This document is a lighting specifications and product selection guide for the Beaufort County Courthouse Renovation – Phase I project in South Carolina, compiled by lighting design professionals to support general contractor proposals. The file contains detailed technical specifications and ordering information for multiple LED lighting products, including exit signs (Exitronix 400EX Series die-cast aluminum fixtures), linear LED striplight systems (SLSTP Lensed Cooper Lighting Solutions), pendant fixtures (Visa Lighting Olympia Cable Suspension), recessed downlighting systems (HALO Commercial HCD 8" Round Direct Mount), LED backlit panel systems (CGTS Selectable Lumens and CCT), regress mount accessory kits (RMK2), and architectural recessed troffers (OnCurve Wave-XL LED 4x4). The specifications encompass various lumen outputs ranging from 500 to 14,000 lumens, color temperature options from 2700K to 5000K, dimming capabilities (primarily 0-10V), and emergency battery backup options. All fixtures are designed for indoor commercial applications such as courtrooms, offices, and educational facilities, with certifications for damp locations and compliance with codes including UL, NEC, NFPA 101, and California Energy Commission Title 20.
The specifications reflect a comprehensive approach to courthouse renovation lighting needs, incorporating energy-efficient LED technology with lumen maintenance of at least 60,000 hours at L70-L80 levels, resulting in efficacies ranging from 100 to 151.7 lumens per watt depending on fixture type and configuration. Multiple fixtures offer WaveLinx wireless control integration for occupancy sensing, daylighting, and scene management. Pricing details are not explicitly stated in the document; however, all specifications include five-year limited warranty coverage and various factory installation options for emergency lighting packs and integrated controls. The document serves as a technical reference guide enabling contractors to understand product specifications, ordering codes, dimensional requirements, and installation details necessary for bid preparation and project execution without establishing specific contractual pricing, delivery schedules, or site-specific terms.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| BEAUFORT_COUNTY_COURTHOUSE_RENOVATION_–_PHASE_I.pdf | ||
| 2026.06.09_-_CD_BID_SET_-_DRAWINGS.pdf | ||
| E0-1.dwg | DWG drawing | |
| P1-1.dwg | DWG drawing | |
| M2-1.dwg | DWG drawing | |
| A9-1.dwg | DWG drawing | |
| M2-2.dwg | DWG drawing | |
| E2-1.dwg | DWG drawing | |
| E1-1.dwg | DWG drawing | |
| A1-2.dwg | DWG drawing | |
| A3-1.dwg | DWG drawing | |
| A4-3.dwg | DWG drawing | |
| A4-2.dwg | DWG drawing | |
| A2-1.dwg | DWG drawing | |
| M1-2.dwg | DWG drawing | |
| A2-2.dwg | DWG drawing | |
| A4-4.dwg | DWG drawing | |
| A4-1.dwg | DWG drawing | |
| A0-1.dwg | DWG drawing | |
| P2-1.dwg | DWG drawing | |
| G0-1.dwg | DWG drawing | |
| 2026.06.09_-_CD_BID_SET_-_PROJECT_MANUAL.pdf | ||
| P0-1.dwg | DWG drawing | |
| E0.1_07-13-2026.pdf | ||
| M1-1.dwg | DWG drawing | |
| BC_Family_Court_2_ACM_Report.pdf | ||
| PAGE_8_-_VECTOR.pdf | ||
| BC_Family_Court_1__ACM_Report.pdf | ||
| M0-1.dwg | DWG drawing | |
| BC_1st_floor_ACM_Report.pdf | ||
| Exhibit_4_-_Monthly_Compliance_Status_Report.pdf |
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Specifications are subject to change without notice.
Installation must be performed in accordance with Barron Lighting Group installation instructions.
800.533.3948 • barronltg.comPage 1 of 2
400EX Series Die-Cast Aluminum LED Exit
FEATURES & BENEFITS
• Specification-grade exit sign with an enclosure constructed of precision die-cast aluminum
| • | Field-selectable directional chevron knockouts |
| • | Optional Guardian Self-test/Self-diagnostics (G2) available |
| • | Buy American Act (BAA) compliant |
Exitronix die-cast aluminum exit signs are designed to combine both elegance and performance while maintaining optimal energy-efficiency with bright, uniform illumination.
SPECIFICATIONS
Illumination: Constant, uniform illumination by long-life, high-intensity red or green LEDs Housing: Die-cast aluminum Input: 120/277VAC Dual Primary, 50/60Hz Battery: Maintenance-free NiCad battery Operating Temp: 0°C to 50°C (32°F to 122°F) Run Time: UL Listed 90 minute emergency run time, 24 hour recharge time Mounting: Ceiling, end or wall mount, mounting canopy included Finishes: Black, Brushed Aluminum or White Certifications: UL 924 Listed for Damp Locations, Meets or exceeds NFPA 101 Life Safety Code, NEC, OSHA, and California Energy Commission (CEC) Title 20 requirements
Warranty: Any component that fails due to a manufacturing defect is guaranteed for 10 years with a separate five year prorated warranty on the battery. The warranty does not cover physical damage, abuse or instances of uncontrollable natural forces. See the full Exitronix warranty document for detailed information. (Terms and Conditions apply)
5.5” 4.5”
9.0”8.5”
2.1”12.5”
10800354 Rev 7
ORDERING INFORMATION Example: 402EX-WB-BA-G2 Series Power Source Finish Options (Factory Installed) 402EX = Red Single-Face LB = AC Only BA = Brushed Alum. w/ Alum. Face G21 = Self-test/Self-diagnostics 403EX = Red Double-Face WB = NiCad Battery (std) BB = Black w/ Black Face 220V = 220VAC, 50Hz Input G402EX = Green Single-Face 2CI1 = 120V 2 Circuit Input BL = Black w/ Alum. Face TRH2 = Tamper Resistant Hardware G403EX = Green Double-Face 2CI7 = 277V 2 Circuit Input WW = White w/ White Face
Accessories3 (Field Installed) ER1-KIT = 1’ Pendant Mount Kit
Notes Note: See Specialty Signage specification for custom/alternate legends
ER2-KIT = 2’ Pendant Mount Kit 1 Available with battery (WB) units only WG-S = Wire Guard (Back Mount) 2 TRH is not a UL Listed option XG-1 = Poly Guard (Back Mount) 3 Order as separate line item XG-3 = Poly Guard (Ceiling Mount) https://barronltg.com/category.php?category=Exitronix-Specialty-Signage&id=52 pkeew Text Box
EX
Specifications are subject to change without notice.
Installation must be performed in accordance with Barron Lighting Group installation instructions.
800.533.3948 • barronltg.comPage 2 of 2
CONSTRUCTION
The 400EX Series exit is constructed of a specification-grade die-cast aluminum body with soft corners designed for traditional mounting as well as conduit entry and pendant mounting. Clear finish on brushed face prevents fingerprints or other surface impurities. Field-selectable chevron knockouts are concealed and easily removed. All units are supplied with mounting canopy for ceiling, end or wall mounting.
Stencil letters are 6” high with 3/4” stroke.
ILLUMINATION
Illumination of the 400EX Series is accomplished utilizing high-intensity, long-life LEDs. LEDs are a maintenance-free solution, providing up to 100,000 hours of use without failure.
ELECTRICAL
Input Dual-voltage input 120 or 277VAC @ 50/60Hz.
Nickel Cadmium Battery - NiCad (Standard) Exitronix nickel cadmium batteries are maintenance-free.
Two-Circuit Operation (2CI1 or 2CI7) Two-circuit input allows for a primary and auxiliary power source to be connected to an emergency unit that does not contain a battery.
Applications include those with inverters or alternate backup power sources.
Solid-State Transfer The circuit features solid-state switching for emergency mode, eliminating concerns of damaged contact or mechanical failures associated with relays. The switching circuit detects a loss of line voltage and automatically switches to emergency mode.
Test Button The test button is easy to locate and provides manual verification of the transfer circuit and emergency lamps.
INSTALLATION
Installs in minutes with easy-to-read instructions and detailed diagrams.
No special hardware or tools necessary. Internally housed components and battery eliminate the use of a canopy when wall mounting single-faced exits.
OPTIONS
Guardian Self-Test/Self-Diagnostics (Option: G2) The Guardian bi-color circuit is factory preset; without any field adjustments needed. It continuously monitors the performance condition of the AC power, battery supply and charging circuitry.
The intent of this option is to provide visual signaling to identify fault at the exit. Fault indicators are as follow:
Battery Disconnection: (Steady RED) Battery Recharge Failure: (Flashing RED) Battery Failure: (RED Blinking ‘2’ times) LED Failure: (RED Blinking ‘3’ times)
Specialty Signage For custom/alternate legends, see our Specialty Signage specifications.
CONFORMANCE TO CODES & STANDARDS
The 400EX Series is UL 924 Listed for Damp Locations and meets or exceeds the following: CEC (T20), NEC requirements and NFPA 101.
10800354 Rev 7 https://barronltg.com/category.php?category=Exitronix-Specialty-Signage&id=52
Project Catalog # Type
Prepared by Notes Date
PS51969122 page 1 December 10, 2025 12:32 PM
End view, Endcap no Sensor End view, Endcap with Sensor
3-3/16" [82mm]
2-11/16" [68mm]
2-9/16" [66mm]
2-9/16" [66mm]
2-7/16" [60mm]
2-1/2" [63mm]
Standard view, no Endcap
Top Product Features
| • | External selectable switches provide easy, in field customization |
| • | (3) color temperature and lumen select option provide application versatility |
| • | Single frost lens (no breaks) provides clean, continuous lighting layout |
| • | Up to 143 LPW and DLC compliant to enable rebates and energy savings |
| • | Available in 8ft, 4ft and 2ft lengths, single and continuous mount capable |
| • | UNV and 347V driver with 0-10V dimming, 10% standard |
| • | Jbox cover, decorative endcap included to complete install. |
Typical Applications Commercial • Industrial • Retail • Residential
SLSTP Lensed LED
Selectable CCT and Lumen LED Striplight additional product diagrams
Dimensional and Mounting Details
Interactive Menu
• Order Information page 2
• Photometric Data page 4
• Sensor Coverage page 5
• Product Warranty
Product Certification
Product Features
2 ft.
8 ft.4 ft.
Lumen/ Color Select
Switches
J-box Cover and Endcap included
Cover for junction box is shipped standard with fixture, along with hardware to secure cover to J-box.
https://www.cooperlighting.com/global/resources/legal https://www.cooperlighting.com/global/brands/mws.html
SLSTP Lensed
PS51969122 page 2 December 10, 2025 12:32 PM
Input Current (A)
Catalog # UPC Length CCT (K) Delivered Lumens Watts Efficacy (lm/W) Dimming 120V 277V 347V
2SLSTPSC-UNV 080083174409 2
3500 2445 22 113
0-10V Dim to 10%
0.18 0.08
-4000 2585 21 123 0.17 0.08
5000 2470 21 115 0.18 0.08
4SLSTPSLC-UNV 080083174416 4
3500 2416 18 133
0-10V Dim to 10%
0.15 0.07
-4000 2418 18 137 0.15 0.06
5000 2383 18 134 0.15 0.06
3500 3534 31 115 0.26 0.11
-4000 3627 30 122 0.25 0.11
5000 3523 30 116 0.25 0.11
3500 5802 48 121 0.40 0.17
-4000 6045 46 130 0.39 0.17
5000 5784 48 121 0.40 0.17
8SLSTPSLC-UNV 080083174423 8
3500 4215 34 125
0-10V Dim to 10%
0.28 0.12
-4000 4321 33 130 0.28 0.12
5000 4288 34 127 0.28 0.12
3500 7782 64 121 0.54 0.23
-4000 8141 63 130 0.52 0.23
5000 7901 64 123 0.54 0.23
3500 10456 88 118 0.74 0.32
-4000 11119 85 130 0.71 0.31
5000 10456 89 118 0.74 0.32
2SLSTPSC-347 080083249442 2
3500 2489 22 114
0-10V Dim to 10%
- - 0 .0 6
4000 2631 21 125 - - 0.06
5000 2538 22 117 - - 0.06
4SLSTPSLC-347 080083249466 4
3500 2339 18 127
0-10V Dim to 10%
- - 0.05
4000 2446 18 134 - - 0.05
5000 2386 18 130 - - 0.05
3500 3479 31 113 - - 0.09
4000 3669 30 121 - - 0.09
5000 3550 31 115 - - 0.09
3500 5736 47 122 - - 0.14
4000 6115 46 133 - - 0.13
5000 5852 47 124 - - 0.14
8SLSTPSLC-347 080083249480 8
3500 4419 33 136
0-10V Dim to 10%
- - 0.09
4000 4556 32 143 - - 0.09
5000 4521 32 140 - - 0.09
3500 7937 64 124 - - 0.18
4000 8325 62 134 - - 0.18
5000 8254 65 127 - - 0.19
3500 10622 87 123 - - 0.25
4000 11202 84 134 - - 0.24
5000 10692 86 124 - - 0.25
Shipping Data
Catalog Base Wt. (lbs) Unit per Pallet
Case Pack Qty.
2SLSTP 2.5 180 6
4SLSTP 4.5 120 4
8SLSTP 8 100 2
Energy Data - 120V
2' 4'' 8’
PF 0.99 0.99 0.99
THD% < 8.5 < 9.9 < 8.1
Low Temp Start -20°C -2 0°C -20°C
Order Information and Performance Data Default CCT/Lumen Setting: 4000K / Med Power
PS51969122 page 3 December 10, 2025 12:32 PM
Product Specifications
Catalog Emergency Battery Installed (2), (4)
4SLSTP* - BSL6 = Bodine 6W Emergency BSL10 = Bodine 10W Emergency8SLSTP* -
Example: 4SLSTPSLC-UNV-BSL10
Catalog Unit UPC Unit Carton Qty Case Qty
SLSTP MS00 Kit 080083254200 1 50
SLSTP MS25 Kit 080083254224 1 100
Catalog Unit UPC Unit Carton Qty Case Qty
SLSTPROW88 080083815654 1 50
SLSTPROW842 080083815661 1 100
R O W A L I G N E R 8 ' - 8 ' R O W A L I G N E R 8 ' - 4 '
Accessories Mounting AYC-Chain/Set=36" Hanging Chain Set w/V Hooks Y-TOGGLE-10-2PK=(2) Y-Toggle Cable Kits at 10FT long (3) SCF-12-B=12" Fixed Stem Set (specify if another length is needed) (1)
Emergency and Sensor EBPLED7W=User Installed, Remote Mount, 7 Watt LED Emergency Battery Pack EBPLED14W=User Installed, Remote Mount, 14 Watt LED Emergency Battery Pack SLSTP MS00 Kit=Field installable sensor kit, PIR Sensor 100% 50% OFF (5)
SLSTP MS25 Kit=Field installable sensor kit, PIR Sensor 100% 50% Low (~30%) (5)
Wireguard, Row-mount and Lens WG-SLSTP-4=Wireguard 46.3", nominal 4FT WG-SLSTP-2=Wireguard 23", nominal 2FT SLSTPROW88=8ft to 8ft continuous row bracket SLSTPROW842=8ft to 4ft or 2ft continuous row bracket 2SLSTPLNS=2 ft. Replacement Lens 8SLSTPLNS=8 ft. Replacement Lens
Notes: (1) For stem, order two per fixture.
(2) For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 7=700 lumens).
(3) Continuous row mount only between fixtures.
(4) EBP not available at 347V.
(5) Sensor info and coverage on page 5.
Construction
• Fixture channel, cover and end plates are formed from cold rolled steel
• Decorative end caps snap-on for an improved aesthetic finish
• Suitable for either single or continuous row applications
Electrical
• Long-Life LED system with an energy-efficient electronic driver comes in UNV (120-277V) or 120/347V versions
| • | Available with 0-10V dimming |
| • | CCT Selectable option for maximum color flexibility: |
choose from 3500K, 4000K or 5000K
• LED and Light Engine
• Lumen select switch provides three lumen package choices (Low, Medium and High)
• L70 at >50,000 hours (TM-21), over 23 years at 6 hrs/day
| • | CRI 83 or better |
| • | Default CCT/Lumen setting is 4000K and Med |
Power
Controls
• Maximize energy savings - combine with products like occupancy sensors, daylighting controls, and lighting relay panels
• Standard 0-10V continuous dimming driver works with any standard 0-10V control/dimmer
• Dimming range is 10% to 100% and varies by control device
• Purple and grey (pink) low voltage dimming leads required from 0-10V dimmer switch to fixture
• PIR occupancy sensors enables code compliance.
Refer to accessory kit and page 5 for setting levels.
• Sensor kit can be field installed. Add up to (20) 4ft or (10) 8ft fixtures per single sensor kit. Kit is end mount only.
Finish
• Post painted with high reflective paint – standard, for ease of handling
Shielding
• Frost, polycarbonate lens with linear prisms for uniform light distribution
Emergency Battery Pack Option
• Factory installed 120V-277V integral emergency battery pack available via mod-shop.
| • | 90-minute backup period for code compliance |
| • | Factory installed integral test switch visible from |
room side
Installation
| • | May be surface, suspended, or wall mounted |
| • | Multiple 7/8” K.O. on back and one on each end |
| • | Jbox cover, wire nuts and decorative end caps |
included
Compliance
| • | cULus listed for damp location rated |
| • | LED’s comply with IESNA LM-79 and LM-80 |
standards
• DesignLights Consortium® Qualified and classified for DLC Standard, refer to www.designlights.org for details
| • | RoHS compliant |
| • | Suitable for use in closet storage spaces when |
installed in accordance with NFPA-70 and NEC
410.16 spacing requirements
Warranty
• Five year limited warranty
S L S T P M O T I O N S E N S O R K I T - See page 5 for sensor info and coverage area
Factory Installed Mod Shop Option http://www.cooperindustries.com/content/dam/public/lighting/about%20us/terms_and_conditions/Lighting-Division-TC-Matrix.pdf
PS51969122 page 4 December 10, 2025 12:32 PM
View IES filesPhotometric Data
0-deg 90-deg
180° 170°160° 150°
140° 130°
120°
110°
100°
90°
80°
70°
60°
50° 40°
30° 20°10°0°
0.0
4SLSTPSLC-UNV
Electronic Driver Linear LED 4000K Spacing criterion: (II) 1.28 x mounting height, (⊥) 1.32 x mounting height Lumens: 2418 Input Watts: 17.6W Efficacy: 137 LPW Test Report: 4SLSTPSLC-UNV-LO-
4000K.IES
0-deg 90-deg
180° 170°160° 150°
140° 130°
120°
110°
100°
90°
80°
70°
60° 50°
40° 30°
20°10°0°
0.0
8SLSTPSLC-UNV
Electronic Driver Linear LED 4000K Spacing criterion: (II) 1.28 x mounting height, (⊥) 1.32 x mounting height Lumens: 4321 Input Watts: 33.2W Efficacy: 130 LPW Test Report: 8SLSTPSLC-UNV-LO-
4000K.IES
0-deg 90-deg
180° 170°160° 150°
140° 130°
120°
110°
100°
90°
80°
70°
60°
50° 40°
30° 20°10°0°
0.0
4SLSTPSLC-UNV
Electronic Driver Linear LED 4000K Spacing criterion: (II) 1.28 x mounting height, (⊥) 1.32 x mounting height Lumens: 3627 Input Watts: 29.7W Efficacy: 122 LPW Test Report: 4SLSTPSLC-UNV-MID-
4000K.IES
0-deg 90-deg
180° 170°160° 150°
140° 130°
120°
110°
100°
90°
80°
70°
60°
50° 40°
30° 20°10°0°
0.0
8SLSTPSLC-UNV
Electronic Driver Linear LED 4000K Spacing criterion: (II) 1.28 x mounting height, (⊥) 1.32 x mounting height Lumens: 11119 Input Watts: 85.4W Efficacy: 130 LPW Test Report: 8SLSTPSLC-UNV-HI-
4000K.IES
0-deg 90-deg
180° 170°160° 150°
140° 130°
120°
110°
100°
90°
80°
70°
60°
50° 40°
30° 20°10°0°
0.0
4SLSTPSLC-UNV
Electronic Driver Linear LED 4000K Spacing criterion: (II) 1.28 x mounting height, (⊥) 1.32 x mounting height Lumens: 6045 Input Watts: 46.4W Efficacy: 130 LPW Test Report: 4SLSTPSLC-UNV-HI-
4000K.IES
0-deg 90-deg
180° 170°160° 150°
140° 130°
120°
110°
100°
90°
80°
70°
60°
50° 40°
30° 20°10°0°
0.0
8SLSTPSLC-UNV
Electronic Driver Linear LED 4000K Spacing criterion: (II) 1.28 x mounting height, (⊥) 1.32 x mounting height Lumens: 8141 Input Watts: 62.5W Efficacy: 130 LPW Test Report: 8SLSTPSLC-UNV-MID-
4000K.IES
https://www.cooperlighting.com/global/brands/metalux/867561/slstp-series
Cooper Lighting Solutions 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com
© 2025 Cooper Lighting Solutions All Rights Reserved.
Specifications and dimensions subject to change without notice.
PS51969122 page 5 December 10, 2025 12:32 PM
Overall Dimensions
Mounting Dimensions
WITH DECORATIVE ENDCAP
23-3/8" [594mm] 23-5/16" [588mm] NO ENDCAPS
11-11/16" [297mm] 2-1/8"
[54mm]
2' 42-1/4" [1074mm] 37-1/8" [944mm]
WITH DECORATIVE ENDCAP
4'
46-1/2" [1181mm] 46-3/16" [1175mm] NO ENDCAPS
2-1/8" [54mm]23-1/4" [591mm]
88" [2237mm] 80-1/8" [2037mm] 47-1/4" [1201mm]
96" [2440mm] 95-3/4" [2433mm] NO ENDCAPS
48" [1220mm]
7-7/8" [201mm]
4" [101mm]
8'
WITH DECORATIVE ENDCAP
4ft = 48" [1222mm] 8 ft = 97-3/4" [2481mm]
2-7/16" [63mm]
2ft = 23-3/16" [588mm] 4ft = 46-1/4" [1175mm]
8 ft = 95-15/16" [2434mm]
2ft = 23-1/2" [594mm] 4ft = 46-1/2" [1181mm]
8 ft = 96-1/16" [2440mm]
NO ENDCAP
WITH ENDCAP
2-9/16" [66mm]
2-9/16" [66mm]
2-7/16" [60mm]
2-1/2" [63mm]
2-7/16" [61mm]
3-3/16" [81mm]
2-3/4" [68mm]
Sensor Coverage (MS Sensor Kit) S I D E V I E W
Motion Detected
100%
50%
~30%
0% m in s ec on ds
7.
m in m in ∞
Time (in minutes)
Li gh t O ut pu t (
) SLSTP MS00 KIT
SLSTP MS25 KIT
Stand-by Time No Motion
L I G H T O U T P U T O V E R T I M E
S E N S O R C O V E R A G E P A T T E R N – T O P V I E W
Page 1800-788-VISA
Rev: 2022/03/23
VisaLighting.com
Power Art Cable™
(U.S. Patent 8,097,804 B1)
Door Height = 7' Ceiling Height = 11' Silhouette Height = 6'
OLYMPIA™
CP4191, CP4195, and CP4199 Power Art Cable™ Suspension
Type: Location:Project:
5 Year WarrantyETL Listed
Visalighting.com/products/Olympia
90˚
60˚
30˚
120˚
150˚
180˚
0˚
XPS
FEATURES
RELATIVE SCALE DRAWING
OAH is the distance (in inches) from the bottom of the fixture to the ceiling plane.
Example - OAH(36) indicates an overall fixture height of 36”
� OAH must be specified
W = Width OAH = Standard Overall Height X = Body Height
NBS= Nominal Bowl Size
DIMENSIONS 1, 5
CP4191 CP4195 CP4199
W 26” (660 mm) 33-7/8” (860 mm) 40-5/8” (1032 mm)
OAH 25” (635 mm) 32” (813 mm) 38” (965 mm)
X 7” (178 mm) 9” (229 mm) 10-1/2” (267 mm)
NBS 23x5” (584x127 mm) 31x7” (787x178 mm) 37x9” (940x229 mm)
• Integral driver
• Modular design for replacement of LED source and driver
• Easy toolless bowl cleaning
• Patented Power Art Cable™ mounting system uses a braided stainless steel jacket to encapsulate power conductors and provide support. Rated for loads up to 150 lbs (ETL listed to UL standards)
• Mounts to standard electrical junction box (by others) with provided hardware for ceiling slopes up to 45 degrees from horizontal (CP4191 and CP4195)
• Mounts through 4” octogonal by 2-1/8” deep electrical junction box(by others) to structural blocking (by others) with provided hardware for ceiling slopes up to 45 degrees from horizontal (CP4199 only)
• Spun metal trim
• Thermally formed 1/8” thick white acrylic diffuser with matte finish
• F1 rated, UV stable
• UL-94 HB Flame Class rated
• No VOC powder coat paint finish; Low VOC clear coat on metal finishes
• ETL listed for damp locations. Not suited for exterior applications
PHOTOMETRICS
W
OAH
X
Structural Blocking Required (CP4199) (See Detail on Page 2) https://visalighting.com https://www.Visalighting.com/products/Olympia
VisaLighting.com800-788-VISA Page 2
OLYMPIA (cont.)
CP4191, CP4195, and CP4199 Power Art Cable Suspension
AF OPTION
CP4191 CP4195 CP4199
SOURCE CCT
Uplight Downlight Uplight Downlight Uplight Downlight
Delivered Lumens
Power (Watts)
Delivered Lumens
Power (Watts)
Delivered Lumens
Power (Watts)
Delivered Lumens
Power (Watts)
Delivered Lumens
Power (Watts)
Delivered Lumens
Power (Watts)
• L30K 3000K 8300
12600
21900
67 L35K 3500K 8700 2500 13100 4300 22800 6500
• L40K 4000K 8900 2600 13500 4400 23500 6700
SOURCE 2 (Select one)
Dimmable 0-10V to 10%, Minimum 80CRI, within 3-step MacAdam
MODEL 1
CP4191
CP4195
CP4199
MVOLT
FINISH
VOLTAGE
MVOLT
DIFFUSER OPTION 3
• ABA
OPTION(S) 4
AF
DCC
XPS
SOURCE 2
• L30K L35K
• L40K
See last page for finish order codes
VOLTAGE
MVOLT 120-277V, 50/60 Hz
See page 1
OPTIONS 4 (Multiple selections allowed)
� Option availability may be interdependent with Other Options
AF Add Finial. Addition of AF option increases H dimension (height) by 1-1/8”
DCC
Damp clear coat for metal finishes (required for 5 year warranty when used in damp locations)
XPS Express 10 day shipping. Items marked with a bullet (�) are not available with XPS
DIFFUSER OPTION 3
Diffuser is matte white acrylic unless ABA option is selected
• ABA Hand Painted Alabaster Alternative
ABA
OAH 5
See page 1
Special support yoke provided for fixture applications over 50 lbs.
See VisaLighting.com for more installation details
4" x 2-1/8" junction box
STRUCTURAL BLOCKING DETAIL (CP4199)
Fill in shaded boxes using information listed below https://visalighting.com https://www.Visalighting.com
Page 3VisaLighting.com800-788-VISA
OLYMPIA (cont.)
CP4191, CP4195, and CP4199 Power Art Cable Suspension
See Visalighting.com/products/Olympia for more information
• Custom colors
• Integrate accents and trim from other product designs
• Larger diffuser sizes available
SUGGESTED VARIATIONSOLYMPIA PRODUCT FAMILY
Sconces 18” Deep Bowl • CB3462
20” Shallow Bowl • CB3464
Surface Mount Ceiling Units
18” Deep Bowl • CM1101
26” Shallow Bowl • CM1103
Stem Suspension Pendants
26” Bowl • CP4151
34” Bowl • CP4155
41” Bowl • CP4159
Cable Suspension Pendants
26” Bowl • CP4191
34” Bowl • CP4195
41” Bowl • CP4199 https://visalighting.com https://www.Visalighting.com/products/Olympia https://www.Visalighting.com/products/Olympia/CB3462 https://www.Visalighting.com/products/Olympia/CB3464 https://www.Visalighting.com/products/Olympia/CM1101 https://www.Visalighting.com/products/Olympia/CM1103 https://www.Visalighting.com/products/Olympia/CP4151 https://www.Visalighting.com/products/Olympia/CP4155 https://www.Visalighting.com/products/Olympia/CP4159 https://www.Visalighting.com/products/Olympia/CP4191 https://www.Visalighting.com/products/Olympia/CP4195 https://www.Visalighting.com/products/Olympia/CP4199
VisaLighting.com800-788-VISA Page 4
This document contains information which is the property of Visa Lighting, and may not, in whole or in part, be duplicated, disclosed, or used for design or manufacturing purposes without the prior written permission of Visa Lighting. ©Visa Lighting. Design Modification Rights Reserved. Visa Lighting reserves the right to change specifications for product improvement without notification.
FINISHES
Specify color code when ordering. For accurate color matching, individual paint and finish samples are available upon request.
For more information about our finishes visit visalighting.com/finishes
Powder Coat Paint Finishes (Standard)
AGGY Agate Grey ALGN Alpine Green BJBG Baja Beige BMAT Bronze Matte BRNZ Bronze BSIL Blade Silver CVBL Cove Blue
DEOR Deoro Gold GLWT Glacier White GSIL Graphite Siver HRGR Harbor Grey JTBK Jet Black OCBL Ocean Blue SHGR Shoreline Grey
SBGN Sagebrush Green
SLGR Slate Grey SSTP Sierra Taupe TRCN Terracotta Canyon
TRWT Traffic White VBLK Velvet Black VNRD Vineyard Red
Alternative Metal Finishes (Premium) Metal Finish (Premium)
BBA Brushed Brass Alternative
BCA Brushed Chrome Alternative
BUA Brushed Copper Alternative
BZA Brushed Bronze Alternative
BA Brushed Aluminum
PB Polished Brass
OBA Oil-Rubbed Bronze Alternative
PRA Pewter Alternative
RBA Rustic Brass Alternative
SNA Satin Nickel Alternative
BB Brushed Brass
C
OLYMPIA (cont.)
CP4191, CP4195, and CP4199 Power Art Cable Suspension
PB (Polished Brass) and BB (Brushed Brass) not available on CP4195 and CP4199
PB (Polished Brass) and BB (Brushed Brass) available with CP4191 only https://visalighting.com https://visalighting.com/material-finishes-request https://visalighting.com/finishes
PS51761324-8R page 1 February 11, 2026 11:20 AM
HCD Professional Direct Mount Commercial Downlighting System 8" • Round • Downlight/Wall Wash The HCD System offers total flexibility as a modular downlighting system built on a series of Factory Preset or Selectable (Lumen/ CCT) LED Module Kits that easily interchange with a complete fleet of reflectors. Available in both rounds and squares, in multiple sizes and beam distributions. HCD installs-from-below and mounts securely to any retrofit/remodel/new construction ceiling.
*T24 and RoHS are self-tested by Cooper Lighting Solutions. Not a third party certification.
Typical Applications Healthcare • Hospitality • Education • Mixed Use • Services • Retail
LITE
WaveLinx
PRO
WaveLinx
Interactive Menu
• Order Information page 2
• Product Specifications page 4
• Product Dimensions page 6
• Energy Data page 11
• Photometric Data page 13
• Dimming Guide
Top Product Features
| • | 8" install-from-below retrofit/remodel or add mounting frames for new construction |
| • | All HCD Module Kits fit all HCD trims - all sizes and shapes |
| • | Factory preset or Field-Selectable Lumens: Options from 500 to 5000 lms (nominal) |
| • | Factory preset or 5-color Field-Selectable CCT: 2700K, 3000K, 3500K, 4000K, 5000K |
| • | 90 CRI Standard |
| • | Distributions: Precision-formed round reflectors - Medium / Wide / Narrow (match HC Series) |
| • | Field-installed wall wash distribution lens kit available |
| • | Finishes: Specular, Haze (Semi-Specular), Matte White (paintable), and Matte Black reflectors |
| • | Dimming: 0-10V down to 1% (dim-to-off with WaveLinx) in UNV 120–277V; 347V (Canada) |
| • | Emergency battery backup, WaveLinx Wireless PRO/LITE, and Chicago Plenum options available |
| • | L80 at 60,000 hours (80% lumen maintenance at 60,000 hours) |
| • | 5-year warranty |
| • | Options to meet Build America, Buy America, Buy American and other domestic preference requirements |
View Sales Guide
AVAIL ABL E
CO
MPLIANT OPTIONS
BABA
BUILD AMERICA
BUY AMERICA
Frameless, Install from below Mounting Frame Installation https://www.cooperlighting.com/api/assets/v1/file/CLS/content/halocommercial-hcd-dimming-guide/HALO-Commercial-HCD-Dimming-Guide.pdf https://www.cooperlighting.com/api/assets/v1/file/CLS/content/halocommercial-hcd-pro-system-spec-guide-brochure/HALO-Commercial-HCD-Pro-Direct-Mount-System-Sales-Guide.pdf
HCD 8" Round Direct Mount Downlights & Wall Washers
PS51761324-8R page 2 February 11, 2026 11:20 AM
Example Order Numbers:
1) Mounting Frame 2) Module Kit 3) Reflector
2 Part Luminaire:
Direct-Mount (New Construction, Retrofit, or Remodel)
[No Frame] HCDQCLS510CSD HCD8TRCWF
3 Part Luminaire:
New Construction with Frame
HCD8MFRQC HCDQCLS510CSD HCD8TRCWF
Fixture Order Information (a complete luminaire consists of 2 or 3 parts)
Mounting Frames Order Information
Domestic Preferences (2) New Construction Mounting Frames
[Blank]=Standard BAA=Buy American Act BABA=Build America Buy America Act TAA=Trade Agreements Act
Basic New Construction Mounting Frames HCD8MFR = 8" Round mounting frame Ceiling cut-outs: Round 8.25"
Description: Basic mounting frame only, no additional junction box for through-wiring. (Thumb screws on frame for securing the Module Kit Driver-Box.) Install frame and LED Module kit together during rough-in phase. Installer supplies wire to Module Kit.
Junction Box New Construction Mounting Frames HCD8MFRJB = 8" Round mounting frame Ceiling cut-outs: Round 8.25"
Description: Mounting frame with Trade-Size Junction Box for through-wiring. Thumb screws on frame for securing the Module Kit Driver-Box. Install frame and LED Module kit together during rough-in phase. Installer provides wire to junction box and between junction box and Module Kit.
Quick Connect New Construction Mounting Frames HCD8MFRQC = 8" Round mounting frame Ceiling cut-outs: Round 8.25"
Description: Mounting frame with Trade-Size Junction Box for through-wiring and Quick Connect flex. Quick Connect has 5-conductor plug-ins for power and 0-10V dimming. (Thumb screws on frame for securing the Module Kit Driver-Box.) Only frame is required at rough-in. Module Kit and Reflector installed during trim-out phase with Quick Connect. Installer provides wire to mounting frame junction box only.
Chicago Plenum New Construction Mounting Frames HCD8MFRCP = 8" Round mounting frame Ceiling cut-outs: Round 8.25"
Description: Chicago Plenum mounting frame with CCEA compliant Trade-Size Juntion box for through-wiring.
(Thumb screws on frame for securing the Module Kit Driver-Box.) Install frame and LED Module kit together during rough-in phase. Installer provides wire to junction box and between junction box and Module Kit.
Notes
(2) Only product configurations with these prefixes are built to be compliant with the Buy American Act of 1933 (BAA), Trade Agreements Act of 1979 (TAA), or the Build America Buy America Act (BABA). BABA is the minimum Government compliance requirement for the Build America Buy America standards which is part of the Infrastructure and Investment Jobs Act (IIJA). Individual Government Agencies may have more stringent compliance standards. Please refer to DOMESTIC PREFERENCES website or consult the CLS Domestic Preferences team for more information. Components shipped separately may be separately analyzed under domestic preference requirements.
Mounting Frame Notes
• Type-IC with low-lumen module kits 500-750-1000lm
• Type Non-IC with mid-lumen 1500-2000-2500lm
• Type Non-IC, Marked Spacing with mid/high-lumen 3000-3500-4000lm and high-lumen 4000-4500-5000lm module kits (36" center-to-center, 18" center to building member, 0.5" minimum overhead spacing).
• Chicago Plenum (CP) new construction mounting frames are CCEA compliant with pre-installed J-box for mains input, and Type Non-IC rated per CCEA
HCD Module Kit & Mounting Frame Compatibility
HCD Pro System downlights can be installed as retrofit, remodel, direct-mount new construction, or traditional frame new construction.
All HCD Module Kits fit all HCD trims.
Frameless Mounting Frames
Retrofit, remodel, and new construction direct-mount
Basic Junction Box Quick Connect Chicago Plenum
M od ul e
Ki ts
Junction Box (Base) 1 1 2
Quick Connect (includes EM & WLX options) 3 4 5
Chicago Plenum
1. Installer provide mains wiring & connection to Module Kit driver box.
2. Installer provide mains wiring & connection to Frame junction box and/or Module Kit driver box.
3. Frame and mains-half of provided quick connect installed before finished ceiling; module kit and trim installed after finished ceiling.
4. Mains-half of quick connect can be field-installed in frame junction box, or connected directly to mains.
5. Note: Mains-half of quick connect included with module kit will be recycled in this configuration.
https://www.cooperlighting.com/global/resources/programs/iija
PS51761324-8R page 3 February 11, 2026 11:20 AM
Domestic Preferences (2) Module Kit
[Blank]=Standard BAA=Buy American Act BABA=Build America Buy America Act TAA=Trade Agreements Act
Junction Box Module Kit HCDJB = 8" Junction Box Module Kit: LED Engine & Driver on 20" flex conduit (Input wiring and connectors by installer).
Qu ic k Co nn ec t
Quick Connect Module Kit HCDQC = 8" Quick Connect Module Kit: LED Engine & Driver on 20" flex conduit w/ 5-conductor quick connect on flex conduit & 1/2" snap-fitting for input knock out.
Quick Connect Emergency Module Kit HCDE = 8" Emergency Module Kit: LED Engine & Driver with Battery Pack on 20" flex conduit w/ 6-conductor quick connect on flex conduit & 1/2" snap-fitting for input knock out. Emergency battery with test switch is attached to module kit driver box.
Add emergency option code to model number: EM06 or EM14 Note: IEM reflector must be ordered separately for integral emergency.
Quick Connect WaveLinx Wireless Module Kit HCDW = 8" WaveLinx Wireless Module Kit w/ Quick Connect: LED Engine & Driver on 20" flex conduit w/ 5-conductor quick connect on flex conduit & 1/2" snap-fitting for input knock out.
Add WaveLinx Wireless option code to model number: WPN (WaveLinx PRO) or WLN (WaveLinx LITE)
Chicago Plenum Module Kit (5)
HCDCP = 8" Chicago Plenum Module Kit: LED Engine & Driver on 18" CCEA compliant FMT and junction box with wiring for power and 0-10V dimming between LED Engine and driver box (Input FMT wiring and connectors to driver box, by others).
Notes
(2) Only product configurations with these prefixes are built to be compliant with the Buy American Act of 1933 (BAA), Trade Agreements Act of 1979 (TAA), or the Build America Buy America Act (BABA). BABA is the minimum Government compliance requirement for the Build America Buy America standards which is part of the Infrastructure and Investment Jobs Act (IIJA). Individual Government Agencies may have more stringent compliance standards. Please refer to DOMESTIC PREFERENCES website or consult the CLS Domestic Preferences team for more information. Components shipped separately may be separately analyzed under domestic preference requirements.
(5) Chicago Plenum (CP) module kits FMT conduit have larger bend radius, requiring deeper plenum height. Minimum plenum height 7.25" (2x8) with 24" grid/framing width for all Chicago Plenum module kits.
Module Kits Notes
• Module Kits are universal for all reflectors.
• For installation from below a finished ceiling, direct-mount through the ceiling opening. The installer must cutout a precise aperture opening for the appropriate reflector size.
LED Module Order Information (All Module Kits fit any HCD Reflector – 4", 6", or 8"; Round or Square)
Selectable Options (0) Driver
Lumen Selectable* LS510 = 500/750/1000lm (Preset 1000lm) Type IC, air permeable insulation contact LS1525 = 1500/2000/2500lm (Preset 2500lm) Type Non-IC, insulation 3" spacing LS3040 = 3000/3500/4000lm (Preset 4000lm) Type Non-IC, Marked Spacing, see note below*** LS4050 = 4000/4500/5000lm (Preset 5000lm) Type Non-IC, Marked Spacing, see note below***
Color Selectable* CS = 90CRI, selectable 2700K-3000K-3500K-4000K-5000K (Preset at 3500K)
Factory Fixed CCT**
927 = 90CRI, 2700K
930 = 90CRI, 3000K
935 = 90CRI, 3500K
940 = 90CRI, 4000K
950 = 90CRI, 5000K
D = Dimmable, UNV 120-277V, 50/60Hz 0-10V 1%-100% dimming at 120-277V on 0-10V controls.
Compatible with WaveLinx Wireless dim-to-off functionality.
Canada Option D347 = Dimmable 347VAC 50/60Hz 0-10V 1%-100% dimming. Available on HCDQC module kits only.
Canada only. (1)
Factory Fixed Lumens** L05 = 500 lumen – IC L07 = 750 lumen – IC L10 = 1000 lumen - IC L15 = 1500 lumen - Non-IC L20 = 2000 lumen - Non-IC L25 = 2500 lumen - Non-IC
L30 = 3000 lumen - Non-IC*** L35 = 3500 lumen - Non-IC*** L40 = 4000 lumen- Non-IC*** L41 = 4000 lumen- Non-IC*** L45 = 4500 lumen- Non-IC*** L50 = 5000 lumen- Non-IC***
Notes
(0) Selectable Lumen and Selectable CCT must be specified together – Selectable example: LS510, CS
(1) Not available with Chicago Plenum models Factory Fixed Lumen and CCT must be specified together - example: L05, 935 *Field-selected switch settings by installer accessed in hinged snap-latch cover over selectable switches, protects lumen and CCT settings yet allows for quick changes. OR **Factory preset individual switch settings secured under fixed cover. Torx screw on cover secures presets yet allows for re-set access if needed. Factory label notes preset lumen and CCT.
***3000/3500/4000, 4000/4500/5000lm Non-IC, Marked Spacing − Marked Spacing Center to Center of Adjacent Luminaires = 36" / − Center of Luminaire to Building Member = 18" / − Minimum overhead = 0.5"
Factory Options
Emergency Options (Add emergency suffix code option to HCDE emergency module kits only) EM06 = 6-watt self-test emergency battery with test switch for remote or integral test. Remote switchplate included, back box by others. Integral reflector order separately. Use with "D" driver only. Option only with HCDE module kits. (1) (3) (4)
EM14 = 14-watt self-test emergency battery with test switch for remote or integral test. Remote switchplate included, back box by others. Integral reflector order separately. Use with "D" driver only. Option only with HCDE module kits. (1) (3) (4) (7)
WaveLinx Options (Add WaveLinx suffix code option to HCDW WaveLinx module kits only) WPN = WaveLinx PRO Wireless Node & Power Pack. Add WPN code to HCDW module kits. Option only with HCDW module kits. (3) (4)
WLN = WaveLinx LITE Wireless Node & Power Pack. Add WLN code to HCDW module kits. Option only with HCDW module kits. (3) (4)
Emergency Options with WaveLinx (Add emergency with WaveLinx suffix code option to HCDE emergency module kits only) (6)
EM06WPN = 6-watt emergency with WaveLinx PRO Wireless Node EM06WLN = 6-watt emergency with WaveLinx LITE Wireless Node EM14WPN = 14-watt emergency with WaveLinx PRO Wireless Node EM14WLN = 14-watt emergency with WaveLinx LITE Wireless Node
Notes
(1) Not available with Chicago Plenum models
(3) Not available with D347 (347V models)
(4) Use with "D" driver
(6) For Emergency Options with WaveLinx, order HCDE module kit
(7) EM14 is NOT compatible with the lowest-lumen module (500/750/1000 lumen). Both battery options are compatible with all other modules.
Module Kit & LED Engine
• For use in retrofit, remodel, and new construction mounting types.
• HCD Module Kits fit all 4", 6", and 8" round or square reflectors (order module kits and reflectors separately)
• Module kit LED engines attach to reflectors with three toolless lever clamps.
• Mousetrap springs on reflectors for direct-mount from below a finished ceiling, in retrofit, remodeling or in new construction mounting frames.
• LED engine aluminum heat sinks feature passive conduction of heat away from the LED array for optimal performance and long life
• Module kits include LED engine, driver junction box, and durable metal flex conduit; with quick-connect box on applicable models
Module Kits
• HCDJB Basic Junction Box Module Kit with LED
Engine & driver box on 20" metal flex. Input wiring and connections to the driver box by installer.
• HCDQC Quick Connect Module Kit with LED Engine & driver box on 20" metal flex with 5-conductor quick-connect on a metal flex whip and 1/2" KO snap-fitting for mains terminations by others.
• HCDE Emergency Module Kit with LED Engine & driver box and battery pack & test switch on 20" metal flex with 6-conductor quick-connect on a metal flex whip and 1/2" KO snap-fitting for mains terminations by others.
• Emergency battery pack and remote test switch are attached to module kit.
• Add emergency suffix code option to catalog number: EM06 or EM14 (see Emergency Backup Options for details)
• For emergency with WaveLinx Wireless add suffix code option to catalog number of HCDE module kits only: EM06WPN, EM06WLN, EM14WPN, EM14WLN
• HCDCP Chicago Plenum Module Kit with LED Engine & driver box on 18" CCEA compliant metal flex. CCEA compliant mains and dimmer wiring to HCDCP module kit driver box by installer.
• HCDW WaveLinx Module Kit with LED Engine & driver box on a 20" metal flex with 3-conductor quick-connect on a metal flex whip and 1/2" KO snap-fitting for mains terminations by others.
• Add WaveLinx Wireless Node suffix code to catalog number: WPN - WaveLinx or WLN - WaveLinx Lite (see WaveLinx Connected Lighting website for details)
Module Kit Driver Box
| • | Galvanized steel electrical box |
| • | Integral driver |
| • | 18 cubic inch internal volume |
| • | Listed for six #12 AWG 90° C splice conductors, |
two in, two out plus ground
| • | (4) 1/2" trade size pry outs |
| • | (3) 4-port push wire nuts for mains voltage with |
1-port for fixture connection
New Construction Mounting Frames
• Galvanized steel plaster frame with integral bar hangers
| • | Available in 4", 6", 8" Round and Square |
| • | Integral 3/8" drywall/plaster collar for ease in |
position locating and ceiling cut-out
• Round aperture diameter sized for industry standard hole saws HCD8 = 8.25"
• Bar hanger vertical brackets adjust 2" vertically from above & below ceiling
• Bar hangers horizontal adjusting from 10-1/2" to
24-1/2" wide
• Setscrews provide positive horizontal and vertical locking
• Captive nail for use in standard dimensional and engineered framing lumber
• Through-hole in bar bracket ends for additional nail or screw attachment (nail or screw by others)
• Flange lip on bar bracket ends level platform in framing construction
| • | Integral grid clip attaches directly to T-grid |
| • | All mounting frames have knurled thumb screws for |
securing module kit driver box, when needed
Mounting Frame Junction Box
| • | Trade-size galvanized steel junction box |
| • | 25 in3 internal total volume |
| • | Voltage barrier for 0-10V dimming wires (occupies |
one 1/2" pry-out space)
• Listed for eight #12 AWG (four in, four out) 90˚C conductors and feed-thru branch wiring
• Three 1/2" and two 3/4" trade size pry-outs
Quick Connect Box (available on HCDQC, HCDW, HCDE Module Kits)
• Galvanized steel enclosure on metal flex conduit whip end terminating with 1/2" KO snap-fitting for mains connections by others
| • | Tool-less access snap cover |
| • | HCDQC (Quick Connect module kits) and HCDW |
(WaveLinx module kits): Quick connect 5-conductor mains & dimming in/out wiring on 3-conductor line voltage mains & 2-conductor 0-10V connectors
• HCDW Wavelinx use only the 3-condutor line quick connections
• HCDE (Emergency module kits): Quick connect 6-conductor mains & dimming in/out wiring on 4-conductor line voltage + battery mains & 2-conductor 0-10V connectors
Product Specifications continued on next page
Domestic Preferences (2) Reflectors Type Finish Emergency Wall Wash Accessory Kits (Field Installed - Order Separately)
[Blank]=Standard BAA=Buy American Act BABA=Build America Buy America Act TAA=Trade Agreements Act
Medium Reflector HCD8T = 8" Medium 70° Distribution Reflector
Wide (Shallow) Reflector HCD81T = 8" Wide (Shallow) 85° Distribution Reflector*
Narrow Reflector HCD82T = 8" Narrow 55° Distribution Reflector*
R = Round C = Specular Clear CWF = Specular Clear / White Flange CBF = Specular Clear/Black Flange H = Haze (Semi-specular) HWF = Haze (Semi-specular) / White Flange HBF = Haze (Semi-Specular)/Black Flange MW = Matte White (paintable) MWBF = Matte White/Black Flange MB = Matte Black
IEM = Reflector for use with integral emergency module kits only.
Provides access hole for emergency test switch, if integral switch is desired.
Use with HCDE emergency module kits.
Medium Wall Wash Kit HCD8TRLWW = 8" Round Lensed Wall Wash Kit
Wide (Shallow) Wall Wash Kit HCD81TRLWW = 8" Wide (Shallow) Round Lensed Wall Wash Kit
Narrow Wall Wash Kit HCD82TRLWW = 8" Narrow Lensed Wall Wash Kit
Notes
(2) Only product configurations with these prefixes are built to be compliant with the Buy American Act of 1933 (BAA), Trade Agreements Act of 1979 (TAA), or the Build America Buy America Act (BABA). BABA is the minimum Government compliance requirement for the Build America Buy America standards which is part of the Infrastructure and Investment Jobs Act (IIJA). Individual Government Agencies may have more stringent compliance standards. Please refer to DOMESTIC PREFERENCES website or consult the CLS Domestic Preferences team for more information. Components shipped separately may be separately analyzed under domestic preference requirements.
Reflector Notes:
• Reflectors work with all module kits
• Compatible with HCD8MFR* round aperture mounting frames
• Reflectors attach to module kits and install from below the ceiling opening with integral mousetrap springs
• Maximum ceiling thickness 1.5"
• Wall wash kits are accessories for field installation
• Direct-mount requires a precise aperture cutout
• 8" Round = 8.25" Retrofit & New Emergency IEM Notes:
• Emergency battery with test switch is attached to module kit.
• Add emergency suffix code to HCDE model number: EM06 or EM14
* IEM reflector ordered separately.
Notes
• Wall wash kits are not available for IEM reflectors.
• For BAA/TAA wall wash option, add
"WW" to the reflector catalog (example:
TAA-HCD8TRCWW).
Trim Order Information
Accessories Order Information
Oversize Medium "Goof" Ring Type Finish
HCD8G = 8" Goof Ring for Medium Reflectors Round - 8.25" MIN ceiling opening 9.75" MAX ceiling opening, 10.75" OD
R = Round C = Specular Clear H = Haze (Semi-specular)
MW = Matte White (paintable) MB = Matte Black
HCD 8" Round Direct Mount Downlights & Wall Washers
PS51761324-8R page 4 February 11, 2026 11:20 AM https://www.cooperlighting.com/global/brands/wavelinx https://www.cooperlighting.com/global/brands/wavelinx
Product Specifications Emergency Battery Backup Options
| • | Available on HCDE Emergency Module Kits |
| • | Provide 90 minutes of standby egress lighting; |
consult national Life Safety Code and local code authority for specific requirements
• EM06 – 6-Watt self-test emergency battery with test switch
• EM14 – 14-W self-test emergency battery with test switch
| • | Self-Test (self-diagnostic) standard on models |
| • | Emergency test switch may be installed with |
included remote switchplate or integral in reflector
• Electrical box, as required, for remote switchplate by installer
• IEM reflector ordered separately
• IEM not available on HCD41T 4", Shallow-Wide round reflectors.
• HCD Module Kits are compatible with the Sure-Lites EBPLED family of Emergency Backup Batteries for field installation. Consult EBPLED specification sheet to determine appropriate Wattage.
LED
• Proximity phosphors over chip on board LEDs provide a uniform source with high efficiency and no pixilation
| • | LED is 90 CRI minimum, R9 greater than 50 |
| • | LED color uniformity & accuracy within 3-step SDCM |
at 2700K and 50000K and 4-step SDCM at 3000K, 3500K, & 4000K
• Lumen maintenance 80% at 60,000 hours (L80 / 60,000 hours)
Lumen and CCT Color Selection
• Lumen and CCT selection switches are on the module kit driver box.
• Field-select switch settings by installer accessed under galvanized steel hinged snap-latch cover that protects lumen and CCT settings yet allows for quick changes
| OR | |
| • | Factory ordered preset individual switch settings |
secure under galvanized steel fixed cover. Torx screw on cover secures presets yet allows for re-set access if needed. Factory label notes preset lumen and CCT. (See ordering information section for factory preset ordering codes.)
• 500/750/1000, 1500/2000/2500, 3000/3500/4000, 4000/4500/5000 field selectable lumens or factory preset lumen options
• 2700-3000-3500-4000-5000K field selectable CCT or factory preset CCT options
• Selectable lumen and CCT must be specified together, example: "LS510" lumen, "CS" CCT
• Factory preset lumen and CCT must be specified together, example: "L05" lumen, "935" CCT
Electronic Driver
| • | Integrated in module kit driver box |
| • | 120-277V 50/60 Hz constant current driver |
| • | Continuous dimming from 100% to 1% with 0 -10V |
analog dimming controls
| • | Dims to off after 1% level is reached |
| • | Compatible with WaveLinx and WaveLinx Lite |
Wireless dim-to-off functionality
Canada Electronic Driver Option (Available on HCDQC module kits only)
| • | 347VAC 50/60Hz constant current driver |
| • | Continuous dimming from 100% to 1%, with 0 -10V |
analog dimming controls
| • | Dims to off after 1% level is reached |
| • | 347VAC driver option available on HCDQC quick- |
connect module kits only
• 347V driver is not currently available with WaveLinx or WaveLinx Lite Wireless.
Reflectors
• Direct-mount feature of HCD4-6-8 series requires a precise ceiling cut-out for secure round & square reflectors for module kit retention. See technical data for ceiling cut-out sizes.
• Three lever clamps and a key-slot for accurate positioning and securing reflector to the LED engine
• Integral mousetrap springs on reflector secure assembly for direct-mount from below the finished ceiling
Medium Distribution Round Reflectors
• 4", 6", 8" round reflectors designed to fit all module kits
| • | Round spun aluminum |
| • | Available in specular and haze (semi-specular), |
matte white and matte black painted finishes.
Matte white is paintable (overpaint by others)
• Prismatic lensed wall-wash accessory kits for field installation, in round and square reflectors.
• Reflector optical design delivers medium 1.0 spacing criteria and 55 degree cutoff (nominal, field results may vary by aperture and finish)
| • | Deep regressed LED source for low glare, UGR < 19 |
| • | Round accessory goof rings cover ceiling |
irregularities
• Goof rings for medium reflectors available in specular and haze (semi-specular), matte white and matte black painted finishes. Matte white is paintable (overpaint by others)
Narrow Distribution Round Reflectors
| • | 4", 6", 8" round reflector designs fit all module kits |
| • | Narrow distribution dimensions equivalent to HALO |
Commercial HC series 41x-61x-81x reflectors, allowing use of HCD and HC series on the same job for consistent appearance
| • | Round spun aluminum |
| • | Available in specular and haze (semi-specular), |
matte white and matte black painted finishes.
Matte white is paintable (overpaint by others)
| • | Deep regressed LED source for low glare, UGR < 19 |
| • | Prismatic lensed wall-wash accessory kits for field |
installation
• Narrow reflector optical design delivers wide 0.7 spacing criteria and 50 degree cutoff (nominal, field results may vary by aperture and finish)
Wide (Shallow) Distribution Round Reflectors
• 4", 6", 8" round shallow reflector designs fit all module kits
• Ultra-shallow for installation in reduced plenum heights
• Wide distribution optical design delivers wide 1.28 spacing criteria and 65º+ cutoff (nominal, field results may vary by aperture and finish)
| • | Round spun aluminum |
| • | Available in specular and haze (semi-specular), |
matte white and matte black painted finishes.
Matte white is paintable (overpaint by others)
| • | Shallow regression of LED source, UGR < 23 |
| • | Shallow prismatic lensed wall-wash accessory kits |
6" and 8" for field installation (shallow wall wash not available in 4")
Compliance
• cULus damp and wet location listed, covered ceilings only and IP65 rated below the ceiling (IP64 with lensed wall wash accessory)
| • | Airtight per ASTM-E283 |
| • | IC listed LS510: 500, 750, 1000 lumen module |
kit - suitable for direct contact with air permeable insulation. IC models are also suitable for Non-IC installations. (Emergency battery module kits are not IC, Non-IC only)
• Non-IC listed LS1525: 1500-2000-2500 lumen, LS3040: 3000-3500-4000 lumen and LS4050:
4000-4500-5000 module kits. Insulation must be kept 3" from top and sides of luminaire.
• Marked spacing: 3000-3500-4000 lumen and 4000- 4500-5000 lumen are Non-IC AND require marked spacing.
| • | Center to Center Adjacent Luminaires = 36" |
| • | Center of Luminaire to Building = 18" |
| • | Minimum overhead = 0.5" |
• Not for use in direct contact with spray foam insulation, consult NEMA LSD57-2013
• Suitable for use in clothes closets when installed in accordance with the NEC 410.16 spacing requirements
• EMI/RFI emissions per FCC CFR Title 47 Part 15 Class A at 277V and Class B at 120V CAN ICES- 005(B)/NMB-005(B) at 120VAC and CAN ICES-005(A)/NMB-005(A) at 277VAC
| • | Contains no mercury or lead and RoHS compliant |
| • | Photometric testing per IES LM-79-08 |
| • | Photometric file format per IES LM-63-19 |
| • | Lumen maintenance projections per IES LM-80-08 |
and TM-21-11
• ENERGY STAR® reference Certified Light Fixtures database (not applicable: matte black reflectors, WaveLinx, and 347V module kits)
• 500-750-1000 lumen, ICAT models certified to State of California Title 24, JA8. Refer to MAEDBS Database JA8 High Efficacy LED Lighting
• All models may be used to comply with State of California Title 24 non-residential code as a dimmable LED luminaire
• BAA and TAA - product configurations with these designated prefixes are built to be compliant with the Buy American Act of 1933 (BAA) or Trade Agreements Act of 1979 (TAA), respectively. Please refer to Cooper Lighting Solutions DOMESTIC PREFERENCES website for more information.
BABA Domestic Preference Compliance
• FHWA and FTA agencies are utilizing their BAA rules for BABA compliance. Cooper’s products with a BAA designation are manufactured in the US and utilize a BAA COTS exemption rule for compliance. To verify a configured product with specific accessories and options meet BABA Domestic Preference Requirements; submit this catalog number to Cooper Lighting Quotation team for validation by our Engineering and Manufacturing teams.
This is the start of the file's text. The full file is on GovTribe.