Design drawings dolley painting.pdf
PDF 6 MB Posted
- Solicitation number
- CAFC-8-28-2026
- Issued by
-
Administrative Office of the U.S. Courts
About this file
Summary: Historic Townhouses Envelope Repairs – Construction Documents (100% Submission)
This is a comprehensive set of architectural and structural construction documents for preservation and minor rehabilitation work on three historic townhouses located at 717 Madison Place, NW, Washington, DC 20005-7700. The project scope encompasses the Madison House (Dolley Madison House), Cosmos Club, and Tayloe House. The work is being executed under GSA General Services Administration auspices via IDIQ Contract #47PF0019D0048, Task Order #47PM0122F0003, with architectural services provided by Architrave P.C. Architects, structural services by McMullan & Associates, engineering by James Posey Associates, and cost estimating by RIB US Cost.
The project prioritizes historic preservation standards, including compliance with the Secretary of the Interior's Standards for Rehabilitation and National Park Service guidelines. Key work elements include hazardous materials abatement (asbestos-containing materials and lead-based paint identified in prior assessment reports), masonry repointing and repair using mortar matching existing composition and color, window and door restoration or replacement, roof repairs including slate shingle replacement and flashing work, structural stabilization with temporary shoring and bracing, drainage system rehabilitation, and metal restoration (wrought iron balconies, gutters, downspouts, and conductor heads). The documents specify extensive pre-construction testing for mortar composition, mock-up preparation for COR approval at each building, and Level B masonry inspection. Design loads include 30 PSF ground snow load, 115 MPH ultimate wind speed, and seismic design category B. The contractor bears responsibility for all means and methods, including engagement of a licensed structural engineer to conduct pre-demolition surveys and provide weekly monitoring reports. Testing and inspection services are required under District of Columbia requirements with final reports submitted within ten days.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Response to Questions Submitted for CAFC Exterior Painting RFQ.docx | DOCX document | |
| SOW Dolley Exterior Painting.pdf | ||
| NCB Contractor Access Requirements.pdf | ||
| RFQ Dolley Madison Exterior Painting 8.28.2026.docx | DOCX document | |
| Dolley Specifications.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LOCATION MAP
DISTRICT OF
COLUMBIA
PROJECT SITE
PROPERTY OF THE UNITED STATES GOVERNMENT This is controlled unclassified information. Do not remove the CUI marking. Properly destroy or return documents when no longer needed.
CHECKED BY
DRAWN BY
FLOOR NUMBER
SHEET TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
PROJECT NUMBER
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NUMBER
CITY/ST./ZIP
ADDRESS
BUILDING NAME
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
24 X 36
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N T
R A
C T
O R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
S
T A
M P
O R
S E
A L
D E
S
IG
N E
R
ID
E N
T
IF
IC
A
T
IO
N O
W N
E R
ID
E
N T
IF
IC
A T
IO
N
SHEET OF SHEETS
architrave p.c. architects
420 10th ST. S.E.
Washington D.C. 20003
202-544-1640
/2
/2
:2 :1
P
M
G-001
COVER SHEET
HISTORIC TOWNHOUSES ENVELOPE REPAIRS
FINAL CD SUBMISSION (100%)
1/24/25
11/26/24TS
RLS
RDC04752, RDC04736, RDC04732
GENERAL SERVICES
ADMINISTRATION
MADISON HOUSE, COSMOS CLUB,
& TAYLOE HOUSE
717 MADISON PLACE, NW
WASHINGTON, DC 20005-7700
DC0111ZZ_B1-03_A_22
47PF0019D0048
47PM0122F0003
architrave p.c. architects
McMullan & Associates
DC0111ZZ, DC0112ZZ, DC0113ZZ
MADISON HOUSE, COSMOS CLUB, & TAYLOE HOUSE
717 MADISON PLACE NW
WASHINGTON, DC 20005
PRESERVATION AND MINOR REHABILITATION
BRIAN KEEFER
N/A
ARCHITECTURAL
G-001 COVER SHEET
S-001 DESIGN NOTES
S-002 DESIGN NOTES & ABBREVIATIONS
S-101 OVERALL FIRST FLOOR PLAN
S-102 OVERALL ROOF PLAN
S-201 PLANS
S-202 ROOF FRAMING PLANS
S-501 SECTIONS AND DETAILS
S-502 SECTIONS AND DETAILS
S-503 SECTIONS AND DETAILS
S-504 SECTIONS AND DETAILS
A-001 NOTES & ABBREVIATIONS
A-002 KEY TO SCHEDULES
A-003 SITE/ACCESS PLAN
A-101 MADISON HOUSE FIRST FLOOR PLAN
A-102 MADISON HOUSE SECOND AND THIRD FLOOR PLAN
A-103 MADISON HOUSE ROOF PLAN
A-104 COSMOS CLUB FIRST, SECOND, THIRD, FOURTH FLOOR
A-105 COSMOS CLUB FIFTH FLOOR AND RCP
A-106 COSMOS CLUB ROOF PLAN
A-107 TAYLOE HOUSE FIRST, SECOND, THIRD FLOOR PLAN
A-108 TAYLOE HOUSE ATTIC AND ROOF PLANS
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
WASHINGTON, DC 20006
100% SUBMISSION
ARCHITECTURAL SERVICES
architrave p.c. architects
420 10th Street, SE
Washington, DC 20003
IDIQ CONTRACT #47PF0019D0048
TASK ORDER #47PM0122F0003
HISTORIC TOWNHOUSES ENVELOPE REPAIRS
D. MADISON HOUSE, TAYLOE HOUSE & COSMOS CLUB
717 MADISON PLACE, NW, WASHINGTON DC, 20005-7700
STRUCTURAL SERVICES
McMullan and Associates
11800 Sunrise Valley DR #430
Reston, VA, 20191
VICINITY MAP
LOCATION MAP
INDEX OF DRAWINGS
1. A PRE-ALTERATION ASSESSMENT WAS CONDUCTED IN MARCH 2022 FOR HAZARDOUS MATERIALS, INCLUDING ASBESTOS-CONTAINING MATERIALS (ACM), AND LEAD-BASED PAINT (LBP). THE
“LIMITED REGULATED MATERIAL SURVEY REPORT” DESCRIBES THE LOCATIONS AND FINDINGS OF
THE SURVEY IS ON FILE FOR REVIEW AND USE.
2. ACM ARE PRESENT IN EACH BUILDING. HANDLE, REMOVE, AND DISPOSE OF ACM FOLLOWING
SECTION 020850.
a. ASBESTOS-CONTAINING CAULKING IS PRESENT IN THE GLAZING COMPONENT OF EACH
WINDOW AND DOOR ASSEMBLY.
b. MADISON HOUSE: SEAM SEALANT ON CANVAS PIPE WRAPS, CANVAS PIPE WRAPS, PLASTER
WALLS, GYPSUM BOARD CEILINGS, PLASTER CEILINGS, FIRE BRICKS ON FIREPLACES, AND
ROOFING COMPONENTS CONTAIN ACM.
c. COSMOS CLUB: PIPE INSULATION AND SEAM SEALANT ON CANVAS PIPE WRAPS, SEALANT
ON BARE METAL DUCTS, GYPSUM BOARD CEILING JOINT COMPOUND, DECORATIVE
PLASTERS, SKIM-COAT OVER BRICKS, AND ROOFING COMPONENTS CONTAIN ACM.
d. TAYLOE HOUSE: PIPE INSULATION AND WRAPS, SPRAY-ON FIREPROOFING, GYPSUM BOARD
CEILING JOINT COMPOUND, DECORATIVE PLASTERS, AND ROOFING COMPONENTS CONTAIN
ACM.
3. LBP ARE PRESENT IN EACH BUILDING: HANDLE, REMOVE, AND DISPOSE OF LBP FOLLOWING
SECTION 020900.
a. ALL BUILDINGS: WINDOW SYSTEMS AND THEIR COMPONENTS, WOOD DOORS CONTAIN LBP
ON THE INTERIOR AND EXTERIOR SURFACES, GUTTERS AND DOWNSPOUTS
b. MADISON HOUSE: EXTERIOR PAINT ON STUCCO, PAINT ON STONE SILLS AND LINTELS
CONTAIN LBP. ASSUME LPB ON EXTERIOR UPPER STORY WOOD AND METAL SOFFITS,
FASCIA, AND DECORATIVE ELEMENTS.
c. COSMOS CLUB: FIFTH FLOOR WALLS ABOVE CHAIR RAIL, METAL I-BEAMS (ORANGE PAINT) IN
FIFTH FLOOR CONTAIN LBP. ASSUME LBP ON WROUGHT-IRON BALCONIES AND WINDOW
WELL GRILLS.
d. TAYLOE HOUSE: EXTERIOR BRICK WALLS AND CHIMNEYS, WINDOW SHUTTERS, WINDOW
WELLS CONTAIN LBP. ASSUME LBP ON WINDOW WELL GRILLS, BALCONY WROUGHT IRON
ELEMENTS, EAST FAÇADE VENTS, DOWNSPOUTS, UPPER STORY WOOD AND METAL
SOFFITS, FASCIA, AND DECORATIVE ELEMENTS.
4. IF THE CONTRACTOR ENCOUNTERS OTHER MATERIALS SUSPECTED TO CONTAIN REGULATED
MATERIAL (HAZARDOUS MATERIALS), CEASE DEMOLITION / REMOVAL ACTIVITIES; NOTIFY
CONTRACTING OFFICER AND CONDUCT ASBESTOS AND LEAD PAINT CHIP SAMPLING AND
TESTING. BASED ON FINDINGS FOLLOW REQUIREMENTS OF SECTIONS 02850 FOR ACM REMOVAL
AND DISPOSAL AND 020900 FOR LBP REMOVAL AND DISPOSAL.
A-200 MADISON HOUSE ELEVATIONS
A-201 COSMOS CLUB ELEVATIONS
A-202 TAYLOE HOUSE ELEVATIONS
A-400 MADISON HOUSE ABA LIFT PLANS AND SECTIONS
A-401 COSMOS CLUB ENLARGED DETAILS
A-402 COSMOS CLUB ENLARGED DETAILS
A-403 COSMOS CLUB ENLARGED DETAILS
A-404 TAYLOE HOUSE ENLARGED DETAILS
A-405 TAYLOE HOUSE ENLARGED DETAILS
A-500 MADISON HOUSE WINDOW AND DOOR DETAILS
A-501 MADISON HOUSE WINDOW AND DOOR DETAILS
A-502 COSMOS CLUB WINDOW AND DOOR DETAILS
A-503 TAYLOE HOUSE WINDOW AND DOOR DETAILS
A-504 MASONRY REPAIR DETAILS
A-505 ROOF REPAIR DETAILS
A-506 ROOF REPAIR DETAILS
A-507 ABA LIFT DETAILS
A-600 MADISON HOUSE WINDOW SCHEDULE
A-601 COSMOS CLUB WINDOW SCHEDULE
A-602 TAYLOE HOUSE WINDOW SCHEDULE
A-603 WINDOW TYPES
A-604 SCHEDULES, DOOR, PAINTING, DOWNSPOUT
E-100 MADISON HOUSE PLAN - ELECTRICAL
HAZMAT NOTES
COST ESTIMATING SERVICES
RIB US Cost
4640 Forbes Boulevard, Suite 325, Lanham, MD 20706
Mark Date Description
ENGINEERING SERVICES
James Posey Associates
11155 Red Run Blvd, Owings Mills, MD 21117
D
I S
T
R
I
C
T
O F
A
I
B
M
U
L
O
C
P
R
O
F
E
S
S
I O
N
AL
R
E
E
N
I
G
N
E
R
D E
G
I
S
T E
R
E
PE905872
S
A
M
M
.C
O
T H
I
P
L
P
I
N
G
E
R
WORK IS TO ONLY BE P
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
DESIGN NOTES
CODES AND STANDARDS
A. WORK IN ACCORDANCE WITH REQUIREMENTS OF FACILITIES STANDARDS
FOR PUBLIC BUILDINGS SERVICE (P100) WITH 2022 ADDENDUM AND THE
INTERNATIONAL BUILDING CODE, 2021.
B. USE THE CURRENT VERSION OF ALL CODES, REFERENCES AND STANDARDS
REFERRED UNLESS A DIFFERENT VERSION IS LISTED IN THE BUILDING CODE.
DESIGN AND LOADING CRITERIA
A. SNOW LOAD
1. GROUND SNOW LOAD: (PG) = 30.0 PSF
2. SNOW EXPOSURE FACTOR (CE): = 1.0
3. IMPORTANCE FACTOR (I): = 1.0
4. THERMAL FACTOR (CT): = 1.0
5. FLAT ROOF SNOW LOAD (PF): = 21.7 PSF
B. SEISMIC LOAD
1. RISK CATEGORY: = II
2. SEISMIC IMPORTANCE FACTOR (I): = 1.0
3. MAPPED SPECTRAL RESPONSE: SS = 0.133, S1= 0.043
4. SPECTRAL RESPONSE COEFF SDS = 0.142, SD1= 0.069
5. SITE CLASSIFICATION: = D
6. SEISMIC DESIGN CATEGORY = B
7. RESPONSE MODIFICATION FACTOR: R = 1.5
C. WIND LOAD
1. ULTIMATE WIND SPEED: = 115 MPH
2. RISK CATEGORY: = II
3. EXPOSURE: = B
4. INTERNAL PRESSURE COEFF: = +/- 0.18
5. COMPONENT AND CLADDING:
FOR WALL = [XX] PSF MAX
FOR ROOF = [XX] PSF MAX
FOR PARAPET = [XX] PSF MAX
OTHER DESIGN PRESSURES MAYBE USED IF SIGNED & SEALED
CALCULATIONS ARE SUBMITTED FOR REVIEW
D. FLOOR DESIGN MINIMUM LIVE LOADS:
1. OFFICES: = 50 PSF + 20 PARTITION
2. PORCH = 100 PSF
3. ROOFS: = FLAT ROOF SNOW LOAD IN ADDITION TO APPLICABLE
SNOW DRIFTING CONSIDERATION.
CONCRETE AND REINFORCING
A. PROVIDE CONCRETE WORK IN ACCORDANCE WITH "BUILDING CODE
REQUIREMENTS FOR STRUCTURAL CONCRETE", ACI 318. AS MODIFIED BY IBC
CODE.
B. CONCRETE DESIGN IS IN ACCORDANCE WITH "STRENGTH DESIGN METHOD."
C. PROVIDE CONCRETE MIX WITH ULTIMATE COMPRESSIVE STRENGTH AT 28
DAYS (F'C)=5000PSI CLASS C0,S0,F1,W0
D. CONCRETE MATERIALS:
1. CEMENT: ASTM C-150 TYPE I OR III
2. CEMENT SUBSTITUTES: ASTM C-595 TYPE '1P' (LIMIT TO 25% MAXIMUM
CEMENTITIOUS CONTENT BY WEIGHT.)
3. AGGREGATES: ASTM C-33 (NORMAL WEIGHT)
ASTM C-330 (STRUCTURAL LIGHTWEIGHT)
4. AIR-ENTRAINING ADMIX: ASTM C-260
5. ISOLATION JOINT FILLER: ASTM D-1751
6. JOINT SEALANT: ASTM C-920
E. CONCRETE EXPOSED TO WEATHER SHALL BE AIR-ENTRAINED 6%, +/- 1%.
F. THOROUGHLY COMPACT CONCRETE DURING PLACEMENT AND WORK
AROUND EMBEDDED ITEMS AND INTO CORNERS OF FORMS.
G. LOCATE AND SECURE ALL ITEMS TO BE EMBEDDED IN CONCRETE. VERIFY
LOCATION OF EMBEDMENT PLATES PRIOR TO CONCRETE PLACEMENT.
H. LOCATE DEPRESSIONS ACCORDING TO ARCHITECTURAL PLANS.
COORDINATE PENETRATIONS FOR MECHANICAL, PLUMBING AND ELECTRICAL
WORK WITH MECHANICAL, PLUMBING AND ELECTRICAL ENGINEERING AND
ARCHITECTURAL DRAWINGS.
I. PROVIDE CONCRETE SLUMP = 4" PLUS OR MINUS 1".
J. PROVIDE KEYED JOINTS BETWEEN ALL NON-MONOLITHIC CONCRETE JOINTS.
K. PROVIDE GROUT THAT IS NON-SHRINKABLE, NON-METALLIC CONFORMING TO
ASTM C1107, AND SHALL HAVE A SPECIFIED COMPRESSIVE STRENGTH AT 28
DAYS OF 7,000 PSI. PREGROUTING OF BASE PLATES SHALL NOT BE
PERMITTED.
L. PROVIDE DEFORMED REINFORCING BARS #3 THRU #11 IN ACCORDANCE
WITH "SPECIFICATIONS FOR DEFORMED AND PLAIN BILLET STEEL BARS FOR
CONCRETE REINFORCEMENT" ASTM A-615. GRADE 60 KSI.
M. SUBMIT SHOP DRAWINGS FOR REINFORCEMENT TO THE COR FOR
APPROVAL. PREPARE DRAWINGS UNDER THE SUPERVISION OF A
PROFESSIONAL STRUCTURAL ENGINEER REGISTERED IN THE LOCAL
JURISDICTION DETAILING FABRICATING, BENDING, AND PLACING CONCRETE
REINFORCEMENT. COMPLY WITH ACI 315 AND ACI DETAILING MANUAL SP-66,
SHOWING BAR SCHEDULES, STIRRUP SPACING, BENT BAR DIAGRAMS, AND
ARRANGEMENT OF CONCRETE REINFORCEMENT.
N. PROVIDE BARS MARKED CONTINUOUS (CONT) THAT ARE LAPPED IN
ACCORDANCE WITH REQUIREMENTS FOR SPLICES AS DEFINED IN ACI 318,
MINIMUM 50 BAR DIAMETERS, UNLESS INDICATED OTHERWISE.
O. BAR LENGTHS SHOWN ON PLAN DO NOT INCLUDE LENGTH OF HOOK WHERE
A HOOK IS INDICATED. PROVIDE STANDARD HOOK UNLESS DETAILED
OTHERWISE.
P. PROVIDE MINIMUM CONCRETE COVER BETWEEN FACE OF REINFORCING BAR
AND FACE OF CONCRETE AS FOLLOWS:
1. CONCRETE CAST AGAINST EARTH = 3"
2. FORMED CONCRETE EXPOSED TO WEATHER OR EARTH = 2"
Q. PROVIDE RIGID INSULATION SUPPORTING NEW CONCRETE SLABS WITH THE
FOLLOWING MINIMUM PROPERTIES:
1. EXTRUDED POLYSTYRENE ASTM D6817
2. COMPRESSIVE STRENGTH: 50 PSI (@10% DEFORMATION PER ASTM
D-1621)
3. ELASTIC MODULUS: 1500 PSI
4. FLEXURAL STRENGTH: 60PSI
5. DENSITY: 2.4 PCF
STRUCTURAL STEEL
A. PROVIDE STRUCTURAL STEEL THAT IS DESIGNED, FABRICATED AND
ERECTED IN ACCORDANCE WITH "SPECIFICATION FOR STRUCTURAL STEEL
BUILDINGS AND THE "MANUAL OF STEEL CONSTRUCTION" FIFTEENTH
EDITION.
B. STRUCTURAL STEEL:
1. STRUCTURAL "W" & "T" SHAPES: ASTM A-992 FY = 50,000 PSI
2. BALANCE OF STEEL SHAPES & PLATES: ASTM A-36 FY = 36,000 PSI
3. HIGH STRENGTH BOLTS: ASTM F3125, GR A-325 CONN
TYPE-N
4. ANCHOR RODS: ASTM F-1554 GR36 OR GR 55
WITH WELDABILITY
SUPPLEMENT S1.
5. GALVANIZING (HOT-DIP): ASTM A-123
C. ALTERNATE CONNECTIONS TO THOSE SHOWN ON PLANS AND DETAILS WILL
BE ALLOWED ONLY WITH THE APPROVAL OF THE COR. IF SUCH APPROVAL
IS GRANTED FOR ANY CONNECTIONS NOT IN ACCORDANCE WITH CONTRACT
DOCUMENTS (FABRICATOR'S REDESIGN), THEN SUBMIT SHOP DRAWING FOR
ALTERNATE CONNECTIONS UNDER THE SEAL OF LICENSURE OF THE
FABRICATOR'S ENGINEER FOR THE LOCAL JURISDICTION.
D. PROVIDE A-325 BOLTS TIGHTENED TO THE "SNUG TIGHT" CONDITION, UNO,
THAT IS DEFINED AS THE TIGHTNESS ATTAINED BY A FEW IMPACTS OF AN
IMPACT WRENCH OR THE FULL EFFORT OF A MAN USING AN ORDINARY SPUD
WRENCH UNLESS OTHERWISE NOTED. ALL THE PLIES OF THE CONNECTED
MATERIAL MUST BE INTO FIRM CONTACT TO CONFIRM THE SNUG TIGHT
CONDITION.
E. PROVIDE WELDING ACCORDING TO THE REQUIREMENTS OF THE
"STRUCTURAL WELDING CODE" AWS D1.1-08. USE 70 KSI LOW-HYDROGEN
ELECTRODES.
F. PROVIDE NON-SHRINK NON-METALLIC GROUT UNDER BEAM BEARING PLATES
AND COLUMN BASE PLATES WITH A MINIMUM 28 DAY COMPRESSIVE
STRENGTH F'C = 7000 PSI.
G. PROVIDE STRUCTURAL STEEL THAT IS HOT DIPPED GALVANIZED TO ASTM
A123 GRADE Z350 WITH TOUCH UP ON ALL DAMAGED AREAS, INCLUDING
FIELD WELDS AT ALL EXTERIOR EXPOSED (INCLUDING IN EXTERIOR WALL
WYTHE’S) SHAPES, PLATES AND BOLTS.
H. PROVIDE STEEL LINTELS WITH A MINIMUM OF 8" BEARING PROPORTIONED AS
FOLLOWS FOR EACH 4" OF WALL WIDTH.
OPENING SIZE LINTEL
UP TO 4'-0" L 4 X 3-1/2 X 5/16
4'-1" TO 5'-0" L 5 X 3-1/2 X 5/16
5'-1" TO 6'-0" L 5 X 3-1/2 X 3/8
I. DO NOT FABRICATE STRUCTURAL STEEL PRIOR TO APPROVAL OF SHOP
DRAWINGS.
J. NO OPENINGS IN BEAMS OR COLUMNS ARE PERMITTED WITHOUT THE
APPROVAL OF THE COTR.
K. SPLICING OF STRUCTURAL STEEL MEMBERS WHERE NOT DETAILED ON THE
CONTRACT DOCUMENTS IS PROHIBITED WITHOUT PRIOR APPROVAL OF THE
COR AS TO LOCATION, TYPE OF SPLICE AND CONNECTION TO BE MADE.
L. PROVIDE STRUCTURAL STEEL SHOP DRAWINGS THAT HAVE BEEN PREPARED
UNDER THE SUPERVISION OF A REGISTERED PROFESSIONAL ENGINEER
REGISTERED IN PROJECT JURISDICTION. INCLUDE DETAILS FOR
APPLICATION AND ASSEMBLY OF ALL STRUCTURAL MEMBERS. INCLUDE
DETAILS OF CUTS, CONNECTIONS, HOLES, AND OTHER PERTINENT DATA.
INDICATE WELDS BY STANDARD AWS 2.1 SYMBOLS SHOWING SIZE, LENGTH
AND TYPE OF EACH WELD. SUBMITTED STRUCTURAL STEEL SHOP
DRAWINGS TO THE COR FOR APPROVAL.
M. WELD MISCELLANEOUS STEEL CONNECTIONS ALL AROUND WITH ONE-
QUARTER-INCH FILLET WELD UNLESS OTHERWISE NOTED, EXCEPT FOR
SLOTTED CONNECTIONS.
N. PROVIDE A MINIMUM BEARING LENGTH OF 6" FOR ALL BEAMS SUPPORTED
ON MASONRY.
O. THE CONTRACTOR SHALL NOT RELEASE BEAMS OR DIAGONAL BRACING
FROM HOISTING CABLES UNTIL ALL MEMBERS ARE SECURE WITH AT LEAST
(2) BOLTS. ALL FIELD WELDED CONNECTIONS SHALL BE COMPLETED
BEFORE RELEASING CABLES.
P. WHERE DOUBLE BEAM CONNECTIONS OCCUR ON EACH SIDE OF A COLUMN
WEB OR TO THE WEB OF A BEAM OVER A COLUMN, THERE MUST BE AT LEAST
ONE BOLT WITH A WRENCH-TIGHT NUT SECURING THE FIRST BEAM
CONNECTED AT ALL TIMES.
MASONRY
MANUFACTURE AND ERECT MASONRY IN ACCORDANCE WITH "BUILDING
CODE REQUIREMENTS FOR MASONRY STRUCTURES", (ACI 530/ASCE 5/TMS
402); AND "SPECIFICATIONS FOR MASONRY STRUCTURES", (ACI 530.1/ASCE
6/TMS 602).
Q. MASONRY INSPECTION FOR QUALITY ASSURANCE IS LEVEL B AS DEFINED IN
THE ACI-530.1 SPECIFICATIONS.
R. UNIT SPECIFICATIONS:
1. LOAD-BEARING, HOLLOW OR SOLID CMU: ASTM C- 90
2. MIN COMPR STRENGTH ON NET AREA = 1,900 PSI
3. SOLID CLAY OR SHALE FACING BRICK: ASTM C-216
4. MIN COMPR STRENGTH GROSS AREA TYPE "SW": = 3,000 PSI
5. MIN COMPR STRENGTH GROSS AREA TYPE "MW": = 2,500 PSI
6. USE TYPE "SW" WHERE UNITS ARE EXPOSED TO WEATHER OR ARE
BELOW GROUND SURFACE. OTHER AREAS SHALL BE UNITS TYPE "MW".
7. MORTAR TYPE "M" OR "N": ASTM C-270
8. USE TYPE "N" WHERE EXPOSED TO WEATHER AND TYPE M BELOW
GROUND SURFACE. ALL OTHER AREAS SHALL BE OF TYPE "M".
9. GROUT FOR BEAM BEARING AND COLUMN BASE PLATES:
a) NON-SHRINK NON METALLIC ASTM C-1107 GRADE "C", F'C = 5,000 PSI.
10. GROUT FOR FILLING CELLS OF MASONRY & BOND BEAMS:
a) ASTM C-476 COARSE, F'C = 2,500 PSI
S. DESIGN MINIMUM STRENGTH F’M=1500 PSI
T. BOND WYTHE’S OF CONCRETE MASONRY TOGETHER AT 16" VERTICALLY
(TWO BLOCK COURSES) USING CONTINUOUS HORIZONTAL WALL
REINFORCING.
U. PROVIDE TRUSS TYPE, BUTT WELDED SIDE AND WEB BARS OF GALVANIZED
W1.7 WIRES FOR CONTINUOUS HORIZONTAL WALL REINFORCING. PROVIDE
PREFABRICATED CORNERS AND TEES FOR WALL INTERSECTIONS. LAP 6" AT
SPLICES.
V. FILL MASONRY UNIT CELLS WITH COARSE GROUT WHERE CELLS CONTAIN
REINFORCEMENT.
W. PROVIDE ADEQUATE BRACING AND SUPPORT FOR MASONRY WORK UNTIL
PERMANENT CONSTRUCTION IS IN PLACE.
X. PROVIDE TWO (2) COURSES OF SOLID CMU PER ASTM C 90 OR GROUT-FILLED
CMU BENEATH ALL BEAM AND HEADER BEARING POINTS.
Y. ATTACH BRICK VENEER WITH TIES SPACED AT 24" O.C. HORIZONTALLY AND
16" O.C. VERTICALLY (MAXIMUM). CORRUGATED TIES ARE PROHIBITED FOR
WALLS WITH CAVITIES OVER 1". TIES SHALL EXTEND 3" INTO BRICK AND/OR
CMU.
HISTORIC MASONRY:
A. ALL EXISTING MASONRY ON THIS PROJECT IS HISTORIC, AND
WORK SHALL BE GOVERNED BY THE FOLLOWING DOCUMENTS:
1. THE SECRETARY OF THE INTERIOR’S STANDARDS FOR
REHABILITATION, NATIONAL PARK SERVICE.
2. GSA PRESERVATION NOTE 1, USE OF POWER TOOLS
FOR MORTAR REMOVAL.
3. GUIDELINES FOR REHABILITATING HISTORIC BUILDINGS:
MASONRY, NATIONAL PARK SERVICE.
4. PRESERVATION BRIEF #2, REPOINTING MORTAR JOINTS IN
HISTORIC MASONRY BUILDINGS, NATIONAL PARK SERVICE.
B. ANY BRICK OR STONE MASONRY NOTED TO BE REMOVED SHALL BE
CAREFULLY REMOVED TO AVOID DAMAGE AND CLEANED FOR
REUSE.
C. MORTAR SHALL MATCH THE PROPORTIONS OF CEMENT AND/OR LIME
DETERMINED BY PRE-CONSTRUCTION TESTING OF THE EXISTING
MORTAR. THE MORTAR SHALL MATCH THE COMPOSITION, COLOR,
TEXTURE, AND JOINT PROFILE OF THE EXISTING MORTAR.
D. PREPARE MASONRY MOCK UPS FOR COMPARISON AND APPROVAL
BY THE CONTRACTING OFFICER.
E. PERFORM MORTAR TESTING AND PREPARE MOCKUPS FOR EACH
DIFFERENT AREA AT EACH OF THE THREE (DOLLEY MADISON, COSMOS
CLUB, TAYLOE HOUSE) BUILDINGS.
F. STAINLESS STEEL HELICAL TIES SHALL BE SIMILAR TO “DRYFIX” BY
HELIFIX, INC. INSTALL TIES THROUGH MORTAR JOINT IN OUTER
WYTHE, RECESS OUTSIDE END OF TIE, AND FILL HOLE WITH
REPOINTING MORTAR PER MANUFACTURER’S INSTRUCTIONS AND
AT SPACING INDICATED.
G. PROVIDE ADEQUATE BRACING AND SUPPORT FOR MASONRY WORK
UNTIL PERMANENT CONSTRUCTION IS IN PLACE. TEMPORARY SHORING
AND/OR BRACING SHALL NOT BE FIXED OR IN DIRECT CONTACT WITH ANY
HISTORIC MATERIALS INCLUDING BUT NOT LIMITED TO MASONRY.
H. PROVIDE ADJUSTABLE MASONRY ANCHORS TO STEEL BEAMS AND
COLUMNS WHICH ARE EMBEDDED IN MASONRY AT 2'-0" O.C.
MAXIMUM.
I. CRACK INJECTION MATERIAL SHALL BE A MICROFINE, CEMENT-BASED
GROUT USING GRAVITY FEED WITH A COMPRESSIVE STRENGTH OF
2,500 TO 3,500 PSI. THE BASIS OF DESIGN PRODUCT IS
JAHN M30 #32 BY CATHEDRAL STONE PRODUCTS, INC. FOLLOW ALL
MANUFACTURER'S INSTRUCTIONS FOR PREPARATION AND INSTALLATION.
GENERAL
A. INFORMATION SHOWN REGARDING EXISTING CONDITIONS HAS BEEN
OBTAINED BY LIMITED VISUAL OBSERVATIONS AND FROM LIMITED EXISTING
DRAWINGS PROVIDED BY THE GOVERNMENT. AREAS NOT VISIBLE HAVE
BEEN ASSUMED TYPICAL WITH OBSERVED EXISTING CONDITIONS.
B. MEASURE AND PROVIDE ALL DIMENSIONS, ELEVATIONS AND CONDITIONS AT
THE JOB SITE PRIOR TO CONSTRUCTION AND THE SUBMISSION OF SHOP
DRAWINGS, AND NOTIFY THE COR IMMEDIATELY OF ANY DISCREPANCIES.
PROVIDE VERIFICATION AND NOTIFICATION AT LEAST TWO WEEKS PRIOR TO
THE START OF WORK SO THAT ANY NECESSARY CHANGES CAN BE MADE
WITHOUT DELAYING THE PROJECT SCHEDULE.
C. DETAILS, SECTIONS, AND NOTES SHOWN ON THESE DRAWINGS ARE
INTENDED TO BE TYPICAL AND APPLY TO SIMILAR CONDITIONS ELSEWHERE
UNLESS OTHERWISE SHOWN OR NOTED.
D. PROVIDE SHOP DRAWINGS SUBMITTED TO THE COR BEARING THE
CONTRACTOR'S STAMP, DATE AND SIGNATURE THAT VERIFIES THAT THE
DOCUMENTS HAVE BEEN REVIEWED AND CORRECTED FOR CONFORMANCE
TO AND COORDINATION WITH CONTRACT DOCUMENTS.
E. PROCEED WITH FABRICATION ONLY AFTER SHOP DRAWING APPROVAL BY
THE ENGINEER.
F. DO NOT REPRODUCE ANY PORTION OF CONTRACT DOCUMENTS IN THE SHOP
DRAWINGS.
G. SUBMIT INSPECTION REPORTS AND MATERIALS TESTING REPORTS TO THE
COR IN A TIMELY MANNER SUCH THAT CONSTRUCTION DELAY WILL BE
AVOIDED.
H. MEANS AND METHODS OF CONSTRUCTION ARE THE SOLE RESPONSIBILITY
OF THE CONTRACTOR.
I. PROVIDE TEMPORARY BRACING AND SHORING, AS REQUIRED, TO ENSURE
VERTICAL AND LATERAL STABILITY OF THE ENTIRE STRUCTURE OR PORTION
THEREOF DURING CONSTRUCTION.
J. WHERE THE CONTRACTOR IS REQUIRED TO ENGAGE A PROFESSIONAL
ENGINEER TO DESIGN AND SUBMIT CALCULATIONS, AND WHERE THE
PROFESSIONAL ENGINEER PREPARES THE CALCULATIONS USING A
COMPUTER SOFTWARE SYSTEM, USE SOFTWARE THAT IS READILY
AVAILABLE, INDUSTRY STANDARD FOR STRUCTURAL ENGINEERING IN
COMMON USE.
STRUCTURAL DEMOLITION
A. ALL MEANS AND METHODS OF REMOVING EXISTING CONSTRUCTION SHALL
BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
B. VERIFY ALL OPENING SIZES AND LOCATIONS WITH OTHER DISCIPLINES. THE
DRAWINGS DO NOT SHOW ALL OPENINGS REQUIRED. ADDITIONAL
OPENINGS, BLOCKOUTS AND SLEEVES MAY BE REQUIRED BY OTHER
DISCIPLINES AND SHALL BE CONSTRUCTED USING THE TYPICAL DETAILS
AND/OR THE CRITERIA INDICATED ON THE DRAWINGS. OPENINGS REQUIRED
BUT NOT SHOWN ON THE STRUCTURAL DRAWINGS MUST BE APPROVED BY
THE COR.
C. ALL NEW OPENINGS THROUGH EXISTING STRUCTURE SHALL BE LOCATED
AND MARKED. IF OPENING ARE THROUGH REINFORCED CONCRETE, FIND
AND MARK THE LOCATION OF THE REINFORCEMENT. DO NOT CUT OPENINGS
UNTIL APPROVED BY THE COR.
D. WHERE NEW OPENINGS IN EXISTING CONCRETE SLAB ARE TO BE CREATED,
CORE HOLES AT THE OUTSIDE CORNERS OF THE NEW OPENING PRIOR TO
DEMOLITION. SAW-CUT AND DEMOLISH SLAB ONLY AFTER THE INSTALLATION
OF ALL REQUIRED NEW STRUCTURAL FRAMING AND/OR REINFORCEMENT IN
PLAN OR SECTION, UNO. SAW CUT IN STRAIGHT LINES AND DO NOT EXTEND
INTO EXISTING SLAB TO REMAIN NOR BEYOND THE HOLES CORED AT THE
CORNERS OF THE NEW OPENING.
SHORING AND BRACING
A. ENGAGE A PROFESSIONAL STRUCTURAL ENGINEER REGISTERED IN THE
DISTRICT OF COLUMBIA TO PERFORM AN ENGINEERING SURVEY OF THE
BUILDING TO DETERMINE WHETHER REMOVING ANY ELEMENT COULD
RESULT IN A STRUCTURAL DEFICIENCY OR UNPLANNED COLLAPSE OF ANY
PORTION OF STRUCTURE OR ADJACENT STRUCTURES DURING DEMOLITION
OPERATIONS.
1. SUBMIT SURVEY A MINIMUM OF TWO WEEKS BEFORE SCHEDULED START
OF WORK OR EARLIER IF NECESSARY TO AVOID DELAYS.
2. SUBMIT WEEKLY SURVEY REPORTS FROM THE CONTRACTOR’S
PROFESSIONAL ENGINEER WHO IS RESPONSIBLE FOR SHORING AS THE
WORK PROGRESSES NOTING HAZARDS RESULTING FROM STRUCTURAL
DEMOLITION ACTIVITIES.
B. AT A MINIMUM, SHORE AND BRACE THE EXISTING STRUCTURE AS INDICATED
IN THE CONSTRUCTION DOCUMENTS AND AS NEEDED TO COMPLETE THE
WORK. INSTALL ADDITIONAL SHORING AND BRACING AS DETERMINED BY
THE CONTRACTOR’S PROFESSIONAL SHORING ENGINEER.
C. DESIGN TEMPORARY SHORING AND BRACING FOR SELF WEIGHT OF
STRUCTURE, CODE WIND LOADS, AND A MINIMUM CONSTRUCTION LOAD OF
100 PSF OR 3,000 LBS POINT LOAD OR ACTUAL LOAD WHICHEVER PRODUCES
GREATER STRESSES. USE DESIGN PROCEDURES THAT CONFORM TO ALL
GOVERNING CODES AND SAFETY REQUIREMENTS.
D. SHORE AND BRACE EXISTING STRUCTURE PRIOR TO DEMOLITION WORK AND
UNTIL PERMANENT NEW STRUCTURE OR REPAIRED EXISTING STRUCTURE
CAN SUPPORT LOADS.
E. SUBMIT SHORING DESIGN DRAWINGS SEALED BY A PROFESSIONAL
ENGINEER REGISTERED IN THE DISTRICT OF COLUMBIA. INDICATE ALL
POINTS OF SUPPORT TO EXISTING STRUCTURE, AND ANY LOADS APPLIED TO
EXISTING STRUCTURE TO REMAIN.
F. AFTER SHORING INSTALLATION, SUBMIT A LETTER REPORT FROM THE
CONTRACTOR’S SHORING ENGINEER THAT THEY HAVE VISITED THE SITE AND
DETERMINED THAT THE SHORING WAS INSTALLED IN ACCORDANCE WITH
THEIR DESIGN.
G. PROVIDE ADEQUATE TEMPORARY BRACING AND SUPPORT FOR ALL NEW
WORK INCLUDING BUT NOT LIMITED TO UNBRACED MASONRY WORK UNTIL
PERMANENT CONSTRUCTION IN PLACE.
H. MAINTAIN INTERIOR AND EXTERIOR SHORING, BRACING, AND STRUCTURAL
SUPPORTS TO PRESERVE STABILITY AND PREVENT MOVEMENT OR
COLLAPSE OF ANY PART OF STRUCTURE.
1. STRENGTHEN OR ADD NEW SUPPORTS WHEN REQUIRED DURING PROGRESS
OF DEMOLITION.
I. BRACING
1. BRACING: LOCATE BRACING TO CLEAR COLUMNS, FLOOR FRAMING
CONSTRUCTION, AND OTHER PERMANENT WORK. IF NECESSARY TO MOVE
BRACE, INSTALL NEW BRACING BEFORE REMOVING ORIGINAL BRACE.
I. DO NOT PLACE BRACING WHERE IT WILL BE CAST INTO OR INCLUDED
IN PERMANENT CONCRETE WORK UNLESS OTHERWISE APPROVED
BY THE COR.
II. INSTALL INTERNAL BRACING IF REQUIRED TO PREVENT SPREADING
OR DISTORTION OF BRACED FRAMES.
III. MAINTAIN BRACING UNTIL STRUCTURAL ELEMENTS ARE SUPPORTED
BY OTHER BRACING OR UNTIL PERMANENT CONSTRUCTION IS ABLE
TO WITHSTAND DESIGN LOADS.
TESTING AND INSPECTION:
RETAIN THE SERVICES TESTING AND INSPECTION AGENCY TO PERFORM THE
SERVICES SPECIFIED.
A. PROVIDE SERVICES ACCORDANCE WITH REQUIREMENTS OF THE DISTRICT
OF COLUMBIA AT A MINIMUM.
B. FAILURE TO RETAIN A TESTING AGENCY TO PROVIDE REQUIRED SERVICES
OR A FAILURE TO SUBMIT SIGNED AND SEALED REPORTS IS A NON-
COMPLIANCE WITH CONTRACT DOCUMENTS.
C. REMOVE AND REPLACE CONSTRUCTION CONSIDERED NON-COMPLIANT.
D. ALL TESTING AND INSPECTION SHALL BE UNDER THE DIRECTION OF A
PROFESSIONAL ENGINEER LICENSED TO PRACTICE IN THE LOCAL
JURISDICTION.
E. PROVIDE PRELIMINARY HANDWRITTEN SITE VISIT REPORTS CONFIRMING
VERBAL DISCUSSIONS TO THE CONTRACTOR REGARDING THE RESULTS OF
INSPECTIONS PRIOR TO LEAVING JOB SITE.
F. SUBMIT FINAL REPORTS TO THE COR IN A TIMELY MANNER, BUT NO LATER
THAN TEN (10) DAYS FOLLOWING INSPECTION OR TESTING UNDER THE NAME
AND SIGNATURE OF THE INSPECTOR AND LICENSURE SEAL AND SIGNATURE
OF THE PROFESSIONAL ENGINEER RESPONSIBLE FOR TESTING AND
INSPECTION.
G. PROVIDE INSPECTION FOR THE FOLLOWING AT A MINIMUM:
1. REINFORCING: LOCATION, ASTM DESIGNATION, BAR SIZES, TYPE,
QUANTITY, PLACEMENT, SPACING, AND CLEARANCES.
2. CONCRETE: ALL STRUCTURAL CONCRETE; LOCATION, STRENGTH, TYPE
(NORMAL OR LIGHTWEIGHT), SLUMP, PLACEMENT, AIR TEMPERATURE,
CURING AND WEATHER ACCOMMODATIONS AND CONCRETE ADDITIVES.
3. STRUCTURAL STEEL: LOCATION, ASTM DESIGNATION, MEMBER SIZES,
TYPE (PLAIN, PAINTED, GALVANIZED), PLACEMENT AND CONNECTIONS
INCLUDING WELDS AND BOLTS, POST-INSTALLED ANCHORS, ANCHOR
BOLTS AND GROUTING.
4. MASONRY: MASONRY INSPECTION FOR QUALITY ASSURANCE LEVEL B AS
DEFINED IN THE MASONRY SPECIFICATIONS AND INCLUDE INSPECTION
OF UNITS, GROUT, REINFORCING, ANCHOR BOLTS AND LINTELS AT A
MINIMUM. AS MASONRY CONSTRUCTION BEGINS, VERIFY THE
FOLLOWING ARE IN COMPLIANCE: PROPORTIONS OF SITE PREPARED
MORTAR, CONSTRUCTION OF MORTAR JOINTS, LOCATION OF
REINFORCEMENT AND CONNECTORS. PRIOR TO GROUTING, VERIFY THE
FOLLOWING ARE IN COMPLIANCE: GROUT SPACE, GRADE AND SIZE OF
REINFORCEMENT, PLACEMENT OF REINFORCEMENT, ANCHORS, TIES,
AND CONNECTORS, PROPORTIONS OF SITE PREPARED GROUT, AND
CONSTRUCTION OF MORTAR JOINTS. VERIFY PLACEMENT OF GROUT,
PREPARATION OF GROUT SPECIMENS, MORTAR SPECIMENS, AND/OR
PRISMS.
5. PROVIDE SPECIAL INSPECTION FOR MECHANICAL AND ADHESIVE
ANCHORS PER THE APPLICABLE BUILDING CODE AND PER THE CURRENT I
CC-ES REPORT (IBC TABLE 1705.3 NOTE B).
CHECKED BY
DRAWN BY
FLOOR NUMBER
SHEET TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
PROJECT NUMBER
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NUMBER
CITY/ST./ZIP
ADDRESS
BUILDING NAME
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
24 X 36
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N T
R A
C T
O R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
T A
M P
O R
S E
A L
D E
S
IG
N E
R
ID
E N
T
IF
IC
A
T
IO
N O
W N
E R
ID
E
N T
IF
IC
A T
IO
N
SHEET OF SHEETS
DOLLEY MADISON
717 MADISON PLACE NW
WASHINGTON, DC 20005
PRESERVATION AND MINOR REHABILITATION
47PF0019D0048
architrave p.c. architects
McMullan & Associates
DC0111ZZ, DC0112ZZ, DC0113ZZ
Historic Townhouses Envelope Repairs_Madison_Structural_R22
BRIAN KEEFER
RDC04752, RDC04736, RDC04732
STRUCTURAL
/2
/2
:1 :5
P
M
S-001
DESIGN NOTES
HISTORIC TOWNHOUSES ENVELOPE REPAIRS -
MADISON
FINAL CD SUBMISSION (100%)
1/24/25
09/10/2024AA/SO
CN
GENERAL SERVICES
ADMINISTRATION
MADISON HOUSE, COSMOS CLUB,
& TAYLOE HOUSE
707 MADISON PLACE, NW
WASHINGTON, DC 20005-7700
PROPERTY OF THE UNITED STATES GOVERNMENT This is controlled unclassified information. Do not remove the CUI marking. Properly destroy or return documents when no longer needed.
Mark Date Description
1/23/25
2 45
S-201
DOLLEY
MADISON
COSMOS TAYLOE
COURTYARD
RAISED
PATIO
STRUCTURAL WORK AREA
ARCADE AND BREEZEWAY
MARKEY BUILDING
1/8"=1'-0"
4' 8' 16'
1/8"=1'-0"
4' 8' 16'
CHECKED BY
DRAWN BY
FLOOR NUMBER
SHEET TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
PROJECT NUMBER
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NUMBER
CITY/ST./ZIP
ADDRESS
BUILDING NAME
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
24 X 36
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N T
R A
C T
O R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
T A
M P
O R
S E
A L
D E
S
IG
N E
R
ID
E N
T
IF
IC
A
T
IO
N O
W N
E R
ID
E
N T
IF
IC
A T
IO
N
SHEET OF SHEETS
DOLLEY MADISON
717 MADISON PLACE NW
WASHINGTON, DC 20005
PRESERVATION AND MINOR REHABILITATION
47PF0019D0048
architrave p.c. architects
McMullan & Associates
DC0111ZZ, DC0112ZZ, DC0113ZZ
Historic Townhouses Envelope Repairs_Madison_Structural_R22
BRIAN KEEFER
RDC04752, RDC04736, RDC04732
STRUCTURAL
/2
/2
:1 :5
P
M
S-101
OVERALL FIRST FLOOR PLAN
HISTORIC TOWNHOUSES ENVELOPE REPAIRS -
MADISON
FINAL CD SUBMISSION (100%)
1/24/25
09/10/2024AA
CN
GENERAL SERVICES
ADMINISTRATION
MADISON HOUSE, COSMOS CLUB,
& TAYLOE HOUSE
707 MADISON PLACE, NW
WASHINGTON, DC 20005-7700
PROPERTY OF THE UNITED STATES GOVERNMENT This is controlled unclassified information. Do not remove the CUI marking. Properly destroy or return documents when no longer needed.
1/8" = 1'-0"S-101 S-101
1 OVERALL FIRST FLOOR PLAN
Mark Date Description
MADISON COSMOS TAYLOE
1/23/25
4 45
Pamela Patrick Rectangle
Pamela Patrick Callout
DOLLEY MADISON HOUSE EXTENTS
S-202
DOLLEY MADISON COSMOS TAYLOE
STRUCTURAL WORK AREA
MADISON COSMOS TAYLOE
1/8"=1'-0"
4' 8' 16'
1/8"=1'-0"
4' 8' 16'
CHECKED BY
DRAWN BY
FLOOR NUMBER
SHEET TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
PROJECT NUMBER
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NUMBER
CITY/ST./ZIP
ADDRESS
BUILDING NAME
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
24 X 36
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N T
R A
C T
O R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
T A
M P
O R
S E
A L
D E
S
IG
N E
R
ID
E N
T
IF
IC
A
T
IO
N O
W N
E R
ID
E
N T
IF
IC
A T
IO
N
SHEET OF SHEETS
DOLLEY MADISON
717 MADISON PLACE NW
WASHINGTON, DC 20005
PRESERVATION AND MINOR REHABILITATION
47PF0019D0048
architrave p.c. architects
McMullan & Associates
DC0111ZZ, DC0112ZZ, DC0113ZZ
Historic Townhouses Envelope Repairs_Madison_Structural_R22
BRIAN KEEFER
RDC04752, RDC04736, RDC04732
STRUCTURAL
/2
/2
:1 :5
P
M
S-102
OVERALL ROOF LEVEL PLAN
HISTORIC TOWNHOUSES ENVELOPE REPAIRS -
MADISON
FINAL CD SUBMISSION (100%)
1/24/25
09/10/2024AA
CN
GENERAL SERVICES
ADMINISTRATION
MADISON HOUSE, COSMOS CLUB,
& TAYLOE HOUSE
707 MADISON PLACE, NW
WASHINGTON, DC 20005-7700
PROPERTY OF THE UNITED STATES GOVERNMENT This is controlled unclassified information. Do not remove the CUI marking. Properly destroy or return documents when no longer needed.
1/8" = 1'-0"S-102 S-102
1 OVERALL ROOF PLAN
Mark Date Description
1/23/25
5 45
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Line
Pamela Patrick Rectangle
Pamela Patrick Callout
DOLLEY MADISON HOUSE EXTENTS
DRAWING ABBREVIATIONS GENERAL NOTES
LEGEND
PROJECT INFORMATION
- PROJECT NAME: HISTORIC TOWNHOUSES ENVELOPE
REPAIRS
- ADDRESS: 717 MADISON PLACE, NW DC 20005-7700
APPLICABLE CODES
- PBS P100 October 2021
- PBS P120, Public Buildings Service Cost and Schedule Management Policy Requirements
- Secretary of the Interior's Standards for the Treatment of Historic Properties
- ADM 1022.3 GSA Procedures for Historic Properties
- 2021 International Building Code Council (IBC)
- 2021 International Existing Building Code (IEBC)
- 2021 NFPA Life Safety Code (NPFA 101)
- 2021 International Fire Code (IFC)
- 2021 International Plumbing Code (IPC)
- 2021 ICC Codes
- 2020 National Electrical Code NFPA 70
- 2015 ABAAS (Architectural Barriers Act - Accessibility Standards)
BUILDING PLANNING
OCCUPANCY: GROUP B, GROUP S1,
GROUP U
MIXED OCCUPANCY? YES
REQUIRED FIRE SEPARATION: 6"
TYPE OF CONSTRUCTION
CONSTRUCTION TYPE: TYPE 1B
GENERAL BUILDING LIMITATIONS
- PENTHOUSE AND ROOF STRUCTURE: YES
FIRE PROTECTION SYSTEMS
- FIRE EXTINGUISHING SYSTEM:
YES
- STANDPIPE SYSTEM: NO
- SMOKE CONTROL: NO
CLASS: 1
- SPRINKLER SYSTEM: YES
ESSENTIAL FACILITY
(CHAPTER 16, IBC)
ESSENTIAL FACILITY? NO
SITE SUMMARY
A ---------------------
A/E ARCHITECT/ENGINEER
ABA ARCHITECTURAL BARRIERS ACT
ACM ASBESTOS-CONTAINING
MATERIALS
ADA AMERICANS WITH DISABILITIES
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AHU AIR HANDLING UNIT
ALT ALTERNATE
AL ALUMINUM
APC ACOUSTICAL PANEL CEILING
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
ASSY ASSEMBLY
AVG AVERAGE
AW ARCHITECTURAL WOODWORK
B ---------------------
BB BASEBOARD
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BOT BOTTOM
BRKT BRACKET
BRK BRICK
BRZ BRONZE/BRASS
BTWN BETWEEN
C ---------------------
C COSMOS CLUB
C CONC CAST CONCRETE
CAB CABINET
CAV CAVITY
CD CONSTRUCTION DOCUMENTS
CFLG COUNTERFLASHING
CI CAST IRON
CIP CAST-IN-PLACE
CL CENTER LINE
CLG CEILING
CLG HT CEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR COLOR
CM CASEMENT MULTIPANED
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
COORD COORDINATE
CPT CARPET
CS CAST STONE
CSWK CASEWORK
CTR CENTER
D ---------------------
D DOOR
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DH DOUBLE HUNG
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DN DOWN
DOC DOCUMENT
DPI DOUBLE PANE INSULATED
DR DUTCHMAN REPAIR
DS DOWNSPOUT
E ---------------------
EA EACH
ES EACH SIDE
EL ELEVATION
ELEV ELEVATOR
ENTR ENTRANCE
EPXY EPOXY REPAIR
EQ EQUAL
ETR EXISTING TO REMAIN
EXIST EXISTING
EXT EXTERIOR
F ---------------------
FA FIRE ALARM
FAS BD FASCIA BOARD
FD FIXED - DOUBLE GLAZING
FDTN FOUNDATION
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF INSUL FOIL BACKED INSULATION
FGL FIBERGLASS
FHP FULL HEIGHT PARTITION
FIN FINISH
FIXT FIXTURE
FLEX FLEXIBLE
FLG FLOORING
FLT FELT WEATHERSTRIPPING
FLMT FLUSH MOUNT
1. DO NOT SCALE DRAWINGS.
2. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO COMMENCING WORK.
3. ALL WORK ON THIS PROJECT SHALL BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES AND
REGULATIONS.
4. THE DRAWINGS HAVE BEEN DEVELOPED THROUGH USE OF EXISTING BUILDING DRAWINGS AND FIELD
OBSERVATION. BEFORE STARTING WORK, REVIEW EXISTING BUILDING CONDITIONS, AND DRAWINGS.
IMMEDIATELY BRING ANY CONDITION CHANGE OR INFORMATION FOUND TO BE DIFFERENT THAN SHOWN TO
THE ATTENTION OF THE COR.
5. DO NOT STACK MATERIALS IN SUCH A MANNER THAT WOULD CREATE CONCENTRATED LOADS.
6. FULLY COORDINATE ALL WORK BETWEEN TRADES AND SUBCONTRACTORS.
7. MAINTAIN EGRESS PATHS THROUGH BUILDING AT ALL TIMES THE BUILDING IS OCCUPIED.
8. PERFORM NO ON-SITE DEMOLITION WORK UNTIL ALL SUBMITTALS PERTINANT TO THE ITEMS TO BE
DEMOLISHED HAS BEEN SUBMITTED AND APPROVED.
9. IT IS NOT EXPECTED THAT HAZARDOUS MATERIALS BEYOND THOSE IDENTIFIED IN THIS SET WILL BE
ENCOUNTERED IN THE WORK. IF MATERIALS SUSPECTED OF CONTAINED HAZARDOUS MATERIALS ARE
ENCOUNTERED DURING THE WORK, STOP WORK IMMEDIATELY AND NOTIFY COR.
10. REFER TO THE HAZARDOUS MATERIALS NOTES ON COVER SHEET, G-001, TO IDENTIFY ALL DEMOLITION
WORK INVOLVING HANDLING HAZARDOUS MATERIALS
11. COORDINATE LAYDOWN AND STAGING AREAS WITH COR.
A. DISMANTLE: DISASSEMBLE OR DETACH A HISTORIC ITEM FROM A SURFACE OR A NONHISTORIC ITEM FROM A HISTORIC SURFACE; USING GENTLE METHODS AND EQUIPMENT TO PREVENT DAMAGE TO HISTORIC ITEMS
AND SURFACES; DISPOSE OF ITEMS UNLESS INDICATED TO BE SALVAGED OR REINSTALLED.
B. EXISTING TO REMAIN: EXISTING ITEMS THAT ARE NOT TO BE REMOVED OR DISMANTLED; EXCEPT TO THE
DEGREE INDICATED FOR PERFORMING REQUIRED WORK.
C. REMOVE: TAKE DOWN OR DETACH A NONHISTORIC FINISH OR ITEM LOCATED WITHIN A HISTORIC SPACE AREA OR ROOM, USING METHODS AND EQUIPMENT TO PREVENT DAMAGE TO HISTORIC ITEMS AND SURFACES;
DISPOSING OF ITEMS UNLESS INDICATED TO BE SALVAGED OR REINSTALLED.
D. REINSTALL: PROTECT REMOVED OR DISMANTLED ITEMS AND ASSEMBLE AND ERECT, COMPLETE AND READY
FOR INTENDED USE
E. RETAIN: KEEP AN ELEMENT OR DETAIL SECURE AND INTACT.
F. SALVAGE: PROTECT REMOVED OR DIMANTLED ITEMS AND DELIVER THEM TO THE GOVERMENT.
G. FURNISH: SUPPLY, DELIVER TO PROJECT SITE, AND UNLOAD.
H. INSTALL: UNLOAD, ASSEMBLE, AND ERECT, COMPLETE AND READY FOR THE INTENDED USE.
I. PROVIDE: FURNISH AND INSTALL, COMPLETE IN PLACE AND READY FOR FULL USE.
J. RECYCLE: DETACH ITEM FROM EXISTING CONSTRUCTION AND DISPOSE OF IT AT APPROVED COLLECTION
SITE. DO NOT REUSE ON-SITE UNLESS SPECIFICALLY DIRECTED TO DO SO.
DRAWING SYMBOLS
INTERIOR ELEVATION
MARK
DETAIL NUMBER
EXTERIOR ELEVATION MARK
DETAIL PLAN MARK
DRAWING FROM
SHEET NUMBER WHERE
ELEVATION / DETAIL IS
DRAWN
SHEET NUMBER WHERE
ELEVATION / DETAIL IS
DRAWN
SHEET NUMBER WHERE
SECTION / DETAIL IS
DRAWN
DRAWING
TO
NORTH
ARROW
A101
DETAIL NUMBER
A101
DETAIL NUMBER
SECTION MARK
A-101
1 DETAIL NUMBER
LIMITS OF
WORK
A-102A-108
DEFINITIONS
FLR FLOOR
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FRMG FRAMING
FS FIXED - SINGLE PANE
FT FEET
G ---------------------
GFCI GOVERNMENT FURNISHED
CONTRACTOR
INSTALLED
GFGI GOVERNMENT FURNISHED
GOVERMENT INSTALLED
GFRG GLASS-FIBER-REINFORCED
GYPSUM
GLZ GLAZING
GMF GALVANIZED METAL FIN
WEATHERSTRIPPING
GR FL GROUND FLOOR
GS GALVANIZED METAL
GYP BD GYPSUM BOARD
H ---------------------
HDW HARDWARE
HDWD HARDWOOD
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HT HEIGHT
I ---------------------
IBC INTERNATIONAL BUILDING
CODE
INSUL INSULATION
INT INTERIOR
J ---------------------
JAN JANITOR
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
KO CONTRACTING OFFICER
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBP LEAD-BASED PAINT
LBS POUNDS
LCC LEAD COATED COPPER
LF LINEAR FEET (FOOT)
LIN LINEAR
LVR LOUVER
M ---------------------
M DOLLEY MADISON HOUSE
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MEMB MEMBRANE
MFR MANUFACTURER
MGMT MANAGEMENT
MID MIDDLE
MIN MINIMUM, MINUTE
MISC MISCELLANEOUS
MO MASONRY OPENING
MTL METAL
N ---------------------
N NORTH
NA NOT APPLICABLE
NAR NO ANTICIPATED REPAIR
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL OPENING
NP NO PAINT
NTS NOT TO SCALE
O -------------------
OC ON CENTER
OFD OVERFLOW DRAIN
OFF OFFICE
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P --------------------
PCC PRECAST CONCRETE
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PLG PILING
PLYWD PLYWOOD
PNL PANEL
PR PAIR
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTN PARTITION
PWR POWER
Q --------------------
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBR RUBBER
RCP REFLECTED CEILING PLAN
RCR REMOVE, REPAIR, CLEAN,
REINSTALL
RD ROOF DRAIN (WITH INTERIOR
STORM DRAIN LINE)
RE REMOVE EXISTING PAINT (NO
LEAD)
REF REFERENCE
REP REPAIR
REPL REPLACE
REINS REINSTALL
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RG RUBBER GASKET
WEATHERSTRIPPING
RGZ REGLAZE WINDOW GLASS TO
SASH
RLG RAILING
RM CORRUGATED/RIBBED METAL
WEATHERSTRIPPING
RP REPAINT
RPME REPLACE PIECE TO MATCH
EXISTING
RRR REMOVE, CLEAN, REINSTALL
S --------------------
S SCUPPER
SBS STYRENE BUTADIEN STYRENE
SCHED SCHEDULE
SDS SCUPPER AND DOWNSPOUT
SF SQUARE FOOT (FEET)
SGL SINGLE
SHT MTL FLASH SHEET METAL
(FLASHING)
SH SINGLE HUNG
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SLT SEALANT
WEATHERSTRIPPING
SMK SMOKE
SP SPRING FORMED METAL
WEATHERSTRIPPING
SP EL SPOT ELEVATION
SPC SINGLE PANE COLORED
GLAZING
SPLG SINGLE PANE LEADED
GLAZING
SPT SINGLE PANE TRANSPARENT
GLAZING
SPTR SINGLE PANE OPAQUE /
OBSCURED / TEXTURE GLAZING
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SST STAINLESS STEEL
ST STAIRS
STC STORAGE CLOSET
STG STORAGE
STR STAIR
SW SIDEWALK
T --------------------
T TAYLOE HOUSE
TCSS TERNE COAT STAINLESS
STEEL
TD TRENCH DRAIN
TEMP TEMPORARY
TFF TOP OF FINISH FLOOR
THK THICKNESS
TLT TOILET
TOM TOP OF MASONRY
TOS TOP OF SLAB
TRANS TRANSOM
TRTD TREATED
TS THRU-WALL SCUPPER
V --------------------
V VENT
VEST VESTIBULE
VIF VERIFY IN FIELD
W --------------------
W WINDOW
WD WOOD
Y --------------------
YDS YARDS
CW101 WINDOW TAG
OUT OF SCOPE
EXISTING WALLS
REMOVE AND REINSTALL
STEEL PICKET FENCE
CDB01 DOOR TAG
EGRESS PATH
DISMANTLE AND REMOVE
MATERIAL LEGEND
STUCCO
MORTAR
INSULATION
LIMESTONE
BRICK - ELEVATION
BRICK - SECTION
MDS01 DOWNSPOUT TAG
CONTRACTOR LAYDOWN
PROPETY LINE
CMU
ROOF TYPER-#
WOOD
CHECKED BY
DRAWN BY
FLOOR NUMBER
SHEET TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
PROJECT NUMBER
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NUMBER
CITY/ST./ZIP
ADDRESS
BUILDING NAME
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
24 X 36
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N T
R A
C T
O R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
T A
M P
O R
S E
A L
D E
S
IG
N E
R
ID
E N
T
IF
IC
A
T
IO
N O
W N
E R
ID
E
N T
IF
IC
A T
IO
N
SHEET OF SHEETS
architrave p.c. architects
420 10th ST. S.E.
Washington D.C. 20003
202-544-1640
/2
/2
:1 :3
P
M
A-001
NOTES & ABBREVIATIONS
HISTORIC TOWNHOUSES ENVELOPE REPAIRS
FINAL CD SUBMISSION (100%)
1/24/25
07/21/23TS
RLS,MR
RDC04752, RDC04736, RDC04732
GENERAL SERVICES
ADMINISTRATION
MADISON HOUSE, COSMOS CLUB,
& TAYLOE HOUSE
717 MADISON PLACE, NW
WASHINGTON, DC 20005-7700
DC0111ZZ_B1-03_A_22
47PF0019D0048
architrave p.c. architects
McMullan & Associates
DC0111ZZ, DC0112ZZ, DC0113ZZ
MADISON HOUSE, COSMOS CLUB, & TAYLOE HOUSE
717 MADISON PLACE NW
WASHINGTON, DC 20005
PRESERVATION AND MINOR REHABILITATION
BRIAN KEEFER
N/A
ARCHITECTURAL
PROPERTY OF THE UNITED STATES GOVERNMENT This is controlled unclassified information. Do not remove the CUI marking. Properly destroy or return documents when no longer needed.
Mark Date Description
12 45
PULLEY SASH CHORD, 2 SASH LIFTS, 1 THUMB LOCK1
HARDWARE SETS:
PULLEY SASH CORD, 2 SASH LIFTS, 2 THUMB LOCKS2
PULLEY WITH CHAIN, 2 SASH LIFTS, 1 THUMB LOCK3
PULLEY WITH CHAIN, 2 SASH LIFTS AND 2 THUMB LOCKS
SPRING LOADED METAL TAPE, 2 SASH LIFTS AND 2 THUMB LOCKS
SPRING LOADED METAL TAPE, 2 THUMB LOCKS
HINGES, CASEMENT LATCH, RIM BOLT
DOOR - HINGES, CREMONE SET
DOOR - 3, 4.5" HINGES; 1 KNOB, 2 BOLTS
CHAIN AND PULLEY, 2 THUMBLOCKS AND NO LIFTS
SPRING LOADED METAL TAPE, NO SASH LIFT, NO
THUMB LOCK
CHAIN AND PULLEY, 1 THUMB LOCK, NO LIFTS
13 CHAIN AND PULLEY, 1 THUMBLOCK, 1 LIFT
LINTEL
STOOL
UPPER SASH
MUNTINS
DOUBLE HUNG WINDOW DIAGRAM
CASING
LOWER SASH
APRON
EXTERIOR INTERIOR
BRICK
MOLD
MEETING RAIL
SILL
LUG
MULLIONS
CW101
BUILDING
FENESTRATION TYPE
FLOOR LEVEL
FENESTRATION NUMBER
FENESTRATION
NUMBERING EXAMPLE:
CDB01
BUILDING
FENESTRATION TYPE
FLOOR LEVEL
FENESTRATION NUMBER
BUILDING
DOWNSPOUT
DOWNSPOUT NUMBER
MDS01
CHECKED BY
DRAWN BY
FLOOR NUMBER
SHEET TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
PROJECT NUMBER
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NUMBER
CITY/ST./ZIP
ADDRESS
BUILDING NAME
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
24 X 36
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N T
R A
C T
O R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
T A
M P
O R
S E
A L
D E
S
IG
N E
R
ID
E N
T
IF
IC
A
T
IO
N O
W N
E R
ID
E
N T
IF
IC
A T
IO
N
SHEET OF SHEETS
architrave p.c. architects
420 10th ST. S.E.
Washington D.C. 20003
202-544-1640
/2
/2
:1 :3
P
M
A-002
KEY TO SCHEDULES
HISTORIC TOWNHOUSES ENVELOPE REPAIRS
FINAL CD SUBMISSION (100%)
1/24/25
01/11/24NN
MR
RDC04752, RDC04736, RDC04732
GENERAL SERVICES
ADMINISTRATION
MADISON HOUSE, COSMOS CLUB,
& TAYLOE HOUSE
717 MADISON PLACE, NW
WASHINGTON, DC 20005-7700
DC0111ZZ_B1-03_A_22
47PF0019D0048
47PM0122F0003
architrave p.c. architects
McMullan & Associates
DC0111ZZ, DC0112ZZ, DC0113ZZ
MADISON HOUSE, COSMOS CLUB, & TAYLOE HOUSE
717 MADISON PLACE NW
WASHINGTON, DC 20005
PRESERVATION AND MINOR REHABILITATION
BRIAN KEEFER
N/A
ARCHITECTURAL
0201 DISMANTLE RUBBERIZED TRANSITION THRESHOLD TO RAISED PATIO
0202 DISMANTLE EXIST. TERNE COAT STAINLESS STEEL COPING
0203 REMOVE AND REINSTALL EXIST ROOF DRAIN COVER
0204 DISMANTLE AND SALVAGE WALL BRICKS
0206 DISMANTLE AND SALVAGE BRICK PAVERS
0206A REMOVE PRECAST CONCRETE PAVERS FOR REINSTALLATION
0207 ABATE ACM ON GYPSUM BOARD CEILING. DISMANTLE GYPSUM BOARD CEILING THROUGHOUT THE
FIFTH FLOOR
0207A DISMANTLE METAL LATH AND PLASTER CEILINGS BETWEEN THE (REMOVED) GYPSUM BOARD CEILING AND THE TERRA COTTA ROOFING SYSTEM ALONG THE NORTH AND SOUTH WALLS AND AT
THE BEAM LOCATIONS ON THE WEST WALL TO ACCOMMODATE STRUCTURAL WORK
0208 DISMANTLE BRICK PARAPET AND PRECAST CONCRETE/LIMESTONE COPING. SEE 1/S202 DRAWINGS
FOR EXTENT OF WORK. SALVAGE BRICK AND COPING FOR REINSTALLATION
0208A DISMANTLE LIMESTONE BALLUSTRADE AND COPING STONES. SEE 1/S202 DRAWINGS FOR EXTENT
OF WORK. SALVAGE LIMESTONE FOR REUSE
0208B DISMANTLE LIMESTONE CORNICE. SEE a/S202 DRAWINGS FOR EXTENT OF WORK. SALVAGE
LIMESTONE FOR REINSTALLATION
0209 REMOVE PRECAST CONCRETE CHIMNEY CAPS
0211 DISMANTLE AND SALVAGE GRANITE PAVERS FOR REINSTALLATION
0213 REMOVE COUNTERFLASHING AND FASTENERS
0214 DISMANTLE CEMENT BASED STUCCO WITH LBP ENCAPSULATED IN THE STUCCO LAYERS AND
PROVIDE ACCESS AND TWO WEEKS TIME FOR COR TO EVALUATE CONDITION OF MASONRY
0215 REMOVE SBS ROOFING TO SUBSTRATE INCLUDING FLASHING
0217 DISMANTLE PRECAST STONE THRESHOLD
0218 DISMANTLE WROUGHT IRON BALCONY, ABATE LBP, RESTORE OFF-SITE (WIR-2), AND REINSTALL TO
MATCH EXISTING CONDITIONS
0219 ABATE LBP FROM BRICK - FULL FACADE
0219A ABATE LBP FROM CAST IRON SURFACES ON CORNICE AND BRACKETS
0219B ABATE LBP FROM METAL SURFACES ON CORNICE AND BRACKETS, COPING, GUTTERS, AND
DOWNSPOUT CONDUCTOR HEADS
0221 DISMANTLE/ABATE LBP SHUTTERS ON ALL WINDOWS AND DOORS
0222 ABATE LBP FROM WOOD TRIM ALL EXPOSED SIDES
0223 ABATE LBP FROM WOOD LOUVERED VENT, TRIM WORK AND PEDIMENT
0224 ABATE LBP FROM EXTERIOR WOOD CEILING
DEMOLITION
WORK CODES
MASONRY
0401 REINSTALL PARAPETS USING SALVAGED BRICK AND PARAPET CAPS
0401A REINSTALL BALLUSTRADE AND COPING STONES WITH SALVAGED LIMESTONE MATERIAL. SEE
2/S202 DWGS FOR EXTENT OF WORK
0401B REINSTALL CORNICE AND SOFFIT WITH SALVAGED LIMESTONE
0402 REINSTALL BRICK PAVERS SALVAGED MATERIAL TO CREATE AN ABA COMPLIANT THRESHOLD
0403 REPAIR BRICK
0404 REMOVE AND REINSTALL OUTER WYTHE OF BRICK - SEE 6/S501
0405 REINSTALL GRANITE PAVERS SALVAGED MATERIAL TO CREATE AN ABA-COMPLIANT THRESHOLD
AND RAMP
0406 REPLACE MISSING BRACKET ON CORNICE SOFFIT. CREATE REPLICA OF ADJACENT BRACKETS.
0407 REPAIR MASONRY AT CONNECTION WITH WROUGHT IRON BALCONY
0408 PATCH LIMESTONE BALUSTER WITH CRACK
0409 REPOINT BRICK FROM CORNER TO CORNER EDGE TO EDGE
0410 REPOINT MORTAR ON GRANITE STAIR
0412 REINSTALL SALVAGED WALL BRICK
METALS
0502 RESTORE WROUGHT IRON BALCONY, REMOVE TOP RAILS AND PROVIDE NEW TOP RAILS TO
MATCH EXISTING IN PROFILE, DIMENSIONS, AND COMPOSITION. PROVIDE FULLY WELDED
JOINTS. REPLACE OTHER PIECES TOO CORRODED TO REPAIR.
0503 ROUTE NEW LEAD-COATED COPPER OUTLET TUBE THROUGH EXISTING GUTTER, PROVIDE
NEW DOWNSPOUT AND SPLASH GUARD. SEE DETAIL 3/A-506.
0506 PROVIDE TIN/ZINC COATED COPPER COPING
WOOD AND PLASTICS
0601 CONSERVE WOOD PANEL TO REPAIR CRACK IN PANEL
0602 REPAIR FULL LENGTH OF FASCIA ALONG EXIST. GUTTER.
0603 PRESERVE WOOD TRIM AND ARCHITECTURAL ELEMENTS ON DORMERS (6 TYP). USE EPOXY
FILLERS FOR DETERIORATED AREA LESS THAN 4 CUBIC INCHES (CI), DUTCHMAN REPAIRS
FOR DETERIORATED AREAS BETWEEN 4 CI AND 12 CI. REPLACE WOOD MOUNDING/TRIM FOR
PIECES OVER 50% DETERIORATED.
THERMAL AND MOISTURE PROTECTION
0701 PROVIDE SLATE SHINGLES TO MATCH EXISTING TYPE AND SIZE FOR EACH BUILDING
WHERE MISSING, CHIPPED, OR BROKEN. ASSUME 10% REPLACEMENT. SEE DETAIL 3/A-505.
0702 SECURE LOOSE SLATE SHINGLES ON MAIN AND DORMER ROOFS WITH STAINLESS STEEL
SLATE HOOK. ASSUME 10% REATTACHMENT. SEE DETAIL ON 3/A-505
0703 REMOVE CANVAS AWNING AND STEEL SUPPORT FRAMING AT RAISED PATIO. REINSTALL
AT COMPLETION OF WORK IN THE AREA.
0704 NOT USED
0705 PROVIDE COPPER FLASHING TO MATCH FLASHING MATERIAL REMOVED
0706 ENSURE FUNCTIONAL DRAINAGE SYSTEM. 1. BEFORE CONSTRUCTION REMOVE
BLOCKAGES IN CONNECTOR HEADS, AND ALONG EIGHT FEET OF UNDERGOUND/LATERAL
STORM DRAIN LINES. REMOVE BLOCKAGES IN INTERIOR DRAIN LINES FROM COSMOS
ROOF TO LATERAL STORM DRAIN PIPELINES AT THE BASEMENT SLAB. 2. BEFORE
CONSTRUCTION - VIDEO AND DOCUMENT CONDITIONS OF CONNECTOR HEADS,
DOWNSPOUTS, AND UNDERGROUND LINES AND SUBMIT GRAPHIC AND WRITTEN ANALYSIS
OF FINDINGS ALONG WITH RECOMMENDATIONS FOR DOWNSPOUTS TO BE
REPAIRED/REINSTALLED, OR PROVIDED NEW. 3. DURING CONSTRUCTION PROTECT ROOF
DRAINAGE SYSTEM PIPING. AVOID CLOGGING WITH DIRT OR DEBRIS. 4. UPON
COMPLETION OF CONSTRUCTION MATCH THE PRECONSTRUCTION CONDITIONS OF THE
ROOF DRAINAGE SYSTEM. MAKING SURE ALL DOWNSPOUTS, CONDUCTOR HEADS,
CLEANOUTS, AND UNDERGROUND/ LATERAL LINES ARE UNOBSTRUCTED. RESCOPE AND
REMOVE BLOCKAGES AS NECESSARY.
0706A REMOVE DOWNSPOUT(S) FOR LBP ABATEMENT, STUCCO WORK (WHERE SPECIFIED),
REPOINTING, AND PAINTING. PROVIDE TEMPORARY WATER DRAINAGE SYSTEM DURING
WORK. REINSTALL REPAIRED DOWNSPOUT
0706B PROVIDE CLEANOUT AT THE GRADE
0706C PROVIDE CLEANOUTS (2) ON RAISED PATIO AT TRANSITION FROM DOWNSPOUT TO
UNDERGROUND STORM LINE
0706D REMOVE RETANGULAR DOWNSPOUT. PROVIDE TEMPORARY WATER DRAINAGE SYSTEM
DURING WORK. PROVIDE ROUND DOWNSPOUT TIN/ZINC COATED COPPER SIZED TO
HANDLE DRAINAGE FROM BRANCH LINES. CONNECT BRANCH LINES TO NEW DOWNSPOUT.
ENSURE A FUNCTIONAL DRAINAGE FLOW. PAINT TO MATCH WALL COLOR.
0706F PROVIDE CLEANOUT ON LATERAL DOWNSPOUT LINE BEFORE IT ENTERS THE BUILDING
0706G RETAIN CONDUCTOR HEAD. CHECK FOR AND REPAIR ANY OPEN JOINTS/HOLES. REMOVE
LBP PAINT, PRIME, AND PAINT.
0706H PROVIDE OVERFLOW SPLASH GUARD ON GUTTER. SEE DETAIL 8/A505.
0706I RETAIN SCUPPER, CONDUCTOR HEAD AND DOWNSPOUT.
0706J REMOVE EXISTING ROOF DRAIN BODY AND DOME
0706K PROVIDE CAST IRON ROOF DRAIN. TIE INTO EXISTING STORM DRAIN LINES AS PART OF
THE INSTALLATION OF NEW MEMBRANE ROOFING.
0706L PROVIDE OVERFLOW THRU-WALL SCUPPER. SEE DETAIL 5/A506
0706M ASSURE AN UNOBSTRUCTED DRAINAGE FLOW FROM ROOF DRAIN THROUGH INTERIOR
DRAIN LINES
0707 PROVIDE COPPER COUNTERFLASHING, SEE DETAIL 4/A-506
0708 PROVIDE A HOT RUBBERIZED ASPHALT MEMBRANE ROOF ASSEMBLY INCLUDING
INSULATION AND BALLAST
DOORS AND WINDOWS
FINISHES
0901 POWERWASH LIME WASHED SURFACES. PROVIDE PRE-WASH MINERAL PAINT FIXATIVE AND
MINERAL PAINT
0901A PREPARE SURFACE AND PAINT MINERAL COATING ON STUCCO
0902 PREPARE, PRIME, AND PAINT LATEX ON EXTERIOR BRICK
0902A PREPARE, PRIME, AND PAINT WOOD PORCH DECK UPPER AND UNDERSIDES, AND JOISTS - ALL
EXPOSED SIDES
0902B PREPARE, PRIME, AND PAINT WOOD CEILING
0902C RETAIN DECORATIVE CAST IRON RAILING/BALCONY/BRACKET IN PLACE (CIR-1). REMOVE RUST, PRIME, AND PROVIDE NEW PAINT COATING ON ALL SURFACES TO ENCAPSULATE EXISTING TO
REMAIN LBP AND TO MATCH EXISTING COLOR.
0902D REMOVE RUST, ABATE LBP, PRIME, AND PAINT ALL SURFACES OF IRON RAILING AND LADDER
TO MATCH THE EXISTING COLOR. TOOL GROUT TO HAVE POSITIVE SLOPE AWAY FROM POST
BASE
0902E PREPARE, PRIME, AND PAINT FERROUS SHEET METAL SURFACE
0902F PREPARE, PRIME, AND PAINT WOOD SHUTTERS ALL SIDES. REINSTALL.
0902G PREPARE, PRIME, AND PAINT WOOD MOULDING/ TRIM
0902H PREPARE, PRIME AND PAINT METAL VENTS TO MATCH EXISTING COLOR
0902I PRIME AND PAINT DOWNSPOUTS TO MATCH NEW WALL COLOR. (TAYLOE HOUSE WEST
FACADE, MATCH EXISTING CONTRASTING COLOR)
0902J PRIME AND REPAINT METAL AND WOOD CORNICE AND BRACKETS TO MATCH EXISTING COLOR
0902K PREPARE, PRIME, AND PAINT ALL SURFACES OF WROUGHT IRON BALCONY BEFORE
REINSTALLATION, TOUCH-UP AFTER INSTALLATION. MATCH EXISTING COLOR.
0902L PREPARE, PRIME, AND PAINT ALL SURFACES OF THE STEEL GRILL AND LIGHTWELL COVER
BEFORE REINSTALLATION, TOUCH-UP AFTER INSTALLATION. MATCH EXISTING COLOR.
0902M PREPARE, PRIME, AND PAINT ALL SURFACES OF THE STEEL GRILL COVER BEFORE
REINSTALLATION, TOUCH-UP…
This is the start of the file's text. The full file is on GovTribe.