This document is a presentation on wastewater thermal energy, highlighting the benefits and potential applications for the District of Columbia Water and Sewer Authority (DC Water). It provides an overview of DC Water's operations, the thermodynamics and efficiency of heat pumps, and the potential economic and environmental benefits of utilizing wastewater as a heat source. The presentation discusses DC Water's experience with wastewater thermal energy systems, including the DC Water Headquarters building and the covenant with the American Geophysical Union (AGU) for a wastewater thermal energy system. It also covers the potential scale and impact of wastewater thermal energy, as well as the organizational and regulatory considerations for district energy systems. The document includes references to additional resources and relevant legislation.
The related federal contract opportunity is a Request for Information (RFI) issued by the General Services Administration (GSA) Public Buildings Service regarding the Heating Operations and Transmission Division (HOTD) in Washington, DC. The RFI seeks industry feedback on various ownership and operational alternatives for the HOTD system, including privatization, to enhance the value, efficiency, and environmental impact of the heating and cooling services provided to the GSA's customer buildings. The RFI outlines the main objectives, such as identifying parts of the HOTD system that can be privatized cost-effectively, ensuring continued economical service, and reducing operating costs for the federal government while decarbonizing the distribution system.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Wastewater Thermal Energy
District of Columbia Water and Sewer Authority
Click to edit Master title styleDisclaimer
DC Water is a nonprofit governmental authority that acts in the interests of its ratepayers in the District of Columbia, Maryland, and Virginia.
DC Water does not endorse, recommend, or suggest use of any product or purchase from any vendor.
Information presented today reflects DC Water’s interest in the concepts of wastewater thermal energy and district energy and their potential value to our ratepayers, and DC Water’s analysis and experience to date.
Click to edit Master title styleDC Water
• One of nation’s largest utilities
• 1,200 employees
• $640 million annual operating budget
• 2.2 million people served
• 32 MW average power usage
• Drinking water purchased from Washington Aqueduct (USACE)
• Water distribution and wastewater collection for District of Columbia
• Wastewater treatment for DC region
• Independent, nonprofit governmental Authority – Act of Congress 1996
• Excellent performance record
Click to edit Master title styleDC Water Energized
Click to edit Master title styleWhy Wastewater Thermal?
1. Generate Revenue
Click to edit Master title styleThermodynamics and Heat Pumps
60˚F 80˚F 70˚F 70˚F
Final temperature depends on:
• Type of liquid (heat capacity)
• Volume in each chamber
• Initial temperature
60˚F 80˚F 40˚F 100˚F
Energy input
Energy input required depends on:
• Type of liquid
• Volume in second chamber
• Final temperature(s)
• Difference in initial temperatures
Click to edit Master title styleEfficiency of Heat Pumps power plant air-source heat pump heat from 20F outside air
Waste heat (dumped to environment)
1.0 0.5
0.5 electricity
Fuel - coal
1.5
1.0 power plant air-source heat pump heat from 20F outside air
Waste heat
1.0 0.5
0.5 electricity
Fuel – natural gas
1.25
0.75 power plant ground-source heat pump heat from 50F underground
Waste heat
1.0 0.25
0.75 electricity
Fuel – natural gas
0.6
0.35 power plant electric heater
Waste heat
1.0 1.0 electricity
Fuel – natural gas
2.5
1.5 power plant
WWTE
heat pump heat from 60F wastewater
Waste heat
1.0 0.2
0.8 electricity
Fuel – natural gas
0.5
0.3
Natural gas furnace
1.0
Fuel – natural gas
1.25
Waste heat lost to atmosphere
0.25
How much fuel is needed to deliver 1 unit of heat to a building?
Click to edit Master title stylePotential Benefits
Economic
• No furnace, no cooling tower
• High efficiency heat transfer: COP up to 8
• Operational savings of up to 80%
Environmental
• Reduced energy consumption
• Switch from direct-fossil-fired to electric grid for heat
• Eliminates consumptive fresh water use for cooling
Development
• Rooftop space: extra apartments, pool, etc.
• Simplified maintenance
Click to edit Master title styleHow It Works
Heat exchanger
Heat exchanger
Schematic credit: Pozzi Leopoldo srl
Click to edit Master title styleWastewater Thermal Energy – Buildings in Operation
Photo credits: American Geophysical Union, DC Water
American Geophysical Union
DC Water Headquarters
Click to edit Master title styleDC Water – AGU Covenant
Attached to Property
• Will survive transfer or sale
• Allows connection to sewer main
• 20 year duration
• Maintenance: all at AGU’s cost; DC Water will keep inlet open
DC Water
• Access to sewage
• No redesign of sewage system to reduce flow
• Resumption of flow as fast as possible in event of disruption
• No upstream connections with negative impact
AGU
• Submit all design, construction, and operational plans for approval
• Operate system only within parameters submitted
• No inlet or outlet of material (closed system)
• No disruption of flow in main
Click to edit Master title styleDC Water Headquarters
• Completed 2018
• Houses admin/public functions of DC Water
• Built on top of sewage pump station
• 150,000 square feet
Click to edit Master title styleHQO Efficiency
Design choices cut energy cost in half from already energy-efficient code requirements
With wastewater as the heat source/sink, energy cost dropped an additional 29%
And- the building could be fully electrified even where a geothermal field was impossible
Click to edit Master title styleResource Size
F
Each 1,000,000 gallons/day yields ~1 MW thermal energy which equals
100 MW for each 1,000,000 people
In DC, that’s 200 MW, or at least 25,000,000 square feet of conditioning
Plus, potentially more energy at the treatment plant – up to 3-4x
Click to edit Master title styleImpact of Rain and Snow
Click to edit Master title styleDistrict Energy
Click to edit Master title styleAdvantages of District Energy
• Reduced necessary capacity due to noncoincident peak loads
• Easier integration of thermal storage
• Capture of reverse-season sources (eg, datacenters)
• Shoulder-season thermal circulation
• Easier integration of renewables
• No need to match supply and demand at each point
• Professional operators
• Professional maintenance
• Reduced in-building equipment frees space
Click to edit Master title styleOrganizational Elements
• Who pays for, builds, and owns the central system?
• DC Water
• Developer/developer instrument
• Third-party
• Who operates and maintains the system?
• DC Water can, but doesn’t have to
• What regulations would apply?
• What is the legal relationship between the properties and the system?
• DOEE and PSC views
Click to edit Master title styleWastewater Thermal Energy – To The Future
Maryland made wastewater thermal energy eligible for renewable energy credits in 2021.
In Denver, a 250-acre development will get 90% of its thermal energy from the sewer underneath.
King County, Washington is working with private partners to develop WWTE systems.
Valsana Hotel in Arosa, Switzerland uses a combination of wastewater and geothermal for 100% of its heat.
SE False Creek, in Vancouver, Canada, is an entire neighborhood heated by wastewater.
Photo credits: Valsana and New York Times
Click to edit Master title styleAdditional Resources and References
• Water Research Foundation 4788: State of the Science and Issues Related to Heat Recovery from Wastewater (2019)
• Water Research Foundation 4843: Integrating Sewage Thermal Energy Use (STEU) and Other Emerging Water-Energy-Waste Technologies into Decentralized/Distributed Systems (2022)
• Denver projects: Jim McQuarrie (Jim.McQuarrie@tetratech.com)
• City of Philadelphia: Paul Kohl (Paul.Kohl@Phila.gov)
• HQO Design: Don Posson (Don.Posson@smithgroup.com)
• RPS Legislation: D.C. Act 21-466 (2016), Maryland HB0561 (2021)
• DC Public Service Commission RFP No. PSC-22-06 (proposals in review)
• International District Energy Association (www.districtenergy.org)
Click to edit Master title style
Q&A
Saul Kinter
Business Development Program Manager Department of Resource Recovery
DC Water saul.kinter@dcwater.com
| Slide 1 |
| Slide 2: Disclaimer |
| Slide 3: DC Water |
| Slide 4: DC Water Energized |
| Slide 5: Why Wastewater Thermal? |
| Slide 6: Thermodynamics and Heat Pumps |
| Slide 7: Efficiency of Heat Pumps |
| Slide 8: Potential Benefits |
| Slide 9: How It Works |
| Slide 10: Wastewater Thermal Energy – Buildings in Operation |
| Slide 11: DC Water – AGU Covenant |
| Slide 12: DC Water Headquarters |
| Slide 13: HQO Efficiency |
| Slide 14: Resource Size |
| Slide 15: Impact of Rain and Snow |
| Slide 16: District Energy |
| Slide 17: Advantages of District Energy |
| Slide 18: Organizational Elements |
| Slide 19: Wastewater Thermal Energy – To The Future |
| Slide 20: Additional Resources and References |