, J am es

D . C om pto n, PE

PLANTING DETAILS AND NOTES

NORTH GREENWOOD INDUSTRIAL PARK

PHASE 2

MARCH, 2025013984.02

NOTE: TOP OF ROOTBALL

SHALL BE 4" MIN. HIGHER

THAN ADJACENT GROUND

NOTE: USE PRE-EMERGENT

HERBICIDE AND CONTACT

HERBICIDE AS NEEDED.

OU

TS

ID

E

ED

GE

OF

P

IT

6"

LO

W

ER

TH

AN

B

OT

TO

M

OF

RO

OT

BA

LL

WATER RING

PULL BACK WIRE BASKET AND

BURLAP FROM ROOTBALL AND

DEPRESS INTO BOTTOM OF

HOLE

DIAMETER OF HOLE 2X'S

DIAMETER OF ROOTBALL

DOUBLE GROUND SHREDDED

HARDWOOD MULCH 3" THICK

UNLESS OTHERWISE NOTED

TOPSOIL

BACKFILL - SEE NOTES

FINISH GRADE

112" DBL GROUND HARDWOOD

MULCH WITHIN WATERING RING

NATIVE SOIL

3"

ROUGHEN BOTTOM AND

SIDES OF HOLE EXCAVATION

TO PREVENT GLAZING

TREE PLANTING DETAIL

NTS

FOR 212" CAL. AND LARGER

2" DIA. TREATED WOODEN

POLE - STAKE SHALL NOT PIERCE

ROOTBALL AND SHALL BE DRIVEN

INTO GROUND UNTIL SECURE

TOP OF POLE SHALL BE 23 HEIGHT

OF THE TREE

NATIVE SOIL

FINISHED GRADE

TOPSOIL

BACKFILL - SEE NOTES

MULCH

'ARBOR TIE'

1" WEBBING STRAP

TREE STAKING DETAIL SECTION

NTS

NOTE: TO BE REMOVED AFTER

ONE (1) GROWING SEASON (MAX)

180°

TREE TRUNK

8' TREATED WOODEN

POLE (TYP)

'ARBOR TIE'

1" WEBBING STRAP

TREE STAKING DETAIL

NTS

NOTE:

USE A SMALL HANDFULL OF OSMACOTE

SLOW RELEASE FERTILIZER PER SHRUB

BACK FILL - SEE NOTES112" DOUBLE GROUND

HARDWOOD MULCH WITHIN

WATER RING

3" SHREDDED HARDWOOD MULCH

UNLESS OTHERWISE NOTED

TOPSOIL

6"

2 X ROOTBALL DIA. 2"

H

IG

H

W

AT

ER

R

IN

G

LANDSCAPE FABRIC

SHRUB PLANTING DETAIL

NTS

MI

N.

MI

N.

TURF

PLANTING BED MULCH

COUNTOUR EDGE BED

NTS

6" 12"

Notes:

1. Place plants in bed as shown, spacing as specified in plant schedule

2. Groundcover shall be triangular spaced in rows parallel to straight edges and shall be evenly spaced in rows parallel to curved edges.

3. Settle soil around root ball of each plant prior to mulching.

GROUNDCOVER & PERENNIAL PLANTING DETAIL

NTS

Atypical spacing in corners Space 2 Space Space 2 Space

Space

Space 2 Space

Atypical spacing at end row Stagger plantings

3" Mulch

Finished Grade

Planting Mixture

TOPSOIL

2 X ROOTBALL DIA.

SEE TREE AND SHRUB

PLANTING DETAIL THIS SHEET

NOTE: SLOPE 3:1 OR GREATER

MULCH SHALL BE 4" THICK MIN.

BACKFILL - SEE NOTES

112" DOUBLE GROUND

HARDWOOD MULCH

WITHIN WATER RING

SLOPE PRIOR TO

PLANTING

LANDSCAPE FABRIC

(TREES & SHRUBS) SLOPE PLANTING DETAIL

NTS

CONTRACTOR TO PROVIDE PROTOTYPICAL PLANTING OF AT LEAST 1 TREE, 1 SHRUB AND 1 GROUND COVER FOR REVIEW

AND ACCEPTANCE BY LANDSCAPE ARCHITECT PRIOR TO MASS PLANTING.

NOTE:

SEEDING NOTES

1. EXTENT OF WORK - PROVIDE SOIL ESTABLISHMENT OF FINISH GRADE, PREPARATION, FERTILIZING AND SEEDING, OF ALL NEWLY GRADED FINISHED EARTH SURFACES, UNLESS INDICATED OTHERWISE, AND AT ALL AREAS INSIDE OR OUTSIDE THE LIMITS OF CONSTRUCTION THAT ARE DISTURBED BY THE CONTRACTOR'S

OPERATIONS.

2. TURF ESTABLISHMENT PERIOD - THE ESTABLISHMENT PERIOD FOR TURF SHALL BEGIN IMMEDIATELY AFTER INSTALLATION, WITH THE APPROVAL OF THE ENGINEER, AND CONTINUE UNTIL THE DATE THAT THE OWNER ACCEPTS THE PROJECT OR PHASE FOR BENEFICIAL USE AND OCCUPANCY AND A STAND OF GRASS IS

ACHIEVED. DURING THE TURF ESTABLISHMENT PERIOD THE CONTRACTOR SHALL:

A. WATER THE TURF TO MAINTAIN AN ADEQUATE SUPPLY OF MOISTURE WITHIN ROOT ZONE. AN ADEQUATE SUPPLY OF MOISTURE IS THE EQUIVALENT OF 1 INCH OF ABSORBED WATER PER WEEK EITHER THROUGH NATURAL RAINFALL OR AUGMENTED BY PERIODIC WATERING. APPLY WATER AT

A MODERATE RATE SO AS NOT TO FLOOD THE TURF.

B. PROVIDE THE FOLLOWING TURF ESTABLISHMENT:

1. ERADICATE ALL WEEDS. WATER, FERTILIZE, OVERSEED, AND PERFORM ANY OTHER OPERATION

NECESSARY TO PROMOTE THE GROWTH OF GRASS.

2. RESEED AREAS VOID OF TURF ONE SQUARE FOOT AND LARGER IN AREA.

3. MOW THE NEW LAWN AT LEAST THREE TIMES PRIOR TO THE FINAL INSPECTION.

BEGIN MOWING WHEN GRASS IS 4 INCHES HIGH. MOW TO A 212 INCH HEIGHT.

3. PERMANENT GRASS SEEDING RATES- SEED MIXTURE (FOR AREA INDICATED ON PLAN TO

RECEIVE SAHARA BERMUDA SEED.)

PLANTING SEASON VARIETY LB/ 100 S.F.

SPRING/SUMMER

(APRIL 1 - AUG. 31)

BROWN TOP MILLET 1/2 LB.

HULLED BERMUDA GRASS (SAHARA) 2 LBS.

FALL/WINTER

(SEPT 1. - MAR. 31)

ANNUAL RYE GRASS 6 LBS.

HULLED BERMUDA GRASS 1 LB.

UNHULLED BERMUDA GRASS (SAHARA) 3 LBS.

NOTE: SOME ANNUAL GRASS SPECIES ARE INCLUDED IN THIS MIX. THESE ARE TO BE PLANTED AT THE SAME TIME AS THE PERENNIAL GRASS SPECIES TO PROVIDE QUICK COVER AND STABILIZE THE SOIL UNTIL THE

PERENNIAL SEEDS GERMINATE AND BECOME ESTABLISHED.

4. WOOD CELLULOSE FIBER MULCH - USE RECOVERED MATERIALS OF EITHER PAPER-BASED (100 PERCENT) OR

WOOD-BASED (100 PERCENT) HYDRAULIC MULCH. PROCESSED TO CONTAIN NO GROWTH OR

GERMINATION-INHIBITING FACTORS AND DYED AN APPROPRIATE COLOR TO FACILITATE VISUAL METERING OF MATERIALS APPLICATION. COMPOSITION ON AIR-DRY WEIGHT BASIS: 9 TO 15 PERCENT MOISTURE, pH RANGE

FROM 3.5 TO 5.0. USE WITH

HYDRAULIC APPLICATION OF GRASS SEED AND FERTILIZER. FIRST, MIX WATER AND FIBER. FIBER SHALL BE ADDED AT 1,000 POUNDS, DRY WEIGHT, PER ACRE. THEN ADD FERTILIZER TO PRODUCE A HOMONGENEOUS SLURRY. WHEN HYRDAULICALLY SPRAYED ON THE GROUND, MATERIAL SHALL FORM A BLOTTER LIKE COVER IMPREGANTED UNIFORMLY WITH GRASS SEED. APPLY SEEDED SLURRY EVENLY IN TWO INTERSECTION

DIRECTIONS TO ACHIEVE A MINIMUM 60% COVERAGE.

5. SOIL ANALYSIS - IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO HAVE A SOIL ANALYSIS PERFORMED BY THE COUNTY EXTENSION SERVICE OR SOME OTHER APPROVED LABORATORY FOR A SOIL ANALYSIS REPORT.

THE CONTRACTOR SHALL THEN PROVIDE THE RECOMMENDATIONS OF THE REPORT TO THE ENGINEER FOR WRITTEN APPROVAL. RECOMMENDATIONS SHALL ENSURE THAT SOIL pH IS WITHIN 6-7 PRIOR TO SEEDING AND

SHALL INCLUDE RATES FOR LIME, AND FERTILIZER.

6. SOIL PREPARATION - PRIOR TO MASS GRADING, REMOVE EXISTING TOPSOIL TO A MINIMUM DEPTH OF 6" AND STOCKPILE. IF AREAS TO BE GRADED ARE COVERED WITH GRAVEL, COMPLETELY REMOVE GRAVEL AND DISPOSE OF OFF-SITE IN A MANNER THAT COMPILES WITH ALL LOCAL, STATE, AND FEDERAL LAWS. AFTER AREAS HAVE BEEN BROUGHT TO FINISH SUBGRADE ELEVATION, THOROUGHLY TILL TO MINIMUM DEPTH OF 6 INCHES BY SCARIFYING, DISKING OR HARROWING. REMOVE DEBRIS AND STONES LARGER THAN ONE INCH IN ANY DIMENSION REMAINING ON SURFACE AFTER TILLAGE. SPREAD STOCKPILED OR HAULED IN TOPSOIL EVENLY TO A MIN. DEPTH OF 6" TO PROVIDE POSITIVE DRAINAGE. DO NOT SPREAD TOPSOIL WHEN FROZEN OR EXCESSIVELY WET OR DRY. CORRECT IRREGULARITIES IN FINISHED SURFACES TO ELIMINATE DEPRESSIONS.

PROTECT FINISHED PREPARED SOIL AREAS FROM DAMAGE BY VEHICULAR OR PEDESTRIAN TRAFFIC.

GENERAL PLANTING NOTES

-SEE SPECIFICATIONS

1. PLANTER PIT BACKFILL MIX FOR ALL TREES AND SHRUBS SHALL BE:

-- 2 PARTS CLEAN LOAMY TOPSOIL

-- 1 PART DIRT FROM HOLE

SEE DETAIL THIS SHEET

2. PLANTING BED PREPARATION:

AFTER MASS GRADING USE TOPSOIL FOR USE IN PLANTING BEDS FROM A RELIABLE LOCAL SOURCE, FREE OF

WEEDS AND DEBRIS. SOURCE SHALL CERTIFY THAT TOPSOIL IS FREE OF ALL NOXIOUS WEEDS. DO NOT USE

TOPSOIL IN PLANTING BEDS THAT HAS BEEN STRIPPED FROM THE SITE.

3. MULCH WITH DOUBLE GROUND HARDWOOD MULCH 3" THICK MIN. SUBMIT SAMPLE TO OWNER FOR APPROVAL.

4. FINAL GRADING FOR GRASSED AND LANDSCAPED AREAS SHALL REQUIRE A MINIMUM OF 6" OF CLEAN TOP SOIL FREE OF DEBRIS, CONTAMINANTS AND PREFERABLE OF NATIVE ORIGIN. TOPSOIL FROM SITE SHALL BE USED FOR SEED

AREAS. FOR TOPSOIL IN PLANTING BEDS, SEE NOTE 2 ABOVE.

5. SOIL AMENDMENTS, VITAMINS AND HORMONES:

5.1. APPLY BURNNING 'GYPSUM CLAY BREAKER' OR EQUAL TO ALL PROPOSED TREE, SHRUB AND GROUND COVER

PLATING HOLES, PER MANUFACTURERS' RECOMMENDATIONS.

5.2. APPLY 'SUPERTHRIVE' VITAMINS AND HORMONES TO ALL TREES, SHRUBS AND GROUNDCOVERS PER

MANUFACTURERS' RECOMMENDATIONS. www.superthrive.com (800) 441-VITA -NO SUBSTITUTIONS.

6. CONTRACTOR SHALL PROVIDE ALL MATERIALS AND LABOR TO PERFORM THE SCOPE OF WORK DESCRIBED IN THE

NOTES, DETAILS, AND PLANS UNLESS OTHERWISE INDICATED.

7. THE CONTRACTOR IS TO PROTECT ALL EXISTING STRUCTURES AND TREES INCLUDING BUT NOT LIMITED TO BUILDINGS, CONCRETE CURB, CONCRETE WALKS, RETAINING WALLS AND TREES, UNDER GROUND UTILITIES WHICH ARE CLEARLY MARKED. THE CONTRACTOR IS RESPONSIBLE FOR HAVING UTILITIES MARKED BY PALMETTO UTILITY LOCATING SERVICE (1-800-922-0983) SUPPLY THEM WITH THE FOLLOWING INFORMATION - ADDRESS (INSIDE CITY LIMITS), OWNERS' NAME, COMPLETION DATE, CONTRACTORS' NAME, CONTACT PERSON, CONTACT PERSON

TELEPHONE NUMBER.

8. WARRANTY - WARRANT TREES AND SHRUBS TO REMAIN ALIVE FOR A PERIOD OF 1 YEAR AFTER COMPLETION AND

ACCEPTANCE OF ENTIRE PROJECT.

TURF GUARANTEE: THE CONTRACTOR SHALL GUARANTEE A SATISFACTORY

STAND OF GRASS WITHIN NINETY (90) DAYS. IF, AT THE END OF THAT TIME, THE OWNER

IS NOT SATISFIED, THE CONTRACTOR SHALL REMOVE DEAD TURF, AND RESEED AND APPLY

FERTILIZER TO PROBLEM AREAS AT A RATE TO SATISFY THE OWNER. THE CONTRACTOR IS

RESPONSIBLE FOR REPAIRING WASHED OUT AREAS AND RUTS WHICH DEVELOP DUE TO STORM

WATER RUNOFF UNTIL THE OWNER IS SATISFIED.

ENTRANCE SIGN SCHEMATIC

C

C

C C

B

(1)1" CND (2)1" CND

(1)1" CND

C

C

SEE 'FLOODLIGHT BASE DETAIL'

SHEET E002 FOR MORE INFORMATION,

TYP OF 6.

ELECTRICAL EQUIPMENT RACK

B

B

B

B

B A

A

A

A

A

A

A

A

GENERAL NOTES:

COORDINATE INSTALLATION OF UNDERGROUND DUCT/CONDUIT WITH

ALL OTHER UNDERGROUND UTILITIES. INSTALL UNDERGROUND

DUCT/CONDUIT TO AVOID INTERFERING WITH OTHER UNDERGROUND

UTILITIES.

ALL CONDUIT SHALL BE DIRECT BURIED UNLESS OTHERWISE NOTED.

ALL CONDUIT SHALL BE RIGID GALVANIZED STEEL, EXCEPT THAT

UNDERGROUND CONDUIT SHALL BE PVC, SCHEDULE 40 DIRECT BURIED

UNLESS OTHERWISE NOTED.

SEE 'POWER RISER' ON SHEET E001 FOR MORE INFORMATION ON

CONDUIT AND WIRING.

1.

2.

3.

4.

EXST UTILITY DIP POLE WITH

TRANSFORMER PROVIDED

BY DUKE ENERGY

UNDERGROUND SERVICE FEEDER

SUPPLIED BY DUKE ENERGY

ELECTRICAL EQUIPMENT RACK.

SEE 'DETAIL - ELECTRICAL EQUIPMENT RACK',

REFER TO 'SLEEVE INSTALLATION

DETAIL - SECTION,'

00 50' 100'

SCALE: 1" = 50'

TH

ES

E

DR

AW

IN

GS

A

ND

T

HE

D

ES

IG

N

TH

ER

EO

N

AR

E

TH

E

PR

OP

ER

TY

O

F

DA

VI

S

FL

OY

D, IN

C.

A

ND

M

AY

N

OT

B E

US

ED

IN

W

HO

LE

O R

IN

P

AR

T

W

IT

HO

UT

W

RI

TT

EN

C

ON

SE

NT

O F

TH

E

EN

GI

NE

ER

/ A

RC

HI

TE

CT

A

ND

A

NY

IN

FR

IN

GE

ME

NT

W

ILL

B

E

SU

BJ

EC

T

TO

LE

GA

L A

CT

IO

N

K:

\Jo bs ev en \11

0-

\JG

M\

P1

.02

N

GI

P Ph as e 2

\D ra wi ng s\0

4.0

2-

SI

GN

E

XH

IB

IT

.dw g , 3

/11 /20

:50 :17

P M, G eo rg e D ou gla ss

MONUMENT SIGN ELECTRICAL

EXHIBIT

NORTH GREENWOOD INDUSTRIAL PARK

PHASE 2

MARCH 2025013984.02

N

ST

AT

E

PL

AN

E

ELECTRICAL SITE PLAN

SCALE: 1" = 50'

ENLARGED LIGHTING PLAN

SCALE: 1" = 10'

NOTE:

THE SETBACKS LISTED MAY DIFFER FROM SETBACK REQUIRED. COORDINATE SETBACK

DIMENSIONS IN ACCORDANCE WITH LIGHT MANUFACTURER'S RECOMMENDATION.

1.

AROUND CHANNEL

CONCRETE ALL

PROVIDE 3" MIN.

3"

FINISH

GRADE

6"

24"

AS NECESSARY

4" GALVANIZED

STEEL CHANNEL

1-5/8" GALV.

STEEL UNISTRUT

NTS

SECTION ELEVATION

NOTES:

DETAIL - ELECTRICAL EQUIPMENT RACK

ALL EQUIPMENT RACK HARDWARE SHALL BE STAINLESS STEEL.

PROVIDE GROUND ROD AND CONNECT IN ACCORDANCE WITH

SPECIFICATIONS. SEE 'POWER RISER', SHEET E601 FOR MORE

INFORMATION.

SEE 'POWER RISER' ON SHEET E001 FOR MORE INFORMATION.

1.

2.

3.

100A SELF-CONTAINED 120/240V SINGLE PHASE METER BASE. SUPPLIED BY DUKE ENERGY.

COORDINATE INSTALLATION WITH DUKE ENERGY.

60A, 120/240V, SINGLE PHASE PANEL 'A'. SEE PANEL SCHEDULE.

WEATHERPROOF HINGED ENCLOSURE WITH 3POLE, 30AMP, LIGHTING CONTACTOR WITH

CONTACTOR AUTOMATICALLY CONTROLLED BY PHOTOCELL, (3) HEAVY DUTY DIMMING SWITCHES

FOR LIGHTING CIRCUITS. ONE SWITCH PER CIRCUIT. SWITCH TO BE 120V, 0-10V RATED.

BASIS OF DESIGN: LEGRAND WS4FBL3PTC OR EQUAL.

RAINBIRD IRRIGATION CONTROLLER, 8 STATION, 120V, WEATHERPROOF

ENCLOSURE.

120V PHOTOCELL FOR SIGN LIGHTS AND TREE LIGHTS. BASIS OF DESIGN: INTERMATIC

K4200 SERIES MODEL NUMBER EK4736S OR EQUAL.

20A, 120V GFCI RECEPTACLE WITH WEATHERPROOF, WHILE-IN-USE

COVER. POWER FROM PANEL.

A

B

C

D

E

F

T/SLAB

3/4" DIA. A325-N

BOLTS U.N.O.

L3x3x1/4

AS REQUIRED

DB

C

E

F

A

EQUIPMENT TAGS

3/4" CHAMFER

NOTE:

NTS

FLOODLIGHT BASE DETAIL

SCHEDULE 40

PVC CONDUIT FOR

CIRCUIT CONTINUATION.

LIGHT FIXTURE,

SEE LIGHTING

FIXTURE SCHEDULE,

SHEET E001.

4" MA

X

4" MA

X

GRADE

8" DIAMETER

BY 16" DEEP

CONCRETE BASE

APPLIES TO FIXTURE 'C'.

00 10' 20'

SCALE: 1" = 10'

MIN.

MIN.

NOTE: ALL PIPING WITHIN SCDOT RIGHT-OF-WAY

SHALL CONFORM TO SCDOT SUPPLEMENTAL

SPECIFICATION SC-M-714

NO SCALE

SLEEVE INSTALLATION DETAIL - SECTION

12"

36" MIN.

3"

TOP OF FINISH GRADE TURF ON TOP SOIL

2 (TWO) 3" AND 1 (ONE)

2" SCH. 40 PVC SLEEVES

UNLESS OTHERWISE NOTED

-SEE PLAN

STRUCTURAL DIRT

BACKFILL - COMPACTED TO

98% STANDARD PROCTOR

COMPACTED SUBGRADE

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text G

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

ONLY

File details come from the government source that posted it. Updated .