D1. RFQ PWS Attachment 1 NREA.pdf
PDF 191 KB Posted
- Attached to
- Laboratory Testing Services
- Solicitation number
- M0026426Q0053
- Issued by
-
United States Marine Corps
About this file
This is a Performance Work Statement (PWS) Attachment for United States Marine Corps Laboratory Testing Support Services dated 17 February 2026.
The contractor shall provide comprehensive drinking water testing and sampling services for Marine Corps Base (MCB) Quantico, VA. Services are classified as essential contractor services requiring on-site performance with no telework authorization per DFARS 252.237-7023(b). The contractor must furnish all sample containers and conduct analysis of water samples collected from a central collection site within a 15-mile radius of MCB Quantico or directly from the Mainside Water Treatment Plant, with collection occurring by 2:00 PM on a varying schedule. The contractor must transport and analyze bacteriological samples within the required six-hour hold time. Testing requirements for the Mainside Drinking Water Treatment Plant include 22 distinct analysis types, ranging from carbamate and cyanide detection to PFAS analysis using EPA Methods 533 and 537.1, with specific sampling frequencies noted (e.g., 20 monthly samples from Mainside, 1 from Upshur, and 10 from Camp Barrett for coliform testing). All sample containers must be delivered to 1303 Caddy Road, MCB Quantico, VA 22134. The contractor must provide sample analysis capability seven days per week, 52 weeks annually, while maintaining all sample hold times and delivering test results within seven days of analysis. The contractor is required to report any test abnormalities to the Contracting Officer's Representative and the Water Treatment Plant on the same day results become available.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| E1. Solicitation Amendment M0026426Q00530001.pdf | ||
| D1. RFQ Attachment 1 Q_A.xlsx | XLSX spreadsheet | |
| D1. RFQ Attachment 2a Past Perf Questionnaire.docx | DOCX document | |
| D1. PWS.pdf | ||
| D1. Solicitation - M0026426Q0053_Redacted.pdf | ||
| D1. RFQ Attachment 3 Price Workbook.xlsx | XLSX spreadsheet | |
| D1. RFQ Attachment 2 Past Performance.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Dated: 17 February 2026
DISTRIBUTION: DoD
COMMUNITY ONLY
United States Marine Corps (USMC)
Laboratory Testing Support Services
PWS Attachment 1
Accordance with DFARS 252.237-7023(b), the below identified contractor services performed under this contract are essential contractor services in support of mission essential functions.
These services are required to be performed on-site to support minimum sustainment of drinking water operations; telework is not authorized:
PWS 3.2.3 Drinking Water Program
3.2.3.1 The Contractor shall furnish all sample containers and analyze all samples required for testing/sampling aboard Marine Corps Base (MCB), Quantico, VA. Testing frequency shall follow the appropriate regulation requirement.
PWS 3.3.2 Drinking Water Samples Collection Parameters
The contractor shall collect the water samples from a central collection site within a 15-mile radius of MCB, Quantico, VA, or from the Mainside Water Treatment Plant MCB, Quantico, by 2:00 PM on a varying schedule to be arranged by both parties. The contractor shall be prepared to transport and analyze bacteriological water samples within the six (6) hour hold time allowed.
3.3.2.1 Mainside Drinking Water Treatment Plant
a. Carbamate by EPA method 531 (CARB)
b. Cyanide (CYN3)
c. Diquat by EPA Method 549
d. Fluoride
e. Fumigants by EPA Method 551.3
f. Halo-Acetic Acids by EPA 552.2
g. Herbicide by EPA 515
h. Inorganic Chemicals in Drinking Water
i. Lead and Copper ( to include two
(2) additional lead samples per month for in house data monitoring)
j. Metal Analysis of Drinking Water
k. Nitrate-acid preserved sample(NN)
l. Radiological
m. Semi-volatiles by EPA method 525.2
n. Total coliform and E-coli by Quanti-Tray
o. Total coliform Presence absence (Current drinking water permits call for 20 samples from Mainside, Dated: 17 February 2026
DISTRIBUTION: DoD
COMMUNITY ONLY
One (1) sample from Upshur and ten (10) samples from Camp Barrett each month; also allow for possible positive results/resampling ~ five
(5) additional samples per month.)
p. Total Organic Carbon
q. Total Organic Carbon and alkalinity
r. Trihalomethanes
s. Volatile Organics by method 524
t. Disinfection by-products;
a. TTHM (to include 6 compliance samples, and 2 in house samples for data monitoring per quarter)
b. HAA5 (to include 6 compliance samples, and 2 in house samples for data monitoring per quarter)
u. Pesticides DW – SUB (4)
v. PFAS, EPA Method 533 and EPA Method 537.1
(Per DoD Memo for all four (4) finished water systems, to include quarterly compliance sampling and 2 additional in-house samples for data monitoring annually)
3.3.2.2 All sample containers shall be delivered to the Water Treatment Plant, 1303 Caddy Road, MCB, Quantico, VA 22134.
3.3.2.3 The contractor shall be capable to provide sample analysis seven (7) days per week, 52 weeks per year, all while keeping within all sample hold times.
3.3.2.4 The contractor shall ensure that test results are provided on time, within a seven (7) day response period. The contractor must report test abnormalities to the Contracting Officer’s Representative (COR) and Plant the same day the information is available to the lab.
End
File details come from the government source that posted it. Updated .